SSCSANN060MD7A5 [HONEYWELL]

Peizoresistive Sensor, Differential, -.87Psi Min, 0.87Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4;
SSCSANN060MD7A5
型号: SSCSANN060MD7A5
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Differential, -.87Psi Min, 0.87Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4

传感器 换能器 压力传感器
文件: 总12页 (文件大小:1201K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
These sensors measure absolute, differential, and gage  
pressures. The absolute versions have an internal vacuum  
reference and an output value proportional to absolute  
pressure. Differential versions allow application of pressure to  
either side of the sensing diaphragm. Gage versions are  
referenced to atmospheric pressure and provide an output  
proportional to pressure variations from atmosphere.  
DESCRIPTION  
The TruStability Standard Accuracy Silicon Ceramic (SSC)  
Series is a piezoresistive silicon pressure sensor offering a  
digital output for reading pressure over the specified full scale  
pressure span and temperature range.  
The SSC Series is fully calibrated and temperature  
compensated for sensor offset, sensitivity, temperature effects,  
and non-linearity using an on-board Application Specific  
Integrated Circuit (ASIC). Calibrated output values for pressure  
are updated at approximately 2 kHz.  
The TruStability® pressure sensors are intended for use with  
non-corrosive, non-ionic gases, such as air and other dry  
gases. An available option extends the performance of these  
sensors to non-corrosive, non-ionic liquids.  
The SSC Series is calibrated over the temperature range of  
-20 C to 85 C [-4 F to 185 F]. The sensor is characterized  
for operation from a single power supply of either 3.3 Vdc or  
5.0 Vdc.  
All products are designed and manufactured according to ISO  
9001 standards.  
FEATURES  
Industry-leading long-term stability  
Extremely tight accuracy of 0.25% FSS BFSL (Full Scale  
Span Best Fit Straight Line)  
Precision ASIC conditioning and temperature compensated  
over -20 C to 85 C [-4 F to 185 F] temperature range  
RoHS compliant  
Total error band of 2% full scale span maximum  
Modular and flexible design offers customers a variety of  
package styles and options, all with the same industry-  
leading performance specifications  
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package  
Low operating voltage  
Virtually insensitive to mounting orientation  
Internal diagnostic functions increase system reliability  
Also available with analog output  
Absolute, differential, and gage types  
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)  
Custom calibration available  
Extremely low power consumption  
Various pressure port options  
Liquid media option  
I2C- or SPI- compatible 14-bit digital output (min. 12-bit  
sensor resolution)  
POTENTIAL APPLICATIONS  
Medical:  
Industrial:  
-
-
-
-
-
-
-
-
-
-
-
Airflow monitors  
-
-
-
-
-
-
-
Barometry  
Anesthesia machines  
Blood analysis machines  
Gas chromatography  
Gas flow instrumentation  
Kidney dialysis machines  
Oxygen concentrators  
Pneumatic controls  
Respiratory machines  
Sleep apnea equipment  
Ventilators  
Flow calibrators  
Gas chromatography  
Gas flow instrumentation  
HVAC  
Life sciences  
Pneumatic controls  
Table 1. Absolute Maximum Ratings1  
Parameter  
Min.  
-0.3  
-0.3  
Max.  
6.0  
Unit  
Vdc  
V
Supply voltage (Vsupply)  
Voltage on any pin  
Digital interface clock frequency:  
I2C  
Vsupply + 0.3  
100  
50  
400  
800  
kHz  
