PX2AN2XX150PAAAX [HONEYWELL]

PX2 Series Heavy Duty Pressure Transducers, absolute, 0 psi to 150 psi, 4.75 V to 5.25 V input, ratiometric 5.0 Vdc 10 %Vs to 90 %Vs output, 1/8-27 NPT, Delphi Metri-Pack 150;
PX2AN2XX150PAAAX
型号: PX2AN2XX150PAAAX
厂家: Honeywell    Honeywell
描述:

PX2 Series Heavy Duty Pressure Transducers, absolute, 0 psi to 150 psi, 4.75 V to 5.25 V input, ratiometric 5.0 Vdc 10 %Vs to 90 %Vs output, 1/8-27 NPT, Delphi Metri-Pack 150

传感器 换能器
文件: 总10页 (文件大小:1970K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Heavy Duty Pressure Transducers  
50069942  
Datasheet  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Issue I  
Datasheet  
FEATURES  
• Pressure range: 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to  
1000 psi  
• Pressure reference: Absolute, sealed gage or vented gage  
• Pressure port types: 7/16-20 UNF 1/4 in 45° Flare Female  
Schrader (SAE J512), 7/16-20 UNF 45° Flare Male (SAE  
J513), 7/16-20 UNF 37° Flare Male (SAE J514), G1/4 (ISO  
1179-3), G1/8 (ISO 1179-3), M12 x 1.5 (ISO 6149-3),  
1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF, (SAE J1926-3), or  
7/16-20 UNF (SAE J1926-3)  
• Electrical connector types: Metri-Pack 150 (UL 94 HB or V-0  
options), Micro M12, DIN, Deutsch, or cable harness  
(1 m, 2 m, 3 m, or 5 m)  
DESCRIPTION  
• Total Error Band: 2.0 ꢀ  
Honeywell’s PX2 Series Heavy Duty Pressure Transducers  
are a portfolio of configurable pressure sensors that use  
piezoresistive sensing technology with ASIC (Application  
Specific Integrated Circuit) signal conditioning in a stainless  
steel housing. The PX2 Series is fully calibrated and  
compensated for offset, sensitivity, temperature effects and  
non-linearity using the on-board ASIC. These transducers  
measure absolute, sealed gage, or vented gage pressure. The  
absolute versions have an internal vacuum reference and  
an output value proportional to absolute pressure, sealed  
gage versions have an internal pressure reference of one  
atmosphere at sea level, and vented gage versions measure  
pressure with respect to ambient pressure. They are RoHS  
compliant and are designed and manufactured according to  
ISO 9001 standards.  
• Operating and compensated temperature range: -40°C to  
125°C [-40°F to 257°F]  
• Response time: <2 ms  
• Life: Minimum of 10 million cycles to operating pressure  
• Output transfer function: Ratiometric, regulated or current  
• Mechanical shock rating: 100 G per MIL-STD-202F, Method  
213B, Cond. F  
• Vibration rating: 20 G sweep, 10 Hz to 2000 Hz  
• Ingress protection: Up to IP69K  
• Radiated immunity protection: Up to 100 V/m (ISO 11452-2)  
• Flame retardant options: UL 94 HB standard on all electrical  
terminations; UL 94 V-0 available upon request  
POTENTIAL APPLICATIONS  
• Industrial: Refrigerant pressure monitoring in HVAC/R  
systems; air compressor system pressure  
• Transportation: Air system monitoring; hydraulic oil pressure  
monitoring  
VALUE TO CUSTOMERS  
• Media compatibility: Common HFC (hydrofluorocarbon)  
refrigerants such as R410A and R134A, next generation low  
global warming potential (GWP) refrigerants such as R448A  
(Solstice® N40), R32 and R1234ZE, engine oil, petroleum-  
based hydraulic fluids, DOT 3 brake fluid, and dry air. For  
ammonia and other corrosive media, see Honeywell’s SPT  
Series.  
The PX2 Series is not recommended for use with media  
involving water, saturated air such as steam and vapor, and  
ammonia.  
PORTFOLIO  
• Enhanced durability: The PX2 Series can operate in the  
rigorous environments commonly found in HVAC/R and air  
compressor applications. The sensor can survive at least 10  
million pressure cycles and has an ingress protection rating  
up to IP69K.  
Honeywell’s PX2 Series joins the PX3 Series, MLH Series, and  
SPT Series heavy duty pressure transducers.  
Sensing and Internet of Things  
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Table 1. Performance Specifications1  
Characteristic  
Parameter  
-40°C to 125°C [-40°F to 257°F]  
-40°C to 125°C [-40°F to 257°F]  
-40°C to 125°C [-40°F to 257°F]  
(See Table 3.)  
Operating temperature range2  
Storage temperature range3  
Compensated temperature range4  
Overpressure minimum rating5  
Burst pressure minimum rating6  
Long term stability  
