LF10WBJ-4S [HRS]
Circular Connector, 4 Contact(s), Zinc Alloy, Female, Crimp Terminal, Jack;型号: | LF10WBJ-4S |
厂家: | HRS |
描述: | Circular Connector, 4 Contact(s), Zinc Alloy, Female, Crimp Terminal, Jack 连接器 |
文件: | 总11页 (文件大小:341K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
NEW
Miniature Waterproof Shielded Connectors
LF Series
Mated dimensions
8.9 mm max. (3 pos.)
36.4
Receptacle
Plug
Short turn bayonet lock
Mating:
Insert the plug, and then turn the locking collar clockwise,
as indicated by the coupling direction marking.
■Features
1. Ease of shielded termination and connector
Plug
assembly
Coupling direction marking
Receptacle
Un-mating:
Locking collar
All components are self-aligning and do not require complex
assembly tooling. The shield of the cable is connected with the
metal housing of the connector using simple shielding clamp,
supplied with the connector.
Turn the locking collar counter-clockwise
than pull off the plug.
2. Water and dust protected
IP67 protection rating. Complete protection against dust
penetration and against water penetration when mated
assembly is submerged at the depth of 1.8 meter for 48 hours.
Coupling direction marking
Shielding Connection - Plug
Built-in shield
3. Bayonet lock
Short turn bayonet lock assures secure vibration resistant
mating of the connectors.
4. High current rating capacity
connection spring
Cable shielding connection clamp
Number of contacts
Current rating
Cable
3
5A max.
4
10A max.
2A max.
6, 12 and 20
10A max.
2A max.
11
5. RoHS compliant
All components and materials comply with the requirements of
the EU Directive 2002/95/EC.
■Applications
Sensors, robots, injection molding machines, NC, factory
automation equipment, surveying instruments, measuring
instruments, medical equipment, surveillance cameras and
base stations.
2008.5
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
■Product Specifications
125V AC, 175V DC (3 pos.)
125V AC, 125V DC (4 pos.)
30V AC, 42V DC (6 pos. , 12pos. , 20pos.)
125V AC, DC (11 pos. A to D)
30V AC, 42V DC (11 pos. 1 to 7)
5A max. (3 pos.)
10A max. (4 pos.)
2A max. (6 pos. , 12pos. , 20pos.)
10A(11 pos. A to D), 2A(11 pos. 1 to 7)
Voltage rating
Rating
Current rating
–
–
Operating temperature range
Storage temperature range
25ç to +85ç (Note 1)
25ç to +85ç (Note 2)
Item
Specification
Conditions
15 mø max. (3, 6, 12, 20 pos.)
15 mø max. (4 pos.)
15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.)
11.Contact resistance
1A DC
500V DC (3, 4 pos.)
12.Insulation resistance
13.Withstanding voltage
1000 Mø min.
100V DC (6, 12, 20 pos.)
500V DC (A to D), 100V DC (1 to 7)(11pos.)
1250V AC/one minute (3, 4 pos.)
300V AC/one minute (6, 12, 20 pos.)
1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.)
No flashover or insulation breakdown.
No electrical discontinuity for 10μs max.
No electrical discontinuity for 10μs max.
Frequency: 10 to 500Hz, single amplitude of 0.75mm,
14.Vibration
15.Shock
2
acceleration of 98 m/s for 3 hours in 3 axis.
2
Acceleration of 490m/s , 11ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis.
30 mø max.
10 mø max.
(3, 6, 12, 20 pos.)
(4 pos.)
16.Durability
1000 cycles
16.(Mating/un-mating)
10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.)
Temperature: -55ç ➝ Room temperature ➝ +125ç ➝ Room temperature
Time: 30 ➝ 10 to 15 ➝ 30 ➝ 10 to 15 (minutes) 5 cycles
17.Temperature cycle
Insulation resistance: 100 Mø min.
Insulation resistance: 110 Mø min. (When temperature high)
Insulation resistance: 100 Mø min. (Dray state)
96 hours at temperature of 40ç and humidity of 90% to 95%.
18.Humidity
Complete dust protection. No water penetration
19.Water / dust protection
When mated with corresponding connector.
when submerged for 48 hours at the depth of 1.8 meter.
Note 1: Includes temperature rise caused by the current flow.
Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature range
and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation.
■Materials / Finish
Components
Body / back shell
Insulator
Material
Zinc alloy
Finish / Color
Nickel plated
Black
Remarks
––––––––––
UL94V-0
––––––––––
––––––––––
PPS
Contacts
Copper alloy
Chloroprene rubber
Gold plated
Black
Gasket
■Ordering Information
Series name
: LF
1
2
Shell size
07
10
13
Waterproof
W : Waterproof type
B : Bayonet lock
P : Plug
3
4
5
-
-
LF 07 W B P 6 S
Lock Mechanism
Connector type
1
2
3
4
5
6
7
R : Receptacle
J : Jack
Number of contacts
Contact type
: 3, 4, 6, 11, 12, 20
P : Male contact
S : Female contact
6
7
2
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
■Plugs
B
(Shown one example)
Unit:mm
Part number
LF07WBP-3S
LF07WBP-3P
LF07WBP-6S
LF07WBP-6P
LF10WBP-4S
LF10WBP-4P
LF10WBP-12S
LF10WBP-12P
LF13WBP-20S
LF13WBP-20P
LF13WBP-11S
LF13WBP-11P
CL No.
Contact Number of contacts
ØA
B
ØC
5
Weight RoHS
136-0003-7
136-0004-0
136-0001-1
136-0002-4
136-0005-2
136-0006-5
136-0007-8
136-0008-0
136-0009-3
136-0010-2
136-0011-5
136-0012-8
Female
3
Male
12.3
35.3
11g
Female
6
Male
Female
4
Male
14.8
17.9
41.8
51.9
7.3
8.7
17g
29g
YES
Female
12
Male
Female
20
Male
Female
11
Male
■Receptacles
C
D
E
F(HEX)
(Shown one example)
Unit:mm
Part number
LF07WBR-3P
LF07WBR-3S
LF07WBR-6P
LF07WBR-6S
LF10WBR-4P
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF13WBR-20P
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
CL No.
Contact Number of contacts
ØA
ØB
13
C
D
E
F
Weight RoHS
136-1003-2
136-1004-5
136-1001-7
136-1002-0
136-1005-8
136-1006-0
136-1007-3
136-1008-6
136-1009-9
136-1010-8
136-1011-0
136-1012-3
Male
3
6
4
15.15
Female
10.3
7.65 1M9∞0.75
7.75 M11∞0.75
11
4g
Male
15.05
15.25
Female
Male
19.05
17.25
6g
Female
12.8
15.9
15.3
18.3
13
17
YES
5g
Male
12
Female
6g
9g
Male
20
10g
9g
Female
19.05 7.75
M14∞0.75
Male
11
10g
Female
Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.)
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
■Jacks
C
(Shown one example)
Unit:mm
Part number
LF07WBJ-3P
LF07WBJ-3S
LF07WBJ-6P
LF07WBJ-6S
LF10WBJ-4P
LF10WBJ-4S
LF10WBJ-12P
LF10WBJ-12S
LF13WBJ-20P
LF13WBJ-20S
LF13WBJ-11P
LF13WBJ-11S
CL No.
Contact Number of contacts
ØA
ØB
C
ØD
5.0
Weight RoHS
136-2003-8
136-2004-0
136-2001-2
136-2002-5
136-2005-3
136-2006-6
136-2007-9
136-2008-1
136-2009-4
136-2010-3
136-2011-6
136-2012-9
Male
3
Female
10.3
11.5
36.3
11g
Male
6
Female
Male
4
Female
12.8
15.9
13.8
16.9
42.4
52.4
7.3
8.7
16g
YES
Male
12
Female
Male
29g
30g
29g
30g
20
Female
Male
11
Female
4
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
■Applicable tools
Unit:mm
Description
Part number
CL No.
LF series Applicable cable dia.
5 (Note)
HR10A-TC-02 150-0041-2
Manual cable clamp crimp
LF-TC-01
150-0234-6
7.3 · 8.7
Note: Applicable cable dia. is only 5mm for LF series.
■Solder termination fixture
Part number
CL No.
