下载:  下载PDF数据表文档文件
Honeywell Pressure Switches  
50094081  
HP, HE, MH, ME, LP, LE, 5000, and 1000 Series  
Issue 5  
Datasheet  
DESCRIPTION  
FEATURES  
The Honeywell Pressure Switch portfolio consists of:  
• High Pressure (HE/HP Series)  
• Medium Pressure (ME/MH Series)  
• Low Pressure (LE/LP Series)  
• 5000 Series, 1000 Series  
• Pressure switching set point range: 3.5 psi to 4500 psi  
• Proof pressure: from 500 psi up to 10,000 psi  
• Burst pressure: from 1250 psi up to 20,000 psi  
• Life cycle rating up to 2 million  
• IP67 sealing rating4  
• Operating temperature: -40 °C to 120 °C [-40 °F to 248 °F]  
• Hysteresis option5  
These pressure switches are durable, reliable  
electromechanical gauge pressure on/off switches that are  
available with either single pole single throw (SPST) normally  
open or normally closed circuitry, or single pole double throw  
(SPDT) circuitry. Their high proof pressure and burst pressure  
ratings can allow for use in many rugged applications that  
require the making or breaking of an electrical connection in  
response to a pressure change of the system media.  
• More than 15 pressure port options and over 30 electrical  
terminations  
• Plated steel, brass or stainless steel options3  
• Switching point accuracy up to 2 ꢀ  
POTENTIAL APPLICATIONS  
DIFFERENTIATION  
Through optional smart diagnostic technology,  
Honeywell pressure switches are able to detect failures  
such as open circuits, cut wires, worn insulation, and  
more6  
• Optional smart diagnostic technology allows up to four  
segregated signal amplitudes to perform diagnostics and  
status6  
• Pressure port snubber suppresses pressure spikes2  
• IP67 sealing provides enhanced durability in harsh  
environmental and washing applications1  
• Agricultural machinery  
• Heavy duty construction  
machinery and trucks  
• Lawn & garden machinery  
• Marine vessels  
• Material handling  
machinery  
• Railway  
• CNC machines  
• Compressors/boilers  
• Fracking equipment  
• Food & beverage equipment  
• Generators  
• HVAC/R equipment  
• Mud pumps  
• Pneumatic equipment  
• Presses/punches  
• Pressure washers  
• Trash compactors  
• Water pumps & jet cutting  
machines  
VALUE TO CUSTOMERS  
• Designed to provide resistance to corrosion and enhances  
equipment life with available two million life cycle rating and  
IP67 rating1  
• Can expedite design and product cycle due to ability to  
receive samples in two weeks and production units in four  
weeks  
• Can reduce tooling, service, and manufacturing labor costs  
due to standard connections, extended product life, and  
expedited design and production cycle  
PORTFOLIO  
Honeywell also offers the PBN1 Series and PBN3 Series  
Pressure Sensor.  
1 HP, HE, MH, ME, LP, LE Series  
2 HP, HE Series  
3 ME, MH, LP, LE Series  
4 HP, HE, LP, LE, ME Series  
5 HP, HE, LP Series  
6 HP, HE, ME, LP, LE Series  
Safety and Productivity Solutions  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
Table 1. Specifications  
Character-  
istic  
HP Series  
HE Series  
ME Series  
MH Series  
LP Series  
LE Series  
5000 Series 1000 Series  
Product  
length (various  
terminations)  
see pages 5 and 6  
see page 5  
see page 8  
see page 7  
see page 9  
see page 9  
see page 10  
Product length  
(blade)  
Product length  
(#8-32 screws)  
Product length  
(Metripack)  
58,42 mm  
[2.3 in]  
60,96 mm  
[2.4 in]  
73,66 mm  
[2.9 in]  
65,6 mm  
see pages 5 and 6  
see pages 5 and 6  
see pages 5 and 6  
27 mm  
see page 5  
see page 5  
see page 5  
27 mm  
see page 8  
see page 8  
see page 8  
27 mm  
see page 7  
see page 7  
see page 7  
27 mm  
see page 9  
see page 9  
see page 9  
27 mm  
see page 9  
see page 9  
see page 9  
27 mm  
[2.583 in]  
0.50 in (steel)  
0.437 in (brass)  
M10 x 1.25 banjo  
fitting  
Hex size  
Ease of  
18 mm open  
spanner  
box spanner  
yes  
box spanner  
yes  
box spanner  
no  
box spanner  
no  
box spanner  
yes  
box spanner  
no  
1/2 in open spanner  
installation  
Snapꢁaction  
switch  
Set point1  
range  
Set point  
ranges  
no  
no  
10 psi to 60 psi  
[0,69 bar to 2,7 bar]  
100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi  
6 (Base Style A)  
40 psi to 500 psi  
4
3.5 psi to 150 psi  
4
3.5 psi to 150 psi  
4
75 psi to 150 psi  
8
6
4
7 (Base Style B)  
0.5 psi to 1 psi  
( 0.3 psi)ꢁ  
40 psi to 70 psi  
( 7 psi)ꢁ  
1.1 psi to 3 psi  
( 0.5 psi)ꢁ  
25 psi to 50 psi  
( 3 psi)ꢁ  
100 psi to 150 psi 150 psi to 1000 psi  
>70 psi to 130 psi  
( 10 psi)ꢁ  
3.1 psi to 7 psi  
( 1 psi)ꢁ  
( 10 ꢀ)ꢁ  
150 psi to 500 psi  
( 6 ꢀ)ꢁ  
( 14ꢀ)ꢁ  
1000 psi to  
2000 psi  
>50 psi to 100 psi  
( 7 psi)ꢁ  
Set point  
accuracy  
@ 25 °C  
>130 psi to 200 psi  
( 15 psi)ꢁ  
3.5 psi to 10 psi ( 1 psi)ꢁ  
8 psi to 13 psi  
( 2 psi)ꢁ  
20 psi 10 psiꢁ  
58 psi 20 psi  
>100 psi to 150 psi  
( 10 psi)ꢁ  
>10 psi to 50 psi ( 3 psi)ꢁ  
>50 psi to 100 psi ( 7 psi)ꢁ  
>100 psi to 150 psi ( 10 psi)  
501 psi to 4000 psi  
( 3.5 ꢀ)ꢁ  
( 12 ꢀ)ꢁ  
>200 psi to 280 psi  
( 20 psi)ꢁ  
14 psi to 24 psi  
( 3 psi)ꢁ  
2000 psi to  
4000 psi  
( 11 ꢀ)ꢁ  
(before test)  
>150 psi to 250 psi  
( 13 psi)ꢁ  
4000 psi to 4500  
psi  
>280 psi to 350 psi  
( 30 psi)ꢁ  
25 psi to 50 psi  
( 5 psi)ꢁ  
>250 psi to 350 psi  
( 16 psi)  
( 2 ꢀ)  
>4000 psi ( 10 ꢀ)  
>350 psi to 500 psi  
( 40 psi)  
51 psi to 90 psi  
( 7 psi)ꢁ  
91 psi to 150 psi  
( 10 psi)  
0.5 psi to 3 psi  
( 1.5 psi)ꢁ  
40 psi to 70 psi  
( 6 psi)ꢁ  
25 psi to 50 psi  
(20 psi)ꢁ  
4 psi to 7 psi  
( 2.5 psi)ꢁ  
>70 psi to 130 psi  
( 10 psi)ꢁ  
3.5 psi to 10 psi  
>50 psi to 100 psi  
(30 psi)ꢁ  
( 2.8 psi)ꢁ  
>10 psi to 50 psi  
( 14 psi)ꢁ  
8 psi to 13 psi  
( 3.5 psi)ꢁ  
>130 psi to 200 psi  
( 15 psi)ꢁ  
Average deadꢁ  
band max.  
>100 psi to 150 psi  
(40 psi)ꢁ  
14 psi to 24 psi  
( 8 psi)ꢁ  
n/a  
n/a  
n/a  
n/a  
>200 psi to 280 psi  
( 20 psi)ꢁ  
>50 psi to 100 psi  
( 38 psi)ꢁ  
>100 psi to 150 psi  
( 40 psi)  
>150 psi to 250 psi  
(50 psi)ꢁ  
25 psi to 50 psi  
( 15 psi)ꢁ  
>280 psi to 350 psi  
( 30 psi)ꢁ  
>250 psi to 350 psi  
(60 psi)  
51 psi to 90 psi  
( 23 psi)ꢁ  
>350 psi to 500 psi  
( 40 psi)  
91 psi to 150 psi  
( 40 psi)  
Operating  
pressure2  
1400 psi  
5,000 psi max.  
5,000 psi max.  
500 psi max.  
4,000 psi  
600 psi max.  
6,000 psi  
250 psi max.  
500 psi  
250 psi max.  
500 psi  
