AOW110-S 概述
Honeywell ZephyrTM Digital Airflow Sensors
AOW110-S 数据手册
通过下载AOW110-S数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载ø22mm - TW Series
Switches & Pilot Devices
TW Series — 22mm NEMA Style Pushbuttons
Key features:
• TW NEMA Style Switches with snap-on contacts
• Corrosion resistant octagonal chrome plated locking bezel
• Snap-on 10A contact blocks
IDEC has your 22mm switching needs covered.
Button styles include flush, extended, mushroom, or square and all bodies are
crafted from fracture-resistant nylon.
• LED illumination
• Slow make, double break, contacts
All illuminated units feature two lens styles, one that maximizes light dispersion,
the other accommodates direct lens engraving.
• Modular construction for maximum flexibility
• Type 4X and IP65 watertight/oiltight panel
• Available assembled or as sub-components
• Finger-Safe - Spring-Up
Contact mechanism allow for a wide current rating, 5mA to 10A, which reduces
the need for various contact materials.
When looking for a 22mm switch that is durable, easy to use, and versatile, then
IDEC’s TW series is your solution.
• Large M3.5 screw terminals with captive sems plate
UL Listed
File No. E68961
CSA Approved
File No. LR21451
Certificate No.
2030010305027380
File No. DK95-01696
1904032203
www.IDEC.com
696
ø22mm - TW Series
Switches & Pilot Devices
Conforming to Standards
Approvals
EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Certificate No.
2030010305027380
File No. E68961
File No. LR21451
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot
lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Registration No: J9551802 (E-Stops)
Registration No: J9551803 (All other switches)
Registration No: J9551804 (Pilot Lights)
Operating Temperature
Vibration Resistance
Shock Resistance
Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing)
5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6
1000m/sec2 (100g) conforming to IEC6068-2-7
Electric Shock Protection
Class 2 conforming to IEC60664-7
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
IP65 from front of the panel; (IP54 for key switches)
IP20 (Type HW-U contact block)
Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches)
Momentary pushbuttons: 5,000,000 (1800 operations per hour)
All other switches: 500,000
Mechanical Life
Pollution Degree (conforming to IEC60947-1)
3
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
Rated Operational Characteristics
Rated Insulation Voltage
Rated Switching Over-Voltage
Rated Impulse Withstanding Voltage
Rated Thermal Current
600V
Less than 4kV, conforming to IEC60947-1
4kV for contact circuit, 2.5kV for lamp circuit
10 Amp
Minimum Switching Capacity
Contact Operation
5 mA at 3V AC/DC
Slow break NC or slow make NO, self-cleaning
Recommended Tightening
Unit
Wire
Number of Wires
Terminal Screw
M3.5
Torque (Nm)
1.0 to 1.3
1.0 to 1.3
1.2 to 1.3
1.0 to 1.3
1.2 to 1.3
Crimping Terminal
2
2
1
2
1
ø0.5 to 1.6 mm (AWG14 to 22)
ø1.7 to 2.0 mm (AWG12)
0.3 to 2.0 mm2 (AWG14 to 22)
2.1 to 3.5 mm2 (AWG12)
Crimping Terminal
Solid Wire
HW-U Contact Block
Recommended Terminal Torque
Stranded Wire
Solid Wire
ø0.5 to 1.6 mm (AWG14 to 22)
Illuminated Unit (*1)
Pilot Light
2
2
1.0 to 1.3
M3.5
Stranded Wire
0.3 to 2.0 mm (AWG14 to 22)
Crimping Terminal
0.6 to 1.0 (M3.0)
1.0 to 1.3 (M3.5)
Applicable Wire Size
Solid Wire
ø0.5 to 1.6 mm (AWG14 to 22)
ø0.3 to 2.0 mm (AWG14 to 22)
Stranded Wire
1. * refers to the lamp terminals of the illuminated push buttons and selector switches.
External Short-Circuit Protection
Applicable Wire Size
10A 250V fuse conforming to IEC60269-1
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Contact Resistance
Contact Gap
Initial contact resistance of 50mΩ or less
4mm (NO and NC), 2mm (NO-EM and NC-LB)
MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Electrical Reliability
Lamp Ratings
LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max
Horsepower Rating
Contact Material
1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor)
Silver
Contact Block
Type HW-U
600V
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Rated Insulation Voltage
Rated Continuous Current
10A
Illuminated Selector Switches
Pushbutton Selectors
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Contact Ratings by Utilization Category
Operational Voltage
24V
10A
10A
10A
5A
48V
—
—
5A
2A
50V
10A
7A
110V
10A
5A
220V
6A
440V
AC-12 Control of resistive loads and solid state loads
AC-15 Control of electromagnetic loads (> 72VA)
DC-12 Control of resistive loads and solid state loads
DC-13 Control of electromagnets
2A
1A
—
—
AC50/60Hz
3A
Operational Current
—
2.2A
1.1A
1.1A
0.6A
DC
—
1904032203
800-262-IDEC (4332) • USA & Canada
697
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Pushbuttons (Assembled)
Assembled Pushbuttons
A
B
(
)
W
1
10
–
B
Function
Button Color
B: Momentary
O: Maintained
B: Black
R: Red
G: Green
S: Blue
W:White
Y: Yellow
K: Key On/Off Lock
Bezel Shape
Blank: Octagonal
F: Full Shroud
G: Mushroom Shroud
Q: Square
Contact Arrangement
10: 1NO
20: 2NO
01: 1NC
02: 2NC
11: 1NO-1NC 22: 2NO-2NC
Button Shape
1: Flush
2: Extended
3: Mushroom Head Ø 29mm
4: Mushroom Head Ø 40mm
Series Designation
W: TW Series
To be used for interpreting part numbers only, not for part number development.
1904032203
www.IDEC.com
698
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Pushbuttons (Assembled) continued
Non-Illuminated Pushbuttons
jButton Color Codes
Style
Contacts Momentary Action
Maintained Action
Color
Black
Green
Red
Code
B
G
R
1NO
ABW110-j
ABW101-j
ABW111-j
ABW120-j
ABW102-j
AOW110-j
AOW101-j
AOW111-j
AOW120-j
AOW102-j
1NC
Flush
1NO-1NC
2NO
2NC
Blue
S
Yellow
White
Y
1NO
1NC
1NO-1NC
2NO
2NC
ABW210-j
ABW201-j
ABW211-j
ABW220-j
ABW202-j
AOW210-j
AOW201-j
AOW211-j
AOW220-j
AOW202-j
W
Extended
Recessed
1NO
1NC
1NO-1NC
2NO
2NC
ABFW110-j
ABFW101-j
ABFW111-j
ABFW120-j
ABFW102-j
AOFW110-j
AOFW101-j
AOFW111-j
AOFW120-j
AOFW102-j
1NO
1NC
1NO-1NC
2NO
2NC
ABFW210-j
ABFW201-j
ABFW211-j
ABFW220-j
ABFW202-j
AOFW210-j
AOFW201-j
AOFW211-j
AOFW220-j
AOFW202-j
Extended with Full
Shroud
1NO
1NC
1NO-1NC
2NO
2NC
ABW310-j
ABW301-j
ABW311-j
ABW320-j
ABW302-j
AOW310-j
AOW301-j
AOW311-j
AOW320-j
AOW302-j
Ø 29mm
Mushroom Head
1NO
1NC
1NO-1NC
2NO
2NC
ABW410-j
ABW401-j
ABW411-j
ABW420-j
ABW402-j
AOW410-j
AOW401-j
AOW411-j
AOW420-j
AOW402-j
Ø 40mm
Mushroom Head
1NO
1NC
1NO-1NC
2NO
2NC
ABGW410-j
ABGW401-j
ABGW411-j
ABGW420-j
ABGW402-j
AOGW410-j
AOGW401-j
AOGW411-j
AOGW420-j
AOGW402-j
Ø 40mm
Mushroom Head
with Full Shroud
1NO
1NC
1NO-1NC
2NO
2NC
ABQW110-j
ABQW101-j
ABQW111-j
ABQW120-j
ABQW102-j
AOQW110-j
AOQW101-j
AOQW111-j
AOQW120-j
AOQW102-j
Square Flush
1NO
1NC
1NO-1NC
2NO
2NC
ABQW210-j
ABQW201-j
ABQW211-j
ABQW220-j
ABQW202-j
AOQW210-j
AOQW201-j
AOQW211-j
AOQW220-j
AOQW202-j
Square Extended
1NO
1NC
1NO-1NC
2NO
2NC
AKW210
AKW201
AKW211
AKW220
AKW202
Keylock Push On/
Off
–
1. In place of j, specify the Button Color Code from table.
2. For sub-assembled part numbers, see next page.
3. For accessories, see page 728.
4. For dimensions, see page 730.
5. Keyed switches are supplied with two keys. All units are keyed alike.
1904032203
800-262-IDEC (4332) • USA & Canada
699
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Pushbuttons (Sub-Assembled)
Contact Blocks
+
Operator
+
Button
=
Complete Part
Operators
Buttons
Contact Blocks
Part Number
Momentary Maintained
Style
Part Number
Style
Contacts 1NO
1NC
Style
Round Flush
Finger-
Safe
HW-U10-F
HW-U01-F
Round Flush/Extended
Spring-Up
Terminal
HW-U10R-F HW-U01R-F
(early make) (late break)
ABW1B-j
ABW2B-j
ABW3B-j
ABW4B-j
ABQW1B-j
ABQW2B-j
ABW-100
AOW-100
Dummy
Block
HW-DB
Round Extended
Ø 29mm Mushroom
Ø 40mm Mushroom
Square Flush
Round with Full
Shroud/Recessed
1. Dummy blocks (no contacts) are used with an odd
number of contact blocks.
2. Use of early and late break contacts creates a make
before break function
ABFW-200
AOFW-200
jButton Color Codes
Ø 40mm, Ø 29mm
Mushroom Head
Color
Black
Green
Red
Code
B
G
R
ABW-300
AOW-300
Blue
S
Yellow
White
Y
Ø 40mm Mushroom
Head with Full Shroud
W
ABGW-400
AOGW-400
Square Flush/Extended
Keylock Push On/Off
ABQW-100
AOQW-100
AKW-200
Square Extended
—
In place of jspecify the button color code from table
1904032203
www.IDEC.com
700
ø22mm - TW Series
Switches & Pilot Devices
Stop Switches (Assembled)
To be used for interpreting part numbers only, not for part number development.
