ZLCC31A1AR [HONEYWELL]

Global Limit Switches; 全球限位开关
ZLCC31A1AR
型号: ZLCC31A1AR
厂家: Honeywell    Honeywell
描述:

Global Limit Switches
全球限位开关

开关 限位开关
文件: 总6页 (文件大小:505K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ZLS Series Global Limit Switches  
STANDARDS  
IEC 947-1 explains the general rules relating to Low-voltage  
GENERAL INFORMATION  
ZLS series limit switches are specifically designed for world-  
wide applications and is supported by Honeywell global  
resources for sales and after sales service.  
ZLS series limit switches are designed to the latest IEC  
standard are available and include a wide range of EN50041  
and EN50047 type switches. Miniature EN50047 limit  
switches are available in metal and double insulated  
enclosures and a metal enclosed 3-cable entry version  
(EN50047 mounting compatible) is also offered.  
Standard ZLS switch circuit variations include 2 and 3-circuit  
versions with forced disconnect mechanism. ZLS includes  
features to make quick installation easier and safer.  
Customers will benefit from Honeywell’s vast experience in  
serving world industries over many years.  
switchgear and controlgear. The purpose of this standard is to  
harmonize as much as possible the product performance and  
test requirements for equipment where the rated voltage does  
not exceed 1,000 VAC or 1,500 VDC.  
IEC 947-5-1 is part 5 of the general rules which relates to  
Controlcircuit devices and switching elements. Also within this  
part there is a section which considers Special Requirements  
For Control Switches With Positive Opening Operation. Any  
control switch which has this positive opening operation and  
conforms to these special requirements will be marked on the  
outside of the product with this symbol:  
The Contact Element Form defines the configuration of the  
contacts and the number of contacts within the switch. e.g.  
Form Za – both contact elements have the same polarity.  
Form Zb – the two contact elements are electrically separated.  
Most ZLS versions are interchangeable with almost all other  
makes of EN50041/47 switches.  
The Utilization Category defines the type of current carried (AC)  
Alternating current, (DC) Direct current and the typical application  
in which the switch is used e.g.  
AC15 – Control of Electromagnetic Loads (less than 72VA)  
DC13 – Control of electromagnets.  
TYPICAL APPLICATIONS  
Machine tools: metal fabrication equipment, presses,  
transfer lines and special machinery  
Material handling equipment: conveyors, elevators, cranes  
and hoists  
The contact rating Designation relates to the utilization  
categories and defines the conventional thermal current lth (A),  
rated operational current le (A) at rated operational voltages Ue  
Packaging machinery and process equipment  
Textile machinery  
and the VA rating e.g.  
A600 – The ‘‘A’’ denotes the maximum VA rating (AC) and the ‘‘600’’  
Construction machinery and equipment, vehicles and lift  
trucks  
denotes the maximum rated (AC) voltage.  
Q300 – The ‘‘Q’’ denotes the maximum VA rating (DC) and the ‘‘300’’  
denotes the maximum rated (DC) voltage.  
FEATURES  
Designed to the new IEC standard for world-wide  
applications  
Positive opening of normal closed contact meets IEC947-  
5-1-3 safety standard.  
These IEC standards have been adopted by CENELEC (The  
European Commitee for Electrotechnical Standardization) and  
have been identified by replacing IEC with EN 60 e.g.  
IEC 947-5-1 then becomes EN 60947-5-1.  
UL, CSA, and CE  
Sealing up to IP/65/ IP 67  
International conduit sizes  
Design for ease of installation  
Eleven basic switch versions, Wide choice of actuators  
CENELEC has defined the dimensions and characteristics of two  
types of limit switch in the standards EN 50041 and EN 50047.  
These standards relate to Low voltage switchgear and  
controlgear for industrial use and define the enclosure  
dimensions, the operating point for various head actuators, the  
earth terminal requirement, the terminal marking and the  
minimum degree of IP protection.  
ZLS Series Global Limit Switches  
How to read and understand the bar chart  
Look at Figures A and B as examples. Actuator type  
The following example relates to a unit which has a snap action  
basic and which has a roller pin plunger actuator i.e. ZLCB01C.  
When reading these bar charts follow these rules:  
1. Check what type of actuator was used to test the product, this is  
on the drawings which show the head style available. It will be one  
of two types:  
used for test is the linear Cam travel type (b) shown  
left. The start point is at the arrow marked ‘‘A’’ (See fig.  
B). This shows the free position to be 5.3mm from the  