Accuracy7  
(See Table 3.)  
0.5 ꢀFSS9 (1000 hr at 25°C [77°F])  
0.25 ꢀFSS9 (See Figure 1.)  
1 ꢀFSS9  
Offset error8  
Total Error Band10  
2 ꢀFSS9 (-40°C to 125°C [-40°F to 257°F]) (See Figure 1.)  
Response time11  
<2 ms  
Turn on time12  
<7 ms  
Life13  
minimum of 10 million cycles to operating pressure  
1
2
All specifications apply at 25°C and under operating conditions unless otherwise noted.  
Operating Temperature Range: The temperature range over which the product will produce an output proportional to pressure but may not remain  
within the specified performance limits.  
Storage Temperature Range: The temperature range over which the product may safely be exposed without excitation or pressure applied. Under  
these conditions the product will remain in specification after excursion to any temperatures within this range. Exposure to temperatures outside  
this range may cause permanent damage to the product.  
Compensated Temperature Range: The temperature range (or ranges) over which the product will produce an output proportional to pressure  
within the specified performance limits.  
3
4
5
Overpressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure  
is returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product.  
Burst Pressure: The maximum pressure that may be applied to the product without causing escape of the pressure media. The product should not  
be expected to function after exposure to any pressure beyond the rated burst pressure. This rating is also the case burst rating of the product.  
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C.  
Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.  
Offset Error: the maximum deviation in the output signal obtained when the reference pressure is applied at 25°C relative to the ideal transfer  
function.  
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the  
pressure range.  
6
7
8
9
10  
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes  
all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span,  
and thermal hysteresis.  
11  
Response Time: The response time of the transducer is the maximum amount of time that the transducer will take for the transducer to output a  
change from 10ꢀ to 90ꢀ of full scale in response to a 0ꢀ to 100ꢀ full scale step input pressure range.  
12 Turn On Time: Duration from power applied until first valid output.  
13  
Life may vary depending on the application in which transducer is used.  
Figure 1. Total Error Band (TEB) for the Total Error Band Series  
All Possible Errors  
Offset  
Full Scale Span  
Pressure Non-Linearity  
Pressure Hysteresis  
Pressure Non-Repeatability  
Thermal Effect on Offset  
Thermal Effect on Span  
Thermal Hysteresis  
Total  
Error  
Band  
Accuracy  
BFSL  
Sensing and Internet of Things  
2
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Table 2. Electrical Specifications  
Current  
Ratiometric Output  
Regulated Output  
Output  
Characteristic  
Output Transfer Function Order Code1  
AA  
AB  
AC  
AD  
CH  
BC  
BD  
BE  
BG  
Output transfer function1:  
null output value  
full scale output value  
10ꢀ of Vs 5ꢀ of Vs 10ꢀ of Vs 5ꢀ of Vs  
90ꢀ of Vs 95ꢀ of Vs 90ꢀ of Vs 95ꢀ of Vs  
4 mA  
4 mA  
1 V  
6 V  
0.25 V 0.5 V  
10.25 V 4.5 V  
1 V  
5 V  
full scale span (FSS)  
80ꢀ of Vs 90ꢀ of Vs 80ꢀ of Vs 90ꢀ of Vs 16 mA  
5 V  
9 V  
30 V3  
10 V  
13 V  
30 V3  
4 V  
8 V  
30 V3  
4 V  
8 V  
operating supply voltage, min.(Vs)2  
operating supply voltage, typ. (Vs)2  
operating supply voltage, max. (Vs)2  
4.75 V  
5 V  
4.5 V  
5 V  
3.135 V  
3.3 V  
3.135 V  
3.3 V  
8 V  
30 V4  
5.25 V  
5.5 V  
3.465 V  
3.465 V  
30 V3  
Supply current (typ.)  
5 mA  
4 mA  
5.5 mA  
Output load (pull up or down):  
minimum  
maximum  
2 kOhm  
2 kOhm  
(Vs - 8) x  
50 Ohm4  
Absolute voltage ratings5:  
minimum6  
-16 V  
16 V  
Vs  
-16 V  
30 V  
-16 V  
30 V  
12 V  
maximum6  
maximum applied to output pin  
(short circuit protection)7  
EMC rating8:  
CE compliance:  
electrostatic discharge  
radiated immunity  
fast transient burst  
immunity to conducted disturbances  
radiated emissions  
4 kV contact, 8 kV air per IEC 61000-4-2  
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3  
1 kV per IEC61000-4-4  
3 V per IEC61000-4-6  