Assembled Stop Switches
(B) (99) 11 (D) – R – (24V)
A
V
(L)
W
4
Function
Lamp Voltage
(full voltage illuminated units only)
V: Pushlock Turn Reset
Y: Push-Pull
X: Pushlock Key Reset
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC
240V: 240V AC
Illumination
Blank: None
L: Illuminated
Button/Lens Color
A: Amber R: Red W: White
G: Green S: Blue Y: Yellow
B: Black
Series Designation
W: TW Series
Button/Lens Size
3: 29mm Mushroom
4: 40mm Mushroom
Lamp Type
(illuminated units only)
Lens Type
(illuminated units only)
D: LED
Blank: Standard (ribbed)
B: Engravable (smooth with insert)
Contact Arrangement
Illuminated Circuit
(illuminated unit only)
10:1NO
20:2NO
01:1NC
02:2NC
11:1NO/1NC 22:2NO/2NC
99: Full Voltage (LED determines voltage)
126: 120V AC Step Down Transformer
246: 240V AC Step Down Transformer
486: 480V AC Step Down Transformer
1904032203
800-262-IDEC (4332) • USA & Canada
701
ø22mm - TW Series
Switches & Pilot Devices
Stop Switches (Assembled), continued
Non-Illuminated Stop Switches
jButton Color Codes
Style
Contacts
Part Number
Color
Black
Green
Red
Code
B
G
R
1NO
1NC
1NO-1NC
2NO
2NC
AVW410-R*
AVW401-R*
AVW411-R*
AVW420-R*
AVW402-R*
Ø 40mm Pushlock
Turn Reset*
Blue
S
White
Yellow
W
Y
1NO
1NC
1NO-1NC
2NO
2NC
AVW310-R*
AVW301-R*
AVW311-R*
AVW320-R*
AVW302-R*
Ø 29mm Pushlock
Turn Reset*
kLED/Lens Color Codes
Color
Amber
Green
Red
Code
A
G
1NO
1NC
1NO-1NC
2NO
2NC
AYW410-j
AYW401-j
AYW411-j
AYW420-j
AYW402-j
Ø 40mm Push-Pull
R
Blue
S
White
W
1NO
1NC
1NO-1NC
2NO
2NC
AXW410- R*
AXW401- R*
AXW411- R*
AXW420- R*
AXW402- R*
lFull Voltage Codes
Ø 40mm Pushlock
Key Reset *
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Code
6V
12V
1. *Available in Red only.
2. In place of j, specify the Button Color Code from table.
3. For sub-assembled part numbers, see next page.
4. For accessories, see page 728.
24V
120V
240V
5. For dimensions, see page 730.
240V AC
Illuminated Stop Switches
mTransformer Voltage Codes
Style
Type
Contacts
Part Number
Voltage
Code
1NO-1NC
2NO
2NC
AVLW4 m11D-R*
AVLW4 m20D-R*
AVLW4 m02D-R*
120VAC
240VAC
480VAC
126
246
486
Transformer
Ø 40mm Pushlock
Turn Reset Type
1NO-1NC
2NO
2NC
AVLW49911D-R*-l
AVLW49920D-R*-l
AVLW49902D-R*-l
Transformers step down to 6V.
Full Voltage
Transformer
Full Voltage
Transformer
1NO-1NC
2NO
2NC
AVLW3m11D-R*
AVLW3m20D-R*
AVLW3m02D-R*
Ø 29mm Pushlock
Turn Reset
1NO-1NC
2NO
2NC
AVLW39911D-R*-l
AVLW39920D-R*-l
AVLW39902D-R*-l
1NO-1NC
2NO
2NC
AYLW4 m11D-k
AYLW4 m20D-k
AYLW4 m02D-k
Ø 40mm Push-Pull
1NO-1NC
2NO
2NC
AYLW49911D-k-l
AYLW49920D-k-l
AYLW49902D-k-l
Full Voltage
1. *Available in red only.
2. In place of k, specify the Lens Color Code (see table above).
3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above).
4. In place of m, specify the Transformer Voltage Code (see table above).
5. For sub-assembly part numbers, see next page.
6. For accessories, see page 728.
7. For dimensions, see page 730.
1904032203
www.IDEC.com
702
ø22mm - TW Series
Switches & Pilot Devices
Stop Switches (Sub-Assembled)
Transformer/
Adaptor*
+
Contacts
+
Lamp Holder
+
Operator
+
Lamp
+
Button or Lens
=
Complete Part
*Not applicable for full voltage units
Operators
Buttons
Lamps
Part Number
Style
Part Number
Style
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Part Number
LSTD-6k
Style
Non-Illuminated Illuminated
Ø 40mm Pushlock Turn Reset
LED
LSTD-1k
Ø 29/Ø 40mm
Pushlock Turn Reset
LSTD-2k
AVW4B-R*
AVW-300
AYW-400
AVLW3-0600
AYLW4-0600
LSTD-H2k
LSTD-M4k
240V AC
1. In place of k, specify the LED color code.
2. The LED contains a current-limiting resistor and a
protection diode.
Ø 29mm Pushlock Turn Reset
Ø 40mm Push-Pull
AVW3B-R*
AYW4B-j
AXW4B-R*
jButton Color Codes
Color
Black
Green
Red
Code
B
G
R
Ø 40mm Push-Pull
Ø 40mm Pushlock
Key Reset
Blue
S
AXW-300
—
White
Yellow
W
Y
Ø 40mm Pushlock Key Reset
kLED/Lens Color Codes
Color
Amber
Green
Red
Code
A
G
1. *Available in Red only
2. In place of j, specify the button color code from table.
R
Blue
S
White
W
1904032203
800-262-IDEC (4332) • USA & Canada
703
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Stop Switches (Sub-Assembled) continued
Lenses
Transformers/Full Voltage Modules
Part Number
Style
Description
120V AC
Part Number
Style
Standard
Engravable
Full Size Transformer
TW-F126B
Ø 29mm Head Pushlock Turn Reset
240V AC
480V AC
TW-F246B
TW-F486B
AVLW3LU-R*
AVLW4LU-R*
AVLW3BLU-R*
Finger-Safe
Ø 40mm Head Pushlock Turn Reset
Ø 40mm Head Push Pull
For use
AVLW4BLU-R*
Dummy Block with
Full Voltage Adaptor
with odd
number of
contacts.
Finger-Safe
HW-DA1FBN
TW-DA1FB
For use
with even
number of
contacts.
Full Voltage Adaptor
Finger-Safe
AYLW4LU-k
AYLW4BLU-k
All Transformers step down to 6V (use 6V LED).
Contact Blocks
Style
1. In place of k, specify the lens color code from table on previous page.
2. *Available only in red
3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an
engravable insert.
Contacts 1NO
1NC
Finger-
Safe
HW-U10-F
HW-U01-F
Spring-Up
Terminal
HW-U10R-F HW-U01R-F
(early make) (late break)
Lamp Circuit Components
Style
Application
Part Number
Long Lamp Holder
Dummy
Block
HW-DB
Used with Full-size
Transformer and two
contact blocks
TW-LH2
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
Lead Holder
Used with TW-LH2
holder when using four
contact blocks and
transformer
HW-LH3
1904032203
www.IDEC.com
704
ø22mm - TW Series
Switches & Pilot Devices
Pilot Lights (Assembled)
Assembled Pilot Lights
(B) (99) (D) – R – (24V)
A
P
(Q)
W
1
Function
Lamp Voltage
(Full Voltage Units Only)
P: Pilot Light
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC
240V: 240V AC
Bezel Shape
Blank: Octagonal (round lenses)
Q: Square
Series Designation
Lens Color Code
W: TW Series
A: Amber
G: Green
R: Red
Lens Shape
S: Blue
W: White
Y: Yellow
1: Flat
2: Dome
Lens Type
Lamp
Blank: Standard (ribbed)
B: Engravable (smooth with insert included)
D: LED
Illumination Circuit
99: Full Voltage (lamp determines voltage)
126: 120V AC Step Down Transformer
246: 240V AC Step Down Transformer
486: 480V AC Step Down Transformer
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. All transformers step down to 6V.
1904032203
800-262-IDEC (4332) • USA & Canada
705
ø22mm - TW Series
Switches & Pilot Devices
Pilot Lights (Assembled) continued
Assembled Pilot Lights
kLens Color Codes
Style
Type
Voltage
Part Number
Color
Amber
Green
Red
Code
120VAC
240VAC
480VAC
APW1126D-k
APW1246D-k
APW1486D-k
A
G
R
Transformer
Round Flat
Full Voltage
Transformer
Full Voltage
Transformer
Full Voltage
—
APW199D-k-l
Blue
S
White
Yellow
W
Y
120VAC
240VAC
480VAC
APW2126D-k
APW2246D-k
APW2486D-k
Dome
lFull Voltage Codes
—
APW299D-k-l
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Code
6V
120VAC
240VAC
480VAC
APQW1B126D-k
APQW1B246D-k
APQW1B486D-k
12V
Square Flat
24V
120V
240V
—
APQW1B99D-k-l
240V AC
1. In place of k, specify the Lens Color Code from table below.
2. In place of l, specify the Full Voltage Code from table below.
3. For accessories, see page 728.
4. For dimensions, see page 730.
5. For sub-assembly part numbers, see next page.
6. Yellow pilot light comes with white LED.
1904032203
www.IDEC.com
706
ø22mm - TW Series
Switches & Pilot Devices
Pilot Lights (Sub-Assembled)
Transformer
+
Operator
+
Lamp
+
Lens
=
Complete Part
* Transformer not required for full voltage units.
Operators
Lamps
kLED/Lens Color Codes
Style
Part Number
Style
Voltage
Part Number
LSTD-6k
Color
Amber
Green
Red
Code
Round Dome/Flat
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
A
G
R
LED
LSTD-1k
LSTD-2k
APW-199
LSTD-H2k
LSTD-M4k
Blue
S
240V AC
White
Yellow
W
Y
1. In place of k, specify the LED color code.
2. The LED contains a current-limiting resistor and a
protection diode.
