N7800A-U1R [HP]

Calibration and Adjustment Software for Agilent RF/W Instruments;
N7800A-U1R
型号: N7800A-U1R
厂家: HEWLETT-PACKARD    HEWLETT-PACKARD
描述:

Calibration and Adjustment Software for Agilent RF/W Instruments

文件: 总9页 (文件大小:379K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
[ Obsolete product ]  
Agilent has a new nam e  
KeysightTechnologies.  
Keysight Technologies Inc. is the world's leading electronic m easurem ent  
com pany, transform ing today's m easurem ent experience through innovations in  
wireless, m odular, and software solutions. W ith its HP and Agilent legacy,  
Keysight delivers solutions in wireless com m unications, aerospace and defense  
and sem iconductor m arkets with world-class platform s, software and  
consistent m easurem ent science.  
Alldatasheet.com  
Agilent N7800A  
Calibration and Adjustment  
Software for Agilent  
RF/µW Instruments  
Agilent customers choosing  
to perform their own periodic  
maintenance (performance  
verification and adjustments)  
can now use the same  
automated software used  
in Agilent Service Centers.  
Agilent strives to provide the  
best service available for a  
broad range of instruments, but  
you may be a customer who  
balances cost, quality, and cycle  
time requirements by performing  
your own calibrations whenever  
possible. You may have the  
necessary equipment, facility,  
manpower, and skill, but for  
complex RF/μW instruments, you  
could benefit greatly from having  
robust automated routines to  
facilitate the calibration task.  
The current families of Agilent RF/µW  
products are tested in Agilent Service  
Centers using a robust common soft-  
ware environment. We are offering  
licenses to customers who would  
like to use the same software. These  
licenses guarantee you have access  
to the most current versions of test  
software, while also protecting  
Agilent intellectual property from  
inappropriate use.  
Maximize your cal lab’s effectiveness,  
while minimizing turnaround time  
and cost.  
Gain confidence in calibrations  
and adjustments: take advantage  
of Agilent’s experience and  
expertise in calibration and  
adjustment software.  
With Agilent calibration software,  
you eliminate the time and expense  
involved in developing software  
yourself and you gain the confidence  
of knowing that your instruments are  
calibrated in accordance with the  
manufacturer’s recommended proce-  
dures. The software is designed with  
the flexibility you need to increase  
your company’s productivity and  
improve quality. As new instruments  
and/or options are released, you will  
save time by simply downloading the  
latest revision of software from the  
web. See page 7 for a full list of soft-  
ware features.  
• Measurement uncertainty analysis  
based on international standards1  
• Broad set of lab standards supported,  
all guaranteed to meet uncertainty  
requirements  
• ISO/IEC 17025 and ANSI/NCSL  
Z540.3 compliance  
• Automatic adjustments where  
applicable  
• Flexible test executive, data export,  
and system management included  
• Free web download of latest versions  
covering latest models and options  
• Network installation capability, with  
centralized data base  
This licensing applies to products in  
the following instrument families:  
PSA  
CSA  
PSG  
NFA  
ESA  
EMI  
ESG  
PNA  
VSA  
X-series  
MXG  
P-Series  
E8663B N4010A E6601A  
U200x 896xx  
Upconverters  
N9039A  
Downconverters  
Records indicate that over 10% of products appearing otherwise “healthy”  
actually fail some datapoint during testing, requiring adjustment. Even if  
they do not need hardware replacement or repair, such adjustment would  
require a round trip to a service provider if the adjustment tools are not  
available to a self-maintainer. Likewise, even when hardware can be  
repaired in the field, it often requires post-repair adjustment to ensure  
the instrument is performing within specifications.  
For a complete list of instrument  
model numbers, please refer to the  
table in page 6. As other families of  
instruments become supported with  
compatible PC-based calibration and  
adjustment software, they will be  
added to the licensing program. See  
page 6 for minimum PC requirements.  
Yes  
No  
No  
Run  
Run  
Diagnose &  
order parts  
Pass?  
Yes  
Pass?  
performance tests  
adjustments  
Install  
new parts  
Done  
Fig. 2 Calibration, Adjustment, and Repair process  
1.  
ISO Guide to Expression of Measurement Uncertainty, 1995.  
2
Save time and expense by  
automatically adjusting products  
that fail specifications.  
saves your metrology staff many  
weeks of complex calculations and  
analysis. You can generate the report  
format of your choice, to comply with  
the requirements of the standard(s)  
you must meet. Test results can be  
