GT11-1822PCF(70) [HRS]

Connector Accessory;
GT11-1822PCF(70)
型号: GT11-1822PCF(70)
厂家: HRS    HRS
描述:

Connector Accessory

PC 连接器 连接器支架
文件: 总16页 (文件大小:3368K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Coaxial cable connection of Antennas, Sensors, and CommunicationTrunk Lines  
GT11 Series  
— Connectors for shielded cables —  
Features  
A housing lance systems has been used to prevent binding between contacts.  
Lock-release latching system  
84  
GT11 Series  
For Double-Conductor shielded cable  
24.3  
F Connectors  
Outer terminals  
8
RoHS  
YES  
Item  
Material  
Color/Finish  
Part Number  
HRS No.  
Applicable Cable  
GT11-2S-5.2C(70) 761-0002-3-70  
GT11-2S-6.0C(70) 761-0028-7-70  
4.5 to 5.2mm  
5.8 to 6.2mm  
Outer terminal  
Insulator  
Brass  
PBT  
Tin plating  
Dark Gray  
Note :The suitable terminals might differ depending on the internal structure of the cable.  
1.95  
1.95  
InnerTerminals  
18  
22  
RoHS  
YES  
Part Number  
HRS No.  
Conductor Size (AWG)  
Material  
Finish  
Packaging  
reel  
GT11-1822SCF(70) 761-0004-9-70  
GT11-2428SCF(70) 761-0020-5-70  
#18 to 22  
#24 to 28  
Phosphor  
Bronze  
Tin plating 8,000 pcs  
/
*Sold by the reel.  
25.3  
M Connectors  
Outer terminals  
9.6  
RoHS  
YES  
Part Number  
HRS No.  
Applicable Cable  
Item  
Material  
Color/Finish  
GT11-2P-5.2C(70) 761-0001-0-70  
GT11-2P-6.0C(70) 761-0027-4-70  
4.5 to 5.2mm  
5.8 to 6.2mm  
Outer terminal  
Insulator  
Brass  
PBT  
Tin plating  
Dark Gray  
Note :The suitable terminals might differ depending on the internal structure of the cable.  
0.64  
InnerTerminals  
1
18  
22  
RoHS  
YES  
Part Number  
HRS No.  
Conductor Size (AWG) Material  
Finish  
Packaging  
8,000 pcs  
GT11-1822PCF(70) 761-0003-6-70  
GT11-2428PCF(70) 761-0019-6-70  
#18 to 22  
Brass  
Tin plating  
/reel  
#24 to 28  
85  
GT11 Series  
For Double-Conductor shielded cable  
B
Shown with inserted retainer  
F Connectors  
Housing  
30  
CAV No  
RoHS  
Part Number  
GT11-2S-HU  
HRS No.  
Material  
PBT  
Color  
YES  
761-0005-1  
Light Gray  
M Connectors  
Housing  
B
Shown with inserted retainer  
35.8  
RoHS  
YES  
Part Number  
GT11-2P-HU  
HRS No.  
Material  
PBT  
Color  
761-0006-4  
Light Gray  
Housing  
B
B
Shown with inserted retainer  
Fully mated connector assemblies  
RoHS  
YES  
Part Number  
HRS No.  
Material  
PBT  
Color  
GT11N-2PP-HU  
761-0008-0  
Light Gray  
86  
GT11 Series  
M Connectors  
B
Recommended Board Mounting Pattern  
Housing  
RoHS  
Part Number  
HRS No.  
Material  
Finish  
Color  
PBT  
Brass  
PBT  
----  
Light Gray  
----  
Dark Gray  
----  
Tin plating  
----  
Tin plating  
YES  
GT11-2P-DS(70) 761-0007-7-70  
Phosphor bronze  
B
B
Recommended  
Fully mated connector  
Housing (GangType)  
Panel Cut-out  
assemblies  
B
Recommended Board  
Mounting Pattern  
RoHS  
YES  
Part Number  
HRS No.  
Material  
Finish  
Color  
PBT  
Brass  
PBT  
----  
Light Gray  
----  
Dark Gray  
----  
Tin plating  
