SZR-MY2-1P-DC24V [HONEYWELL]

Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount;
SZR-MY2-1P-DC24V
型号: SZR-MY2-1P-DC24V
厂家: Honeywell    Honeywell
描述:

Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount

光电二极管 继电器
文件: 总10页 (文件大小:545K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose  
Power Relay  
SZR-MY Series  
FEATURES  
Small package design  
DPDT has a fine silver  
contact with 5 A capability  
4PDT has a gold-plated  
silver contact with 3 A  
capability  
High dielectric strength  
(1,800 Vac)  
High reliability and long life  
Ultra-high sensitivity with  
quick response time  
(20 ms max.)  
Options include LED  
indicator, diode protection,  
and LED indicator/diode  
protection  
UL listed, CE certified,  
CSA certified  
®
SZR-MY Series general-purpose power relays are designed for a wide  
range of applications including power as well as logic control for factory  
machines and control panels.  
SZR-MY Series relays have a small package design for multiple  
application needs. Relays are available in two configurations: DPDT with a  
5A load and 4PDT with a 3 A load.  
One standard and three options are available: LED indicator, internal  
surge protection diode, and LED indicator/diode protection. Honeywell’s  
global sales and distribution channels ensure a rapid response and excellent  
customer service.  
TYPICAL APPLICATIONS  
Control panels  
Elevator panels  
Machine tools  
Test equipment  
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet is for reference only. Do  
not use this document as a product installation guide.  
Complete installation, operation, and maintenance information is provided  
in the instructions supplied with each product.  
Failure to comply with these instructions could result in death or  
serious injury.  
WARNING  
PERSONAL INJURY  
DO NOT USE these  
products as safety or  
emergency stop devices or  
in any other application  
where failure of the product  
could result in personal  
injury.  
Failure to comply with  
these instructions could  
result in death or serious  
injury.  
Sensing and Control  
General Purpose  
Power Relays  
SZR-MY Series  
RELAY MODEL SELECTION GUIDE  
Type  
Catalog Listing  
Terminal  
Contact  
DPDT  
4PDT  
DPDT  
4PDT  
DPDT  
4PDT  
DPDT  
4PDT  
DPDT  
4PDT  
SZR-MY2-1  
SZR-MY4-1  
Standard  
Plug-in/Solder  
SZR-MY2-1P  
SZR-MY4-1P  
SZR-MY2-N1  
SZR-MY4-N1  
SZR-MY2-D1  
SZR-MY4-D1  
SZR-MY2-X1  
SZR-MY4-X1  
PCB  
LED Indicator  
Plug-in/Solder  
DIODE surge suppression  
LED indicator + surge suppression  
SOCKETS – REQUIRED ACCESSORIES  
Din-rail Mounting  
Solder Terminal  
PCB Terminal  
Relay Contact  
DPDT  
For use with  
SZR-MY2-1, -N1, -  
D1, -X1  
SZX-SMB-08P  
SZX-SMF-08N  
SZX-SMB-08  
4PDT  
For use with  
SZR-MY4-1, -N1, -  
D1, -X1  
SZX-SMB-14P  
SZX-SMF-14N  
SZX-SMB-14  
2
Honeywell Sensing and Control  
General Purpose  
Power Relays  
SZR-MY Series  
CONTACT RATINGS  
Type  
DPDT  
4PDT  
Load Resistive Load (p.f. = 1)  
Inductive load  
Resistive Load (p.f. = 1)  
Inductive load  
Ratings  
(p.f. = 0.4, L/R = 7 ms)  
(p.f. = 0.4, L/R = 7 ms)  
Rated load  
220 Vac, 5A  
24 Vdc, 5A  
220 Vac, 2A  
24 Vdc, 2A  
220 Vac, 3A  
24 Vdc, 3A  
220 Vac, 0.8 A  
24 Vdc, 1.5 A  
Carry current  