laboratory must make use of these  
Universal 90-day licenses if/when  
you calibrate outside equipment for  
commercial purposes. As the user,  
you can choose whether to provide  
a commercial calibration or a  
The days of screwdriver “tweaks” are  
long gone. Many of the performance  
advantages offered by Agilent products exported if you wish to maintain  
Z540/17025 calibration by choosing  
the corresponding 90-day license.  
are due to the ability to “fine tune”  
the hardware under microprocessor  
control. Amplifier gains, filter corners,  
DC offsets, and other functions can be  
adjusted according to measurement  
environment and component aging.  
These adjustments require complex  
iterative external measurements and  
calculations to characterize the instru-  
ment and then make the appropriate  
adjustments. Intimate knowledge of  
the architecture and detailed circuitry  
are required, so such adjustment ca-  
pability is available only in the Agilent  
calibration and adjustment software.  
Service Center records indicate that  
roughly 10% of the products calibrated  
initially fail some specification, but can  
be brought into compliance simply  
through automatic adjustment,  
eliminating the need for any hardware  
“repair”. From your perspective, that  
means saving a round-trip to an  
calibration records elsewhere.  
Product number Description  
You only need to buy one  
license for each calibration  
station that is to be operated  
using our software.  
N7800A-U1S  
TME Non-commercial  
seat license new  
install  
N7800A-U1R  
TME Non-commercial  
seat license,  
A licensed station can test all  
covered instrument models in any  
quantity for one year, and can test  
any new models/options released  
during the license period.  
renewal,  
(requires existing  
install)  
N7800A-U9C  
N7800A-U9Z  
N7800A-UPZ  
Universal 90-day  
license, individual  
instrument, Agilent  
Commercial  
Such a “seat license” may not  
be used to provide commercial  
calibration services for Agilent  
instruments.  
Calibration  
Universal 90-day  
license, individual  
instrument Agilent  
ANSI Z540 and  
ISO 17025 calibration  
Universal perpetual  
license, individual  
instrument, Agilent  
ANSI Z540 and  
ISO 17025 calibration  
You may use this seat license as a  
self-maintainer calibrating equipment  
you own, or equipment that is an  
integral part of a government program  
in which you are participating. This  
includes contractors who are operating  
calibration laboratories in support of  
government or military organizations.  
However, you may not use this seat  
license to provide general commercial  
calibration service.  
Agilent facility for adjustment.  
Automatically generate and  
report results of measurement  
uncertainty analyses.  
If your instrument volume does  
not justify a seat license, or your  
operational model would be better  
addressed by long-term individual in-  
strument licenses, we offer perpetual  
licenses for individual instruments.  
They provide full ANSI Z540 and ISO  
17025 analysis and reporting, and can  
be used with any instrument model  
covered by our Calibration Software.  
You are entitled to use our software  
tools for the lifetime of the product,  
and to any new revisions of software  
that might be issued. The license can  
be installed on as many systems, in  
as many places as you wish, so there  
are no geographic or time restrictions.  
The only limitation is that the license  
is valid only for the specific instrument  
serial number used to activate the  
license.  
While the gains Agilent software offers  
in shorter turnaround times and lower  
costs are important, Agilent has taken  
even greater steps in ensuring that  
calibration quality meets the highest  
possible standards. The software  
generates a measurement uncertainty  
analysis for each test point in any  
calibration you perform. That analysis  
is based upon the strictest possible  
interpretation of the regulatory  
The seat license must be renewed  
annually to maintain your access to  
the latest software revisions.  
For calibration labs providing  
commercial calibration services,  
we offer licenses to enable the  
calibration and/or adjustment  
of any covered instrument for a  
period of 90 days.  
standards, and is guaranteed to  
meet or exceed the requirements  
laid out by ISO 17025 or ANSI Z540.  
The engineering derivation of each  
uncertainty analysis often encompasses  
20 to 30 pages of complex equations, so  
having them embedded in the software  
When activated, these licenses are  
linked to a specific serial number and  
provide adequate time for testing,  
adjusting, repairing, and re-testing of  
that specific instrument. Even if you  
are primarily a self-maintainer, your  
3
All licenses include access to both  