SPI  
ESD susceptibility (human body model)  
Storage temperature  
Soldering time and temperature:  
Lead solder (SIP, DIP)  
Peak reflow (SMT)  
3
kV  
-40 [-40]  
85 [185]  
C [ F]  
4 s max. at 250 °C [482 °F]  
15 s max. at 250 °C [482 °F]  
Table 2. Operating Specifications  
Parameter  
Min.  
Typ.  
Max.  
Unit  
Supply voltage (Vsupply)2:  
3.3 Vdc  
3.0  
4.75  
3.33  
5.03  
3.6  
5.25  
Vdc  
5.0 Vdc  
Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.  
Supply current:  
3.3 Vdc supply  
5.0 Vdc supply  
1.6  
2
2.1  
3
mA  
-
Compensated temperature range4  
Operating temperature range5  
Startup time (power up to data ready)  
Response time  
-20 [-4]  
-40 [-40]  
85 [185]  
85 [185]  
7.3  
C [ F]  
C [ F]  
ms  
2.8  
0.46  
ms  
I2C voltage level low  
I2C voltage level high  
Pull up on SDA and SCL  
Accuracy6  
-
0.8  
1
-
-
-
0.2  
Vsupply  
Vsupply  
kOhm  
%FSS BFSL  
%FSS8  
bits  
-
-
0.25  
2
Total error band7  
Output resolution  
12  
2
www.honeywell.com/sensing  
Table 3. Environmental Specifications  
Parameter  
Characteristic  
Humidity:  
Dry gases only (See “Options N and D” in Figure 1.)  
Liquid media (See “Options T and V” in Figure 1.)  
0% to 95% RH, non-condensing  
100% condensing or direct liquid media on Port 1  
MIL-STD-202F, Curve AK (20.7 g random)  
MIL-STD-202F, Method 213B, Condition F  
1 million cycles minimum  
Vibration  
Shock  
Life9  
Solder reflow  
J-STD-020-C  
Table 4. Wetted Materials10  
Parameter  
Covers  
Port 1 (Pressure Port)  
high temperature polyamide  
alumina ceramic  
Port 2 (Reference Port)  
high temperature polyamide  
alumina ceramic  
Substrate  
Adhesives  
epoxy, silicone  
epoxy, silicone  
Electronic components  
Notes:  
ceramic, glass, solder, silicon  
silicon, glass, gold, solder  
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.  
2. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved  
within the specified operating voltage for each option.  
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.  
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within  
the specified performance limits.  
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not  
remain within the specified performance limits.  
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at  
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.  
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.  
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal  
effect on span, and thermal hysteresis.  
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of  
the pressure range. (See Figure 1 for ranges.)  
9. Life may vary depending on specific application in which sensor is utilized.  
10. Contact Honeywell Customer Service for detailed material information.  
CAUTION  
PRODUCT DAMAGE  
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.  
Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate  
inside the sensor, causing damage or affecting sensor output.  
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to  
enter and settle within the pressure sensor if it is in this position.  
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a  
dead-ended sensor is difficult and has limited effectiveness for removing residue.  
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and  
may lead to sensor failure.  
Failure to comply with these instructions may result in product damage.  
Honeywell Sensing and Control  
3
Figure 1. Nomenclature and Order Guide  
_
_ _ _ _ _ _ _ _  
_
_
A
SSC  
Supply Voltage  