Square
If clear lens is desired, use
white marking lens and
remove engraving insert
3. Yellow LED not available. Use white LED.
UPQW-199
Transformers
Style
Description
120V AC
Part Number
TW-F126B
Same operator is used for full voltage as for
transformer completed units.
240V AC
480V AC
TW-F246B
TW-F486B
Finger-Safe
Lenses
Part Number
Style
Standard
Engravable
Dome
All Transformers step down to 6V (use 6V LED).
—
APW2LU-k
Round Flat
Square Flat
APW1LU-k
APW1BLU-k
—
APQW1BLU-k
1. In place of k, specify the Lens Color Code from table.
2. Standard lenses have a ribbed lens to enhance light
dispersion. Marking lenses are smooth and include an
engravable insert.
1904032203
800-262-IDEC (4332) • USA & Canada
707
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Assembled)
Assembled Illuminated Pushbuttons
A
L
(F)
W
2
(B) 99 11 (D) – R – (24V)
Function
Lamp Voltage
(Full Voltage Units Only)
L:Momentary Action
OL:Maintained Action
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC
240V: 240V AC
Bezel Shape
Blank: Octagonal (round lenses)
F: Full Shroud (round lenses)
Q: Square
Lens Code
A: Amber
G: Green
R: Red
Series Designation
W: TW series
S: Blue
W: White
Y: Yellow
Lens Shape/Size
2: Standard Extended (round or square)
3: 29mm Mushroom
4: 40mm Mushroom
Lamp Type
D: LED Lamp
Lens Type
Contact Arrangement
Blank: Standard (ribbed)
10: 1NO
20: 2NO
01: 1NC
02: 2NC
B: Engravable (smooth with insert)
11: 1NO-1NC
22: 2NO-2NC
Illumination Circuit
99: Full Voltage (lamp determines voltage)
126: 120V AC Step Down Transformer
246: 240V AC Step Down Transformer
486: 480V AC Step Down Transformer
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. Transformers step down to 6V.
1904032203
www.IDEC.com
708
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Assembled)
Illuminated Pushbuttons
kLED/Lens Color Codes
Part Number
Contacts
Color
Amber
Green
Red
Code
Style
Momentary
Maintained
A
G
R
Extended Lens
1NO-1NC
2NO
ALW2 m11D-k
ALW2 m20D-k
ALW2 m02D-k
AOLW2 m11D-k
AOLW2 m20D-k
AOLW2 m02D-k
Transformer
Full Voltage
Transformer
Full Voltage
Transformer
Full Voltage
Transformer
Full Voltage
Transformer
Full Voltage
2NC
Blue
S
White
Yellow
W
Y
1NO-1NC
2NO
2NC
ALW29911D-k-l
ALW29920D-k-l
ALW29902D-k-l
AOLW29911D-k-l
AOLW29920D-k-l
AOLW29902D-k-l
1. Mushroom lenses not
available in yellow.
2. Yellow pushbutton comes
with white LED.
1NO-1NC
2NO
2NC
ALFW2 m11D-k
ALFW2 m20D-k
ALFW2 m02D-k
AOLFW2 m11D-k
AOLFW2 m20D-k
AOLFW2 m02D-k
Extended Lens with Full Shroud
lFull Voltage Codes
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Code
6V
12V
1NO-1NC
2NO
2NC
ALFW29911D-k-l
ALFW29920D-k-l
ALFW29902D-k-l
AOLFW29911D-k-l
AOLFW29920D-k-l
AOLFW29902D-k-l
24V
120V
240V
240V AC
ø29mm Mushroom Button
1NO-1NC
2NO
2NC
ALW3 m11D-k
ALW3 m20D-k
ALW3 m02D-k
AOLW3 m11D-k
AOLW3 m20D-k
AOLW3 m02D-k
mTransformer Voltage Codes
Voltage
120VAC
240VAC
480VAC
Code
126
1NO-1NC
2NO
2NC
ALW39911D-k-l
ALW39920D-k-l
ALW39902D-k-l
AOLW39911D-k-l
AOLW39920D-k-l
AOLW39902D-k-l
246
486
Transformers step down to 6V
(use 6V LED).
ø40mm Mushroom Button
1NO-1NC
2NO
2NC
ALW4 m11D-k
ALW4 m20D-k
ALW4 m02D-k
AOLW4 m11D-k
AOLW4 m20D-k
AOLW4 m02D-k
1NO-1NC
2NO
2NC
ALW49911D-k-l
ALW49920D-k-l
ALW49902D-k-l
AOLW49911D-k-l
AOLW49920D-k-l
AOLW49902D-k-l
Square Extended
1NO-1NC
2NO
2NC
ALQW2B m11D-k
ALQW2B m20D-k
ALQW2B m02D-k
AOLQW2B m11D-k
AOLQW2B m20D-k
AOLQW2B m02D-k
1NO-1NC
2NO
2NC
ALQW2B9911D-k-l
ALQW2B9920D-k-l
ALQW2B9902D-k-l
AOLQW2B9911D-k-l
AOLQW2B9920D-k-l
AOLQW2B9902D-k-l
1. In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow.
2. In place of l, specify the Full Voltage Code (lamp voltage) (see table).
3. In place of m, specify the Transformer Voltage Code (see table).
4. For sub-assembly part numbers, see next page.
5. For accessories, see page 728.
6. For dimensions, see page 730.
7. Light is independent of switch position.
8. Yellow pushbutton comes with white LED.
1904032203
800-262-IDEC (4332) • USA & Canada
709
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Sub-Assembled)
Transformer/
+
Contacts
+
Lamp Holder
+
Operator
+
Lamp
+
Lens
=
Complete Part
Adaptor*
*Not applicable for full voltage units
Operators
Lamps
Part Number
Style
Voltage
Part Number
LSTD-6k
Style
Momentary
Maintained
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
LED
LSTD-1k
LSTD-2k
Extended
ALW-0600
AOLW-0600
LSTD-H2k
LSTD-M4k
240V AC
1. In place of k, specify the LED color code.
2. The LED contains a current-limiting resistor and a
protection diode.
Extended with
Full Shroud
ALFW-0600
ALW3-0600
AOLFW-0600
AOLW3-0600
Lamp Circuit Components
Style
Application
Part Number
ø29mm/ø40mm
Mushroom
Long Lamp Holder
Used with Full-size
Transformer and two
contact blocks
TW-LH2
Square/Extended
ALQW-2B0600 AOLQW-2B0600
Lead Holder
Used with TW-LH2
holder when using four
contact blocks and
transformer
Lenses
HW-LH3
Part Number
Style
Standard
Engravable
Round Extended
ALW2LU-k
ALW2BLU-k
ALW3BLU-k
ALW4BLU-k
ALQW2BLU-k
kLED/Lens Color Codes
Color
Amber
Green
Red
Code
Color
Code
A
G
R
Blue
S
White
W
Y
ø 29mm
Mushroom Head*
ALW3LU-k
ALW4LU-k
—
Yellow
Yellow LED not available. Use white LED.
ø 40mm
Mushroom Head*
Square Extended
1. In place of k, specify the lens color code from table on the bottom right.
2. *Mushroom lens not available in yellow.
3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an
engravable insert.
1904032203
www.IDEC.com
710
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Pushbuttons (Sub-Assembled) continued
Contact Blocks
Transformers/Full Voltage Modules
Style
Contacts 1NO
1NC
Style
Description
Part Number
Full Size Transformer
Finger-
Safe
Spring-Up
Terminal
HW-U10-F
HW-U01-F
120V AC
240V AC
TW-F126B
HW-U10R-F HW-U01R-F
(early make) (late break)
TW-F246B
TW-F486B
Finger-Safe
Dummy
Block
480V AC
HW-DB
For use
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
Dummy Block with
Full Voltage Adaptor
with odd
number of
contacts.
Finger-Safe
HW-DA1FBN
TW-DA1FB
For use
with even
number of
contacts.
Full Voltage Adaptor
Finger-Safe
All Transformers step down to 6V (use 6V LED).
1904032203
800-262-IDEC (4332) • USA & Canada
711
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled)
Assembled Selector Switches
A
S
W
3
(1) (L) 20 – 304
Function
Circuit Number
S: Selector Switch
(Standard circuits shown on following
pages and 720.)
Series Designation
Contact Arrangement Code
W: TW Series
10: 1NO
20: 2NO
40: 4NO
01: 1NC
02: 2NC
04: 4NC
Number of Positions
2: 2-Position
3: 3-Position
4: 4-Position
5: 5-Position
11: 1NO-1NC 22: 2NO-2NC
Operator Style Code
Blank:
Knob Operator
L: Lever Operator
K: Key Operator
Spring Return Action
Blank: Maintained
1: Spring return from Right (2 or 3 position)
2: Spring return from Left (2 or 3 position)
3: 2-Way spring return from Left and Right
(3 position only)
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. Custom contact configurations available.