40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 11  
ISO 11452-2 radiated immunity  
100 V/m 200 MHz to 2 GHz 20 V/m 200 MHz to 2 GHz  
1
2
3
4
5
Output transfer function options are shown in the Nomenclature and Order Guide. (See Figure 4.)  
Transducer will not produce valid output when supply voltage is outside of operating range.  
Applies at 25°C. See Figure 2 for Regulated Output Supply Voltage.  
Applies at 25°C. See Figure 3 for Current Output Supply Voltage.  
Absolute maximum ratings are the extreme limits the device can withstand without damage to the product. Voltages above these ratings may  
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability.  
Absolute voltage applies to potential across power and ground terminals.  
Short circuit protection between output pin and ground, and output pin and supply pin.  
All EMC ratings verified with the Metri-Pack 150 electrical connector type.  
6
7
8
Figure 2. Regulated Output Supply Voltage  
Figure 3. Current Output Supply Voltage  
Sensing and Internet of Things  
3
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Table 3. Pressure Ratings  
bar  
kPa  
MPa  
psi  
Operating Over-  
Burst Operating Over-  
Burst Operating Over-  
Burst Operating Over-  
Burst  
Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure  
1
1.6  
2
5
5
8
100  
160  
250  
400  
600  
500  
1000  
1000  
1700  
3100  
800  
1700  
1700  
2700  
5100  
1
1.6  
2.5  
4
3.1  
5.2  
6.9  
6.9  
6.9  
13.8  
13.8  
5.1  
8.6  
10.3  
10.3  
10.3  
20.6  
20.6  
15  
30  
70  
115  
250  
8
150  
10  
10  
17  
31  
31  
31  
52  
69  
69  
69  
69  
138  
138  
17  
50  
250  
400  
2.5  
4
17  
100  
150  
200  
250  
300  
500  
600  
667  
750  
800  
850  
1000  
450  
750  
27  
4.6  
6
450  
750  
6
51  
750  
1250  
1250  
1500  
1500  
1500  
1500  
2250  
2250  
3000  
3000  
8
51  
7
750  
10  
16  
25  
34  
40  
46  
60  
70  
51  
1000  
1000  
1000  
1000  
1500  
1500  
2000  
2000  
86  
103  
103  
103  
103  
206  
206  
Table 4. Pressure Reference Types  
Pressure Reference  
Description  
Output is proportional to the difference between applied pressure and a built-in fixed reference to  
vacuum (zero pressure), where the minimum operating pressure is set to absolute zero pressure  
(perfect vacuum).  
Absolute  
Output is proportional to the difference between applied pressure and a built-in fixed reference to  
1 atmA, where the minimum operating pressure is set to 14.7 psiA (1 atmA).  
Sealed gage1  
Sensor measures pressure relative to ambient pressure. Output is proportional to the difference  
between applied pressure and atmospheric (ambient) pressure, where the minimum operating  
pressure is set to atmospheric pressure.  
Vented gage2  
1
2
Sealed gage option only available in pressure ranges at or above 100 psi.  
Vented gage option only available in pressure ranges between 100 psi and 667 psi.  
Sensing and Internet of Things  
4
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Table 5. Environmental and Mechanical Characteristics  
Characteristic  
Mechanical shock  
Vibration  
Parameter  
100 G per MIL-STD-202F, Method 213B, Cond. F (at 25°C)  
20 G sweep, 10 Hz to 2000 Hz (at 25°C)  
Enclosure rating  
Wetted materials:  
port  
substrate  
adhesives  
per electrical connector type selection (See Figure 5.)  
304 stainless steel  
alumina ceramic  
epoxy  
electronics  
glass, silicon  
External materials:  
housing  
304 stainless steel  
connector:  
UL 94 HB (standard)  
UL 94 V-0 (optional)  
cable jacket  
PBT 30ꢀ GF, black  
PBT 30ꢀ GF, natural (beige)  
TPE  
Installation torque  
per pressure port type (See Figure 6.)  
CAUTION  
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES  
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating  
materials and thread sealants can result in significantly different torque values from one application to the next.)  
• When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.  
Ensure the sealant is rated for the application.  
• Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.  
• Always hand-start transducers into the hole to prevent cross threading and damage.  
• Ensure that torque is not applied to the electrical connector.  
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals  
