Microstructure Pressure Sensors  
0 psi to 1 psi through  
0 psi to 150 psi  
The SX SMT Series provides a most cost-effective method of  
measuring absolute and gage pressures in a fully packaged  
sensor. These sensors are designed primarily for use with  
clean, dry gases such as air and nitrogen.  
ported device offers a tube attachment port that is particularly  
useful in gage applications.  
The 4-pin closed bridge configuration allows electrical  
connection with additional pads provided for mechanical  
support. Pulsed power is recommended to achieve maximum  
accuracy and conserve battery power in portable applications.  
This series features the standard SX chip in a ceramic, surface  
mount package. The standard version features a low profile  
plastic lid to better withstand high temperatures. The optional  
FEATURES  
POTENTIAL APPLICATIONS  
Low cost  
Pneumatic controls  
Small size  
Automotive diagnostics  
Medical equipment/ instrumentation  
Dental equipment  
Absolute or gage pressures  
High-impedance bridge  
Low power consumption  
Environmental controls  
Barometric pressure measurement  
Altimeters  
Pneumatic controls  
Battery powered equipment  
SX SMT Series  
SPECIFICATIONS(1)  
Characteristic  
Maximum Rating  
Supply voltage  
12 Vdc  
Operating temperature  
Storage temperature  
Lead temperature (soldering 2 s to 4 s)  
-40 °C to 125 °C [-40 °F to 257 °F]  
-55 °C to 125 °C [-67 °F to 257 °F]  
250 °C [482 °F]  
STANDARD PRESSURE RANGES FOR SX SERIES(1)  
Maximum Pressure (2)  
Operating Pressure  
Sensitivity (3)  
Unit  
Nominal  
Std. Dev.  
0.40  
0 psi to 1 psi  
0 psi to 5 psi  
0 psi to 15 psi  
0 psi to 30 psi  
0 psi to 100 psi  
0 psi to 150 psi  
20 psi  
20 psi  
30 psi  
60 psi  
150 psi  
200 psi  
3.90  
2.70  
1.50  
0.66  
0.30  
0.14  
mV/V/psi  
mV/V/psi  
mV/V/psi  
mV/V/psi  
mV/V/psi  
mV/V/psi  
0.38  
0.25  
0.06  
0.05  
0.02  
PERFORMANCE SPECIFICATIONS(1)  
Characteristic  
Min.  
-2400  
-35.0  
Typ.  
-2150  
-20.0  
4
0.2  
0.1  
100  
4.1  
750  
4.1  
Max.  
-1900  
0
0.5  
810  
Unit  
ppm/°C  
mV  
µV/V/°C  
% FS  
mV  
µs  
kΩ  
ppm/°C  
kΩ  
Temperature coefficient of span(4,5)  
Zero pressure offset TA  
Temperature coefficient of offset(6,5)  
Combined, linearity and hysteresis(7)  
Long term stability of offset and sensitivity(8)  
Response time (10% to 90%)(9)  
Input resistance TA = 25 °C [77 °F]  
Temperature coefficient of resistance(4,5)  
Output impedance  
Repeatability (10)  
0.5  
% FSS  
Notes:  
1. Reference Conditions: Supply voltage, Vs = 5.0 Vdc, TA = 0 °C to 70 °C [32 °F to 158 °F], common-mode line pressure =  
0 psig, pressure applied to P1 unless otherwise noted.  
2. If maximum pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may  
fracture.  
3. Sensitivity is the ratio of the output signal voltage change to the corresponding input pressure change. The sensitivity is  
characterized by design and periodic production testing. This parameter in not 100 % tested in production.  
4. This is the best straight line fit for operation between 0 °C to 70 °C [32 °F to 158 °F]. For operation outside this temperature,  
contact Honeywell representative for more specific application information.  
5. This parameter is not 100 % tested. It is guaranteed by process design and tested on a sample basis only. Temperature  
coefficient of span for the 1.0 psi and 5.0 psi devices is -2550 ppm/°C to -2050 ppm/°C.  
6. Slope of the best straight line fit for operation between 0 °C to 70 °C [32 °F to 158 °F]. For operation outside this temperature,  
contact factory for more specific application information.  
7. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing  
pressure.  
8. Long-term stability over a one year period.  
9. Response time for 0 psi to full scale span pressure step change.  
10. Difference in output at any pressure with the operating pressure range and temperature within 0 °C to 70 °C [32 °F to 158 °F]  
after 100 temperature cycles 0 °C to 70 °C [32 °F to 158 °F], 1.0 million pressure cycles 0 psi to full-scale span.  
2
www.honeywell.com/sensing  
Microstructure Pressure Sensors  
DIMENSIONAL DRAWINGS (For reference only. mm [in])  
LOW PROFILE SMT  
0,70  
7X 0,76 [.03]  
[.03]  
3,30  
[.13]  
3,70  
[.14]  
1,10  
[.05]  
0,5 [.02]  
FOR GAGE PORT (P2)  
O
O
8X 0,76 [.03]  
3,80  
[.15]  
+ OUT  
6,60  
[.26]  
7,60  
[.30]  
+ EX  
- EX  
3,30  
[.13]  
- OUT  
8X 1,27  
[.05]  
ON CENTER  
PADS  
6,60  
[.26]  
2,00  
[.08]  
3,30  
[.13]  
7,60  
[.30]  
PORTED “P” SMT  
0,76  
7X  
0,70  
[.03]  
3,3  
[.13]  
[.03]  
0,5 [.02]  
FOR GAGE PORT (P2)  
R0,3  
[.01]  
1,01  
[.04]  
0,76  
[.03]  
8X  
R0,3  
[.01]  
+ OUT  
3,3  
[.13]  
6,6  
[.26]  
7,61  
[.30]  
+ EX  
- EX  
6,6  
[.26]  
7,6  
[.30]  
3,8  
[.15]  
- OUT  
2,05  
±0.76  
2,0  
[.08]  
[0.081  
±0.003]  
8,7  
[.34]  
1,27  
3,3  
[.13]  
8X  
[.05] ON CENTER  
PADS  
PORTED “LP” SMT  
0,76  
7X  
0,70  
[.03]  
3,3  
[.13]  
[.03]  
0,5 [.02]  
FOR GAGE PORT (P2)  
R0,3  
[.01]  
1,01  
[.04]  
0,76  
[.03]  
8X  
R0,3  
[.01]  
+ OUT  
3,3  
[.13]  
6,6  
[.26]  
7,61  
[.30]  
+ EX  
- EX  
6,6  
[.26]  
7,6  
[.30]  
3,8  
[.15]  
2,3  
- OUT  
[.09]  
2,0  
[.08]  
8,7  
[.34]  
1,27  
3,3  
[.13]  
8X  
[.05] ON CENTER  
PADS  
EQUIVALENT CIRCUITS  
Vs  
- Out  
+Out  
Honeywell Sensing and Control  
3
SX SMT ORDER GUIDE  
XXX  
XXX  
X
XXXXX  
Cover Type  
Ceramic = SX  
Housing Style  
Plastic Cover = SXP  
Low profile cover = SMT  
Ported "P" = SMPT  
Ported "LP" = SMTLP  
Pressure Range  
0-1 = 01*  
0-5 = 05*  
0-15 = 15  
0-30 = 30  
0-100 = 100  
0-300 = 150  
Pressure Type  
Gage = G  
Absolute = A  
*Not available in absolute pressure types.  
WARNING  
MISUSE OF DOCUMENTATION  
WARNING  
PERSONAL INJURY  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
Failure to comply with these instructions could result in  
death or serious injury.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
E-mail: info.sc@honeywell.com  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
Asia Pacific +65 6355-2828  
+65 6445-3033 Fax  
Europe  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
Latin America +1-305-805-8188  
+1-305-883-8257 Fax  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
USA/Canada +1-800-537-6945  
+1-815-235-6847  
+1-815-235-6545 Fax  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008098-5-EN IL50 GLO Printed in USA  
April 2008  
© 2008 Honeywell International Inc.  
Minneapolis, MN 55422  
www.honeywell.com/sensing  