3 = 3.3 Vdc  
Series  
5 = 5.0 Vdc  
Package  
D = DIP (Dual Inline Pin)  
M = SMT (Surface Mount Technology)  
S = SIP (Single Inline Pin)  
Transfer Function11  
A = 10% to 90% of Vsupply  
Output Type12  
S = SPI (not available in SIP package)  
2 = I2C, Address 0x28  
3 = I2C, Address 0x38  
4 = I2C, Address 0x48  
5 = I2C, Address 0x58  
6 = I2C, Address 0x68  
7 = I2C, Address 0x78  
Pressure Port (* indicates not available)  
SMT  
DIP  
SIP  
NN = No ports  
NN = No ports  
NN = No ports  
Pressure Range13, 14  
AA = Dual axial  
barbed ports,  
opposite sides  
*
*
1 psi to 150 psi  
60 mbar to 10 bar  
Absolute  
AN = Single  
axial barbed  
port  
AN = Single  
axial barbed  
port  
AN = Single  
axial barbed  
port  
015PA = 0 psi to 15 psi  
030PA = 0 psi to 30 psi  
060PA = 0 psi to 60 psi  
100PA = 0 psi to 100 psi  
150PA = 0 psi to 150 psi  
Absolute  
001BA = 0 bar to 1 bar  
1.6BA = 0 bar to 1.6 bar  
2.5BA = 0 bar to 2.5 bar  
004BA = 0 bar to 4 bar  
006BA = 0 bar to 6 bar  
010BA = 0 bar to 10 bar  
LN = Single  
axial barbless  
port  
LN = Single  
axial barbless  
port  
LN = Single  
axial barbless  
port  
Differential  
001PD = ±1 psi  
005PD = ±5 psi  
015PD = ±15 psi  
030PD = ±30 psi  
060PD = ±60 psi  
FF = Fastener  
mount, dual axial  
barbed ports,  
opposite sides  
Differential  
060MD = ±60 mbar  
100MD = ±100 mbar  
160MD = ±160 mbar  
250MD = ±250 mbar  
400MD = ±400 mbar  
600MD = ±600 mbar  
001BD = ±1 bar  
*
*
FN = Fastener  
mount, single axial  
barbed port  
Gage  
001PG = 0 psi to 1 psi  
005PG = 0 psi to 5 psi  
015PG = 0 psi to 15 psi  
030PG = 0 psi to 30 psi  
060PG = 0 psi to 60 psi  
100PG = 0 psi to 100 psi  
150PG = 0 psi to 150 psi  
*
*
*
*
*
1.6BD = ±1.6 bar  
2.5BD = ±2.5 bar  
004BD = ±4 bar  
GN = Ribbed  
fastener mount,  
single axial  
barbed port  
Gage  
NB = Fastener  
mount, dual axial  
ports, same side  
060MG = 0 mbar to 60 mbar  
100MG = 0 mbar to 100 mbar  
160MG = 0 mbar to 160 mbar  
250MG = 0 mbar to 250 mbar  
400MG = 0 bar to 400 mbar  
600MG = 0 bar to 600 mbar  
001BG = 0 bar to 1 bar  
1.6BG = 0 bar to 1.6 bar  
2.5BG = 0 bar to 2.5 bar  
004BG = 0 bar to 4 bar  
006BG = 0 bar to 6 bar  
010BG = 0 bar to 10 bar  
*
RN = Single  
radial barbed  
port  
RN = Single  
radial barbed  
port  
RN = Single  
radial barbed  
port  
RR = Dual radial  
barbed ports,  
same side  
RR = Dual radial  
barbed ports,  
same side  
RR = Dual radial  
barbed ports,  
same side  
DR = Dual radial  
barbed ports,  
opposite sides  
DR =Dual radial  
barbed ports,  
opposite sides  
DR = Dual radial  
barbed ports,  
opposite sides  
Options15  
N = Dry gases only, no special options  
D = Dry gases only, diagnostics on  
T = Liquid media on port 1, no diagnostics  
V = Liquid media on port 1, diagnostics on  
HH = Fastener  
mount, dual  
radial barbed  
ports, same side  
*
*
*
*
HN = Fastener  
mount, single  
radial barbed  
port  
MN = Manifold  
mount, outer  
diameter seal  
*
*
*
*
SN = Manifold  
mount, inner  
diameter seal  
Notes:  
11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and  
Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other  
transfer functions are available. Contact Honeywell Customer Service for more information.  
12. Analog output is also available. Contact Honeywell Customer Service for more information.  
13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information.  
14. See Table 5 for an explanation of sensor pressure types.  
15. See CAUTION on previous page.  