3. Custom key removable codes available.
4. Portions of part number inside ( ) are optional.
1904032203
www.IDEC.com
712
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled) continued
2-Position Selector Switches
Style
Part Number
Operator
Position
Spring Return
from Right
Spring Return
from Left
Maintained
L
R
L
L
R
L
R
R
Knob
Lever
Key
ASW210
ASW2L10
ASW2K10
ASW2110
ASW21L10
ASW21K10
ASW2210
ASW22L10
ASW22K10
1
2
O
O
X
O
1NO
1NC
Knob
Lever
Key
ASW201-116
ASW2L01-116
ASW2K01-116
ASW2101-116
ASW21L01-116
ASW21K01-116
ASW2201-116
ASW22L01-116
ASW22K01-116
1
2
X
O
O
O
Knob
Lever
Key
ASW211
ASW2L11
ASW2K11
ASW2111
ASW21L11
ASW21K11
ASW2211
ASW22L11
ASW22K11
1NO
1NC
1
2
X
O
O
X
Knob
Lever
Key
ASW220
ASW2L20
ASW2K20
ASW2120
ASW21L20
ASW21K20
ASW2220
ASW22L20
ASW22K20
1
2
O
O
X
X
2NO
2NC
Knob
Lever
Key
ASW202-104
ASW2L02-104
ASW2K02-104
ASW2102-104
ASW21L02-104
ASW21K02-104
ASW2202-104
ASW22L02-104
ASW22K02-104
1
2
X
X
O
O
1
2
3
4
O
X
O
X
X
O
X
O
Knob
Lever
Key
ASW222
ASW2L22
ASW2K22
ASW2122
ASW21L22
ASW21K22
ASW2222
ASW22L22
ASW22K22
2NO
2NC
1
2
3
4
O
O
X
X
X
X
O
O
Knob
Lever
Key
ASW222-111
ASW2L22-111
ASW2K22-111
ASW2122-111
ASW21L22-111
ASW21K22-111
ASW2222-111
ASW22L22-111
ASW22K22-111
2NO
2NC
1904032203
800-262-IDEC (4332) • USA & Canada
713
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Assembled) continued
Part Number
3-Position Selector Switches
Style
Operator Position
C
Maintained
Spring Return from Right
Spring Return from Left
Spring Return Two-Way
C
C
C
C
L
R
L
L
L
L
R
R
R
R
Knob
Lever
Key
ASW320
ASW3L20
ASW3K20
ASW3120
ASW31L20
ASW31K20
ASW3220
ASW32L20
ASW32K20
ASW3320
ASW33L20
ASW33K20
1
2
X
O
O
O
O
X
2NO
2NC
Knob
Lever
Key
ASW302
ASW3L02
ASW3K02
ASW3102
ASW31L02
ASW31K02
ASW3202
ASW32L02
ASW32K02
ASW3302
ASW33L02
ASW33K02
X
X
1
2
O
X
X
O
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
Knob
Lever
Key
ASW322
ASW3L22
ASW3K22
ASW3122
ASW31L22
ASW31K22
ASW3222
ASW32L22
ASW32K22
ASW3322
ASW33L22
ASW33K22
2NO
2NC
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
Knob
Lever
Key
ASW322-309
ASW3L22-309
ASW3K22-309
ASW3122-309
ASW31L22-309
ASW31K22-309
ASW3222-309
ASW32L22-309
ASW32K22-309
ASW3322-309
ASW33L22-309
ASW33K22-309
2NO
2NC
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
Knob
Lever
Key
ASW322-310
ASW3L22-310
ASW3K22-310
ASW3122-310
ASW31L22-310
ASW31K22-310
ASW3222-310
ASW32L22-310
ASW32K22-310
ASW3322-310
ASW33L22-310
ASW33K22-310
2NO
2NC
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Knob
Lever
Key
ASW340
ASW3L40
ASW3K40
ASW3140
ASW31L40
ASW31K40
ASW3240
ASW32L40
ASW32K40
ASW3340
ASW33L40
ASW33K40
4NO
4NC
X
X
X
X
1
2
3
4
O
X
O
X
X
O
X
O
Knob
Lever
Key
ASW304
ASW3L04
ASW3K04
ASW3104
ASW31L04
ASW31K04
ASW3204
ASW32L04
ASW32K04
ASW3304
ASW33L04
ASW33K04
1. The truth table indicates the operating position of contact block when the operator is switched to that position.
X = On (closed contacts)
O = Off (open contacts)
X
X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions.
2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately.
3. Every key selector switch uses an identical key. The key is removable in any maintained position.
4. Custom contact configurations are available, see page 720.
4-Position Selector Switch
5-Position Selector Switch
Style
Maintained
Part Number
2
Style
Maintained
Part Number
3
Operator Position
Operator Position
3
2
2
4
1
3
4
1
2
4
5
1
3
1
5
4
1
2
3
4
X
O
O
O
O
X
O
O
O
O
X
O
O
O
O
X
1
2
3
4
X
O
O
O
O
X
O
O
O
O
O
O
O
O
X
O
O
O
O
X
2NO
2NC
Knob
Lever
ASW422-411
ASW4L22-411
2NO
2NC
Knob
Lever
ASW522-501
ASW5L22-501
1904032203
www.IDEC.com
714
ø22mm - TW Series
Switches & Pilot Devices
Non-Illuminated Selector Switches (Sub-Assembled)
Contact Blocks
+
Operator
+
Knob or Lever*
+
Color Insert*
=
Complete Part†
1. *Not needed with key type switches.
2. †Knob type shown.
Operators
Handles and Inserts
Style
Positions
Description
Part Number
Style
Part Number
Maintained
ASW200
ASW2100
ASW2200
2
Spring return from right
Spring return from left
Knob
Lever
ASWHHY-j
Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3
ASW300-1
ASW300-2
ASW300-3
Knob/Lever
Spring return from right, Cam 1
Spring return from right, Cam 2
ASW3100-1
ASW3100-2
3
ASWHHL-j
TW-HC1-j
Spring return from left, Cam 1
Spring return from left, Cam 2
ASW3200-1
ASW3200-2
Spring return from left/right, Cam 1
Spring return from left/right, Cam 2
ASW3300-1
ASW3300-2
Maintained, Standard Cam
Maintained, Cam 1
ASW400
ASW400-1
4
5
Color
Insert
Maintained, Standard cam
Maintained, Cam 1
ASW500
ASW500-1
Maintained
ASW2K00
ASW21K00
ASW22K00
2
Spring return from right
Spring return from left
Contact Blocks
Key
Style
Contacts 1NO
1NC
Maintained, Cam 1
Maintained, Cam 2
Maintained, Cam 3
ASW3K00-1
ASW3K00-2
ASW3K00-3
HW-U10-F
HW-U01-F
Finger-
Safe
Spring return from right, Cam 1
Spring return from right, Cam 2
ASW31K00-1
ASW31K00-2
Spring-Up
Terminal
3
HW-U10R-F HW-U01R-F
(early make) (late break)
Spring return from left, Cam 1
Spring return from left, Cam 2
ASW32K00-1
ASW32K00-2
Spring return from left/right, Cam 1
Spring return from left/right, Cam 2
ASW33K00-1
ASW33K00-2
Dummy
Block
HW-DB
1. Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position.
2. Locking rings are included with all operators. Order knobs, levers, and color inserts separately.
3. Different cams produce different contact actions. For details, see page 720.
4. Key switch operator supplied with black sleeve.
1. Push rod color code:
Green = NO contact block
Red = NC contact block.
2. Dummy blocks (no contacts) are used with an odd
number of contact blocks.
Replacement Parts
Key Switch Black Sleeve
jHandle/Insert Color Codes
AKW2B-B
Color
Black*
Blue
Code
B
S
Green
Red
G
R
Yellow
White†
Y
W
*Color inserts not available in black.
†Knob and lever not available in white.
1904032203
800-262-IDEC (4332) • USA & Canada
715
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches (Assembled)
Assembled Illuminated Selector Switches
A
SL
W
2
(2) 99 11 (D) – (103) – R – (24V)
Function
Lamp Voltage
(Full Voltage Units Only)
SL:Illuminated Selector Switch
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC
240V: 240V AC
Series Designation
W: TW series
Number of Positions
Lens Color Code
2: 2-Position
3: 3-Position
A: Amber
G: Green
R: Red
Spring Return Action
S: Blue
W: White
Y: Yellow
Blank: Maintained
1: Spring return from Right
2: Spring return from Left
3: Two-Way spring return from Left and Right
Contact Circuit Number
Illumination Circuit
Standard circuits are listed on the
following pages and 720.
99: Full Voltage (lamp determines voltage)
126: 120V AC Step Down Transformer
246: 240V AC Step Down Transformer
486: 480V AC Step Down Transformer
Lamp Type
D: LED Lamp
Contact Arrangement
10: 1NO
20: 2NO
01: 1NC
02: 2NC
40: 4NO
11: 1NO-1NC
04: 4NC
22: 2NO-2NC
1. Use only when interpreting part numbers. Do not use for developing part numbers.
2. All transformers step down to 6V (use 6V lamp).
1904032203
www.IDEC.com
716
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches(Assembled) continued
Illuminated 2-Position Selector Switches
jTransformer Voltage Codes
Style
Part Number
Voltage
120VAC
240VAC
480VAC
Code
126
Operator
Position
Maintained
Spring Return from Right Spring Return from Left
Lamp
Circuit Type
246
L
L
R
L
L
R
R
R
486
Transformers step down to 6V
(use 6V LED).
