SCC100AD2 [HONEYWELL]
Peizoresistive Sensor, Absolute, 0Psi Min, 100Psi Max, 0.5%, -10-155mV, Rectangular, Through Hole Mount, DIP-6;型号: | SCC100AD2 |
厂家: | Honeywell |
描述: | Peizoresistive Sensor, Absolute, 0Psi Min, 100Psi Max, 0.5%, -10-155mV, Rectangular, Through Hole Mount, DIP-6 传感器 换能器 |
文件: | 总4页 (文件大小:824K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SCC Series
Silicon pressure sensors
0 psi to 5 psi and 0 psi to 300 psi
DESCRIPTION
The SCC Series sensors offer an extremely low cost sensor
element with a temperature stable output when driven with a
constant current source. These integrated circuit sensors
were designed for extremely cost sensitive applications where
precise accuracy over a wide temperature range is not
required. This series is intended for use with non-corrosive,
non-ionic working fluids such as air, and dry gases.
Absolute devices have an internal vacuum reference and an
output voltage proportional to applied pressure. The
differential devices allow application of pressure to either side
of the diaphragm and devices are thereby available to
measure both differential and gage pressures.
This product is packaged either in standard low cost chip
carrier “button” package or a DIP package. Both packages
are designed for applications where the sensing element is to
be integral to the OEM equipment. These packages can be o-
ring sealed, epoxied, and/or clamped onto a pressure fitting.
A closed bridge four pin SIP configuration is provided for
electrical connection to the button package. The DIP package
offers a 5-pin open bridge configuration.
FEATURES
TYPICAL APPLICATIONS
• Low cost sensor element
• Pneumatic controls
• Automotive diagnostics
• Medical equipment
• Dental equipment
• Internal temperature compensation
• Differential or gage pressures
• Environmental controls
ORDERING INFORMATION
Part Number for Ordering
Pressure Range
Sensor in
Button Package
SCC05D
SCC015D
SCC30D
SCC100D
SCC15A
Sensor in
Sensor in
Nipple Package
SCC05DP1
SCC015DP1
SCC30DP1
–
Sensor in
DIP Package
“N” Package
SCC05DN
SCC015DN
SCC30DN
SCC100DN
SCC15AN
SCC30AN
SCC100AN
–
0 psid to 5 psid or psig
0 psid to 15 psid or psig
0 psid to 30 psid or psig
0 psig to 100 psig
0 psia to 15 psia
SCC05GD2, SCC05DD4
SCC15GD2, SCC15DD4
SCC30GD2, SCC30DD4
SCC100GD2, SCC100DD4
SCC15AD2
SCC15AP1
SCC30AP1
–
0 psia to 30 psia
SCC30A
SCC30AD2
0 psia to 100 psia
SCC100A
–
SCC100AD2
0 psia to 300 psi
–
–
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
WARNING
PERSONAL INJURY
• Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
SCC Series
SPECIFICATION CHARACTERISTICS (Maximum Ratings for All Devices)
Supply current, IS
1.5 mA
Compensated temperature range
Operating temperature range
Storage temperature range
Humidity
0 °C to 50 °C [32 °F to 122 °F]
-40 °C to 85 °C [-40 °F to 185 °F]
-55 °C to 125 °C [-67 °F to 257 °F]
0 % to 100 % RH
Lead temperature
250 °C [482 °F] Soldering 2 sec to 4 sec
150 psi
Common-mode pressure
PERFORMANCE CHARACTERISTICS (Individual Models) Is=1.0 mA, TA=25 °C [77 °F](1)
Effect (3, 4)
Effect(5, 4)
on Offset
0 °C to 50 °C
30 µV/°C
40 µV/°C
40 µV/°C
60 µV/°C
30 µV/°C
90 µV/°C
50 µV/°C
Full-Scale
Span(6)
mV
Part
Operating
Maximum
Over Pressure
20 psi
on Span
0 °C to 50 °C
1.50 %
Number
Pressure Range
0 psid to 5 psid (g)
0 psia to 15 psia
0 psid to 15 psid (g)
0 psid to 30 psid (g)
0 psia to 100 psia
0 psig to 100 psig
0 psia to 300 psia
Accuracy(2)
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
SCC05(D,G)
SCC15A
25-65
30 psia
1.50 %
40-95
SCC15(D,G)
SCC30(D,G)
SCC100A
SCC100(D,G)(7)
SCC300A
30 psi
1.50 %
40-95
60 psi
1.50 %
60-150
85-225
85-225
50-120
150 psia
150 psig
450 psia
1.50 %
1.50 %
1.50 %
PERFORMANCE SPECIFICATIONS (All Models) Is=10.0 Ma, Ta=25 °C [77 °F]
Min.
