These sensors measure absolute, differential, and gage
pressures. The absolute versions have an internal vacuum
reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
DESCRIPTION
The TruStability Standard Accuracy Silicon Ceramic (SSC)
Series is a piezoresistive silicon pressure sensor offering a
digital output for reading pressure over the specified full scale
pressure span and temperature range.
The SSC Series is fully calibrated and temperature
compensated for sensor offset, sensitivity, temperature effects,
and non-linearity using an on-board Application Specific
Integrated Circuit (ASIC). Calibrated output values for pressure
are updated at approximately 2 kHz.
The TruStability® pressure sensors are intended for use with
non-corrosive, non-ionic gases, such as air and other dry
gases. An available option extends the performance of these
sensors to non-corrosive, non-ionic liquids.
The SSC Series is calibrated over the temperature range of
-20 C to 85 C [-4 F to 185 F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
All products are designed and manufactured according to ISO
9001 standards.
FEATURES
Industry-leading long-term stability
Extremely tight accuracy of 0.25% FSS BFSL (Full Scale
Span Best Fit Straight Line)
Precision ASIC conditioning and temperature compensated
over -20 C to 85 C [-4 F to 185 F] temperature range
RoHS compliant
Total error band of 2% full scale span maximum
Modular and flexible design offers customers a variety of
package styles and options, all with the same industry-
leading performance specifications
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package
Low operating voltage
Virtually insensitive to mounting orientation
Internal diagnostic functions increase system reliability
Also available with analog output
Absolute, differential, and gage types
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
Custom calibration available
Extremely low power consumption
Various pressure port options
Liquid media option
I2C- or SPI- compatible 14-bit digital output (min. 12-bit
sensor resolution)
POTENTIAL APPLICATIONS
Medical:
Industrial:
-
-
-
-
-
-
-
-
-
-
-
Airflow monitors
-
-
-
-
-
-
-
Barometry
Anesthesia machines
Blood analysis machines
Gas chromatography
Gas flow instrumentation
Kidney dialysis machines
Oxygen concentrators
Pneumatic controls
Respiratory machines
Sleep apnea equipment
Ventilators
Flow calibrators
Gas chromatography
Gas flow instrumentation
HVAC
Life sciences
Pneumatic controls
Table 1. Absolute Maximum Ratings1
Parameter
Min.
-0.3
-0.3
Max.
6.0
Unit
Vdc
V
Supply voltage (Vsupply)
Voltage on any pin
Digital interface clock frequency:
I2C
Vsupply + 0.3
100
50
400
800
kHz
SPI
ESD susceptibility (human body model)
Storage temperature
Soldering time and temperature:
Lead solder (SIP, DIP)
Peak reflow (SMT)
3
kV
-40 [-40]
85 [185]
C [ F]
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Table 2. Operating Specifications
Parameter
Min.
Typ.
Max.
Unit
Supply voltage (Vsupply)2:
3.3 Vdc
3.0
4.75
3.33
5.03
3.6
5.25
Vdc
5.0 Vdc
Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.
Supply current:
3.3 Vdc supply
5.0 Vdc supply
1.6
2
2.1
3
mA
-
Compensated temperature range4
Operating temperature range5
Startup time (power up to data ready)
Response time
-20 [-4]
-40 [-40]
85 [185]
85 [185]
7.3
C [ F]
C [ F]
ms
2.8
0.46
ms
I2C voltage level low
I2C voltage level high
Pull up on SDA and SCL
Accuracy6
-
0.8
1
-
-
-
0.2
Vsupply
Vsupply
kOhm
%FSS BFSL
%FSS8
bits
-
-
0.25
2
Total error band7
Output resolution
12
2
www.honeywell.com/sensing
Table 3. Environmental Specifications
Parameter
Characteristic
Humidity:
Dry gases only (See “Options N and D” in Figure 1.)
Liquid media (See “Options T and V” in Figure 1.)
0% to 95% RH, non-condensing
100% condensing or direct liquid media on Port 1
MIL-STD-202F, Curve AK (20.7 g random)
MIL-STD-202F, Method 213B, Condition F
1 million cycles minimum
Vibration
Shock
Life9
Solder reflow
J-STD-020-C
Table 4. Wetted Materials10
Parameter
Covers
Port 1 (Pressure Port)
high temperature polyamide
alumina ceramic
Port 2 (Reference Port)
high temperature polyamide
alumina ceramic
Substrate
Adhesives
epoxy, silicone
epoxy, silicone
Electronic components
Notes:
ceramic, glass, solder, silicon
silicon, glass, gold, solder
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.
2. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved
within the specified operating voltage for each option.
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within
the specified performance limits.
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not
remain within the specified performance limits.
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal
effect on span, and thermal hysteresis.
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
the pressure range. (See Figure 1 for ranges.)
9. Life may vary depending on specific application in which sensor is utilized.
10. Contact Honeywell Customer Service for detailed material information.
CAUTION
PRODUCT DAMAGE
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.
Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate
inside the sensor, causing damage or affecting sensor output.
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to
enter and settle within the pressure sensor if it is in this position.
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a
dead-ended sensor is difficult and has limited effectiveness for removing residue.
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and
may lead to sensor failure.
Failure to comply with these instructions may result in product damage.
Honeywell Sensing and Control
3
Figure 1. Nomenclature and Order Guide
_
_ _ _ _ _ _ _ _
_
_
A
SSC
Supply Voltage
3 = 3.3 Vdc
Series
5 = 5.0 Vdc
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Transfer Function11
A = 10% to 90% of Vsupply
Output Type12
S = SPI (not available in SIP package)
2 = I2C, Address 0x28
3 = I2C, Address 0x38
4 = I2C, Address 0x48
5 = I2C, Address 0x58
6 = I2C, Address 0x68
7 = I2C, Address 0x78
Pressure Port (* indicates not available)
SMT
DIP
SIP
NN = No ports
NN = No ports
NN = No ports
Pressure Range13, 14
AA = Dual axial
barbed ports,
opposite sides
*
*
1 psi to 150 psi
60 mbar to 10 bar
Absolute
AN = Single
axial barbed
port
AN = Single
axial barbed
port
AN = Single
axial barbed
port
015PA = 0 psi to 15 psi
030PA = 0 psi to 30 psi
060PA = 0 psi to 60 psi
100PA = 0 psi to 100 psi
150PA = 0 psi to 150 psi
Absolute
001BA = 0 bar to 1 bar
1.6BA = 0 bar to 1.6 bar
2.5BA = 0 bar to 2.5 bar
004BA = 0 bar to 4 bar
006BA = 0 bar to 6 bar
010BA = 0 bar to 10 bar
LN = Single
axial barbless
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
Differential
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
060PD = ±60 psi
FF = Fastener
mount, dual axial
barbed ports,
opposite sides
Differential
060MD = ±60 mbar
100MD = ±100 mbar
160MD = ±160 mbar
250MD = ±250 mbar
400MD = ±400 mbar
600MD = ±600 mbar
001BD = ±1 bar
*
*
FN = Fastener
mount, single axial
barbed port
Gage
001PG = 0 psi to 1 psi
005PG = 0 psi to 5 psi
015PG = 0 psi to 15 psi
030PG = 0 psi to 30 psi
060PG = 0 psi to 60 psi
100PG = 0 psi to 100 psi
150PG = 0 psi to 150 psi
*
*
*
*
*
1.6BD = ±1.6 bar
2.5BD = ±2.5 bar
004BD = ±4 bar
GN = Ribbed
fastener mount,
single axial
barbed port
Gage
NB = Fastener
mount, dual axial
ports, same side
060MG = 0 mbar to 60 mbar
100MG = 0 mbar to 100 mbar
160MG = 0 mbar to 160 mbar
250MG = 0 mbar to 250 mbar
400MG = 0 bar to 400 mbar
600MG = 0 bar to 600 mbar
001BG = 0 bar to 1 bar
1.6BG = 0 bar to 1.6 bar
2.5BG = 0 bar to 2.5 bar
004BG = 0 bar to 4 bar
006BG = 0 bar to 6 bar
010BG = 0 bar to 10 bar
*
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
DR =Dual radial
barbed ports,
opposite sides
DR = Dual radial
barbed ports,
opposite sides
Options15
N = Dry gases only, no special options
D = Dry gases only, diagnostics on
T = Liquid media on port 1, no diagnostics
V = Liquid media on port 1, diagnostics on
HH = Fastener
mount, dual
radial barbed
ports, same side
*
*
*
*
HN = Fastener
mount, single
radial barbed
port
MN = Manifold
mount, outer
diameter seal
*
*
*
*
SN = Manifold
mount, inner
diameter seal
Notes:
11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and
Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other
transfer functions are available. Contact Honeywell Customer Service for more information.