1NO
1NC
1
2
O
X
X
O
Transformer
Full Voltage
ASLW2 j11D-k
ASLW29911D-k-l
ASLW21 j11D-k
ASLW219911D-k-l
ASLW22 j11D-k
ASLW229911D-k-l
1
2
O
O
X
X
Transformer
Full Voltage
ASLW2 j20D-k
ASLW29920D-k-l
ASLW21 j20D-k
ASLW219920D-k-l
ASLW22 j20D-k
ASLW229920D-k-l
2NO
2NC
kLED/Lens Color Codes
1
2
X
X
O
O
Transformer
Full Voltage
ASLW2 j02D-104-k
ASLW29902D-104-k-l
ASLW21 j02D-104-k
ASLW219902D-104-k-l ASLW229902D-104-k-l
ASLW22 j02D-104-k
Color
Amber
Green
Red
Code
A
G
R
1
2
3
4
O
X
O
X
X
O
X
O
2NO
2NC
Transformer
Full Voltage
ASLW2 j22D-k
ASLW29922D-k-l
ASLW21 j22D-k
ASLW219922D-k-l
ASLW22 j22D-k
ASLW229922D-k-l
Blue
S
White
Yellow
W
Y
Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right
Style
Part Number
Operator Position
C
Maintained
Spring Return From Right
Spring Return from Left
Spring Return Two-Way
Lamp
Circuit Type
C
C
C
C
L
R
L
L
L
L
R
R
R
R
1
2
X
O
O
O
O
X
Transformer
Full Voltage
ASLW3 j20D-k
ASLW39920D-k-l
ASLW31 j20D-k
ASLW319920D-k-l
ASLW32 j20D-k
ASLW329920D-k-l
ASLW33 j20D-k
ASLW339920D-k-l
2NO
2NC
1
2
O
X
X
X
X
O
Transformer
Full Voltage
ASLW3 j02D-k
ASLW39902D-k-l
ASLW31 j02D-k
ASLW319902D-k-l
ASLW32 j02D-k
ASLW329902D-k-l
ASLW33 j02D-k
ASLW339902D-k-l
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
2NO
2NC
Transformer
Full Voltage
ASLW3 j22D-k
ASLW39922D-k-l
ASLW31 j22D-k
ASLW319922D-k-l
ASLW32 j22D-k
ASLW329922D-k-l
ASLW33 j22D-k
ASLW339922D-k-l
1
2
3
4
X
X
O
O
O
X
X
O
X
O
O
X
2NO
2NC
Transformer
Full Voltage
ASLW3 j22D-309-k
ASLW39922D-309-k-l
ASLW31 j22D-309-k
ASLW319922D-309-k-l
ASLW32 j22D-309-k
ASLW329922D-309-k-l
ASLW33 j22D-309-k
ASLW339922D-309-k-l
1
2
3
4
O
O
O
O
X
O
X
O
O
X
O
X
2NO
2NC
Transformer
Full Voltage
ASLW3 j22D-310-k
ASLW39922D-310-k-l
ASLW31 j22D-310-k
ASLW319922D-310-k-l
ASLW32 j22D-310- k
ASLW329922D-310- k-l
ASLW33 j22D-310-k
ASLW339922D-310-k-l
1
2
3
4
X
O
X
O
O
O
O
O
O
X
O
X
Transformer
Full Voltage
ASLW3 j40D-k
ASLW39940D-k-l
ASLW31 j40D-k
ASLW319940D-k-l
ASLW32 j40D-k
ASLW329940D-k-l
ASLW33 j40D-k
ASLW339940D-k-l
4NO
4NC
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Transformer
Full Voltage
ASLW3 j04D-k
ASLW39904D-k-l
ASLW31 j04D-k
ASLW319904D-k-l
ASLW32 j04D-k
ASLW329904D-k-l
ASLW33 j04D-k
ASLW339904D-k-l
1. In place of j, specify the Transformer Voltage Code.
2. In place of k, specify the Lens/LED Color Code.
3. In place of l, specify the Full Voltage Code.
4. For custom contact configurations, see page 720.
5. Light is independent of switch position.
lFull Voltage Codes
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Code
6V
6. Yellow selector switch comes with white LED.
12V
24V
120V
240V
240V AC
1904032203
800-262-IDEC (4332) • USA & Canada
717
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches (Sub-Assembled)
Transformer*
+
Contact Block
+
Operator
+
Lamp/Lead Holder†
+
LED
+
Lens
=
Complete Part
*Full voltage units use a full voltage adaptor
TW-DA1FB (even number of blocks)
OR
HW-DA1FBN (odd number of blocks) instead of a transformer.
†Lamp holder is not included with operators, order separately.
Operators
Lamps
Style
Positions
Description
Part Number
Style
Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
Part Number
LSTD-6k
LSTD-1k
LSTD-2k
LSTD-H2k
LSTD-M4k
Maintained
ASLW200
LED
Spring return from right
Spring return from left
ASLW2100
ASLW2200
2
240V AC
ASLW300-1
ASLW300-2
ASLW300-3
ASLW3100-1
ASLW3100-2
ASLW3200-1
ASLW3200-2
ASLW3300-1
ASLW3300-2
Maintained, cam 1
Maintained, cam 2
Maintained, cam 3
1. In place of k, specify the LED color code.
2. The LED contains a current-limiting resistor and a
protection diode.
Spring return from right, cam 1
Spring return from right, cam 2
3
kLED/Lens Color Codes
Spring return from left, cam 1
Spring return from left, cam 2
Color
Amber
Green
Red
Code
A
G
R
Spring return from left/right, cam 1
Spring return from left/right, cam 2
Different cams produce different contact action. For details, see Contact Arrangements
on page 720.
Blue
S
White
Yellow
W
Y
Lenses (Knobs)
Yellow LED not available. Use
white LED
Style
Part Number
Knob
ASLWLU-k
In place of k, specify the lens color code from table.
1904032203
www.IDEC.com
718
ø22mm - TW Series
Switches & Pilot Devices
Illuminated Selector Switches (Sub-Assembled) continued
Contact Blocks
Transformers/Full Voltage Modules
Style
Contacts 1NO
1NC
Style
Description
Part Number
Full Size Transformer
Finger-
Safe
Spring-Up
Terminal
HW-U10-F
HW-U01-F
120V AC
240V AC
TW-F126B
HW-U10R-F HW-U01R-F
(early make) (late break)
TW-F246B
TW-F486B
Finger-Safe
Dummy
Block
480V AC
HW-DB
For use
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.
2. Use of early and late break contacts creates a make before break function
Dummy Block with
Full Voltage Adaptor
with odd
number of
contacts.
Finger-Safe
HW-DA1FBN
TW-DA1FB
For use
Lamp Circuit Components
with even
number of
contacts.
Full Voltage Adaptor
Finger-Safe
Style
Application
Part Number
Short Lamp Holder
All Transformers step down to 6V (use 6V lamp).
Used with full voltage
adaptor and one contact
block
TW-LH1
Long Lamp Holder
Used with Full-size
Transformer and two
contact blocks
TW-LH2
HW-LH3
Lead Holder
Used with TW-LH2
holder when using four
contact blocks and full
size transformer
1904032203
800-262-IDEC (4332) • USA & Canada
719
ø22mm - TW Series
Switches & Pilot Devices
R
Contact Arrangement Charts
L
4
2
How to Read Contact Arrangement Charts
3
To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right
Contact Arrangement
Type and quantity of switch
contacts
1
Contact Block
Mounting Position
Position or mounting contact
blocks on operator.
Circuit Number
* N/D = No
designation required
Operator Position
Truth table indicates the
Contact Block
Part Number
operating position of contact
block when operator is
switched to that position
(X - closed, O - open).
Part number to use when
ordering sub-assembly contact
blocks, as required for use
with corresponding mounting
position
Contact Arrangement Chart: 2-Position Selector Switches
Style
Operator Part Number
Spring Ret.
Operator
Position
Spring Ret.
from Lt.
Maintained
Mounting
Position
Contact Block
Part Number
from Rt.
Description
Circuit
Contact
L
R
Number
L
L
R
L
R
R
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
O
O
X
O
O
X
X
O
O
X
X
O
O
O
X
X
O
X
O
X
O
O
X
X
X
O
O
O
X
O
O
X
X
O
O
X
X
X
O
O
X
O
X
O
X
X
O
O
HW-U10-F
HW-DB
1NO
1NC
N/D
116
N/D
103
600
601
N/D
104
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
HW-U01-F
HW-DB
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
HW-U10-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U10R-F
HW-U01R-F
HW-U01R-F
HW-U10R-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
1NO
1NC
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
1NO-EM
1NC-LB
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
2NO
2NC
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
N/D
111
2NO
2NC
Knob/Lever
Key
Illuminated Knob
ASW200
ASW2K00
ASLW200
ASW2100
ASW21K00
ASLW2100
ASW2200
ASW22K00
ASLW2200
1. NO-EM, NC-LB = Early Make, Late Break.
N/D = No circuit number designation required in assembled selector switch part number.
2. X = On (closed contacts) O = Off (Open contacts)
1904032203
www.IDEC.com
720
ø22mm - TW Series
Switches & Pilot Devices
Contact Arrangement Chart: 3-Position Selector Switches
Style
Operator Part Number
Spring Return Spring Return
Operator Position
Maintained
Two-Way
Mounting
Position
Contact Block
Part Number
from Right
from Left
Description
Circuit
Contact
C
C
C
C
C
L
R
Number
L
L
L
L
R
R
R
R
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
X
X
0
0
X
X
0
0
X
X
0
0
0
0
0
X
X
X
X
0
O
X
X
X
O
O
X
0
HW-U10-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
202
203
302
303
N/D
301
304
N/D
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
O
X
X
0
1NO
1NC
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
O
X
O
X
O
0
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
X
X
X
O
O
X
O
2NO
2NC
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
X
0
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
X
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
X
0
0
X
0
0
0
0
X
X
X
X
X
X
0
O
0
O
0
0
0
0
X
X
X
0
X
0
0
X
0
X
0
X
X
0
X
0
X
0
0
X
X
0
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
HW-U01-F
HW-U10-F
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
N/D
210
308
309
310
X
X
X
X
X
0
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
2NO
2NC
X
O
X
0
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
O
X
O
X
O
X
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
1. Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open
and closed contacts in the various operator positions.
2. N/D = No circuit number designation required in assembled part number.
3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions.
1904032203
800-262-IDEC (4332) • USA & Canada
721
ø22mm - TW Series
Switches & Pilot Devices
Contact Arrangement Chart: 3-Position Selector Switches
Style
Operator Part Number
Spring Return Spring Return
Operator Position
Maintained
Two-Way
Mounting
Position
Contact Block
Part Number
from Right
from Left
Description
Circuit
Contact
C
C
C
C
C
L
R
Number
L
L
L
L
R
R
R
R
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
X
0
X
0
X
0
X
0
0
X
0
X
0
X
0
X
0
0
0
0
0
0
0
0
X
X
X
X
X
X
X
X
0
X
0
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U10-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
HW-U01-F
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
N/D
305
N/D
314
X
X
X
X
X
X
0
4NO
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
Knob/Lever
Key
Illuminated Knob
ASW300-1
ASW3K00-1
ASLW300-1
ASW3100-1
ASW31K00-1
ASLW3100-1
ASW3200-1
ASW32K00-1
ASLW3200-1
ASW3300-1
ASW33K00-1
ASLW3300-1
X
O
O
0
4NC
Knob/Lever
Key
Illuminated Knob
ASW300-2
ASW3K00-2
ASLW300-2
ASW3100-2
ASW31K00-2
ASLW3100-2
ASW3200-2
ASW32K00-2
ASLW3200-2
ASW3300-2
ASW33K00-2
ASLW3300-2
O
0
1. Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open
and closed contacts in the various operator positions.
2. N/D = No circuit number designation required in assembled part number.
3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions.
1904032203
www.IDEC.com
722
ø22mm - TW Series
Switches & Pilot Devices
Custom Selector Switch Building Guide
To build a custom selector switch, follow these steps.
Mounting Positions
R
4
L
Step 1
2
How many positions of the switch are needed?
# of positions
(2, 3, 4, 5)
3
1
Step 2
How many contacts should there be?
# of isolated contacts
(maximum 6)
Step 3
Fill in the Truth Table
(X = closed, 0 = open)
Knob Position
1
2
3
4
5
1
2
3
4
5
6
Step 4
If building a 2 position selector, skip this step. (2 position selectors have only one cam)
If building a 3, 4, or 5 position selector, determine appropriate cam as follows:
• Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page).