Max. operating  
voltage  
5A  
3A  
250 Vac, 125 Vdc  
250 Vac, 125 Vdc  
Max. operating  
current  
5 A  
3 A  
Max. switching  
capacity  
1,100 VA, 120 W  
440 VA, 48 W  
660 VA, 72 W  
176 VA, 16 W  
Min. permissible  
load  
1 mA, 5 Vdc  
1 mA, 1 Vdc  
COIL RATINGS  
Rated Current  
(mA)  
Coil Inductance (H)  
Armature Armature Pick-up Dropout Maximum  
Rated  
Voltage  
(V)  
50 Hz  
60 Hz  
Coil  
Power  
Consumption  
(W)  
resistance  
OFF  
ON  
Voltage Voltage  
Voltage  
(V)  
(V)  
(V)  
()  
12.2  
6
214.1  
106.5  
53.8  
183  
91  
0.04  
0.17  
0.69  
3.22  
14.54  
19.2  
54.75  
83.5  
0.17  
0.73  
3.2  
0.08  
0.33  
1.3  
Approx.  
1.0 W to 1.2 W  
(60 Hz)  
12  
24  
46  
46  
180  
Max.  
75 %  
Min.  
30%  
AC  
50  
25.7  
22  
788  
5.66  
24.6  
32.1  
94.07  
136.4  
0.33  
1.37  
5.72  
21.0  
86.2  
110%  
100/110 11.7/12.9 10/11  
110/120 9.9/10.8 8.4/9.2  
3,750  
4,430  
12,950  
18,790  
Approx  
0.9 W to 1.1 W  
(60 Hz)  
200/220  
220/240  
6
6.2/6.8  
4.8/5.3  
5.3/5.8  
4.2/4.6  
150  
40  
160  
12  
75  
Max.  
75%  
Min.  
10%  
Approx.  
0.9 W  
DC  
24  
36.9  
18.5  
650  
110%  
48  
2,600  
11,000  
10.6  
45.6  
100/110  
9.1/10  
Note 1: The rated current and coil resistance are measured at a coil temperature of 23 °C [73.4 °F] with tolerances of +15%,  
-20% for AC rated current and 15% for DC coil resistance.  
Note 2: The rated current of N1 and X1 types is 4 mA higher than the value in the table above.  
Honeywell Sensing and Control  
3
General Purpose  
Power Relays  
SZR-MY Series  
SPECIFICATIONS  
Contact material  
Contact resistance  
Operate time  
Silver  
Max. 50 MOhm  
Max. 20 ms  
Release time  
Max. 20 ms  
Operating  
frequency  
Mechanical  
Electrical  
18,000 operations per hour  
1,800 operations per hour  
Insulation resistance  
Min. 100 Mw at 500 Vdc  
Dielectric withstand voltage  
1,800 Vac 50 Hz/60 Hz for one minute between non-continuous current  
carrying terminals and between coil thermals and contact terminals  
10 Hz to 55 Hz at double amplitude of 1.0 mm  
Vibration  
resistance  
Mechanical durability  
Malfunction durability  
10 Hz to 55 Hz at double amplitude of 1.0 mm  
Shock resistance Mechanical durability  
Malfunction durability  
1,000 m/s2 (approx. 100 g)  
200 m/s2 (approx. 20 g)  
Service life  
Mechanical  
AC: Min. 50 million operations (at operating frequency of 18,000 operations/hour)  
DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour)  
DPDT: Min. 500,000 operations (at operating frequency of 1,800 operations/hour)  
4PDT: Min. 200,000 operations (at operating frequency of 1,800 operations/hour)  
Approximately 35 g  
Electrical  
Weight  
Note 1: The data shown above are of initial value  
CHARACTERISTIC DATA  
Max.  
Switchin  
g capac  
ity  
Resi  
stive Loa  
d
Ind  
uctive L  
oad  
AC resistive  
1,000  
500  
1,000  
500  
10  
5
AC110V  
AC220V  
AC110V p.f.=0.4  
AC220V p.f.=0.4  
DPDT  
AC inductive  
p.f.=0.4  
DC resistive  
100  
50  
100  
50  
1
0.5  
DC inductive  
L/R=7ms  
DC24V  
DC24V L/R=7ms  
1
10  
10  
0.1  
0
1
2
3
4
5
6
7
8
0
2
5
10  
50 100  
500  
Current(A)  
Rated operating voltage(V)  
Current(A)  
Ma  
x. Switc  
Resist  
Ind  
ive Load  
uctive L  
oad  
hing cap  
acity  
1,000  