12. Analog output is also available. Contact Honeywell Customer Service for more information.
13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information.
14. See Table 5 for an explanation of sensor pressure types.
15. See CAUTION on previous page.
4
www.honeywell.com/sensing
Figure 2. Transfer Function Limits
Figure 3. Completed Catalog Listing Example
SSCSANN100PGSA3
SIP package, AN pressure
port, no diagnostics, 100
psi gage, SPI output, 10%
to 90% calibration at
3.3 Vdc.
Table 5. Pressure Types
Pressure Type
Description
Output is proportional to the difference between applied pressure and a built-in reference to vacuum.
Pmin. is set at absolute zero pressure (full vacuum).
Absolute
Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2)
50% point of transfer function set at Port 1 = Port 2.
Output is proportional to the difference between applied pressure and atmospheric (ambient)
pressure. Pmin. is set at atmospheric pressure.
Differential
Gage
Table 6. Sensor Output at Significant Percentages
% Output
Digital Counts (decimal)
Digital Counts (hex)
0x0000
0
0
10
50
90
100
1638
8192
14746
16383
0x0666
0x2000
0x399A
0x3FFF
Table 7. Pressure Range Specifications for 1 psi to 150 psi
Long-term
Stability
(1000 hr,
Pressure Range
Order Code
Over-
Burst
Common Mode
Pressure18
pressure16
Pressure17
Pmin.
Pmax.
25 °C [77 °F])
Absolute
30 psi
60 psi
120 psi
250 psi
250 psi
Differential
10 psi
30 psi
30 psi
60 psi
120 psi
Gage
0 psi
0 psi
0 psi
0 psi
0 psi
15 psi
30 psi
60 psi
100 psi
150 psi
60 psi
120 psi
240 psi
250 psi
250 psi
NA
NA
NA
NA
NA
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
015PA
030PA
060PA
100PA
150PA
-1 psi
-5 psi
-15 psi
-30 psi
-60 psi
1 psi
5 psi
15 psi
30 psi
60 psi
10 psi
40 psi
60 psi
120 psi
240 psi
150 psi
150 psi
150 psi
150 psi
250 psi
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
001PD
005PD
015PD
030PD
060PD
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
0 psi
1 psi
5 psi
10 psi
30 psi
30 psi
60 psi
120 psi
250 psi
250 psi
10 psi
40 psi
60 psi
120 psi
240 psi
250 psi
250 psi
150 psi
150 psi
150 psi
150 psi
250 psi
250 psi
250 psi
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
001PG
005PG
015PG
030PG
060PG
100PG
150PG
15 psi
30 psi
60 psi
100 psi
150 psi
Honeywell Sensing and Control
5
Table 8. Pressure Range Specifications for 60 mbar to 10 bar
Pressure Range
Long-term
Stability
(1000 hr,
Over-
Burst
Common Mode
Pressure18
Order Code
pressure16
Pressure17
Pmin.
Pmax.
25 C [77 F])
Absolute
2 bar
4 bar
6 bar
8 bar
17 bar
17 bar
Differential
500 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
2 bar
0 bar
0 bar
0 bar
0 bar
0 bar
0 bar
1 bar
1.6 bar
2.5 bar
4 bar
6 bar
10 bar
4 bar
8 bar
8 bar
16 bar
17 bar
17 bar
NA
NA
NA
NA
NA
NA
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
001BA
1.6BA
2.5BA
004BA
006BA
010BA
-60 mbar
-100 mbar
-160 mbar
-250 mbar
-400 mbar
-600 mbar
-1 bar
-1.6 bar
-2.5 bar
-4 bar
60 mbar
100 mbar
160 mbar
250 mbar
400 mbar
600 mbar
1 bar
1.6 bar
2.5 bar
4 bar
700 mbar
700 mbar
700 mbar
2.5 bar
2.5 bar
4 bar
4 bar
8 bar
8 bar
16 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
060MD
100MD
160MD
250MD
400MD
600MD
001BD
1.6BD
2 bar
4 bar
6 bar
8 bar
2.5BD
004BD
Gage
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
0 bar
0 bar
0 bar
0 bar
0 bar
60 mbar
100 mbar
160 mbar
250 mbar
400 mbar
600 mbar
1 bar
1.6 bar
2.5 bar
4 bar
500 mbar
500 mbar
500 mbar
1.4 bar
1.4 bar
2 bar
2 bar
4 bar
6 bar
8 bar
700 mbar
700 mbar
700 mbar
2.5 bar
2.5 bar
4 bar
4 bar
8 bar
8 bar
3.5 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
16 bar
17 bar
17 bar
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.35% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
0.25% FSS
060MG
100MG
160MG
250MG
400MG
600MG
001BG
1.6BG
2.5BG
004BG
006BG
010BG
16 bar
17 bar
17 bar
6 bar
10 bar
17 bar
17 bar
0 bar
Notes:
16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to
the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this
applies to all available pressure ports at any temperature with the operating temperature range.
17. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product
should not be expected to function after exposure to any pressure beyond the burst pressure.
18. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without
causing changes in specified performance.
Table 9. Pinout for SMT and DIP Packages
Output Type
Pin 1
GND
GND
Pin 2
Vsupply
Vsupply
Pin 3
SDA
Pin 4
SCL
Pin 5
NC
Pin 6
NC
Pin 7
NC
Pin 8
NC
I2C
SPI
MISO
SCLK
SS
NC
NC
NC
Table 10. Pinout for SIP Package
Output Type
Pin 1
Pin 2
Pin 3
Pin 4
I2C
GND
Vsupply
SDA
SCL
6
www.honeywell.com/sensing
Figure 4. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])
DIP NN: No ports
DIP AN: Single axial barbed port
13,75
0,25
[0.010]
0,25
10,0
[0.39]
[0.541]
5,44
[0.214]
[0.010]
10,0
[0.39]
8
7
6
5
8
7
6
5
7,95
[0.313]
6,2
[0.24]
13,35
[0.525]
13,35
[0.525]
6,99
[0.275]
6,99
[0.275]
4,93 DIA.
[0.194]
PORT 2
PORT 1
PORT 2
PORT 1
1
2
3
4
1
2
3
4
9,24
[0.364]
11,21
[0.441]
9,24
[0.364]
10,85
[0.427]
2,54 TYP.
[0.100]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP LN: Single axial barbless port
DIP RN: Single radial barbed port
5,80
0,25
0,25
[0.010]
[0.228]
[0.010]
5,80
[0.228]
10,0
[0.39]
10,0
[0.39]
8
7
6
5
8
7
6
5
2,47 DIA.
[0.097]
4,2
[0.17]
13,35
[0.525]
13,35
[0.525]
6,99
[0.275]
6,99
[0.275]
PORT 1
PORT 2
PORT 2
PORT 1
1,93 DIA.
[0.076]
1
2
3
4
1
2
3
4
9,24
[0.364]
9,24
[0.364]
2,54 TYP.
[0.100]
2,54 TYP.
[0.100]
11,21
[0.441]
11,21
[0.441]
13,75
[0.541]
6,95
[0.274]
1,00
[0.039]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP RR: Dual radial barbed ports, same side
DIP DR: Dual radial barbed ports, opposite sides
,25
0,25
15,76
[0.620]
10,0
[0.39]
6,16
[0.242]
6,16
[0.242]
[0.010]
[0.010]
10,0
[0.39]
4,0
[0.16]
8
7
6
5
2X 1,93 DIA.
[0.076]
2X 1,93 DIA.
[0.076]
8
7
6
5
13,35
PORT 1
PORT 2
13,35
[0.525]
[0.525]
6,99
[0.275]
6,99
PORT 2
[0.275]
PORT 1
PORT 1
PORT 2
4,65
[0.183]
PORT 1
PORT 2
1
2
3
4
9,24
[0.364]
9,24
[0.364]
2,54 TYP.
[0.100]
1
2
3
4
11,21
[0.441]
2,54 TYP.
[0.100]
11,21
[0.441]
3,78
[0.149]
3,78
[0.149]
8X 0,46
[0.018]
8X 0,46
[0.018]
Honeywell Sensing and Control
7
Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])
SMT NN: No ports SMT AN: Single axial barbed port
10,0
[0.39]
13,75
[0.541]
5,44
[0.214]
10,0
[0.39]
8
7
6
5
8
7
6
5
7,95
[0.313]
13,4
[0.53]
6,99
[0.275]
PORT 1
PORT 2
13,4
[0.53]
4,93 DIA.
