UM10A10B01 [HONEYWELL]

Basic Switches; 微动开关
UM10A10B01
型号: UM10A10B01
厂家: Honeywell    Honeywell
描述:

Basic Switches
微动开关

开关
文件: 总94页 (文件大小:3549K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Basic Switches  
Door Switches  
Standard Bas ic Switches  
Sealed/High Temperature Switches  
Miniature/Subminiature Switches  
SUBMINIATURE/MINIATURE BASIC SWITCHES  
The U Series of subminiature basic switches are our newest line. The US is the  
smallest snap-action switch available. The UX and UM are versatile, low cost,  
full featured products with ample electrical capacity in a compact package.  
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . p. 2  
Index by Product Type . . . . . . . . . . . . . . . . . . . . . p. 3  
Selection Guides . . . . . . . . . . . . . . . . . . . . . . p. 4 to 7  
Catalog Listings/Order Guides . . . . . . . . . p. 8 to 93  
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . p. 94  
Catalog Listing/Page Number Index . . . . . . . p. 102  
SM subminiature basic switches are a versatile collection of small size and  
1
ample electrical capacities, including 11 amp power load handling and ⁄  
4
hp  
motor load. SX subminiature basic switches are smaller than SM switches,  
yet are big in performance and selection. They provide up to 7 amp power  
load capacity. V3 miniature basic switches put a 25 amp power load capacity  
and a choice of 11 other electrical ratings into a relatively small package with  
many choices of actuators, contact materials, and terminal designs. V7 minia-  
ture basic switches have electrical ratings up to 15 amps. Both commercial  
and European versions are UL recognized and CSA certified. The latter is also  
designed to meet all leading European approval agency requirements. TB  
miniature basic small double-break units can control 2, 3 or 4 isolated circuits.  
STANDARD BASIC SWITCHES  
Power load switching and motor handling capacity are among the attractions  
of thumb-size BZ/BA standard basic switches. Double-pole double-throw  
switching is added by DT switches. Where theres a need for reliable switch-  
ing of high capacity systems involving DC motors and solenoids, MT magnet-  
ic blow-out switches do the job. The 3MN has double-break switching. 6AS  
assemblies have two tandem mounted standard basic switches under a com-  
mon actuator.  
SEALED AND HIGH TEMPERATURE BASIC SWITCHES  
Specially adapted basic switches include: SE/XE environment-proof switch-  
es which protect subminiature SM/SX basic switches within a sealed hous-  
ing; HM hermetically sealed switches are interchangeable in operating point  
with the SM switches; HS hermetically sealed switches which parallel the size  
and mounting scheme of the standard basic switches; and HT high temper-  
ature switches for use up to +1000°F.  
DOOR SWITCHES  
AC, WW and DM switches automatically cut power when a service door or  
drawer is opened.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control  
1
Basic Switches  
Subminiature/Miniature  
ELECTRICAL DATA AND UL CODES  
MINIATURE/SUBMINIATURE BASIC SWITCHES  
Most of the switches in this section are UL recognized and CSA  
certified. The current and voltage values shown are based on  
test conditions specified by these agencies. Electrical life of the  
switch is influenced by each application condition as well as by  
voltage and current.  
Circuitry  
Single-pole  
double-throw  
Electrical Data  
UL rating:  
4 amps, 250 vac.  
S
Single-pole  
double-throw  
T UL/CSA rating:  
11 amps and 1/3 hp, 125, 250, or 277  
vac;  
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;  
4 amps, 125 vac ‘‘L’’ (lamp load).  
Circuitry  
Single-pole  
double-throw  
Electrical Data  
A 5 amps res., 3 amps ind., (sea level),  
4 amps res., 2 amps ind., (50,000  
feet), 28 vdc  
TT UL/CSA rating:  
10 amps and 1/3 hp, 125 or 250 vac;  
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;  
4 amps, 125 vac ‘‘L’’ (lamp load).  
5 amps res. or ind. 115 vac, 60 Hz.  
UL/CSA rating: 5 amps, 250 vac.  
Single-pole  
double-throw  
unless  
otherwise  
noted in  
UU 10 amps res., 10 amps ind., (sea  
level),  
Single-pole  
double-throw  
B 7 amps res., 4 amps ind., (sea level),  
7 amps res., 2.5 amps ind., (50,000  
feet), 28 vdc.  
6 amps ind. (50,000 feet), 6 amps  
motor load, 30 vdc.  
UL/CSA rating: 7 amps, 250 vac.  
U UL/CSA rating:  
Single-pole  
double-throw  
C
3.5 amps res., 2 amps ind., (sea level),  
3.5 amps res., 1.5 amps ind., (50,000  
feet), 28 vdc.  
order guide  
15.1 amps and 1/2 hp, 125 or 250 vac.  
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;  
5 amps, 120 vac ‘‘L’’ (lamp load).  
UL rating: 7 amps, 250 vac.  
Single-pole  
double-throw  
VV UL/CSA rating:  
3 amps-125, 250, 277 vac;  
1/10 hp-250 vac  
Single-pole  
double-throw  
D 1 amp res., 0.5 amp ind., (sea level  
and 50,000 feet), 28 vdc.  
UL/CSA rating: 1 amp, 125 vac.  
Single-pole  
double-throw  
V UL/CSA rating:  
Single-pole  
double-throw  
E
F
3 amps res., 2 amps ind., (sea level),  
28 vdc.  
UL rating: 3 amps, 250 vac.  
10 amps and 1/4 hp, 125 or 250 vac;  
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;  
3 amps, 125 vac ‘‘L’’ (lamp load).  
Single-pole  
double-throw  
7 amps res., 4 amps ind., 2.5 amps  
lamp load, (sea level),  
4 amps res., 2.5 amps ind., 2.5 amps  
lamp load, (50,000 feet), 28 vdc.  
7 amps res., 7 amps ind., 2 amps lamp  
load, 115 vac, 60 Hz (sea level).  
Single-pole  
double-throw  
W 10 amps, 250 vac or 28 vdc;  
1/2 amp, 125 vdc; 1/4 amp, 250 vdc.  
Single-pole  
double-throw  
X UL rating:  
1 amp, 125 vac.  
Single-pole  
double-throw  
Y 10 amps and 1/3 hp, 125 or 250 vac;  
Single-pole  
double-throw  
G 2 amps res., lamp ind., (sea level)  
4 amps, 125 vac ‘‘L’’ (lamp load).  
28 vdc.  
Single-pole  
double-throw  
YY UL/CSA rating:  
5 amps-125, 250, 277 vac  
1/10 hp-250 vac  
Single-pole  
double-throw  
H .010 amp res. and ind., (sea level).  
28 vdc.  
UL/CSA rating: 1 amp, 125 vac.  
Two-circuit  
double-break  
Z 10 amps, 125 or 250 vac, or 30 vdc.  
UL/CSA rating:  
Single-pole  
double-throw  
I
7 amps res., 4 amps ind., (sea level),  
28 vdc.  
10 amps, 125 or 250 vac; 1/2 hp, 125  
vac.  
Single-pole  
double-throw  
J
5 amps res., 3 amps ind., (sea level),  
5 amps res., 2.5 amps ind.,  
(50,000 feet), 28 vdc.  
Four-circuit  
UL rating: 5 amps, 250 vac.  
double-break  
Single-pole  
K UL rating:  
double-throw  
5 amps, 125 or 250 vac.  
Single-pole  
ZZ UL rating:  
double-throw  
5 amps and 1/10 hp.  
125 or 250 vac.  
Single-pole  
double-throw  
L 1 amp res., 1/2 amp ind.,  
(sea level) 28 vdc.  
Single-pole  
double-throw  
AA UL rating:  
Single-pole  
double-throw  
M UL rating:  
20 amps, 277 vac.  
1 hp, 125 vac; 2 hp, 250 vac.  
11 amps and 1/4 hp, 125 or 250 vac.  
Single-pole  
double-throw  
N 1 amp res., 0.5 amp ind., 30 vdc.  
Single-pole  
double-throw  
BB UL rating:  
UL rating: 1 amp, 125 vac.  
25 amps, 277 vac.  
1 hp, 125 vac; 2 hp, 250 vac.  
Single-pole  
P
1 amp res., 30 vdc.  
double-throw  
UL rating: .1 amp, 125 vac.  
Single-pole  
double-throw  
R 5 amps res., 3 amps ind., 2.4 amps  
lamp load (sea level),  
5 amps res., 2.5 amps ind., 2.4 amps  
lamp load, (50,000 feet), 28 vdc.  
5 amps res., 5 amps ind., 1.5 amps  
lamp load, 115 vac. 60 Hz (sea level)  
20 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
Standard  
ELECTRICAL DATA AND UL CODES STANDARD BASIC  
SWITCHES  
Electrical Data and  
UL Codes  
Circuitry  
Double-pole  
double-throw  
Most of the switches in this section are UL recognized and CSA  
certified. The current and voltage values shown are based on  
test conditions specified by these agencies. Electrical life of the  
switch is influenced by each application condition as well as by  
voltage and current. For application assistance contact the 800  
number.  
J
10 amps, 125 or 250 vac;  
0.3 amp, 125 vdc; 0.15 amp,  
250 vdc.  
UL Code L59  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
K Rating established with  
switch non-polarized  
10 amps, 125 vac or vdc;  
⁄ hp, 125 vac or vdc.  
UL Code L 168  
1
4
Non-polarized:  
10 amps res. or 1⁄  
hp, 125 vdc;  
4
3 amps max. res. 250 vdc.  
Polarized*:  
Electrical Data and  
10 amps res. or 1⁄  
2
hp, 125 vdc;  
Circuitry  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
UL Codes  
3 amps max. res., 250 vdc.  
A 15 amps, 125, 250 or 480 vac;  
*To polarize, connect negative side of line to common terminal. To  
achieve the same effect, mount switch with brass screws, using a  
1
8
hp, 125 vac; 1⁄  
4
hp, 250 vac;  
non-magnetic barrier (at least 1⁄  
mounting surface.  
4
thick) between the switch and  
1
2  
amp, 125 vdc; 1⁄  
4
amp,  
250 vdc.  
UL Code L96  
M25 amps, 125, 250 or 480 vac;  
3
4  
hp, 125 vac; 11⁄  
4
amp, 250 vac.  
amp, 250 vdc.  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
B
C
5 amps, 125, 250 or 480 vac;  
1
1 amp, 125 vdc; 1⁄  
UL Code L58  
2
amp, 125 vdc; 1⁄  
UL Code L35  
4
amp, 250 vdc.  
Two-circuit  
double-break  
2  
Single-pole  
double-throw  
P
1 amp, 125 VAC  
UL Code L22  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
10 amps, 125, 250 or 480 vac;  
UL Code L8  
Single-pole  
double-throw  
R
10 amps, 125 or 250 vac;  
1
3  
hp, 125 vac; 3⁄  
4
hp, 250 vac;  
1
2  
amp, 125 vdc; 1⁄  
4
amp,  
250 vdc.  
UL Code L115  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
D 15 amps, 125, 250 or 480 vac;  
1
Single-pole  
double-throw  
S
10 amps, 125 or 250 vac;  
1
8  
hp, 125 vac; 1⁄  
UL Code L103  
4
hp, 250 vac.  
3  
hp, 125 or 250 vac.  
UL Code L93  
T 15 amps, 125, 250 or 480 vac;  
1 amp, 125 vdc; 1⁄  
2
amp, 250 vdc;  
4  
hp, 125 vac; 1⁄  
2
hp, 250 vac  
1
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
E
F
15 amps, 125, 250 or 480 vac;  
1
Two-circuit  
double-break  
Single-pole  
double-throw  
4
hp, 125 vac, 1⁄  
2
hp, 250 vac;  
amp, 125 vdc; 1⁄  
amp, 250 vdc.  
UL Code L67  
UL Code L73  
1
2  
4
U 5 amps, 250 vac.  
UL Code L4  
V Motor Control  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
22 amps, 125, 250 or 480 vac;  
1
15 amps, 120, 240, 480 or 600  
vac;  
2  
hp, 125 vac, 1 hp, 250 vac.  
UL Code L161  
Two-circuit  
double-break  
1
⁄ hp, 120 vac; 1 hp, 240 vac;  
2
0.8 amp, 115 vdc; 0.4 amp,  
230 vdc.  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
G 20 amps, 125, 250 or 480 vac;  
10 amps, 125 vac ‘‘L’’ (tungsten  
lamp load);  
Single-pole  
single-throw  
(N.C.)  
W 20 amps, 125, 250 or 277 vac;  
3
4  
hp, 125 vac; 1⁄  
hp, 250 vac  
2
UL Code L178B  
1 hp, 125 vac; 2 hp, 250 vac;  
1
2  
amp, 125 vdc; 1⁄  
amp,  
4
X 15 amps, 125, 250 or 480 vac;  
250 vdc.  
UL Code L23  
2 amps, 600 vac;  
1
8
hp, 125 vac; 1⁄  
4
hp, 250 vac;  
Single-pole  
double-throw  
1
2  
amp, 125 vdc; 1⁄  
4
amp,  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
H Motor Control  
250 vdc.  
UL Code L74  
25 amps, 125, 250 or 480 vac;  
1 hp, 125 vac; 2 hp, 250 vac;  
Pilot Duty—750 VA, 125, 250,  
or 277 vac.  
Y 20 amps, 125, 250 or 480 vac;  
3
4  
hp, 125 vac; 11⁄  
2
hp, 250 vac; UL  
Single-pole  
double-throw  
unless  
I
10 amps, 125, 250 or 480 vac;  
Code L17  
Single-pole  
double-throw  
1
8  
hp, 125 vac; 1⁄  
hp, 250 vac;  
4
UL Code L95  
otherwise noted  
in order guide  
46 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
Operating Characteristics  
ELECTROMECHANICAL SWITCHES  
Definitions below explain the meaning of Free Pos ition (F.P.)—Position of switch Operating Force (O.F.)—Amount of  
operating characteristics. Characteristics plunger or actuator when no external force applied to switch plunger or actua-  
shown in tables throughout catalog were force is applied (other than gravity).  
chosen as most significant. They are tak-  
tor to cause contact snap-over.’ Note in  
the case of adjustable actuators, the force  
en at normal room temperature and hu- Full Overtravel Force—Force required is measured from the maximum length  
midity. These may vary as temperature to attain full overtravel of actuator.  
and humidity conditions differ. Sketches  
position of the lever.  
show how characteristics are measured Operating Pos ition (O.P.)—Position of Overtravel (O.T.)—Plunger or actuator  
for in-line plunger actuation.  
switch plunger or actuator at which point travel safely available beyond operating  
contacts snap from normal to operated position.  
Linear dimensions for in-line actuation position. Note that in the case of flexible or  
are from top of plunger to a reference line, adjustable actuators, the operating posi- Pretravel (P.T.)—Distance or angle trav-  
usually the center of the mounting holes. tion is measured from the end of the lever eled in moving plunger or actuator from  
or its maximum length. Location of oper- free position to operating position.  
Differential Travel (D.T.)—Plunger or ac- ating position measurement shown on  
tuator travel from point where contacts mounting dimension drawings.  
‘‘snap-over’’ to point where they snap-  
back.’  
Releas e Force (R.F.)—Amount of force  
still applied to switch plunger or actuator  
at moment contacts snap from operated  
position to unoperated position.  
Total Travel (T.T.)—Distance from actua-  
tor free position to overtravel limit posi-  
tion.  
IN-LINE PLUNGER ACTUATION  
94 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
Operating Characteristics  
FULL LOAD AND LOCKED ROTOR CURRENTS FOR SINGLE PHASE AND DC MOTORS  
Alternating Current  
Direct Current  
115 Volts  
Locked  
230 Volts  
Locked  
115 Volts  
Locked  
230 Volts  
Locked  
Full  
Full  
Full  
Full  
HP  
Load  
Rotor  
Load  
Rotor  
Load  
Rotor  
Load  
Rotor  
2
24.0  
20.0  
16.0  
13.8  
9.8  
7.2  
5.8  
4.4  
3.8  
144.0  
120.0  
96.0  
82.8  
58.8  
43.2  
34.8  
26.4  
22.8  
18.0  
9.0  
12.0  
10.0  
8.0  
6.9  
4.9  
3.6  
2.9  
2.2  
1.9  
1.5  
72.0  
60.0  
48.0  
41.4  
29.4  
21.6  
17.4  
13.2  
11.4  
9.0  
17.0  
13.2  
9.6  
7.4  
5.4  
3.8  
3.0  
2.4  
2.2  
2.0  
170.0  
132.0  
96.0  
74.0  
54.0  
38.0  
30.0  
24.0  
22.0  
20.0  
8.5  
6.6  
4.8  
3.7  
2.7  
1.9  
1.5  
1.2  
1.1  
1.0  
85.0  
66.0  
48.0  
37.0  
27.0  
19.0  
15.0  
12.0  
11.0  
10.0  
11⁄  
2
1
3
4  
1
1
1
1
1
1
1
2
3  
4  
6  
8  
10  
3.0  
1.5  
20  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 95  
Basic Switches  
B Type Switches Performance Information  
ELECTRICAL DATA CHART  
Ampe re s  
Catalog  
Lis ting  
(contact  
gap)  
Curre nt  
Carrying  
Capacity  
Inrus h  
N.C.  
Re s is tive Ckt.  
Motor  
Lamp  
Inductive 2  
N.O.  
Ckt.  
N.C.  
Ckt.  
N.O.  
Ckt.  
N.C.  
Ckt.  
N.O.  
Ckt.  
Se a  
Le ve l  
50,000  
Fe e t  
Voltage Max.1  
VDC  
8
14  
30  
125  
250  
BZ-3YT*  
.036 in.  
0,91 mm  
5
5
5
5
5
10  
10  
10  
1
30  
30  
30  
10  
6
15  
15  
15  
10  
6
5
5
5
2
2.5  
2.5  
2.5  
2
3
3
3
1
1.5  
1.5  
1.5  
1
10  
10  
10  
0.6  
0.4  
10  
10  
5
0.4  
0.3  
0.6  
1.2  
1.2  
0.6  
0.6  
VAC  
120  
240  
277  
BZ-3YT*  
.036 in.  
0,91 mm  
5
5
5
5
5
5
30  
30  
30  
15  
15  
15  
5
5
5
2.5  
2.5  
2.5  
3
3
3
1.5  
1.5  
1.5  
5
5
5
5
5
5
VDC  
8
14  
30  
125  
230  
BM-2R  
.020 in.  
0,50 mm  
22  
22  
22  
22  
22  
15  
15  
2
0.4  
0.2  
30  
30  
30  
4
15  
15  
15  
4
5
5
5
0.8  
0.4  
2.5  
2.5  
2.5  
0.4  
0.2  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
8
5
1
.03  
.02  
7
5
1
.02  
.01  
2
2
VAC  
125  
250  
277  
460  
BM-2R  
.020 in.  
0,50 mm  
22  
22  
22  
22  
22  
22  
22  
22  
35  
35  
35  
35  
20  
20  
20  
20  
5.8  
5.8  
5.8  
5.8  
3.4  
3.4  
3.4  
3.4  
3.5  
3.5  
3.5  
3.5  
2.0  
2.0  
2.0  
2.0  
22  
22  
22  
22  
22  
22  
22  
22  
VDC  
8
14  
30  
125  
230  
BA-2R  
.020 in.  
0,50 mm  
20  
20  
20  
20  
20  
20  
20  
5
0.5  
0.25  
30  
30  
30  
4
15  
15  
15  
4
5
5
5
0.8  
0.4  
2.5  
2.5  
2.5  
0.4  
0.2  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
15  
10  
5
.05  
.03  
15  
8
2
.03  
.02  
2
2
VAC  
120  
240  
277  
460  
BA-2R  
.020 in.  
0,50 mm  
20  
20  
20  
20  
20  
20  
20  
20  
75  
75  
75  
75  
75  
75  
75  
75  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
20  
20  
20  
20  
20  
20  
20  
20  
VDC  
8
14  
30  
125  
250  
BE-2R  
.020 in.  
0,50 mm  
25  
25  
25  
25  
25  
25  
25  
5
0.5  
0.25  
30  
30  
30  
4
15  
15  
15  
4
5
5
5
0.8  
0.4  
2.5  
2.5  
2.5  
0.8  
0.4  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
15  
10  
5
.05  
.03  
15  
8
2
.03  
.02  
2
2
VAC  
120  
240  
277  
460  
BE-2R  
.020 in.  
0,50 mm  
25  
25  
25  
25  
25  
25  
25  
25  
96  
96  
96  
96  
96  
96  
96  
96  
16  
16  
16  
16  
16  
16  
16  
16  
10  
10  
10  
10  
10  
10  
10  
10  
25  
25  
25  
25  
VAC  
125  
250  
277  
BZ-R  
.006 in.  
0,15 mm  
15  
15  
15  
15  
15  
15  
30  
30  
30  
15  
15  
15  
5
5
5
2.5  
2.5  
2.5  
3
3
3
1.5  
1.5  
1.5  
15  
15  
15  
15  
15  
15  
VDC  
8
14  
30  
125  
230  
BZ-1R  
.010 in.  
0,25 mm  
15  
15  
15  
15  
15  
15  
15  
2
0.4  
0.2  
30  
30  
30  
4
15  
15  
15  
4
5
5
5
0.8  
0.4  
2.5  
2.5  
2.5  
0.8  
0.4  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
8
5
1
0.03  
0.02  
7
5
1
0.01  
0.01  
2
2
VAC  
125  
250  
277  
460  
BZ-1R  
.010 in.  
0,25 mm  
15  
15  
15  
15  
15  
15  
15  
15  
30  
30  
30  
30  
15  
15  
15  
15  
5
5
5
5
2.5  
2.5  
2.5  
2.5  
3
3
3
3
1.5  
1.5  
1.5  
1.5  
15  
15  
15  
15  
15  
15  
15  
15  
*Ampere levels for BZ-3YT applicable only if common terminal is not used and switch is used as a shorting bar switch.  
96 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
B Type Switches Performance Information  
ELECTRICAL DATA CHART, cont.  
Ampe re s  
Catalog  
Lis ting  
(contact  
gap)  
Curre nt  
Carrying  
Capacity  
Inrus h  
N.C.  
Re s is tive Ckt.  
Motor  
Lamp  
Inductive 2  
N.O.  
Ckt.  
N.C.  
Ckt.  
N.O.  
Ckt.  
N.C.  
Ckt.  
N.O.  
Ckt.  
Se a  
Le ve l  
50,000  
Fe e t  
Voltage Max.1  
VDC  
8
14  
30  
125  
230  
BZ-2R  
.020 in.  
0.50 mm  
15  
15  
15  
15  
15  
15  
15  
6
0.4  
0.2  
30  
30  
30  
4
15  
15  
15  
4
5
5
5
0.8  
0.4  
2.5  
2.5  
2.5  
0.8  
0.4  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
15  
10  
5
0.05  
0.03  
15  
8
2
0.03  
0.02  
2
2
VAC  
125  
250  
277  
460  
BZ-2R  
.020 in.  
0,50 mm  
15  
15  
15  
15  
15  
15  
15  
15  
30  
30  
30  
30  
15  
15  
15  
15  
5
5
5
5
2.5  
2.5  
2.5  
2.5  
3
3
3
3
1.5  
1.5  
1.5  
1.5  
15  
15  
15  
15  
15  
15  
15  
15  
VDC  
8
14  
30  
125  
250  
BZ-3R  
.036 in.  
0,91 mm  
15  
15  
15  
15  
15  
15  
15  
10  
0.6  
0.3  
30  
30  
30  
6
15  
15  
15  
6
5
5
5
1.2  
0.6  
2.5  
2.5  
2.5  
1.2  
0.6  
3
3
3
0.6  
0.3  
1.5  
1.5  
1.5  
0.6  
0.3  
15  
15  
10  
0.1  
0.05  
15  
15  
5
0.05  
0.03  
3
3
VAC  
125  
250  
277  
460  
BZ-3R  
.036 in.  
0,91 mm  
15  
15  
15  
15  
15  
15  
15  
15  
30  
30  
30  
30  
15  
15  
15  
15  
5
5
5
4
2.5  
2.5  
2.5  
2.5  
3
3
3
3
1.5  
1.5  
1.5  
1.5  
15  
15  
15  
15  
15  
15  
15  
15  
VDC  
8
14  
30  
125  
250  
BZ-7R  
.070 in.  
1,78 mm  
30  
15  
15  
15  
15  
15  
15  
15  
0.75  
0.3  
15  
30  
30  
7.5  
3
5
2.5  
5
5
1.5  
0.6  
3
1.5  
3
3
0.75  
0.3  
15  
15  
15  
10  
0.4  
0.2  
15  
7.5  
0.2  
0.1  
15  
15  
7.5  
3
2.5  
2.5  
1.5  
0.6  
1.5  
1.5  
0.75  
0.3  
VAC  
120  
240  
277  
460  
BZ-7R  
.070 in.  
1,78 mm  
15  
15  
15  
15  
15  
15  
15  
15  
30  
30  
30  
30  
15  
15  
15  
15  
5
5
5
5
2.5  
2.5  
2.5  
2.5  
3
3
3
3
1.5  
1.5  
1.5  
1.5  
15  
15  
15  
15  
15  
15  
15  
15  
1 For a 86F (30C) max. temperature rise at terminals, not opening or closing the load (at sea level).  
2 Data established with a 75% power factor on AC loads.  
TEST CONDITIONS  
Switch contact life is affected by electrical conditions and other  
factors, such as: temperature, humidity, airborne contamina-  
tion, vibration, amount and rate of plunger travel, and cycling  
rate. Our Evaluation Laboratory tests are conducted using pro-  
cedures and practices common to UL and Military Specifica-  
tions. The following conditions generally apply.  
Temperature:  
Humidity:  
AC Cycle Rate:  
DC Cycle Rate:  
On-off Time:  
Room Ambient (70F, 21 C).  
Room Ambient (50%).  
60 operations/minute.  
20 operations/minute.  
Equal and compatible with above cycling rates.  
Power Factor (AC): Approximately 75%.  
Inductance (DC):  
Circuit Loading:  
Travel Plunger:  
Actuation:  
MIL-I-81023 Inductor.  
One throw only on a SPDT switch during any test procedure. Both throws are evaluated separately.  
Full switch travel is used.  
Linear motion.  
Overtravel Force:  
1 to 3 lbs. from spring-loaded actuators.  
MICRO SWITCH believes that with the following voltage and  
