HFD16/12-ZFH-3N [HONGFA]
SUBMINIATURE SIGNAL RELAY;型号: | HFD16/12-ZFH-3N |
厂家: | HONGFA TECHNOLOGY |
描述: | SUBMINIATURE SIGNAL RELAY |
文件: | 总3页 (文件大小:469K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SUBMINIATURE SIGNAL RELAY
HFD16
Features
8A switching capability
●
●
●
●
●
UL insulation system: Class F available
Plastic sealed and flux proofed types available
Standard PCB layout
File No.: E133481
Product in accordance to IEC 60335-1 available
File No.: R50075326
RoHS compliant
COIL
CONTACT DATA
Contact arrangement
1C
Coil power
H type: 200mW;
100m max.
0.1A 30mVDC,
and AgSnO2:1A 30mVDC)
(AgNi gold-plated specifications:
Contact resistance1)
Contact material
AgNi non gold-plated specifications
COIL DATA
at 23
AgNi, AgSnO2
Contact rating
(Res. load)
3A 30VDC
1A 125VAC
Pick-up Drop-out
Coil Resistance
x (1 10%)
Max.
Voltage2)
VDC
Nominal
Voltage
VDC
Voltage Voltage
VDC1)
max.
VDC1)
min.
Max. switching voltage
Max. switching current
250VAC / 220VDC
8A(30VDC)
H
2.4
3
≤1.80 ≥0.24
≤2.25 ≥0.3
≤3.38 ≥0.45
3.12
3.90
5.85
6.50
6.63
11.7
15.6
23.4
31.2
28.8
45.0
101.3
120
750VA / 90W
Max. switching power
Min. applicable load
5V 1mA(Suitable for AgNi gold-plated specifications)
4.5
5
1 x 107OPS
Mechanical endurance
Electrical endurance
1x105OPS(NO:AgNi,85 ,1son9soff,3A30VDC)
1x104OPS(NO:AgNi,85 ,1son 9s off,5A125VAC)
≤3.75
≤4.5
≥0.5
≥0.6
≥0.9
≥1.2
≥1.8
≥2.4
6
180
Notes: 1) The data shown above are initial values.
2)Min. applicable load is reference value. Please perform the
confirmation test with the actual load before production since
reference value may change according to switching frequencies,
environmental conditions and expected contact resistance and
reliability.
9
≤6.75
≤9.00
≤13.5
≤18.0
400
12
18
24
700
1620
2800
CHARACTERISTICS
Insulation resistance
1000M (at 500VDC)
1100VAC 1min
750VAC 1min
Notes: 1) The data shown above are initial values.
2) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
between coil & contacts
between open contacts
Dielectric
strength
SAFETY APPROVAL RATINGS
Operate time (at rated voltage.)
Release time (at rated voltage.)
5ms max.
5ms max.
5A 125VAC
Functional
Shock resistance
1A 125VAC,85oC
98m/s2
980m/s2
AgNi
3A 30VDC,85oC
Destructive
UL/CUL
1A 125VAC ,85oC
3A 30VDC,85oC
TV-1 125VAC
Functional
10Hz to 55Hz 1.5mm DA
10Hz to 55Hz 3.3mm DA
Vibration resistance
AgSnO2
Destructive
Surge withstand voltage
1000V(FCC part 68)
1500V(Telecordia)
5% to 85% RH
-40 to 85
between open contacts(10/160 µ s)
between coil & contacts(2/10 µ s)
1A 250VAC
1A 125VAC, 85oC
3A 30VAC, 85oC
3A 250VAC
1A 250VAC,85oC
3A 30VAC, 85oC
1(1) 250VAC
AgNi
Humidity
Ambient temperature
Termination
TÜV
PCB (DIP)
Approx. 4g
AgSnO2
Unit weight
Plastic sealed,
Flux proofed
Construction
3A 250VAC
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
Notes: 1) The data shown above are initial values.
2) UL insulation system: Class F.
HONGFA RELAY
2020 Rev. 1.00
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED
45
ORDERING INFORMATION
24
HFD16/
-Z F H -3 N (XXX)
Type
Coil voltage
2.4,3, 4.5, 5, 6, 9, 12, 18, 24 VDC
Contact arrangement Z:1 Form C
Construction
Coil power
F: Flux proofed
Nil: Plastic sealed
H: High sensitive (200mW)
Contact material 3: AgNi
T: AgSnO2
Nil: gold plated3)
N: No gold plated
Contact plating
Special code1)
XXX: Customer special requirement
Nil: Standard
Notes: 1) The customer special requirement express as special code after evaluating by Hongfa.
2) The standard size of this pruduct tube package is 409mm, Any special requirement needed, please contact us for more details.
3) Only suitable for AgNi contact specifications .
4) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
15.7
0.3
0.5
0.6
(Bottom view)
2.54
10.16
1.2
PCB Layout
(Bottom view)
Wiring Diagram
(Bottom view)
6x
1
2.54
10.16
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.54mm.
46
CHARACTERISTIC CURVES
ENDURANCE CURVE
MAXIMUM SWITCHING POWER
100V
500
AC Resistive Load
30VDC Resistive Load
100V
100
50
DC Resistive Load
30V
10V
125VAC Resistive Load
10
10mV
1
1
10A
0
2
3
4
5
10uA
100mA
1A
6
7
Switching Current (A)
Test conditions:
NO:AgNi, Resistive load, 85℃, 1s on 9s off.
Contact Current
Notice
1) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage.
2) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached
the rated voltage.
3) The relay may be damaged because of falling or when shocking conditions exceed the requirement.
4) Plastic sealed type is recommended for an environment with noxious gas such as H2S, SO2 and NO2,ect., and/or when load current is low,
and/or the PCB boards need to be washed after relays are soldered. For other using conditions flux proofed type could be adopted.
5) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.
6) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 40oC after welding, then clean it and deal with coating, remarkably
the temperature of solvents should also be controlled below 40oC.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like
gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment.
7) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay".
8) Please contact us for more details if you have different conditions of application.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
47
相关型号:
©2020 ICPDF网 联系我们和版权申明