150 psi, 250 psi  
[96,5 bar] max.  
10,000 psi (Base  
Style A)  
6,500 psi (Base  
Style B)  
2973 psi  
[205 bar]  
Proof pressure3  
Hysteresis  
10,000 psi  
500 psi  
5 ꢀ to 55 ꢀ  
3 ꢀ to 65 ꢀ  
5 ꢀ to 55 ꢀ  
(based on set point  
range)  
(based on set point (based on set point  
n/a  
n/a  
n/a  
n/a  
n/a  
range)  
range)  
20,000 psi (Base  
3500 psi  
[241 bar]  
Burst pressure4 Style A)ꢁ 9,000 psi  
20,000 psi  
8,000 psi  
9,000 psi  
1250 psi  
1250 psi  
4000 psi  
(Base Style B)  
15 A, 6 Vdcꢁ  
8 A, 12 Vdcꢁ  
4 A, 24 Vdc  
Current rating  
(resistive)  
5 A at 250 Vac  
5 A at 24 Vdc  
3 A at 250 Vac  
3 A at 24 Vdc  
7.5 mA to 3 A,  
7.5 mA to 5 A,  
7.5 mA to 3 A,  
12 Vdc with two-  
100 mA to 3 A max.  
n/a  
24 Vdc and 250 Vac  
24 Vdc and 250 Vac 24 Vdc and 250 Vac  
1157 bulbs (4.4 A)  
Current rating  
(inductive)  
5 A at 115 Vac (SX  
rating)ꢁ 3 A at 28 Vdc  
1 A, 120 Vac  
0.5 A, 240 Vac  
n/a  
n/a  
1 A at 28 Vdc  
n/a  
n/a  
8Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.  
Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.  
Port Styles A, B, E, M, P, T, and Y will use Base Style B.  
Switches less than 150 psi will only use Base Style B.  
2
sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
Character-  
istic  
HP Series  
HE Series  
ME Series  
MH Series  
LP Series  
LE Series  
5000 Series 1000 Series  
Rated thermal  
current  
5 A  
3 A  
3 A  
n/a  
n/a  
5 A  
3 A  
n/a  
n/a  
n/a  
n/a  
Rated insulaꢁ  
tion voltage  
28 V  
28 V  
28 V  
28 V  
28 V  
Shortꢁcircuit  
protective  
Class J fuse (10 A, 600 V)  
1000 A  
n/a  
Class J fuse (10 A, 600 V)  
n/a  
n/a  
device cꢁtype  
max. rating  
Conditional  
short circuit  
current  
n/a  
n/a  
1000 A  
1000 A  
n/a  
n/a  
n/a  
n/a  
Pollution  
degree  
3 (macro environment)  
ꢂ40 °C to 85 °C  
3 (macro environment)  
Temperature  
rating  
ꢂ40 °C to 120 °C  
ꢂ40 °C to 121 °C  
[ꢂ40 °F to 250 °F]  
ꢂ20 °C to 74 °C  
[ꢂ4 °F to 165 °F]  
ꢂ40 °C to 120 °C [ꢂ40 °F to 248 °F]  
[ꢂ40 °F to 248 °F] [ꢂ40 °F to 185 °F]  
Media  
connection  
multiple ports  
available  
multiple ports  
available  
1/8ꢂ27 NPT male  
thread  
multiple ports  
available  
multiple ports available  
A = 1/4ꢂ18 NPT  
A = 1/4ꢂ18 NPT  
B = 1/8ꢂ27 NPT  
C = 1/2ꢂ20 UNF  
D = 1/8ꢂ27 PTF  
E = M12 × 1.5  
B = 1/8ꢂ27 NPT  
C = 1/2ꢂ20 UNF  
D = 1/8ꢂ27 PTF  
E = M12 × 1.5  
A = 1/4ꢂ18 NPT  
B = 1/8ꢂ27 NPT  
C = 1/2ꢂ20 UNF  
D = 1/8ꢂ27 PTF  
E = M12 × 1.5  
A = 1/4ꢂ18 NPT  
B = 1/8ꢂ27 NPT  
C = 1/2ꢂ20 UNF  
D = 1/8ꢂ27 PTF  
E = M12 × 1.5  
F = M14 × 1.5  
C = 1/2ꢂ20 UNF  
F = M14 × 1.5  
F = M14 × 1.5  
G = 9/16ꢂ18 UNF  
H = 3/4ꢂ16 UNF  
J = G1/8 BSPP  
L = 3/8ꢂ24 UNF  
F = M14 × 1.5  
F = M14 × 1.5  
M10 x 1.25 double  
banjoꢁ  
Refer to product  
G = 9/16ꢂ18 UNF  
H = 3/4ꢂ16 UNF  
J = G1/8 BSPP  
G = 9/16ꢂ18 UNF  
H = 3/4ꢂ16 UNF  
J = G1/8 BSPP  
G = 9/16ꢂ18 UNF  
H = 3/4ꢂ16 UNF  
J = G1/8 BSPP  
G =9/16ꢂ18 UNF  
H = 3/4ꢂ16 UNF  
K = M18 × 1.5  
Pressure ports nomenclature for  
1/8ꢂ27 NPT  
M10 x 1ꢁ  
pressure port types.  
1/8ꢂ27 NPT  
M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF M = 7/16ꢂ20 UNF  
N = 7/8ꢂ14 UNF  
R = R1/8 BSPT  
T = M10 × 1.0  
V = R1/2 BSPT  
Y = G1/4 BSPP  
Z = R1/4 BSPT  
P = 1/2ꢂ14 NPT  
R = R1/8 BSPT  
T = M10 × 1.0  
V = R1/2 BSPT  
Y = G1/4 BSPP  
Z = R1/4 BSPT  
R = R1/8 BSPT  
T = M10 × 1.0  
V = R1/2 BSPT  
Y = G1/4 BSPP  
Z = R1/4 BSPT  
R = R1/8 BSPT  
T = M10 × 1.0  
V = R1/2 BSPT  
Y = G1/4 BSPP  
Z = R1/4 BSPT  
Circuit forms5  
SPDT, SPST - NO/NC  
SPDT, SPST - NO/NC  
SPST - NO/NC  
SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPSTꢂNOꢁ SPSTꢂNC  
SPNO  
Smart pressure  
single- or dual-resistor topology available  
single- or dual-resistor topology available  
2 million (Base A)  
1 million (Base B)  
Life  
1 million  
1 million  
1 million  
2 million  
1 million  
100,000 cycles  
100,000 cycles  
Agency approvꢁ  
als (special use  
switches)  
UL Custom  
(select models)  
Agency approvꢁ  
als (other)  
CE  
no  
CE  
CE  
CE  
CE  
CE  
Field  
no  
yes  
no  
yes  
no  
yes  
no  
yes  
no  
yes  
no  
no  
no  
adjustability6  
Spike  
dampening  
yes  
yes  
IP67 (connecetors)  
IP67 (connectors)  
IP67 (wire out)  
IP00 (blade/screw)  
IP67 (connectors)  
IP67 (wire out)  
IP67 (connectors)  
IP67 (wire out)  
Ingress  
IP67 (wire/Base A) IP67 (connectors)  
IP69K (wire/Base B) IP00 (blade/screw)  
IP00 (blade/screw)  
IP67 (connectors)  
IP00 (blade/screw)  
IP00  
IP65  
protection7  
IP00 (blade/screw) IP00 (blade/screw)  
Vibration  
resistance  
swept sine: 10 Hz to 2000 Hz at 15 g, 20 min/sweepꢁ 8 hours in each axis  
random: 5 Hz to 2000 Hz, 8 hours/axisꢁ 14,88 gꢂRMS, each axis  
Shock  
500 m/sec2, 11 mSEC, 100 shocks / axis  
500 m/sec2, 11 mSEC  
15 G @ 5 mSEC  
EPDM  
resistance  
Wetted part  
(diaphragm)  
Kapton®  
Kapton®  
n/a  
Nitrile/EPDM/LTNB  
Tefzel®  
Polymide film  
(Teflon® coated)  
(Teflon® coated)  
Wetted part  
(piston)  
nitrile or EPDM  
o-ring  
nitrile or EPDM  
o-ring  
nitrile or EPDM  
o-ring  
nitrile or EPDM  
o-ring  
nitrile or EPDM  
o-ring  
nitrile o-ring, steel piston  
EPDM  
133 g [4.7 oz] (Base Style A)  
178 g [6.28 oz] (Base Style B)  
Weight  
53 g [1.9 oz]  
gold plated  
53 g [1.9 oz]  
gold plated  
58 g [2.0 oz]  
gold plated  
53 g [1.9 oz]  
gold plated  
65 g [2.3 oz]  
40 g [1.4 oz]  
Contacts  
silver / gold inlay  
silver  
silver-plated copper silver-plated copper  
Rynite 545 glass  
glass reinforced  
filled (housing)ꢁ  
Product finish  
zinc plating  
zinc plating  
zinc plating  
zinc plating  
zinc plating  
zinc plating  
polyester (housing)ꢁ  
Travalent plated steel  
plated steel (base)  
(base)  
1Set point: Point at which switch actuates or deꢁactuates  
2Operating pressure: Maximum normal system operating pressure  
3Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable.  
4Burst pressure: Point of complete switch failure  
5SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed.  
6Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations.  
7IP00 for AA and BA terminations.  
Safety and Productivity Solutions  
3
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
Table 2. Terminations  
Series  
Available Terminations  
AA = Spade Terminals  
BA = Screw Terminals  
CA = Deutsch DT04-3P-E005 (3-Pin Connector)  
DA = Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector)  