current values and under the test conditions set forth below  
switch life of100,000 closures, 95% survival can be expected. It  
is a starting point for user evaluation and provides guidelines  
on the switches identified. Because of the numerous electrical  
conditions listed, not every current and voltage level has ac-  
tually been tested on every switch and certain figures have  
been extrapolated. For specific switch selection, customers  
should evaluate switches under actual application conditions  
or by simulating all application conditions and requirements.  
The information set forth cannot substitute for the customers  
own product evaulation. It should never be published by a cus-  
tomer as a rating on their product.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 97  
Basic Switches  
Definitions of Terms  
Actuator – Mechanism of the switch or Double Break Contacts – (Twin break). Normally Open Contacts (N.O.) – Pro-  
switch enclosure which operates the con- This breaks the circuit in two places. Re- vide a normally open circuit when actua-  
tacts.  
ferred to as form Z circuitry also.  
tor is in free position.  
Auxiliary Actuator – A mechanism, sold  
separately, to provide basic switches with  
easier means of operation and adjust-  
ment and adapt switches to different op-  
erating motions by supplying supple-  
mental overtravel.  
Precis ion Snap-Acting Switch – An  
electromechanical switch having prede-  
termined and accurately controlled char-  
acteristics, and having a spring loaded  
quick make and break contact action.  
Form Z  
Double-Pole Double-Throw (DPDT) –  
Switches which make and break two sep-  
arate circuits. This circuit provides a nor-  
mally open and normally closed contact  
for each pole.  
Projection Contacts – A design in which  
one or more truncated projections are ar-  
ranged on the stationary contacts. When  
closed on the smooth, spherical surface  
of the opposing contact this configuration  
Bas ic Switch – A self-contained switch-  
ing unit. It can be used alone, gang-  
mounted, built into assemblies or en-  
closed in metal housings.  
Enclos ed Switch – A basic switch unit tends to break thru oxides and other film  
(contact block) enclosed in a durable contaminants to avoid the particulate  
metal housing. The enclosure protects contaminants. Used with silver contacts,  
the switching unit, provides mounting this design can be a useful substitute for  
means, and fitting for conduit connection. the more expensive gold or gold alloy  
Bifurcated Contacts – A movable con-  
tact, generally gold plated, which is  
forked to provide two contact mating sur-  
faces in a parallel, for more reliable con-  
tact.  
contact material.  
Environment-Proof Switch – A switch  
Break To open an electrical circuit.  
which is completely sealed to ensure con- Puls e Switch – Provides a single pulse of  
stant operating characteristics. Sealing current for each cycle of operation.  
Break Dis tance – The minimum open  
gap distance between stationary and  
movable objects.  
normally includes an O’ ring on actuator  
shaft and fused glass-to-metal terminal  
seals or complete potting and an elas-  
tomer plunger-case seal.  
Quick Connect Terminal – A plug-in type  
terminal designed for quick switch wiring.  
Characteris tics – This term is used by  
MICRO SWITCH in a restricted sense and  
refers only to switch operating character-  
istics such as pretravel, operating force,  
etc.  
Repeatability – Ability of a switch to re-  
peat its characteristics precisely from one  
operation to the next operation.  
Explos ion-Proof Switch – A UL listed  
switch capable of withstanding an inter-  
nal explosion of a specified gas without  
igniting surrounding gases.  
Single-Pole Double-Throw (SPDT) –  
Switch which may either make or break a  
circuit, depending on how it is wired. Also  
referred to as form C circuitry.  
Circuit – The contact arrangement with  
switch actuator and contacts in their nor-  
mal position.  
Hermetically Sealed Switch – A switch  
completely sealed to provide constant  
operating characteristics. All junctures  
made with metal-to-metal or glass-to-  
metal fusion.  
Dead break – Exists in all mechanical  
switches. Definition: When the switch  
plunger is being depressed, dead break  
is non-contact immediately before the  
plunger reaches the operating point.  
When the switch plunger is being re-  
leased, dead break is non-contact imme-  
diately before the plunger reaches the re-  
lease point. Dead break is expressed in  
distance of plunger travel during which  
the non-contact occurs. Manufacturing  
specifications for most BZ/BA basic  
Magnetic Blow-Out Switch – Contains a  
small permanent magnet which provides  
a means of switching high d-c loads. The  
magnet deflects arc to quench it.  
Form C  
Single-Pole Single-Throw (SPST)  
Switch with only one moving and one sta-  
tionary contact. Available either normally  
open (N.O.) also referred to as form A cir-  
cuitry; or normally closed (N.C.) also re-  
ferred to as form B circuitry.  
Maintained Contact Switch – Designed  
for applications requiring sustained con-  
tact after plunger has been released, but  
with provision for resetting.  
switches allow a maximum dead break of Make To close or establish an electrical  
0.00005 in. (0,001 mm) measured at the circuit.  
switch plunger. Switches are evaluated  
while moving the plunger with the switch  
Momentary Switch – A switch with con-  
tacts that return from operated condition  
Form A  
Form B  
installed in a 10 VDC, 0.100 ampere cir-  
to normal condition when actuating force  
cuit. This specifiction does not apply to  
is removed. Unless otherwise stated, all  
switches that have been in service or have  
switches in this catalog are momentary.  
not received proper handling or storage.  
Terminal Enclos ure – A housing that fits  
over switch terminals to protect against  
electrical shock and accidental shorting,  
and facilitate wiring.  
Mounting Dimens ions – All dimensions  
on the mounting dimension drawings in  
this catalog are subject to change without  
notice. Request current drawings from  
the nearest MICRO SWITCH Sales Office  
or write to Freeport.  
For applications sensitive to dead break,  
call Freeport for information on applica-  
ble electrical and mechanical conditions.  
Dead make – When the switch plunger is  
being depressed, dead make is non-con-  
tact immediately after the plunger reac-  
hes the release point. Dead make is ex-  
pressed as the distance of plunger travel  
during which the non-contact occurs.  
Non contact is a failure of open contacts  
to close (that is, the switch resistance ex-  
ceeds the specified value) within the  
specified range of plunger positions. If a  
plunger position is specified with respect  
to time, a non-contact is a contact miss.  
Two Circuit Switch – In one position,  
moving contacts complete one circuit, in  
the other position, contacts complete an-  
other separate circuit.  
Normally Clos ed Contacts (N.C.) – Pro-  
vide a normally closed circuit when actua-  
tor is in free position.  
98 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
US Series  
Subminiature  
NC  
NO  
PC Terminal Version  
C
FEATURES  
ELECTRICAL RATINGS  
Res is tive Load  
ɀ
ɀ
ɀ
ɀ
ɀ
MICRO SWITCHS smallest snap-action switch  
Choice of low energy or power duty electrical ratings  
Variety of integral actuators  
Temperature Range: 25° to +80°C (13° to +176°F)  
Weight: 0.2 grams (.007 oz.) – PC terminal type  
0.3 grams (.011 oz.) – solder terminal type  
Form C single-pole double-throw (SPDT) circuitry  
Gold Contacts  
US10 Type  
Silver Contacts  
US20 Type  
Voltage  
30 VDC  
125 VAC  
0.1 A  
0.1 A  
0.5 A  
0.1 A  
ɀ
ORDER GUIDE SOLDER TERMINALS  
O.F. max.  
grams  
R.F. min.  
g
P.T. max.  
mm  
O.T. min.  
mm  
D.T. max.  
mm  
O.P  
mm  
Contact Type  
Actuator  
oz.  
ounces  
inches  
inches  
inches  
inches  
Gold, 0.1 Amp A pin plunger  
100  
10  
0,3  
0,1  
0,1  
5,4 ± 0,15  
3.527  
.353  
.012  
.004  
.004  
.213 ± .006  
C flat lever  
25  
.88  
2,0  
.071  
2,4  
.094  
0,4  
.016  
0,7  
.028  
6,4 ± 0,6  
.252 ± .024  
E simulated  
roller lever  
30  
1.058  
2,0  
.071  
2,2  
.087  
0,3  
.012  
0,7  
.028  
6,7 ± 0,5  
.264 ± .020  
Silver, 0.5 Amp A pin plunger  
100  
3.527  
10  
.353  
0,3  
.012  
0,1  
.004  
0,1  
.004  
5,4 ± 0,15  
.213 ± .006  
C flat lever  
25  
.88  
2,0  
.071  
2,4  
.094  
0,4  
.016  
0,7  
.028  
6,4 ± 0,6  
.252 ± .024  
E simulated  
roller lever  
30  
1.058  
2,0  
.071  
2,2  
.087  
0,3  
.012  
0,7  
.028  
6,7 ± 0,5  
.264 ± .020  
ORDER GUIDE PC STRAIGHT TERMINALS  
O.F. max.  
grams  
R.F. min.  
g
ounces  
P.T. max.  
mm  
inches  
O.T. min.  
mm  
inches  
D.T. max.  
mm  
inches  
O.P  
mm  
inches  
Contact Type  
Actuator  
oz.  
Gold, 0.1 Amp A pin plunger  
100  
3.527  
10  
.353  
0,3  
.012  
0,1  
.004  
0,1  
.004  
4,8 ± 0,15  
.189 ± .006  
C flat lever  
25  
.88  
1,0  
.035  
2,4  
.094  
0,4  
.016  
0,7  
.028  
5,8 ± 0,7  
.228 ± .028  
E simulated  
roller lever  
30  
1.058  
1,0  
.035  
2,2  
.087  
0,3  
.012  
0,7  
.028  
6,1 ± 0,7  
.240 ± .028  
Silver, 0.5 Amp A pin plunger  
100  
3.527  
10  
.353  
0,3  
.012  
0,1  
.004  
0,1  
.004  
4,8 ± 0,15  
.189 ± .006  
C flat lever  
25  
.88  
1,0  
.035  
2,4  
.094  
0,4  
.016  
0,7  
.028  
5,8 ± 0,7  
.228 ± .028  
E simulated  
roller lever  
30  
1.058  
1,0  
.035  
2,2  
.087  
0,3  
.012  
0,7  
.028  
6,1 ± 0,7  
.240 ± .028  
OTHER TERMINATION TYPES ARE AVAILABLE  
For PC right angle, change 2nd set of numbers to 50 (Example: US10D50A00)  
For PC left angle, change 2nd set of numbers to 60 (Example: US10D60A00)  
8
HoneywelSensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
US Series  
Subminiature  
mm  
in.  
MOUNTING DIMENSIONS  
(for reference only)  
Solder Terminal Switches (with mounting holes )  
Pin plunger (Type A)  
Flat lever (Type C)  
Simulated roller (Type E)  
PC Board Terminals Switches  
Pin plunger (Type A)  
Right angle terminal (Type 50)  
Left angle terminal (Type 60)  
Flat lever (Type C)  
Simulated roller (Type E)  
Mounting s crew s ize is m 1,4.  
Maximum tightening torque is 1 kg-cm.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control  
9
Basic Switches  
UX Series  
Subminiature  
NC  
NO  
C
ELECTRICAL RATINGS (in amps )  
Silver Contacts  
FEATURES  
Gold Contacts  
UX10 Type  
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
Compact size – helps minimize equipment size  
Choice of low energy or power duty electrical ratings  
Variety of integral actuators  
Temperature Range: –25° to +85°C (–13 to 185°F)  
Weight: 0.5 grams (.018 oz.)  
Voltage  
UX40 Type  
UX30 Type  
125 VAC*  
30 VDC  
6 VDC  
3 A  
2 A  
1 A  
1 A  
0.1 A  
0.1 A  
5 mA  
2 mA  
1 mA  
12 VDC  
24 VDC  
UL/CSA marking designations  
Form C single-pole double-throw (SPDT) circuitry  
*UL/CSA rating. UL File No. E12252. UL Standard 1054.CSA file LR23413M167  
ORDER GUIDE  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.F. max.  
grams  
oz.  
O.P  
mm  
inches  
g
mm  
inches  
mm  
inches  
mm  
inches  
Rating  
Actuator  
ounces  
Gold,  
0.1 Amp 125 VAC  
A pin plunger  
75  
2.65  
10  
.353  
0,5  
.020  
0,25  
.010  
0,12  
.005  
5,5 ± 0,2  
.217 ± .008  
150  
5.3  
20  
.705  
0,5  
.020  
0,25  
.010  
0,12  
.005  
5,5 ± 0,2  
.217 ± .008  
C flat lever  
25  
.88  
2,5  
.088  
2,1  
.083  
0,55  
.022  
0,50  
.020  
6,8 ± 1,0  
.268 ± .039  
50  
5,0  
2,1  
0,55  
0,50  
6,8 ± 1,0  
1.76  
.176  
.083  
.022  
.020  
.268 ± .039  
E roller lever  
simulated  
27  
.95  
55  
2,0  
.071  
4,0  
2,1  
.083  
2,1  
0,50  
.020  
0,50  
.020  
0,50  
.020  
0,50  
.020  
9,5 ± 1,0  
.374 ± .039  
9,5 ± 1,0  
1.94  
.141  
.083  
.374 ± .039  
Silver,  
1 Amp 125 VAC  
A pin plunger  
C flat lever  
75  
2.65  
10  
.353  
0,5  
.020  
0,25  
.010  
0,12  
.005  
5,5 ± 0,2  
.217 ± .008  
25  
.88  
2,5  
.088  
2,1  
.083  
0,55  
.022  
0,50  
.020  
6,8 ± 1,0  
.268 ± .039  
E roller lever  
simulated  
27  
.95  
2,0  
.071  
2,1  
.083  
0,50  
.020  
0,50  
.020  
9,5 ± 1,0  
.374 ± .039  
Silver,  
3 Amp 125 VAC  
A pin plunger  
150  
5.3  
20  
.705  
0,5  
.020  
0,25  
.010  
0,12  
.005  
5,5 ± 0,2  
.217 ± .008  
C flat lever  
50  
1.76  
5,0  
.176  
2,1  
.083  
0,55  
.022  
0,50  
.020  
6,8 ± 1,0  
.268 ± .039  
E roller lever  
simulated  
55  
1.94  
4,0  
.141  
2,1  
.083  
0,50  
.020  
0,50  
.020  
9,5 ± 1,0  
.374 ± .039  
OTHER TERMINATION TYPES ARE AVAILABLE  
For PC right angle, change 2nd set of numbers to 50 (Example: UX10C50A01)  
For PC left angle, change 2nd set of numbers to 60 (Example: UX10C60A01)  
10 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
UX Series  
Subminiature  
mm  
in.  
MOUNTING DIMENSIONS (for reference only)  
Pin plunger (Type A)  
Solder terminals – Type 10  
PC board terminals – Type 30  
PC board mounting  
Type 50  
Type 60  
LEVER ACTUATORS  
UX Series switches with lever actuators can be operated by  
cams or slides. They require lower operating forces than pin  
plunger switches.  
Flat levers are .520 in. (13,2 mm) long and simulated roller lev-  
ers are .480 in. (12,2 mm) long.  
Flat lever (Type C)  
Simulated Roller Lever (Type E)  
Mounting screw size is 2 mm.  
Maximum tightening torque is 1 kg-cm.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 11  
Basic Switches  
UM Series  
Subminiature  
NC  
NO  
ELECTRICAL RATINGS (in amps )  
C
UM50E  
Silver Contacts  
Voltage Res is tive Inductive Res is tive Inductive  
UM40B/D  
Silver Contacts  
UM10A/B/D/E  
Gold Contacts  
Res is tive  
FEATURES  
ɀ
Choice of low energy or power duty electrical  
ratings  
125 VAC  
250 VAC  
30 VDC  
5
5
5
3
3
3*  
3
3
3
2
2
2*  
0.1  
0.1  
0.1  
ɀ
ɀ
Variety of integral actuators  
Temperature Range: 25° to +85°C (13° to  
185°F)  
*Time constant for DC inductive loads: less than 7 msec.  
UL File No. E12252, CSA File LR23413M167  
ɀ
ɀ
ɀ
Weight: 2 grams (.07 oz.)  
UL/CSA/VDE/SEMKO marking designations  
Form C single-pole double-throw (SPDT) circui-  
try  
ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS  
O.F. max.  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P  
mm  
inches  
Actuator  
grams  
g
mm  
mm  
mm  
Rating  
Length  
oz.  
ounces  
inches  
inches  
inches  
A pin plunger  
25  
.88  
2
.071  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
0.1 Amp  
250 VAC  
50  
1.76  
7,5  
.265  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
100  
3.57  
15  
.529  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
150  
5.3  
20  
.705  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
B flat lever  
18mm  
10  
.35  
0,4  
.014  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
20  
.7  
1,7  
.060  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
40  
1.4  
3,5  
.123  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
C flat lever  
20mm  
8
.28  
0,35  
.012  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
D flat lever  
26mm  
12  
.4  
1,2  
.042  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
25  
.88  
2,5  
.088  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
45  
3,0  
3,5  
1,6  
1,0  
8,8 ± 1,2  
1.6  
.106  
.138  
.063  
.039  
.346 ± .047  
12 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
UM Series  
Subminiature  
ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS cont.  
O.F. max.  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P  
mm  
inches  
Actuator  
grams  
g
mm  
mm  
mm  
Rating  
Length  
oz.  
ounces  
inches  
inches  
inches  
0.1 Amp  
250 VAC  
J flat lever  
60mm  
6
.2  
0,5  
.018  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
15  
.52  
1,0  
.035  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
20  
.7  
1,0  
.035  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
0.1 Amp  
250 VAC  
E simulated  
roller lever, radius  
2,5mm,  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
19mm  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
H simulated  
roller lever, radius  
1,3mm,  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.031  
10,7 ± 0,8  
.421 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
10,7 ± 0,8  
.421 ± .031  
19mm  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
10,7 ± 0,8  
.421 ± .031  
0.1 Amp  
250 VAC  
F roller lever  
18,00mm  
20  
.7  
1,7  
.060  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
40  
1.4  
3,5  
.123  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
OTHER TERMINATION TYPES ARE AVAILABLE  
For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM10A20A01)  
For PC Straight international, change 2nd set of numbers to 40 (Example: UM10A40A01)  
For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM10A50A01)  
For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM10A60A01)  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control  
13  
Basic Switches  
UM Series  
Subminiature  
ORDER GUIDE 3 AND 5 AMP TYPE SILVER CONTACTS  
O.F. max.  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P  
mm  
inches  
Actuator  
grams  
g
mm  
mm  
mm  
Rating  
Length  
oz.  
ounces  
inches  
inches  
inches  
3 Amp  
250 VAC  
A pin plunger  
50  
1.76  
7,5  
.265  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
100  
3.527  
15,0  
.529  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
3 Amp  
250 VAC  
B flat lever  
18mm  
20  
.7  
1,7  
.060  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
40  
1.4  
3,5  
.123  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
C flat lever  
20mm  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
D flat lever  
26mm  
12  
.4  
1,2  
.042  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
25  
.88  
2,5  
.088  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
J flat lever  
60mm  
6
.2  
0,5  
.018  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
15  
.52  
1,0  
.035  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
3 Amp  
250 VAC  
E simulated  
roller lever, radius  
2,5mm  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
19mm  
H simulated  
roller lever, radius  
1,3mm  
16  
.56  
1,5  
.053  
2,8  
.110  
1,2  
.047  
0,8  
.021  
10,7 ± 0,8  
.421 ± .031  
35  
1.23  
3,0  
.106  
2,8  
.110  
1,2  
.047  
0,8  
.031  
10,7 ± 0,8  
.421 ± .031  
19,15mm  
F roller lever  
18mm  
20  
.7  
1,7  
.060  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
40  
1.4  
3,5  
.123  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
5 Amp  
250 VAC  
A pin plunger  
150  
5.3  
20  
.705  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
B flat lever  
18mm  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
C flat lever  
20mm  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
D flat lever  
26mm  
45  
1.6  
3,0  
.106  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
J flat lever  
60mm  
1,0  
.035  
8,5  
.335  
2,2  
.087  
2,5  
.098  
8,8 ± 2,4  
.346 ± .094  
E simulated  
roller lever, radius  
2,5mm  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
19mm  
H simulated  
roller lever, radius  
1,3mm  
55  
2
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
10,7 ± 0,8  
.421 ± .031  
19mm  
F roller lever  
18mm  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,50 ± 0,8  
.571 ± .031  
OTHER TERMINATION TYPES ARE AVAILABLE  
For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM40B20A01)  
For PC Straight international, change 2nd set of numbers to 40 (Example: UM40B40A01)  
For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM40B50A01)  
For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM40B60A01)  
14 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
UM Series  
Subminiature  
mm  
in.  
MOUNTING DIMENSIONS (for reference only)  
Pin Plunger Type A  
Solder Cros s -line Terminals – Type 10  
PC Straight Cros s -Line Type 20  
PC Straight In-line – Type 40  
PC Right Angle In-line – Type 50  
PC Left Angle In-line – Type 60  
QC Quick Connect – Type 70  
Lever Actuators 4mm (.158) wide  
18mm Flat Lever Type B  
20mm Flat Lever Type C  
26mm Flat Lever Type D  
60mm Type J  
19mm Simulated Roller Type E/H  
18mm Roller Lever Type F  
Type H has 1,3mm radius  
Type E has 2,5mm radius  
5mm (.197 in.) dia. x 3,2mm (.126 in.)  
thick roller  
Mounting s crew s ize is m 2,3.  
Maximum tightening torque is 3 kg-cm.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 15  
Basic Switches  
UM Series  
Sealed Subminiature  
IP50-SEALED  
IP67-SEALED  
FEATURES  
ELECTRICAL RATINGS (in amps )  
ɀ
ɀ
Silver or gold contacts  
Silver Contacts  
Gold Contacts  
Res is tive  
Variety of integral actuator styles including pin  