Applicable connectors
LF07BP-T01
LF07BJ-T01
LF10BP-T01
LF10BJ-T01
LF13BP-T01
LF13BJ-T01
150-0232-0
150-0233-3
150-0235-9
150-0236-1
150-0237-4
150-0238-7
LF07WBP-6S,6P,3S,3P
LF07WBJ-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF10WBJ-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
LF13WBJ-20S,20P,11S,11P
■Panel Cutout
Alignment guide
unit (mm)
Shell size
LF07
A
B
Panel thickness
Ø9.05
Ø11.05
Ø14.05
8.1
0.5 to 2
0.7 to 2
0.7 to 2
LF10
10.2
13.1
LF13
B+0.05
0
■Contact position arrangement and specifications
Shell size
LF07
LF10
LF13
1
8
1
9
B
C
2
3
4
5
1
3
6
4
2
8
10
4
3
1
2
6
7
9 10
3
1
A
D
Contact configuration
5
2
11 12 13 14 15
16 17 18 19
20
3
7
12 11
2
3
2
1
4
6
4
5
5
6
7
Number of contacts
Withstanding voltage
Current rating
3
6
4
12
11
20
4
7
1250V AC
5A
300V AC
2A
1250V AC
10A
300V AC
2A
AC300V
2A
AC1250V
4
10A
AC300V
7
2A
Insulation resistance
Contact resistance
Solder pot inner diameter
1000Mø
15mø
1000Mø
5mø
1000Mø
15mø
1000Mø
1000Mø
4mø
4
7
15mø
7
5mø
4
1.15mm
0.8mm
1.7mm
0.8mm
0.8mm
Ø
Ø
1.7
0.8
Note 1: The contact configuration as viewed from the female contact connector mating side.
Note 2: The symbol indicates polarizing key position.
▼
Note 3: Withstanding voltages are test voltage values.
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
■Termination and Assembly Instructions
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.
Operation
Illustration
No.
Plug disassembly
Solder termination fixture
1
1
Plug
Insert the plug into securely held solder
termination fixture as shown.
1
Fixture Part No.
Applicable connector
LF07BP-T01 LF07WBP-6S,6P,3S,3P
LF10BP-T01 LF10WBP-4S,4P,12S,12P
LF13BP-T01 LF13WBP-20S,20P,11S,11P
Locking collar
Insertion direction
Body / insulator assembly
Backshell
Loosen the backshell turning it counter
clockwise and remove it from the body/
insulator assembly.
2
2
Solder termination fixture
Jack
Jack Disassembly
1
2
Insert the jack into the securely held solder
termination fixture as shown.
1
Fixture Part No.
Applicable connector
LF07BJ-T01 LF07WBJ-6S,6P,3S,3P
LF10BJ-T01 LF10WBJ-4S,4P,12S,12P
LF13BJ-T01 LF13WBJ-20S,20P,11S,11P
Insertion direction
Body / insulator assembly
Loosen the backshell turning it
counterclockwise.
2
Backshell
Connector Assembly
Backshell
1
2
Apply a coating of Loctite 7649
1
(Manufactured by Henckel Japan, Ltd,)
primer to the threaded sections of the
backshell and the tightening collar.
Completely dry the coated surfaces.
Note
Threaded section
Threaded section
(1)
(2)
(3)
Drying time at room temperature is
approximately 30 to 70 seconds.
Ensure sufficient ventilation of the area at
time of drying.
Take necessary steps to protect the coated
surfaces from contamination.
Tightening collar
6
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
Thread the tightening collar, strain relief collar,
seal bushing and the backshell over the cable
as illustrated.
2
2
2
Strain relief collar
Tightening collar
Backshell
Cable
Seal bushing
Cable preparation end
Cable preparation
A
1
3
Cable outer jacket
Strip the cable’s outer jacket to the dimensions
illustrated in the table 1.
1
Shielding mesh
Table 1. Stripping Dimensions
Note
(1)
(2)
Exercise caution not to damage the shielding
mesh.
Any damage to the cable’s outer jacket may
affect the waterproof performance of the
assembled connector.
Number of Conductors
3
A mm
8 to 9
6
4
12
13 to 14
14 to 15
22 to 23 (No.A to D)
23 to 24 (No.1 to 7)
23 to 24
11
20
Fold back the shielding mesh over the cable’s
outer jacket assuring that it is uniform on its
diameter.
