SQ1240_V01 [HY]

Photovoltaic Solar Cell Protection Schottky Diode;
SQ1240_V01
型号: SQ1240_V01
厂家: HY ELECTRONIC CORP.    HY ELECTRONIC CORP.
描述:

Photovoltaic Solar Cell Protection Schottky Diode

文件: 总3页 (文件大小:263K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
www.hygroup.com.tw  
SQ1240 THRU SQ1245  
Reverse Voltage - 40 to 45 Volts  
Forward Current - 12 Amperes  
Photovoltaic Solar Cell Protection  
Schottky Diode  
Features  
DO- 27  
Low power loss, high efficiency  
High current capability, low VF  
High surge capacity  
RoHS  
COMPLIANT  
Mechanical Data  
TC measurement point  
Case: JEDEC DO-27 molded plastic  
Polarity: Color band denotes cathode  
Mounting position: Any  
Note: Products with logo  
or  
are made by HY Electronic (Cayman) Limited.  
Applications  
For use in solar cell junction box as a bypass diode  
Package Outline Dimensions in Inches (Millimeters)  
Maximum Ratings and Electrical Characteristics  
Rating at 25ambient temperature unless otherwise specified.  
Single phase, half wave, 60Hz, resistive or inductive load.  
For capacitive load, derate current by 20%.  
SQ1240  
40  
SQ1245  
45  
Characteristics  
Maximum Repetitive Peak Reverse Voltage  
Maximum RMS Voltage  
Symbol  
Unit  
V
VRRM  
VRMS  
VDC  
28  
31.5  
45  
V
40  
Maximum DC Blocking Voltage  
V
12  
I(AV)  
A
Maximum Average Forward Rectified Current @Tc=95  
Peak Forward Surge Current, 8.3mS Single Half Sine-Wave,  
Superimposed on Rated Load (JEDEC Method)  
Peak Forward Voltage at 12A DC (Note1)  
Maximum DC Reverse Current @TJ=25℃  
at Rated DC Bolcking Voltage @TJ=100℃  
Typical Junction Capacitance (Note2)  
Typical Thermal Resistance Junction to Case  
Junction Temperature Range  
IFSM  
VF  
300  
A
V
0.55  
0.5  
IR  
mA  
50  
450  
CJ  
RθJC  
TJ  
pF  
/W  
3.0  
-55 to+200  
-55 to+200  
Storage Temperature Range  
TSTG  
Notes: 1. 300uS pulse width, 2%duty cycle.  
2. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC.  
3. The typical data above is for reference only .  
SQ12*-A-00/B-00  
Rev. 11, 18-May-2020  
Rating and Characteristic Curves  
SQ1240 THRU SQ1245  
Fig. 1 - Forward Current Derating Curve  
14  
Fig. 2 - Maximum Non-Repetitive Surge Current  
350  
300  
250  
200  
150  
100  
50  
12  
10  
8
8.3mS Single Half-Sine-Wave  
(JEDEC METOD)  
6
4
2
0
0
50  
100  
150  
200  
0
1
10  
100  
Case Temperature ()  
Number of Cycles at 60Hz  
Fig. 4 - Typical Forward Characteristics  
Fig. 3 - Typical Reverse Characteristics  
20  
10  
100  
10  
TJ=125°C  
Pulse Width  
300uS 2%Duty  
Cycle  
TJ=100°C  
TJ=75°C  
TJ=100°C  
TJ=25°C  
1
TJ=125°C  
1
TJ=25°C  
0.1  
0.01  
TJ=75°C  
0.1  
20  
40  
60  
80  
100  
0
0.2  
0.4  
0.6  
0.8  
1
Instantaneous Forward Voltage (V)  
Percent of Rated Peak Reverse Voltage (%)  
Fig. 5 - Typical Junction Capacitance  
1000  
100  
10  
TJ=25°C,f=1MHz  
1
0.1  
1
10  
100  
Reverse Voltage (V)  
The curve above is for reference only.  
SQ12*-A-00/B-00  
Rev. 11, 18-May-2020  
Legal Disclaimer Notice  
Disclaimer  
ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons.  
HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co-  
tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising  
out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d-  
amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch-  
antability.  
Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require-  
ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi-  
lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties  
described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specific-  
ations may vary in different applications and performance may vary over time. All operating parameters, including typical paramet-  
ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or  
otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein.  
Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applicati-  
ons or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or  
selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY pers-  
onnel to obtain written terms and conditions regarding products designed for such applications.  
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any  
conduct of HY. Product names and markings noted herein may be trademarks of their respective owners.  
Rev. 11, 18-May-2020  

相关型号:

SQ1245

SCHOTTKY BARRIER RECTIFIERS
HY

SQ1250

SCHOTTKY BARRIER RECTIFIERS
HY

SQ1260

SCHOTTKY BARRIER RECTIFIERS
HY

SQ1280

SCHOTTKY BARRIER RECTIFIERS
HY

SQ131N31

Flexible Small Channel Count Switch Module
JDSU

SQ131N32

Flexible Small Channel Count Switch Module
JDSU

SQ131N37

Flexible Small Channel Count Switch Module
JDSU

SQ131N41

Flexible Small Channel Count Switch Module
JDSU

SQ131N42

Flexible Small Channel Count Switch Module
JDSU

SQ131N47

Flexible Small Channel Count Switch Module
JDSU

SQ131Y31

Flexible Small Channel Count Switch Module
JDSU

SQ131Y32

Flexible Small Channel Count Switch Module
JDSU