plunger, flat lever, roller lever, and simulated  
roller lever  
Voltage  
Res is tive  
Inductive  
125 VAC  
250 VAC  
30 VDC  
2.0  
2.0  
2.0  
0.4  
2.0  
2.0  
2.0  
0.05  
0.1A  
0.1A  
0.1A  
ɀ
ɀ
IP50 or IP67 type sealing  
Choice of quick-connect, printed circuit board,  
solder or leadwire termination  
Form C single-pole double-throw  
Temperature range: 40° to 85°C (40° to  
185°F)  
125 VDC  
UL File No. E12252, CSA File LR23413M167  
ɀ
ɀ
ɀ
ɀ
Weight, approx.: .07 oz. (2g.) for IP50-sealed  
switches; and .14 oz. (4g.) for IP67-sealed  
switches, not including leadwires  
UL, CSA, VDE, and SEMKO marking  
designations  
IP50-sealed UM switches are the same size as non-sealed UM switches on  
pages 12-15. There is an elastomer seal on the switch plunger and a cover-to-  
case seal. They provide a degree of protection against the entry of dust.  
IP67-sealed UM switches have the plunger seal and cover-to-case seal. In  
addition, their AWG # 20 leadwires are molded in epoxy resin. They provide a  
degree of protection against water entry during temporary immersion.  
16 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
UM Series  
IP50-Sealed Subminiature  
C
NO  
NC  
ORDER GUIDE IP50 SEALED 0.1-AMP GOLD CONTACTS  
O.F. max.  
R.F. min.  
grams  
P.T. max.  
mm  
O.T. min.  
mm  
D.T. max.  
mm  
O.P  
mm  
grams  
Actuators  
oz.  
ounces  
inches  
inches  
inches  
inches  
A
B
C
D
E
F
pin plunger  
150  
5.3  
20  
.705  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
flat lever  
flat lever  
flat lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
45  
1.6  
3,0  
.106  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
simulated  
roller lever  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
roller  
lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,5 ± 0,8  
.571 ± .031  
ORDER GUIDE IP50 SEALED 2.0-AMP SILVER CONTACTS  
O.F. max.  
R.F. min.  
grams  
P.T. max.  
mm  
O.T. min.  
mm  
D.T. max.  
mm  
O.P  
mm  
grams  
Actuators  
oz.  
ounces  
inches  
inches  
inches  
inches  
A
B
C
D
E
F
pin plunger  
150  
5.3  
20  
.705  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
flat lever  
flat lever  
flat lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
45  
1.6  
3,0  
.106  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
simulated  
roller lever  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
roller  
lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,5 ± 0,8  
.571 ± .031  
TO SPECIFY PC TERMINALS:  
In the order guides above, change the 2nd set of numbers to 21. Example: UM10E11AS1 converts to UM10E21AS1 with PC terminals  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 17  
Basic Switches  
UM Series  
IP67-Sealed Subminiature  
C
NO  
NC  
ORDER GUIDE IP67 SEALED 0.1-AMP GOLD AND 2.0-AMP SILVER CONTACTS  
O.F. max.  
grams  
oz.  
R.F. min.  
grams  
ounces  
P.T. max.  
mm  
inches  
O.T. min.  
mm  
inches  
D.T. max.  
mm  
inches  
O.P  
mm  
inches  
Actuators  
A
B
C
D
E
F
pin plunger  
150  
5.3  
20  
.705  
0,6  
.024  
0,4  
.016  
0,1  
.004  
8,4 ± 0,3  
.331 ± .012  
flat lever  
flat lever  
flat lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
8,8 ± 0,8  
.346 ± .031  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
8,8 ± 0,8  
.346 ± .031  
45  
1.6  
3,0  
.106  
3,5  
.138  
1,6  
.063  
1,0  
.039  
8,8 ± 1,2  
.346 ± .047  
simulated  
roller lever  
55  
1.9  
3,5  
.123  
2,8  
.110  
1,2  
.047  
0,8  
.031  
11,65 ± 0,8  
.459 ± .031  
roller  
lever  
60  
2.1  
4,0  
.141  
2,5  
.098  
0,8  
.031  
0,5  
.020  
14,5 ± 0,8  
.571 ± .031  
MOUNTING DIMENSIONS  
(For reference only)  
Mounting screw size is m 2,3  
Maximum torque is 3 kg/cm.  
mm  
in.  
Pin Plunger Type A  
PC Terminals  
Solder In-line Terminals  
18 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
UM Series  
IP50-Sealed Subminiature  
MOUNTING DIMENSIONS  
(For reference only)  
Mounting screw size is m 2,3  
Maximum torque is 3 kg/cm.  
mm  
in.  
Pin Plunger Type A  
QC In-line Terminals  
Leadwires  
Lever Actuators 4 mm/.158 in. wide  
18 mm Flat Lever Type B  
19 mm Simulated Roller Lever Type E  
2,5 mm radius  
20 mm Flat Lever Type C  
18 mm Roller Lever Type F  
5 mm/.197 in. dia. x 3,2 mm/.126 in.  
Thick Roller  
26 mm Flat Lever Type D  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 19  
Basic Switches  
SX Series  
Subminiature  
CUT-A-WAY 1SX SUBMINIATURE BASIC SWITCH  
FEATURES  
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
Low operating force to 3 oz. (85 grams)  
maximum  
Sensitive differential travel as low as  
.001 inch maximum  
Power load switching capability up to 7  
amperessilver contacts  
Optional gold contacts for low energy  
applications  
Optional bifurcated gold contacts for  
maximum reliability  
Long mechanical life up to 10,000,000  
cycles95% survival for 11SX series  
1,000,000 cycles95% survival for1SX  
series  
ɀ
Temperature tolerance 65° to  
+250°F (54 to 121°C) on standard  
construction  
GENERAL INFORMATION  
AVAILABLE TERMINALS  
SX subminiature basic switches are small  
size precision snap-action switches from  
MICRO SWITCH. These switches are ide-  
al where savings in space and weight are  
important. Unless otherwise noted, all  
listings have silver contacts.  
ɀ
ɀ
High temperature designs for up to  
+400°F (204°C) for 100 hours  
Variety of integral and auxiliary  
actuators  
SX switches are available with several  
types of terminations. The T and T2 termi-  
nals provide easy solder lead wire attach-  
ment. The H58 terminal offers the simplic-  
ity of quick-connect and mate with AMP  
.058-inch receptacles. Pin terminals allow  
easy attachment to printed circuit boards.  
ɀ
ɀ
Choice of several terminal styles  
MIL-S-8805  
available  
qualified  
products  
ɀ
UL recognized File # E12252, CSA cer-  
tified file # LR41372  
T
T2  
Mounting torque Round  
head 2-56 UNC 438  
screws—  
2 inch pounds max.  
H391, H392  
H58  
STRAIGHT PIN  
90° FORMED PIN  
Mate with Amp Inc. Part No.  
640024-1 Std.  
Dimensions shown are for reference only  
This section covers only 40 of our most popular SX Series catalog listings. If you dont find what youre looking for, it’s  
likely one of the approximately 200 other active SX listings will meet your needs. Contact the 800 number.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 21  
Basic Switches  
SX Series  
Subminiature  
ORDER GUIDE by as cending electrical capability  
PIN PLUNGER  
Electrical  
Data and O.F. max. R.F. min. P.T. max. O.T. min. D.T. max. O.P.*  
UL Code newtons newtons  
mm  
inches  
mm  
inches  
mm  
inches  
mm  
inches  
Recommended for  
Logic level loads  
5VDC, 2mA; SPNO  
Page 20  
ounces  
ounces  
At  
Left  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,1  
.004  
8,13  
.320  
Best reliability  
(Bifurcated gold contacts)  
.010 Amp 0,7 to 1.39  
0,28  
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.320  
H
2.5 to 5  
1
Applications requiring gold  
contacts (1SX type)  
1 Amp  
1,39  
0,28  
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
D
5
1
Best reliability with  
1 Amp  
1,39  
0,28  
0,51  
0,1  
0,076  
8,13  
higher current rating  
(Bifurcated gold contacts)  
D
5
1
.020  
.004  
.003  
.320  
Lowest differential travel  
1 Amp  
1,39  
0,28  
0,51  
0,1  
0,025  
8,13  
with bifurcated gold contacts  
H
5
1
.020  
.004  
.001  
.320  
Applications requiring gold  
contacts. 11SX type.  
1 Amp  
D
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.320  
MIL-S-8805 applications  
requiring gold contacts  
+180°F (82°C) max. use  
1 Amp  
D
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
As above, with  
T2 terminals  
1 Amp  
D
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
.156wide, with gold  
1 Amp  
1,39  
0,28  
0,51  
0,1  
0,13  
8,13  
contacts +180°F (82°C)  
D
5
1
.020  
.004  
.005  
.320  
+400°F (204°C)  
for 100 hours  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.220  
G
L
+400°F (204°C)  
for 100 hours  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.220  
Dim. Dwg. Fig. 1  
(Except Fig. 2  
for 91SX39-T  
Lowest differential travel  
Most applications  
3 Amps  
0,97  
3.5  
0,21  
0.75  
0,51  
.020  
0,1  
.004  
0,025  
.001  
8,13  
.320  
E
and 93SX34-T)  
5 Amps 0,7 to 1,39  
0,28  
1
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.320  
A
2.5 to 5  
For use in sealed  
enclosures.  
5 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,076  
.003  
8,13  
.320  
A
Best stability under varying  
humidity. 11SX type.  
5 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.320  
A
Up to 7 amps load handling  
Low differential travel  
Added overtravel  
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
B
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,051  
.002  
8,13  
.320  
C
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,25  
.010  
0,13  
.005  
8,13  
.320  
B
Lower force  
7 Amps  
0,83  
0,28  
0,51  
0,1  
0,13  
8,13  
B
3
1
.020  
.004  
.005  
.320  
Operating in temperature  
to +400°F (204°C)  
for 100 hours  
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
I
Best stability under varying  
humidity (1SX type)  
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
B
MIL-S-8805 application  
7 Amps  
1,39  
0,28  
0,51  
0,1  
0,13  
8,13  
requirements +180°F (82°C)  
F
5
1
.020  
.004  
.005  
.320  
MIL-S-8805 application  
7 Amps  
1,39  
0,28  
0,51  
0,1  
0,13  
8,13  
requirements +180°F (82°C)  
F
5
1
.020  
.004  
.005  
.320  
.156wide version  
of standard SX +180°F  
(82°C)  
7 Amps  
1,39  
5
0,28  
1
0,51  
.020  
0,1  
.004  
0,13  
.005  
8,13  
.320  
F
*±0,38 mm  
±.015 in.  
22 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
SX Series  
Subminiature  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. –  
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating  
Position  
ORDER GUIDE  
INTEGRAL LEVERS  
Electrical  
Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
UL Code newtons newtons  
mm  
mm  
mm  
Des cription  
Page 20  
ounces ounces  
inches  
inches  
inches  
inches  
.135 inch (3,43 mm)  
straight lever  
5 Amps  
0,49  
1.76  
0,09  
.32  
1,65  
.065  
0,36  
.014  
0,51  
.020  
8,43±1,14  
.332±.045  
A
As above with gold  
contacts  
1 Amp  
D
0,49  
1.76  
0,09  
.32  
1,65  
.065  
0,36  
.014  
0,51  
.020  
8,43±1,14  
.332±.045  
Dim. Dwg. Fig. 3  
.505 inch (12,8 mm)  
straight lever  
5 Amps  
0,31  
1.1  
0,05  
.18  
2,92  
.115  
0,64  
.025  
0,89  
.035  
8,26±1,91  
.325±.075  
A
As above with gold  
contacts  
1 Amp  
D
0,31  
1.1  
0,05  
.18  
2,92  
.115  
0,64  
.025  
0,89  
.035  
8,26±1,91  
.325±.075  
Dim. Dwg. Fig. 3  
Dim. Dwg. Fig. 4  
Dim. Dwg. Fig. 5  
Dim. Dwg. Fig. 6  
.965 inch (24,5 mm)  
straight lever  
5 Amps  
0,20  
.71  
0,03  
.11  
4,70  
.185  
0,61  
.024  
1,52  
.060  
7,75±2,92  
.305±.115  
A
As above with gold  
contacts  
1 Amp  
D
0,20  
.71  
0,03  
.11  
4,70  
.185  
0,61  
.024  
1,52  
.060  
7,75±2,92  
.305±.115  
.042 inch (1,1 mm)  
simulated roller lever  
5 Amps  
0,58  
2.1  
0,11  
.39  
1,27  
.050  
0,25  
.010  
0,38  
.015  
14,15±0,91  
.557±.036  
A
As above with gold  
contacts  
1 Amp  
D
0,58  
2.1  
0,11  
.39  
1,27  
.050  
0,25  
.010  
0,38  
.015  
14,15±0,91  
.557±.036  
.459 inch (11,7 mm)  
simulated roller lever  
5 Amps  
0,31  
1.1  
0,05  
.18  
2,67  
.105  
0,56  
.022  
0,89  
.035  
14,86±1,65  
.585±.065  
A
As above, with gold  
contacts  
1 Amp  
D
0,31  
1.1  
0,05  
.18  
2,67  
.105  
0,56  
.022  
0,89  
.035  
14,86±1,65  
.585±.065  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 23  
Basic Switches  
SX  
Subminiature  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. –  
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating  
Position; F.P. – Free Position.  
*All characteristics are taken with actuator assembled on Catalog Listing 1SX1-T as shown.  
ORDER GUIDE  
AUXILIARY  
ACTUATORS  
Actuator  
Length  
‘‘A’’  
mm  
inches  
Switches are not  
included with  
actuators.  
O.F. max. R.F. min.  
newtons newtons  
ounces ounces  
P.T.  
mm  
inches  
O.T.  
mm  
inches  
D.T. max.  
mm  
inches  
O.P.††  
mm  
inches  
F.P.  
mm  
inches  
Des cription  
Straight lever  
18.3  
.72  
0,28  
1
0,04  
.14  
0,76  
.030  
0,76  
.030  
10,8  
.425  
12,3  
.485  
approx.  
approx.  
approx.  
approx.  
approx.  
Straight lever  
(For higher temp.)  
18,3  
.72  
0,28  
1
0,04  
.14  
0,76  
.030  
0,76  
.030  
10,8  
.425  
12,3  
.485  
Dim. Dwg. Fig. 7  
approx.  
approx.  
approx.  
approx.  
Roller lever  
16,5  
.65  
0,42  
1.5  
0,04  
1.4  
0,51  
.020  
0,76  
.030  
14,91,14  
.585.045  
168  
.660  
max.  
Roller lever  
(For higher temp.)  
16,5  
.65  
0,42  
1.5  
0,04  
.14  
0,51  
.020  
0,76  
.030  
14,91,14  
.585.045  
16,8  
.660  
max.  
Dim. Dwg. Fig. 8  
Straight leaf  
9,4  
.37†  
1,95  
7
0,56  
2
.225  
approx.  
0,38  
.015  
0,64  
.025  
7,5  
.295  
12,3  
.485  
ref.  
Straight leaf  
(For higher temp.)  
9,4  
.37†  
1,95  
7
0,56  
2
.225  
approx.  
0,38  
.015  
0,64  
.025  
7,5  
.295  
12,3  
.485  
ref.  
Reverse leaf  
9,4  
.37†  
1,67  
6
0,28  
1
.110  
approx.  
0,38  
.015  
0,64  
.025  
7,5  
.295  
9,4  
.370  
ref.  
Dim. Dwg. Fig. 9  
Roller leaf  
6,1  
.24†  
1,95  
7
0,28  
1
.225  
approx.  
0,38  
.015  
0,64  
.025  
12,2  
.480  
16,5  
.650  
ref.  
Roller leaf  
(For higher temp.)  
6,1  
.24†  
1,95  
7
0,28  
1
.225  
approx.  
0,38  
.015  
0,64  
.025  
12,2  
.480  
16,5  
.650  
ref.  
Reverse roller leaf  
7,6  
.30†  
1,67  
6
0,56  
2
.110  
approx.  
0,38  
.015  
0,64  
.025  
12,8  
.505  
14,7  
.580  
ref.  
Dim. Dwg. Fig. 9  
Tandem leaf  
7,9  
.31  
4,17  
15  
0,83  
3
.065  
approx.  
0,20  
.008  
0,76  
.030  
7,6  
.300  
9,40  
.370  
ref.  
**Switch is mounted with plunger end reversed  
from JX-40.  
NOTE: Above actuators should be used at tem-  
peratures below +300°F (149°C); except listings  
JX-95, JX-96, JX-219 and JX-220 are for use with  
Except where stated †† ±0,76 mm  
±.030 in.  
Dim. Dwg. Fig. 10  
‘‘A’’ measurement is from center of mounting  
hole nearest tip of lever to the point indicated on the 4SX1-T to 400°F. (204°C).  
drawing.  
24 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
SX Series  
Subminiature  
MOUNTING DIMENSIONS (for reference only)  
PIN PLUNGER  
INTEGRAL LEVERS  
Dim. ‘‘A’’  
311SX1-T 3,6/.14  
311SX2-T 13,0/.51  
Fig. 1  
Fig. 2  
Fig. 3  
INTEGRAL LEVERS  
Interchangeable with 1SX-1T switch with  
JX-25 actuator.  
Fig. 4  
Fig. 5  
Fig. 6  
AUXILIARY ACTUATORS  
Fig. 7  
Fig. 8  
Fig. 9  
Fig. 10  
Switches are not included with actuator.  
Mounting holes accept pins or screws of  
.087 diameter (2,21 mm).  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 25  
Basic Switches  
SM Series  
Subminiature  
CUT-A-WAY SM SUBMINIATURE BASIC SWITCH  
FEATURES  
ɀ
ɀ
ɀ
Low operating force to 2 ounces  
maximum  
Sensitive differential travel as low as  
.001 inch (0,025 mm) maximum  
Power load switching capability  
available to 11 amps (VAC) – silver  
contacts  
ɀ
ɀ
ɀ
ɀ
Motor load handling capacity to 1/4  
hp (VAC)  
Optional gold contacts for low energy  
applications  
Optional bifurcated gold contacts for  
maximum reliability  
Long mechanical life  
– 11SM Series 10,000,000  
operations  
– 1SM/41SM Series 80,000  
operations  
– Bifurcated contacts 1,000,000  
operations  
All at 95% survival  
Standard temperature range 65° to  
AVAILABLE TERMINALS  
GENERAL INFORMATION  
Various terminals are available for most SM subminiature switches are slightly  
listings. These include: the T and T2 for larger than the SX switches. These  
wrap-around soldering of leadwires; sol- switches combine small size and light  
der terminals for solder connections; H58 weight with ample electrical capacity, pre-  
terminals and H4 series terminals provide cision operation and long life. Unless oth-  
easy quick-connect installation; H2 type, erwise noted, all listings have silver con-  
round wire wrap or PC terminals; H6 rect- tacts.  
angular wire wrap terminals are also avail-  
able. Other quick-connect terminals of  
the Series H types are available. Contact  
the 800 number for ordering information.  
ɀ
ɀ
+185°F (54 to 85°C)  
High temperature construction  
available for use to +400°F (204°C)  
for 100 hours  
Variety of integral and auxiliary  
actuators  
Choice of several terminal styles  
Military Standard construction  
available with three listings on the  
MIL-S-8805 qualified products list  
UL recognized File # E12252, CSA  
certified File # LR41372  
ɀ
ɀ
ɀ
T
SOLDER  
T2  
ɀ
Mounting Torque:  
2.3 inch pounds max.  
H4  
H58  
H2  
Mates with Amp Inc. Part  
No. 640024-1 Std.  
Dimensions shown are for reference only  
This section covers only 38 of our most popular SM Series catalog listings. If you dont find what youre looking for, it’s  
likely one of the approximately 500 other active SM listings will meet your needs. Contact the 800 number.  
26 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
SM Series  
Subminiature  
Characteris tics : O.F. — Operating Force; R.F. — Release  
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. —  
Differential Travel; O.P. — Operating Position.  
ORDER GUIDE by as cending electrical capability  
PIN PLUNGERS  
Electrical  
Data And  
O.F.  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.*  
mm  
UL Code newtons newtons  
mm  
mm  
mm  
Recommended For  
Page 20 ounces ounces inches  
inches  
inches  
inches  
Gold alloy contacts  
.1 Amp 0,83-1,39  
3-5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
P
Bifurcated gold contacts,  
reduced rating  
.1 Amp 0,83-1,39  
3-5  
0,28  
1
0,51  
.020  
0,076  
.003  
0,1  
.004  
8,38  
.330  
P
Application requiring gold  
contacts  
1 Amp 0,83-1,39  
3-5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
N
Best reliability  
1 Amp 0,83-1,39  
0,28  
0,51  
0,076  
0,1  
8,38  
(Bifurcated gold contacts)  
N
3-5  
1
.020  
.003  
.004  
.330  
Lower force  
4 Amps  
0,56  
2
0,14  
.5  
0,51  
.020  
0,13  
.005  
0,051  
.002  
8,38  
.330  
S
Most applications  
5 Amps 0,83-1,39  
3-5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
J
Operating in temperatures 5 Amps 0,83-1,39  
to +250°F (121°C) 3-5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
J
Dim. Dwg. Fig. 1  
Operating in temperatures 5 Amps 0,83-1,39  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
to +400°F (204°C) 100 hrs.  
*
3-5  
Less differential travel  
5 Amps  
0,97  
3.5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,025  
.001  
8,38  
.330  
K
max.  
MIL-S-8805 application  
requirements  
5 Amps 0,83-1,39  
3-5  
0,28  
1
0,76  
.030  
0,13  
.005  
0,1  
.004  
8,38  
.330  
R
requirements,  
MIL-S-8805 application  
5 Amps 0,83-1,39  
3-5  
0,28  
1
0,76  
.030  
0,13  
.005  
0,1  
.004  
8,38  
.330  
R
solder terminals  
Best stability under  
varying humidity  
5 Amps 0,83-1,39  
3-5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
J
Up to 11 ampere 1/4 hp  
(AC) load handling  
11 Amps 0,83-1,39  
3-5  
0,28  
1
0,76  
.030  
0,13  
.005  
0,1  
.004  
8,38  
.330  
M
*For electrical data call 1-800-537-6945  
Sealed plunger  
construction  
5 Amps 0,83-2,09  
3-7.5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
K
As above with gold  
contacts  
1 Amp 0,83-2,09  
3-7.5  
0,28  
1
0,51  
.020  
0,13  
.005  
0,1  
.004  
8,38  
.330  
N
Except where stated * ±0,38mm  
±.015 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 27  
Basic Switches  
SM Series  
Subminiature  
Characteris tics : O.F. — Operating Force; R.F. — Release  
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential  
Travel; O.P. — Operating Position.  
ORDER GUIDE  
INTEGRAL LEVERS  
Electrical  
Data And O.F. max. R.F. max. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
inches  
UL Code newtons newtons  
mm  
inches  
mm  
inches  
mm  
inches  
Des cription  
Page 20 ounces  
ounces  
.285 inch (7,24mm)  
straight lever  
5 Amps  
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,51  
.020  
0,48  
.019  
8,64±1,5  
.340±.060  
J
As above with gold  
contacts  
1 Amp  
N
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,51  
.020  
0,48  
.019  
8,64±1,5  
.340±.060  
Dim. Dwg. Fig. 4  
.285 inch (7,24mm)  
straight lever.  
4 Amps  
0,16  
.57  
0,03  
.11  
2,16  
.085  
0,51  
.020  
0,36  
.014  
8,64±1,5  
.340±.060  
S
Lower force  
.565 inch (14,35mm)  
straight lever  
5 Amps  
0,31  
1.1  
0,05  
.18  
3,05  
.120  
0,66  
.026  
0,69  
.027  
8,51±2  
.335±.080  
J
As above with gold  
contacts  
1 Amp  
N
0,31  
1.1  
0,05  
.18  
3,05  
.120  
0,66  
.026  
0,69  