2
2
Shielding mesh
Cable outer jacket
Wires
Shielding mesh
(Folded back)
4 to 5mm
Wires
Cable outer jacket
Stripping dimensions
Wires
3
Strip the wires to the dimensions illustrated in
the Table 2.
3
Cable outer jacket
B
Note
When stripping the wires exercise caution not
to damage it’s insulation, folded over
shielding mesh or cable’s outer jacket.
Conductors
Table 2. Stripping Dimensions
Number of Conductors
3
B mm
2.5 0.5
2
3
2
0.5
0.5
0.5
6
4
12
3
2
0.5 (No.A to D)
0.5 (No.1 to 7)
11
20
2
0.5
7
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
Soldering
4
Soldering conditions
1
Soldering iron tip temperature: 350 10ç
Soldering time: within 5 sec.
Note
(1)
Assure that the solder compound is
sufficiently melted on the soldering iron tip.
When applying, make sure that the solder will
flow correctly at all the contact surfaces
between the conductor and the contact.
(2)
Cmm
– 1
– 1 6, 12, 20, 11(No.1~7) Conductors
2
2
Wire
Insulator
(1)
Place a heat-shrink tubing (inside diameter of
1.1 mm min.) over every other wire.
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as shown.
After soldering, slide the heat shrink tubing
over the soldered joint and shrink it. The
tubing should touch the insulator as shown.
Contact
(2)
(3)
Table 3
Number of
Conductors
Number of
contacts
C mm
6
1 to 6
1 to 9
10 to 12
1 to 5,16 to 20
6 to 15
4
4
6
4
6
6
4
12
Heat-shrink tubing
20
11
1 to 4
5 to 7
Insulator
– 2 3, 4, 11(No.A~D) Conductors
2
(1)
– 2
2
Insulator wall
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as illustrated.
(2)
When soldering, to maintain the insulation
between adjacent contacts. Make sure that
the wire’s insulation remains below the edge
of the insulator’s wall 0.5 mm min., as
illustrated.
Contact
Insulator wall
Insulator
Wire insulation
Contact
Wire insulation
Solder
0.5 mm min.
3
Cable outer jacket
3
After the soldering, keep a distance of D
between the contact end and the cable’s
outer jacket as illustrated.
D
Note
Shielding mesh
(Folded back)
The distance of D is required in order to
assure correct assembly of the backshell.
Table 4. Wire Dimensions
Number of Conductors
D mm
3
6
6 to 7
4
10 to 11
13 to 14
12
11
20
18 to 19
8
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
Crimping of the Shielding Clamp
1
5
Solder termination fixture
After completion of the soldering operations
carefully remove (holding on the locking collar)
the body/insulator assembly from the solder
termination fixture.
1
Body / insulator assembly
Note
Soldered joints
Exercise caution not to damage or deform the
solder joints.
Cable outer jacket
Copper tape
2
2
Wrap the folded over shielding mesh with 5 to
6 mm wide copper tape to assure that it will
not become loose.
Cable outer jacket
Wires
Apply the copper tape so that the shielding
mesh does not protrude from under it.
Note
Shielding mesh
5 to 6mm
Copper tape
After wrapping the copper tape, the tape
should overlap itself by 2 mm max.
Insert the “U” shaped shielding clamp over the
copper tape as shown on the illustration.
It is critical that the overlap of the copper tape
is located inside the shielding clamp as shown
on the illustration.
3
3
Cable outer jacket
1 0.5mm
Copper tape
Ground clamp
Copper tape
Cable outer jacket
Note
When the end of the copper tape wrapping is
positioned at the open side of the ground
fitting, the end portion of the copper tape
wrapping will no longer be covered by the
ground fitting when the ground fitting is
crimped.
Wires
Shielding clamp
Shielding mesh
Overlap of the copper tape
4
Using commercially available pliers bend the
open ends of the shielding clamp as illustrated,
assuring that it stays in place. The dimension
of E. between opposing edges of the shielding
clamp is necessary to assure correct final
crimp.
4
Commercially
available pliers
E
Table 5
Shell size
E
Shielding clamp
Overlap of the copper tape
LF07
LF10
LF13
5mm max.
7mm max.
9
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
Crimping tool
Both sides of the shielding clamp must be
placed in the forming cavity of the tool
(as shown on the illustration) and crimped
over the cable by closing the tool completely.
