QR/P18-24PC [HRS]
Rack and Panel Connector, 24 Contact(s), Male, IDC Terminal, Plug, ROHS COMPLIANT;型号: | QR/P18-24PC |
厂家: | HRS |
描述: | Rack and Panel Connector, 24 Contact(s), Male, IDC Terminal, Plug, ROHS COMPLIANT PC 连接器 |
文件: | 总8页 (文件大小:400K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Rectangular, High-Pin-Count Rack/Panel
Insulation Displacement Connectors (IDC)
QR/P18 Series
2.5Gbps Eye Diagram
2.5Gbps
Scale
Overview
AWG#28 2m
X : 100psec/div
Y : 100V/div
The QR/P18 Series of miniature rack/panel connectors
is designed for the complete segmentation of the
structure of the external holder/terminal units of the
well-received QR/P Series of plug-in rectangular rack/
panel connectors; furthermore, the subsequent
insertion of the harnessed terminal unit affords a more
efficient harness mounting task. These connectors are
configured with 12, 18, or 24 pos.(IDC) in the signal
line, and 4 pos.(crimp) in the power line.
Fig.1
Power supply contact male unit
External holder
Power supply contact
female unit
Features
Power supply
male contacts
1. Completely separated structure of the
external holder/terminal unit
Signal contact
female unit
In order to improve the harness procedures, the
connectors are designed for the complete
segmentation of the external holder and the signal/
power supply unit, and inserting the harnessed
contacts aims to improve the workability of the power
supply/signal line harness as well as the mounting to
the set.
Panel
Power supply
female contacts
Signal contact
male unit
Fig.2
2. Signal unit
The signal unit uses the highly reliable insulation
displacement connection method. (The wire is AWG
#26 and the insulation outter diameter is 0.88 mm.)
The insulation displacement procedure can now be
used by attaching a special applicator to a
commercially available automatic insulation
displacement machine, or a manual press tool can
also be selected.
3. Power supply
The power supply terminals permit the use of a
crimp harness using wire of AWG#16 to 18 (and
insulation outside diameter of 2.1 to 2.2 mm), and
can accommodate a maximum of 12 A.
4. Sequential mating structure
Two sequential contacts in the signal male unit and
one sequential contact in the power supply female unit
are provided for safety operation.
5. Panel installation
Installation to a panel uses a single-action method
on the anchored side and a floating screw structure
on the floating side which permits smooth insertion
and disconnection without forcing.
1
2015.1w
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
Product Specifications
■
125V AC (Signal contacts)
300V AC (Power contacts)
Voltage rating
-40°C to +105°C
(Note 1)
Ratings
Operating temperature range
1A (Signal contacts)
12A (Power contacts)
Current rating
Item
Specification
Conditions
50mø max. (Signal contacts) (Note 2)
10mø max. (Power contacts) (Note 2)
1. Contact resistance
2. Insulation resistance
100mA MAX (DC or 1000Hz)
1000Mø min. (Signal contacts)
5000Mø min. (Power contacts)
500V DC
3. Withstanding Voltage No flashover or insulation breakdown.
500V AC / one minute
3000 cycles
4. Durability
Contact resistance: 70mø max. (Signal contacts)
20mø max. (Power contacts)
(mating / un-mating)
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours in each of the 3 axis.
Acceleration of 490 m/s2, 11 ms duration, sine half-
wave waveform, 3 cycles in each of the 3 axis
5. Vibration
6. Shock
No electrical discontinuity of 10µs or more.
No damage, cracks or parts dislocation.
Contact resistance: 70mø max. (Signal contacts)
20mø max. (Power contacts)
No damage, cracks or parts dislocation.
Temperature: -55ç +5 to +35ç +105ç +5ç to +35ç
➝ ➝ ➝
7. Temperature cycle
Time: 30
5 cycles
5
30 5 (Minutes)
➝ ➝
➝
Insulation resistance:
8. Humidity
(Steady state)
100Mø min. (Signal contacts, state)
3000Mø min. (Power contacts, state)
No damage, cracks or parts dislocation.
96 hours at 40ç and RH 90% to 95%
5% salt water solution for 48 hours
9. Salt mist
No HEAVY corrosions.
Note1: Includes temperature rise caused by current flow.
Note2: Excludes wire conductor resistance.