.027  
8,51±2  
.335±.080  
Dim. Dwg. Fig. 5  
.565 inch (14,35mm)  
straight lever.  
4 Amps  
0,11  
.4  
0,02  
.07  
3,05  
.120  
0,66  
.026  
0,38  
.015  
8,51±2  
.335±.080  
S
Lower force  
1.765 inch (44,8mm)  
straight lever  
5 Amps  
0,15  
.53  
0,02  
.07  
7,87  
.310  
1,45  
.057  
2,8  
.110  
7,11±4,3  
.280±.170  
J
Dim. Dwg. Fig. 6  
As above with gold  
1 Amp  
0,15  
0,02  
7,87  
1,45  
2,8  
7,11±4,3  
contacts  
N
.53  
.07  
.310  
.057  
.110  
.280±.170  
1.765 inch (44,8mm)  
straight lever.  
4 Amps  
0,06  
.2  
0,01  
.04  
7,87  
.310  
1,45  
.057  
1,78  
.070  
7,11±4,3  
.280±170  
S
Lower force  
.251 inch (6,38mm)  
simulated roller lever  
5 Amps  
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,46  
.018  
0,48  
.019  
11,7±1,5  
.460±.060  
J
As above with gold  
contacts  
1 Amp  
N
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,46  
.018  
0,48  
.019  
11,7±1,5  
.460±.060  
.251 inch (6,38mm)  
simulated roller lever.  
Lower force  
4 Amps  
0,16  
.57  
0,03  
.11  
2,16  
.085  
0,46  
.018  
0,33  
.013  
11,7±1,5  
.460±.060  
Dim. Dwg. Fig. 7  
S
.535 inch (13,6mm)  
simulated roller lever  
5 Amps  
0,31  
1.1  
0,05  
.18  
3,05  
.120  
0,66  
.026  
0,69  
.027  
11,56±2  
.455±.080  
J
.535 inch (13,6mm)  
simulated roller lever.  
Lower force  
4 Amps  
0,11  
.4  
0,02  
.07  
3,05  
.120  
0,66  
.026  
0,38  
.015  
11,56±2  
.455±.080  
S
Dim. Dwg. Fig. 8  
.251 inch (6,38mm)  
roller lever  
5 Amps  
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,46  
.018  
0,48  
.019  
14,2±1,5  
.560±.060  
J
As above with gold  
contacts  
1 Amp  
N
0,39  
1.4  
0,07  
.25  
2,16  
.085  
0,46  
.018  
0,48  
.019  
14,2±1,5  
.560±.060  
Dim. Dwg. Fig. 9  
.251 inch (6,38mm)  
roller lever.  
4 Amps  
0,16  
.57  
0,03  
.11  
2,16  
.085  
0,46  
.018  
0,33  
.013  
14,2±1,5  
.560±.060  
S
Lower force  
.535 inch (13,6mm)  
roller lever  
5 Amps  
0,31  
1.1  
0,05  
.18  
3,05  
.120  
0,66  
.026  
0,69  
.027  
14,1±2  
.555±.080  
J
Dim. Dwg. Fig. 10  
28 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
SM Series  
Subminiature  
ORDER GUIDE  
INTEGRAL LEAF  
Electrical  
Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
inches  
UL Code newtons newtons  
mm  
inches  
mm  
inches  
mm  
inches  
Recommended For  
Page 20 ounces  
ounces  
Force and stability of  
flexible leaf actuator  
5 Amps  
1,95  
7
0,56  
2
5,54  
.218  
0,76  
.030  
0,76  
.030  
8,89±0,76  
.350±.030  
J
As above with gold  
contacts  
1 Amp  
N
1,95  
7
0,56  
2
5,54  
.218  
0,76  
.030  
0,76  
.030  
8,89±0,76  
.350±.030  
Dim. Dwg. Fig. 11  
Flexible leaf with roller  
5 Amps  
1,95  
7
0,56  
2
5,56  
.219  
0,76  
.030  
0,64  
.025  
14,3±0,76  
.562±.030  
J
As above with gold  
contacts  
1 Amp  
N
1,95  
7
0,56  
2
5,56  
.219  
0,76  
.030  
0,64  
.025  
14,3±0,76  
.562±.030  
Dim. Dwg. Fig. 12  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 29  
Basic Switches  
SM Series  
Subminiature  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P.  
— Operating Position; F.P. — Free Position  
* All characteristics are taken with actuator assembled to Catalog Listing 11SM3-T as  
shown.  
AUXILIARY  
ACTUATORS  
ORDER GUIDE  
Switches are not  
included with the  
actuators.  
Actuator  
Length  
‘‘A’’  
mm  
inches  
O.F. max. R.F. min.  
newtons newtons  
ounces ounces  
P.T. max.  
mm  
inches  
O.T. min. D.T. max.  
O.P.  
mm  
inches  
F.P. max.  
mm  
inches  
mm  
mm  
Des cription  
inches  
inches  
Straight leaf  
16,8  
.66  
2,78  
10  
0,56  
2
1,98  
.078  
0,38  
.015  
0,38  
.015  
8,89±0,38  
.350±.015  
11,3  
.445  
Dim. Dwg. Fig. 14  
Roller leaf  
(Bronze roller)  
15  
.59  
2,78  
10  
0,83  
3
1,98  
.078  
0,38  
.015  
0,38  
.015  
14,2±0,38  
.580±.015  
16,9  
.665  
Dim. Dwg. Fig. 14  
Formed leaf  
(Simulated  
roller)  
14,7  
.58  
2,78  
10  
0,56  
2
2,39  
.094  
0,79  
.031  
0,38  
.015  
9,65±0,38  
.380±.015  
12,1  
.475  
Dim. Dwg. Fig. 14  
Straight lever  
26,2†  
1.03  
0,28  
1
0,04  
.14  
3,18  
.125 approx.  
0,76  
.030  
0,76  
.030  
10,3  
.406 approx.  
Dim. Dwg. Fig. 16  
Roller lever  
(Steel roller)  
25,4†  
1.00  
0,28  
1
0,04  
.14  
3,18  
.125 approx.  
0,76  
.030  
0,76  
.030  
14,3  
.562 approx.  
Dim. Dwg. Fig. 16  
Formed lever  
(Simulated  
roller)  
25,4†  
1.00  
0,28  
1
0,04  
.14  
3,18  
.125 approx.  
0,76  
.030  
0,76  
.030  
11,6  
.455 approx.  
Dim. Dwg. Fig. 16  
Tandem leaf  
5,3  
.21  
5,00  
18  
2,78  
10  
2,36  
.093  
0,15  
.006  
0,38  
.015  
8,89±0,38  
.350±.015  
10,5  
.415  
Tandem  
roller leaf  
4,3  
.17  
11,1  
40  
4,45  
16  
2,36  
.093  
0,13  
.005  
0,38  
.015  
14,5±0,38  
.570±.015  
16,1  
.635  
(Bronze roller)  
**Travel characteristics on tandem actuators vary with actual basic switch characteristics.  
NOTE: Above actuators should be used below +300°F.  
See page 79 for other actuators that may be used with SM Switches at higher temperatures.  
‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing.  
30 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
SM Series  
Subminiature  
MOUNTING DIMENSIONS (for reference only)  
PIN PLUNGER  
Fig. 1  
Fig. 2  
INTEGRAL LEVERS  
Fig. 4  
Fig. 5  
Fig. 6  
Fig. 7  
Fig. 8  
Fig. 9  
Fig. 10  
INTEGRAL LEAFS  
Mounting holes accept pins or screws of  
.087 inch (2,21 mm) max. diameter  
Fig. 11  
Fig. 12  
AUXILIARY ACTUATORS  
Fig. 14  
Fig. 16  
Switches are not included with the actuators.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 31  
Position Sensors  
SE and XE Series  
Environment-Sealed Basic Switches  
GENERAL INFORMATION  
FEATURES  
SE and XE switches are the smallest envi-  
ronment-sealed switches offered by  
MICRO SWITCH. Both types enclose ba-  
sic switches within a corrosion resistant  
aluminum housing to seal precision  
switch contacts from contamination. SE  
switches include a SM basic switch, and  
XE switches include the smaller SX basic  
switch.  
ɀ
ɀ
ɀ
ɀ
Watertight seal per enclosure design  
symbol 3, MIL-S-8805  
Power load switching capability up to 7  
amps  
Temperature tolerance up to +221°F  
(105°C)  
High temperature construction for use  
to +300°F (149°C)  
Several auxiliary actuators  
Choice of termination  
Military standard construction with list-  
ings qualified to MIL-S-8805  
All 4SE switches are UL recognized  
and CSA certified  
ɀ
ɀ
ɀ
Switches held depressed for extended  
periods of time at temperature extremes  
may experience retarded plunger return  
upon deactuation. Where such a condi-  
tion exists in the application, contact the  
800 number for special designs that are  
available.  
ɀ
ɀ
4XE switches are UL recognized  
ELECTRICAL RATINGS  
Circuitry  
Electrical Rating Code  
Single-Pole  
Double-Throw  
A
5 amps res., 3 amps ind., (sea level), 5 amps res.,  
2.5 amps ind., (50,000 feet) 28 vdc.  
D
UL Rating  
7 amps, 250 vac 60 Hz  
5 amps res., 5 amps ind., 125 or 250 vac, 60 Hz.  
B
C
UL and CSA Rating  
5 amps, 250 vac, 60 Hz  
E
R
7 amps res., 4 amps ind., (sea level),  
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.  
7 amps res., 4 amps ind., (sea level),  
1 amp res., 0.50 amp ind., 28 vdc.  
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.  
7 amps res., 4 amps ind., (sea level), 115 vac, 400 Hz  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position  
SE SWITCHES ORDER GUIDE  
Characteris tics  
Electrical  
Rating  
Code  
O.F.  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
inches  
Recommended  
For  
Newtons Newtons  
ounces  
mm  
mm  
mm  
ounces  
inches  
inches  
inches  
1 foot leads  
(other lengths  
available)  
Most applications  
A
A
A
B
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
SPST — Normally-  
closed  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
SPST — Normally-  
open  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
UL and CSA listing  
and UL and CSA  
listed lead wire  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
Oil resistant  
Fluorosilicone seal  
A
A
A
A
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
Fig. 1  
Lower force  
1,11-2,22  
0,56  
2
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
4-8  
High return force  
1,39-5,28  
5-19  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
For customer  
leading  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,08  
.003  
0,1  
.004  
10,8  
.425  
Fig. 2  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 13  
Position Sensors  
SE Series  
Environment-Sealed Basic Switches  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position  
AUXILIARY ACTUATORS FOR SE SWITCHES ORDER GUIDE  
(Switches are not included with actuators )  
Characteris tics meas ured  
with actuators mounted to a 1SE1  
Actuator  
Length A  
mm  
O.F.  
max.  
Newtons Newtons  
R.F.  
min.  
P.T.  
approx.  
mm  
O.T.  
min.  
mm  
D.T.  
max.  
mm  
O.P.  
mm  
inches  
F.P.  
mm  
inches  
Des cription  
inches  
ounces ounces  
inches  
inches inches  
Straight leaf  
(mounting  
hardware  
16,8  
.66  
3,34  
12  
0,56  
2
3,81  
.150  
0,38  
.015  
0,64  
.025  
11,2  
.440  
15±0,76  
.590±.030  
included)  
Fig. 3  
Roller leaf.  
Roller turned  
90° to switch  
axis  
16,8  
.66  
3,34  
12  
0,56  
2
3,81  
.150  
0,38  
.015  
0,64  
.025  
16,3  
.640  
20,1  
.790  
approx.  
(mounting  
hardware  
included).  
Fig. 4  
Roller leaf  
(mounting  
hardware  
included)  
14,2  
.560  
3,34  
12  
0,56  
2
3,81  
.150  
0,38  
.015  
0,64  
.025  
16,3  
.640  
20,1±0,76  
.790±.030  
Fig. 5  
Roller leaf.  
Reversed  
position  
14,2  
.560  
3,34  
12  
0,56  
2
3,81  
.150  
0,38  
.015  
0,64  
.025  
16,3  
.640  
20,1±0,76  
.790±.030  
(mounting  
hardware  
included)  
Fig. 6  
Roller lever  
13,7  
.540  
1,67  
6
0,28  
1
2,54  
.100  
0,25  
.010  
0,41  
.016  
16,3  
.640  
18,8±0,76  
.740±.030  
Fig. 7  
Tandem  
Roller  
Lever  
17,8  
.700  
4,73  
17  
1,11  
4
2,54  
.100  
0,15  
.006  
0,3  
16,8±1,3 19,3±1,3  
.012 .660±.050 .760±.050  
Fig. 8  
14 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Position Sensors  
XE Series  
Environment-Sealed Basic Switches  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
XE SWITCHES ORDER GUIDE  
P.T. — Pretravel; D.T. — Differential Travel; O.P. — Operating Position.  
Characteris tics  
O. F.  
max.  
R. F.  
max.  
P. T.  
max.  
mm  
O. T.  
min.  
mm  
D. T.  
max.  
mm  
O. P.  
mm  
inches  
Electrical  
Rating  
Code  
Newtons Newtons  
Recommended For  
ounces  
ounces  
inches  
inches  
inches  
±.020 (0,51)  
1 foot leads  
Most applications  
C
1,39-4,73  
1,11  
1,27  
0,1  
0,13  
10,8  
(other lengths MIL-S-8805  
5-17  
4
.050  
.004  
.005  
.425  
available)  
requirements  
General Use  
C
1,39-4,73  
1,11  
1,27  
0,1  
0,13  
10,8  
MIL-S-8805  
requirements  
5-17  
4
.050  
.004  
.005  
.425  
MIL-W-22759/11  
wire  
SPST-Normally Open  
C
R
D
C
E
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,1  
.004  
0,13  
.005  
10,8  
.425  
Gold Contacts  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,1  
.004  
0,13  
.005  
10,8  
.425  
MIL-W-22759/11 wire  
UL listing and UL and  
CSA listed leadwire  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,1  
.004  
0,13  
.005  
10,8  
.425  
Oil resistant  
Fluorosilicone seal  
1,39-4,73  
5-17  
1,11  
4
1,27  
.050  
0,1  
.004  
0,13  
.005  
10,8  
.425  
Less operating force  
Use to +300°F  
(149°C)  
2,50  
9 max.  
0,56  
2
0,76  
.030  
0,1  
.004  
0,13  
.005  
10,9  
.430  
Fig. 9  
For customer leading  
Use to +300°F  
(149°C)  
E
C
2,50  
9 max.  
0,56  
2
0,76  
.030  
0,1  
.004  
0,13  
.005  
10,9  
.430  
For customer leading  
1,39-4,73  
1,11  
1,27  
0,1  
0,13  
10,8  
Fig. 10  
5-17  
4
.050  
.004  
.005  
.425  
Characteris tics : O.F. — Operating Force; R.F. — Release  
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential  
Travel; O.P. — Operating Position; F.P. — Free Position.  
AUXILIARY ACTUATORS FOR XE SWITCHES ORDER GUIDE  
(Switches are not included with the actuators )  
Characteris tics meas ured with actuator mounted on a 1XE1  
O. F.  
max.  
Newtons  
ounces  
R. F.  
min.  
Newtons  
ounces  
P. T.  
approx.  
mm  
O. T.  
min.  
mm  
D. T.  
max.  
mm  
O.P.  
mm  
inches  
F.P.  
mm  
inches  
Des cription  
inches  
inches  
inches  
Straight leaf  
5,84  
21  
0,83  
3
3,18  
.125  
0,23  
.009  
0,3  
.012  
10,8±0,76  
.425±.030 .550±.030  
14±0,76  
Fig. 11  
Roller leaf  
5,84  
21  
0,83  
3
3,18  
.125  
0,23  
.009  
0,3  
.012  
15,9±0,89 19,1±0,89  
.625±.035 .750±.035  
Fig. 12  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 15  
Position Sensors  
SE Series  
Environment-Sealed Basic Switches  
SE MOUNTING DIMENSIONS (For reference only)  
SE s witches  
MOUNTING HOLES WILL ACCEPT PINS OR  
SCREWS OF 22,1/.087 MAX DIA  
Fig. 1  
Fig. 2  
SE auxiliary actuators  
Fig. 4  
Fig. 5  
Fig. 3  
Fig. 8  
Fig. 6  
Fig. 7  
16 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Position Sensors  
XE Series  
Environment-Sealed Basic Switches  
XE MOUNTING DIMENSIONS (For reference only)  
XE s witches  
Fig. 9  
Fig. 10  
XE auxiliary actuators  
Fig. 11  
Fig. 12  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 17  
Position Sensors  
HS Series  
Hermetically Sealed Switches  
GENERAL INFORMATION  
FEATURES  
HS switches are designed for applications  
where maximum electrical rating and max-  
imum sealing are essential, and where size  
and weight requirements are less critical.  
These switches are side mounted through  
mounting holes that are outside the sealed  
switching chamber.  
ɀ
Hermetically sealed per MIL-S-8805,  
design symbol 5 (–67° to +180°F or  
–55° to 82°C)  
Power load switching capability up to  
25 amperes, 28 VDC  
Temperature tolerance from –67°F to  
+250°F (–55°C to +125°C)  
High temperature construction for use  
to +300°F (149°C)  
Several styles of integral lever  
actuators  
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
Two styles of terminals  
Military standard construction with list-  
ings on the MIL-S-8805 qualified prod-  
ucts list  
ɀ
UL recognized File # E12252; CSA cer-  
tified LR 4442  
ELECTRICAL RATINGS  
Circuitry  
Electrical Rating Codes  
Single-Pole  
M
25 amps res., 8 amps ind., 5 amps motor, 3 amps  
Double-Throw  
lamp load, 28 vdc;  
1 amp res., 1 amp ind., 115 vac, 60 Hz  
UL-CSA Rating: 1 amp., 115 vac, 60 Hz.  
N
O
15 amps res., 8 amps ind., 28 vdc;  
1 amp res., 1 amp ind., 115 vac, 60 Hz  
20 amps res., 8 amps ind., 28 vdc;  
1 amp res., 1 amp ind., 115 vac, 60 Hz  
UL-CSA Rating: 1 amp, 115 vac, 60 Hz  
P
10 amps res., 5 amps ind., 28 vdc;  
1 amp res., 1 amp ind., 115 vac, 60 Hz  
UL-CSA Rating: 1 amp., 115 vac, 60 Hz.  
22 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Position Sensors  
HS Series  
Hermetically Sealed Switches  
Characteris tics : O.F. — Operating Force; R.F. —  
Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T.  
— Differential Travel; O.P. — Operating Position.  
HS ORDER GUIDE  
Operating Characteris tics  
Electrical O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
inches  
Rating  
Code  
Newtons Newtons  
mm  
inches  
mm  
inches  
mm  
inches  
Recommended For  
ounces  
ounces  
Most applications  
MIL-S-8805 (M8805/47)  
M
2,78-6,12  
10-22  
1,11  
4
1,65  
.065  
0,25  
.010  
0,51  
.020  
13,5 ± 0,38  
.530 ± .015  
Operating in  
temperatures to  
+250°F (121°C)  
O
2,78-6,12  
10-22  
1,11  
4
1,65  
.065  
0,25  
.010  
0,51  
.020  
13,5 ± 0,38  
.530 ± .015  
Operating in  
temperatures to  
+300°F (149°C)  
P
2,78-8,34  
10-30  
1,11  
4
1,65  
.065  
0,25  
.010  
0,51  
.020  
13,5 ± 0,38  
.530 ± .015  
Fig. 1  
Lead wire termination  
N
2,78-6,12  
10-22  
1,11  
4
1,65  
.065  
0,25  
.010  
0,51  
.020  
15,6  
.615±  
.020  
Fig. 2  
Fig. 3  
Applications requiring  
added overtravel  
M
M
1,11-5,56  
4-20  
0,56  
2
1,57  
.062 max.  
2,54  
.100  
13,54  
.533  
approx.  
MIL-S-8805  
6,12-7,78  
22-28  
1,11  
4
2,16  
.085  
0,25  
.010  
0,51  
.020  
13,5 ± 0,38  
.530 ± .015  
requirements. More  
operating force  
Fig. 4  
Fig. 5  
Roller lever  
M
2,78-6,12  
10-22  
1,11  
4
1,65  
.065  
0,25  
.010  
0,51  
.020  
18,3 ± 0,38  
.720 ± .015  
HS MOUNTING DIMENSIONS (For reference only)  
Mounting holes will accept pins or s crews of .139(3,53mm) diameter.  
Fig. 1  
Fig. 2  
Fig. 3  
Fig. 4  
Fig. 5  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 23  
Position Sensors  
HM Series  
Miniature Hermetically Sealed Switches  
GENERAL INFORMATION  
FEATURES  
HM switches are not generally recom-  
mended for 115 VAC, 60 Hz. If you have a  
60 Hz application in the milliamp range,  
contact our 800 number for special de-  
sign variations that are available.  
ɀ
Hermetically sealed per enclosure de-  
sign symbol 5, MIL-S-8805  
Power load switching capability up to 4  
amperes, 28 VDC and 2 Amps 115 VAC,  
400 Hz  
ɀ
ɀ
ɀ
Temperature tolerance from –85°F to  
+250°F (–65°C to +121°C)  
High temperature construction for use  
from –85°F to +500°F (–65°C to  
+260°C)  
ɀ
ɀ
ɀ
ɀ
Variety of auxiliary actuators  
Choice of terminal styles  
Gold contacts for special applications  
Military standard construction with list-  
ings on the MIL-S-8805 qualified prod-  
ucts list.  
ELECTRICAL RATINGS  
Circuitry  
Electrical Rating Code  
Single-Pole  
Double-Throw  
H
I
1 amp res., 0.25 amp ind., 28 VDC.  
Single-Pole  
Double-Throw  
2 amps res., 2 amps ind., 0.5 amps lamp load, 115 VAC,  
400 Hz.  
4 amps res., 2 amps ind., 1 amp lamp load, 28 VDC  
1
Single-Pole  
J
2  
amp res., 1⁄  
amp ind. (sea level or 70,000 ft.),  
4
Double-Throw  
28 VDC  
Single-Pole  
Double-Throw  
K
L
3 amps res., 1 amp ind. (sea level or 70,000 ft.), 28 VDC  
1 amp res. or ind. (sea level), 115 VAC., 400 Hz.  
Single-Pole  
3 amp res., 1 amp ind., 28 VDC  
Double-Throw  
1 amp res., 1 amp ind., 115 VAC, 400 Hz.  
APPLICATION NOTES  
1. Honeywelldoes not recommend the use ofsilver cadmium oxide switch con-  
tacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5  
amp. Catalog listings in the 5, 6, 15, and 16HM Series use silver cadmium oxide contacts. If you  
have specific questions, contact the MICRO SWITCH Application Center at 1-800-537-6945.  
2. For applications involving non-arcing loads, catalog listings in the 9, 10, 19 and 20HM Series  
are recommended.  
3. The 1, 2, 5, and 6HM Series are recommended for use only in 3 to 4 amp range applications.  
18 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Position Sensors  
HM Series  
Miniature Hermetically Sealed Switches  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position.  
HM ORDER GUIDE  
Operating Characteris tics  
O.P.  
mm  
Electrical O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
Rating  
Code  
Newtons Newtons  
mm  
inches  
mm  
inches  
mm  
inches  
Recommended For  
ounces  
ounces  
inches ±.015 (0,38 mm)  
Most applications.  
K
1,95  
0,28  
0,76  
0,08  
0,15  
8,38  
Exceeds MIL-S-8805  
requirements for  
7
1
.030  
.003  
.006  
.330  
shock and vibration.  
Applications requiring  
gold contacts  
H
1,95  
7
0,28  
1
0,76  
.030  
0,08  
.003  
0,15  
.006  
8,38  
.330  
Fig. 1  
Bifurcated gold  
J
I
1,95  
7
0,28  
1
0,76  
.030  
0,08  
.003  
0,15  
.006  
8,38  
.330  
contacts  
MIL-S-8805  
1,95  
0,28  
0,76  
0,08  
0,15  
8,38  
application  
7
1
.030  
.003  
.006  
.330  
requirements 1 ft.  
(305mm) leads  
5 foot (1524mm) long  
I
1,95  
0,28  
0,76  
0,08  
0,15  
8,38  
leads  
7
1
.030  
.003  
.006  
.330  
Fig. 2  
High temperature to  
L
1,95  
0,28  
0,76  
0,08  
0,15  
8,38  
500°F (260°C) flat  
7
1
.030  
.003  
.006  
.330  
spring  
Fig. 3  
Operating in  
L
1,95  
0,28  
0,76  
0,08  
0,15  
8,38  
temperatures to  
7
1
.030  
.003  
.006  
.330  
+500°F (260°C) with  
weld tab termination.  
Fig. 4  
HM MOUNTING  
A force spreading plate is recommended to reduce the  
chance of product damage due to excessive mounting force.  
MOUNTING PLATE  
NOTICE  
Torque on # 2 mounting screws must be restricted to 1.5 inch  
pounds max. to prevent switch damage. The force spreading  
mounting plate used as shown will allow up to 2.5 inch  
pounds of mounting torque.  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 19  
Position Sensors  
HM Series  
Miniature Hermetically Sealed Switches  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position; F.P. — Free Position.  
AUXILIARY ACTUATORS FOR HM SWITCHES ORDER GUIDE  
(Switches are not included)  
Operating Characteris tics with Actuator Mounted on a 6HM1-1  
O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
F.P.  
mm  
Temp. Newtons Newtons  
mm  
mm  
mm  
