5962-9550101HZC [INFINEON]
DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, FM-12;型号: | 5962-9550101HZC |
厂家: | Infineon |
描述: | DC-DC Regulated Power Supply Module, 2 Output, 80W, Hybrid, FM-12 局域网 输出元件 |
文件: | 总14页 (文件大小:174K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
REVISIONS
LTR
A
DESCRIPTION
DATE (YR-MO-DA)
05-02-07
APPROVED
Update drawing to reflect current requirements.
Raymond Monnin
Raymond Monnin
B
Figure 2, Terminal connections; Changed the terminal symbol, pin 9
from "Return Sense" to "Negative Output" and terminal symbol, pin 10
from "Positive Sense" to "Output Voltage Trim". -sld
05-06-15
Corrected dimensions for symbols D, D2, and L1 for case outline U.
Corrected dimensions for symbols D2, L, and L1 for case outline X.
Corrected dimensions for symbols D, L, and L1 for case outline Y.
Corrected dimensions for symbols D, D2, and L1 for case outline Z.
Added footnote 1 to table II, under group C end-point electricals.
Updated drawing paragraphs. -sld
C
13-04-09
Charles F. Saffle
REV
SHEET
REV
SHEET
REV STATUS
OF SHEETS
REV
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
C
C
C
C
SHEET
10
11
12
13
PREPARED BY
Steve Duncan
CHECKED BY
Michael Jones
PMIC N/A
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
http://www.dscc.dla.mil
STANDARD
MICROCIRCUIT
DRAWING
APPROVED BY
Kendall A. Cottongim
THIS DRAWING IS
AVAILABLE
MICROCIRCUIT, HYBRID, LINEAR, 5 VOLT,
DUAL CHANNEL, DC/DC CONVERTER
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
DRAWING APPROVAL DATE
98-12-16
AMSC N/A
REVISION LEVEL
SIZE
A
CAGE CODE
5962-95501
C
67268
SHEET
1 OF 13
DSCC FORM 2233
APR 97
5962-E222-13
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962
-
95501
01
H
X
X
RHA
designator
(see 1.2.1)
Federal
stock class
designator
\
Device
type
Device
class
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
(see 1.2.2)
designator
(see 1.2.3)
/
\/
Drawing number
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
01
Generic number
AFL27005D/CH
Circuit function
DC/DC converter, 80 W, ±5 V output
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level.
All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K,
and E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
K
Device performance documentation
Highest reliability class available. This level is intended for use in space
applications.
H
G
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C and D).
E
D
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must
be specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
Terminals
Package style
U
X
Y
Z
See figure 1
See figure 1
See figure 1
See figure 1
12
12
12
12
Y case configuration with leads bent upwards
Straight leads with end mounting through holes
Straight leads with side mounting through holes
Y case configuration with leads bent downwards
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-95501
A
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
2
DSCC FORM 2234
APR 97
1.3 Absolute maximum ratings. 1/
Input voltage range.......................................................................... -0.5 V dc to +500 V dc
Lead temperature (soldering, 10 seconds)...................................... +300°C
Storage temperature range ............................................................. -65°C to +135°C
1.4 Recommended operating conditions.
Input voltage range.......................................................................... +160 V dc to +400 V dc
Output power 2/ 3/......................................................................... ≤ 80 W
Case operating temperature range (TC) .......................................... -55°C to +125°C
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at https://assist.dla.mil/quicksearch/ or from the Standardization Document
Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. The
manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as
defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not
affect the form, fit, or function of the device for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38534 and herein.
1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
2/ Derate output power linearly above case temperature +125°C to 0 at +135°C.
3/ Output load must be distributed so that a minimum of 20% of the total output power is being provided by one of the outputs.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
3
DSCC FORM 2234
APR 97
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample,
for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those
which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be
made available to the preparing activity (DLA Land and Maritime-VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime-VA shall affirm that the
manufacturer's product meets the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as
modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form,
fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime-VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1015 of MIL-STD-883.
(2) T as specified in accordance with table I of method 1015 of MIL-STD-883.