相关型号:

SX30DN

Pressure sensors
SENSORTECHNIC

SX30DN

Peizoresistive Sensor, Differential, 0Psi Min, 30Psi Max, -20-110mV, Through Hole Mount, N HOUSING PACKAGE, 4 PIN
HONEYWELL

SX30DP1

Peizoresistive Sensor, Differential, 0Psi Min, 30Psi Max, -20-110mV, Round, Through Hole Mount, NIPPLE PACK, 4 PIN
HONEYWELL

SX30GD2

Pressure sensors
SENSORTECHNIC

SX30GLP

Microstructure Pressure Sensors 0 psi to 1 psi through 0 psi to 150 psi
HONEYWELL

SX30GP

Microstructure Pressure Sensors 0 psi to 1 psi through 0 psi to 150 psi
HONEYWELL

SX30GSMPLT

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, Square, Surface Mount, CERAMIC, SMT, 8 PIN
HONEYWELL

SX30GSMPT

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, Square, Surface Mount, CERAMIC, SMT, 8 PIN
HONEYWELL

SX30GSMT

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, Square, Surface Mount, SMT-6
HONEYWELL

SX30GSMTLP

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, Surface Mount, CERAMIC, SMT-8
HONEYWELL

SX30GSMTP

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, Square, Surface Mount, SMT-6
HONEYWELL

SX30GSO

Peizoresistive Sensor, Gage, 0Psi Min, 30Psi Max, -20-110mV, Round, Through Hole Mount, TO-39, 5 PIN
HONEYWELL