EA = 10ꢁinch Cable, 18 AWG (Wire Out, No Connector)  
FA = 10ꢁinch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*  
GA = 10ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector) (18 AWG)*  
HA = 10ꢁinch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*  
JA = 10ꢁinch Cable w/Din43650-C (3-Pin Connector) (18 AWG)*  
KA = 10ꢁinch Cable w/M12x1 (Brad Harrison Micro) ꢁ 21032121306 Harting P/N (3-Pin Connector) (18 AWG)*  
LA = 10ꢁinch Cable w/Packard Weatherpack Male Terminal ꢁ 12020827 (3-Pin Connector) (18 AWG)*  
MA = 10ꢁinch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)  
NA = 3ꢁinch Cable w/Packard 2P Tower Connector ꢁ 12015792 (2-Pin Connector) (18 AWG)  
PA = 2.75ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (18 AWG)  
RA = 4ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (16 AWG)  
SA = 5.5ꢁinch Cable w/ITT Cannon 2P Sure-Seal Circular Connector ꢁ SS2R-120-1804-000 (2-Pin Connector) (18 AWG)  
TA = 8.5ꢁinch Cable w/ITT Cannon 3P Sure-Seal Circular Connector ꢁ SS3R-120-8551-001 (3-Pin Connector) (16 AWG)*  
UA = 10ꢁinch Cable ꢁ Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)*  
VA = 10ꢁinch Cable ꢁ Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)*  
WA = 4.5ꢁinch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*  
HP, HE, ME,  
LP, LE  
XA = 10ꢁinch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)  
YA = 6ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282104-1 (2-Pin Connector) (18 AWG)*  
ZA = 10ꢁinch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)  
AB = Deutsch DT04-2P-E005 (2-Pin Connector)  
BB = 10ꢁinch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)*  
CB = 6ꢁinch Cable w/ AMP Super Seal 1.5 ꢁ 282080-1 (2-Pin Connector) (18 AWG)  
DB = 10ꢁinch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*  
EB = 4.5ꢁinch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)  
FB = 10ꢁinch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)  
GB = 8.5ꢁinch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)  
AA = Spade Terminals  
BA = Screw Terminals  
DA = Amp Super Seal 1.5 ꢁ 282105-1 (3-Pin Connector)  
EA = 10ꢁinch Cable, 18 AWG (Wire Out, No Connector)  
HA = 10ꢁinch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)*  
MA = 10ꢁinch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG)  
NA = 3ꢁinch Cable w/Packard 2P Tower Connector ꢁ 12015792 (2-Pin Connector) (18 AWG)  
PA = 2.75ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (18 AWG)  
RA = 4ꢁinch Cable w/Packard 2P Shroud Connector ꢁ 12010973 (2-Pin Connector) (16 AWG)  
SA = 5.5ꢁinch Cable w/ITT Cannon 2P Sure-Seal Circular Connector ꢁ SS2R-120-1804-000 (2-Pin Connector) (18 AWG)  
WA = 4.5ꢁinch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)*  
XA = 10ꢁinch Cable w/ Metripack 2-Pin Shroud Connector 153000027 (18 AWG)  
YA = 6ꢁinch Cable w/Amp Super Seal 1.5 ꢁ 282104-1 (2-Pin Connector) (18 AWG)*  
ZA = 10ꢁinch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG)  
AB = Deutsch DT04-2P-E005 (2-Pin Connector)  
MH  
CB = 6ꢁinch Cable w/ AMP Super Seal 1.5 ꢁ 282080-1 (2-Pin Connector) (18 AWG)  
DB = 10ꢁinch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)*  
EB = 4.5ꢁinch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG)  
FB = 10ꢁinch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG)  
*These connectors are designed for dual circuit (SPDT) by default. They can be used for singleꢁcircuit applications (SPNC/SPNO) by making suitꢁ  
able connections. Refer to wiring diagram.  
4
sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ HIGH PRESSURE: HP SERIES (BASE STYLE A), HE SERIES  
Base Style A key specifications • Life: 2 million (HP), 1 million (HE); Burst pressure: 20,000 psi  
Figure 1. AMP Superseal 1.5  
20,02 mm  
61,64 mm  
[2.427 in]  
[0.788 in]  
27 mm  
[1.063] hex A/F  
(bottom view)  
(top view)  
Female Connector Part Number (included): Cꢂ282105  
Male Mating Connector (customer provided): Cꢂ282087  
IP Rating: IP67  
Figure 2. Deutsch  
61,64 mm  
[2.427 in]  
21,16 mm  
[0.833 in]  
27 mm  
[1.063] hex A/F  
(bottom view)  
(top view)  
Female Connector Part Number (included): DT04ꢂ3P  
Male Mating Connector (customer provided): DT06ꢂ3S  
IP Rating: IP67  
Figure 3. Spade Terminal  
27 mm  
61,64 mm  
[2.427 in]  
14,43 mm  
[0.568 in]  
[1.063] hex A/F  
(bottom view)  
(top view)  
Figure 4. Screw Terminal  
61,64 mm  
[2.427 in]  
12,65 mm  
[0.498 in]  
27 mm  
[1.063] hex A/F  
(bottom view)  
(top view)  
Figure 5. Cable  
61,64 mm  
[2.427 in]  
19,51 mm  
[0.768 in]  
27 mm  
[1.063] hex A/F  
(bottom view)  
(top view)  
IP Rating: IP67  
Safety and Productivity Solutions  
5
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ HIGH PRESSURE: HP SERIES (BASE STYLE B)  
Base Style B key specifications • Life: 1 million; Burst pressure: 9,000 psi  
Figure 6. HP Series Base Style B  
71,47 mm  
[2.814 in]  
14,43 mm  
[0.568 in]  
HP with smaller port: dimension 2.814 in remains same  
(bottom view)  
for all base ports.  
Figure 7. HP Series Pressure Port Dimensions  
“H”  
Thread  
“H”  
Thread  
“Ø D”  
“Ø D”  
“A”  
“H”  
Thread  
“Ø D”  
“Ø C”  
Table 3. HP/HE Series Pressure Port Diameters and Heights  
Nomenclature Code  
Thread  
7/16-20 UNF  
1/2-20 UNF  
9/16-18 UNF  
3/4-16 UNF  
7/8-14 UNF  
M10 x 1.0  
Height “A”  
Diameter “ØD”  
9,25 mm [0.364 in]  
10,85 mm [0.427 in]  
12,24 mm [0.482 in]  
16,74 mm [0.66 in]  
19,6 mm [0.773 in]  
9,25 mm [0.364 in]  
10,85 mm [0.427 in]  
12,24 mm [0.482 in]  
16,74 mm [0.66 in]  
10,29 mm [0.405 in]  
13,72 mm [0.540 in]  
Diameter “ØC”  
Height “H”  
11 mm [0.433 in]  
11 mm [0.433 in]  
12 mm [0.472 in]  
14 mm [0.551 in]  
16 mm [0.630 in]  
11 mm [0.433 in]  
11 mm [0.433 in]  
12 mm [0.472 in]  
14 mm [0.551 in]  
12,497 mm [0.492 in]  
17,63 mm [0.694 in]  
M
C1  
G2  
H
N
T
1,60 mm [0.063 in]  
2,48 mm [0.098 in]  
2,48 mm [0.098 in]  
2,48 mm [0.098 in]  
13,79 mm [0.543 in]  
16,79 mm [0.661 in]  
18,8 mm [0.74 in]  
23,8 mm [0.937 in]  
E
F2  
M12 x 1.5  
M14 x 1.5  
K
M18 x 1.5  
B
1/8-27 NPT  
1/4-18 NPT  
A
1Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.  
2Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.  
Switches less than 150 psi will use only Base Style B.  
6
sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ MEDIUM PRESSURE: MH SERIES  
Figure 8. AMP Superseal 1.5  
Figure 13. MH Series Pressure Port Dimensions  