A
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
4
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions
Group A
Subgroups
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
C
VIN = 270 V dc ±5%, CL = 0
unless otherwise specified
Min
Max
Output voltage
VOUT
IOUT = 8 A
1
01
±4.95
±4.90
±5.05
±5.10
12.8
V
A
2,3
Output current 1/
IOUT
VIN = 160, 270, and 400 V dc,
either output
1,2,3
01
01
Output ripple voltage 2/
VRIP
VIN = 160, 270, and 400 V dc,
B.W. = 10 MHz, IOUT = 8 A,
both outputs
1,2,3
1,2,3
1,2,3
1,2,3
60
±25
±50
mV p-p
mV
Line regulation 3/
Load regulation 3/
VRLINE
VRLOAD
VRCROS
VIN = 160, 270, and 400 V dc,
IOUT = 0, 4, and 8 A,
both outputs
01
01
01
VIN = 160, 270, and 400 V dc,
IOUT = 0, 4, and 8 A,
both outputs
mV
Cross regulation 4/
Positive output
VIN = 160, 270, and 400 V dc
±50
mV
mA
Negative output
±400
Input current
IIN
IOUT = no load
1
01
10
12
3
2,3
Enable 1, (pin 4) shorted to
Input return (pin 2)
1,2,3
Enable 2, (pin 12) shorted to
Output return (pin 8)
1,2,3
5
Input ripple current 2/
Efficiency
IRIP
EFF
IOUT = 8 A, B.W. = 10 MHz
1,2,3
1
01
01
60
mA p-p
%
IOUT = 8 A, both outputs,
TC = +25°C
78
Isolation
ISO
Input to output or any pin to
case (except pin 3) at 500 V dc,
TC = +25°C
1
01
100
MΩ
Maximum capacitive
load 5/
CL
PD
Each output, TC = +25°C
4
01
01
10,000
µF
Power dissipation load
fault
Overload 6/
Short circuit
1,2,3
30
30
W
See footnotes at end of table.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-95501
A
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
5
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
Group A
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
Subgroups
C
VIN = 270 V dc ±5%, CL = 0
unless otherwise specified
Min
9.2
Max
10.0
Current limit point 7/
ICL
VOUT = 90 %VNOM
1
2
01
A
8.4
9.2
3
10.0
11.2
Switching frequency
Sync frequency range
FS
4,5,6
4,5,6
01
01
500
600
kHz
kHz
FSYNC
500
700
Output response to step
transient load changes
8/
VOTLOAD 50% to/from 100%
10% to/from 50%
4,5,6
01
-450
-450
+450
mV pk
+450
200
Recovery time, step
transient load changes
8/ 9/
TTLOAD
50% to/from 100%
10% to/from 50%
4,5,6
01
µs
400
Output response to
transient step line
changes 5/ 10/
VOTLINE
Input step 160 V to/from 400 V
dc
4,5,6
4,5,6
01
01
-500
+500
mV pk
Recovery time transient
step line changes
5/ 8/ 10/
TTLINE
Input step, 160 V to/from 400 V
dc
500
µs
Turn on overshoot
Turn on delay 11/
Load fault recovery 5/
VTonos
TonD
TrLF
Enable 1 and 2 on. (Pins 4 and
12 high or open)
4,5,6
4,5,6
4,5,6
01
01
01
250
120
120
mV pk
ms
Enable 1 and 2 on. (Pins 4 and
12 high or open)
ms
1/ Parameter guaranteed by line and load regulation tests.
2/ Bandwidth guaranteed by design. Tested for 20 kHz to 10 MHz.
3/ Load current split equally between +VOUT and -VOUT
.
4/ Cross regulation measured with load on tested output at 20% while changing the load on the other output from 20%
to 80%.
5/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter,
parameters shall be guaranteed to the limits specified in table I.
6/ An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short
circuit protection and is the condition of maximum power dissipation.
7/ Current limit point is that condition of excess load causing output voltage to drop 90% of nominal.
8/ Load step transition time ≥ 10 microseconds.
9/ Recovery time is measured from the initiation of the transient to where VOUT has returned to within ± 1% of
VOUT at 50% load.