----  
Tin plating  
GT11X-2/2P-DS(70) 761-0022-0-70  
Phosphor bronze  
B
Recommended Board Mounting Pattern  
Housing (StraightType)  
B
Fully mated connector assemblies  
GT11-2S-HU  
GT11-2P-DSA(70)  
RoHS  
YES  
Part Number  
Material  
Finish  
Color  
HRS No.  
PBT  
Brass  
Phosphor bronze  
Phosphor bronze  
----  
Light Gray  
Tin plating  
Tin plating  
Tin plating  
----  
----  
----  
GT11-2P-DSA(70) 761-0038-0-70  
87  
GT11 Series  
Waterproof type For Double-Conductor shielded cable  
45.4  
F Connectors  
Housing  
32.5  
Part Number  
HRS No.  
Material  
PBT  
Color  
RoHS  
YES  
GT11W-2S-HU 761-0024-6  
Light Gray  
M Connectors  
Housing  
20.5  
44.2  
24.1  
B
Fully mated connector assemblies  
Part Number  
GT11W-2P-HU  
HRS No.  
Material  
PBT  
Color  
RoHS  
YES  
761-0023-3  
Light Gray  
Housing  
20.5  
46.7  
26.6  
B
Fully mated connector assemblies  
HRS No.  
-----------  
Color  
RoHS  
YES  
Part Number  
Material  
PBT  
Light Gray  
GT11WM-2P-HU  
(It is planning)  
88  
GT11 Series  
Retainer (Used with GT11W-2S-HU and GT11W-2P-HU)  
Part Number  
GT11W-6.0R  
HRS No.  
Material  
RoHS  
YES  
PBT  
761-0025-9  
Silicon rubber compound  
Note : Waterproofness will depend on the cable. Please contact a Hirose Electric  
sales representative for further information when using this product.  
Retainer (Used with GT11W-2S-HU and GT11W-2P-HU)  
(It is planning)  
Part Number  
GT11W-5.2R  
HRS No.  
-------------  
Material  
RoHS  
YES  
PBT  
Silicon rubber compound  
Note : Waterproofness will depend on the cable. Please contact a Hirose Electric  
sales representative for further information when using this product.  
Retainer Cover  
9.45  
22.45  
(It is planning)  
Part Number  
HRS No.  
Material  
RoHS  
YES  
PBT  
GT11WM-COVER(A),(B) -------------  
Note : for GT11WM-5.2R  
Silicon rubber compound  
89  
GT11 Series  
B
Termination sequence  
Insert the internal terminals into the Outer terminals.  
Strip the cable.  
The joined side of the crimp portion faces upward  
(for both male and female).  
Shield  
Jacket  
Cut the shield and expose the wire.  
Wire  
Crimp the Outer terminal.  
The shield must be visible.  
Cut back the shield above the jacket and wrap with  
conductive tape.  
conductive tape  
Jig used: Outside tube caulking jig.  
(Refer to Page 103 for detail.)  
Strip the wire and form it.  
Conductor  
Crimp the wire to the internal terminal.  
Mount the retainer to complete the task.  
less than 1mm  
Jig used: Automatic crimping machine.  
(Refer to Page 103 for detail.)  
Refer to Page 96 for information  
about the retainer mounting  
method.  
90  
GT11 Series  
B
Retainer Mounting Method  
a. Insert so that the terminal  
locking tab is inserted  
between the top surface of  
the terminal and the  
housing.  
b. Push in while changing  
the angle of the retainer  
until the front surface  
comes to a stop.  
c. Press the rear portion of  
the retainer and snap it  
into the locked position.  