67,06 mm max.  
[2.64 in] max.  
(bottom view)  
Figure 9. Deutsch 2-pin  
“A”  
67,06 mm max.  
[2.64 in] max.  
Table 4. MH Series Pressure Port Diameters and Heights  
(bottom view)  
Port  
Diameter “ØD”  
21,34 mm [0.840 in]  
13,46 mm [0.530 in]  
9,96 mm [0.392 in]  
10,34 mm [0.407 in]  
13,72 mm [0.540 in]  
10,29 mm [0.405 in]  
11,1 mm [0.437 in]  
8,28 mm [0.326 in]  
16,74 mm [0.659 in]  
9,25 mm [0.364 in]  
12,24 mm [0.482 in]  
10,85 mm [0.427 in]  
Height “H”  
R 1/2 BSPT  
R 1/4 BSPT  
R 1/8 BSPT  
1/8-27 PTF  
1/4-18 NPT  
1/8-27 NPT  
G 1/4 BSPP  
G 1/8 BSPP  
3/4-16 UNF  
7/16-20 UNF  
9/16-18 UNF  
1/2-20 UNF  
17,09 mm [0.673 in]  
13,74 mm [0.541 in]  
10,24 mm [0.403 in]  
9,24 mm [0.364 in]  
17,63 mm [0.694 in]  
12,497 mm [0.492 in]  
11,20 mm [0.441 in]  
7,59 mm [0.299 in]  
11,1 mm [0.437 in]  
9,09 mm [0.358 in]  
10,00 mm[0.394 in]  
9,09 mm [0.358 in]  
Figure 10. Wire out  
(bottom view)  
50,29 mm max.  
[1.98 in] max.  
Figure 11. Blade terminal  
Height  
“A”  
Diameter Diameter  
Port  
Height “H”  
“ØC”  
“ØD”  
38,35 mm max.  
[1.51 in] max.  
2,49 mm  
[0.098 in]  
18,8 mm  
[0.74 in]  
11,71 mm 10,998 mm  
(bottom view)  
M14 × 1.5  
M12 × 1.5  
M10 × 1.0  
[0.461 in]  
[0.433 in]  
Figure 12. Screw terminal  
2,49 mm  
[0.098 in]  
16,79 mm  
[0.661 in]  
9,70 mm  
[0.382 in]  
10,998 mm  
[0.433 in]  
1,6 mm  
[0.063 in]  
13,79 mm  
[0.543 in]  
8,41 mm  
[0.331 in]  
8,51 mm  
[0.335 in]  
38,35 mm max.  
[1.51 in] max.  
(bottom view)  
Safety and Productivity Solutions  
7
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ MEDIUM PRESSURE: ME SERIES  
Figure 20. ME Series Pressure Port Dimensions  
Figure 14. AMP Superseal 1.5  
H
H
65,3 mm max.  
[2.57 in] max.  
ØD  
(bottom view)  
Female connector part number (included): C-282105  
ØD  
Male mating connector (customer provided): C-282087  
IP rating: IP67  
Figure 15. Deutsch 3-pin  
A
H
ØD  
64 mm max.  
ØC  
[2.52 in] max.  
(bottom view)  
Female connector part number (included): DT04-3P  
Male mating connector (customer provided): DT06-3S  
IP rating: IP67  
Table 5. ME Series Pressure Port Diameters and Heights  
Port  
Diameter “ØD”  
21,34 mm [0.840 in]  
13,46 mm [0.530 in]  
9,96 mm [0.392 in]  
10,34 mm [0.407 in]  
13,72 mm [0.540 in]  
10,29 mm [0.405 in]  
11,1 mm [0.437 in]  
8,28 mm [0.326 in]  
16,74 mm [0.659 in]  
9,25 mm [0.364 in]  
12,24 mm [0.482 in]  
10,85 mm [0.427 in]  
Height “H”  
Figure 16. Deutsch 2-pin  
R 1/2 BSPT  
R 1/4 BSPT  
R 1/8 BSPT  
1/8-27 PTF  
1/4-18 NPT  
1/8-27 NPT  
G 1/4 BSPP  
G 1/8 BSPP  
3/4-16 UNF  
7/16-20 UNF  
9/16-18 UNF  
1/2-20 UNF  
17,09 mm [0.673 in]  
13,74 mm [0.541 in]  
10,24 mm [0.403 in]  
9,24 mm [0.364 in]  
17,63 mm [0.694 in]  
12,497 mm [0.492 in]  
11,20 mm [0.441 in]  
7,59 mm [0.299 in]  
11,1 mm [0.437 in]  
9,09 mm [0.358 in]  
10,00 mm[0.394 in]  
9,09 mm [0.358 in]  
65,5 mm max.  
[2.58 in] max.  
(bottom view)  
Female connector part number (included): DT04-2P  
Male mating connector (customer provided): DT06-2S  
IP rating: IP67  
Figure 17. Wire out  
48,51 mm max.  
[1.91 in] max.  
(bottom view)  
Height  
Diameter Diameter  
IP rating: IP67  
Port  
Height “H”  
“A”  
“ØC”  
“ØD”  
Figure 18. Blade terminal  
2,49 mm  
[0.098 in]  
18,8 mm  
[0.74 in]  
11,71 mm 10,998 mm  
[0.461 in]  
M14 × 1.5  
M12 × 1.5  
M10 × 1.0  
[0.433 in]  
2,49 mm  
[0.098 in]  
16,79 mm  
[0.661 in]  
9,70 mm  
[0.382 in]  
10,998 mm  
[0.433 in]  
1,6 mm  
[0.063 in]  
13,79 mm  
[0.543 in]  
8,41 mm  
[0.331 in]  
8,51 mm  
[0.335 in]  
38,9 mm max.  
[1.57 in] max.  
(bottom view)  
Figure 19. Screw terminal  
38,9 mm max.  
[1.57 in] max.  
(bottom view)  
8
sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ LOW PRESSURE: LP SERIES, LE SERIES  
Figure 21. AMP Superseal 1.5  
Figure 27. LP/LE Series Pressure Port Dimensions  
H
H
58,93 mm max.  
[2.32 in] max.  
ØD  
(bottom view)  
ØD  
Figure 22. Deutsch 3-pin  
A
H
ØD  
ØC  
57,66 mm max.  
[2.27 in] max.  
(bottom view)  
Table 6. LP/LE Series Pressure Port Diameters and Heights  
Figure 23. Deutsch 2-pin  
Port  
Diameter “ØD”  
21,34 mm [0.840 in]  
13,46 mm [0.530 in]  
9,96 mm [0.392 in]  
10,34 mm [0.407 in]  
13,72 mm [0.540 in]  
10,29 mm [0.405 in]  
11,1 mm [0.437 in]  
8,28 mm [0.326 in]  
16,74 mm [0.659 in]  
9,25 mm [0.364 in]  
12,24 mm [0.482 in]  
10,85 mm [0.427 in]  
Height “H”  
R 1/2 BSPT  
R 1/4 BSPT  
R 1/8 BSPT  
1/8-27 PTF  
1/4-18 NPT  
1/8-27 NPT  
G 1/4 BSPP  
G 1/8 BSPP  
3/4-16 UNF  
7/16-20 UNF  
9/16-18 UNF  
1/2-20 UNF  
17,09 mm [0.673 in]  
13,74 mm [0.541 in]  
10,24 mm [0.403 in]  
9,24 mm [0.364 in]  
17,63 mm [0.694 in]  
12,497 mm [0.492 in]  
11,20 mm [0.441 in]  
7,59 mm [0.299 in]  
11,1 mm [0.437 in]  
9,09 mm [0.358 in]  
10,00 mm [0.394 in]  
9,09 mm [0.358 in]  
58,93 mm max.  
[2.32 in] max.  
(bottom view)  
Figure 24. Wire out  
42,16 mm max.  
[1.66 in] max.  
(bottom view)  
IP rating: IP67  
Height  
“A”  
Diameter Diameter  
Port  
Height “H”  
Figure 25. Spade terminal  
“ØC”  
“ØD”  
2,49 mm  
[0.098 in]  
18,8 mm  
[0.74 in]  
11,71 mm 10,998 mm  
M14 × 1.5  
M12 × 1.5  
M10 × 1.0  
[0.461 in]  
[0.433 in]  
2,49 mm  
[0.098 in]  
16,79 mm  
[0.661 in]  
9,70 mm  
[0.382 in]  
10,998 mm  
[0.433 in]  
1,6 mm  
[0.063 in]  
13,79 mm  
[0.543 in]  
8,41 mm  
[0.331 in]  
8,51 mm  
[0.335 in]  
33,02 mm max.  
[1.30 in] max.  
(bottom view)  
Figure 26. Screw terminal  
(bottom view)  
33,02 mm max.  
[1.30 in] max.  
Safety and Productivity Solutions  
9
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
DIMENSIONS ꢀ 1000 SERIES, 5000 SERIES  
Figure 28. 1000 Series Dimensions  
11,18 mm [0.44 in] min.  
last full thread ref.  
12,4 mm  
[0.488 in]  
6,02 mm  
[0.237 in]  
33,1 mm  
[1.303 in]  
31,5 mm  
[1.24 in]  
65,6 mm  
[2.583 in]  
55,11 mm  
[2.17 in]  
34,85 mm  
[1.37 in]  
5,5 mm  
[0.22 in]  
M 10 x 1.25 ꢀ6G  
45°  
45°  
2X 9,91 mm  
[0.39 in]  
3,2 mm  
[0.13 in]  
8,99 mm  
[0.35 in]  
1,5 x 45°  
Ø2,5 cross drill  
0.25 x 45° chamfer  
2,1 mm  
[0.08 in]  
Figure 29. 5000 Series Dimensions  
8ꢀ32 x 1/4 screw (3)  
1/8ꢀ27 NPT  
0.500 hex ref.  
Ø 37,34 mm  
[Ø 1.47 in]  
ref.  
58,42 mm  
[2.3 in] ref.  
10 sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
NOMENCLATURE: HIGH PRESSURE  
For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, nonꢁadjustable set point, 550 psi set  
