XCA501AN [HONEYWELL]

Peizoresistive Sensor, Absolute, 0Psi Min, 1Psi Max, 1-6V, Rectangular, Through Hole Mount;
XCA501AN
型号: XCA501AN
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Absolute, 0Psi Min, 1Psi Max, 1-6V, Rectangular, Through Hole Mount

传感器 换能器
文件: 总4页 (文件大小:158K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Pressure Sensors  
Fixed Output, Amplified  
Calibrated with Ratiometric Output Voltage  
XCA Series  
FEATURES  
·
Precise Temperature  
Compensation  
·
·
·
Low Cost  
High Performance  
Gage, Absolute and  
Differential Versions  
Constant Voltage  
Excitation  
·
·
·
Calibrated Output  
Ratiometric Output Voltage  
TYPICAL APPLICATIONS  
·
·
Ventilators  
The XCA Series of pressure sensors use state of the art silicon  
Continuous Positive  
Airway Pressure (CPAP)  
Systems  
micromachined pressure sensors in conjunction with stress free packaging  
techniques to provide highly accurate, amplified, calibrated and  
temperature compensated pressure sensors for the most demanding  
applications.  
When operated from a fixed 5.0 Vdc supply, the XCA gage and absolute  
sensors provide a 0.25 Vdc to 4.25 Vdc output (4.0 Vdc Span). The XCA5  
Series offers an industry standard 1-6 Vdc output (5 Vdc Span) when  
operated from a fixed 8.0 Vdc supply.  
·
·
·
·
Audiometers  
Air Compressors  
Chemical Analyzers  
Variable Air Volume (VAV)  
Controllers  
·
Airflow  
All other features are the same for the entire family, incorporating stress  
isolation and factory calibration to achieve optimum accuracy in this  
industry standard package.  
WARNING  
PERSONAL INJURY  
WARNING  
DO NOT USE these products  
as safety or emergency stop  
devices or in any other  
MISUSE OF DOCUMENTATION  
·
The information presented in this product sheet is for reference only. Do  
not use this document as product installation information.  
Complete installation, operation, and maintenance information is  
provided in the instructions supplied with each product.  
application where failure of the  
product could result in  
personal injury.  
·
Failure to comply with these instructions could result in death or serious  
injury.  
Failure to comply with these  
instructions could result in  
death or serious injury.  
Sensing and Control  
Pressure Sensors  
XCA Series  
Calibrated with Ratiometric Output Voltage  
XCA4 Electrical Specifications at 5 Vdc Excitation, XCA5 Electrical Specifications at 8 Vdc Excitation, 25 °C*  
Min.  
Typ.  
Max.  
Units  
Excitation Voltage  
3.0  
5.0  
16  
V
Null XCA4 (except Differential)  
Null XCA4 Differential  
0.15  
2.20  
0.95  
2.45  
3.90  
±1.95  
4.90  
±2.45  
--  
0.25  
2.25  
1.00  
3.50  
4.00  
±2.00  
5.00  
±2.50  
±0.30  
±0.1  
±0.6  
±0.6  
--  
0.35  
2.30  
1.05  
3.55  
4.10  
±2.05  
5.10  
±2.55  
±0.50  
--  
V
V
Null XCA5  
V
Null XCA5 Differential  
V
Span XCA4 (except Differential)  
Span XCA4 Differential, changes with ± pressure applied  
Span XCA5  
V
V
V
V
Span XCA5 Differential, changes with ± pressure applied  
Linearity, Hysteresis Error***  
%Span  
%Span  
%Span  
%Span  
Repeatability  
--  
Temp. Change Span (0 °C to +50 °C [+32 °F to +122 °F])**  
Temp. Change Offset (0 °C to +50 °C [+32 °F to +122 °F])**  
Operating Temperature  
--  
±1.0  
±1.0  
+85  
+125  
50  
--  
-25  
-40  
°C  
°C  
psi  
FS  
FS  
Storage Temperature  
--  
Common Mode Pressure  
Proof pressure (times span pressure)****  
Burst pressure (times span pressure)****  
--  
--  
3X  
5X  
--  
--  
*Note 1:  
All parameters are measured at 5.0 volt excitation for XCA4 and at 8.0 volt excitation for XCA5, for the nominal full  
scale pressure and room temperature unless otherwise specified. Pressure measurements are with positive pressure  
applied to Port 2 or Vacuum to Port 1. For absolute devices, pressure is applied to Port 2.  
Shift is relative to 25 °C  
Measured at ½ full scale rated pressure using BFSL  
Proof pressure should not exceed 200 psi and burst pressure should not exceed 300 psi  
**Note 2:  
***Note 3:  
****Note 4:  
Equivalent Circuit  
Pinout  
1. V Excitation  
2. Common  
3. V Output  
4. V Offset  
2 Honeywell · Sensing and Control  
Pressure Sensors  
XCA Series  
Calibrated with Ratiometric Output Voltage  
MOUNTING DIMENSIONS (for reference only) mm/in  
XCA SERIES, XCA MOLDED PACKAGE  
APPLICATION INFORMATION  
MEDIA COMPATIBILITY, WETTED MATERIALS  
(Apply clean air dry only)  
PRESSURE COMPATIBILITY  
XCA4 Gage and Absolute: Measures gage pressure  