vertical center line of the unit. At this stage there is a  
circuit between the terminals 21-22 but no circuit  
between terminals  
a) Vertical travel plunger  
13-14. The unit can be actuated until it reaches the  
operating position which is 10.5 mm from the center  
line – a travel distance of 10.5 – 5.3 =5.2 mm from the  
free position. At this point the circuit arrangement  
changes – no circuit between 21-22 but making a  
circuit between 13-14. If, however, the contacts of  
terminals 21-22 weld together and will not separate, a  
mechanical safety feature will take effect if the switch is  
travelled past the point from which positive opening is  
assured, 13.9 mm. Actuator can continue to travel to  
the end position (O.T. Overtravel Position) at total  
travel position 17.3mm. As the switch returns it  
reaches the release position at 8.9 mm from the center  
line. The circuit will change back to the original state  
and the difference between the operating position and  
the release position gives what is known as the  
differential travel i.e. 10.5 – 8.9 = 1.6 mm. The asterisk  
(*) indicates the point from which the positive opening  
is assured.  
b) Linear cam travel  
2. Start reading from top left of figure B, at the arrow labeled ‘‘A’’.  
3. Follow the black arrows and the black strip on the chart. The  
black strip indicates that there is a circuit between the terminals  
whose numbers are shown on the left and when white there is no  
circuit.  
All dimensions are in mm/(inches).  
Figure A  
Figure B  
ZLA  
ZLB  
ZLC  
ZLD  
ZLE  
ZLF  
Standard  
Enclosure  
EN 50041  
EN 50041  
EN 50047  
EN 50047  
EN 50047  
EN 50047  
3-cable entry  
2-cable entry  
Metal  
Plastic  
Metal  
Plastic  
Metal  
Plastic  
Operating  
Temperature  
-25~ +120°C  
-25~ +80°C  
-25~ +80°C  
-25~ +80°C  
-25~ +80°C  
-25~ +80°C  
Humidity  
<95%RH  
<95%RH  
<95%RH  
<95%RH  
<95%RH  
<95%RH  
Shock/Vibration  
Operating Speed  
10 g / 50 g  
0.05mm-2m/s  
10 g / 50 g  
0.05mm-2m/s  
10 g / 50 g  
10 g / 50 g  
0.05mm-2m/s  
10 g / 50 g  
0.05mm-2m/s  
10 g / 50 g  
0.05mm-2m/s  
0.05mm-  
2m/s  
Operating  
Frequency  
120 ops/min  
120 ops/min  
120 ops/min  
120 ops/min  
120 ops/min  
120 ops/min  
Contact Resistance  
Degree of Protection  
Electrical Rating  
<25mΩ  
<25mΩ  
<25mΩ  
<25mΩ  
<25mΩ  
<25mΩ  
IP67  
IP65  
IP67  
IP65  
IP67  
IP65  
AC15 A600  
DC13 Q300  
AC15 A300  
DC13 Q300  
AC15 A300  
DC13 Q300  
AC15 A300  
DC13 Q300  
AC15 A600  
DC13 Q300  
AC15 A300  
DC13 Q300  
Dielectric Strength  
Mechanical Life  
Electrical Life  
2500V  
107  
2500V  
107  
2500V  
107  
2500V  
107  
2500V  
107  
2500V  
107  
5X105  
5X105  
5X105  
5X105  
5X105  
5X105  
ZLS Series Global Limit Switches  
Mounting Dimensions  
<ZLA>  
<ZLB>  
<ZLD>  
<ZLC>  
<ZLF>  
<ZLE>  
ZLS Series Global Limit Switches  
Selection Guide  
R
A1B  
01  
ZLA  
A
conduit  
sizes  
Pull Reset  
Enclosure Type  
Contact block type  
(see below)  
Acutator Style  
(see next page)  
ZLA  
ZLB  
ZLC  
EN50041(Metal)  
EN50041(Plastic)  
A
C
1/2 NPT  
M20  
EN50047(Metal)  
ZLD  
ZLE  
ZLF  
EN50047(Plastic)  
3-cable entry (Metal)  
2-cable entry (Plastic)  
Contact Block Type  
01  
03  
06  
07  
04  
1NO/1NC  
Snap Action  
1NO/1NC  
Break Before Make  
2NO  
Slow Action  
2NC  
Slow Action  
1NO/1NC  
Make Before Break  
34  
33  
31  
35  
32  
30  
2NC/1NO  
2NC/1NO  
2NC/1NO  
Break Before Make  
1NC/2NO  
Make Before Break  
3NO  
Slow Action  
3NC  
Slow Action  
Break Before Make Make Before Break  
ZLS Series Global Limit Switches  
ZLA, ZLB  
ZLC, ZLD  
ZLE, ZLF  
Fixed Side Rotary  
Lever  
A1A (plastic roller)  
A1B (metal roller)  
Adj. Side Rotary  
Lever  
A2A (plastic roller)  
A2B (metal roller)  
Adj. Side Rotary  
Rod  
A4J (Metal Rod)  
50mm Side Rotary  
Lever  
A1Y (Fixed)  
A2Y (Adjustable)  
Yoke Lever  
V
Spring Coil: E7B  
Plastic Rod, Spring  
Coil: E6A  
Cat Whisker,  
Spring Coil: E5G  
ZLS Series Global Limit Switches  
ZLA, ZLB  
ZLC, ZLD  
ZLE, ZLF  
B
(Plunger)  
C
(Roller  
Plunger)  
D
(Roller  
Lever)  
F
(Vertical  
Roller Lever)  
F1  
(Roller  
Lever)  

相关型号:

ZLCC32A1AR

Global Limit Switches
HONEYWELL

ZLCC33A1AR

Global Limit Switches
HONEYWELL

ZLCC34A1AR

Global Limit Switches
HONEYWELL

ZLCC35A1AR

Global Limit Switches
HONEYWELL

ZLDA01A1AR

Global Limit Switches
HONEYWELL

ZLDA03A1AR

Global Limit Switches
HONEYWELL

ZLDA04A1AR

Global Limit Switches
HONEYWELL

ZLDA06A1AR

Global Limit Switches
HONEYWELL

ZLDA07A1AR

Global Limit Switches
HONEYWELL

ZLDA30A1AR

Global Limit Switches
HONEYWELL

ZLDA31A1AR

Global Limit Switches
HONEYWELL

ZLDA32A1AR

Global Limit Switches
HONEYWELL