4
www.honeywell.com/sensing  
Figure 2. Transfer Function Limits  
Figure 3. Completed Catalog Listing Example  
SSCSANN100PGSA3  
SIP package, AN pressure  
port, no diagnostics, 100  
psi gage, SPI output, 10%  
to 90% calibration at  
3.3 Vdc.  
Table 5. Pressure Types  
Pressure Type  
Description  
Output is proportional to the difference between applied pressure and a built-in reference to vacuum.  
Pmin. is set at absolute zero pressure (full vacuum).  
Absolute  
Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2)  
50% point of transfer function set at Port 1 = Port 2.  
Output is proportional to the difference between applied pressure and atmospheric (ambient)  
pressure. Pmin. is set at atmospheric pressure.  
Differential  
Gage  
Table 6. Sensor Output at Significant Percentages  
% Output  
Digital Counts (decimal)  
Digital Counts (hex)  
0x0000  
0
0
10  
50  
90  
100  
1638  
8192  
14746  
16383  
0x0666  
0x2000  
0x399A  
0x3FFF  
Table 7. Pressure Range Specifications for 1 psi to 150 psi  
Long-term  
Stability  
(1000 hr,  
Pressure Range  
Order Code  
Over-  
Burst  
Common Mode  
Pressure18  
pressure16  
Pressure17  
Pmin.  
Pmax.  
25 °C [77 °F])  
Absolute  
30 psi  
60 psi  
120 psi  
250 psi  
250 psi  
Differential  
10 psi  
30 psi  
30 psi  
60 psi  
120 psi  
Gage  
0 psi  
0 psi  
0 psi  
0 psi  
0 psi  
15 psi  
30 psi  
60 psi  
100 psi  
150 psi  
60 psi  
120 psi  
240 psi  
250 psi  
250 psi  
NA  
NA  
NA  
NA  
NA  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
015PA  
030PA  
060PA  
100PA  
150PA  
-1 psi  
-5 psi  
-15 psi  
-30 psi  
-60 psi  
1 psi  
5 psi  
15 psi  
30 psi  
60 psi  
10 psi  
40 psi  
60 psi  
120 psi  
240 psi  
150 psi  
150 psi  
150 psi  
150 psi  
250 psi  
0.35% FSS  
0.35% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
001PD  
005PD  
015PD  
030PD  
060PD  
0 psi  
0 psi  
0 psi  
0 psi  
0 psi  
0 psi  
0 psi  
1 psi  
5 psi  
10 psi  
30 psi  
30 psi  
60 psi  
120 psi  
250 psi  
250 psi  
10 psi  
40 psi  
60 psi  
120 psi  
240 psi  
250 psi  
250 psi  
150 psi  
150 psi  
150 psi  
150 psi  
250 psi  
250 psi  
250 psi  
0.35% FSS  
0.35% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
001PG  
005PG  
015PG  
030PG  
060PG  
100PG  
150PG  
15 psi  
30 psi  
60 psi  
100 psi  
150 psi  
Honeywell Sensing and Control  
5
Table 8. Pressure Range Specifications for 60 mbar to 10 bar  
Pressure Range  
Long-term  
Stability  
(1000 hr,  
Over-  
Burst  
Common Mode  
Pressure18  
Order Code  
pressure16  
Pressure17  
Pmin.  
Pmax.  
25 C [77 F])  
Absolute  
2 bar  
4 bar  
6 bar  
8 bar  
17 bar  
17 bar  
Differential  
500 mbar  
500 mbar  
500 mbar  
1.4 bar  
1.4 bar  
2 bar  
0 bar  
0 bar  
0 bar  
0 bar  
0 bar  
0 bar  
1 bar  
1.6 bar  
2.5 bar  
4 bar  
6 bar  
10 bar  
4 bar  
8 bar  
8 bar  
16 bar  
17 bar  
17 bar  
NA  
NA  
NA  
NA  
NA  
NA  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
001BA  
1.6BA  
2.5BA  
004BA  
006BA  
010BA  
-60 mbar  
-100 mbar  
-160 mbar  
-250 mbar  
-400 mbar  
-600 mbar  
-1 bar  
-1.6 bar  
-2.5 bar  
-4 bar  
60 mbar  
100 mbar  
160 mbar  
250 mbar  
400 mbar  
600 mbar  
1 bar  
1.6 bar  
2.5 bar  
4 bar  
700 mbar  
700 mbar  
700 mbar  
2.5 bar  
2.5 bar  
4 bar  
4 bar  
8 bar  
8 bar  
16 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
060MD  
100MD  
160MD  
250MD  
400MD  
600MD  
001BD  
1.6BD  
2 bar  
4 bar  
6 bar  
8 bar  
2.5BD  
004BD  
Gage  
0 mbar  
0 mbar  
0 mbar  
0 mbar  
0 mbar  
0 mbar  