-30.0
–
Typ.
-10.0
0.25
0.10
0.10
5.00
5.00
Max.
20.0
0.50
–
Unit
Zero Pressure Offset(8)
mV
% FSO
mV
Combined Linearity, Hysteresis and Repeatability(2)
Long Term Stability of Offset and Span(9)
Response Time (10 % to 90 %)(10)
Input Impedance
–
–
–
ms
4.00
4.00
6.50
6.50
kOhm
kOhm
Output Impedance
Specification Notes:
Note 1: Reference Conditions; Supply Current = 1.0 mA;TA = 25 °C [77 °F], Common-mode Line Pressure = 0 psig, Pressure Applied to P1, unless otherwise noted.
Note 2: Accuracy is the sum of Hysteresis and Linearity. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and ½ full-scale pressure at 25 °C [77 °F].
Note 3: This is the maximum temperature shift for span when measured between 0 °C and 50 °C [32 °F to 122 °F] relative to the 25 °C [77 °F] reading.Typical
temperature coefficients for span and resistance are -2200 ppm/°C and 2200 ppm/°C respectively.
Note 4: Temperature effect on span and offset are guaranteed by design.Therefore these parameters are not 100 % tested.
Note 5: This is the maximum temperature shift for offset when measured at 0 °C and 50 °C [32 °F to 122 °F] divided by the temperature difference.
Note 6: Span is the algebraic difference between the output voltage at full-scale pressure and the ouput at zero pressure.
Note 7: The SCC100D devices can only be used in a forward gauge mode. Application of more than 30 psig to the back side of any of the SCC Series devices can result
in device failure. On the SCC100GD2 pressure can only be applied to the back side of the die. No pressure I accessible from the front/top side of die.
Note 8: The zero pressure offset is 30 to -20 mV max. form parts SCCxxxGD2 and SCCxxDD4 devices.
Note 9: Maximum difference in output at any pressure with the operating pressure range and temperature within 0 °C and 50 °C [32 °F to 122 °F].
a) 100 temperature cycles, 0 °C and 50 °C [32 °F to 122 °F]
b) 1.0 million pressure cycles, 0 psi to full-scale span.
Note 10: Response time for a 0 psi to full-scale span pressure step change. 10 % to 90 % rise time.
2
www.honeywell.com/sensing
Silicon pressure sensors
ELECTRICAL CONNECTIONS
(+Vo)
(V )
s
EQUIVALENT CIRCUITS
MOUNTING DIMENSIONS IN MM (INCHES), FOR REFERENCE ONLY
Button package
V
s
3
2
+
OUTPUT
4
-
1
GND
Button, Nipple and “N” Packages
V
s
4
5
Nipple package
1
-
OUTPUT
3
+
2
GND
DIP Packages
N Housing package
Honeywell Sensing and Control
3
D2 DIP package
DD4 DIP package
AD4 DIP package
WARRANTY/REMEDY
SALES AND SERVICE
Honeywell warrants goods of its
merchantability and fitness for a
Honeywell serves its customers through
a worldwide network of sales offices,
representatives and distributors. For
application assistance, current
specifications, pricing or name of the
nearest Authorized Distributor, contact
your local sales office or:
manufacture as being free of defective
materials and faulty workmanship.
Honeywell’s standard product warranty
applies unless agreed to otherwise by
Honeywell in writing; please refer to
your order acknowledgement or consult
your local sales office for specific
warranty details. If warranted goods are
returned to Honeywell during the period
of coverage, Honeywell will repair or
replace, at its option, without charge
those items it finds defective. The
foregoing is buyer’s sole remedy and
is in lieu of all warranties, expressed
or implied, including those of
par
ticular purpose. In no event shall
Honeywell be liable for
consequential, special, or indirect
damages.
While we provide application
assistance personally, through our
literature and the Honeywell web site, it
is up to the customer to determine the
suitability of the product in the
application.
Specifications may change without
notice. The information we supply is
believed to be accurate and reliable as
of this printing. However, we assume no
responsibility for its use.
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Automation and Control Solutions
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032, USA
www.honeywell.com
008135-2-EN IL50 GLO
May 2005
Copyright 2004-2005 Honeywell International Inc.