Des cription (Max.)  
ounces  
ounces  
inches  
inches  
inches  
inches  
inches  
Leaf  
500°F  
2,50  
0,56  
0,76  
0,76  
8,64  
12,2  
(260°C)  
9
2
.030  
.030  
.340 approx. .480 approx.  
Fig. 5  
Fig. 6  
Fig. 7  
Roller leaf  
500°F  
(260°C)  
2,50  
9
0,56  
2
0,76  
.030  
0,76  
.030  
14  
17,5  
.550 approx. .690 approx.  
Straight lever 500°F  
(260°C)  
0,42  
1.5  
0,03  
.11  
3,18  
.125  
approx.  
0,64  
.025  
1,42  
.056  
10,3  
.406 approx.  
Roller lever  
500°F  
(260°C)  
0,42  
1.5  
0,03  
.11  
3,18  
.125  
0,64  
.025  
1,42  
.056  
14,3  
.562 approx.  
approx.  
Fig. 8  
MOUNTING TORQUE:  
JS-254 2.5 inch pounds  
all others 1.5 inch pounds  
All standard JS actuators in the SM Sec-  
tion of Catalog 10 can be used with the  
HM line. However, hardware, insulator,  
See optional mounting plate – previous and oil impregnated roller supplied with  
page.  
these actuators may not provide the re-  
quired service at temperatures above  
250°F (121°C).  
20 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Position Sensors  
HM Series  
Miniature Hermetically Sealed Switches  
HM MOUNTING DIMENSIONS (For reference only)  
Pin plunger s witches  
Fig. 1  
Fig. 2  
MOUNTING HOLES WILL ACCEPT PINS OR  
SCREWS OF 1,9/.08 DIA  
Fig. 4  
Fig. 3  
Auxiliary actuators  
Fig. 5  
Fig. 6  
Fig. 8  
Fig. 7  
HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada 21  
Position Sensors  
HT Series  
High Temperature Basic Switches  
GENERAL INFORMATION  
FEATURES  
HT switches will withstand temperatures  
up to +1000F. The switching element is  
mounted on a ceramic base within a  
stainless steel enclosure. HT switches are  
not classified as sealed switches.  
ɀ
Temperature tolerance up to +1000°F  
(538°C)  
Designed to meet military applications  
Side and panel mount  
UL recognized  
ɀ
ɀ
ɀ
ELECTRICAL RATINGS  
Circuitry  
Electrical Rating  
Single-Pole  
UL Ratings:  
Double-Throw  
3 amps, 1/10 HP, 125 vac.  
3 amps, 1/6 HP, 250 vac.  
Characteris tics : O.F. – Operating Force; R.F. – Release Force;  
HT ORDER GUIDE  
P.T. – Pretravel; O.T. – Overtravel; O.P. – Operating Position  
O.F.  
newtons  
ounces  
R.F. min.  
newtons  
ounces  
P.T. max.  
mm  
inches  
O.T. min.  
mm  
inches  
O.P.  
mm  
inches  
Des cription  
Straight plunger panel  
mount  
2,78-5,56  
10-20  
1,67  
6
1,65  
.065  
4,78  
.188  
23,7  
.935  
approx.  
Fig. 1  
Roller plunger panel  
mount  
8,34  
30 max.  
1,67  
6
1,65  
.065  
4,78  
.188  
35,9  
1.413  
approx.  
Fig. 2  
Fig. 3  
Pin plunger side mount  
2,78-5,56  
10-20  
1,67  
6
1,27  
.050  
0,25  
.010  
16,8  
.66  
approx.  
HT MOUNTING DIMENSIONS (For reference only)  
Fig. 1  
Mounting holes will accept pins or  
screws of .139(3,53 mm) dia.  
Fig. 2  
Fig. 3  
24 HoneywellSensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-416-293-8111 Canada  
Basic Switches  
MT Series  
Magnetic Blow-out  
FEATURES  
GENERAL INFORMATION  
MT (single-pole double-throw) magnetic  
Mechanical life of 100,000 operations blow-out switches are designed to switch  
— 95% survival high capacity (125 and 250 VDC) sys-  
Temperature tolerance to +180°F tems. An integral magnet around the con-  
ɀ
ɀ
Arc resistant case  
ɀ
ɀ
ɀ
(82°C)  
tact gap protects the contacts by deflect-  
ing the arc. Vents between the cover and  
housing allow the hot gas to escape.  
These switches are designed for the con-  
trol of DC motors, solenoids, etc.  
Mounting interchangeability with  
switches  
Z
UL recognized  
AVAILABLE TERMINALS  
Solde r (No lis ting de s ignation)  
A28  
6-32NC .218Screws  
will accept up to # 12 wire.  
ELECTRICAL RATING  
Ele ctrical Data and  
UL Code s  
Circuitry  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
K
Rating established with  
switch non-polarized  
10 amps, 125 vac or vdc;  
1/4 hp, 125 vac or vdc.  
UL Code L 168  
Non-polarized:  
10 amps res. or 1/4 hp, 125 vdc;  
3 amps max. res. 250 vdc.  
Polarized*:  
10 amps res. or 1/2 hp, 125 vdc;  
3 amps max. res., 250 vdc.  
*To polarize, connect negative side of line to common terminal. To  
achieve the same effect, mount switch with brass screws, using a  
non-magnetic barrier (at least 1⁄  
mounting surface.  
4
thick) between the switch and  
Characteris tics : O.F. – Operating Force;  
R.F. – Release Force; P.T. – Pretravel;  
O.T. – Overtravel; D.T. – Differential Travel;  
O.P. – Operating Position.  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
O.F.  
newtons  
ounce s  
R.F. min. P.T. max. O.T. min.  
D.T. max.  
mm  
inche s  
O.P.  
mm  
inche s  
newtons  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
Pin plunger  
SPDT  
10 Amps  
3,34-5,0  
12-18  
1,39  
1,02  
0,13  
0,1-0,18  
.004-.007  
15,9±0,38  
.625±.015  
K
5
.04  
.005  
Dim. Dwg. Fig. 1  
70 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
MT Series  
Magnetic Blow-out  
ORDER GUIDE  
Ele ctrical O.F. max. R.F. min. P.T. max. O.T. min.  
D.T. max.  
mm  
inche s  
O.P.*  
mm  
inche s  
Data and  
UL Code s  
newtons  
ounce s  
newtons  
ounce s  
mm  
inche s  
mm  
inche s  
De s cription  
Straight lever  
10 Amps  
0,56  
0,14  
12,7  
1,19  
2,16  
19,1  
K
2
0.5  
0.5  
.047  
.085  
.750  
Dim. Dwg. Fig. 2  
1.90 inch (48,3mm) lever  
with hardened steel roller  
10 Amps  
0,76  
2.75  
0,07  
0.25  
8,89  
0.35  
0,79  
.031  
1,65  
.065  
30,2  
1.188  
K
1.03 inch (26,2mm) lever  
with hardened steel roller  
10 Amps  
1,25  
4.5  
0,28  
1
5,08  
.200  
0,38  
.015  
0,89  
.035  
31,3  
1.234  
K
Dim. Dwg. Fig. 3  
1.95 inch (49,5mm)  
flexible leaf  
10 Amps  
3,34  
12  
0,28  
1
1,52  
.060  
max.  
19,1  
.750  
K
Dim. Dwg. Fig. 4  
1.82 inch (46,2mm)  
flexible leaf with hardened  
steel roller  
10 Amps  
3,34  
12  
0,28  
1
1,52  
.060  
max.  
30,2  
1.188  
K
Dim. Dwg. Fig. 5  
Except where stated * ±0,76 mm  
±.030 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 71  
Basic Switches  
MT Series  
Magnetic Blow-out  
MOUNTING DIMENSIONS (For reference only)  
PIN PLUNGER  
STRAIGHT LEVER  
Fig. 1  
Fig. 2  
ROLLER LEVER  
FLEXIBLE LEAF  
Fig. 3  
Fig. 4  
FLEXIBLE ROLLER LEAF  
Fig. 5  
Mounting holes accept pins or screws of  
.139 (3,53 mm) diameter.  
72 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
CUT-A-WAY V3 MINIATURE BASIC SWITCH  
FEATURES  
ɀ
ɀ
ɀ
ɀ
Low operating force to .53 ounce  
maximum  
Sensitive differential travel as low as  
.006 inch maximum  
Power load switching capability up to  
25 amperes–silver contacts  
Gold alloy crosspoint, silver cadmium,  
and other contact material for special  
applications  
ɀ
Long mechanical life of 10,000,000 cy-  
cles95% survival for V3-100, V3-1100,  
V3-2100, V3-3000 Series  
ɀ
ɀ
Temperature tolerance up to +180°F  
(82°C) on standard construction  
High temperature construction for use  
up to +600°F (316°C)  
3,1 mm mounting holes available  
UL recognized File # E12252, CSA cer-  
tified File # LR41370  
GENERAL INFORMATION  
There is a choice of SPDT, SPNC, and  
SPNO circuitry. Many lever styles, contact  
materials, and terminal variations can be  
furnished. Contact the 800 number for or-  
dering information.  
V3 miniature basic switches feature high  
electrical capacity and long life. Their size  
and shape meet design requirements in  
all types of applications.  
ɀ
ɀ
AVAILABLE TERMINALS  
SOLDER  
SHORT SOLDER  
SCREW  
D8  
QUICK CONNECT  
D9  
Dimensions shown are for reference only  
Mounting torque:  
2 inch pounds min.  
5 inch pounds max.  
.188 wide × .020 thick terminals  
.250 wide × .032 thick terminals  
This section covers only 60 of our most popular V3 Series catalog listings. If you dont find what youre looking for, it’s likely  
one of the approximately 850 other active V3 listings will meet your needs. Contact the 800 number.  
32 Honeywell ɀ MICRO SWITCH Sensing and Control  
For application help: call 1-800-537-6945.  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. –  
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating  
Position.  
ORDER GUIDE by as cending electrical capability  
PIN PLUNGERS  
Ele ctrical  
Data And  
UL Code  
Page 20  
R.F.  
min.  
P.T.  
max.  
mm  
O.T.  
min.  
mm  
O.F.  
D.T.  
mm  
inche s  
O.P.**  
mm  
inche s  
newtons newtons  
Re comme nde d For  
ounce s  
ounce s  
inche s  
inche s  
General use. Gold  
alloy crosspoint  
contacts.  
1 Amp  
X
2,22  
8 max.  
0,56  
2
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
Lowest force.  
3 Amps  
VV  
0,15  
.53  
1,2  
.047  
1,27  
.050  
0,051-0,25  
.002-.010  
14,7  
.578  
Lower force.  
5 Amps  
YY  
0,24  
.9  
1,2  
.047  
1,27  
.050  
0,051-0,25  
.002-.010  
14,7  
.578  
Most 5 amp  
applications.  
5 Amps  
ZZ  
2,22  
8
0,56  
2
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
Dim. Dwg. Fig. 1  
General use.  
10 Amps  
TT  
0,72 max.  
0,10  
.35  
1,2  
.047  
1,27  
.050  
0,051-0,25  
.002-.010  
14,7  
.578  
2.6  
Low force.  
10 Amps  
0,50 max.  
0,05  
.18  
1,2  
.047  
1,27  
.050  
0,051-0,25  
.002-.010  
14,7  
.578  
V
1.8  
Higher force. Most  
applications.  
11 Amps  
2,22  
8 max.  
0,56  
2
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
T
Highest force. Up to  
15.1 amps load  
handling with reduced  
life.  
15.1 Amps  
1,67-3,89  
6-14  
1,11  
4
1,21  
.047  
1,0  
.040  
0,15-0,4  
.006-.016  
14,7  
.578  
U
High force. Up to 15.1  
amps load handling.  
15,1 Amps  
1,47 max.  
0,15  
.53  
1,2  
.047  
1,27  
.050  
0,051-0,25  
.002-.010  
14,7  
.578  
U
5.3  
Up to 20 amps load  
handling  
20 Amps  
AA  
0,63 - 1,22  
2.3 - 4.4  
0,20  
0.7  
1,2  
.047  
1,27  
.050  
0,25  
.010 max.  
14,7  
.578  
Up to 25 amps load  
handling  
25 Amps  
BB  
1,22 - 2,20  
4.4 - 7.9  
0,31  
1.1  
1,2  
.047  
1,27  
.050  
0,25  
.010 max  
14,7  
.578  
MIL-S-8805 application  
requirements (SPDT)  
10 Amps  
UU  
1,67-3,89  
6-14  
1,11  
4
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
MIL-S-8805 application  
requirements (SPNC)  
10 Amps  
UU  
1,67-3,89  
6-14  
1,11  
4
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
MIL-S-8805 application  
requirements (SPNO)  
10 Amps  
UU  
1,67-3,89  
6-14  
1,11  
4
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
Dim. Dwg. Fig. 2  
Operating in  
temperature to  
+302°F (150°C)  
11 Amps  
2,22  
8 max.  
0,56  
2
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
T
Operating in  
temperature to  
+400°F (204°C)  
10 Amps  
2,78-6,95  
10-25  
1,67  
6
1,2  
.047  
1,02  
.040  
0,15-0,41  
.006-.016  
14,7  
.578  
W
*For actuators, contact MICRO SWITCH Sales Office.  
**Tolerances ±0.38  
±0.15  
ORDER GUIDE  
SIMULATED  
ROLLER  
Ele ctrical Le ngth of  
Data And Le ve r ‘A’’  
O.F.  
max.  
newtons newtons  
ounce s  
R.F.  
min.  
P.T.  
max.  
mm  
O.T.  
min.  
mm  
D.T.  
max.  
mm  
O.P.*  
mm  
inche s  
UL Code  
Page 20  
mm  
inche s  
Re comme nde d For  
ounce s  
inche s  
inche s  
inche s  
General use.  
10 Amps  
TT  
32,6  
1.285  
0,39  
1.4  
0,05  
.18  
2,54  
.100  
2,03  
.080  
0,76  
.030  
18,5  
.730  
Low force.  
10 Amps  
32,6  
1.285  
0,33  
1.2  
0,02  
.07  
2,54  
.100  
2,03  
.080  
0,76  
.030  
18,5  
.730  
V
High force. Most  
applications.  
11 Amps  
32,6  
1.285  
1,11  
4
0,14  
.5  
3,18  
.125  
1,57  
.062  
0,81  
.032  
18,5  
.730  
T
Highest force. Up to  
15.1 amps load  
handling with  
15.1 Amps  
32,6  
1.285  
2,22  
8
0,28  
1
3,18  
.125  
1,57  
.062  
0,81  
.032  
18,5  
.730  
U
Dim. Dwg. Fig. 3  
reduced life.  
High force. Up to  
15.1 amps load  
handling.  
15.1 Amps  
32,6  
1.285  
0,94  
3.4  
0,07  
.25  
2,54  
.100  
1,90  
.075  
0,76  
.030  
18,5  
.730  
U
*±1.5 mm  
±.060 in.  
For application help: call 1-800-537-6945.  
Honeywell ɀ MICRO SWITCH Sensing and Control 33  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. – Pre-  
travel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Posi-  
tion.  
ORDER GUIDE  
STRAIGHT LEVERS  
Ele ctrical Le ngth of  
Data And Le ve r ‘A’’ max.  
O.F.  
R.F.  
min.  
P.T.  
max.  
O.T.  
min.  
mm  
D.T.  
max.  
mm  
O.P.  
mm  
inche s  
UL Code  
Re comme nde d For Page 20  
mm  
inche s  
newtons newtons mm  
ounce s ounce s inche s inche s inche s  
General use.  
10 Amps  
TT  
21,3  
.860  
0,72  
2.6  
0,10  
.35  
1,5  
.060  
1,14  
.045  
0,33  
.013  
15,2±0,51  
.600±.020  
Low force. Added  
overtravel.  
10 Amps  
21,3  
.860  
0,50  
1.8  
0,50  
.18  
1,5  
.060  
1,14  
.045  
0,33  
.013  
15,2±0,51  
.600±.020  
V
Higher force. Most  
applications.  
11 Amps  
21,3  
.860  
2,50  
9
0,56  
2
1,5  
.060  
1,02  
.040  
0,41  
.016  
15,2±0,51  
.600±.020  
T
Highest force. Up to  
15.1 amps load  
handling with  
15.1 Amps  
21,3  
.860  
3,89  
14  
0,83  
3
1,5  
.060  
1,02  
.040  
0,41  
.016  
15,2±0,51  
.600±.020  
Dim. Dwg. Fig. 4  
U
reduced life.  
High force. Up to  
15.1 amps load  
handling.  
15.1 Amps  
21,3  
.860  
1,47  
5.3  
0,15  
.53  
1,5  
.060  
1,02  
.040  
0,28  
.011  
15,2±0,51  
.600±.020  
U
General use.  
Low force.  
10 Amps  
TT  
35,6  
1.40  
0,39  
1.4  
0,04  
.14  
2,79  
.110  
2,29  
.090  
0,76  
.030  
15,2±1,5  
.600±.060  
10 Amps  
35,6  
1.40  
0,31  
1.1  
0,02  
.07  
2,79  
.110  
2,29  
.090  
0,76  
.030  
15,2±1,5  
.600±.060  
V
Higher force. Most  
applications.  
11 Amps  
35,6  
1.40  
1,11  
4
0,14  
.5  
3,18  
.125  
2,29  
.090  
1,27  
.050  
15,2±1,5  
.600±.060  
T
Highest force. Up to  
15.1 amps load  
handling with  
15.1 Amps  
35,6  
1.40  
2,22  
8
0,28  
1
3,18  
.125  
2,29  
.090  
1,27  
.050  
15,2±1,5  
.600±.060  
Dim. Dwg. Fig. 4  
U
reduced life.  
High force. Up to  
15.1 amps load  
handling.  
15.1 Amps  
35,6  
1.40  
.86  
3.1  
0,06  
.21  
3,05  
.120  
2,29  
.090  
0,81  
.032  
15,2±1,5  
.600±.060  
U
Lower force.  
General use.  
Low force.  
5 Amps  
YY  
59,4  
2.34  
0,07  
.25  
5,08  
.200  
4,06  
.160  
1,4  
.055  
15,2±2  
.600±.080  
10 Amps  
TT  
59,4  
2.34  
0,22  
.81  
0,02  
.07  
5,08  
.200  
4,06  
.160  
1,4  
.055  
15,2±1,8  
.600±.070  
10 Amps  
59,4  
2.34  
0,16  
.56  
0,01  
.04  
5,08  
.200  
4,06  
.160  
1,4  
.055  
15,2±1,8  
.600±.070  
V
Higher force. Most  
applications.  
11 Amps  
59,4  
2.34  
0,58  
2.1  
0,12  
.42  
6,6  
.260  
3,81  
.150  
2,29  
.090  
14,7±2  
.580±.080  
T
Highest force. Up to  
15.1 amps load  
handling with  
15.1 Amps  
59,4  
2.34  
1,11  
4
0,14  
.50  
6,95  
2.60  
3,81  
.150  
2,29  
.090  
14,35±1,5  
.565±.060  
Dim. Dwg. Fig. 4  
U
reduced life.  
High force. Up to  
15.1 amps load  
handling.  
15.1 Amps  
59,4  
2.34  
0,39  
1.4  
0,03  
.11  
5,33  
.210  
4,06  
.160  
1,52  
.060  
15,2±1,9  
.600±.075  
U
Lowest force.  
3 Amps  
VV  
69,45  
2.75  
0,03  
.11  
5,97  
.235  
5,08  
.200  
1,60  
.063  
15,2±2,54  
.600±.100  
General use.  
10 Amps  
TT  
69,45  
2.75  
0,19  
.70  
0,01  
.04  
7,74  
.305  
3,68  
.145  
1,65  
.065  
15,31±2,54  
.603±.100  
Most applications.  
11 Amps  
69,45  
2.75  
0,54  
1.93  
0,10  
.36  
0,76  
.300  
4,57  
.180  
2,54  
.100  
14,48±2,03  
.570±.080  
T
Dim. Dwg. Fig. 4  
Highest force. Up to  
15.1 amps load  
handling with  
15.1 Amps  
69,45  
2.75  
0,83  
3
0,14  
.50  
8,38  
.330  
4,32  
.170  
2,54  
.100  
13,72±2,03  
.540±.080  
U
reduced life.  
34 Honeywell ɀ MICRO SWITCH Sensing and Control  
For application help: call 1-800-537-6945.  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
ORDER GUIDE  
ROLLER LEVERS  
Ele ctrical Le ngth of  
Data And Le ve r ‘A’’ O.F. max. R.F. min.  
P.T. max.  
mm  
inche s  
O.T. min. D.T. max.  
O.P.  
mm  
inche s  
Re comme nde d UL Code s  
mm  
inche s  
newtons  
ounce s  
newtons  
ounce s  
mm  
mm  
For  
Page 20  
inche s  
inche s  
General use.  
10 Amps  
TT  
20,6  
.81  
0,89  
3.2  
0,10  
.35  
1,2  
.047  
1,14  
.045  
0,33  
.013  
20,6±0,76  
.810±.030  
Low force.  
10 Amps  
20,6  
.81  
0,58  
2.1  
0,03  
.11  
1,42  
.056  
0,86  
.034  
0,33  
.013  
20,6±0,76  
.810±.030  
V
Higher force.  
Most applications.  
11 Amps  
20,6  
.81  
2,22  
8
0,56  
2
1,5  
.060  
1,02  
.040  
0,41  
.016  
20,6±0,76  
.810±.030  
T
Highest force.  
Up to 15.1 amps  
load handling with  
reduced life.  
15.1 Amps  
20,6  
.81  
3,89  
14  
0,83  
3
1,52  
.060  
1,02  
.040  
0,41  
.016  
20,6±0,76  
.810±.030  
U
Dim. Dwg. Fig. 7  
High force.  
Up to 15.1 amps  
load handling.  
15.1 Amps  
20,6  
.81  
1,89  
6.8  
0,15  
.53  
1,2  
.047  
1,02  
.040  
0,05 - 0,25  
.002 - .010 .810±.030  
20,6±0,76  
U
General use.  
10 Amps  
34  
0,44  
0,04  
3,18  
2,16  
0,76  
20,6±1,5  
TT  
1.34  
1.6  
.14  
.125  
.085  
.030  
.810±.060  
Low force.  
10 Amps  
34  
0,31  
0,02  
3,18  
2,16  
0,76  
20,6±1,5  
V
1.34  
1.1  
.07  
.125  
.085  
.030  
.810±.060  
Higher force.  
Most applications.  
11 Amps  
34  
1.34  
1,11  
4
0,14  
.5  
3,18  
.125  
2,16  
.085  
1,27  
.050  
20,6±1,5  
.810±.060  
T
Highest force.  
Up to 15.1 amps  
load handling with  
reduced life.  
15.1 Amps  
34  
1.34  
2,22  
8
0,28  
1
3,18  
.125  
2,16  
.085  
1,27  
.050  
20,6±1,5  
.810±.060  
U
Dim. Dwg. Fig. 7  
Higher force.  
Up to 15.1 amps  
15.1 Amps  
34  
1.34  
0,89  
3.2  
0,14  
.5  
3,18  
.125  
2,16  
.085  
0,76  
.030  
20,6±1,5  
.810±.060  
U
load handling.  
Characteris tics : O.F. — Operating Force; O.T. — Overtravel; D.T. — Differential Travel; R.F. — Release  
Force; P.T. — Pretravel; O.P. — Operating Position; F.P. — Free Position.  
* Characteristics taken with actuator assembled on Catalog Listing V3-1 switch as shown.  
AUXILIARY  
ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS  
ACTUATORS  
Actuator  
Le ngth ‘A’’ O.F. max  
R.F. min.  
newtons  
ounce s  
P.T. max.  
mm  
inche s  
O.T. min. D.T. max.  
O.P.  
mm  
inche s  
F.P. max.  
mm  
inche s  
mm  
newtons  
mm  
mm  
De s cription  
inche s  
ounce s  
inche s  
inche s  
Leaf type  
21,3  
3,34  
1,11  
1,19  
0,79  
0,41  
15±0,38  
16,4  
.84  
12  
4
.047  
.031  
.016  
.590±.015  
.645  
Dim. Dwg. Fig. 11  
Long leaf  
32,3  
1.27  
2,50  
9
1,11  
4
1,57  
.062  
1,27  
.050  
0,64  
.025  
14,5±0,76  
.570±.030  
17,4  
.685  
Dim. Dwg. Fig. 11  
Roller leaf  
20,6  
.81  
3,34  
12  
1,11  
4
1,52  
.060  
0,79  
.031  
0,41  
.016  
20,3±0,64  
.800±.025  
22,1  
.870  
Dim. Dwg. Fig. 11  
NOTE: Contact a MICRO SWITCH Sales Office for application assistance when actuators will be used at temperatures above 300°F (149°C).  
For application help: call 1-800-537-6945.  
Honeywell ɀ MICRO SWITCH Sensing and Control 35  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
Characteris tics : O.F. — Operating Force;  
R.F. — Release Force; P.T. — Pretravel;  
O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Positon; F.P. — Free Position  
* Characteristics taken with actuator assembled on Catalog Listing V3-  
100 switch as shown.  
AUXILIARY  
ACTUATORS  
ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS  
Switches are not included  
with actuators  
Actuator  
Le ngth ‘A’’ O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.  
mm  
F.P. max.  
mm  
mm  
newtons  
newtons  
mm  
mm  
mm  
De s cription  
inche s  
ounce s  
ounce s  
inche s  
inche s  
inche s  
inche s  
inche s  
Long lever  
44,5†  
1.75  
0,39  
1.4  
0,06  
.21  
8,33  
.328  
3,58  
.141  
4,75  
.187  
12,7±3,18  
.500±.125  
Dim. Dwg. Fig. 14  
Dim. Dwg. Fig. 14  
Dim. Dwg. Fig. 14  
Dim. Dwg. Fig. 11  
Roller lever  
19,1†  
.750  
0,83  
3
0,14  
.5  
4,78  
.188  
1,57  
.062  
1,98  
.078  
19,5±1,4  
.766±.055  
23,8  
.936  
Roller lever  
17,7†  
.695  
0,83  
3
0,14  
.5  
4,78  
.188  
1,57  
.062  
1,98  
.078  
19,5±1,1  
.766±.045  
23,8  
.936  
One-way roller  
lever  
20,6  
.81  
3,34  
12  
1,11  
4
2,03  
.080  
0,51  
.020  
0,38  
.015  
25,7±0,76  
1.010±.030  
27,7  
1.09  
Tandem leaf  
20,6  
.81  
5,00  
18  
1,67  
6
1,57  
.062  
0,89  
.035  
14,9±0,76  
.588±.030  
16,5  
.650  
Dim. Dwg. Fig. 17  
Tandem roller  
leaf  
20,6  
.81  
5,00  
18  
1,67  
6
1,57  
.062  
0,89  
.035  
20,5±0,76  
.806±.030  
21,8  
.860  
NOTE: Contact the 800 number for application assistance when actuators will be used at temperatures above 300°F (149°C).  
** Travel characteristics on tandem actuators vary with actual basic switch characteristics. These shown are typical for the  
assembly.  
‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing.  
Dim. Dwg. Fig. 17  
36 Honeywell ɀ MICRO SWITCH Sensing and Control  
For application help: call 1-800-537-6945.  
Obsolete  
Basic Switches  
V3 Series  
Miniature  
MOUNTING DIMENSIONS (for reference only)  
PIN PLUNGERS  
Fig. 1  
Fig. 2  
ROLLER LEVER  
SIMULATED ROLLER  
STRAIGHT LEVER  
Fig. 3  
Fig. 4  
Fig. 7  