0 bar  
0 bar  
0 bar  
0 bar  
0 bar  
60 mbar  
100 mbar  
160 mbar  
250 mbar  
400 mbar  
600 mbar  
1 bar  
1.6 bar  
2.5 bar  
4 bar  
500 mbar  
500 mbar  
500 mbar  
1.4 bar  
1.4 bar  
2 bar  
2 bar  
4 bar  
6 bar  
8 bar  
700 mbar  
700 mbar  
700 mbar  
2.5 bar  
2.5 bar  
4 bar  
4 bar  
8 bar  
8 bar  
3.5 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
10 bar  
16 bar  
17 bar  
17 bar  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.35% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
0.25% FSS  
060MG  
100MG  
160MG  
250MG  
400MG  
600MG  
001BG  
1.6BG  
2.5BG  
004BG  
006BG  
010BG  
16 bar  
17 bar  
17 bar  
6 bar  
10 bar  
17 bar  
17 bar  
0 bar  
Notes:  
16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to  
the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this  
applies to all available pressure ports at any temperature with the operating temperature range.  
17. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product  
should not be expected to function after exposure to any pressure beyond the burst pressure.  
18. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without  
causing changes in specified performance.  
Table 9. Pinout for SMT and DIP Packages  
Output Type  
Pin 1  
GND  
GND  
Pin 2  
Vsupply  
Vsupply  
Pin 3  
SDA  
Pin 4  
SCL  
Pin 5  
NC  
Pin 6  
NC  
Pin 7  
NC  
Pin 8  
NC  
I2C  
SPI  
MISO  
SCLK  
SS  
NC  
NC  
NC  
Table 10. Pinout for SIP Package  
Output Type  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
I2C  
GND  
Vsupply  
SDA  
SCL  
6
www.honeywell.com/sensing  
Figure 4. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])  
DIP NN: No ports  
DIP AN: Single axial barbed port  
13,75  
0,25  
[0.010]  
0,25  
10,0  
[0.39]  
[0.541]  
5,44  
[0.214]  
[0.010]  
10,0  
[0.39]  
8
7
6
5
8
7
6
5
7,95  
[0.313]  
6,2  
[0.24]  
13,35  
[0.525]  
13,35  
[0.525]  
6,99  
[0.275]  
6,99  
[0.275]  
4,93 DIA.  
[0.194]  
PORT 2  
PORT 1  
PORT 2  
PORT 1  
1
2
3
4
1
2
3
4
9,24  
[0.364]  
11,21  
[0.441]  
9,24  
[0.364]  
10,85  
[0.427]  
2,54 TYP.  
[0.100]  
2,54 TYP.  
[0.100]  
8X 0,46  
[0.018]  
8X 0,46  
[0.018]  
DIP LN: Single axial barbless port  
DIP RN: Single radial barbed port  
5,80  
0,25  
0,25  
[0.010]  
[0.228]  
[0.010]  
5,80  
[0.228]  
10,0  
[0.39]  
10,0  
[0.39]  
8
7
6
5
8
7
6
5
2,47 DIA.  
[0.097]  
4,2  
[0.17]  
13,35  
[0.525]  
13,35  
[0.525]  
6,99  
[0.275]  
6,99  
[0.275]  
PORT 1  
PORT 2  
PORT 2  
PORT 1  
1,93 DIA.  
[0.076]  
1
2
3
4
1
2
3
4
9,24  
[0.364]  
9,24  
[0.364]  
2,54 TYP.  
[0.100]  
2,54 TYP.  
[0.100]  
11,21  
[0.441]  
11,21  
[0.441]  
13,75  
[0.541]  
6,95  
[0.274]  
1,00  
[0.039]  
8X 0,46  
[0.018]  
8X 0,46  
[0.018]  
DIP RR: Dual radial barbed ports, same side  
DIP DR: Dual radial barbed ports, opposite sides  
,25  
0,25  
15,76  
[0.620]  
10,0  
[0.39]  
6,16  
[0.242]  
6,16  
[0.242]  
[0.010]  
[0.010]  
10,0  
[0.39]  
4,0  
[0.16]  
8
7
6
5
2X 1,93 DIA.  
[0.076]  
2X 1,93 DIA.  
[0.076]  
8
7
6
5
13,35  
PORT 1  
PORT 2  
13,35  
[0.525]  
[0.525]  
6,99  
[0.275]  
6,99  
PORT 2  
[0.275]  
PORT 1  
PORT 1  
PORT 2  
4,65  
[0.183]  
PORT 1  
PORT 2  
1
2
3
4
9,24  
[0.364]  
9,24  
[0.364]  
2,54 TYP.  
[0.100]  
1
2
3
4
11,21  
[0.441]  
2,54 TYP.  
[0.100]  
11,21  
[0.441]  
3,78  
[0.149]  
3,78  
[0.149]  
8X 0,46  
[0.018]  
8X 0,46  
[0.018]  
Honeywell Sensing and Control  
7
Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])  
SMT NN: No ports SMT AN: Single axial barbed port  