performance verification tests and to  
automatic adjustments (if required to  
make the instrument pass specification).  
All licenses enable you to create full  
test result reports that can be  
Software may be downloaded, or you  
can check for the latest software  
revisions online.  
New software packages are released  
continually. For the most current list  
of software CDs, go to:  
agilent.com/find/calibrationsoftware  
Visiting our web site at www.agilent.  
com/find/calibrationsoftware is an  
excellent way to examine the thorough  
“Help” text included. Many details, such  
as system configuration, required test  
You may order the CD-ROM set  
exported to other systems. All  
containing the calibration software  
for the corresponding product family.  
Each software CD-ROM set includes  
test and adjustments for all products  
and options within that product family.  
For your convenience, every CD-ROM  
set includes a copy of the Agilent Test  
Management Environment (TME) test  
executive. The test executive need only  
be loaded once (whether downloaded  
or loaded from CD). After that, it is  
necessary only to load the product  
family-specific application software.  
self-maintainer seat licenses and the  
U9Z 90-day licenses enable you to re-  
port all uncertainty calculations within equipment (and alternatives), and test  
the final tabular report and graphs.  
descriptions, are included in the help  
text.  
Most software and licensing  
transactions with Agilent can  
be made quickly, online, at any  
time. Licenses are activated  
through a simple interaction  
with an Agilent web site.  
See page 7 for a collection of important  
web links pertaining to Cal SW Licensing.  
In addition, the calibration and  
adjustment application for each  
product family can be purchased on  
a CD (for a nominal charge) under  
the following product numbers,  
When a license is purchased, you  
receive a uniquely numbered Certificate should you be unable or unwilling  
Nothing has been done to disable  
older versions of Agilent test software.  
of Entitlement that you must then  
activate (“redeem”) online. You  
may go to the Agilent web site at  
agilent.com/find/softwarelicense  
at any time. Using your order number  
and your certificate number, you  
activate a license by:  
1) entering the MAC address of the  
test station PC to be licensed, in  
the case of “seat” licenses, or  
2) entering the model and serial  
number of an instrument to be  
licensed, in the case of individual  
perpetual or 90-day licenses.  
to download it free from the web:  
If you are using older versions of our  
test software (without uncertainty  
analysis reporting), you may continue  
to use that software to calibrate the  
corresponding products. However,  
please note that the older versions  
cannot reside on the same PC as the  
newer, licensed version. Attempting to  
have them on the same PC will result  
in file corruption that is difficult to  
correct. In addition, the older versions  
will not be updated for new products  
and options.  
Product  
number  
Application  
N7805A E6601A Wireless comms  
test set  
N7810A PSA Cal and adjust  
N7811A ESA Cal and adjust  
N7812A VSA (E4406A) Cal and  
adjust  
N7813A CSA Cal and adjust  
N7814A X-Series Cal and adjust  
N7815A 896xx Cal and adjust  
N7817A EMI Cal and adjust  
N7820A PSG Cal and adjust  
N7821A ESG-C (E4428C, E4438C)  
Cal and adjust  
Shortly afterward, you will receive an  
email with the electronic license file(s)  
attached. Using the instructions sup-  
plied, you import those licenses into  
your TME system, and you are then  
ready to calibrate.  
N7822A MXG Cal and adjust  
N7823A E8663B Cal and adjust  
N7824A ESG-B Cal and adjust  
N7830A NFA Cal and adjust  
N7831A N4010A Cal and adjust  
N7832A P-Series Power meters cal  
N7833A N8300A Wireless network  
test set  
N7840A PNA Cal  
N7845A Upconverter synthetic  
Instruments cal and adjust  
N7846A Downconverter synthetic  
instrument cal  
N7851A U200x Power sensor cal  
4
Automated test times are far less  
than the manual equivalent.  
ANSI Z540 and ISO 17025 uncer-  
tainty analyses are guaranteed  
to meet all requirements.  
Combine the advantages you  
have as a self-maintainer with  
the experience that Agilent  
has in high-performance  
metrology to achieve the  
optimum level of internal  
process control and external  
accreditation.  
They are also guaranteed to return  
more consistent, repeatable results  
across all test conditions.  
If you are trying to achieve certification,  
you can rely on the Agilent uncertainty  
analyses to meet the strictest interpre-  
tations of Z540/17025 requirements.  
The exact same analyses are used in  
our certified Service Centers. All seat  
licenses include Z540/17025 reporting  
capability. For the 90-day licenses, you  