500  
1,000  
500  
10  
5
4PDT  
AC resistive  
AC110V  
3
AC110V p.f.=0.4  
AC220V  
AC inductive  
p.f.=0.4  
DC30V L/R=7ms  
100  
50  
100  
50  
DC resistive  
1
0.5  
0.1  
DC inductive  
L/R=7ms  
AC220V p.f.=0.4  
DC30V  
10  
10  
0
0.5  
1
1.5  
Current(A)  
0
1
2
3
5
100  
10  
50  
500  
Current(A)  
Rated operating voltage(V)  
4
Honeywell Sensing and Control  
General Purpose  
Power Relays  
SZR-MY Series  
HOLDING CLIPS  
Holding clips are included with the sockets  
Holding clips for the SMF-08N and SMF-14N cannot be removed once inserted  
Holding clips for all SMB sockets are wire for easy removal  
Holding clips are to be inserted into the slots provided on the socket  
DIMENSIONS (For reference only – mm/in)  
Figure 1. Dimensions  
For SZX-SMF-08N and SZX-SMF-14N sockets  
Figure 2. Dimensions  
For all SZX-SMB sockets  
29,0 [1.14]  
6,5  
[0.26]  
5,0  
[0.20]  
14,5  
[0.57]  
4,6 [0.18]  
6,2  
[0.24]  
49,9 [1.96]  
Honeywell Sensing and Control  
5
General Purpose  
Power Relays  
SZR-MY Series  
CATALOG LISTING MATRIX  
SZR – MY 2 - ___ 1 P - AC110-120V  
Voltage Rating:  
AC6V  
=
=
=
=
=
6 Vac  
Terminal Type  
__ = Solder/Plug-in  
P = PCB  
AC12V  
AC24V  
AC50V  
AC100V  
12 Vac  
24 Vac  
50 Vac  
100 Vac  
Mounting Type  
1 = Terminal  
AC110-120V = 110/120 Vac  
AC200V  
AC220V  
AC220-240V = 220/240 Vac  
=
=
200 Vac  
220 Vac  
Option Type  
__ = No Indicator or Diode  
D = Internal Surge Protection Diode  
N = Red LED Operation Indicator  
X = LED and Diode  
Poles  
2 = DPDT  
4 = 4PDT  
DC6V  
=
=
=
=
=
6 Vdc  
DC12V  
DC24V  
DC48V  
DC100V  
12 Vdc  
24 Vdc  
48 Vdc  
100 Vdc  
Amp Rating:  
MY = 5 A or 3 A  
LY = 10 A  
Product Type  
General Purpose Relay  
6
Honeywell Sensing and Control  
General Purpose  
Power Relays  
SZR-MY Series  
FIGURE 3. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR  
SZR-MY2-1, SZR-MY2-N1, SZR-MY2-D1, and SZR-MY2-X1  
8 - O 1,2 [0.05] x 3 Holes  
0,5  
[0.02]  
Max. 21,5  
[0.85]  
Max. 36,0 [1.42]  
6,0  
[0.24]  
MY2-1  
MY2-N1 AC  
MY2-N1 DC  
MY2-D1  
MY2-X1  
1
5
4
8
1
4
8
1
5
4
8
1
5
4
8
1
5
4
8
5
9
12  
14  
9
12  
14  
9
12  
14  
9
12  
14  
9
12  
-
+
-
+
-
+
13  
13  
13  
13  
13  
14  
Bottom view  
FIGURE 4. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR  
SZR-MY2-1P and SZR-MY4-1P  
3,5  
[0.14]  
0,5  
[0.02]  
Max. 21,5  
[0.85]  
6,0  
Max. 36,0 [1.42]  
[0.24]  
The circuit diagram is the same wit standard type of SZR-MY2-1 or the SZR-MY4-1  
Honeywell Sensing and Control  
7
General Purpose  
Power Relays  
SZR-MY Series  
FIGURE 5. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR  
SZR-MY4-1, SZR-MY4-N1, SZR-MY4-D1, and SZR-MY4-X1  
14 - O 1.2 [0.05] x 3 Holes  
Max. 21,5  
[0.85]  
0,5  
[0.02]  
Max. 36,0 [1.42]  
6,0  
[0.24]  
MY4-1  
MY4-N1 AC  
MY4-N1 DC  
MY4-D1  
MY4-X1  
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
10 11  
12  
14  
10 11  
9
10 11 12  
14  
9
9
12  
14  
9
10 11 12  
9
10 11 12  
-
+
-
+
-
+
13  
13  
13  
13  
14  
13  
14  
-
-
Bottom view  
FIGURE 6. CIRCUIT DRAWING FOR SZR-MY2- and SZR-MY4-  
4PDT  
13.2  
DPDT  
13.2  
0.1  
14- 1.3  
4.4  
0.1  
3.75  
8- 1.3  
8
Honeywell Sensing and Control  
General Purpose  
Power Relays  
SZR-MY Series  
SOCKETS  
FIGURE 7. SZX-SMF-08N  
