ML500BS1PG [HONEYWELL]
High value and outstanding performance No internal elastomeric seals; 高价值和出色的性能无内部弹性密封件型号: | ML500BS1PG |
厂家: | Honeywell |
描述: | High value and outstanding performance No internal elastomeric seals |
文件: | 总2页 (文件大小:205K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
APPLICATIONS
MODEL ML • OEM PRESSURE TRANSDUCER
•
DIESEL ENGINES
•
REFRIGERATION AND
HVAC SYSTEMS
•
HYDRAULIC FLUID
PRESSURES
•
ThemodelMLpressuretransducercombines
the latest in ASIC technology with our proven
stainlesssteeldesign.Thisdigitallycompensated
transducer offers an unparalleled value and
performance combination making it the ideal
pressure sensing solution for demanding
automotive and industrial applications. Fully
temperature compensated, calibrated, and
amplified, the ML is available in 100 to 5000
PSIS pressure ranges.
GENERAL
INDUSTRIAL
PRESSURE
•
The ML has three standard output options:
a 0.50 to 4.50 Vdc ratiometric output from
5Vdcexcitation, a1.0to6.0Vdcregulatedout-
put from 7-35 Vdc excitation, and a 4-20 mA
current from 9-35 Vdc excitation. The ML
transducer delivers ±0.25% full scale accuracy
(BFSL)overawidetemperaturerangeof-40°C
to105°Candutilizesaprovenindustrystandard
connectorforhighreliabilityanduserflexibility.
OFF ROAD
VEHICLES
ML
FEATURES
BENEFITS
• High value and outstanding performance
• No internal elastomeric seals
• Amplified outputs
• Excellent OEM value
• Eliminates O-Ring compatability issues
• Eliminates cost of external amplifiers
• Not damaged by reversed excitation
• Accurate high speed measurements
• Protected from harsh environments
• Reverse polarity protection
• Less than 500 microseconds response time
• Designed to meet IP65 standards*
• Exceeds CE Heavy Industrial EMC
* With appropriate mating connector, Packard #12065287.
HOW TO ORDER
ML 100 P S 1 P G
Model
Range
Output
C = 0.5-4.5 VDC
G = 4-20 mA
R5 = 1-6 VDC
15
25
50
100 01K 001 016 100
200 02K 004 025 160
300 03K 006 040 250
500 05K 010 060 350
Termination
P = Packard
Pressure Connection
PSI
BAR
1 = 1/8-27 NPT
2 = 1/4-18 NPT
Unit
P = PSI
B = BAR
Reference
G = Gage (only on < 100 PSI)
S = Sealed
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
ML SERIES
•
PRESSURE TRANSDUCER
TECHNICAL SPECIFICATIONS
RANGES
DIMENSIONS
xx.xx = inches
(xx.x) = mm
15, 25, 50 PSIG; 100, 200, 300, 500, 1000, 2000, 3000, 5000 PSIS
6, 10, 16, 25, 40, 60, 100,160, 250 BAR
PHYSICAL
1.58
[40] *
0.60
[15] **
Proof Pressure
< 500 psi
2 X rated range
≥ 500 psi
1.5 X rated range
0.73
[19]
0.85
[22]
Not Intended for
Customer use
Burst Pressure
< 500 psi
10 X rated range
≥ 500 psi (30K psi max)
10 X rated range
Material in Contact
with Media
300 series SS,
braze compound
c
1.06
[27]
Weight
2.0 oz (57 gm)
ENVIRONMENTAL
Shock
b
a
50 g’s peak (5 ms), 100 g’s peak (11 ms)
Figure 514.2-5, Curve AK, Table 514.2-V
Vibration
1-1/16 [27] HEX
1/8-27 NPT or 1/4-18 NPT
Random Vibration Test (Overall g rms = 20.7 minimum)
* Maximum
ELECTRICAL
Ratiometric Voltage Regulated
Current
** 0.75 [19] for 1/4-18 NPT
Zero Output
0.5 Vdc
1.0 Vdc
4.0 mA
Full Scale Output*
4.0 Vdc
5.0 Vdc
16 mA
(0.50-4.50 Vdc)
(1.0-6.0 Vdc)
(4-20 mA)
Excitation
5 Vdc ±250 mV
(7.0 V max)
7-35 Vdc
9.5-35 Vdc
N/A
PIN AND WIRE CODES
Supply Current
5 mA typical
(7 mA max)
5 mA typical
(7 mA max)
Pins
A
Voltage
+ Excitation
Output
Current
+ Excitation
- Excitation
NC
Source (nominal)
Sink (nominal)
2.0 mA
2.0 mA
N/A
N/A
B
20 µA
@ zero output
20 µA
@ zero output
C
Common
Supply Rejection Ratio 90 db
90 db
90 db
N/A
Output Impedance
PERFORMANCE
Response Time
25 W max.
25 W max.
< 500 microseconds
EMI/RFI Exceeds CE heavy industrial (30v/m radiated 150kHz-1gHz)
Electrical
Connection
Packard Metri-Pack™ connector requires
Packard #12065287 mating connector
Accuracy
±0.25% F.S.O. best fit straight line.
Includes: non-linearity, hysteresis, non-repeatability.
Thermal errors not included. 0.5% < 100 PSI **
Total Error Band
±2% Typical (±3% Max.) F.S.O.
Includes: zero offset error, span error, thermal effect on zero
and thermal effect on span, non-linearity, hysteresis, non-repeatability
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Compensated Operating and
Storage Temperature Range
-40° to 105°C
(-40° to 221°F)
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
* PSIG vented thru vent hole protected by Gortex® filter
NOTE: All specifications are measured at 25° C (77° F) and at rated excitation unless
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
otherwise specified.
NOTE: Meets IEC-68-2 or MIL-STD 810C.
NOTE: Contact the factory to discuss other pressure ranges.
Item # 1121700 M.G. 3/01 Rev. A
Sensing and Control
Honeywell
100 Discovery Way
Acton, MA 01720 USA
Tel: (877) 384-1300; Fax: (978) 263-0630
www.honeywell.com/sensing/