• Repeat for all rows. The user must find one operator that contains all rows from above table.
• Record the operator cam version.
Step 5
Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right
side of operator as viewed from the front of the panel.
Step 6
Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 712 or 716. In place of the
“Circuit Number” indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where “3” is the cam number, and contact arrangement “OELCXX”
calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 pos-
sible mounting locations.
Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance.
1. For Operator Truth Tables, see next page.
1904032203
800-262-IDEC (4332) • USA & Canada
723
ø22mm - TW Series
Switches & Pilot Devices
OperatorTruthTables
Use the following tables to build custom selector switches.
2 Position Selector Switches
4 Position Selector Switches
Operator
Position
Operator Position
Mounting
Position
Mounting
Position
Contact
Contact
1
X
O
O
X
X
O
O
X
2
O
X
X
O
O
X
X
O
3
O
O
X
X
O
O
X
X
4
O
O
X
X
O
O
X
X
Left
Right
L
R
L
HW-U10-F
(NO)
L
R
L
O
O
X
X
O
O
X
X
X
X
O
O
X
X
O
O
HW-U10-F
(NO)
HW-U01-F
(NC)
HW-U01-F
(NC)
R
L
ASW200
ASLW200
ASW2K00
ASW400
R
L
HW-U10R-F
(NO-EM)
HW-U10R-F
(NO-EM)
R
L
R
L
HW-U01R-F
(NC-LB)
HW-U01R-F
(NC-LB)
R
R
Operator Position
Mounting
Position
3 Position Selector Switches
Contact
1
2
O
O
O
X
X
O
X
X
3
O
O
X
O
O
X
X
X
4
Operator Position
Mounting
Position
Contact
L
R
L
X
O
O
O
X
X
O
X
O
X
O
O
X
X
X
O
HW-U10-F
(NO)
Left Center Right
L
R
L
X
O
O
X
X
O
O
X
O
O
X
X
O
O
X
X
O
X
X
O
O
X
X
O
HW-U10-F
(NO)
HW-U01-F
(NC)
R
L
ASW400-1
HW-U01-F
(NC)
HW-U10R-F
(NO-EM)
ASW300-1
ASW3K00-1
ASLW300-1
R
L
R
L
HW-U10R-F
(NO-EM)
HW-U01R-F
(NC-LB)
R
L
R
HW-U01R-F
(NC-LB)
R
5 Position Selector Switches
Operator Position
Mounting
Position
Contact
Operator Position
Mounting
Position
1
X
O
O
O
X
O
O
X
2
O
X
O
O
O
X
X
O
3
O
O
X
O
O
O
X
X
4
O
O
X
X
O
O
X
X
5
O
O
X
X
O
O
X
X
Contact
Left Center Right
L
R
L
HW-U10-F
(NO)
L
R
L
X
O
O
X
X
O
O
X
O
O
X
X
O
O
X
X
X
X
O
O
X
X
O
O
HW-U10-F
(NO)
HW-U01-F
(NC)
HW-U01-F
(NC)
R
L
ASW500
ASW300-2
ASW3K00-2
ASLW300-2
R
L
HW-U10R-F
(NO-EM)
HW-U10R-F
(NO-EM)
R
L
R
L
HW-U01R-F
(NC-LB)
HW-U01R-F
(NC-LB)
R
R
Operator Position
Mounting
Position
Contact
Operator Position
Mounting
Position
1
X
O
O
O
2
O
O
O
X
X
O
X
X
3
O
O
O
O
X
X
X
X
4
O
O
X
O
O
X
X
X
5
O
X
O
O
X
X
X
O
Contact
Left Center Right
L
R
L
HW-U10-F
(NO)
L
R
L
X
O
O
O
X
X
O
X
O
O
X
X
O
O
X
X
O
X
O
O
X
X
X
O
HW-U10-F
(NO)
HW-U01-F
(NC)
HW-U01-F
(NC)
R
L
ASW500-1
ASW300-3
ASW3K00-3
ASLW300-3
R
L
X
HW-U10R-F
(NO-EM)
HW-U10R-F
(NO-EM)
R
L
X
R
L
O
HW-U01R-F
(NC-LB)
HW-U01R-F
(NC-LB)
X
R
R
1904032203
www.IDEC.com
724
ø22mm - TW Series
Switches & Pilot Devices
Nameplates —TW Series
Faceplates
NWAL
NWAQL
NWAS
EMERGENCY STOP
1.13" (29mm)
1.76" (45mm)
1.13" (29mm)
Part Number
NWAS-OB
NWAS-j
Nameplate
(blank)
NWAL-OB (black)
NWAL-OR (red)
NWAQL-OB (black)
NWAQL-OR (red)
NWAR-O
NWAR-27†
Nameplate
(engraved)
NWAL-j
NWAQL-j
1. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by “ “.
2. Standard engravings are available at no charge.
3
NWAR-27 comes marked “Emergency Stop” as shown in drawing.
Standard Legend Codes
Pushbuttons
Pushbuttons/Selector Switches
Selector Switches
Legend
Legend
AUTO
CLOSE
DOWN
EMERG.STOP
FAST
FORWARD
HAND
HIGH
IN
INCH
JOG
LOW
LOWER
OFF
ON
Code
Legend
Code
Legend
Code
Legend
Code
Code
AUTO-MAN-OFF
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
101 OPEN
102 OUT
103 RAISE
104 RESET
105 REVERSE
106 RUN
107 SLOW
108 START
109 STOP
110 STOP
111 TEST
112 UP
113 I (Int’l On)
114 O (Int’l Off)
115 EMO
116 AUTO-MAN
117 CLOSE-OPEN
118 DOWN-UP
119 FAST-SLOW
120 FOR-REV
121 HAND-AUTO
122 HIGH-LOW
123 JOG-RUN
124 LEFT-RIGHT
125 LOWER-RAISE
126 MAN-AUTO
127 OFF-ON
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
AUTO-OFF-MAN
CLOSE-OFF-OPEN
DOWN-OFF-SLOW
FAST-OFF-SLOW
FOR-OFF-REV
LEFT-OFF-RIGHT
LOWER-OFF-RAISE
OFF-MAN-AUTO
OFF-SLOW-FAST
OFF-1-2
OPEN-OFF-CLOSE
SLOW-OFF-FAST
SUMMER-OFF-WINTER
UP-OFF-DOWN
1-OFF-2
REV-FOR
RUN-JOG
216
217
218
219
220
221
222
223
RUN-SAFE
SAFE-RUN
SLOW-FAST
START-STOP
STOP-START
UP-DOWN
150 ON-OFF
151 OPEN-CLOSE
152 RAISE-LOWER
HAND-OFF-AUTO
1. To order engraved nameplates, add legend code to nameplate part number.
Character height based on the number of characters and size of nameplate. Standard character size is 3/16”.
2. Nameplates with standard legends are the same list price as blank nameplates.
Nameplate Order Form on next page.
1904032203
800-262-IDEC (4332) • USA & Canada
725
ø22mm - TW Series
Switches & Pilot Devices
Custom Engraved Nameplates Order Form —TW Series
Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired.
To ensure engraving accuracy, fax it to your IDEC representative. or Distributor.
Your Company Name: _________________________________________
Your Name: _________________________________________
Telephone: _________________________________________
Fax & Email: _________________________________________
IDEC Rep/Distributor Contact: _________________________________
PO number (if known): _________________________________
IDEC Rep/Distributor Phone: _________________________________
IDEC Rep/Distributor Fax & Email: _________________________________
NWAL
Step 1.
11 characters max
(for 7/64” size letters)
7/64”
Choose Letter Size - 7/64” or 1/8”.
Letter Size
Engraving
Location
Check the box for the letter size you
want. Then write your lettering in box
below checkboxes. Note: 1/8” size
letters cannot exceed 9 characters.
9 characters max
(for 1/8” size letters)
1/8”
Letter Size
Step 2.
Sample Letter Sizes
7/64” Letters:
Specify Quantity.
Enter the number of
nameplates desired
in the box on the right.
1/8” Letters:
Qty
1
2
3
4
5
6
7
8 9 10 11
NWAQL
Step 1.
11 characters max
(for 7/64” size letters)
7/64”
Letter Size
Choose Letter Size - 7/64” or 1/8”.
Check the box for the letter size you
want. Then write your lettering in box
below checkboxes. Note: 1/8” size
letters cannot exceed 9 characters.
Engraving
Location
9 characters max
(for 1/8” size letters)
1/8”
Letter Size
Step 2.
Sample Letter Sizes
7/64” Letters:
Specify Quantity.
Enter the number of
nameplates desired
in the box on the right.
1/8” Letters:
Qty
1
2
3
4
5
6
7
8 9 10 11
NWAS
Step 1.
Choose Letter Size - 1/8” or
3/32”.
20 characters max
(for 3/32” size letters)
3/32”
Letter Size
Engraving Location A
Check the box for the letter
size you want. Then write
your lettering in box below
checkboxes. Note: 1/8” size
letters cannot exceed 14
characters.
14 characters max
(for 1/8” size letters)
1/8”
Letter Size
Engraving Location B
1
2
3
4
5
6
7
8 9 10 11 12 13 14 15 16 17 18 19 20
Step 2.
Step 3.
Sample Letter Sizes
3/32” Letters:
Specify Quantity.
Specify Location.
Enter the number of
nameplates desired
in the box on the right.
Enter the location of
engraving (A or B), in
the box on the right.
1/8” Letters:
Qty
Location
1904032203
www.IDEC.com
726
ø22mm - TW Series
Switches & Pilot Devices
Switch Engraving Order Form –TW Series
Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved.
To ensure engraving accuracy, fax it to your IDEC representative or Distributor.
Your Company:
Name:
Telephone:
Fax:
Email:
Address:
PO:
Part Number to be Engraved:
Please check one of the boxes below to indicate your choice of engraving options:
ø29mm, ø40mm Mushroom Head
Engraving
Round
Switch
Square
Switch
Engraving
Area 1
Area 2†
Letter
Height
Max. Characters
Per Line
# of
Letter
Max. Characters
Per Line
# of
Lines
Letter
Height
Max. Characters
Per Line
# of Lines
Lines Height
5/32
6
6
6
5
6
5
5/32
5
6
5
6
5
5
5/32
5
5
7
7
Engraving
Area 1
1
1
1
1
1/8
5/32
1/8
1/8
1/8
5/32
1/8
5/32
Engraving
Area 2
2
2
1/8
3
4
1/8
3
4
1/8
3/32
3/32
1. Above mentioned specifications hold true for standard size pushbuttons (round and square).
2. †Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only.
