GBU3504 [HY]
Glass Passivated Bridge Rectifiers;型号: | GBU3504 |
厂家: | HY ELECTRONIC CORP. |
描述: | Glass Passivated Bridge Rectifiers |
文件: | 总3页 (文件大小:431K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
www.hygroup.com.tw
GBU35005 THRU GBU3510
Reverse Voltage - 50 to 1000 Volts
Forward Current - 35 Amperes
Glass Passivated Bridge Rectifiers
Features
● Glass passivated chip
GBU
● Low forward voltage drop
● Ideal for printed circuit board
● High surge current capability
RoHS
COMPLIANT
●Meet UL flammability classification 94V-0
Mechanical Data
● Polarity: Symbol marked on body
● Mounting position: Any
Note: Products with logo
or
are made by HY Electronic (Cayman) Limited.
Applications
● General purpose use in AC/DC bridge full wave rectification,
for SMPS, lighting ballaster, adapter, etc.
Dimensions in inches and (milimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
GBU
35005
50
GBU
3501
100
70
GBU
3502
200
GBU
3504
400
280
400
35.0
4.2
GBU
3506
600
GBU
3508
800
GBU
3510
1000
700
Characteristics
Symbol
Unit
V
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
35
140
420
560
V
V
Maximum DC Blocking Voltage
50
100
200
600
800
1000
Maximum Average Forward (with heatsink Note 2)
Rectified Current @ TC=100℃ (without heatsink)
Peak Forward Surge Current, 8.3mS Single Half Sine-Wave,
Superimposed on Rated Load (JEDEC Method)
I(AV)
A
A
IFSM
350
I2t Rating for Fusing (t<8.3mS)
I2t
A2s
V
508
1.1
Peak Forward Voltage per Diode at 17.5A DC
Maximum DC Reverse Current at Rated @TJ=25℃
DC Blocking Voltage per Diode @TJ=125℃
Typical Junction Capacitance per Diode (Note1)
Typical Thermal Resistance to case (Note2)
Operating Junction Temperature Range
Storage Temperature Range
VF
5.0
IR
μA
500
70
CJ
RθJC
TJ
pF
℃/W
℃
2.2
-55 to +150
-55 to +150
TSTG
℃
Notes: 1. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC.
2.Device mounted on 100mm*100mm*1.6mm Cu plate heatsink.
3.The typical data above is for reference only
GBU35*-U-00/99-00/01
Rev. 11, 18-May-2020
Rating and Characteristic Curves
GBU35005 THRU GBU3510
Fig. 1 - Forward Current Derating Curve
35
Fig. 2 - Maximum Non-Repetitive Surge Current
400
350
300
250
200
150
100
50
With heatsink
30
8.3mS Single Half-Sine-Wave
(JEDEC METOD)
25
20
15
10
Without heatsink
5
0
0
0
50
100
150
1
10
100
Case Temperature (℃)
Fig. 3 - Typical Reverse Characteristics
TJ=150°C
Number of Cycles at 60Hz
Fig. 4 - Typical Forward Characteristics
25
10
1000
100
10
Pulse Width 300uS
2%Duty Cycle
TJ=125°C
TJ=100°C
TJ=75°C
TJ=100°C
TJ=25°C
1
TJ=125°C
1
TJ=75°C
TJ=25°C
0.1
0.1
20
40
60
80
100
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Percent of Rated Peak Reverse Voltage (%)
Instantaneous Forward Voltage (V)
The curve above is for reference only.
GBU35*-U-00/99-00/01
Rev. 11, 18-May-2020
Legal Disclaimer Notice
Disclaimer
ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons.
HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co-
tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising
out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d-
amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch-
antability.
Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require-
ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi-
lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specific-
ations may vary in different applications and performance may vary over time. All operating parameters, including typical paramet-
ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or
otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applicati-
ons or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or
selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY pers-
onnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any
conduct of HY. Product names and markings noted herein may be trademarks of their respective owners.
Rev. 11, 18-May-2020
相关型号:
©2020 ICPDF网 联系我们和版权申明