AUXILIARY ACTUATORS  
Fig. 11  
Fig. 14  
NOTE: Operate point dimensions taken  
at top of lever/roller.  
Fig. 17  
For application help: call 1-800-537-6945.  
Honeywell ɀ MICRO SWITCH Sensing and Control 37  
Basic Switches  
V7 Series  
Miniature  
CUTAWAY V7 MINIATURE BASIC SWITCH  
FEATURES  
ɀ
Quick-connect and printed wiring  
board termination  
ɀ
ɀ
Proven V3 switching mechanism  
Physically interchangeable with exist-  
ing V3 switches  
ɀ
ɀ
All existing V3 lever options available  
UL recognized File # E12252; CSA cer-  
tified File # LR41370  
GENERAL INFORMATION  
ɀ
ɀ
ɀ
ɀ
International listings carry VDE  
approval  
The V7 Series is available in two versions, dard receptacles and connectors. The  
the Timesaver series and the International plastic enclosure meets VDE KC250 arc  
Power load switching capability up to series. The Timesaver series is UL recog- tracking requirement and is approvable  
21 amps nized and CSA certified. Timesaver series under the Refrigeration Industry Taste  
Temperature tolerance –40° to 185°F switches use readily available high-vol- and Odor test.  
(–40° to 85°C)  
High temperature construction  
available350°F  
ume components to provide especially  
responsive delivery performance. The In- OPERATING FORCES  
ternational V7 provides VDE approval in 175 grams (V rating only)  
addition to UL recognition and CSA certi- 150 grams (Not applicable to Electrical  
APPLICABLE EUROPEAN SYMBOLS  
µ = microgap construction. (The  
measurement between open  
fication.  
Rating V)  
75 grams (Not applicable to Electrical  
The V7 offers a choice of four quick-con- Rating C or V)  
nect and two printed wiring board termi- 50 grams (Not applicable to Electrical  
nal types. Three quick-connect types are Rating B, C, V)  
offset to meet international 3mm spacing 25 grams (Not applicable to Electrical  
requirements and one is designed for use Rating B, C, E, V)  
with molded connectors. Contact materi- 15 grams (Not applicable to Electrical Rat-  
al choice includes gold alloy, silver alloy ing A, B, C, E, S, V)  
or silver for handling various electrical  
contacts is less than 3mm).**  
= alternating current (used with  
value of voltage source:  
250V ).  
T = maximum rated use  
temperature; followed by the  
temperature value in °C  
(example T 85).  
loads. There are two mounting hole sizes  
available. Standard .114or 3mm to meet  
European design requirements.  
Mounting Torque:  
2 inch pounds min.  
5 inch pounds max.  
+++ = switch is rated for at least  
50,000 cycles at its rated  
current. (Sometimes referred  
to as ‘frequent operation.)  
10(3) = first number represents  
resistive rating. Second  
Terminal variations and switch dimen-  
sions of the European designed version  
conform to applicable DIN standards.  
These V7s mate with both standard do-  
mestic and international industry stan-  
number represents inductive  
(motor) rating.  
ELECTRICAL RATINGS  
A
B
C*  
D
E
F
S
V
1
1
3
5 amps, 125,  
250 or 277  
VAC; 110 hp,  
250 VAC  
11 amps and ⁄  
hp, 125, 250 or  
277 VAC; 1⁄  
amp, 125 VDC; amp, 125 VDC;  
3
15.1 amps and 1 amp, 125  
10 amps and ⁄  
hp 125 or 250  
3 amps, 125,  
250 or 277  
VAC; 110 hp,  
250 VAC  
.1 amp,  
125 VAC  
21 amps 125,  
250 or 277  
VAC, 1 HP 125,  
250, 277 VAC;  
2 HP, 250, 277  
VAC  
1
2
hp, 125, 250  
VAC  
2
or 277 VAC; 1⁄  
2
VAC; 1⁄  
2
amp,  
125 VDC; 1⁄  
4
1
1
4
4  
amp, 250  
amp, 250  
amp, 250 VDC;  
4 amps, 125  
VAC ‘‘L’’  
VDC; 4 amps,  
125 VAC ‘‘L’’  
VDC; 5 amps,  
120 VAC ‘‘L’’  
W
X
15.1 amps,  
6 amps; 1⁄  
HP  
8
125, 250 or 277 125, 250 or 277  
VAC VAC  
International Series Only  
10 (3) +++  
5 (2) +++  
250V  
T 85  
+++  
16 (4)  
250V  
T 85  
50E3 SPNO only  
250V  
T 85  
µ
µ
µ
* Available only when specifying 150 gram operating force.  
NOTE: ‘‘L’’ denotes lamp load.  
**The microgap construction (M) means contact gap is less than 3mm. Therefore, these products are suitable for secondary circuit use but not  
primary circuit use which requires a 3mm gap.  
38 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
V7 Series  
Miniature  
AVAILABLE TERMINALS  
Quick-connect  
D8*  
E8  
E9  
.187 Wide  
.020 Thick  
.187 Wide ⍥  
.020 Thick  
.250 Wide ⍥  
.032 Thick  
NOTE: D8 and E8 terminals are European ap-  
proved when used with electrical ratings B, D,  
or E. E9 terminals are European approved  
when used with electrical ratings B, C, D, or E.  
* International approving agencies will require that  
switches with these terminals have insulated re-  
ceptacles or connector.  
Printed Wiring Board  
PO1  
Printed wiring board terminals interface  
with snap-on receptacles and other com-  
ponents from AMPMODU interconnec-  
tion system.  
Dimensions shown are for reference  
only.  
PO2  
PO7  
This section covers only 48 of our most popular V7 Series catalog listings. If you dont find what youre looking for, it’s likely  
one of the approximately 300 other active V7 listings will meet your needs. Contact the 800 number.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 39  
Basic Switches  
V7 Series  
Miniature  
TIMERSAVER SERIES  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. –  
PIN PLUNGERS  
ORDER GUIDE - SPDT*  
Elect.  
Pretravel; O.T. – Overtravel; D.T. – Differential Travel.  
O.F. max.  
grams  
R.F. min.  
grams  
P.T. max.  
mm  
O.T. min.  
mm  
D.T.  
mm  
inches  
Rating  
P. 38  
ounces  
ounces  
inches  
inches  
1 Amp  
S
150  
5.3  
25  
.88  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
1 Amp  
S
50  
1.75  
5
.175  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
Dim. Dwg. Fig. 1  
5 Amps  
50  
1.75  
5
.175  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
A
11 Amps  
75  
2.63  
10  
.35  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
B
11 Amps  
75  
2.63  
10  
.35  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
B
15.1 Amps  
150  
5.3  
25  
.88  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
C
15.1 Amps  
W (350°F)  
300  
10.6  
25  
.88  
1,19  
.047  
1,27  
.050  
0,25  
.010 max.  
21 Amps  
175  
20  
1,19  
1,27  
0,05-0,25  
V
6.1  
.70  
.047  
.050  
.002-.010  
STRAIGHT LEVERS  
ORDER GUIDE - SPDT* .87LEVER TIMESAVER SERIES  
1 Amp  
S
54  
1.9  
3
.11  
1,52  
.060  
0,89  
.035  
0,33  
.013  
5 Amps  
160  
5.6  
7
.25  
1,52  
.060  
0.89  
.035  
0,38  
.015  
A
Dim. Dwg. Fig. 2  
11 Amps  
80  
2.8  
5
1.76  
1,52  
.060  
0,89  
.035  
0,38  
.015  
B
15.1 Amps  
160  
5.6  
17  
.60  
1,52  
.060  
0,89  
.35  
0,36  
.014  
C
21 Amps  
185  
13  
1,65  
0,89  
0,38  
V
6.5  
.5  
.065  
.035  
.015  
1.40LEVER TIMESAVER SERIES  
1 Amp  
S
30  
1.05  
1
3,04  
.120  
2,16  
.085  
0,76  
.030  
0.035  
5 Amps  
85  
3
8
.28  
3,04  
.120  
1,52  
.060  
0,76  
.030  
A
6 Amps  
X (350°F)  
185  
6.5  
15  
.53  
1,40  
.055  
0,76  
.030  
0,38  
.015  
Dim. Dwg. Fig. 5  
11 Amps  
82  
2.9  
8
.28  
3,04  
.120  
1,7  
.067  
0,68  
.027  
B
15.1 Amps  
82  
2.9  
8
.28  
3,04  
.120  
1,7  
.067  
0,76  
.030  
C
21 Amps  
95  
5
3,3  
1,78  
0,76  
V
3.3  
.18  
.130  
.070  
.030  
2.34LEVER TIMESAVER SERIES  
1 Amp  
S
16  
.56  
.5  
.018  
5,97  
.235  
3,0  
.118  
1,27  
.050  
11 Amps  
20  
.7  
1
.035  
5,97  
.235  
2.92  
.115  
1,27  
.050  
B
15.1 Amps  
85  
3
4
.14  
5,97  
.235  
1,65  
.065  
1,29  
.051  
C
15.1 Amps  
90  
4
6,35  
3,15  
1,37  
W (350°F)  
3.2  
.14  
.250  
.124  
.054  
* For SPST (N.O. & N.C.) circuitry, contact the 800 number.  
NOTE: Catalog listings in V7 Order Guides have standard .114mounting holes. For 3mm size holes, contact the 800  
number.  
40 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
V7 Series  
Miniature  
Characteris tics : O.F. – Operating Force; R.F. –  
Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T.  
– Differential Travel.  
SIMULATED  
ROLLER LEVERS  
ORDER GUIDE - SPDT*  
1.29LEVER TIMESAVER SERIES  
Elect.  
Rating  
P. 38  
O.F. max.  
grams  
ounces  
R.F. min.  
grams  
ounces  
P.T. max.  
mm  
inches  
O.T. min.  
mm  
inches  
D.T. max.  
mm  
inches  
Catalog  
Lis ting  
1.29LEVER TIMESAVER SERIES  
1 Amp  
S
90  
3.15  
9
.32  
2,79  
.110  
1,9  
.075  
0,76  
.030  
11 Amps  
90  
3.15  
9
.32  
2,79  
.110  
1,52  
.060  
0,76  
.030  
B
15.1 Amps  
91  
3.19  
9
.32  
2,79  
.110  
1,54  
.061  
0,61  
.024  
Dim. Dwg. Fig. 3  
Dim. Dwg. Fig. 4  
Dim. Dwg. Fig. 7  
C
.81ROLLER LEVER TIMERSAVER SERIES  
1 Amp  
S
90  
3.15  
7
.25  
1,19  
.047  
1,02  
.040  
0,38  
.015  
11 Amps  
88  
3.1  
7
.25  
1,3  
.052  
1,04  
.041  
0,3  
.012  
B
15.1 Amps  
176  
6.16  
19  
.67  
1,3  
.052  
0,81  
.032  
0,3  
.012  
C
21 Amps  
205  
7.2  
15  
.5  
1,42  
.056  
0,81  
.032  
0,33  
.013  
V
1.34ROLLER LEVER TIMESAVER SERIES  
1 Amp  
S
35  
1.23  
2
.07  
2,79  
.110  
2,03  
.080  
0,76  
.030  
5 Amps  
43  
1.51  
3
.105  
2,92  
.115  
1,52  
.060  
0,64  
.025  
A
15.1 Amps  
86  
3
9
.32  
2,84  
.112  
1,63  
.064  
0,64  
.025  
C
21 Amps  
100  
7
3,07  
1,65  
0,76  
V
3.5  
.25  
.121  
.065  
.030  
* For SPST (N.O. & N.C.) circuitry, contact the 800 number.  
NOTE: Catalog listing in V7 Order Guides have standard .114mounting holes. For 3mm size holes, contact the 800 number.  
ORDER GUIDE – ACCESSORIES  
Des cription  
Des cription  
Connector/Receptacle packet - Includes 25  
connectors and 75 receptacles with 18, blue 16  
gauge PVC insulated, stranded wire. (To be used  
with D8 terminals only).  
Insulator packet (500 pcs.) .018thick  
varnished fiberglass.  
Plunger boot seal. Elastomer dust and splash  
resistant plunger seal.  
Dimensions shown are for reference only.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 41  
Basic Switches  
V7 Series  
Miniature  
INTERNATIONAL SERIES  
PIN PLUNGER  
Characteris tics : O.F. – Operating Force; R.F. – Re-  
lease Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Dif-  
ferential Travel.  
ORDER GUIDE - SPDT*  
INTERNATIONAL SERIES  
Elect.  
Rating  
P. 38  
O.F. max.  
grams  
ounces  
R.F. min.  
grams  
ounces  
P.T. max.  
mm  
inches  
O.T. min.  
mm  
inches  
D.T.  
mm  
inches  
11 Amps  
150  
5.3  
25  
.88  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
B
11 Amps  
75  
2.63  
10  
.35  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
B
Dim. Dwg. Fig. 1  
11 Amps  
75  
2.63  
10  
.35  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
B
10 Amps  
50  
1.75  
5
.175  
1,19  
.047  
1,27  
.050  
0,05-0,25  
.002-.010  
E
10 Amps  
50  
5
1,19  
1,27  
0,05-0,25  
E
1.75  
.175  
.047  
.050  
.002-.010  
STRAIGHT LEVERS  
1.40 LEVER INTERNATIONAL SERIES  
11 Amps  
80  
2.8  
8
.28  
2,79  
.110  
2,28  
.090  
0,76  
.030  
B
11 Amps  
45  
1.58  
4
.14  
2,79  
.110  
2,28  
.090  
0,76  
.030  
B
10 Amps  
30  
1.05  
2
.070  
2,79  
.110  
2,28  
.090  
0,76  
.030  
Dim. Dwg. Fig. 5  
E
SIMULATED  
ROLLER LEVERS  
1.29LEVER INTERNATIONAL SERIES  
11 Amps  
50  
1.75  
5
.175  
2,54  
.100  
1,9  
.075  
0,76  
.030  
B
10 Amps  
33  
2
2,54  
1,9  
0,76  
E
1.16  
.070  
.100  
.075  
.030  
Dim. Dwg. Fig. 3  
ROLLER LEVERS  
ORDER GUIDE - SPDT* .81LEVER INTERNATIONAL SERIES  
11 Amps  
90  
3.15  
10  
.35  
1,19  
.047  
1,02  
.040  
0,38  
.015  
B
10 Amps  
62  
5
1,19  
1,02  
0,38  
E
2.17  
.175  
.047  
.040  
.015  
Dim. Dwg. Fig. 4  
1.34 LEVER INTERNATIONAL SERIES  
11 Amps  
45  
5
2,54  
2,16  
0,76  
B
1.58  
.175  
.100  
.085  
.030  
NOTE: Catalog listings in V7 Order Guides have standard .114mounting holes. For 3mm size holes, contact the 800  
number.  
Dim. Dwg. Fig. 7  
42 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
V7 Series  
Miniature  
MOUNTING DIMENSIONS (for reference only)  
PIN PLUNGER  
Fig. 1  
Fig. 2  
Straight Lever  
(Style-002)  
Fig. 3  
Simulated Roller  
(Style-263)  
Fig. 4  
Roller Lever  
(Style-201)  
Fig. 5  
Straight Lever  
(Style-022)  
Fig. 6  
Straight Lever  
(Style-048)  
Fig. 7  
Roller Lever  
(Style-207)  
NOTE: All levers are 0.17(4,31 mm) wide. Rollers are 0.19(4,82 mm) wide.  
NOTE: Operate point dimensions taken at top of lever/roller.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 43  
Basic Switches  
TB Series  
Miniature Double-break  
FEATURES  
GENERAL INFORMATION  
ɀ
Power load switching capability up to TB miniature switches are basic double-  
10 amperes  
Motor handling capacity of ⁄  
power, 125 VAC  
break units which offer a means of con-  
horse- trolling isolated circuits. Each circuit can  
be driven by independent voltage sourc-  
1
ɀ
2
ɀ
ɀ
ɀ
ɀ
ɀ
Two- and four-circuit double-break  
Several auxiliary actuators  
Choice of terminal styles  
UL recognized, CSA certified  
Momentary action  
es. These switches find many uses in  
modern control systems because of their  
circuitry.  
The terminals of two- and four-circuit dou-  
ble break switches must be wired to iden-  
tical voltage sources and the same polar-  
ity so that a voltage potential is not set up  
between adjacent terminals. A voltage  
potential between adjacent terminals  
could promote dielectric breakdown at  
high energy levels. The loads should be  
on the same sides of the line.  
Characteris tics : O.F. – Operating Force; R.F. – Release Force;  
P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P.  
– Operating Position.  
ORDER GUIDE  
Electrical  
Data And  
UL Code  
Page 20  
O.F.  
R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
inches  
O.P.**  
mm  
inches  
newtons newtons  
ounces  
mm  
mm  
Des cription  
ounces  
inches  
inches  
Two-circuit, double-  
break end screw  
terminals  
10 Amps  
1,95-3,61  
7-13  
1,11  
4
1,52  
.060  
0,25  
.010  
0,25-0,64  
.010-.025  
11,7  
.460  
Z
Dim. Dwg. Fig. 1  
Dim. Dwg. Fig. 2  
Dim. Dwg. Fig. 3  
Two-circuit, double-  
break end solder  
terminals  
10 Amps  
1,95-3,61  
7-13  
1,11  
4
1,52  
.060  
0,25  
.010  
0,25-0,64  
.010-.025  
11,7  
.460  
Z
Two-circuit, double-  
break front solder  
terminals  
10 Amps  
1,95-3,61  
7-13  
1,11  
4
1,52  
.060  
0,25  
.010  
0,25-0,64  
.010-0.25  
11,7  
.460  
Z
Four-circuit, double-  
break front solder  
terminals  
10 Amps  
5,56-10,0  
20-36  
2,22  
8
1,78  
.070  
0,25  
.010  
0,64-1,14  
.025-.045  
4,70  
.185  
Z
Dim. Dwg. Fig. 4  
* ±0,38 mm  
±.015 in  
44 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
TB Series  
Miniature Double-break  
AUXILIARY ACTUATORS  
For use with 1TB1-1 and 1TB1-2 switches  
ORDER GUIDE  
J T-1  
Des cription  
Leaf actuator  
Roller leaf actuator  
J T-5  
Switches are not included with the actuators.  
MOUNTING DIMENSIONS (For reference only)  
Fig. 1  
Fig. 2  
Fig. 3  
Fig. 4  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 45  
Basic Switches  
Standard  
BZ/BA Series  
FEATURES  
ɀ
Operating force as low as 4 oz. (113  
grams) maximum  
Sensitive differential travel as low as  
.0002 to .0003 inches (0,005 to 0,008  
mm)  
STANDARD BASIC SWITCH CUT-A-WAY  
The cut-a-way shown is representative of the standard basic switches described in this  
catalog.  
ɀ
ɀ
ɀ
Power load switching capability to 25  
amperes  
Motor handling capacity to 2 horse-  
power at 250 VAC  
ɀ
ɀ
Long mechanical life  
High temperature constructions for up  
to +400°F (204°C)  
ɀ
ɀ
Momentary or maintained contact  
action  
Alloy contacts available for special ap-  
plication needs  
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
Variety of integral actuators  
Variety of auxiliary actuators  
Variety of terminal designs  
Optional sealed plunger and cover  
Stainless steel snap spring available  
Military standard construction availa-  
ble with over 50 listings on the MIL-  
S-8805 Qualified products list  
UL recognized, CSA certified  
GENERAL INFORMATION  
The type BZ switch design meets most  
MICRO SWITCH standard basic switches applications needs. Modifications of the  
are precision snap-action mechanisms standard silver contact design and mate-  
enclosed in accurately molded plastic rial, spring configuration, and plunger lo-  
cases. These switches are carefully man- cations give the type BM, BA and BE  
ufactured and thoroughly inspected. switches greater electrical load handling  
They are industry known for their com- capacity. Other changes in materials and  
pactness, light weight, accurate repeata- switch design provide operating charac-  
ɀ
Characteristics as stated are taken at nor-  
mal room temperature and humidity.  
These may vary as temperature and hu-  
midity conditions differ.  
bility and long life.  
teristics, temperature tolerances, and  
sealing to cover a wide range of special  
requirements.  
MOUNTING DIMENSIONS  
Mounting dimensions are included at the  
end of each product section. They are  
shown in English and metric equivalents.  
GENERAL SWITCH IDENTIFICATION  
First letter in catalog listing designates:  
These dimensions are for reference only. B = Single-pole double-throw  
Forexacting layout work, request an engi- W = Single-pole single-throw (normally closed)  
neering layout work, request an engineer- Y = Single-pole single-throw (normally open)  
ing drawing from the 800 number.  
Second letter in catalog listing designates:  
Z = Standard 15-amp version  
M = 22-amp version  
A = Standard 20-amp version  
E = 25-amp version  
Mounting holes for Types BZ, BM, BA, BE,  
DT, MT, and 6AS switches accept pins or  
screws of .139 inch (3,53 mm) diameter.  
RECOMMENDED TORQUE (max.)  
Mounting screws . . . . . . . . . . . . 3 in./lbs.*  
Terminal screws . . . . . . . . . . . . . . 4 in./lbs.  
Panel mount bushing . . . . . . . 4-6 in./lbs.  
*Note: Tightening mounting screws  
above 3 in./lbs. changes operat-  
ing characteristics and increases  
the possibility of cracking the  
case.  
UL/CSA  
Our basic switches are Component Recognized by UnderwritersLaboratories, Inc. and certified by Canadian Standards Associ-  
ation. The BA, BZ, and BM line is covered as Special Use Switches to UL Standard 1054; the BE line is covered as an Industrial Motor  
Controller to UL Standard 508.  
Agency File References  
are:  
BA  
BM  
BZ  
BE-1,2,5  
BE-R  
UL File E12252, issued 12-09-88  
UL File E12252, issued 12-08-88  
UL File E12252, issued 6-29-89  
UL File E22779, Vol. 4, Sec. 1  
UL File E22779, Vol. 4, Sec. 2  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 47  
Basic Switches  
BZ/BA Series  
Standard  
AVAILABLE TERMINALS  
Most of the BZ/BA catalog listings have  
A2 type terminals. Several other terminal  
styles are shown and others are available.  
Specific information should be requested  
from the 800 number or local Authorized  
Distributor.  
ACTUATORS  
BA, BE, BM and BZ standard basic  
switches use the actuators described.  
48 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
Characteris tics : O.F. — Operating Force; R.F. — Release Force; P.T.  
— Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. —  
Operating Position.  
ORDER GUIDE by as cending electrical capability  
PIN PLUNGER  
BZ/BA TYPE  
Electrical  
Data And  
UL Codes newtons newtons  
Recommended For Page 46 ounces ounces  
O.F.  
R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
inches  
O.P.**  
mm  
inches  
mm  
mm  
inches  
inches  
Applications requiring  
gold alloy contacts  
1 Amp  
P
2,5-3,61  
9-13  
1,11  
0,38  
0,13  
0,01-0,05  
.0004-.0020  
15,88  
.625  
4
.015  
.005  
Gold alloy contacts  
Dustproof and splash  
resistant seal  
1 Amp  
P
2,22-4,17  
8-15  
1,11  
0,13  
0,01-0,06  
.0004-.0025  
15,88  
.625  
4
.005  
Operating in temp. to  
+400°F (204°C) for  
100 hours  
5 Amps  
B
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
Lower force  
10 Amps  
1,11  
4
0,7  
2.5  
0,30  
.012  
0,13  
.005  
0,005-0,013  
.0002-.0005  
15,88  
.625  
Dim. Dwg. Fig. 1  
C
Most applications  
SPDT  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
SPST (normally  
closed)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
SPST (normally open)  
Less differential travel  
Best repeatability  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
SEALED TYPE  
15 Amps  
1,95-2,5  
7-9  
1,11  
4
0,30  
.012  
0,13  
.005  
0,005-0,008  
.0002-.0003  
15,88  
.625  
D
15 Amps  
1,95-3,34  
7-12  
1,11  
4
0,30  
.012  
0,13-0,2  
.005-.008 .0002-.0008  
0,005-0,02  
16,26  
.640  
D
Operating in temp. to  
+250°F (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
Dim. Dwg. Fig. 2  
MIL-S-8805 application  
requirements  
15 Amps  
2,5-3,61  
9-13  
1,67  
6
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
Best stability under  
varying humidity  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
0,13  
.005  
0,01-0,05  
.0004-.0020  
15,88  
.625  
A
Dustproof and splash  
resistant seal  
15 Amp  
A
2,5-4,17  
9-15  
1,11  
4
0,13  
.005  
0,01-0,06  
.0004-.0025  
