SS349RT [HONEYWELL]
Unipolar Hall-Effect Digital Position Sensors; 单极霍尔效应数字式位置传感器型号: | SS349RT |
厂家: | Honeywell |
描述: | Unipolar Hall-Effect Digital Position Sensors |
文件: | 总4页 (文件大小:437K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SS340RT and SS440R
Series
Unipolar Hall-Effect Digital
Position Sensors
DESCRIPTION
These sensors are available in two package styles. The
SS340RT Series is available in the miniature SOT-23 surface
mount package; the SS440R is available in the leaded, flat TO-
92-style package. The SS340RT’s small size requires less PC
board space, allowing it to be used in smaller assemblies. Its
3 V capability allows for use in low voltage applications,
promoting energy efficiency.
The SS340RT Series and SS440R Series sensors are small,
versatile digital Hall-effect devices that are operated by the
magnetic field from a permanent magnet or an electromagnet.
They are designed to respond to a single pole: North
(SS340RT Series) or South (SS440R Series).
These unipolar sensors are supplied in three different magnetic
sensitivities to meet a wide range of potential applications. The
SS341RT and SS441R offer the highest sensitivity, with a
typical operating point of 85 G at 25 °C [77 °F]; the SS343RT
and SS443R offer medium sensitivity with 125 G typical at
25 °C [77 °F]; the SS349RT and SS449R offer the lowest
sensitivity, requiring 350 G typical to operate at 25 °C [77 °F].
The SS340RT Series is available on tape and reel (3000 units
per reel); the SS440R Series is available in a bulk package
(1000 units per bag).
FEATURES/BENEFITS
POTENTIAL APPLICATIONS
•
Subminiature package size (SS340RT Series) supplied on
tape and reel allows for a compact design with automated
component placement, helping to reduce manufacturing
costs
Simple activation from a single pole and multiple magnetic
sensitivities (high, medium and low) make this product
suitable in a variety of potential motion control, lid closure
detection, and displacement sensing applications
Low voltage 3 V capability helps reduce power
consumption
Built-in reverse polarity protection protects the device from
potential damage during installation
Thermally balanced integrated circuit provides for stable
operation over a wide temperature range, from -40 °C to
150 °C [-40 °F to 302 °F]
•
•
Door or lid closure detection
Speed and RPM (revolutions per minute) sensing in
fitness equipment
Flow rate sensing in industrial processes, appliances, or
water softeners
Damper or valve position control in industrial, HVAC or
residential or commercial applications
Robotic control (cylinder position monitoring)
Float-based fluid level sensing
Displacement sensor in hospital beds or medical
equipment
Medication bin monitor on portable drug carts
Printer head position sensing
•
•
•
•
•
•
•
•
•
•
•
•
RoHS-compliant materials meet Directive 2002/95/EC
SS340RT and SS440R Series
Table 1. SS340RT and SS440R Series Specifications (At Vs=3.0 to 24 Vdc, 20 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 257 ºF])
Characteristic
Supply voltage:1
SS440R Series
SS340RT Series
SS340RT Series
Supply current
Condition
Minimum
Typical
Maximum
Unit
-40 °C to 150 °C [-40 °F to 302 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
150 °C [302 °F]
Vsupply = 5 V at 25 °C [77 °F]
Vsupply = 3 V at 25 °C [77 °F]
3
3
3
–
–
–
–
–
–
4
3.5
–
24
24
12
6
5
8
Vdc
mA
Vsat
at 20 mA, gauss >Bop
gauss >Bop
–
–
–
–
0.4
10
Vdc
µA
Output leakage current
Output switching time:
rise
Vsupply = 12 V at 25 °C [77 °F],
RL =1.6 kOhm, CL = 20 pF
–
–
–
–
1.5
1.5
µs
fall
Thermal resistance:
SS440R Series
SS340RT Series
Operate:
SS341RT/SS441R
SS343RT/SS443R
SS349RT/SS449R
Release:
SS341RT/SS441R
SS343RT/SS443R
SS349RT/SS449R
Differential:
SS341RT/SS441R
SS343RT/SS443R
SS349RT/SS449R
–
–
–
–
°C/W
233
303
35
45
240
85
125
350
135
205
460
gauss
gauss
gauss
10
40
135
50
90
250
120
180
370
–
–
5
5
30
35
35
100
80
120
170
Operating temperature
Storage temperature
Note 1. See Figure 1.
–
–
-40 [-40]
-40 [-40]
–
–
150 [302]
150 [302]
°C [°F]
°C [°F]
Table 2. SS340RT and SS440R Series Absolute Maximum Ratings1
Characteristic
Supply voltage
Applied output voltage
Output current
Minimum
Typical
Maximum
28.0
28.0
20
no limit
Unit
V
V
mA
gauss
-28.0
-0.5
–
–
–
–
–
Magnetic flux
–
Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified in the magnetic
characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a uniform magnetic field.
NOTICE
Absolute maximum ratings are the extreme limits that the device will withstand without
damage to the device. However, the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Figure 1. SS340RT Series Rated Supply Voltage
Figure 2. Current Sinking Output Block Diagram
2
www.honeywell.com/sensing
Unipolar Hall-Effect Digital Position Sensors
Figure 3. Wiring Diagrams
Figure 4. SS340RT Series Mounting/Tape and Reel Dimensions (For reference only. mm/[in])
Figure 5. SS440R Series Mounting Dimensions (For reference only. mm/[in])
Honeywell Sensing and Control
3
Order Guide
Catalog Listing
SS341RT
Description
SS340RT Series, unipolar, Hall-effect digital position sensor, high sensitivity, SOT-23 package, tape and
reel packaging (3000 units per reel)
SS343RT
SS349RT
SS441R
SS443R
SS449R
SS340RT Series, unipolar, Hall-effect digital position sensor, medium sensitivity, SOT-23 package, tape and
reel packaging (3000 units per reel)
SS340RT Series, unipolar, Hall-effect digital position sensor, low sensitivity, SOT-23 package, tape and reel
packaging (3000 units per reel)
SS440R Series, unipolar, Hall-effect digital position sensor, high sensitivity, flat TO-92 package, bulk
packaging (1000 units per bag)
SS440R Series, unipolar, Hall-effect digital position sensor, medium sensitivity, flat TO-92 package, bulk
packaging (1000 units per bag)
SS440R Series, unipolar, Hall-effect digital position sensor, low sensitivity, flat TO-92 package, bulk
packaging (1000 units per bag)
WARNING
PERSONAL INJURY
WARNING
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
•
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Failure to comply with these instructions could result
in death or serious injury.
•
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
+1-305-805-8188
+1-305-883-8257 Fax
+1-800-537-6945
Europe
Latin America
USA/Canada
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
005909-1-EN IL50 GLO Printed in USA
September 2009
© 2009 Honeywell International Inc. All rights reserved.
Golden Valley, MN 55422
www.honeywell.com/sensing
©2020 ICPDF网 联系我们和版权申明