FIGURE 8. SZX-SMF-14N  
6,0  
[0.24]  
6,0  
[0.24]  
3,9  
[0.15]  
3,9  
[0.15]  
26,0  
[1.02]  
26,0  
[1.02]  
2-M3 or 2-M4  
2-M3 or 2-M4  
2 - O 4,5 [0.18] Holes  
2 - O 4,5 [0.18] Holes  
18,0  
[0.70]  
26,0 [1.02]  
18,0  
26,0 [1.02]  
[0.70]  
30,0 [1.18]  
25,0 [0.99]  
25,0 [0.99]  
30,0 [1.18]  
FIGURE 9. SZX-SMB-08  
FIGURE 10. SZX-SMB-14  
14 - 3 x O 1,2 [0.05] Holes  
8 - 3 X O 1,2 [0.05] Holes  
Max 24,0 [0.94]  
Max. 24,0 [0.94]  
7,7  
[0.30]  
2,7  
[0.11]  
2,6  
[0.10]  
2,7  
[0.11]  
7,7  
[0.30]  
2,6 [0.10]  
Max. 20,0  
[0.79]  
Max. 20,0  
[0.79]  
21,4 ± 0,2  
0.84 ± .008  
21,4 ± 0,2  
[0.84 ± .008]  
Honeywell Sensing and Control  
9
General Purpose  
Power Relays  
SZR-MY Series  
FIGURE 11. SZX-SMB-08P  
FIGURE 12. SZX-SMB-14P  
4,3  
[0.17]  
4,3  
[0.17]  
Max. 22,0  
[0.87]  
Max. 22,0 [0.87]  
2,7  
[0.11]  
2,7  
[0.11]  
2,6  
[0.10]  
2,6  
[0.10]  
Max. 16,5  
[0.65]  
13,2  
[0.52]  
Max. 16,5  
[0.65]  
4,4  
13,2  
[0.17]  
[0.52]  
14 - O 2,0 [0.08] Holes  
4,2  
[0.17]  
8 - O 2,0 [0.08] Holes  
4,2  
[0.17]  
WARRANTY/REMEDY  
While we provide application assistance  
Honeywell warrants goods of its manufacture as  
being free of defective materials and faulty  
workmanship. Contact your local sales office for  
warranty information. If warranted goods are  
returned to Honeywell during the period of  
coverage, Honeywell will repair or replace without  
charge those items it finds defective. The  
foregoing is Buyer’s sole remedy and is in lieu  
of all other warranties, expressed or implied,  
including those of merchantability and fitness  
for a particular purpose.  
personally, through our literature and the  
Honeywell web site, it is up to the customer to  
determine the suitability of the product in the  
application.  
For application assistance, current specifications,  
or name of the nearest Authorized Distributor,  
contact a nearby sales office. Or call:  
1-800-537-6945 USA/Canada  
1-815-235-6847 International  
FAX  
1-815-235-6545 USA  
INTERNET  
Specifications may change without notice. The  
information we supply is believed to be accurate  
and reliable as of this printing. However, we  
assume no responsibility for its use.  
www.honeywell.com/sensing  
info.sc@honeywell.com  
Sensing and Control  
www.honeywell.com/sensing  
Honeywell  
11 West Spring Street  
Freeport, Illinois 61032  
009550-4-EN IL50 GLO 0104 Printed in USA  
Copyright 2003-2004 Honeywell International Inc. All Rights Reserved.  

相关型号:

SZR-MY2-D1-AC220-240V

Power/Signal Relay
HONEYWELL

SZR-MY2-D1-AC6V

Power/Signal Relay
HONEYWELL

SZR-MY2-D1-DC24V

Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount
HONEYWELL

SZR-MY2-D1-DC6V

Power/Signal Relay
HONEYWELL

SZR-MY2-N1-AC220-240V

Power/Signal Relay
HONEYWELL

SZR-MY2-N1-AC220V

Power/Signal Relay, DPDT, Momentary, 1100mW (Coil), AC Input, AC Output, Panel Mount
HONEYWELL

SZR-MY2-N1-AC6V

Power/Signal Relay
HONEYWELL

SZR-MY2-N1-DC12V

Power/Signal Relay, DPDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount
HONEYWELL

SZR-MY2-X1-AC220-240V

Power/Signal Relay
HONEYWELL

SZR-MY2-X1-AC50V

Power/Signal Relay
HONEYWELL

SZR-MY2-X1-AC6V

Power/Signal Relay
HONEYWELL

SZR-MY2-X1-DC100V

Power/Signal Relay
HONEYWELL