10,0  
[0.39]  
13,75  
[0.541]  
5,44  
[0.214]  
10,0  
[0.39]  
8
7
6
5
8
7
6
5
7,95  
[0.313]  
13,4  
[0.53]  
6,99  
[0.275]  
PORT 1  
PORT 2  
13,4  
[0.53]  
4,93 DIA.  
[0.194]  
6,99  
[0.275]  
PORT 2  
PORT 1  
1
2
3
4
8X 0,46  
[0.018]  
4,80  
2,54 TYP.  
[0.100]  
1
2
3
4
[0.189]  
4,80  
[0.189]  
8X 0,46  
[0.018]  
6,41  
[0.252]  
2,54 TYP.  
[0.100]  
6,77  
[0.266]  
SMT LN: Single axial barbless port  
SMT RN: Single radial barbed port  
5,80  
[0.228]  
5,80  
[0.228]  
10,0  
[0.39]  
10,0  
[0.394]  
8
7
6
5
8
7
6
5
4,2  
[0.17]  
2,47 DIA.  
[0.097]  
13,3  
[0.53]  
13,35  
[0.525]  
6,99  
[0.275]  
6,99  
[0.275]  
PORT 1  
PORT 1  
PORT 2  
PORT 2  
1,93 DIA.  
[0.076]  
PORT 1  
1
2
3
4
4,80  
8X 0,46  
[0.018]  
1
2
3
4
4,80  
8X 0,46  
[0.018]  
2,54 TYP.  
[0.100]  
[0.189]  
2,54 TYP.  
[0.100]  
[0.189]  
6,77  
[0.266]  
6,77  
[0.266]  
13,75  
[0.541]  
SMT RR: Dual radial barbed ports, same side  
SMT DR: Dual radial barbed ports, opposite sides  
10,0  
[0.39]  
15,8  
6,16  
[0.242]  
[0.62]  
4,0  
[0.16]  
10,0  
[0.39]  
6,16  
[0.242]  
8
7
6
5
2X 2,93  
[0.115]  
2X 1,93 DIA.  
[0.076]  
8
7
6
5
13,35  
[0.525]  
PORT 1  
PORT 2  
6,99  
[0.275]  
13,4  
[0.53]  
PORT 1  
PORT 2  
2X 1,93 DIA.  
[0.076]  
6,99  
[0.275]  
4,6  
[0.18]  
PORT 2  
PORT 1  
1
2
3
4
4,80  
8X 0,46  
[0.018]  
1
2
3
4
2,54 TYP.  
[0.100]  
[0.189]  
4,80  
8X 0,46  
[0.018]  
2,54 TYP.  
[0.100]  
[0.189]  
6,77  
[0.266]  
6,77  
[0.266]  
3,78  
[0.149]  
3,78  
[0.149]  
8
www.honeywell.com/sensing  
Figure 6. SIP Package Dimensional Drawings (For reference only: mm [in])  
SIP NN: No ports  
SIP AA: Dual axial barbed ports, opposite sides  
10,0  
10,0  
22,06  
4,87  
[0.192]  
[0.39]  
[0.39]  
[0.869]  
10,0  
[0.39]  
PORT 1  
PORT 2  
10,0  
[0.39]  
PORT 2  
PORT 1  
2X 4.93 DIA.  
[0.194]  
15,2  
[0.60]  
15,2  
[0.60]  
1
2
3
4
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
0,25  
[0.010]  
4X 0,51  
[0.020]  
4X 0,51  
[0.020]  
2,54 TYP.  
[0.100]  
SIP AN: Single axial barbed port  
SIP LN: Single barbless port  
10,0  
13,75  
13,75  
10,0  
[0.39]  
[0.541]  
[0.541]  
[0.39]  
10,0  
[0.39]  
PORT 2  
10,0  
[0.39]  
PORT 1  
PORT 2  
PORT 1  
4.93 DIA.  
[0.194]  
2,47 DIA.  
[0.097]  
15,2  
[0.60]  
15,2  
[0.60]  
1
2
3
4
1
2
3
4
0,25  
[0.010]  
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
SIP FF: Fastener mount, dual axial barbed ports, opposite sides  
29,48  
[1.161]  
27,20  
[1.071]  
23,12  
[0.910]  
10,44  
[0.411]  
17,78  
[0.700]  
PORT 2  
PORT 1  
2X 3.94 DIA.  
[0.155]  
2X 4,78 DIA.  
[0.188]  
20,16  
[0.794]  
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[.020]  
SIP FN: Fastener mount, single axial barbed port  
29,48  
[1.161]  
16,38  
[0.645]  
23,12  
[0.910]  
17,78  
[0.700]  
PORT 2  
PORT 1  
2X 3.94 DIA.  
[0.155]  
4.78 DIA.  
[0.188]  
20,16  
[0.794]  
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
Honeywell Sensing and Control  
9
Figure 6. SIP Package Dimensional Drawings (continued)  
SIP GN: Ribbed fastener mount, single axial barbed port  
27,96  
[1.101]  
21,60  
[0.850]  
16,51  
[0.650]  
19,06  
[0.750]  
PORT 2  
PORT 1  
2X 3,94 DIA.  
[0.155]  
4.78 DIA.  
[0.188]  
10,63  
[0.418]  
1
2
3 4  
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
SIP NB: Fastener mount, dual axial ports, same side  
27,31  
[1.075]  
25,3  
[0.996]  
21,60  
[0.850]  
2X 4,80 DIA.  
[0.189]  
PORT 2  
PORT 1  
22,87  
[0.900]  
2X 3.50 DIA.  
[0.138]  
13  
[0.52]  