can compromise ingress protection, leading to short circuits.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO PARTICULATES  
• Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All  
PX2 Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect sensor output.  
• It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less  
likely to enter and settle within the pressure transducer if it is in this position.  
• Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output;  
rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue.  
Failure to comply with these instructions may result in product damage.  
Sensing and Internet of Things  
5
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Figure 4. Nomenclature and Order Guide  
Sensing and Internet of Things  
6
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Figure 5. Electrical Connector Type Dimensions (For reference only: mm/[in].)  
“H”  
A
Metri-Pack 150, Standard  
(UL 94 HB)  
B
C
DIN  
Micro M12  
(IEC 61076-2)  
J
(EN 175301-803C)  
Metri-Pack 150  
(UL 94 V-0)  
Connector: DELPHI 12078088  
Connector: IEC 61076-2-101  
Connector: EN 175301-803C  
Mating Connector: EN 175301-803C  
DIN 43650C 8MM  
IP Rating1: IP65 (all versions)  
Mating Connector: DELPHI 12110192 Mating Connector: 4 POS TYPE D  
IP Rating1: IP65 (all versions)  
IP Rating1: IP65/IP67 (absolute, sealed  
gage versions) , IP65 (vented gage  
versions)  
Voltage  
Output  
Current  
Output  
Voltage  
Output  
Current  
Output  
Voltage  
Output  
Current  
Output  
Pin  
Pin  
Pin  
A
GND  
V+  
RTN  
1
3
V+  
supply  
RTN  
1
2
GND  
V+  
RTN  
supply  
NC  
B
supply  
GND  
3
Vout  
NC  
C
Vout  
NC  
4
Vout  
NC  
PE  
NC  
1
4
B
C
A
3
2
1
PE  
3
17,0  
[0.67]  
ø17,0  
[0.67]  
Hole  
(vented gage  
versions only)  
Hole  
(vented gage  
versions only)  
Hole  
(vented gage  
versions only)  
ø11,5  
[0.45]  
“H” = 46,0  
[1.81]  
“H” = 40,7  
“H” = 36,2  
[1.46]  
[1.60]  
1
IP rating is determined by the electrical connection chosen.  
Sensing and Internet of Things  
7
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Figure 5. Electrical Connector Type Dimensions (continued)  
“H”  
E Cable Harness, 1 Meter2  
D
F Cable Harness, 2 Meter2  
G Cable Harness, 3 Meter2, 3  
H Cable Harness, 5 Meter2, 3  
Deutsch  
(DTM04-3P)  
Connector: Deutsch DTM04-3P  
Mating Connector: DTM06-3S  
IP Rating1: IP65, IP67, IP69K (absolute,  
sealed gage versions), IP65 (vented gage  
versions)  
Connector: 24 AWG with TPE Jacket  
Mating Connector: Flying leads  
IP Rating1: IP65, IP67, IP69K (absolute, sealed gage versions)  
Voltage  
Output  
Current  
Output  
Voltage  
Output  
Current  
Output  
Pin  
Wire Color  
Wire Color  
1
2
3
GND  
Vout  
V+  
RTN  
NC  
red  
V+  
red  
supply  
black  
white  
GND  
Vout  
black  
RTN  
supply  
2
B
B
1
3
A
A
C
20,61  
[0.81]  
ø16,1  
ø16,1  
[0.63]  
[0.63]  
Hole  
(vented gage  
versions only)  
“H” = 55,0  
[2.16]  
“H” = 55,0  
[2.16]  
“H” = 51,2  
[2.01]  
1 IP rating is determined by the electrical connector type chosen.  
2 Three-wire cable is required for ratiometric and regulated outputs; two wire cable is required for current output.  
3 Three meter and five meter cables are only available with Output Transfer Function CH = Current, 4 mA to 20 mA.  
Sensing and Internet of Things  
8
Heavy Duty Pressure Transducers  
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi  
Figure 6. Pressure Port Type Dimensions (For reference only: mm/[in].)1  
22 Hex flat to flat  
[0.87]  
“P”  
F1 7/16-20 UNF 1/4 in 45º Flare Female Schrader (SAE J512) F2 7/16-20 UNF 45º Flare Male (SAE J513)  
Seal: 45º cone  
Seal: 45º cone  
Mating geometry: SAE J512  
Mating geometry: SAE J513  
Installation torque2: 17 N m [12.5 ft-lb]  
Installation torque2:1/4 Turn from finger tight  
“P” = 17,4  
[0.68]  
“P” = 19,2  
[0.75]  
12,3  
[0.49]  
12,3  
[0.49]  
F3 7/16-20 UNF 37º Flare Male (SAE J514)  
G1 G1/4 ( ISO 1179-3)  
Seal3,4: 37º cone  
Seal3,4: O-ring  
Mating Geometry: SAE J514  
Mating geometry: ISO 1179-1  
Installation Torque2: 16 N m [11.8 ft-lb]  
Installation torque2: 50 N m [38.9 ft-lb]  
“P” = 20,5  
[0.81]  
“P” = 16,2  
[0.64]  
11,2  
15,5  
[0.44]  
[0.61]  
G2 G1/8 (ISO 1179-3)  
M1 M12 X 1.5 (ISO 6149-3)  
Seal3,4: O-ring  
Seal2,3: O-ring  
