48CTQ060STRRPBF [INFINEON]
SCHOTTKY RECTIFIER 40 Amp; 肖特基整流器40安培型号: | 48CTQ060STRRPBF |
厂家: | Infineon |
描述: | SCHOTTKY RECTIFIER 40 Amp |
文件: | 总7页 (文件大小:258K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Bulletin PD-21039 rev. A 07/06
48CTQ060SPbF
48CTQ060-1PbF
SCHOTTKY RECTIFIER
40 Amp
IF(AV) = 40Amp
VR = 60V
Description/ Features
Major Ratings and Characteristics
This center tap Schottky rectifier series has been optimized
for low reverse leakage at high temperature. The proprietary
barrier technology allows for reliable operation up to 150°C
junction temperature. Typical applications are in switching
power supplies, converters, free-wheeling diodes, and re-
verse battery protection.
Characteristics
Values
Units
I
Rectangular
waveform
40
A
F(AV)
V
I
60
V
A
V
150° C T operation
J
Center tap configuration
RRM
@ tp=5μssine
1000
0.58
FSM
Low forward voltage drop
High purity, high temperature epoxy encapsulation for
enhanced mechanical strength and moisture resistance
V
@20Apk,T =125°C
J
(perleg)
F
High frequency operation
Guard ring for enhanced ruggedness and long term
reliability
T
range
-55to150
°C
J
Lead-Free ("PbF" suffix)
Case Styles
48CTQ060SPbF
48CTQ060-1PbF
Base
Common
Cathode
2
Base
Common
Cathode
2
2
2
1
Common
Cathode
3
1
Common
Cathode
3
Anode
Anode
Anode
Anode
D2PAK
TO-262
www.irf.com
1
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
Voltage Ratings
48CTQ060SPbF
48CTQ060-1PbF
Parameters
VR
Max. DC Reverse Voltage (V)
60
VRWM Max. Working Peak Reverse Voltage (V)
Absolute Maximum Ratings
Parameters
Values Units
Conditions
IF(AV) Max. Average Forward (Per Leg)
20
A
50%duty cycle@TC =111°C,rectangular wave form
Current *SeeFig.5
(Per Device)
40
Following any rated
IFSM Max. Peak One Cycle Non-Repetitive
SurgeCurrent (Per Leg) *SeeFig.7
1000
5μs Sineor3μsRect.pulse
load condition and with
A
rated VRRM applied
260
13
10msSineor6msRect. pulse
EAS Non-Repetitive Avalanche Energy
(Per Leg)
mJ TJ = 25°C, IAS = 1.50Amps,L=11.5mH
IAR
Repetitive Avalanche Current
(Per Leg)
1.50
A
Current decaying linearly to zero in 1μsec
Frequency limited by TJ max.VA =1.5xVR typical
Electrical Specifications
Parameters
Values Units
Conditions
VFM Max. Forward Voltage Drop
0.61
0.83
0.58
V
V
V
@ 20A
TJ = 25 °C
(Per Leg) * See Fig. 1
(1)
@ 40A
@ 20A
TJ = 125 °C
0.75
2
V
@ 40A
IRM Max. Reverse Leakage Current
mA TJ = 25 °C
mA TJ = 125 °C
VR = rated VR
(Per Leg) * See Fig. 2
(1)
89
VF(TO) Threshold Voltage
0.37
8.26
1220
8.0
V
TJ = TJ max.
rt
Forward Slope Resistance
mΩ
CT
LS
Max. Junction Capacitance(Per Leg)
Typical Series Inductance (Per Leg)
pF VR = 5VDC (test signal range 100Khz to 1Mhz) 25°C
nH Measured lead to lead 5mm from package body
V/ μs (Rated VR)
dv/dt Max. Voltage Rate of Change
10000
(1) Pulse Width < 300μs, Duty Cycle <2%
Thermal-Mechanical Specifications
Parameters
Values Units
Conditions
TJ
Max. Junction Temperature Range
-55to150
-55to150
2.0
°C
°C
Tstg Max. Storage Temperature Range
RthJC Max. Thermal Resistance Junction
toCase (Per Leg)
°C/W DC operation
RthJC Max. Thermal Resistance Junction
toCase(Per Package)
1.0
°C/W DC operation
RthCS Typical Thermal Resistance, Case
toHeatsink
0.50
°C/W Mounting surface,smooth and greased
(only for TO-220)
wt
T
Approximate Weight
Mounting Torque
2(0.07) g(oz.)
Min.
6(5)
Kg-cm
(Ibf-in)
Max.