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, coldꢁrolled steel base, glycolꢁbased  
fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units.  
P
N
S
HP  
R
P
F
A
01  
AA  
05500  
Pressure  
Set Point  
Actuation/  
Application  
Connector  
Type  
Pressure  
Unit  
Packaging  
Options  
Port Type  
Output  
Base  
Series  
Set Point  
Options  
Petroleum-based  
hydraulic fluid  
(Nitrile)  
HP Series  
HE Series  
(100 psi to  
4500 psi),  
High  
Rising  
Cold-rolled  
steel  
Standard  
switch  
1/4 in Spade  
Terminals*  
Individually  
boxed units*  
6,89 bar to 310,26 bar  
[100 psi to 4500 psi]  
psig,  
sealed gage  
SPST-NO,  
silver contacts  
1/4-18 NPT  
factory set,  
non-adjustable  
S
01  
02  
R
F
A
B
C
N
P
A
B
C
P
B
N
C
AA  
BA  
CA  
DA  
EA  
FA  
Falling  
factory set,  
non-adjustable  
NOTE:  
Pressure set point  
is always five digits.  
bar,  
sealed gage  
Screw  
Terminals*  
With 3 shrink  
sleeve  
Individually  
boxed units**  
Glycol-based  
fluid (EPDM)  
SPST-NC,  
silver contacts  
1/8-27 NPT  
1/2-20 UNF  
With shrink  
sleeve  
(plastic coating)  
NOTE:  
25 individual  
EDPM O-ring option only available  
from 100 psi to 250 psi.  
SPDT-NO/NC,  
silver contacts  
Deutsch DT04-3P-E005  
(3-Pin Connector)*  
boxes packed in  
Set point below 100 psi  
is available only with  
HP Series (Body Style B).  
15 bulk packaging*  
D
For bar, the set point  
value will be multiplied  
by 100 and entered  
in the listing. For example,  
15,45 Bar is noted as 01545.  
This allows for 2 decimal  
places.  
Pressure  
Switch  
With shrink  
sleeve  
(acrylic coating)  
25 individual  
Amp Super Seal 1.5 -  
282105-1  
(3-Pin Connector)*  
NO, gold  
inlay contacts  
boxes packed in  
M12 x 1.5  
M14 x 1.5  
D
F
H
16 bulk packaging**  
E
F
50 individual  
304,8 mm [12 in]  
total wire length  
10-inch Cable, 18 AWG  
(Wire Out, No Connector)  
NC, gold  
inlay contacts  
boxes packed in  
20 bulk packaging*  
J
K
E
F
50 individual  
10-inch Cable w/Deutsch  
DT04-3P-E005  
(3-Pin Connector) (16 AWG)*  
SPDT(NO/NC),  
gold inlay  
contacts  
With conduit  
sleeve  
For psi, the set point  
value will be multiplied  
by 10 and entered  
in the listing. For example,  
245.5 psi is noted as 02455.  
This allows for 1 decimal place.  
boxes packed in  
9/16-18 UNF  
21 bulk packaging**  
G
H
G
H
K
10-inch Cable w/Amp  
Super Seal 1.5 - 282105-1  
(3-Pin Connector) (18 AWG)*  
NO, with 510 /  
0.5 W & 160 /  
0.5 W resistors  
With Vibra seal for  
port threads  
25 units in  
bulk packaging*  
3/4-16 UNF  
M18 x 1.5  
25  
GA  
HA  
JA  
#8-32 screw with  
external tooth  
lockwasher***  
10-inch Cable w/Metripack  
280 Delphi 15300002  
(2-Pin Connector) (18 AWG)  
25 units in  
bulk packaging**  
NC, with 3000 /  
0.125 W resistor  
J
26  
50 individual  
10-inch Cable w/  
914,4 mm [36 in]  
total wire length  
parts in  
7/16-20 UNF  
Din43650-C  
K
50 bulk packaging*  
M
N
T
(3-Pin Connector) (18 AWG)*  
304,8 mm [12 in]  
total wire length with  
acrylic sleeve  
10-inch Cable w/M12x1  
(Brad Harrison Micro) -  
21032121306 Harting P/N  
(3-Pin Connector) (18 AWG)*  
* Not applicable for HP  
Series (Base Style B)  
7/8-14 UNF  
M10 x 1.0  
L
KA  
** Not applicable for  
HP (Base Style A) & HE Series  
914,4 mm [36 in]  
total wire length with  
acrylic sleeve  
M
10-inch Cable w/Packard  
Weatherpack Male Terminal -  
12020827 (3-Pin Connector)  
(18 AWG)*  
LA  
MA  
NA  
*** For screw terminal option  
only  
10-inch Cable w/Deutsch  
DT04-2P-E005  
(2-Pin Connector) (18 AWG)  
HP Series Port Types  
Thread Type  
Base Style A  
n/a  
Base Style B  
100 psi to 4500 psi  
100 psi to 4500 psi  
n/a  
3-inch Cable w/Packard 2P  
Tower Connector -  
12015792 (2-Pin Connector)  
(18 AWG)  
A = 1/4-18 NPT  
B = 1/8-27 NPT  
C = 1/2-20 UNF  
E = M12 x 1.5  
F = M14 x 1.5  
n/a  
2.75-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(18 AWG)  
PA  
RA  
SA  
>975 psi  
n/a  
4-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(16 AWG)  
100 psi to 4500 psi  
n/a  
>350 psi  
5.5-inch Cable w/ITT  
Cannon 2P Sure-Seal  
Circular Connector -  
SS2R-120-1804-000 (2-Pin  
Connector) (18 AWG)  
G = 9/16-18 UNF >350 psi  
<350 psi  
H = 3/4-16 UNF  
K = M18 x 1.5  
>150 psi  
<150 psi  
150 psi to 4500 psi n/a  
8.5-inch Cable w/ITT  
Cannon 3P Sure-Seal  
Circular Connector -  
SS3R-120-8551-001 (3-Pin  
Connector) (16 AWG)*  
TA  
M = 7/16-20 UNF n/a  
100 psi to 4500 psi  
100 psi to 4500 psi  
N = 7/8-14 UNF  
T = M10 x 1.0  
150 psi to 4500 psi n/a  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT06-3S-EP06 (3-Socket  
Connector) (16 AWG)*  
n/a  
UA  
VA  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT04-3P-E005 (3-Pin  
Connector) (16 AWG)*  
Port Type A, B, E, M, and T will be available only with HP Series.  
Base Style B will be available only with HP Series  
4.5-inch Cable w/ 1/4 in  
Spade Terminals 6,3 mm x  
0,8 mm (16 AWG)  
WA  
XA  
YA  
ZA  
BB  
CB  
DB  
EB  
FB  
GB  
10-inch Cable w/ Metripack  
2-Pin Shroud Connector  
153000027 (18 AWG)  
6-inch Cable w/Amp  
Super Seal 1.5 - 282104-1  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/Deutsch  
DT06-2S-CE06 (2-Socket  
Connector) (18 AWG)  
10-inch Cable w/Metripack  
150 Delphi 12129615  
(3-Pin Connector) (18 AWG)  
6-inch Cable w/ AMP Super  
Seal 1.5 - 282080-1  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/AMP 2,5 mm  
System Series Connector  
1-967402-1 (18 AWG)*  
4.5-inch Cable w/Packard  
Shroud Connector 12015792  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/Metripack  
150 Delphi 12052641  
(2-Pin Connector) (18 AWG)  
8.5-inch Cable w/Deutsch  
Plug HD 16-3 96S  
(3-Pin Connector) (16 AWG)*  
*These connectors are designed for dual circuit (SPDT) by default.  
They can be used for single-circuit applications (SPNC/SPNO) by  
making suitable connections. Refer to wiring diagram.  
Safety and Productivity Solutions 11  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
NOMENCLATURE: MEDIUM PRESSURE, HIGH BURST  
For example, MHR01500PFPVMAAA01 defines a medium pressure, high burst switch, rising factory set, non-adjustable set  
point, 150 psi set point, psig, sealed gage pressure unit, 1/418 NPT port type, SPSTNO contacts output, stainless steel base,  
LTNB diaphragm, and spade terminal connectors.  
M
P