3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights.
4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters.
Enter text to be engraved:
Sample Letter Sizes
1/8 Letters:
Line 1:
Line 2:
Line 3:
Line 4:
5/32 Letters:
For IDEC Internal Use Only:
Work Order #:
1904032203
800-262-IDEC (4332) • USA & Canada
727
ø22mm - TW Series
Switches & Pilot Devices
Accessories
TW Series Accessories
Item
Appearance
Description/Usage
Part Number
Lamp Removal Tool
Rubber tool used to install or remove LED’s
OR-55
Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used
to
determine panel thickness adjustment.
Contact Block Remover
TW-KC1
TW-KQ2
Nut Locking Wrench
Metal Bezel
Used in OR-14 locking wrench to tighten locking nuts inside square bezel
Standard octagonal units (chrome-pl.)
Full shroud octagonal units (chrome-pl.)
Full shroud mushroom head units Ø 40mm
AW-R8
AW-RF8
AW-G4
Chrome plated bezels
tighten onto operator
(replacement for
damaged bezels)
Round flush units (black plastic)
AW-RP1B
AW-FP1B
AW-Q1B
Black plastic bezels for
square buttons
(replacement for
damaged bezels)
Round extended units (black plastic)
Square units (black plastic)
Plastic Bezel
Boot/Cover
Square units with full shroud (black plastic)
Waterproof lens cover for square pilot lights
AW-QF1B
APW00LN
Waterproof lens cover for square illuminated
buttons
APW00L
Used to cover and protect
pushbuttons
Clear boot for round flush units
OC-31
OC-32
Clear boot for round extended units
*In place of asterisk, specify Rubber Boot color:
B (black), G (green), R (red), Y (yellow) - (nitril
rubber)
OCW-11*
Ring to prevent operator base from rotating in the mounting hole.
Used when nameplate is not used
Anti-Rotation Ring
Mounting Hole Plug
OGL-31
Black rubber plug fills unused mounting holes in panel.
OB-31
LW9Z-BM
TW-SK
For plugging unused mounting holes in the panel. Tighten the attached locking ring to
a torque of 12 kfg-cm maximum
Degree of protection: IP66
Metallic Mounting Hole
Plug
Replacement Keys
Replacement keys (#0)
Replacement Black
Sleeve for Keyswitch
AKW2B-B
1904032203
www.IDEC.com
728
ø22mm - TW Series
Part Number
Switches & Pilot Devices
Item
Appearance
Description/Usage
Metal Button Guard
Used on flush buttons to prevent inadvertent actuation
OLW-C
Terminal Tab Adaptor
Lock-out Adaptor
Quick- connect terminals
#250 (17/64” x 3/64”) single tab
TW-FA4
HW9Z-KL1
TWN-A1R8
Used to provide lock-out protection for pushbuttons and knob selector switches:
• Up to Ø 40mm mushroom head size
(Padlock not included.)
Not applicable for e-stops.
Used to mount TW series control unit (except square units) Ø 7/8” (22mm) into a Ø
1-13/64” (30mm) panel cut-out.
22mm to 30mm Adaptor
1NC
1NO
HW-U10
HW-U01
Contact Blocks
(with side entry)
These contacts are applicable for wires terminated by ring, fork,
not recommended for bare wire connections.
HW-U01-MAU
HW-U01R
HW-U10-MAU
HW-U10R
HW-U01R-MAU
(with side entry)
HW-U10R-MAU
(with side entry)
HW-U01-F
HW-U01-MAU-F
HW-U01R-F
HW-U10-F
HW-U10-MAU-F
HW-U10R-F
Contact Blocks
(without side entry)
These contacts are applicable for wires terminated by ring, fork, or ferule terminals,
and also bare wire connections.
HW-U01R-MAU-F HW-U10R-MAU-F
(no side entry) (no side entry)
1904032203
800-262-IDEC (4332) • USA & Canada
729
ø22mm - TW Series
Switches & Pilot Devices
Dimensions
Pushbuttons
Flush
Extended
Extended with Full Shroud
Locking Ring
Safety Lever Lock
Locking Ring
Locking Ring
Safety Lever Lock
Panel Thickness
0.8 to 6
Panel Thickness 0.8 to 6
LOC
Safety Lever Lock
Panel Thickness 0.8 to 6
K
49.4 (1 block)
18.5
ø23.5
29.4
ø23.6
29.4
49.4 (1 or 2 blocks)
69.4 (3 or 4 blocks)
13
19
49.4 (1 or 2 blocks)
69.4 (3 or 4 blocks)
69.4 (2 or 3 blocks)
89.4 (4 blocks)
ø23.6
29.4
13
29mm Mushroom
40mm Mushroom
Mushroom with Full Shroud
Locking Ring
Panel Thickness
0.8 to 6
Locking Ring
Panel Thickness
0.8 to 6
Safety Lever Lock
Safety Lever Lock
Adust ring
Panel thickness 1 to 6
49.4 (1 block)
69.4 (2 or 3 blocks)
89.4 (4 blocks)
49.4 (1 block)
69.4 (2 or 3 blocks)
89.4 (4 blocks)
29.4
29.4
49.4 (1-2 blocks)
69.4 (3-4 blocks)
13
29.6
13
23
23.2
23.2
29mm Push-Lock-Turn-Reset
40mm Push-Lock-Turn-Reset
Keylock Push On/Off
Adjust ring
Panel thickness 1 to 6
Adjust ring
Adust ring
Panel thickness 1 to 6
Panel thickness 1 to 6
Reset angle 75°
Reset angle 75°
13
49.4 (1-2 blocks)
69.4 (3-4 blocks)
24.5
47
29.6
49.4 (1-2 blocks)
69.4 (3-4 blocks)
13
29.6
49.4 (1-2 blocks)
69.4 (3-4 blocks)
13
22.5
29.6
22.5
Reset (unlock)
40mm Pushlock Key reset
40mm Push-Pull
Square Flush
Adjust ring
Panel thickness 1 to 6
Adjust ring
Panel thickness 1 to 6
Locking Ring
Panel Thickness
0.8 to 6
Safety Lever Lock
LO
C
K
13
49.4 (1-2 blocks)
69.4 (3-4 blocks)
24.5
47
13
29.6
49.4 (1 block)
69.4 (2, 3 blocks)
89.4 (4 blocks)
ꢀ24.6
25
29.6
29.4
49.4 (1-2 blocks)
30.5
Reset (unlock)
13
Square Extended
Locking Ring
Safety Lever Lock
Panel Thickness 0.8 to 6
L
OC
K
49.4 (1 or 2 blocks)
69.4 (3 or 4 blocks)
13
19
ꢀ24.8
29.4
Selector Switches
Panel thickness 1 to 6
Adust ring
Adust ring
Panel thickness 1 to 6
Adust ring
Panel thickness 1 to 6
13
19
49.4 (1-2 blocks)
69.4 (3-4 blocks)
13
25
49.4 (1-2 blocks)
69.4 (3-4 blocks)
ø23.4
29.6
13
25
49.4 (1-2 blocks)
69.4 (3-4 blocks)
29.6
ø23.6
29.6
41
1904032203
www.IDEC.com
730
ø22mm - TW Series
Switches & Pilot Devices
Dimensions continued
Illuminated Pushbuttons
Extended
Extended with Full Shroud
Square Extended
Panel Thickness
1 to 6
Panel Thickness
1 to 6
Panel Thickness
1 to 6
13
13
19
30
20
30
30
20
Marking plate: ø15.5mm
Marking plate: 21mm
Marking plate: ø15.5mm
29mm Push-Turn-Reset
40mm Push-Turn-Reset
Mushroom
Panel Thickness
1 to 6
Panel Thickness
1 to 6
Panel Thickness
1 to 6
Reset Angle: 75
Reset Angle 75
13
13
13
22.5
30
30
22.5
30
22.5
Marking plate: ø13.9mm
Marking plate: ø13.9mm
Marking plate: ø13.9mm
Push-Pull
Panel Thickness
1 to 6
13
25
30
30.5
Marking plate: ø13.9mm
Illuminated Selector Switches
1 Contact Block with Full Voltage Adaptor
Transformer (2 blocks)
X1
ꢌanꢄꢈ ꢃꢍꢇꢉꢎnꢄꢋꢋ
ꢏ ꢐꢑ ꢒ
ꢀ3ꢁꢂ ꢃꢄꢅꢆꢇnaꢈ Sꢉꢅꢄꢊꢋ
X2
ꢓꢒꢁꢂ
2 Contact Blocks with Full Voltage Adaptor
Transformer (4 blocks)
ꢃ3ꢁꢂ
ꢄꢅꢆꢇꢈnaꢉ Sꢊꢆꢅꢋ
X1
ꢏanꢇꢋ ꢆꢐꢊꢌꢑnꢇꢎꢎ
ꢀ ꢒꢓ ꢂ
ꢌanꢅꢉ ꢄꢍꢈꢊꢎnꢅꢏꢏ
ꢐ ꢑꢒ ꢀꢇꢇ
ꢅ3ꢃꢄ ꢆꢇꢈꢉꢊnaꢋ Sꢌꢈꢇꢍꢎ
X1
X2
X2
ꢀꢁꢂꢃꢄ
ꢀ3ꢁꢂ
3 Contact Blocks with Full Voltage Adaptor
4 Contact Blocks with Full Voltage Adaptor
ꢄ3ꢂꢃ
ꢎanꢆꢊ ꢅꢏꢉꢋꢐnꢆꢍꢍ
ꢅꢆꢇꢈꢉnaꢊ Sꢋꢇꢆꢌꢍ
ꢑ ꢒꢓ ꢀ
X1
X2
ꢀꢁꢂꢃ
1904032203
800-262-IDEC (4332) • USA & Canada
731
ø22mm - TW Series
Switches & Pilot Devices
Dimensions continued
Pilot Lights
Round Flush APW1 Full Voltage
Round Flush APW1 Transformer
Terminal cover
APS-PVL (supplied)
Panel thickness 1 to 6
Panel thickness 1 to 6
M3.5
Terminal Screws
T transformer
13
17.2
ø23.6
29.6
59.5
28.5
34.3
13
17.2
ø23.6
29.6
Round Flush Marking Type APW1B Full Voltage
Round Flush Marking Type APW1B Transformer
M3.5 Terminal Screws
Panel thickness 1 to 6
ꢀ
Panel thickness 1 to 6
ꢀ
13
17.2
13
17.2
ø23.6
29.6
ø23.6
29.6
69.5
Dome APW2 Full Voltage
Dome APW2 Transformer
Terminal Cover
APS-PVL (supplied)
Panel thickness 1 to 6
Panel thickness 1 to 6
M3.5
Terminal Screws
T transformer
13
24.5
ø23.6
29.6
59.5
28.5
34.3
13
24.5
ø23.6
29.6
Square Flush Marking Type APQW1B Full Voltage
Square Flush Marking Type APQW1B Transformer
Terminal cover
APS-PVL (supplied)
M3.5 Terminal Screws
Panel thickness 1 to 6
Panel thickness 1 to 6
ꢀ
28.5
13.1
16
24.7
29.6
13.1
16
28.5
34.3
24.7
29.6
69.5
Illuminated Selector Switches
Adust ring
Panel thickness 1 to 6
49.4 (1 block)
69.4 (2-3 blocks)
89.4 (4blocks)
ø23.4
29.6
13
25
1904032203
www.IDEC.com
732
ø22mm - TW Series
Switches & Pilot Devices
Dimensions continued
Panel Cut-Out
Diagram
Part
Dimension
R0.8 max.
