HFD16/12-ZFH-3N [HONGFA]

SUBMINIATURE SIGNAL RELAY;
HFD16/12-ZFH-3N
型号: HFD16/12-ZFH-3N
厂家: HONGFA TECHNOLOGY    HONGFA TECHNOLOGY
描述:

SUBMINIATURE SIGNAL RELAY

文件: 总3页 (文件大小:469K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SUBMINIATURE SIGNAL RELAY  
HFD16  
Features  
8A switching capability  
UL insulation system: Class F available  
Plastic sealed and flux proofed types available  
Standard PCB layout  
File No.: E133481  
Product in accordance to IEC 60335-1 available  
File No.: R50075326  
RoHS compliant  
COIL  
CONTACT DATA  
Contact arrangement  
1C  
Coil power  
H type: 200mW;  
100m max.  
0.1A 30mVDC,  
and AgSnO2:1A 30mVDC)  
(AgNi gold-plated specifications:  
Contact resistance1)  
Contact material  
AgNi non gold-plated specifications  
COIL DATA  
at 23  
AgNi, AgSnO2  
Contact rating  
(Res. load)  
3A 30VDC  
1A 125VAC  
Pick-up Drop-out  
Coil Resistance  
x (1 10%)  
Max.  
Voltage2)  
VDC  
Nominal  
Voltage  
VDC  
Voltage Voltage  
VDC1)  
max.  
VDC1)  
min.  
Max. switching voltage  
Max. switching current  
250VAC / 220VDC  
8A(30VDC)  
H
2.4  
3
1.80 0.24  
2.25 0.3  
3.38 0.45  
3.12  
3.90  
5.85  
6.50  
6.63  
11.7  
15.6  
23.4  
31.2  
28.8  
45.0  
101.3  
120  
750VA / 90W  
Max. switching power  
Min. applicable load  
5V 1mA(Suitable for AgNi gold-plated specifications)  
4.5  
5
1 x 107OPS  
Mechanical endurance  
Electrical endurance  
1x105OPS(NO:AgNi85 1son9soff3A30VDC)  
1x104OPS(NO:AgNi85 ,1son 9s off,5A125VAC)  
3.75  
4.5  
0.5  
0.6  
0.9  
1.2  
1.8  
2.4  
6
180  
Notes: 1) The data shown above are initial values.  
2)Min. applicable load is reference value. Please perform the  
confirmation test with the actual load before production since  
reference value may change according to switching frequencies,  
environmental conditions and expected contact resistance and  
reliability.  
9
6.75  
9.00  
13.5  
18.0  
400  
12  
18  
24  
700  
1620  
2800  
CHARACTERISTICS  
Insulation resistance  
1000M (at 500VDC)  
1100VAC 1min  
750VAC 1min  
Notes: 1) The data shown above are initial values.  
2) Maximum voltage refers to the maximum voltage which relay  
coil could endure in a short period of time.  
between coil & contacts  
between open contacts  
Dielectric  
strength  
SAFETY APPROVAL RATINGS  
Operate time (at rated voltage.)  
Release time (at rated voltage.)  
5ms max.  
5ms max.  
5A 125VAC  
Functional  
Shock resistance  
1A 125VAC85oC  
98m/s2  
980m/s2  
AgNi  
3A 30VDC85oC  
Destructive  
UL/CUL  
1A 125VAC 85oC  
3A 30VDC85oC  
TV-1 125VAC  
Functional  
10Hz to 55Hz 1.5mm DA  
10Hz to 55Hz 3.3mm DA  
Vibration resistance  
AgSnO2  
Destructive  
Surge withstand voltage  
1000V(FCC part 68)  
1500V(Telecordia)  
5% to 85% RH  
-40 to 85  
between open contacts(10/160 µ s)  
between coil & contacts(2/10 µ s)  
1A 250VAC  
1A 125VAC, 85oC  
3A 30VAC, 85oC  
3A 250VAC  
1A 250VAC85oC  
3A 30VAC, 85oC  
1(1) 250VAC  
AgNi  
Humidity  
Ambient temperature  
Termination  
TÜV  
PCB (DIP)  
Approx. 4g  
AgSnO2  
Unit weight  
Plastic sealed,  
Flux proofed  
Construction  
3A 250VAC  
Notes: 1) All values unspecified are at room temperature.  
2) Only typical loads are listed above. Other load specifications  
can be available upon request.  
Notes: 1) The data shown above are initial values.  
2) UL insulation system: Class F.  
HONGFA RELAY  
2020 Rev. 1.00  
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED  
45  
ORDERING INFORMATION  
24  
HFD16/  
-Z F H -3 N (XXX)  
Type  
Coil voltage  
2.4,3, 4.5, 5, 6, 9, 12, 18, 24 VDC  
Contact arrangement Z:1 Form C  
Construction  
Coil power  
F: Flux proofed  
Nil: Plastic sealed  
H: High sensitive (200mW)  
Contact material 3: AgNi  
T: AgSnO2  
Nil: gold plated3)  
N: No gold plated  
Contact plating  
Special code1)  
XXX: Customer special requirement  
Nil: Standard  
Notes: 1) The customer special requirement express as special code after evaluating by Hongfa.  
2) The standard size of this pruduct tube package is 409mm, Any special requirement needed, please contact us for more details.  
3) Only suitable for AgNi contact specifications .  
4) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing  
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.  
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT  
Unit: mm  
Outline Dimensions  
15.7  
0.3  
0.5  
0.6  
(Bottom view)  
2.54  
10.16  
1.2  
PCB Layout  
(Bottom view)  
Wiring Diagram  
(Bottom view)  
6x  
1
2.54  
10.16  
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be ±0.2mm; outline dimension 1mm  
and 5mm, tolerance should be ±0.3mm; outline dimension 5mm, tolerance should be ±0.4mm.  
2) The tolerance without indicating for PCB layout is always ±0.1mm.  
3) The width of the gridding is 2.54mm.  
46  
CHARACTERISTIC CURVES  
ENDURANCE CURVE  
MAXIMUM SWITCHING POWER  
100V  
500  
AC Resistive Load  
30VDC Resistive Load  
100V  
100  
50  
DC Resistive Load  
30V  
10V  
125VAC Resistive Load  
10  
10mV  
1
1
10A  
0
2
3
4
5
10uA  
100mA  
1A  
6
7
Switching Current (A)  
Test conditions:  
NO:AgNi, Resistive load, 85, 1s on 9s off.  
Contact Current  
Notice  
1) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage.  
2) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached  
the rated voltage.  
3) The relay may be damaged because of falling or when shocking conditions exceed the requirement.  
4) Plastic sealed type is recommended for an environment with noxious gas such as H2S, SO2 and NO2,ect., and/or when load current is low,  
and/or the PCB boards need to be washed after relays are soldered. For other using conditions flux proofed type could be adopted.  
5) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.  
6) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 40oC after welding, then clean it and deal with coating, remarkably  
the temperature of solvents should also be controlled below 40oC.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like  
gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment.  
7) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay".  
8) Please contact us for more details if you have different conditions of application.  
Disclaimer  
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to  
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s  
responsibility to determine which product should be used only.  
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.  
47  

相关型号:

HFD16/18-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/2.4-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/24-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/3-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/4.5-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/5-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/6-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD16/9-ZFH-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD17

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD17/12-ZF-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD17/18-ZF-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD17/2.4-ZF-3N

SUBMINIATURE SIGNAL RELAY
HONGFA