N
AA  
MH  
R
P
A
A
01  
01500  
Connector  
Type  
Pressure  
Set Point  
Actuation/  
Application  
Pressure  
Unit  
Packaging  
Options  
Port Type  
Output  
SPST-NO  
Base  
Series  
Set Point  
Options  
MH Series  
Medium  
Pressure  
Switch  
Rising  
factory set,  
non-adjustable  
Standard  
switch  
Cold-rolled  
steel  
1/4 in Spade  
Terminals  
LTNB diaphragm  
Individually  
01  
boxed units  
0,24 bar to 10,34 bar  
[3.5 psi to 150 psi]  
psig,  
sealed gage  
1/4-18 NPT  
N
B
V
AA  
BA  
DA  
EA  
HA  
MA  
A
C
R
F
A
B
C
M
N
E
P
B
P
(Low-temp Buna N)  
With shrink  
sleeve  
(plastic coating)  
25 individual  
Falling  
factory set,  
non-adjustable  
HNBR diaphragm  
(Hydrogenated Nitrile  
Butadiene Rubber)  
NOTE:  
Screw  
Terminals  
bar,  
sealed gage  
boxes packed in  
SPST-NC  
Brass  
1/8-27 NPT  
M
15 bulk packaging  
Pressure set point  
is always five digits.  
With shrink  
sleeve  
(acrylic coating)  
Amp Super Seal 1.5 -  
282105-1  
(3-Pin Connector)  
EPDM diaphragm  
(Ethylene-Propylene-  
Diene Monomer)  
bar,  
true gage*  
150 units in  
bulk packaging  
Rising,  
field adjustable*  
Stainless  
steel  
1/2-20 UNF  
T
For bar, the set point  
value will be multiplied  
by 100 and entered  
in the listing. For example,  
15,45 Bar is noted as  
01545. This allows for  
2 decimal places.  
20  
25  
M
T
D
F
25 units in  
bulk packaging  
Falling,  
field adjustable*  
10-inch Cable, 18 AWG  
(Wire Out, No Connector)  
psig,  
true gage*  
304,8 mm [12 in]  
total wire length  
C
1/8-27 PTF  
D
* Field adjustable option is only  
available for:  
1. Blade and screw terminations  
(SPDT, SPNO, SPNC)  
2. Deutsch DT04-3P  
(SPDT, SPNO, SPNC)  
150 individual  
10-inch Cable w/Metripack  
280 Delphi 15300002  
(2-Pin Connector) (18 AWG)*  
psig,  
With conduit  
sleeve  
boxes packed in  
sealed gage  
with epoxy**  
30 bulk packaging  
G
M12 x 1.5  
M14 x 1.5  
G
H
E
F
G
H
J
L
For psi, the set point  
value will be multiplied  
by 10 and entered  
in the listing. For example,  
245.5 psi is noted as 02455.  
This allows for 1 decimal place.  
10-inch Cable w/Deutsch  
DT04-2P-E005  
(2-Pin Connector) (18 AWG)  
bar,  
sealed gage  
with epoxy**  
With Vibra seal  
for threads  
H
J
3. Amp Superseal 1.5 (3-pin)  
(SPNO & SPNC)  
3-inch Cable w/Packard 2P  
Tower Connector -  
12015792 (2-Pin Connector)  
(18 AWG)  
#8-32 screw with  
external tooth  
lockwasher***  
*Blade and screw electrical  
terminations are available  
with only the the true gage  
option.  
9/16-18 UNF  
3/4-16 UNF  
G1/8 BSPP  
NA  
PA  
RA  
SA  
WA  
914,4 mm [36 in]  
total wire length  
2.75-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(18 AWG)  
K
L
**Connector cavity and roll  
forming area filled with epoxy  
to meet dunk test sealing  
capability.  
304,8 mm [12 in]  
total wire length  
w/ shrink sleeve  
4-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(16 AWG)  
914,4 mm [36 in]  
total wire length  
w/ shrink sleeve  
M
3/8-24 UNF  
5.5-inch Cable w/ITT  
Cannon 2P Sure-Seal  
Circular Connector -  
SS2R-120-1804-000 (2-Pin  
Connector) (18 AWG)  
***applicable only for  
screw terminal version.  
7/16-20 UNF  
M
P
R
T
V
4.5-inch Cable w/ 1/4 in  
Spade Terminals 6,3 mm x  
0,8 mm (16 AWG)*  
1/2-14 NPT  
R1/8 BSPT  
M10 × 1.0  
10-inch Cable w/ Metripack  
2-Pin Shroud Connector  
153000287 (18 AWG)  
XA  
YA  
ZA  
AB  
CB  
DB  
EB  
FB  
6-inch Cable w/Amp  
Super Seal 1.5 - 282104-1  
(2-Pin Connector) (18 AWG)*  
10-inch Cable w/Deutsch  
DT06-2S-CE06 (2-Socket  
Connector) (18 AWG)  
R1/2 BSPT  
Deutsch DT04-2P-E005  
(2-Pin Connector)  
G1/4 BSPP  
R1/4 BSPT  
Y
Z
6-inch Cable with Amp  
Super Seal 1.5 - 282080-1  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/AMP 2,5 mm  
System Series Connector  
1-967402-1 (18 AWG)*  
4.5-inch Cable w/Packard  
Shroud Connector 12015792  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/Metripack  
150 Delphi 12052641  
(2-Pin Connector) (18 AWG)  
*These connectors are designed for dual circuit (SPDT) by default.  
They can be used for single-circuit applications (SPNC/SPNO) by  
making suitable connections. Refer to wiring diagram.  
12 sensing.honeywell.com  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
NOMENCLATURE: MEDIUM PRESSURE  
For example, MER01500PFPVKAAA01 defines a medium pressure switch, rising factory set, non-adjustable set point, 55 psi set  
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO gold-plated contacts output, stainless steel base, Kapton®  
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed  
units.  
K
P
V
AA  
ME  
R
P
F
A
01  
01500  
Connector  
Type  
Pressure  
Set Point  
Actuation/  
Application  
Pressure  
Unit  
Packaging  
Options  
Port Type  
Output  
Base  
Series  
Set Point  
Options  
Kapton® diaphragm  
(Teflon® coated),  
Nitrile O-ring1  
Kapton® diaphragm  
(Teflon® coated),  
EPDM O-ring2  
1 Air, Petroleum-based  
hydraulic fluid, engine oil  
2 Glycol-based fluid  
ME Series  
Medium  
Pressure  
Switch  
Rising  
Cold-rolled  
steel with  
Standard  
switch  
1/4 in Spade  
Terminals  
Individually  
01  
boxed units  
1,72 bar to 24,13 bar  
[25 psi to 350 psi]  
psig,  
sealed gage  
SPST-NO,  
gold-plated contacts  
factory set,  
non-adjustable  
1/4-18 NPT  
N
V
AA  
BA  
CA  
DA  
EA  
FA  
A
B
C
R
F
A
B
C
K
H
P
B
P
M
Y
E
F
zinc plating  
25 individual  
Falling  
factory set,  
non-adjustable  
NOTE:  
Pressure set point  
is always five digits.  
Screw  
Terminals  
With 3 shrink  
sleeve  
bar,  
sealed gage  
SPST-NC,  
gold-plated contacts  
Stainless  
steel  
boxes packed in  
1/8-27 NPT  
15 bulk packaging  
With shrink  
sleeve  
(plastic coating)  
Deutsch DT04-3P-E005  
(3-Pin Connector)  
SPDT-NO/NC,  
gold-plated contacts  
150 units in  
bulk packaging  
bar,  
true gage  
Rising,  
field adjustable*  
1/2-20 UNF  
T
For bar, the set point  
value will be multiplied  
by 100 and entered  
in the listing. For example,  
15,45 Bar is noted as  
01545. This allows for  
2 decimal places.  
20  
M
T
With shrink  
sleeve  
(acrylic coating)  
Amp Super Seal 1.5 -  
282105-1  
(3-Pin Connector)  
Falling,  
field adjustable*  
NO, with 510 /  
0.5 W & 160 /  
0.5 W resistors  
25 2bu5lkunpiatsckinaging  
psig,  
true gage  
C
D
E
F
1/8-27 PTF  
D
* Field adjustable option is only  
available for:  