4
3
2
1
0,25  
[0.010]  
4X 0,51  
[0.020]  
2,54 TYP.  
[0.100]  
SIP RN: Single radial barbed port  
10,0  
[0.39]  
5,80  
[0.228]  
PORT 1  
10,0  
[0.39]  
PORT 2  
1,92 DIA.  
[0.076]  
15,2  
[0.60]  
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
SIP RR: Dual radial barbed ports, same side  
10,0  
[0.39]  
6,16  
[0.243]  
PORT 1  
10,0  
[0.39]  
PORT 2  
2X 1,92 DIA.  
[0.076]  
15,2  
[0.60]  
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
10  
www.honeywell.com/sensing  
Figure 6. SIP Package Dimensional Drawings (continued)  
SIP DR: Dual radial barbed ports, opposite side  
SIP HH: Fastener mount, dual radial barbed ports, same side  
29,62  
10,58  
15,8  
[1.166]  
[0.416]  
[0.62]  
23,12  
[0.910]  
6,64  
[0.261]  
10,0  
[0.39]  
6,16  
[0.243]  
PORT 2  
PORT 1  
PORT 2  
10,0  
[0.39]  
PORT 1  
PORT 1  
PORT 2  
28,96  
[1.140]  
2X 4.93 DIA.  
[0.194]  
15,2  
[0.60]  
1
2
3
4
11,27  
[0.444]  
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
1
2
3 4  
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
SIP HN: Fastener mount, single radial barbed port  
SIP MN: Manifold mount, outer diameter seal  
23,12  
5,36  
[0.910]  
7,97  
[0.211]  
PORT 2  
PORT 1  
[0.314]  
4,78 DIA.  
[0.188]  
15,24 DIA.  
[0.600]  
PORT 1  
28,96  
[1.140]  
PORT 2  
12,5  
[0.49]  
2X 3,94 DIA.  
[0.155]  
1
2
3
4
0,25  
[0.010]  
11,27  
[0.444]  
4X 0,51  
[0.020]  
2,54 TYP.  
[0.100]  
1
2
3
4
0,25  
[0.010]  
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
SIP SN: Manifold mount, inner diameter seal  
PORT 2  
5,1  
[0.20]  
12,57  
[0.495]  
PORT 1  
13,11  
[0.516]  
15,6  
[0.61]  
1
2
3
4
2,54 TYP.  
[0.100]  
4X 0,51  
[0.020]  
Honeywell Sensing and Control  
11  
WARNING  
WARNING  
PERSONAL INJURY  
MISUSE OF DOCUMENTATION  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
The information presented in this product sheet is for  
reference only. DO NOT USE this document as a  
product installation guide.  
Failure to comply with these instructions could result  
in death or serious injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
Asia Pacific  
Europe  
+65 6355-2828; +65 6445-3033 Fax  
+44 (0) 1698 481481; +44 (0) 1698 481676 Fax  
+1-305-805-8188; +1-305-883-8257 Fax  
+1-800-537-6945; +1-815-235-6847  
+1-815-235-6545 Fax  
Latin America  
USA/Canada  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008213-2-EN IL50 GLO Printed in USA  
March 2011  
© 2011 Honeywell International Inc.  
Golden Valley, MN 55422  
www.honeywell.com  

相关型号:

SSCSANN060MDAA5

Peizoresistive Sensor, Differential, -.87Psi Min, 0.87Psi Max, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL

SSCSANN060MDAB5

Peizoresistive Sensor, Differential, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, SIP-4
HONEYWELL

SSCSANN060MDAC5

Peizoresistive Sensor, Differential, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, SIP-4
HONEYWELL

SSCSANN060MG2A3

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG2A5

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG3A3

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG3A5

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG4A3

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG4A5

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG5A3

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG5A5

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL

SSCSANN060MG6A3

TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,Digital output,SIP,60 mbar to 10 bar
HONEYWELL