d. If locking is not complete,  
press the rear portion of  
the retainer again while  
pulling it backward.  
* Check that all locations are locked.  
91  
GT11 Series  
B
TerminationTools  
User's manuals are available. Please ask your Hirose Electric account representative.  
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)  
The photograph shows just  
one example.The product is  
subject to change.  
Specifications  
Item  
Capacity  
Specification  
1.5tons  
Remarks  
Stroke  
30mm  
Number of strokes  
Weight  
200spm (50Hz)  
75kg  
200spm (60Hz)  
AC100V  
Motor  
0.2kW  
Crimping speed  
2000 to 4000 pcs/hour  
Part Number CM-105  
Note: See the table below for the applicator product number.  
Product No.  
Applicator Product No. (2 conductor) Applicator Product No. (8 conductor)  
GT11-1822SCF(70)  
GT11-1822PCF(70)  
GT11-2428SCF(70)  
GT11-2428PCF(70)  
Applicator 105-GT11-1822S-2  
Applicator 105-GT11-1822P-2  
Applicator 105-GT11-2428S-2  
Applicator 105-GT11-2428P-2  
Applicator 105-GT11-1822S  
Applicator 105-GT11-1822P  
Applicator 105-GT11-2428S  
Applicator 105-GT11-2428P  
OuterTerminal Crimping tool  
Please contact a sales representative for information about the outer terminal crimping tool.  
92  
GT11 Series  
For 8-Conductor shielded cable  
1.95  
1.95  
F Connectors  
InnerTerminal  
RoHS  
YES  
Part Number  
GT11-1822SCF(70) 761-0004-9-70  
GT11-2428SCF(70) 761-0020-5-70  
HRS No.  
Conductor Size (AWG)  
#18 to 22  
Material  
Phosphor bronze  
Phosphor bronze  
Finish  
Tin plating  
Tin plating  
#24 to 28  
13  
Insulator  
8.4  
2.8  
RoHS  
YES  
Part Number  
GT11-8DS-2.8C  
HRS No.  
761-0014-2  
Material  
PBT  
Outer terminals  
12.7  
9.15  
0.4  
RoHS  
YES  
Part Number  
GT11-8DS-5C(70) 761-0015-5-70  
HRS No.  
Material  
Brass  
Finish  
Tin plating  
93  
GT11 Series  
Shield Plate  
12.7  
4.5  
9
Part Number  
GT11-8DS-SB(70) 761-0016-8-70  
HRS No.  
Material  
Brass  
Finish  
Tin plating  
RoHS  
YES  
Housing  
15.8  
34  
RoHS  
Part Number  
GT11-8DS-HU  
HRS No.  
761-0017-0  
Material  
PBT  
YES  
Retainer (used with GT11-8DS-HU)  
4.4  
14.1  
2.7  
6
RoHS  
YES  
Part Number  
GT11-8DS-6R  
HRS No.  
761-0018-3  
Material  
PBT  
94  
GT11 Series  
1
0.64  
M Connectors  
InnerTerminals  
Part Number  
GT11-1822PCF(70) 761-0003-6-70  
GT11-2428PCF(70) 761-0019-6-70  
HRS No.  
Conductor Size (AWG)  
#18 to 22  
Material  
Brass  
Brass  
Finish  
Tin plating  
Tin plating  
RoHS  
YES  
* Sold by the reel (8,000 pcs/reel)  
#24 to 28  
18.4  
Insulator  
7.5  
8.4  
2.8  
RoHS  
YES  
Part Number  
GT11-8DP-2.8C  
HRS No.  
761-0009-2  
Material  
PBT  
Outer terminal  
14  
10.25  
0.4  
RoHS  
YES  
Part Number  
GT11-8DP-5C(70) 761-0010-1-70  
HRS No.  
Material  
Brass  
Finish  
Tin plating  
95  
GT11 Series  
24.65  
Shield Plate  
0.4  
6.5  
RoHS  
YES  
Part Number  
GT11-8DP-SB(70) 761-0011-4-70  
HRS No.  
Material  
Brass  
Finish  
Tin plating  
Housing  
39.6  
25  