Materials
Product
■
Components
Insulator
Material
PBT
Finish
−−−−−
−−−−−
Remarks
External holder
UL94V-0
Insulator
PA
−−−−−
−−−−−
Signal contact unit
Power contact unit
Female contacts
Male contacts
Insulator
Phosphor bronze
PBT
Gold plated
−−−−−
UL94V-0
−−−−−
Female contacts
Male contacts
Power supply contacts
Copper alloy
Gold plated + Tin copper plated
−−−−−
Function Diagram
■
Power supply/signal combination type
QR/P18-S*4P-* QR/P18-P*4S
QR/P17-PCA-*11(50) QR/P18-4P-C
QR/P18-4S-C QR/P17-SCA-*11(50)
QR/P18-*S*
QR/P18-*P*
Signal type
QR/P18-S*-* QR/P18-P*
QR/P18-*P*
QR/P18-*S*
2
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
Product Number Structure
External holder
QR / P18 - S A 4 P - A
❶
❷
❸
❹
❺
❻
Series name
Number of power contact
q
w
r
t
Signal contact type S: Female contact
P: Male contact
Power contact type S: Female contact
P: Male contact
Applicable panel thickness
A: 2mm
y
Number of signal contact of external holder
e
A: 12 pos. (Contact pitch 1.5mm)
B: 18 pos. (Contact pitch 1.5mm)
C: 24 pos. (Contact pitch 1.5mm)
B: 1.5mm
Signal Unit
QR / P18 - 12 S A
❶
❷
❸
❹
Series name
Signal unit size
r
q
w
A: 12 pos. (Contact pitch 1.5mm)
B: 18 pos. (Contact pitch 1.5mm)
C: 24 pos. (Contact pitch 1.5mm)
Number of signal contact
Signal contact type S: Female contact
P: Male contact
e
Power Unit
QR / P18 - 4 P - C
❶
❷
❸
❹
Series name
Connector type
r
C: Crimp housing
q
w
Number of power contact
Power contact type S: Female contact
P: Male contact
e
Power contact
QR / P17 - PC A - 1 1 1
❶
❷
❸
❹
❺
❻
Series name
q
w
Packaging
1: Pack packaging
2: Reel packaging
r
Power contact type PC: Male crimp contact
SC: Female crimp contact
Applicable wire
Contact plating
1: AWG#16 to 18
1: Gold plated
t
y
Applicable wire style A: UL1015
e
3
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
External holder
Mated condition (Shown for reference)
Panel
Panel
QR/P18-Sπ4P-A
QR/P18-Pπ4S
Note: Distance between the
QR/P15-SCREW
2
power supply side and
the signal side when fully
mated must be 1.5mm
max.
23
2
26.5
2.5
5.1
7.4
6.15
29
Applicable panel thickness: 2.0mm
Female power contact, male signal contact type
Panel cutout
A
B
(2)
20.7
2-M3∞0.5
10.5
13.9
Die roll side should be
connector mating side.
No. of contacts
Part No.
HRS No.
A
B
C
D
Signal
12
Power
QR/P18-PA4S
QR/P18-PB4S
QR/P18-PC4S
221-0293-8
221-0313-3
221-0297-9
54.65
58.65
63.15
46.25
50.25
54.75
27.2
31.2
35.7
18
4
24
Panel attachment screw (QR/P15-SCREW 221-0251-8) is optional.
Applicable panel thickness: 2.0mm
Male power contact, female signal contact type
Panel cutout
2
A
2.5
19
10
4-R0.3
Die roll side should be
connector mating side.
13.65
No. of contacts
Part No.
HRS No.
A
B
C
D
Signal
Power
QR/P18-SA4P-A
QR/P18-SB4P-A
QR/P18-SC4P-A
221-0294-0
221-0315-9
221-0298-1
12
18
24
43.85
47.85
52.35
37.9
41.9
46.4
27.25
31.25
35.75
17.3
21.3
25.8
4
4
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
External holder (Signal type)
Mated condition (Shown for reference)
QR/P18-Sπ-B
QR/P18-Pπ
Panel
Note: Distance between the
QR/P15-SCREW
power supply side and
the signal side when fully
mated must be 1.5mm
max.
1.5
5.1
1.5
15
2.5
3
17.5 7.4
Applicable panel thickness: 1.5mm
Male signal contact type
Panel cutout
(15)
t=1.5
C
2-M3∞0.5
D
E
Die roll side should be
connector mating side.
B
A
No. of contacts
Signal
Part No.
HRS No.
A
B
C
D
E
QR/P18-PB
QR/P18-PC
221-0309-6
221-0311-8
18
24
37.7
42.2
29.5
34
27
23.5
28
29.5
34
31.5
Panel attachment screw (QR/P15-SCREW 221-0251-8) is optional.