Mating geometry: ISO 1179-1  
Mating geometry: ISO 6149-1  
Installation torque2: 25 N m [18.4 ft-lb]  
Installation torque2: 25 N m [18.4 ft-lb]  
“P” = 18,5  
“P” = 12,6  
[0.50]  
[0.73]  
13,5  
[0.53]  
7,6  
[0.30]  
N1 1/4–18 NPT  
Seal: pipe thread  
N2 1/8–27 NPT  
Seal: pipe thread  
Mating geometry: ANSI B1.20.1  
Installation torque2: 2 to 3 turns  
from finger tight  
Mating geometry: ANSI B1.20.1  
Installation torque2: 2 to 3 turns  
from finger tight  
“P” = 20,0  
[0.79]  
“P” = 15,0  
[0.59]  
15,0  
[0.59]  
10,0  
[0.39]  
S1 9/16–18 UNF (SAE J1926-3)  
S2 7/16–20 UNF (SAE J1926-3)  
Seal3,4: O-ring  
Seal3,4: O-ring  
Mating geometry: SAE J1926-1  
Mating geometry: SAE J1926-1  
Installation torque2: 30 N m [22.1 ft-lb]  
Installation torque2: 18 N m [12.3 ft-lb]  
“P” = 18,5  
[0.73]  
“P” = 17,5  
[0.69]  
13,5  
12,5  
[0.49]  
[0.53]  
1
2
3
4
See CAUTION “PRODUCT DAMAGE DUE TO MECHANICAL ISSUES” on page 5.  
Straight thread maximum torque is validated to 150ꢀ of installation torque.  
Seals for pressure port type order codes S1, S2, M1, G1 and G2 are included and assembled to the sensors.  
O-ring material is nitrile 70 durometer -30ºC to 125ºC [-22ºF to 257ºF].  
Sensing and Internet of Things  
9
ADDITIONAL INFORMATION  
The following associated literature is available on the  
Honeywell web site at sensing.honeywell.com:  
WARNING  
PERSONAL INJURY  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Product line guide  
Product range guide  
Product installation instructions  
Application notes:  
Failure to comply with these instructions could result in  
death or serious injury.  
- Heavy Duty Pressure Transducers, PX2 Series and PX3  
Series  
WARNING  
MISUSE OF DOCUMENTATION  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial Refrigeration  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial HVAC/R  
Applications  
• The information presented in this datasheet is for reference  
only. Do not use this document as a product installation  
guide.  
• Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
• Technical notes:  
- Total Error Band Specification for Honeywell Heavy  
Duty Pressure Transducers, PX2 Series and PX3 Series  
Failure to comply with these instructions could result in  
death or serious injury.  
- Media Compatibility for Honeywell Heavy Duty  
Pressure Transducers, PX2 Series and PX3 Series  
• CAD models  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free  
of defective materials and faulty workmanship during the  
applicable warranty period. Honeywell’s standard product  
warranty applies unless agreed to otherwise by Honeywell  
in writing; please refer to your order acknowledgement or  
consult your local sales office for specific warranty details.  
If warranted goods are returned to Honeywell during the  
period of coverage, Honeywell will repair or replace, at its  
option, without charge those items that Honeywell, in its sole  
discretion, finds defective. The foregoing is buyer’s sole  
remedy and is in lieu of all other warranties, expressed or  
implied, including those of merchantability and fitness for  
a particular purpose. In no event shall Honeywell be liable  
for consequential, special, or indirect damages.  
While Honeywell may provide application assistance  
personally, through our literature and the Honeywell web site, it  
is buyer’s sole responsibility to determine the suitability of the  
product in the application.  
Find out more  
Honeywell serves its customers through  
a worldwide network of sales offices and  
distributors. For application assistance,  
current specifications, pricing or name  
of the nearest Authorized Distributor,  
contact your local sales office.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this writing.  
However, Honeywell assumes no responsibility for its use.  
To learn more about Honeywell’s  
sensing and switching products, call  
+1.815.235.6847 or 1.800.537.6945,  
visit sensing.honeywell.com, or e-mail  
inquiries to info.sc@honeywell.com  
Honeywell Sensing and Internet of Things  
9680 Old Bailes Road  
500599462-I-EN | I | 06/17  
© 2017 Honeywell International Inc.  
Solstice® N40 is a registered trademark of Honeywell International Inc.  
Fort Mill, SC 29707  
www.honeywell.com  