[0.194]
6,99
[0.275]
PORT 2
PORT 1
1
2
3
4
8X 0,46
[0.018]
4,80
2,54 TYP.
[0.100]
1
2
3
4
[0.189]
4,80
[0.189]
8X 0,46
[0.018]
6,41
[0.252]
2,54 TYP.
[0.100]
6,77
[0.266]
SMT LN: Single axial barbless port
SMT RN: Single radial barbed port
5,80
[0.228]
5,80
[0.228]
10,0
[0.39]
10,0
[0.394]
8
7
6
5
8
7
6
5
4,2
[0.17]
2,47 DIA.
[0.097]
13,3
[0.53]
13,35
[0.525]
6,99
[0.275]
6,99
[0.275]
PORT 1
PORT 1
PORT 2
PORT 2
1,93 DIA.
[0.076]
PORT 1
1
2
3
4
4,80
8X 0,46
[0.018]
1
2
3
4
4,80
8X 0,46
[0.018]
2,54 TYP.
[0.100]
[0.189]
2,54 TYP.
[0.100]
[0.189]
6,77
[0.266]
6,77
[0.266]
13,75
[0.541]
SMT RR: Dual radial barbed ports, same side
SMT DR: Dual radial barbed ports, opposite sides
10,0
[0.39]
15,8
6,16
[0.242]
[0.62]
4,0
[0.16]
10,0
[0.39]
6,16
[0.242]
8
7
6
5
2X 2,93
[0.115]
2X 1,93 DIA.
[0.076]
8
7
6
5
13,35
[0.525]
PORT 1
PORT 2
6,99
[0.275]
13,4
[0.53]
PORT 1
PORT 2
2X 1,93 DIA.
[0.076]
6,99
[0.275]
4,6
[0.18]
PORT 2
PORT 1
1
2
3
4
4,80
8X 0,46
[0.018]
1
2
3
4
2,54 TYP.
[0.100]
[0.189]
4,80
8X 0,46
[0.018]
2,54 TYP.
[0.100]
[0.189]
6,77
[0.266]
6,77
[0.266]
3,78
[0.149]
3,78
[0.149]
8
www.honeywell.com/sensing
Figure 6. SIP Package Dimensional Drawings (For reference only: mm [in])
SIP NN: No ports
SIP AA: Dual axial barbed ports, opposite sides
10,0
10,0
22,06
4,87
[0.192]
[0.39]
[0.39]
[0.869]
10,0
[0.39]
PORT 1
PORT 2
10,0
[0.39]
PORT 2
PORT 1
2X 4.93 DIA.
[0.194]
15,2
[0.60]
15,2
[0.60]
1
2
3
4
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
0,25
[0.010]
4X 0,51
[0.020]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
SIP AN: Single axial barbed port
SIP LN: Single barbless port
10,0
13,75
13,75
10,0
[0.39]
[0.541]
[0.541]
[0.39]
10,0
[0.39]
PORT 2
10,0
[0.39]
PORT 1
PORT 2
PORT 1
4.93 DIA.
[0.194]
2,47 DIA.
[0.097]
15,2
[0.60]
15,2
[0.60]
1
2
3
4
1
2
3
4
0,25
[0.010]
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP FF: Fastener mount, dual axial barbed ports, opposite sides
29,48
[1.161]
27,20
[1.071]
23,12
[0.910]
10,44
[0.411]
17,78
[0.700]
PORT 2
PORT 1
2X 3.94 DIA.
[0.155]
2X 4,78 DIA.
[0.188]
20,16
[0.794]
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[.020]
SIP FN: Fastener mount, single axial barbed port
29,48
[1.161]
16,38
[0.645]
23,12
[0.910]
17,78
[0.700]
PORT 2
PORT 1
2X 3.94 DIA.
[0.155]
4.78 DIA.
[0.188]
20,16
[0.794]
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
Honeywell Sensing and Control
9
Figure 6. SIP Package Dimensional Drawings (continued)
SIP GN: Ribbed fastener mount, single axial barbed port
27,96
[1.101]
21,60
[0.850]
16,51
[0.650]
19,06
[0.750]
PORT 2
PORT 1
2X 3,94 DIA.
[0.155]
4.78 DIA.
[0.188]
10,63
[0.418]
1
2
3 4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP NB: Fastener mount, dual axial ports, same side
27,31
[1.075]
25,3
[0.996]
21,60
[0.850]
2X 4,80 DIA.
[0.189]
PORT 2
PORT 1
22,87
[0.900]
2X 3.50 DIA.
[0.138]
13
[0.52]
4
3
2
1
0,25
[0.010]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
SIP RN: Single radial barbed port
10,0
[0.39]
5,80
[0.228]
PORT 1
10,0
[0.39]
PORT 2
1,92 DIA.
[0.076]
15,2
[0.60]
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP RR: Dual radial barbed ports, same side
10,0
[0.39]
6,16
[0.243]
PORT 1
10,0
[0.39]
PORT 2
2X 1,92 DIA.
[0.076]
15,2
[0.60]
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
10
www.honeywell.com/sensing
Figure 6. SIP Package Dimensional Drawings (continued)
SIP DR: Dual radial barbed ports, opposite side
SIP HH: Fastener mount, dual radial barbed ports, same side
29,62
10,58
15,8
[1.166]
[0.416]
[0.62]
23,12
[0.910]
6,64
[0.261]
10,0
[0.39]
6,16
[0.243]
PORT 2
PORT 1
PORT 2
10,0
[0.39]
PORT 1
PORT 1
PORT 2
28,96
[1.140]
2X 4.93 DIA.
[0.194]
15,2
[0.60]
1
2
3
4
11,27
[0.444]
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
1
2
3 4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP HN: Fastener mount, single radial barbed port
SIP MN: Manifold mount, outer diameter seal
23,12
5,36
[0.910]
7,97
[0.211]
PORT 2
PORT 1
[0.314]
4,78 DIA.
[0.188]
15,24 DIA.
[0.600]
PORT 1
28,96
[1.140]
PORT 2
12,5
[0.49]
2X 3,94 DIA.
[0.155]
1
2
3
4
0,25
[0.010]
11,27
[0.444]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
1
2
3
4
0,25
[0.010]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP SN: Manifold mount, inner diameter seal
PORT 2
5,1
[0.20]
12,57
[0.495]
PORT 1
13,11
[0.516]
15,6
[0.61]
1
2
3
4
2,54 TYP.
[0.100]
4X 0,51
[0.020]
Honeywell Sensing and Control
11
WARNING
WARNING
PERSONAL INJURY
MISUSE OF DOCUMENTATION
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Failure to comply with these instructions could result
in death or serious injury.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Asia Pacific
Europe
+65 6355-2828; +65 6445-3033 Fax
+44 (0) 1698 481481; +44 (0) 1698 481676 Fax
+1-305-805-8188; +1-305-883-8257 Fax
+1-800-537-6945; +1-815-235-6847
+1-815-235-6545 Fax
Latin America
USA/Canada
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
008213-2-EN IL50 GLO Printed in USA
March 2011
© 2011 Honeywell International Inc.
Golden Valley, MN 55422
www.honeywell.com
相关型号:
SSCSRRN030PG4A5
Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN030PG5A5
Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN030PG6A5
Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN030PG7A3
Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MD2A3
Peizoresistive Sensor, Differential, -.58Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MD3A3
Peizoresistive Sensor, Differential, -.58Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MD4A5
Peizoresistive Sensor, Differential, -.58Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MD5A3
Peizoresistive Sensor, Differential, -.58Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MDAA5
Peizoresistive Sensor, Differential, -.58Psi Min, 0.58Psi Max, 0.25%, Rectangular, Through Hole Mount, ROHS COMPLIANT, SIP-4
HONEYWELL
SSCSRRN040MG3A5
Peizoresistive Sensor, Gage, 0Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MG4A3
Peizoresistive Sensor, Gage, 0Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
SSCSRRN040MG7A3
Peizoresistive Sensor, Gage, 0Psi Min, 0.58Psi Max, 0.25%, 0.20-0.80V, Rectangular, Through Hole Mount, ROHS COMPLIANT, CERAMIC, SIP-4
HONEYWELL
©2020 ICPDF网 联系我们和版权申明