Applicable panel thickness: 1.5mm
Female signal contact type
Panel cutout
(13.05) t=1.5
D
C
1.75
B
Die roll side should be
connector mating side.
A
2.5
No. of contacts
Signal
Part No.
HRS No.
A
B
C
D
QR/P18-SB-B
QR/P18-SC-B
221-0310-5
221-0312-0
18
24
28.05
32.55
25.1
29.6
13
7.3
15.25
11.8
5
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
Signal Unit
Male, contact pitch 1.5mm
15
Sequence contact
Part No.
HRS No.
No. of contacts
A
B
14
18
QR/P18-12PA
QR/P18-18PB
QR/P18-24PC
221-0291-2
221-0285-0
221-0295-3
12
18
24
13.5
17.5
22
22.5
Sequence contact
Adscable cable: AWG#26, insulator diameter 0.88mm
Female, contact pitch 1.5mm
Part No.
HRS No.
No. of contacts
A
B
14
18
QR/P18-12SA
QR/P18-18SB
QR/P18-24SC
221-0292-5
221-0286-2
221-0296-6
12
18
24
13.5
17.5
22
15
22.5
Applicable cable: AWG#26, insulator diameter 0.88mm
Power Unit
Male
15.9
17.9
Part No.
HRS No.
QR/P18-4P-C
221-0316-1
Sequence contact(No.4)
Female
13.5
16.2
Part No.
HRS No.
QR/P18-4S-C
221-0314-6
6
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
Power contact
Male contact
3
Applicable
wire size
16-18
Part No.
QR/P17-PCA-111(50)
QR/P17-PCA-211(50)
HRS No.
221-0265-2 50
221-0263-7 50
Applicable cable
Packaging
Pack
Q'ty
100
3000
AWG#16 to 18 UL1015
Reel
Applicable cable: AWG#16 to 18, insulator diameter 2.1mm to 3.2mm
4
Female contact
Applicable wire size
Part No.
QR/P17-SCA-111(50)
QR/P17-SCA-211(50)
HRS No.
221-0264-0 50
221-0262-4 50
Applicable cable
Packaging
Pack
Q'ty
100
3000
AWG#16 to 18 UL1015
Reel
Applicable cable: AWG#16 to 18, insulator diameter 2.1mm to 3.2mm
Tools
Signal contact termination block IDC tool
Insulation displacement connection
Press
Applicable connector
QR/P18-12PA
QR/P18-12SA
QR/P18-18PB
QR/P18-18SB
QR/P18-24PC
QR/P18-24SC
IDC unit
QR/P18-12UNIT
902-2147-6
QR/P18-18UNIT
902-2145-0
Tool body
HOS-7
902-0132-8
QR/P18/IDCR-MP
902-2144-8
QR/P18-24UNIT
902-2148-9
Automatic IDC machine (Murata kogyo co., Ltd., P/N MS-01) is available.
Power contact crimp tool
Manual
Applicable contact
QR/P17-PCA-111(50)
QR/P17A-SCA-211
Manual crimping tool
HT104/QR/P17-1
250-0238-5
Automatic
Applicable contact
QR/P17-PCA-211(50)
QR/P17A-SCA-211
Automatic crimping machine body
CM-105
Applicator
AP105-QR/P17-1
901-2579-4
901-0005-4
Extraction tool
Applicable contact
QR/P17-PCA-111(50)
QR/P17A-SCA-111
QR/P17-PCA-211(50)
QR/P17A-SCA-211
Extraction tool
QR/P17-TC
250-0237-2
7
QR/P18 Series●Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)
Inspection After Cable Wiring
Signal contact unit
Signal contact unit (male)
Signal contact unit (female)
Cable
B
Cable
A
A
B
±~±.5
±~±.5
Cable end position
Cable end position
A-A
B-B
Insulation displacement height
Insulation displacement height
Insulation height
Insulation height
(1) After wiring the cable, examine the cable end position, the insulation displacement height, and the insulation height.
(2) In examining the insulation displacement height and the insulation height, use a measurement pin having a tip of 0.5 mm diameter.
(3) For information about the detailed inspection method, please request the "Inspection Standards Manual" from Hirose Electric.
(4) The inspection method of the diagrams is for cable with AWG#26 wire and an insulation outside diameter of 0.88 mm.
Power supply contacts
Male contact
Female contact
Cable
Cable
Spring
Spring
®
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
+
+
TEL: 81-45-620-3526 Fax: 81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 1/2015. Contents are subject to change without notice for the purpose of improvements.
8
相关型号:
©2020 ICPDF网 联系我们和版权申明