5
5
5
Forming cavity
Applicable cable
diameter
Shielding clamp
Crimping tool Forming cavity
diameter after crimping
5.3mm to
5.5mm
5mm
–––
5.3
HR10A-TC-02
7.0
–––
7.9mm to
8.1mm
9.1mm to
9.3mm
7.3mm
8.7mm
7.9
LF-TC-01
9.1
Connector Assembly
1
2
6
,
Place the body/insulator assembly in the
applicable solder termination fixture.
For plug assembly
1
2
Threaded section
Backshell
Applicable connector
LF07WBP-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
Fixture Part No.
LF07BP-T01
LF10BP-T01
LF13BP-T01
For jack assembly
Fixture Part No.
LF07BJ-T01
Applicable connector
LF07WBJ-6S,6P,3S,3P
LF10WBJ-4S,4P,12S,12P
LF13WBJ-20S,20P,11S,11P
LF10BJ-T01
LF13BJ-T01
Coat the thread section of the body/insulator
assembly with Loctite 271 compound
(manufactured by Henckel Japan, Ltd.) or
equivalent, tightening it with a torque
specified in the table 6.
Wrench width : D
Table 6
Shell size Tightening torque Wrench width
·
·
1N m~1.5N m
10mm
13mm
16mm
LF07
LF10
LF13
Note
·
·
1N m~1.5N m
It is critical that the cable itself will not turn or
twist during this operation.
·
·
1.5N m~2N m
3
4
Slide forward the seal bushing and insert it in
the backshell until fully seated.
3
4
,
Seal bushing
Strain relief collar
Slide forward the strain relief collar and insert
it in the backshell, making sure that the
opposing protrusions fit inside the
corresponding grooves, as shown on the
illustration.
Protrusion
Tightening collar
Groove
Note
It is critical that the protrusions are inside the
corresponding grooves.
5
5 Verify that the Locktite 7649 primer
(or equivalent) on the threaded sections of the
backshell and tightening collar are dry.
Apply the Locktite 271 compound to the
tightening collar’s threaded section and attach
it to the backshell.
Threaded section
Tightening collar
10
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
LF Series●Miniature Waterproof Shielded Connectors
Operation
Illustration
No.
6
6
Remove the connector from the solder
termination fixture, holding it by the locking
collar. Do not pull on the cable.
Tightening collar
Wrench width
6
Shell size Tightening torque Wrench width
·
·
0.8N m~1N m
10mm
13mm
16mm
LF07
LF10
LF13
·
·
0.7N m~1N m
·
·
1 N m~1.5 N m
1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter.
2. Consult HRS representative when using different cables.
■Cable Specifications (Reference)
No. of contact
Material
3 pos.
Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire
Ø0.18 Ø0.26 Ø0.16 Ø0.16 Ø0.16
4 pos.
6 pos.
12 pos.
20 pos.
11 pos.
Soft copper wire Soft copper wire
Size (mm)
Ø0.26
Ø0.16
Construction
Size (AWG)
20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 26 /Ø0.26 mm dia. 7 /Ø0.16 mm dia.
AWG #20
AWG #16
1.25
AWG #26
–––––––
Ø0.48
AWG #26
0.14
AWG #26
0.14
AWG #16 AWG #26
Sectional area –––––––
Diameter (mm) Ø0.98
1.25
Ø1.5
0.14
Ø1.5
Ø0.48
Ø0.48
Ø0.48
Diameter (mm) Ø1.5 (Standard)
Thickness (mm) 0.26
Ø2.1 (Standard)
0.3
Ø0.88 (Standard) Ø0.9 (Standard)
0.2 0.21
Ø0.9 (Standard)
0.21
Ø2.1 (Standard) Ø0.95 (Standard)
0.3
0.235
Material
Density
Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire Soft copper wire
85%
80%
Ø5.5
85%
Ø3.4
80%
Ø4.2
80%
Ø5.1
80%
Ø6.7
Diameter (mm) Ø3.6
Diameter (mm) Ø5 0.2
Ø7.3 0.2
Ø5 0.2
Ø7.3 0.2
Ø8.7 0.2
Ø8.7 0.2
11
相关型号: