HFD17/5-ZF-3N [HONGFA]

SUBMINIATURE SIGNAL RELAY;
HFD17/5-ZF-3N
型号: HFD17/5-ZF-3N
厂家: HONGFA TECHNOLOGY    HONGFA TECHNOLOGY
描述:

SUBMINIATURE SIGNAL RELAY

文件: 总3页 (文件大小:609K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SUBMINIATURE SIGNAL RELAY  
HFD17  
Features  
8A switching capability  
UL insulation system: Class F available  
Plastic sealed and flux proofed types available  
Standard PCB layout  
File No.: E133481  
Product in accordance to IEC 60335-1 available  
File No.:R50431434  
RoHS compliant  
COIL  
CONTACT DATA  
Contact arrangement  
1C  
Coil power  
200mW;  
100m max.  
(AgNi gold-plated specifications:  
0.1A 6VDC, AgNi non gold-plated specifications  
and AgSnO2:1A 6VDC)  
Contact resistance1)  
Contact material  
COIL DATA  
AgNi, AgSnO2  
at 23  
Contact rating  
(Res. load)  
3A 30VDC  
3A 250VAC  
Pick-up Drop-out  
Coil Resistance  
x (1 10%)  
Max.  
Voltage2)  
VDC  
Nominal  
Voltage  
VDC  
Voltage Voltage  
VDC1)  
max.  
VDC1)  
min.  
Max. switching voltage  
Max. switching current  
Max. switching power  
Min. applicable load  
250VAC / 220VDC  
8A  
Standard  
1.80  
2.25  
3.38  
3.75  
4.5  
2.4  
3
0.24  
0.3  
0.45  
0.5  
0.6  
0.9  
1.2  
1.8  
2.4  
3.12  
3.90  
5.85  
6.50  
6.63  
11.7  
15.6  
23.4  
31.2  
28.8  
45.0  
101.3  
120  
750VA / 90W  
5V 1mA(Suitable for AgNi gold-plated specifications)  
1 x 107OPS  
1x105OPS(AgNi85C1son9soffNO.  
4.5  
5
Mechanical endurance  
o
Electrical endurance  
HFD17:3A 125VAC HFD17-1:1A 125VAC)  
6
180  
Notes: 1) The data shown above are initial values.  
2)Min. applicable load is reference value. Please perform the  
confirmation test with the actual load before production since  
reference value may change according to switching frequencies,  
environmental conditions and expected contact resistance and  
reliability.  
6.75  
9.00  
13.5  
18.0  
9
400  
12  
18  
24  
700  
1620  
2800  
CHARACTERISTICS  
Insulation resistance  
1000M (at 500VDC)  
750VAC 1min  
Notes: 1) The data shown above are initial values.  
2)Maximum voltage refers to the maximum voltage which relay  
coil could endure in a short period of time.  
between open contacts  
between coil & contacts  
Dielectric  
strength  
1500VAC 1min  
SAFETY APPROVAL RATINGS  
Surge withstand voltage  
between open contacts(10/160 µ s)  
between coil & contacts(2/10 µ s)  
1500V(FCC part 68)  
2000V(Telecordia)  
HFD17-1  
HFD17  
3A 125VAC,85oC  
3A 250VAC,Room temp  
3A 30VDC,85oC  
1A 125VAC,85oC  
1A 250VAC,Room temp  
1A 30VDC,85oC  
Operate time (at rated voltage.)  
Release time (at rated voltage.)  
Ambient temperature  
Humidity  
5ms max.  
5ms max.  
AgNi  
UL/CUL  
3A 250VAC,85oC  
3A 30VDC,85oC  
1A 250VAC,85oC  
1A 30VDC,85oC  
-40 to 85  
5% to 85% RH  
147m/s2  
AgSnO2  
TV-1 125VAC,Room temp  
Functional  
Shock resistance  
3A 125VAC,85oC  
3A 250VAC,Room temp  
3A 30VDC,85oC  
1A 250VAC,85oC  
980m/s2  
Destructive  
1A 250VAC,Room temp  
1A 30VDC,85oC  
AgNi  
Functional  
10Hz to 55Hz 2.5mm DA  
3A 250VAC,85oC  
Vibration resistance  
Destructive  
TÜV  
1A 250VAC,85oC  
10Hz to 55Hz 5mm DA  
DIP  
3A 30VDC,85oC  
1A 30VDC,85oC  
AgSnO2  
Termination  
Unit weight  
Construction  
1(1) 250VAC,Room temp 1(1) 250VAC,Room temp  
Approx. 4g  
Plastic sealed  
Flux proofed  
Notes: 1)Only typical loads are listed above. Other load specifications  
can be available upon request.  
Notes: 1) The data shown above are initial values.  
2) UL insulation system: Class F.  
HONGFA RELAY  
2020 Rev. 1.00  
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED  
48  
ORDERING INFORMATION  
24  
HFD17/  
HFD17:3A contact rating  
-Z F -3  
N (XXX)  
Type  
HFD17-1:1A contact rating  
Coil voltage  
2.4,3, 4.5, 5, 6, 9, 12, 18, 24 VDC  
Contact arrangement Z:1 Form C  
Construction  
F: Flux proofed  
3: AgNi  
Nil: Plastic sealed  
T: AgSnO2  