only with positive pressure to port 2. There will be a  
small output voltage between the actual offset voltage  
Port 2  
P2 Port: Media must be  
compatible with nylon housing,  
epoxy adhesive and silicon. Port  
and ground proportional to vacuum if applied to port 2.  
XCA4 Differential: Measures differential pressure with  
positive pressure to port 2 and negative pressure,  
vacuum, to port 1. The offset is set to 2.25 volts at 0  
psid. It will change slightly with changes in common  
mode (line) pressure. The maximum common mode or  
line pressure is 50 psi except for 5 psi and less where  
the maximum is 190 psi.  
not used for absolute devices.  
Port 1  
P1 Port: Dry Gases Only. Media  
must be compatible with epoxy  
based adhesive. Dead volume of  
0.0102 cubic inches.  
XCA5 Gage and Absolute: Measures gage pressure  
only with positive pressure to port 2. There will be a  
small output voltage between the actual offset voltage  
and ground proportional to vacuum if applied to port 2.  
Honeywell · Sensing and Control 3  
Pressure Sensors  
XCA Series  
Calibrated with Ratiometric Output Voltage  
XCA SERIES ORDER GUIDE  
(Not all product combinations are released.)  
D
N
XCA  
L
4
01  
Package Type  
N - Plastic  
Series  
XCA - compensated and calibrated, mV  
Pressure Measurement  
L - Low Pressure (in H2O)  
No Character - Indicates Pressure (psi)  
Pressure Reference  
G - Gage  
D - Differential  
A - Absolute > 5 psi  
Output Voltage  
4 - Calibrated 4.0 Volt Output  
5 - Calibrated 5.0 Volt Output  
Pressure Reference1  
10 in H2O  
01, 05, 15, 30, 60, 100, 150 psi  
NOTE 1: The 10 in H2O and 1 psi range exhibit a slight sensitivity to change in position (gravity sensitivity).  
WARRANTY/REMEDY  
Specifications may change  
without notice. The information  
we supply is believed to be  
accurate and reliable as of this  
printing. However, we assume no  
responsibility for its use.  
For application assistance,  
current specifications, or name of  
the nearest Authorized  
Distributor, contact a nearby  
sales office. Or call:  
Honeywell warrants goods of  
its manufacture as being free of  
defective materials and faulty  
workmanship. Contact your local  
sales office for warranty  
1-800-537-6945 USA  
information. If warranted goods  
are returned to Honeywell during  
the period of coverage,  
Honeywell will repair or replace  
without charge those items it  
finds defective. The foregoing is  
Buyer’s sole remedy and is in  
lieu of all other warranties,  
expressed or implied,  
While we provide application  
assistance personally, through  
our literature and the Honeywell  
web site, it is up to the customer  
to determine the suitability of the  
product in the application.  
1-800-737-3360 Canada  
1-815-235-6847 International  
FAX  
1-815-235-6545 USA  
INTERNET  
www.honeywell.com/sensing  
info.sc@micro.honeywell.com  
including those of  
merchantability and fitness for  
a particular purpose.  
Sensing and Control  
Honeywell  
11 West Spring Street  
Freeport, Illinois 61032  
Printed with Soy Ink  
on 50% Recycled Paper  
Copyright ã 1997- 2001 by Honeywell Data Instruments Inc. All rights reserved.  
008051-2-EN IL50 GLO 0801 Printed in USA  
www.honeywell.com/sensing  

相关型号:

XCA501DN

Peizoresistive Sensor, Differential, 0Psi Min, 1Psi Max, 3.50-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA501GN

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA505AN

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA505DN

Peizoresistive Sensor, Differential, 0Psi Min, 5Psi Max, 3.50-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA505GN

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA5100AN

Peizoresistive Sensor, Absolute, 0Psi Min, 100Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA5100DN

Peizoresistive Sensor, Differential, 0Psi Min, 100Psi Max, 3.50-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA5100GN

Peizoresistive Sensor, Gage, 0Psi Min, 100Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA5150AN

Peizoresistive Sensor, Absolute, 0Psi Min, 150Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA5150GN

Peizoresistive Sensor, Gage, 0Psi Min, 150Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA515GN

Peizoresistive Sensor, Gage, 0Psi Min, 15Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL

XCA530AN

Peizoresistive Sensor, Absolute, 0Psi Min, 30Psi Max, 1-6V, Rectangular, Through Hole Mount
HONEYWELL