1. Blade and screw terminations  
(SPDT, SPNO, SPNC)  
2. Deutsch DT04-3P  
(SPDT, SPNO, SPNC)  
psig,  
sealed gage  
with epoxy  
150 individual  
10-inch Cable, 18 AWG  
(Wire Out, No Connector)  
With 1/8 W resistor  
between terminals  
NC, with 3000 /  
0.125 W resistor  
boxes packed in  
30 bulk packaging  
M12 x 1.5  
M14 x 1.5  
G
H
E
F
For psi, the set point  
value will be multiplied  
by 10 and entered  
in the listing. For example,  
245.5 psi is noted as 02455.  
This allows for 1 decimal place.  
10-inch Cable w/Deutsch  
DT04-3P-E005  
(3-Pin Connector) (16 AWG)*  
bar,  
sealed gage  
with epoxy  
304,8 mm [12 in]  
total wire length  
3. Amp Superseal 1.5 (3-pin)  
(SPNO & SPNC)  
10-inch Cable w/Amp  
Super Seal 1.5 - 282105-1  
(3-Pin Connector) (18 AWG)*  
Blade and screw electrical  
terminations are available  
with only the the true gage  
option.  
With conduit  
sleeve  
GA  
HA  
JA  
9/16-18 UNF  
G
H
G
H
J
10-inch Cable w/Metripack  
280 Delphi 15300002  
(2-Pin Connector) (18 AWG)*  
With Vibra seal  
for port threads  
3/4-16 UNF  
10-inch Cable w/  
#8-32 screw with  
external tooth  
lockwasher  
Din43650-C  
G1/8 BSPP  
J
(3-Pin Connector) (18 AWG)*  
10-inch Cable w/M12x1  
(Brad Harrison Micro) -  
21032121306 Harting P/N  
(3-Pin Connector) (18 AWG)*  
914,4 mm [36 in]  
total wire length  
7/16-20 UNF  
K
M
R
KA  
With port neck  
O-ring for LPS  
10-inch Cable w/Packard  
Weatherpack Male Terminal -  
12020827 (3-Pin Connector)  
(18 AWG)*  
R1/8 BSPT  
R
LA  
MA  
NA  
*** For screw terminal option  
only  
T
V
Y
Z
M10 × 1.0  
R1/2 BSPT  
G1/4 BSPP  
10-inch Cable w/Deutsch  
DT04-2P-E005  
(2-Pin Connector) (18 AWG)  
3-inch Cable w/Packard 2P  
Tower Connector -  
12015792 (2-Pin Connector)  
(18 AWG)  
2.75-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(18 AWG)  
PA  
RA  
SA  
R1/4 BSPT  
4-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(16 AWG)  
5.5-inch Cable w/ITT  
Cannon 2P Sure-Seal  
Circular Connector -  
SS2R-120-1804-000 (2-Pin  
Connector) (18 AWG)  
8.5-inch Cable w/ITT  
Cannon 3P Sure-Seal  
Circular Connector -  
SS3R-120-8551-001 (3-Pin  
Connector) (16 AWG)*  
TA  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT06-3S-EP06 (3-Socket  
Connector) (16 AWG)*  
UA  
VA  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT04-3P-E005 (3-Pin  
Connector) (16 AWG)*  
4.5-inch Cable w/ 1/4 in  
Spade Terminals 6,3 mm x  
0,8 mm (16 AWG)*  
WA  
10-inch Cable w/ Metripack  
2-Pin Shroud Connector  
153000287 (18 AWG)  
XA  
6-inch Cable w/Amp  
Super Seal 1.5 - 282104-1  
(2-Pin Connector) (18 AWG)*  
YA  
ZA  
AB  
BB  
CB  
DB  
EB  
FB  
GB  
10-inch Cable w/Deutsch  
DT06-2S-CE06 (2-Socket  
Connector) (18 AWG)  
Deutsch DT04-2P-E005  
(2-Pin Connector)  
10-inch Cable w/Metripack  
150 Delphi 12129615  
(3-Pin Connector) (18 AWG)*  
6-inch Cable with Amp  
Super Seal 1.5 - 282080-1  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/AMP 2,5 mm  
System Series Connector  
1-967402-1 (18 AWG)*  
4.5-inch Cable w/Packard  
Shroud Connector 12015792  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/Metripack  
150 Delphi 12052641  
(2-Pin Connector) (18 AWG)  
8.5-inch Cable w/Deutsch  
Plug HD 16-3 96S  
(3-Pin Connector) (16 AWG)  
*These connectors are designed for dual circuit (SPDT) by default.  
They can be used for single-circuit applications (SPNC/SPNO) by  
making suitable connections. Refer to wiring diagram.  
Safety and Productivity Solutions 13  
Honeywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series  
NOMENCLATURE: LOW PRESSURE  
For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set  
point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPSTNO gold-plated contacts output, stainless steel base, Kapton®  
diaphragm (Teflon® coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed  
units.  
K
P
V
AA  
LP  
R
P
F
A
01  
00550  
Connector  
Type  
Pressure  
Set Point  
Actuation/  
Application  
Pressure  
Unit  
Packaging  
Options  
Port Type  
Output  
Base  
Series  
Set Point  
Options  
Rising  
Kapton® diaphragm  
(Teflon® coated),  
Nitrile O-ring1  
Kapton® diaphragm  
(Teflon® coated),  
EPDM O-ring2  
LP Series,  
LE Series  
Low  
Pressure  
Switch  
Standard  
switch  
1/4 in Spade  
Terminals  
Individually  
01  
boxed units  
0,24 bar to 10,34 bar  
[3.5 psi to 150 psi]  
psig,  
sealed gage  
SPST-NO,  
gold-plated contacts  
Brass  
factory set,  
non-adjustable  
1/4-18 NPT  
B
N
V
AA  
BA  
CA  
DA  
EA  
FA  
A
B
C
R
F
A
B
C
K
H
T
P
B
P
M
Y
E
F
Cold-rolled  
steel with  
zinc plating  
25 individual  
Falling  
factory set,  
non-adjustable  
NOTE:  
Pressure set point  
is always five digits.  
Screw  
Terminals  
With 3 shrink  
sleeve  
bar,  
sealed gage  
SPST-NC,  
gold-plated contacts  
boxes packed in  
1/8-27 NPT  
15 bulk packaging  
With shrink  
sleeve  
(plastic coating)  
Tefzel® and Kapton®  
diaphragm,  
Deutsch DT04-3P-E005  
(3-Pin Connector)  
SPDT-NO/NC,  
gold-plated contacts  
Stainless  
steel  
150 units in  
bulk packaging  
bar,  
true gage  
Rising,  
field adjustable*  
1/2-20 UNF  
T
For bar, the set point  
value will be multiplied  
by 100 and entered  
in the listing. For example,  
15,45 Bar is noted as  
01545. This allows for  
2 decimal places.  
20  
M
T
Nitrile O-ring3  
Tefzel® and Kapton®  
diaphragm,  
With shrink  
sleeve  
(acrylic coating)  
Amp Super Seal 1.5 -  
282105-1  
(3-Pin Connector)**  
25 2bu5lkunpiatsckinaging  
Falling,  
field adjustable*  
NO, with 510 /  
1 W & 160 /  
psig,  
true gage  
C
D
F
1/8-27 PTF  
U
D
EPDM O-ring4  
1 W resistors****  
* Field adjustable option is only  
available for:  
1. Blade and screw terminations  
(SPDT, SPNO, SPNC)  
2. Deutsch DT04-3P  
(SPDT, SPNO, SPNC)  
150 individual  
1 Air, Petroleum-based  
hydraulic fluid, engine oil  
2 Glycol-based fluid  
3 For high temperature  
fluid media (LE Series only)  
4 For high temperature  
fluid media, glycol-based  
fluid (LE Series only)  
psig,  
sealed gage  
with epoxy  
10-inch Cable, 18 AWG  
(Wire Out, No Connector)*  
304,8 mm [12 in]  
total wire length  
NC, with 3000 /  
0.125 W resistor  
boxes packed in  
30 bulk packaging  
M12 x 1.5  
M14 x 1.5  
G
H
E
F
For psi, the set point  
value will be multiplied  
by 10 and entered  
in the listing. For example,  
245.5 psi is noted as 02455.  
This allows for 1 decimal place.  