can choose whether to pay a modest  
price premium for Z540/17025 over  
the commercial calibration license  
price. Agilent TME software already  
meets the requirements of Z540.3.  
If you normally require a Z540 or  
17025 calibration before you can put  
equipment into program use, you can  
now perform such a calibration on  
your own, rather than arranging for a  
special calibration from Agilent or other  
service providers. Your “incoming  
inspection” can be run as a Z540  
(or 17025) calibration.  
Your “cost of calibration” will be  
predictable from year-to-year,  
because all technical support, software  
updates, new products and options,  
and revision control are included in the  
price of a single renewable license.  
Agilent calibration routines are  
available at the time of product/  
option introduction.  
If you purchase a newly-released  
product or option, you can immediately  
verify its performance, rather than  
waiting 1-2 years for other software  
alternatives (i.e. creating your own  
test software or purchasing software  
from a third party).  
A knowingly maladjusted  
instrument was chosen to gather  
this data, to demonstrate how  
measurement uncertainty can affect  
the pass/fail conclusion associated  
with measurement data that never  
exceeds the actual specification  
limit. “Indeterminate,” in this  
case, should be taken to mean  
Adjustment Recommended,”  
Fig. 3 Reports show Measured Value, Specification, and Uncertainty  
5
Minimum PC System  
Requirements  
Instruments Covered  
For the latest list of instruments covered please see:  
agilent.com/find/calibrationsoftware  
● PC Hardware  
• 450 MHz Pentium II  
(600 MHz or faster recommended)  
• 128 MB RAM  
Product family  
PSA spectrum analyzers  
ESA spectrum analyzers  
Models  
E4440A, E4443A, E4445A, E4446A, E4447A, E4448A  
E4401B, E4402B, E4403B, E4404B, E4405B,  
E4407B, E4408B, E4411B, E7401A, E7402A,  
E7403A, E7404A, E7405A  
(256 MB or more recommended)  
• 200 MB available hard drive  
NOTE: Data storage will average  
approximately 200 MB of disk  
space per 100 full instrument  
calibrations. Test data is saved for  
every test that is run within TME  
therefore overall data storage  
needs will vary depending on the  
number of instruments calibrated.  
• Minimum 800 x 600 display with  
256 colors  
VSA vector signal analyzer E4406A  
VSA vector signal analyzer 896xxA  
CSA spectrum analyzer  
EXA signal analyzer  
MXA signal analyzer  
EMI receiver  
N1996A  
N9010A  
N9020A  
N9039A  
PSG signal generators  
E8241A, E8244A, E8247C, E8251A, E8254A, E8257C,  
E8257D, E8267C, E8267D  
ESG signal generators  
E4428C, E4438C, E4400B, E4420B, E4421B, E4422B,  
E4423B, E4424B, E4425B, E4426B, E4430B, E4431B,  
E4432B, E4433B, E4434B, E4435B, E4436B, E4437B  
N5181A, N5182A  
• GPIB card (One of the following  
cards must be installed prior to  
installing this application):  
• Agilent 82350A*  
• NI GPIB/TNT**  
• NI PCI-GPIB**  
MXG signal generators  
E8663B signal generator  
E8663B  
NFA noise figure analyzers N8972A, N8973A, N8974A, N8975A  
Wireless connectivity  
test set  
N4010A  
● Operating system supported:  
• Windows 2000 (SP3 or higher)  
• XP Professional (SP1 or SP2)  
PNA network analyzers  
E8356A, E8357A, E8358A, E8361A, E8362A, E8362B,  
E8363A, E8363B, E8364A, E8364B, E8801A, E8802A,  
E8803A, N3381A, N2282A, N3383A, N5230A  
N8211A, N8212A  
● Additional software:  
• I/O Libraries  
Upconverter synthetic  
instrument  
Agilent VISA* (Recommended  
version M.01.01.04 or later)  
or  
P-series power meters  
Wireless comms test set  
N1911A, N1912A, add N8262A  
E6601A  
U2000-series power sensors U200xA  
Wireless network test set N8300A  
NI VISA** (Recommended  
version 3.2 or later ***)  
Downconverter synthetic  
instrument  
N8201A  
• Web Browser  
Internet Explorer (IE) 5.5 or higher  
*
Agilent Visa & GPIB drivers can be  
downloaded from the Agilent Technologies  
website at: www.agilent.com  
** National Instruments Visa library can be  
downloaded from the website: www.ni.com  
***Version 3.2 of the National Instruments VISA  
will fix an issue found in the TME installation.  
If any version of NI VISA prior to 3.2 is  
installed on the target system, you may  
experience an error during installation of the  
Agilent IO library to be used with TME.  
The kernel error that occurs will not affect  
the performance of TME once the installation  
completes. To avoid the error, upgrade to  
Version 3.2 of the NI VISA before executing  
the TME installation.  
6
Licensed Software Features  
Important Web Links  
(externally accessible)  
Seat  
90-day  
Z540/  
17025  
90-day  
Commercial  
Individual  
License  
To download actual calibration software:  
calsw.tm.agilent.com/  
License or  
Individual  
Feature  
Perpetual Individual  