15,88  
.625  
Best service for sealed  
construction. Stainless  
steel internal snap  
spring.  
15 Amps  
2,5-4,17  
9-15  
1,11  
4
0,13  
.005  
0,01-0,06  
.0004-.0025  
15,88  
.625  
BA/BE TYPE  
A
Up to 20 ampere load  
handling  
20 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
0,25  
.010  
0,05-0,19  
.0020-.0075  
16,26  
.640  
G
Operating in  
temperature to +250°F  
(121°C)  
20 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
0,25  
.010  
0,05-0,19  
.0020-.0075  
16,26  
.640  
G
Dim. Dwg. Fig. 3  
Up to 22 ampere load  
handling  
22 Amps  
1,95-2,78  
7-10  
1,11  
4
0,38  
.015  
0,13  
.005  
0,013-0,025  
.0005-.0010  
15,88  
.625  
F
Up to 25 ampere load  
handling  
25 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
0,25  
.010  
0,05-0,19  
.0020-.0075  
16,26  
.640  
H
Manual reset  
15 Amps  
1,95-2,5  
7-9  
0,56-2,78*  
2-10  
0,30  
.012  
0,13  
.005  
0,38*  
.015  
15,88  
.625  
(maintained contact)  
applications, solder  
terminals  
E
Manual reset SPST-  
NC, A4 terminals  
20 Amps  
5,56  
20  
6,95*  
25  
0,25  
.010  
0,20  
.008  
16,26  
.64  
27,9*  
1.10  
W
Dim. Dwg. Fig. 4  
*Reset characteristics.  
Except where stated ** ±0,38mm  
±.015 in.  
All catalog listings shown are not  
necessarily stock items. Stocking  
depends on sales experience.  
Auxiliary actuators see p. 62-63.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 49  
Basic Switches  
BZ/BA Series  
Standard  
Characteris tics : O.F. — Operating Force;  
R.F. — Release Force; P.T. — Pretravel;  
O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position.  
OVERTRAVEL  
PLUNGER  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F.  
newtons  
ounce s  
R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
inche s  
O.P.*  
mm  
inche s  
newtons  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
Applications requiring gold  
alloy contacts  
1 Amp  
P
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
21,21  
.835  
Added overtravel. For  
manual operation and slow  
20° (max) cam rise  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
21,21  
.835  
Dim. Dwg. Fig. 11  
A
Operating in temperature  
to +250°F (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
21,21  
.835  
A
Up to 22 ampere load  
handling  
22 Amps  
1,95-2,78  
7-10  
1,11  
4
0,38  
.015  
1,52  
.060  
0,013-0,025  
.0005-  
21,21  
.835  
F
.0010  
Applications requiring gold  
alloy contacts plus  
dustproof and splash  
resistant seal  
1 Amp  
P
3,61-5,28  
13-19  
1,11  
4
1,52  
.060  
0,01-0,063  
.0004-  
.0025  
28,20  
1.110  
Dustproof and splash  
resistant seal  
15 Amps  
3,61-5,28  
13-19  
1,11  
4
1,52  
.060  
0,01-0,063  
.0004-  
28,20  
1.110  
A
.0025  
Dim. Dwg. Fig. 12  
Up to 20 ampere load  
handling  
20 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
2,39  
.094  
0,05-0,19  
.0020-  
.0075  
26,20  
1.03  
G
Up to 25 ampere load  
handling  
25 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
2,39  
.094  
0,05-0,19  
.0020-  
.0075  
26,20  
1.03  
H
Dim. Dwg. Fig. 13  
Applications requiring gold  
alloy contacts  
1 Amp  
P
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
28,20  
1.110  
Added overtravel. For  
in-line operation and with JR  
auxiliary actuators  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,063  
.0004-  
.0025  
28,20  
1.110  
A
Operating in temperature  
to +250°F (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
28,20  
1.110  
A
MIL-S-8805 application  
requirements  
15 Amps  
2,5-3,61  
9-13  
1,67  
6
0,38  
.015  
1,52  
.060  
0,01-0,05  
.0004-  
.0020  
28,20  
1.110  
A
Dim. Dwg. Fig. 14  
Manual reset  
15 Amps  
1,95-2,64  
0,30  
0,64  
2,79  
solder terminals  
E
7-9  
.012  
.025  
1.11  
Up to 22 ampere load  
handling  
22 Amps  
1,95-2,78  
7-10  
1,11  
4
0,38  
.015  
1,52  
.060  
0,013-0,025  
.0005-  
28,20  
1.110  
F
.0010  
Applications requiring gold  
alloy contacts plus  
dustproof and splash  
resistant seal  
1 Amp  
P
2,5-4,17  
9-15  
1,11  
4
1,52  
.060  
0,01-0,063  
.0004-  
.0025  
28,20  
1.110  
Dustproof and splash  
resistant seal  
15 Amps  
2,5-4,17  
9-15  
1,11  
4
1,52  
.060  
0,01-0,063  
.0004-  
28,20  
1.110  
A
.0025  
*±0,51 mm  
±.020 in.  
Dim. Dwg. Fig. 15  
50 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
ORDER GUIDE  
OVERTRAVEL  
PLUNGER  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F.  
newtons  
ounce s  
R.F. min.  
newtons  
ounce s  
P.T. max.  
mm  
inche s  
O.T. min.  
mm  
inche s  
D.T.  
mm  
inche s  
O.P.**  
mm  
inche s  
Re comme nde d For  
Added overtravel. For  
manual in-line operation and  
for slow 30° (max) rise cams  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
38,10±0,51  
1.500±.020  
A
Operating in temperature  
to ±250°F (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
38,10±0,51  
1.500±.020  
A
Dim. Dwg. Fig. 16  
Applications requiring gold  
alloy contacts  
1 Amp  
P
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
21,82  
.859  
BZ-2RQ-A2 type applications  
with panel mount  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
21,82  
.859  
BZ/BM TYPE  
A
MIL-S-8805 application  
requirements  
15 Amps  
2,5-3,61  
9-13  
1,67  
6
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
21,82  
.859  
A
Operating in temperature  
to ±250°F (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
5,56  
.219  
0,01-0,05  
.0004-  
.0020  
21,82  
.859  
A
Furnished with  
unassembled seal  
boot.  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
0.15  
3,18  
.125  
0,01-0,05  
.0004-  
.0020  
48,4±0,50  
1.906±.020  
Dim. Dwg. Fig. 17  
X
Manual reset.  
Solder terminals  
15 Amps  
1,67-2,64  
6-9.5  
0,30  
0.12  
5,56  
.219  
23,42±1,14  
.922±.045  
7,14*  
E
BA TYPE  
.281*  
Up to 20 ampere load  
handling  
20 Amps  
3,89-6,12  
14-22  
2,78  
10  
1,27  
.050  
5,56  
.219  
0,05-0,19  
.0020-  
.0075  
21,82  
.859  
G
Up to 22 ampere load  
handling  
22 Amps  
1,95-2,78  
7-10  
1,11  
4
0,38  
.015  
5,56  
.219  
0,013-  
0,025  
21,82  
.859  
F
.0005-  
.0010  
Dim. Dwg. Fig. 18  
Applications requiring gold  
1 Amp  
P
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
3,56  
.140  
0,01-0,05  
.0004-  
.0020  
33,32±1,14  
1.312±.045  
alloy contacts  
Added overtravel. Roller  
plunger for rapid cam (30°  
max) rise and slide  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
3,56  
.140  
0,01-0,05  
.0004-  
.0020  
33,32±1,14  
1.312±.045  
A
operation. Panel mount  
Operating in temperature  
to ±250°F) (121°C)  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
3,56  
.140  
0,01-0,05  
.0004-  
.0020  
33,32±1,14  
1.312±.045  
A
Double-break  
circuitry  
15 Amps  
3,89-6,68  
14-24  
1,11  
4
0,51  
.020  
3,58  
.141  
0,03-0,10  
.001-.004  
33,35±1,19  
1.313±.047  
T
Up to 22 ampere load  
handling  
22 Amps  
1,95-2,78  
7-10  
1,11  
4
0,38  
.015  
3,56  
.140  
0,013-  
0,025  
33,32±1,14  
1.312±.045  
Dim. Dwg. Fig. 19  
F
.0005-  
.0010  
Applications requiring  
roller plunger 90° to major  
axis of switch  
15 Amps  
2,5-3,61  
9-13  
1,11  
4
0,38  
.015  
3,56  
.140  
0,01-0,05  
.0004-  
.0020  
33,32±1,14  
1.312±.045  
A
* Reset characteristics.  
Except where stated ** ±0,76 mm  
±.030 in.  
Dim. Dwg. Fig. 20  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 51  
Basic Switches  
BZ/BA Series  
Standard  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position.  
STRAIGHT LEVER  
ORDER GUIDE  
Ele ctrical  
Data and O.F. max. R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
O.P.**  
mm  
Re comme nde d  
For  
UL Code s newtons newtons  
mm  
mm  
Page 46  
ounce s ounce s  
inche s  
inche s  
inche s  
inche s  
Applications  
requiring gold alloy  
contacts  
1 Amp  
P
0,7  
0,14  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
2.5  
0.5  
BZ/BM TYPE  
Best stability under  
varying humidity.  
Gold alloy contacts  
with seal  
1 Amp  
P
0,7  
0,14  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
2.5  
0.5  
Operating in temp.  
to +400°F (204°C)  
for 100 hours  
5 Amps  
B
0,7  
2.5  
0,14  
0.5  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
Lowest operating  
force (without  
external return  
spring)  
10 Amps  
0,07  
.25  
6,76  
.266  
5,56  
.219  
0,08-0,38  
.003-.015  
19,1  
.750  
I
Dim. Dwg. Fig. 21  
1.25 inch lever  
requirements  
15 Amps  
1,67  
6
0,42  
1.5  
0,42  
.141  
0,10-0,63  
.004-.025  
19,1  
.750  
A
2.5 inch lever  
requirements  
15 Amps  
0,7  
2.5  
0,14  
0.5  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
A
Lower force (without  
external return  
spring)  
15 Amps  
0,28  
1
0,03  
0.125  
8,33  
.328  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
A
BA TYPE  
Dustproof and  
15 Amps  
0,7  
0,14  
5,56  
0,181,27  
19,1  
splash resistant seal  
A
2.5  
0.5  
.219  
.007-.050  
.750  
MIL-S-8805  
application  
requirements  
15 Amps 0,28-0,90  
0,21  
0.75  
7,52  
.296  
4,37  
.172  
2,36  
.093  
19,1  
.750  
A
1-3.25  
Operating in  
temperature to  
+250°F (121°C)  
15 Amps  
0,7  
2.5  
0,14  
0.5  
5,56  
.219  
0,18-1,27  
.007-.050  
19,1  
.750  
A
Manual reset solder  
terminals  
15 Amps  
0,63  
2.25  
5,56  
.219  
0,38*  
.015  
19,05  
.750  
7,14*  
.281  
Dim. Dwg. Fg. 23  
E
6 inch lever  
requirements  
15 Amps  
0,28  
1
12,7  
.500  
0,46-3,68 19,1±1,52  
.018-.145 .750±.060  
A
Up to 20 ampere  
load handling  
20 Amps  
0,7  
2.5  
0,14  
0.5  
15,88  
.625  
1,98  
.078  
2,77  
19,1  
G
.109  
.750  
Up to 22 ampere  
load handling  
22 Amps  
0,28  
1
0,03  
0.125  
7,54  
.297  
5,56  
.219  
0,13-0,84  
.005-.033  
19,1  
.750  
F
Up to 25 ampere  
load handling  
25 Amps  
0,7  
2.5  
0,14  
0.5  
15,88  
.625  
1,98  
.078  
2,77  
.109 max.  
19,1  
.750  
H
ADJ USTABLE  
* Reset characteristics.  
Adjustable  
15 Amps  
0.7  
0.14  
3,54†  
0,18-1,27 17,02-22,35  
operating point (17  
mm to 22 mm) .670  
to .880⍯  
A
2.5  
0.5  
.125  
.007-.050 .670-.880  
Reverse acting  
15 Amps  
1,67  
6
0,28  
1
5,56  
.219  
5,56  
.219  
0,10-0,89  
.004-.035  
19,1  
.750  
Dim. Dwg. Fg. 22  
actuator (switch  
plunger depressed  
in free position)  
A
Except where stated ** ±0.76 mm  
±.030 in.  
17 mm  
.670 in.  
† From  
O.P.  
Dim. Dwg. Fig. 24  
52 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
SIMULATED ROLLER  
ORDER GUIDE  
Ele ctrical  
Data And  
O.F.  
max.  
R.F.  
min.  
P.T.  
max.  
mm  
O.T.  
min.  
mm  
D.T.  
mm  
inche s  
O.P.**  
mm  
inche s  
UL Code newtons newtons  
Re comme nde d For Page 46  
ounce s ounce s inche s  
inche s  
1.05 inch (26,7 mm)  
(simulated roller)  
lever applications  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
A
1.90 inch (48,3 mm)  
(simulated roller)  
lever applications  
15 Amps  
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,10-1,0  
.004-.040 1.188±.030  
30,17±0,76  
A
Dim. Dwg. Fig. 27  
ROLLER LEVER  
Applications  
requiring gold alloy  
contacts  
1 Amp  
P
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
Applications  
requiring gold alloy  
1 Amp  
P
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
BZ/BM TYPE  
contacts plus  
dustproof and splash  
resistant seal  
1.05 inch (26,7 mm)  
(steel roller) lever  
applications  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
A
Roller turned 90°  
15 Amps  
0,7-1,81  
2.5-6.5  
0,35  
1.25  
3,58  
0,08-0,51  
30,75  
1.25  
A
.141 max. .003-.020  
Dim. Dwg. Fig. 25  
Operating in  
temperature to  
+250°F (121°C)  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
A
Dustproof and  
splash resistant seal  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
A
Best service for  
sealed construction.  
Stainless steel  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
30,17  
1.188  
A
internal snap spring.  
Up to 20 ampere  
load handling  
20 Amps  
1,67  
6
0,42  
1.5  
6,35  
.250  
0,76  
.030  
1,14  
.045 max.  
29,77  
1.172  
G
Dim. Dwg. Fig. 28  
Up to 22 ampere  
load handling  
22 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,025-0,33  
.001-.013  
30,17  
1.188  
F
Up to 25 ampere  
load handling  
25 Amps  
1,67  
6
0,42  
1.5  
6,35  
.250  
0,76  
.030  
1,14  
.045 max.  
29,77  
1.172  
H
BA/BE TYPE  
Adjustable operating  
point. Roller lever  
1.05 inch (26,7 mm)  
15 Amps  
1,67  
6
0,42  
1.5  
1,02  
.040  
0,08-0,51 29,77-30,56  
.003-.020 1.172-1.203  
A
Adjustable operating  
point. Roller lever  
15 Amps  
0,97  
3.5  
0,21  
0.75  
2,16  
.085  
0,10-1,0  
29,2-31,5  
A
.004-.040 1.150-1.24  
1.90 inch (48,3 mm)  
Dim. Dwg. Fig. 26  
Except where stated * ±0,38 mm  
±.015 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 53  
Basic Switches  
BZ/BA Series  
Standard  
Characteris tics :  
O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel;  
O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position.  
ROLLER LEVER  
ORDER GUIDE  
Ele ctrical  
Data And  
UL Code newtons newtons  
O.F.  
max.  
R.F.  
min.  
P.T.  
max.  
mm  
O.T.  
min.  
mm  
D.T.  
mm  
O.P.*  
mm  
Re comme nde d  
For  
BZ/BM TYPE  
Page 46  
ounce s ounce s inche s  
inche s  
inche s  
inche s  
Applications requiring  
gold alloy contacts,  
1 Amp  
P
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,10-1,0  
.004-.040 1.188±.030  
30,17±0,76  
plus dustproof, and  
splash resistant seal  
1.90 inch (48,3 mm)  
(steel roller) lever  
applications  
15 Amps  
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,10-1,0  
.004-.040 1.188±.030  
30,17±0,76  
A
Dim. Dwg. Fig. 29  
Dustproof and splash  
resistant seal  
15 Amps  
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,10-1,0  
.004-.040 1.188±.030  
30,17±0,76  
A
BA/BE TYPE  
Operating in  
temperature to  
+250°F (121°C)  
15 Amps  
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,10-1,0 30,17±0,76  
.004-.040 1.188±.030  
A
Up to 20 ampere load  
handling  
20 Amps  
0,97  
3.5  
0,14  
0.5  
11,89  
.468  
1,52  
.060  
2,16  
.085  
30,17±0,76  
1.188±.030  
G
Up to 22 ampere load  
handling  
22 Amps  
0,97  
3.5  
0,21  
0.75  
3,96  
.156  
0,08-0,56  
.003-.022 1.188±.030  
30,17±0,76  
F
Up to 25 ampere load  
handling  
25 Amps  
0,97  
3.5  
0,14  
0.5  
11,89  
.468  
1,52  
.060  
2,16  
30,17±0,76  
Dim. Dwg. Fig. 30  
H
.085 max. 1.188±.030  
NOTE: For adjustable operate point and simulated roller lever switches, refer to previous page.  
Best repeatability and  
O.P. stability  
10 Amps  
3,34  
12  
1,11  
4
0,38  
.015  
2,54  
.100  
0,013-0,025  
.0005-.0010  
31,37  
1.235  
I
Dim. Dwg. Fig. 31  
One-way roller (9,4  
mm 3,8 mm) .37⍯  
dia. .15wide roller  
15 Amps  
1,67  
6
0,42  
1.5  
2,39  
.094  
0,08-0,51  
.003-.020  
41,34  
1.625  
A
One-way roller (4,83  
mm 4,83 mm) .19⍯  
dia. .19wide roller  
15 Amps  
2,22  
8
0,42  
1.5  
1,52  
.060  
0,38  
.015  
28,96  
1.14  
A
Dim. Dwg. Fig. 32  
Except where stated * ±0,38 mm  
±.015 in.  
54 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
FLEXIBLE LEAF  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F. max.  
newtons  
ounce s  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.**  
mm  
inche s  
newtons  
mm  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
inche s  
BZ TYPE  
Force and stability of the  
flexible leaf actuator  
15 Amps  
1,39  
5
0,14  
1,52  
1,27  
17,48  
.688  
A
0.5  
.060  
.050  
Dustproof and splash  
resistant seal  
15 Amps  
1,95  
7
0,14  
0.5  
1,52  
.060  
1,27  
.050  
17,48  
.688  
A
MIL-S-8805 application  
requirements  
15 Amps  
1,39  
5
0,14  
0.5  
1,52  
.060  
1,27  
.050  
17,48  
.688  
Dim. Dwg. Fig. 33  
A
Operating in temperature  
to +250°F (121°C)  
15 Amps  
1,39  
5
0,14  
0.5  
1,52  
.060  
1,27  
.050  
17,48  
.688  
BA/BE TYPE  
A
Manual reset.  
Solder terminals  
15 Amps  
0,83  
3
1,57  
.062  
0,38*  
.015  
17,48  
.688  
7,14*  
.281  
E
Up to 20 ampere load  
handling  
20 Amps  
2,5  
9
0,28  
1
1,57  
.062  
1,57  
.062  
17,48  
.688  
Dim. Dwg. Fig. 34  
G
Up to 25 ampere load  
handling  
25 Amps  
2,5  
9
0,28  
1
1,57  
.062  
1,57  
.062  
17,48  
.688  
H
FLEXIBLE  
ORDER GUIDE  
ROLLER LEAF  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F. max.  
newtons  
ounce s  
R.F. min. P.T. max. O.T. min. D.T. max.  
O.P.*  
mm  
inche s  
newtons  
mm  
mm  
mm  
BZ TYPE  
Re comme nde d For  
ounce s  
inche s  
inche s  
inche s  
Operating in temp. to  
+250°F (121°C)  
for 100 hours  
5 Amps  
B
1,39  
5
0,14  
1,52  
1,27  
28,6  
1.125  
0.5  
.060  
.050  
Force and stability of the  
flexible leaf with roller  
15 Amps  
1,39  
5
0,14  
0.5  
1,52  
.060  
1,27  
.050  
28,6  
1.125  
A
Dim. Dwg. Fig. 35  
Dustproof and splash  
resistant seal  
15 Amps  
1,95  
7
0,14  
0.5  
1,52  
.060  
1,27  
.050  
28,6  
1.125  
A
BA/BE TYPE  
(
MIL-S-8805 application  
requirements  
15 Amps  
1,04-1,39  
3.75-5  
0,14  
0.5  
1,52  
.060  
1,27  
.050  
28,6  
1.125  
A
Up to 20 ampere load  
handling  
20 Amps  
2,5  
9
0,28  
1
1,52  
.060  
1,65  
.065  
28,6  
1.125  
G
Up to 25 ampere load  
handling  
25 Amps  
2,5  
9
0,28  
1
1,52  
.060  
1,65  
.065  
28,6  
1.125  
H
* Reset characteristics  
Dim. Dwg. Fig. 36  
** ±0.76 mm  
±.030 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 55  
Basic Switches  
BZ/BA Series  
Standard  
GENERAL INFORMATION  
SPECIAL CIRCUITRY SWITCHES  
‘‘Special sequenceswitches provide un- provides a single pulse or momentary  
usual circuit control. A make-before- closure of the contacts with each cycle of  
break switch provides circuit continuity operation.  
while switching from N.C. to N.O. In an-  
other make-before-make switch, upon Double break versions can interrupt grea-  
actuation, one circuit is made an interval ter inductive loads and feature shorting  
before the second circuit. Another switch bar construction. A split contact version  
allows control of the two isolated circuits.  
Characteris tics : O.F. – Operating Force;  
R.F. – Release Force; P.T. – Pretravel;  
O.T. – Overtravel; D.T. – Differential Travel;  
O.P. – Operating Position.  
PIN PLUNGER  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F.  
R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
inche s  
O.P.*  
mm  
inche s  
newtons newtons  
ounce s  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
Make-before-break  
contact action  
10 Amps  
5,56  
20 max.  
2,22  
0,76  
0,13  
0,38  
.015  
15,9  
.625  
C
8
.030  
.005  
Dim. Dwg. Fig 5  
Unoperated  
Intermediate  
Fully  
Operated  
Intermediate  
Releas e  
Fully  
Releas ed  
Make-before-make  
contact action  
10 Amps  
9,73  
35 max.  
2,78  
10  
R
Dim. Dwg. Fig. 6  
*±0,38 mm  
± .015 in.  
Adjustable  
differential travel  
20 Amps  
3,10-5,56  
11-20  
2,78  
10  
0,25  
.010 at  
max.  
0,04-0,06  
.0015-.0025  
16,3  
.64  
Y
0,18  
.007 at max.  
s e tting  
s e tting  
Dim. Dwg. Fig. 4-A  
56 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
PIN PLUNGER —  
SPECIAL CIRCUITRY  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
Page 46  
O.F.  
R.F. min. P.T. max. O.T. min.  
D.T.  
mm  
inche s  
O.P.*  
mm  
inche s  
newtons newtons  
ounce s  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
Double-break, low  
15 Amps  
4,45-7,23  
1,11  
0,76  
0,13  
0,051-0,13  
15,9  
voltage DC applications  
T
16-26  
4
.030  
.005  
.002-.005  
.625  
As above, with  
2.5 inch lever  
15 Amps  
0,90  
3.25  
0,14  
.25  
5,56  
.219  
0,51  
2.54  
19,05±0,76  
.750±.030  
T
As above, with  
1.9 inch roller lever  
15 Amps  
1,25  
4.5  
0,21  
.75  
3.96  
.156  
0,38-1,91  
30,18±0,76  
Dim. Dwg. Fig. 8  
T
.015-.075 1.188±.030  
0,20-2,39 30,18±0,76  
.008-.030 1.188±.030  
As above, with  
1.05 inch roller lever  
15 Amps  
2,36  
8.5  
0,42  
1.5  
2,39  
.094  
T
Double-break, low  
25 Amps  
7,23-10,6  
2,78  
1,65  
0,25  
0,18-0,38  
16,3  
voltage DC applications  
M
26-38  
10  
.065  
.010  
.007-.015  
.640  
Dim. Dwg. Fig. 9  
MIL-S-8805 application  
requirements. (split  
contact)  
5 Amps  
U
4,45-7,23  
16-26  
1,11  
4
0,76  
.030  
0,13  
.005  
0,025-0,1  
.001-.004  
15,9  
.625  
As above, with  
2.50 inch lever  
5 Amps  
U
0,97  
3.5  
0,14  
.5  
5,56  
.219  
0,51-2,54  
.020-.100  
19,05±0,76  
.750±.030  
Dim. Dwg. Fig. 10  
As above, with  
1.9 inch roller lever  
5 Amps  
U
1,25  
4.5  
0,21  
.75  
3,96  
.156  
0,38-1,91  
.015-.075 1.188±.030  
30,18±0,76  
As above, with  
5 Amps  
1,95  
0,42  
2,39  
0,20-1,02  
30,19  
1.05 inch roller lever  
U
7
1.5  
.094  
.008-.040  
.188  
Except where stated * ±0,38 mm  
±.015 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 57  
Basic Switches  
BZ/BA Series  
Standard  
MOUNTING DIMENSIONS (For reference only)  
PIN PLUNGERS  
BZ/BM  