RoHS  
Part Number  
GT11-8DP-HU  
HRS No.  
761-0012-7  
Material  
PBT  
YES  
Retainer (Only for GT11-8DS-HU)  
4.4  
15.35  
2.7  
RoHS  
YES  
Part Number  
GT11-8DP-6R  
HRS No.  
-------  
Material  
PBT  
6
(It is planning)  
96  
GT11 Series  
BoardType  
B
Recommended Board Mounting Pattern  
24.7  
16.8  
29.95  
22.25  
5
2.8  
8.4  
1.3  
14.3  
3
2.8  
1.3  
13.25  
B
Fully mated connector assemblies  
44  
GT11-8DS-2.8C  
GT11-8DP-2.8DS(70)  
Board  
RoHS  
YES  
Part Number  
HRS No.  
Item  
Housing  
Material  
PBT  
Finish  
OuterTerminal Phosphor bronze  
Insulator  
Terminal  
Tin plating  
Tin plating  
GT11-8DP-2.8DS(70) 761-0021-8-70  
PBT  
Brass  
97  
GT11 Series  
B
Termination sequence  
Strip the Jacket.  
Insert the inner terminals into the insulated case.  
Inshulated case  
Shield  
Jacket  
Cut the shield and expose  
Insert what was made in Step into the Outer  
the wire.  
terminal.  
Outer terminal  
Wire  
Cut back the shield above  
the jacket and wrap with  
conductive tape.  
Insert the caulking shield cover onto the Outer  
terminal.  
Shield cover  
Conductive tape  
Strip the wire.  
Insert what was made in Step into the housing.  
Housing  
Crimp the internal terminals.  
Insert the retainer.  
Internal terminal  
Retainer  
Completion  
98  
GT11 Series  
B
TerminationTools  
User's manuals are available. Please ask your Hirose Electric account representative.  
Automatic Crimping Machine (for 2-conductor and 8-conductor cable)  
Specifications  
The photograph shows just  
one example.The product is  
Item  
subject to change.  
Specification  
Remarks  
Capacity  
1.5Ton  
30mm  
Stroke  
Number of strokes  
Weight  
200spm (50Hz)  
240spm (60Hz)  
75kg  
Motor  
0.2kW  
AC100V  
Crimping speed  
2000 to 4000 pcs. per hour  
Product Number Applicator Product Number (2-conductor type) Applicator Product Number (8-conductor type)  
GT11-1822SCF(70) Applicator 105-GT11-1822S-2  
GT11-1822PCF(70) Applicator 105-GT11-1822P-2  
GT11-2428SCF(70) Applicator 105-GT11-2428S-2  
GT11-2428PCF(70) Applicator 105-GT11-2428P-2  
Applicator 105-GT11-1822S  
Applicator 105-GT11-1822P  
Applicator 105-GT11-2428S  
Applicator 105-GT11-2428P  
Part Number CM-105  
Outer terminal Caulking Jig (for 8-conductor cable)  
Hand Press  
Part Number GT11-8S/P-HP  
99  

相关型号:

GT11-1822SCF

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
HRS

GT11-1822SCF(70)

Connector Accessory
HRS

GT11-2/2P-HU

Rectangular Connector
HRS

GT11-2/2S-HU

Rectangular Connector
HRS

GT11-2428PCF

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
HRS

GT11-2428PCF(70)

Connector Accessory
HRS

GT11-2428SCF

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
HRS

GT11-2P-5.2C

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
HRS

GT11-2P-6.0C

Coaxial cable connection of Antennas, Sensors, and Communication Trunk Lines
HRS

GT11-2P-DS

Rectangular Connector
HRS

GT11-2P-DS(70)

Rectangular Connector
HRS

GT11-2P-DSA

Rectangular Connector
HRS