License  
To redeem license certificates:  
agilent.com/find/softwarelicense  
License  
Fully meets audit requirements  
X
X
X
(processes comply with ISO 17025)  
Fully traceable to national and interna-  
tional standards  
Agilent quality measurement methods  
Networked Installation  
Determination of malfunction  
Instrument adjustment if found out of  
tolerance  
For more information:  
X
X
X
• Program Overview  
• Recommended Lab Standards  
• Alternative Supported Lab Standards  
• Getting Started Guide and Tutorial  
• Free Sample Trial  
X
X
X
X
X
X
X
X
X
X
X
X
agilent.com/find/calibrationsoftware  
Full after calibration performance data  
Full “on receipt” performance data  
Calibration suitable for general use  
Increased measurement confidence  
from many more test points  
X
X
X
X
X
X
X
X
X
X
X
X
Complete instrument functionality tested  
Measurement uncertainties provided  
with the calibration data  
X
X
X
X
X
Full conformance to ANSI Z540 and  
IEC/ISO17025 requirements  
X
X
7
www.agilent.com  
For more information on Agilent  
Technologies’ products, applications or  
services, please contact your local Agilent  
office. The complete list is available at:  
www.agilent.com/find/contactus  
Agilent Email Updates  
Remove all doubt  
www.agilent.com/find/emailupdates  
Get the latest information on the products  
and applications you select.  
Our repair and calibration services  
will get your equipment back to you,  
performing like new, when promised.  
You will get full value out of your Agilent  
equipment throughout its lifetime. Your  
equipment will be serviced by Agilent-  
trained technicians using the latest  
factory calibration procedures, auto-  
mated repair diagnostics and genuine  
parts. You will always have the utmost  
confidence in your measurements.  
Agilent Direct  
Americas  
www.agilent.com/find/agilentdirect  
Quickly choose and use your test  
equipment solutions with confidence.  
Canada  
Latin America  
United States  
877 894 4414  
305 269 7500  
800 829 4444  
Asia Pacific  
Agilent  
Open  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
Thailand  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 112 929  
81 426 56 7832  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
1 800 226 008  
www.agilent.com/find/open  
Agilent offers a wide range of additional  
expert test and measurement services  
for your equipment, including initial  
start-up assistance onsite education  
and training, as well as design, system  
integration, and project management.  
Agilent Open simplifies the process of  
connecting and programming test systems  
to help engineers design, validate and  
manufacture electronic products. Agilent  
offers open connectivity for a broad range  
of system-ready instruments, open industry  
software, PC-standard I/O and global  
support, which are combined to more  
easily integrate test system development.  
For more information on repair and  
calibration services, go to  
Europe & Middle East  
www.agilent.com/find/removealldoubt  
Austria  
Belgium  
Denmark  
Finland  
France  
0820 87 44 11  
32 (0) 2 404 93 40  
45 70 13 15 15  
www.lxistandard.org  
LXI is the LAN-based successor to GPIB,  
providing faster, more efficient connec-  
tivity. Agilent is a founding member of the  
LXI consortium.  
358 (0) 10 855 2100  
0825 010 700*  
*0.125 € fixed network rates  
Germany  
01805 24 6333*  
*0.14€/minute  
Ireland  
Israel  
Italy  
Netherlands  
Spain  
1890 924 204  
972 3 9288 504/544  
39 02 92 60 8484  
31 (0) 20 547 2111  
34 (91) 631 3300  
0200-88 22 55  
Sweden  
Switzerland (French)  
Switzerland (German)  
United Kingdom  
Other European Countries:  
41 (21) 8113811 (Opt 2)  
0800 80 53 53 (Opt 1)  
44 (0) 118 9276201  
www.agilent.com/find/contactus  
Revised: October 24, 2007  
Product specifications and descriptions  
in this document subject to change  
without notice.  
© Agilent Technologies, Inc. 2007, 2008  
Printed in USA, July 29, 2008  
5989-6956EN  

相关型号:

N7800A-U1S

Calibration and Adjustment Software for Agilent RF/W Instruments
HP

N7800A-U9C

Calibration and Adjustment Software for Agilent RF/W Instruments
HP

N7800A-U9Z

Calibration and Adjustment Software for Agilent RF/W Instruments
HP

N7800A-UPZ

Calibration and Adjustment Software for Agilent RF/W Instruments
HP

N7803-1C

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7803-1CW

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7803-1PH

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7803-1PV

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7805-1C

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7805-1CW

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7805-1PH

1A Non-Isolated DC-DC Switching Regulator
MEANWELL

N7805-1PV

1A Non-Isolated DC-DC Switching Regulator
MEANWELL