相关型号:

PX2AN2XX250PSCHX

PX2 Series Heavy Duty Pressure Transducers, sealed gage, 0 psi to 250 psi, 8 V to 30 V input, 4 mA to 20 mA output, 1/8-27 NPT, Delphi Metri-Pack 150
HONEYWELL

PX2AS2XX100PAAAX

PX2 Series Heavy Duty Pressure Transducers, absolute, 0 psi to 100 psi, 4.75 V to 5.25 V input, ratiometric 5.0 Vdc 10 %Vs to 90 %Vs output, 7/16-20 UNF SAE J1926-3, Delphi Metri-Pack 150
HONEYWELL

PX2AS2XX100PACHX

PX2 Series Heavy Duty Pressure Transducers, absolute, 0 psi to 100 psi, 8 V to 30 V input, 4 mA to 20 mA output, 7/16-20 UNF SAE J1926-3, Delphi Metri-Pack 150
HONEYWELL

PX2C8H00

Dual-Line PID Controller
REDLION

PX2C8V00

Dual-Line PID Controller
REDLION

PX2EN1XX100PSAAX

PX2 Series Heavy Duty Pressure Transducers, sealed gage, 0 psi to 100 psi, 4.75 V to 5.25 V input, ratiometric 5.0 Vdc 10 %Vs to 90 %Vs, 1/4-18 NPT, Cable Harness (1 meter)
HONEYWELL

PX2FCA00

Field-Installable FlexCard Modules
REDLION

PX2FCA10

Field-Installable FlexCard Modules
REDLION

PX308

Heatsink For all isolated power modules
SEMIKRON

PX308/300F

Heatsink For all isolated power modules
SEMIKRON

PX314ZG/100

VERGUSSMASSEN EPOXY SW 100G
ETC

PX314ZG/1000

VERGUSSMASSEN EPOXY 1000G
ETC