Pushbuttons
Pilot Light
• The minimum mounting centers are applicable to switches with one layer of
contact blocks (one to two contact blocks). When two layers of contact blocks
are mounted, determine the minimum mounting centers in consideration of
convenience for wiring.
+0.2
0
3.2
1*) ø40 mm mushroom button type: 40 mm minimum
1*) 2-position, 3-position lever selector switch: 39 mm minimum
1*) 4-position, 5-position lever selector switch: 50 mm minimum
Illuminated Pushbuttons
Selector Switches
30 (*1)
•When high temperature is expected, take necessary measures such as securing
sufficient mounting centers or using a cooling fan.
•The 3.2 +0.2 mm recess is for preventing rotation and is not necessary when
0
the nameplate or anti-rotation ring is not used.
All dimensions in mm.
Illuminated Selector Switches
1.The Ø 0.137” (Ø 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used.
2. *>1.404” (36mm) for 2- or 3-position.
>1.95” (50mm) for 4- or 5-position.
Accessory Dimensions
OGL-31
Anti-Rotation Ring
OLW-C
OCW-11
OB-31
Metal Button Guard
Pushbutton Rubber Boot
Mounting Hole Rubber Plug
9
9
ꢀ2ꢁ
ꢃꢄꢁꢅ
M22P1.0
M22 P1.0
ꢀ2ꢂ
Button
Button
ꢃꢂ
ꢃꢁꢅꢆ
ꢀ22ꢁꢂ
18.5
21
Extended
installed
installed
ꢀ22
ꢀ2ꢁꢂ4
ꢄꢂꢅ
Flush
HW9Z-KL1
Lock-out Adaptor
AW-RP1B
Round Plastic Bezel
AW-FP1B
Round Plastic w/Full Shroud
ꢇ2ꢔꢕ
ꢜanꢁꢅ ꢝꢃꢞꢟꢒnꢁꢑꢑ
ꢓꢔꢇ ꢉꢄ 3ꢔ2
ꢀ2ꢁ
ꢀ2ꢁ
AW-QF1B
Square Full Shroud
24 (ꢞnꢑꢞdꢁ)
3ꢀ
ꢈaꢉꢁꢊꢋꢊꢄꢄꢌ ꢍꢎꢏꢏꢁꢊ
ꢐaꢑꢒꢁꢉ ꢓꢔꢕꢉ
2ꢚꢔꢕ
3ꢓ
ꢀꢁꢂ ꢃꢄꢅꢁ ꢆꢇ
Finger-Safe Cover Dimensions
APS-PVL
22ꢂꢄ
3ꢇꢂꢅ
1904032203
800-262-IDEC (4332) • USA & Canada
733
ø22mm - TW Series
Switches & Pilot Devices
Component Construction and General Instructions —TW Series
Instructions for Switches and Pilot Devices
Lens or Button
TW Series: Adjustment for Panel Thickness
The panel thickness ring provides adjustment from 0.04” to 0.24” (1 to 6mm)
in 0.004” (0.1mm) increments. Rotate the ring until the markings around the
periphery are aligned for the desired thickness, as shown below.
Sꢈaꢉꢊ ꢋn Adꢌꢍꢎꢏꢐꢊnꢏ (ꢑn ꢀꢁꢂ ꢐꢐ)
Bezel
ꢀ
ꢀꢁꢂ
ꢀꢁ2
ꢀꢁ3
ꢀꢁ4
ꢀꢁꢃ
ꢀꢁꢄ
ꢀꢁꢅ
ꢀꢁꢆ
ꢀꢁꢇ
ꢀ
Option:
Nameplate
ꢀꢁꢂ ꢐꢐ
ꢂ
3
ꢃ
ꢒanꢊꢉ ꢓꢔꢑꢈꢕnꢊꢎꢎ Sꢈaꢉꢊ
(ꢑn ꢂ ꢐꢐ ꢋn ꢏꢔꢊ ꢋꢖꢊꢗaꢏꢋꢗ)
ꢂ ꢐꢐ
2
4
ꢄ
Operator
(Panel)
A
2
4
ꢄ
Note: When a nameplate
or an anti-rotation ring
is used, add 0.03”
(0.8mm) to the panel
thickness dimension.
3
ꢃ
3
4
ꢃ
ꢄ
Waterproof
Gasket
Waterproof Lens
(Round lens used on
square pushbuttons
ꢘꢙꢁ ꢒanꢊꢉ ꢏꢔꢑꢈꢕnꢊꢎꢎ 2ꢁꢄ ꢐꢐ
ꢘꢙꢁ ꢒanꢊꢉ ꢏꢔꢑꢈꢕnꢊꢎꢎ 2 ꢐꢐ
Adjustment Ring
Panel Thickness
and pilot lights only),
An adjustment for panel thicknesses shown below can be made quickly by using
the contact block remover tool.
Base
Panel Thickness
Adjustment Ring
Contact Block
Removal Tool
(TW-KC1)
1.6mm
2.3mm
3.5mm
LED
Lamp Holder
1mm
2mm
Contact
Block
3.2mm
Contact Block Removal Tool
Lead
Holder
Options
Full Voltage
Adaptor:
Full Size
Transformer:
1904032203
www.IDEC.com
734
ø22mm - TW Series
Switches & Pilot Devices
Instructions continued
Pilot Lights and Pushbuttons
IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up.
Octagonal and Round Bezels
Octagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons
snap onto the operator base. Mushroom buttons screw onto the operator base.
Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be
printed and placed in the lens.
Round
ꢀꢁnꢂ
Marking
Unit
ꢃaꢄꢅꢆnꢇ
ꢈꢉaꢊꢁ
Press in round flush and
Insert marking
plate under lens
extended lens.
Screw in mushroom lens
ꢈꢄꢁꢂꢂ ꢆn
Square Bezels
Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally,
install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base.
Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be
printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on.
Square
Marking
Units
Illuminated Pushbutton
Pilot Light
ꢀaꢁꢂꢃnꢄ ꢅꢆaꢇꢈ
ꢉꢈnꢊ ꢋꢈꢇaꢃnꢈꢁ
ꢌaꢇꢈꢁꢍꢁꢎꢎꢏ ꢉꢈnꢊ
Insert marking
plate under lens
Insert marking
plate under lens
ꢀaꢁꢂꢃnꢄ ꢅꢆaꢇꢈ
To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the
indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16” screwdriver into one of the recesses.
Marking Plate Engraving Area
Shape
Engraving Area
Ø 0.55” (14mm)
Ø 0.55” (14mm)
Ø 0.55” (14mm)
q 0.83” (21mm)
q 0.83” (21mm)
Used With
Illuminated pushbuttons
Pilot lights
Part Number
ALW2B
Round
APW2B
Mushroom
Square
Illuminated mushroom
Square pilot lights
ALW3B
APQW1B
ALQW2B
Square
Square illuminated pushbuttons
1904032203
800-262-IDEC (4332) • USA & Canada
735
ø22mm - TW Series
Switches & Pilot Devices
Instructions, continued
Selector Switches
The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the
handle and then press handle into the operator, as shown below.
ꢍꢀꢂꢀꢎꢎ
Press in
color insert
Press in
handle
ꢌꢁꢁꢊꢋꢇnaꢃꢀd
Sꢀꢁꢀꢂꢃꢄꢅ Sꢆꢇꢃꢂꢈ
Sꢀꢁꢀꢂꢃꢄꢅ Sꢆꢇꢃꢂꢈ
(nꢄnꢉꢇꢁꢁꢊꢋꢇnaꢃꢀd)
Remove color insert before pulling out the handle.
Standard Operating Positions
2-Postion, 90º
3-Postion, 45º
4-Postion, 45º
5-Postion, 30º
2
3
ꢁ
2
4
ꢀ
3
ꢀ
2
ꢀ
ꢁ
ꢀ
2
4
Positions: Non-Illuminated 3-Position Operators
ꢀ
2
ꢀ
ꢁ
ꢁ
ꢀ
2
ꢁ
2
Installation of LED Illuminated Units
Transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with
DC power supply to protect against surges and noise.)
Te rminal
LED Terminal
X1
X2
Diode
1904032203
www.IDEC.com
736
AOW110-S 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
AOW110-W | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW110-Y | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-B | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-G | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-R | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-S | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-W | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW111-Y | IDEC | Honeywell ZephyrTM Digital Airflow Sensors | 获取价格 | |
AOW11N60 | AOS | 600V,11A N-Channel MOSFET | 获取价格 | |
AOW11S60 | AOS | 600V 11A a MOS TM Power Transistor | 获取价格 |
AOW110-S 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8