BA/BE  
Fig. 1  
Fig. 2  
Fig. 3  
Fig. 4  
Fig. 4-A  
PIN PLUNGERS — SPECIAL  
CIRCUITRY  
Fig. 5  
Fig. 6  
Fig. 7  
Fig. 8  
Fig. 9  
Fig. 10  
Mounting holes accept pins or screws of  
.139 (3,53 mm) diameter.  
58 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
MOUNTING DIMENSIONS (For reference only)  
OVERTRAVEL PLUNGERS  
Fig. 11  
Fig. 12  
Fig. 13  
Fig. 14  
Fig. 15  
Fig. 16  
*Fig. 17  
*Fig. 18  
*Fig. 19  
*Fig. 20  
* Threaded bus hings are 15/32-32ns .  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 59  
Basic Switches  
BZ/BA Series  
Standard  
MOUNTING DIMENSIONS (For reference only)  
STRAIGHT LEVERS  
Fig. 21  
Fig. 22  
Fig. 23  
Fig. 24  
Fig. 25  
Fig. 26  
FLEXIBLE LEAF ACTUATOR  
Fig. 33  
Fig. 34  
60 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
BZ/BA Series  
Standard  
MOUNTING DIMENSIONS  
ROLLER LEVERS  
Fig. 27  
Fig. 28  
Fig. 29  
Fig. 30  
Fig. 31  
Fig. 32  
FLEXIBLE ROLLER LEAF  
Mounting holes accept pins or screws of  
.139(3,53 mm) diameter.  
Fig. 35  
Fig. 36  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 61  
Basic Switches  
Auxiliary Actuators Standard Basic  
FEATURES  
GENERAL INFORMATION  
ɀ
ɀ
ɀ
ɀ
Additional overtravel  
Auxiliary actuators adapt the plunger-  
type standard basic switches to many ap-  
plication needs. Auxiliary actuators mini-  
mize the need for a large inventory of  
switch types. Actuators and switches are  
sold as separate items and must be or-  
dered separately. Mounting hardware is  
furnished with the actuator.  
Quick, easy installation  
Corrosion resistance  
MIL-S-8805 listed units  
NOTE: Switches s hown are not includ-  
ed with the actuator. All actuators are  
for us e with pin plunger types only ex-  
cept catalog lis ting J R.  
Characteris tics :  
O.T. — Overtravel;  
O.P. — Operating Position;  
F.P. — Free Position.  
ORDER GUIDE  
Us e  
Only  
With  
O.T. min.  
mm  
inches  
O.P.*  
mm  
inches  
F.P. max.  
mm  
inches  
Des cription  
Roller lever for ‘‘Splunger type  
BZ and DT switches only.  
Permits cam operation.  
BZ  
DT  
11.1  
.437  
44,45±3,18  
1.75±.125  
Fig. 1  
Adjustable roller lever. Tang on  
top of actuator can be bent to  
adjust O.P. and F.P.  
BZ  
BM  
11,1  
.437  
approx.  
31,75-41,15  
1.25-1.62  
39,6-43,7  
1.56-1.72  
BA  
BE  
9,53  
.375  
40,48  
1.594  
43,03  
1.812  
approx.  
approx.  
DT  
MT  
9,53  
.375  
39,6  
1.562  
46,03  
1.812  
approx.  
approx.  
Fig. 2  
Straight plunger. Panel mount.  
BZ  
BM  
4,78  
.188  
27,79  
.188  
29,4  
1.156  
BA  
BE  
3,96  
.156  
28,17  
1.109  
30,18  
1.188  
DT  
MT  
3,58  
.141  
27,79  
1.094  
30,18  
1.188  
Fig. 3  
Except where stated * ±1,14 mm  
±.045 in.  
Dimensions shown are for reference only.  
62 Honeywell ɀ MICRO SWITCH Sensing and Control  
For application help: call 1-800-537-6945.  
Basic Switches  
Auxiliary Actuators Standard Basics  
ORDER GUIDE  
Us e O.T. min.  
Only mm  
With Inches  
O.P.*  
mm  
Inches  
F.P. max.  
mm  
Inches  
Catalog  
Lis ting  
Des cription  
Fig. 4  
MC2711H  
BZ  
BM  
4,78  
.188  
28,98  
1.141  
29,4  
1.156  
Sealed straight plunger.  
Panel mount. Elastomer seal  
boot keeps out liquid splash  
and dirt. Furnished  
MCA2711H  
MCD2711H  
BA  
BE  
4,37  
.172  
27,38±0,76  
1.078±.030  
29,56  
1.156  
unassembled.  
DT  
MT  
3.58  
.141  
27,79  
1.094  
30,18  
1.188  
BZ  
BM  
3,18  
.125  
35,7  
1.406  
37,69  
1.484  
approx.  
Roller plunger. Panel mount.  
Roller parallel to long axis of  
the switch.  
Fig. 5  
BA  
BE  
3,18  
.125  
36,12  
37,69  
1.422  
1.484  
DT  
MT  
3,18  
.125  
35,7  
37,69  
1.406  
1.484  
BZ  
BM  
3,18  
.125  
35,7  
1.406  
37,69  
1.484  
approx.  
Cross roller plunger. Panel  
mount. Roller perpendicular  
to long axis of the switch.  
Fig. 6  
BA  
BE  
3,18  
.125  
36,12  
37,69  
1.422  
1.484  
DT  
MT  
3,18  
.125  
35,7  
37,69  
1.406  
1.484  
BZ  
20,62  
69,1  
70,64  
BM  
.812  
2.719  
2.781  
Fig. 7  
High overtravel plunger.  
Panel mount.  
BA  
BE  
19,84  
.781  
69,44  
2.734  
71,42  
2.812  
DT  
MT  
18,26  
.719  
69,1  
2.719  
71,42  
2.812  
Except where stated* ±1,14 mm  
±.045 in.  
For application help: call1-800-537-6945.  
Honeywell nsing and Control 63  
Basic Switches  
Accessories Standard Basics  
DIE CAST ZINC ENCLOSURES  
FEATURES  
Width of opening .74(18,8 mm)  
ɀ
ɀ
Protect switch from physical abuse  
Protect personnel from contact with ex-  
posed terminals  
ɀ
ɀ
Provide rugged mounting means  
1/2-14NPT internal thread conduit hub  
3PA1  
3PA2*  
*Width of base is 2.125 inches (54 mm)  
and mounting hole centers are 1.625  
inches (41,3 mm) apart.  
ORDER GUIDE  
Des cription  
Side mount enclosure–Can be mounted from either side through  
.140(3,55mm) dia. holes on 1(25,4mm) centers.  
Side mount enclosure–Can be mounted from either side through  
.140(3,55mm) dia. holes on 1(25,4mm) centers. 1/2-14 NPSM  
internal thread conduit hub.  
Flange mount enclosure—Switch is first secured in enclosure; two  
0.172(4,37mm) dia. holes in the flange accept # 8 machine screws  
for mounting on 1.625 (41,3mm) centers.  
Side mount enclosure—For use with actuator Fig. 2 page 58.  
PLASTIC TERMINAL ENCLOSURES  
FEATURES  
ɀ
ɀ
ɀ
Easy to use  
5PA1  
Screw and solder terminal versions  
Protect personnel from contact with  
exposed terminals  
5PA1 WITH SWITCH  
ASSEMBLY  
ORDER GUIDE  
Des cription  
For solder terminal switches  
For screw terminal switches  
5PA2  
For solder or screw terminal switches with auxiliary actuators  
assembled.  
Dimensions shown are for reference only.  
Switches are not included with  
enclosures.  
64 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
Accessories Standard Basics  
ADJ USTABLE MOUNTING BRACKETS  
FEATURES  
GENERAL INFORMATION  
ɀ
ɀ
ɀ
Sturdy plated steel construction  
Fast, easy screwdriver adjustment  
Can be used with all standard basic ening the locking screw, inserting  
switches screwdriver in the adjusting slot, and  
twisting.  
The operation point of a basic switch can  
be regulated up to .080(2 mm) by loos-  
a
ORDER GUIDE  
Des cription  
8MA1 WITH SWITCH  
ASSEMBLED  
Adjustable mounting bracket, adjustment slot on the left.  
Adjustable mounting bracket, adjustment slot on the right.  
MOUNTING DIMENSIONS  
A’ Dimension for  
BZ Type 3,6/.14  
BA Type 7,8/.31  
CONVERSION MOUNTING BRACKET  
FEATURES  
ɀ
Converts standard basic switches  
from side to top mount  
Corrosion resistant  
Snaps into switch mounting holes—  
without tools  
ɀ
ɀ
17MA1-B  
ORDER GUIDE  
Des cription  
Conversion mounting bracket.  
17MA1-B WITH SWITCH  
ASSEMBLED  
MOUNTING DIMENSIONS  
Switches are not included with bracket.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 65  
Basic Switches  
DT Series  
Double-pole Double-throw  
FEATURES  
AVAILABLE TERMINALS  
ɀ
Two independent single-pole double-  
throw circuits on one housing  
Design permitting several wiring  
combinations  
B6  
6-32 UNC .188 ⍯  
(No. 5 pan head screws)  
ɀ
ɀ
ɀ
Savings in space and weight  
Mounting interchangeability with type  
Z switches  
ɀ
ɀ
Temperature tolerance to +180°F  
(82°C)  
UL recognized, CSA certified  
A7  
4-40 UNC .125 ⍯  
Screws with lockwashers.  
Fiberglas insulator isolates  
terminals and prevents  
accidental shorting.  
ELECTRICAL RATING  
Ele ctrical Data and  
UL Code s  
Circuitry  
Double-pole  
double-throw  
J
10 amps, 125 or 250 vac;  
0.3 amp, 125 vdc; 0.15 amp,  
250 vdc.  
UL Code L59  
Characteris tics : O.F. — Operating Force; R.F. — Release Force;  
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;  
O.P. — Operating Position.  
DOUBLE-POLE  
DOUBLE THROW  
ORDER GUIDE  
O.F.  
max.  
newtons newtons  
R.F.  
min.  
P.T.  
max.  
mm  
D.T. max.  
min.  
mm  
Ele ctrical  
Data and  
UL Code  
O.T.  
mm  
O.P.*  
mm  
inche s  
De s cription  
ounce s  
ounce s  
inche s  
inche s  
inche s  
Pin plunger  
10 Amps  
3,34-5,56  
0,56  
1,91  
0,13  
1,02-1,52  
15,6  
J
12-20  
2
.075  
.005  
.040-.060  
.615±.015  
Dim. Dwg. Fig. 1  
Straight plunger  
10 Amps  
3,34-5,56  
12-20  
0,28  
1
1,91  
.075  
0,51  
.020  
1,02-1,52  
.040-.060  
28,2±0,38  
1.11±.015  
J
Dim. Dwg. Fig. 9  
Straight lever  
Reversed lever  
position  
10 Amps  
1,11-1,95  
4-7  
0,14  
0.5  
6,86  
.270  
0,25  
.010  
2,92-4,83  
.115-.190  
18,3  
.719  
J
Dim. Dwg. Fig. 3  
Straight lever  
10 Amps  
0,97-1,67  
0,28  
25,4  
1,57  
12,4-19,2  
21,8  
J
3.5-6  
1
1
.062  
.490-.755  
.859  
Except where stated * ±0,76 mm  
±.030 in.  
Dim. Dwg. Fig. 2  
66 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
DT Series  
Double-pole Double-throw  
ORDER GUIDE  
Ele ctrical O.F. max. R.F. min. P.T. max. O.T. min.  
D.T. max.  
mm  
inche s  
O.P.*  
mm  
inche s  
Data and  
UL Code s  
newtons  
ounce s  
newtons  
ounce s  
mm  
inche s  
mm  
inche s  
Re comme nde d For  
Roller lever  
10 Amps  
11,1  
1,11  
1,02  
0,13  
0,51-0,76  
31  
(centered steel roller)  
J
2.5 lbs .  
4
.040  
.005  
.020-.030  
1.219  
Dim. Dwg. Fig. 8  
1.03 inch (26,2mm) roller  
lever (steel roller)  
10 Amps  
2,5-3,89  
9-14  
0,83  
3
0,79  
.031  
4,95-7,75  
.195-.305  
30,2±0,38  
1.188±.015  
J
Dim. Dwg. Fig. 5  
Roller lever  
10 Amps  
2,5-4,17  
0,42  
3,3  
0,13  
1,27-2,16  
29,4  
Reversed lever position  
J
9-15  
1.5  
.130  
.005  
.050-.085  
1.156  
Dim. Dwg. Fig. 7  
Roller lever  
10 Amps  
1,53-2,64  
0,21  
4,45  
0,25  
2,16-3,43  
29,4  
Reversed lever position  
J
5.5-9.5  
.75  
.175  
.010  
.085-.135  
1.156  
Dim. Dwg. Fig. 6  
1.90 inch (48,3 mm) roller 10 Amps  
lever (steel roller)  
1,25-2,09  
4.5-7.5  
0,42  
1.5  
1,19  
.047  
9,27-14,4  
.365-.565  
31,8  
1.250  
J
Except where stated * ±0,76 mm  
±.030 in.  
Dim. Dwg. Fig. 4  
Auxiliary actuators see page 68-69.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 67  
Basic Switches  
DT Series  
Double-pole Double-throw  
MOUNTING DIMENSIONS (For reference only)  
PIN PLUNGER  
STRAIGHT LEVER  
Fig. 1  
Fig. 2  
STRAIGHT LEVER  
ROLLER LEVER  
Fig. 3  
Fig. 4  
68 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
DT Series  
Double-pole Double-throw  
MOUNTING DIMENSIONS (For reference only)  
ROLLER LEVER  
ROLLER LEVER  
Fig. 5  
Fig. 6  
ROLLER LEVER  
ROLLER LEVER  
Fig. 7  
Fig. 8  
STRAIGHT PLUNGER  
Fig. 9  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 69  
Basic Switches  
MT Series  
Magnetic Blow-out  
FEATURES  
GENERAL INFORMATION  
MT (single-pole double-throw) magnetic  
Mechanical life of 100,000 operations blow-out switches are designed to switch  
— 95% survival high capacity (125 and 250 VDC) sys-  
Temperature tolerance to +180°F tems. An integral magnet around the con-  
ɀ
ɀ
Arc resistant case  
ɀ
ɀ
ɀ
(82°C)  
tact gap protects the contacts by deflect-  
ing the arc. Vents between the cover and  
housing allow the hot gas to escape.  
These switches are designed for the con-  
trol of DC motors, solenoids, etc.  
Mounting interchangeability with  
switches  
Z
UL recognized  
AVAILABLE TERMINALS  
Solde r (No lis ting de s ignation)  
A28  
6-32NC .218Screws  
will accept up to # 12 wire.  
ELECTRICAL RATING  
Ele ctrical Data and  
UL Code s  
Circuitry  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
K
Rating established with  
switch non-polarized  
10 amps, 125 vac or vdc;  
1/4 hp, 125 vac or vdc.  
UL Code L 168  
Non-polarized:  
10 amps res. or 1/4 hp, 125 vdc;  
3 amps max. res. 250 vdc.  
Polarized*:  
10 amps res. or 1/2 hp, 125 vdc;  
3 amps max. res., 250 vdc.  
*To polarize, connect negative side of line to common terminal. To  
achieve the same effect, mount switch with brass screws, using a  
non-magnetic barrier (at least 1⁄  
mounting surface.  
4
thick) between the switch and  
Characteris tics : O.F. – Operating Force;  
R.F. – Release Force; P.T. – Pretravel;  
O.T. – Overtravel; D.T. – Differential Travel;  
O.P. – Operating Position.  
ORDER GUIDE  
Ele ctrical  
Data and  
UL Code s  
O.F.  
newtons  
ounce s  
R.F. min. P.T. max. O.T. min.  
D.T. max.  
mm  
inche s  
O.P.  
mm  
inche s  
newtons  
mm  
mm  
Re comme nde d For  
ounce s  
inche s  
inche s  
Pin plunger  
SPDT  
10 Amps  
3,34-5,0  
12-18  
1,39  
1,02  
0,13  
0,1-0,18  
.004-.007  
15,9±0,38  
.625±.015  
K
5
.04  
.005  
Dim. Dwg. Fig. 1  
70 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
MT Series  
Magnetic Blow-out  
ORDER GUIDE  
Ele ctrical O.F. max. R.F. min. P.T. max. O.T. min.  
D.T. max.  
mm  
inche s  
O.P.*  
mm  
inche s  
Data and  
UL Code s  
newtons  
ounce s  
newtons  
ounce s  
mm  
inche s  
mm  
inche s  
De s cription  
Straight lever  
10 Amps  
0,56  
0,14  
12,7  
1,19  
2,16  
19,1  
K
2
0.5  
0.5  
.047  
.085  
.750  
Dim. Dwg. Fig. 2  
1.90 inch (48,3mm) lever  
with hardened steel roller  
10 Amps  
0,76  
2.75  
0,07  
0.25  
8,89  
0.35  
0,79  
.031  
1,65  
.065  
30,2  
1.188  
K
1.03 inch (26,2mm) lever  
with hardened steel roller  
10 Amps  
1,25  
4.5  
0,28  
1
5,08  
.200  
0,38  
.015  
0,89  
.035  
31,3  
1.234  
K
Dim. Dwg. Fig. 3  
1.95 inch (49,5mm)  
flexible leaf  
10 Amps  
3,34  
12  
0,28  
1
1,52  
.060  
max.  
19,1  
.750  
K
Dim. Dwg. Fig. 4  
1.82 inch (46,2mm)  
flexible leaf with hardened  
steel roller  
10 Amps  
3,34  
12  
0,28  
1
1,52  
.060  
max.  
30,2  
1.188  
K
Dim. Dwg. Fig. 5  
Except where stated * ±0,76 mm  
±.030 in.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 71  
Basic Switches  
MT Series  
Magnetic Blow-out  
MOUNTING DIMENSIONS (For reference only)  
PIN PLUNGER  
STRAIGHT LEVER  
Fig. 1  
Fig. 2  
ROLLER LEVER  
FLEXIBLE LEAF  
Fig. 3  
Fig. 4  
FLEXIBLE ROLLER LEAF  
Fig. 5  
Mounting holes accept pins or screws of  
.139 (3,53 mm) diameter.  
72 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
3MN Series  
Double-break  
FEATURES  
GENERAL INFORMATION  
3MN switches are for use with limit or con-  
Power load switching capability up to trol mechanisms on machine tools,  
ɀ
ɀ
.080 inch minimum overtravel  
15 amperes  
presses or other industrial equipment.  
ɀ
ɀ
Motor handling capacity of 1 horse-  
power at 240 vac.  
Long mechanical life of 10,000,000 cy- mounting.  
cles95% survival  
These switches provide easy gang  
ɀ
ɀ
Arc resistant plastic  
The terminals of double-break switches  
More space between terminals to re- must be wired to identical voltage sourc-  
duce possibility of shorting  
# 8 Terminal screws  
UL recognized, CSA certified  
es and the same polarity. The loads  
should be on the same sides of the lines.  
ɀ
ɀ
ELECTRICAL RATING  
Ele ctrical Data and  
UL Code s  
Circuitry  
V Motor Control  
15 amps, 120, 240, 480 or 600 vac;  
1/2 hp, 120 vac; 1 hp, 240 vac;  
0.8 amp, 115 vdc; 0.4 amp,  
230 vdc.  
Two-circuit  
double-break  
Characteris tics : O.F. — Operating Force; R.F. — Release Force; P.T.  
— Pretravel; O.T. – Overtravel; D.T. — Differential Travel; O.P. — Operating  
Position.  
ORDER GUIDE  
R.F.  
min.  
P.T.  
max.  
mm  
O.T.  
min.  
mm  
Ele ctrical  
Data and  
O.F.  
D.T.  
mm  
O.P.* max.  
mm  
newtons newtons  
De s cription  
UL Code s ounce s  
ounce s  
inche s  
inche s  
inche s  
inche s  
For most  
applications  
15 Amps  
3,34-5,56  
12-20  
1,67  
6
1,52  
.060  
2,03  
.080  
0,38-0,63  
.015-.025  
2,16  
.085  
V
Lower force  
15 Amps  
1,95-3,1  
1,11  
1,52  
2,03  
0,38-0,63  
2,16  
V
7-11  
4
.060  
.080  
.015-.025  
.085  
Dim. Dwg. Fig. 1  
* ±0,38 mm  
±.015 in.  
MOUNTING DIMENSIONS (For reference only)  
Fig. 1  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 73  
Basic Switches  
6AS Series  
Tandem Switch Assemblies  
FEATURES  
GENERAL INFORMATION  
6AS switches are two standard basic  
Choice of circuitries and electrical switches ganged together and actuated  
ɀ
ɀ
Variety of actuators  
ratings  
Choice of terminations  
by a single actuator. Operating character-  
istics will depend on the type of individual  
ɀ
ɀ
Field adjustable operating point on one switches and actuators.  
or both basic switches  
ELECTRICAL RATING  
Ele ctrical Data and  
UL Code s  
Circuitry  
Single-pole  
double-throw  
unless  
otherwise noted  
in order guide  
A
G
15 amps, 125, 250 or 480 vac;  
1/8 hp, 125 vac; 1/4 hp, 250 vac;  
1/2 amp, 125 vdc; 1/4 amp,  
250 vdc.  
UL Code L96  
Single-pole  
double-throw  
unless  
20 amps, 125, 250 or 480 vac;  
10 amps, 125 vac ‘‘L’’ (tungsten  
lamp load);  
otherwise noted  
in order guide  
1 hp, 125 vac; 2 hp, 250 vac;  
1/2 amp, 125 vdc; 1/4 amp,  
250 vdc.  
UL Code L23  
Characteris tics : O.F. – Operating Force; R.F. – Release Force; P.T. – Pre-  
ORDER GUIDE  
travel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position.  
Le ve r  
Le ngth  
mm  
O.F.  
max.  
newtons newtons  
ounce s  
R.F.  
min.  
O.T.  
min.  
mm  
D.T.  
max.  
mm  
Ele ctrical  
Data and  
O.P.*  
mm  
inche s  
Type  
De s cription  
inche s Te rminals UL Code s  
ounce s  
inche s inche s  
Centered lever. Adjustment over  
58,72  
15 Amps  
2,22  
0,14  
0,51  
2,77  
18,29  
both switches.  
2.312  
Solde r  
Solde r  
A2  
A
8
0.5  
.020  
.109  
.720 adj.  
Short lever. Adjustment over  
20,47  
.806  
15 Amps  
3,34  
12  
0,83  
3
0,25  
.010  
3,96  
.156  
18,24  
.718 max.  
switch D.  
A
Centered lever. Adjustment over  
32,26  
1.270  
20 Amps  
3,89  
14  
1,11  
4
1,02  
.040  
18,67  
.735  
Dim. Dwg. Fig. 1  
switch D.  
G
Unless otherwise noted * ±0,76 mm  
±.030 in.  
74 Honeywell Sensing and Control  
For application help: call1-800-537-6945.  
Basic Switches  
6 AS Series  
Tandem Switch Assemblies  
ORDER GUIDE  
Le ve r  
Le ngth  
mm  
O.F.  
max.  
newtons newtons  
R.F.  
min.  
O.T.  
min.  
mm  
D.T.  
max.  
mm  
Ele ctrical  
Data and  
O.P.*  
mm  
Type  
De s cription  
inche s Te rminals UL Code s  
ounce s  
ounce s  
inche s  
inche s  
inche s  
Centered lever.  
Adjustment over  
switch D.  
30,56  
1.203  
15 Amps  
2,22  
8
0,14  
0.5  
0,51  
.020  
2,77  
.109  
29,77  
1.172  
Solde r  
Solde r  
A2  
A
Centered lever.  
Adjustment over both  
switches.  
30,56  
1.203  
15 Amps  
2,22  
8
0,14  
0.5  
0,51  
.020  
2,77  
.109  
29,77  
1.172 adj.  
A
Lever over switch C.  
Adjustment over  
switch D.  
30,56  
1.203  
15 Amps  
2,22  
8
0,14  
0.5  
0,51  
.020  
2,77  
.109  
29,77  
1.172  
A
Lever and adjustment 30,56  
15 Amps  
2,22  
8
0,14  
0.5  
0,51  
.020  
2,77  
.109  
29,77  
1.172  
over switch D.  
1.203  
A2  
A2  
A
Centered lever.  
Adjustment over  
switch D.  
30,56  
1.203  
20 Amps  
3,89  
14  
1,11  
4
1,02  
.040  
3,96  
.156  
30,96±1,14  
1.219±.045  
G
Centered lever.  
Adjustment over  
switch D.  
27,25  
1.073  
25 Amps  
30,96±1,14  
1.219±.045  
T
M
Centered lever.  
Adjustment over  
switch D.  
30,56  
1.203  
25 Amps  
3,89  
14  
1,11  
4
1,02  
.040  
3,96  
.156  
30,96±1,14  
1.219±.045  
Dim. Dwg. Fig. 2  
A2  
H
Centered leaf. No  
adjustment. Switches  
operate within .030  
of each other.  
38,35  
1.51  
15 Amps  
0,76-1,52  
.030-.060  
A2  
A
Dim. Dwg. Fig. 3  
Unless otherwise noted * ±0,76 mm  
±.030 in.  
MOUNTING DIMENSIONS (For reference only)  
STRAIGHT LEVER  
ROLLER LEVER  
LEAF  
Fig. 1  
Fig. 2  
Fig. 3  
Mounting holes accept pins or screws of  
.139 (3,53 mm) diameter.  
For application help: call1-800-537-6945.  
Honeywell Sensing and Control 75  

相关型号:

UM10A10C01

Basic Switches

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10A70A01

Snap Acting/Limit Switch, SPDT, Momentary, 0.7mm, Solder Terminal, Roller Lever Actuator, Through Hole-straight

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10A70C01

Snap Acting/Limit Switch, SPDT, Momentary, 3.6mm, Solder Terminal, Roller Lever Actuator, Through Hole-straight

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B

0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
YFW

UM10B-10

SINGLE PHASE GLASS PASSIVATED BRIDGE RECTIFIERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MDD

UM10B10A01

Basic Switches

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B10B01

Basic Switches

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B10C01

Basic Switches

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B10D01

Basic Switches

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B10J01

Snap Acting/Limit Switch, SPDT, Momentary, 11mm, Solder Terminal, Flat Lever Actuator, Through Hole-straight

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B40B01

Snap Acting/Limit Switch, Momentary, 3mm, Solder Terminal, Flat Lever Actuator, Through Hole-straight

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL

UM10B40D01

Snap Acting/Limit Switch, Momentary, 4.5mm, Solder Terminal, Flat Lever Actuator, Through Hole-straight

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
HONEYWELL