Contact material  
N: No gold plated  
Nil:Gold plated(Only for AgNi type)  
Contact plating  
Special code1)  
XXX: Customer special requirement  
Notes: 1) The customer special requirement express as special code after evaluating by Hongfa.  
2) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing  
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.  
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT  
Unit: mm  
Outline Dimensions  
15.7  
0.3  
0.5  
0.6  
1.2  
10.16  
2.54  
(Bottom view)  
Wiring Diagram  
PCB Layout  
(Bottom view)  
(Bottom view)  
5x  
1
2.54  
10.16  
Remark: 1) In case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be ±0.2mm; outline dimension 1mm  
and 5mm, tolerance should be ±0.3mm; outline dimension 5mm, tolerance should be ±0.4mm.  
2) The tolerance without indicating for PCB layout is always ±0.1mm.  
3) The width of the gridding is 2.5mm.  
49  
CHARACTERISTIC CURVES  
HFD17  
ENDURANCE CURVE  
30VDC Resistive Load  
MAXIMUM SWITCHING POWER  
1000V  
100V  
500  
AC Resistive Load  
100  
50  
DC Resistive Load  
30V  
10V  
125VAC Resistive Load  
10  
10mA  
1
7
10A  
0
1
2
3
4
5
6
1A  
10uA  
100mA  
Contact Current  
Contact Current  
Test conditions:  
AgNi, NO contact ,Resistive load, 85  
.
HFD17-1  
MAXIMUM SWITCHING POWER  
ENDURANCE CURVE  
1000V  
100V  
500  
AC 阻性负载  
30VDC 阻性负载  
100  
50  
DC 阻性负载  
30V  
10V  
125VAC 阻性负载  
10  
10mA  
1
10uA  
10A  
100mA  
0
3
5
1A  
1
2
4
6
7
Contact Current  
Contact Current  
Test conditions:  
AgNi, NO contact ,Resistive load, 85  
.
Notice  
1) To avoid using relays under strong magnetic field which will change the parameters of relays such as pick-up voltage and drop-out voltage.  
2) Energizing coil with rated voltage is basic for normal operation of a relay, please make sure the energized voltage to relay coil have reached  
the rated voltage.  
3) The relay may be damaged because of falling or when shocking conditions exceed the requirement.  
4) Plastic sealed type is recommended for an environment with noxious gas such as H2S, SO2 and NO2,ect., and/or when load current is low,  
and/or the PCB boards need to be washed after relays are soldered. For other using conditions flux proofed type could be adopted.  
5) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays on PCB.  
6) Regarding the plastic sealed relay, we should leave it cooling naturally untill below 40oC after welding, then clean it and deal with coating, remarkably  
the temperature of solvents should also be controlled below 40oC.Please avoid cleaning the relay by ultrasonic, avoid using the solvents like  
gasoline, Freon, and so on, which would affect the configuration of relay or influence the environment.  
7) About preferable condition of operation, storage and transportation, please refer to "Explanation to terminology and guidetines of relay".  
8) Please contact us for more details if you have different conditions of application.  
Disclaimer  
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to  
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s  
responsibility to determine which product should be used only.  
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.  
50  

相关型号:

HFD17/6-ZF-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD17/9-ZF-3N

SUBMINIATURE SIGNAL RELAY
HONGFA

HFD1N60

600V N-Channel MOSFET
SEMIHOW

HFD1N60S

600V N-Channel MOSFET
SEMIHOW

HFD1N65

650V N-Channel MOSFET
SEMIHOW

HFD1N65S

650V N-Channel MOSFET
SEMIHOW

HFD1N70

700V N-Channel MOSFET
SEMIHOW

HFD1N80

800V N-Channel MOSFET
SEMIHOW

HFD2

SUBMINIATURE DIP RELAY
ETC

HFD2/003-M-L1

Power/Signal Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 3A (Contact), 220VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
HONGFA

HFD2/003-M-L1-A

SUBMINIATURE DIP RELAY
HONGFA

HFD2/003-M-L1-D

SUBMINIATURE DIP RELAY
HONGFA