12(10)
Marking Device
48CTQ060S
48CTQ060-1
CasestyleD2Pak
CasestyleTO-262
2
www.irf.com
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
1000
1000
100
10
T = 150°C
J
100
125°C
10
1
100°C
75°C
50°C
25°C
0.1
0.01
0.001
T = 150°C
J
0
10
20
30
40
50
60
T = 125°C
J
Reverse Voltage - V (V)
R
T = 25°C
J
Fig.2-Typical Values Of Reverse Current
Vs. Reverse Voltage (PerLeg)
10000
1000
100
T = 25°C
J
1
0
0.2 0.4 0.6 0.8
1
1.2 1.4 1.6 1.8
2
2.2
0
10
20
30
40
50
60
Forward Voltage Drop - V (V)
FM
Reverse Voltage - V (V)
R
Fig.1-Max. Forward Voltage Drop Characteristics
(PerLeg)
Fig.3-Typical Junction Capacitance
Vs. Reverse Voltage (PerLeg)
10
D = 0.75
D = 0.50
D = 0.33
D = 0.25
D = 0.20
1
0.1
P
DM
t
1
t
2
Notes:
Single Pulse
(Thermal Resistance)
1. Duty factor D = t / t
2
1
2. Peak T = PDMx Z
+ T
C
thJC
J
0.01
0.00001
0.0001
0.001
0.01
0.1
1
10
100
t
, Rectangular Pulse Duration (Seconds)
1
Fig.4-Max. Thermal Impedance ZthJC Characteristics (PerLeg)
3
www.irf.com
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
150
140
20
15
10
5
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC
130
RM S Lim i t
120
DC
Square wave (D = 0.50)
110
80%Rated V applied
R
100
see note (2)
90
0
0
5
10
15
20
25
30
0
5
10
15
20
25
30
Average Forward Current - I
(A)
F(AV)
Average Forward Current - I
(A)
F( AV)
Fig. 5-Max. Allowable CaseTemperature
Vs. Average Forward Current (PerLeg)
Fig.6-Forward Power Loss Characteristics
(PerLeg)
1000
At Any Rated Load Condition
And With Rated V Applied
RRM
Following Surge
100
10
100
1000
10000
Square Wave Pulse Duration - t (microsec)
p
Fig.7-Max. Non-Repetitive Surge Current (PerLeg)
L
HIG H- SPEED
SWITCH
IRFP460
DUT
FREE- WHEEL
DIODE
Rg = 25ohm
Vd = 25 Volt
+
C URRENT
MONITOR
40HFL40S02
Fig.8-Unclamped Inductive Test Circuit
(2) Formulaused:TC=TJ -(Pd+PdREV)xRthJC
;
Pd=ForwardPowerLoss=IF(AV) xVFM @(IF(AV) /D) (seeFig.6);
PdREV =InversePowerLoss=VR1 xIR(1-D); IR @VR1=10V
4
www.irf.com
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
Outlines Table
Conformto JEDECoutlineD2Pak(SMD-220)
Dimensions in millimeters and (inches)
Modified JEDEC outline TO-262
Dimensions in millimeters and (inches)
5
www.irf.com
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
Part Marking Information
D2PAK
PART NUMBER
DATE CODE
INTERNATIONAL
RECTIFIER
LOGO
THIS IS A 48CTQ060S
LOT CODE 8024
ASSEMBLED ON WW 02, 2000
48CTQ060S
YEAR 0 = 2000
WEEK 02
ASSEMBLY
LOT CODE
P = LEAD-FREE
TO-262
PART NUMBER
INTERNATIONAL
RECTIFIER
LOGO
EXAMPLE: THIS IS A 48CTQ060-1
LOT CODE 1789
DATE CODE
ASSEMBLED ON WW 19, 2002
YEAR 2 = 2002
WEEK 19
P = LEAD-FREE
ASSEMBLY
LOT CODE
Tape & Reel Information
Dimensionsinmillimetersand(inches)
6
www.irf.com
48CTQ060SPbF, 48CTQ060-1PbF
Bulletin PD-21039 rev. A 07/06
Ordering Information Table
Device Code
48
C
T
Q
060
S TRL PbF
5
6
8
1
2
4
7
3
1
2
-
Current Rating (40A)
Circuit Configuration
C = Common Cathode
T = TO-220
-
3
4
5
6
-
-
-
-
Schottky "Q" Series
Voltage Rating (060 = 60V)
y S = D2Pak
y -1= TO-262
7
8
-
-
y none = Tube (50 pieces)
y TRL = Tape & Reel (Left Oriented - for D2Pak only)
y TRR = Tape & Reel (Right Oriented - for D2Pak only)
y none = Standard Production
y PbF = Lead-Free
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level and Lead-Free.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 07/06
7
www.irf.com
相关型号:
©2020 ICPDF网 联系我们和版权申明