10-inch Cable w/Deutsch  
DT04-3P-E005  
(3-Pin Connector) (16 AWG)*  
bar,  
sealed gage  
with epoxy  
NC with 510 /  
With conduit  
sleeve  
0.5 W and 160 /  
0.5 W resistors****  
G
H
G
3. Amp Superseal 1.5 (3-pin)  
(SPNO & SPNC)  
10-inch Cable w/Amp  
Super Seal 1.5 - 282105-1  
(3-Pin Connector) (18 AWG)*  
**** Available only on LP Series  
With Vibra seal  
for port threads  
Blade and screw electrical  
terminations are available  
with only the the true gage  
option.  
GA  
HA  
JA  
9/16-18 UNF  
G
H
J
10-inch Cable w/Metripack  
280 Delphi 15300002  
(2-Pin Connector) (18 AWG)*  
914,4 mm [36 in]  
total wire length  
3/4-16 UNF  
K
L
True gage option is available  
only up to 20 psig set  
point for integral connectors  
and wire out electrical  
terminations.  
304,8 mm [12 in]  
total wire length with  
acrylic sleeve  
10-inch Cable w/  
Din43650-C  
G1/8 BSPP  
(3-Pin Connector) (18 AWG)*  
914,4 mm [36 in]  
total wire length with  
acrylic sleeve  
10-inch Cable w/M12x1  
(Brad Harrison Micro) -  
7/16-20 UNF  
M
M
R
KA  
21032121306 Harting P/N  
(3-Pin Connector) (18 AWG)*  
*** For screw terminal option  
only  
10-inch Cable w/Packard  
Weatherpack Male Terminal -  
12020827 (3-Pin Connector)  
(18 AWG)*  
R1/8 BSPT  
LA  
MA  
NA  
T
V
Y
Z
M10 × 1.0  
R1/2 BSPT  
G1/4 BSPP  
10-inch Cable w/Deutsch  
DT04-2P-E005  
(2-Pin Connector) (18 AWG)  
3-inch Cable w/Packard 2P  
Tower Connector -  
12015792 (2-Pin Connector)  
(18 AWG)  
2.75-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(18 AWG)  
PA  
RA  
SA  
R1/4 BSPT  
4-inch Cable w/Packard  
2P Shroud Connector -  
12010973 (2-Pin Connector)  
(16 AWG)  
5.5-inch Cable w/ITT  
Cannon 2P Sure-Seal  
Circular Connector -  
SS2R-120-1804-000 (2-Pin  
Connector) (18 AWG)  
8.5-inch Cable w/ITT  
Cannon 3P Sure-Seal  
Circular Connector -  
SS3R-120-8551-001 (3-Pin  
Connector) (16 AWG)*  
TA  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT06-3S-EP06 (3-Socket  
Connector) (16 AWG)*  
UA  
VA  
10-inch Cable - Vacuum  
Impregnated w/Deutsch  
DT04-3P-E005 (3-Pin  
Connector) (16 AWG)*  
4.5-inch Cable w/ 1/4 in  
Spade Terminals 6,3 mm x  
0,8 mm (16 AWG)*  
WA  
10-inch Cable w/ Metripack  
2-Pin Shroud Connector  
153000287 (18 AWG)  
XA  
6-inch Cable w/Amp  
Super Seal 1.5 - 282104-1  
(2-Pin Connector) (18 AWG)*  
YA  
ZA  
AB  
BB  
CB  
DB  
EB  
FB  
GB  
10-inch Cable w/Deutsch  
DT06-2S-CE06 (2-Socket  
Connector) (18 AWG)  
Deutsch DT04-2P-E005  
(2-Pin Connector)  
10-inch Cable w/Metripack  
150 Delphi 12129615  
(3-Pin Connector) (18 AWG)*  
6-inch Cable with Amp  
Super Seal 1.5 - 282080-1  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/AMP 2,5 mm  
System Series Connector  
1-967402-1 (18 AWG)*  
4.5-inch Cable w/Packard  
Shroud Connector 12015792  
(2-Pin Connector) (18 AWG)  
10-inch Cable w/Metripack  
150 Delphi 12052641  
(2-Pin Connector) (18 AWG)  
8.5-inch Cable w/Deutsch  
Plug HD 16-3 96S  
(3-Pin Connector) (16 AWG)  
*These connectors are designed for dual circuit (SPDT) by default.  
They can be used for single-circuit applications (SPNC/SPNO) by  
making suitable connections. Refer to wiring diagram.  
**For electrical termination with SPST option, only SPNO  
configuration is available. SPNC configuration cannot be provided.  
14 sensing.honeywell.com  
m WARNING  
ADDITIONAL MATERIALS  
PERSONAL INJURY  
The following associated literature is available at  
sensing.honeywell.com:  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
• Product range guide  
• Product line guide  
Failure to comply with these instructions could result in  
death or serious injury.  
• Technical note: Smart Diagnostic Technology  
• Product application-specific information  
– Application Note: Honeywell Pressure Switches  
– Sensors and switches in front loaders  
– Sensors and switches in mobile cranes  
– Sensors and switches in oil rig applications  
– Industrial product line card  
m WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship during the appli-  
cable warranty period. Honeywell’s standard product warranty  
applies unless agreed to otherwise by Honeywell in writing;  
please refer to your order acknowledgement or consult your  
local sales office for specific warranty details. If warranted  
goods are returned to Honeywell during the period of coverage,  
Honeywell will repair or replace, at its option, without charge  
those items that Honeywell, in its sole discretion, finds defec-  
tive. The foregoing is buyer’s sole remedy and is in lieu of all  
other warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
Find out more  
Honeywell serves its customers  
through a worldwide network  
of sales offices, representatives  
and distributors. For  
While Honeywell may provide application assistance personally,  
through our literature and the Honeywell web site, it is buyer’s  
sole responsibility to determine the suitability of the product in  
the application.  
application assistance, current  
specifications, pricing or name  
of the nearest Authorized  
Distributor, contact your local  
sales office. To learn more  
about Honeywell’s sensing and  
switching products,  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this writing.  
However, Honeywell assumes no responsibility for its use.  
call +1-815-235-6847 or  
1-800-537-6945,  
visit sensing.honeywell.com,  
or e-mail inquiries to  
info.sc@honeywell.com  
Honeywell Safety and Productivity Solutions  
9680 Old Bailes Road  
500940815ENꢁIL50 GLOꢂ  
October 2016  
© 2016 Honeywell International Inc. All rights reserved.  
® DuPont™, Teflon®, Tefzel®, and Kapton® are trademarks or registered trademarks of E.I. du Pont de Nemours and Company  
Fort Mill, SC 29707  
honeywell.com  

相关型号:

LPT00600TJMBKAAA01

Strain Guage Sensor,
HONEYWELL

LPT00A20-16PX(023)

MIL Series Connector
AMPHENOL

LPT00A20-16PX(072)

MIL Series Connector
AMPHENOL

LPT00A20-16PY(072)

MIL Series Connector
AMPHENOL

LPT00A20-16PZ(023)

MIL Series Connector
AMPHENOL

LPT00A20-16SX(023)

MIL Series Connector
AMPHENOL

LPT00A20-16SX(072)

MIL Series Connector
AMPHENOL

LPT00A20-16SY(023)

MIL Series Connector
AMPHENOL

LPT00A20-16SY(072)

MIL Series Connector
AMPHENOL

LPT00A20-16SZ(023)

MIL Series Connector
AMPHENOL

LPT00A20-41PW(027)

MIL SERIES CONNECTOR
AMPHENOL

LPT00A20-41PY(027)

MIL Series Connector
AMPHENOL