10/ Input step transition time ≥ 100 microseconds.
11/ Turn on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-95501
A
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
6
DSCC FORM 2234
APR 97
Case U
Millimeters
Inches
Symbol
A
Min
Max
9.65
Min
Max
.380
2.833
2.505
.535
1.505
2.01
1.005
.055
.43
D
70.35
63.37
13.08
37.97
50.6
25.27
1.14
10.4
71.96
63.63
13.59
38.23
51.1
25.53
1.40
10.9
2.770
2.495
.515
1.495
1.99
.995
.045
.41
D1
D2
E
e1
e2
F
L
L1
q
5.33
5.84
.210
1.745
1.145
1.745
.24
.295
.370
.245
.035
.135
.230
1.755
1.155
1.755
.26
.305
.380
.255
.045
.145
44.32
29.08
44.32
6.1
7.49
9.40
6.22
0.89
3.43
44.58
29.34
44.58
6.6
7.75
9.65
6.48
1.14
3.68
q1
q2
q3
q4
q5
S
∅b
∅p
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-
pound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s).
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
7
DSCC FORM 2234
APR 97
Case X
Millimeters
Inches
Symbol
A
Min
Max
9.65
Min
Max
.380
D
76.07
63.37
76.33
63.63
76.23
38.23
5.21
2.995
2.495
3.005
2.505
3.001
1.505
.205
D1
D2
E
e1
F
L
37.97
4.95
1.14
1.495
.195
.045
1.40
.055
.248
6.30
L1
q
q1
S
∅b
∅p
5.34
69.98
31.88
6.22
5.84
.210
2.755
1.255
.245
.230
70.23
32.13
6.48
2.765
1.265
.255
0.89
1.14
3.38
.035
.045
.133
3.12
.123
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-
pound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline - Continued.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
8
DSCC FORM 2234
APR 97
Case Y
Millimeters
Inches
Symbol
A
Min
Max
9.65
76.23
63.63
38.23
51.1
5.21
1.40
6.30
5.84
44.58
29.34
44.58
6.6
Min
Max
.380
D
3.001
2.505
1.505
2.01
.205
.055
.248
.230
1.755
1.155
1.755
.26
D1
E
e1
e2
F
L
L1
q
q1
q2
q3
q4
q5
S
63.37
37.97
50.6
2.495
1.495
1.99
4.95
.195
.045
1.14
5.34
44.32
29.08
44.32
6.1
7.49
9.40
6.22
0.89
3.43
.210
1.745
1.145
1.745
.24
7.75
9.65
6.48
1.14
3.68
.295
.370
.245
.035
.135
.305
.380
.255
.045
.145
∅b
∅p
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-
pound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) – Continued.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
9
DSCC FORM 2234
APR 97
Case Z
Millimeters
Inches
Symbol
A
Min
Max
9.65
71.96
63.63
13.59
38.23
51.1
25.53
1.40
9.4
Min
Max
.380
2.833
2.505
.535
1.505
2.01
1.005
.055
.37
D
70.35
63.37
13.08
37.97
50.6
25.27
1.14
8.9
2.770
2.495
.515
1.495
1.99
.995
.045
.35
D1
D2
E
e1
e2
F
L
L1
q
5.33
44.32
29.08
44.32
6.1
7.49
9.40
6.22
0.89
3.43
5.84
44.58
29.34
44.58
6.6
7.75
9.65
6.48
1.14
3.68
.210
1.745
1.145
1.745
.24
.295
.370
.245
.035
.135
.230
1.755
1.155
1.755
.26
.305
.380
.255
.045
.145
q1
q2
q3
q4
q5
S
∅b
∅p
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-
pound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) - Continued.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
10
DSCC FORM 2234
APR 97
Device type
Case outlines
01
U,X,Y,Z
Terminal number
Terminal symbol
1
2
3
4
5
6
7
8
9
Positive Input
Input Return
Case
Enable 1
Sync Output
Sync Input
Positive Output
Output Return
Negative Output
10
Output Voltage Trim
11
12
Share
Enable 2
FIGURE 2. Terminal connections.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-95501
A
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
11
DSCC FORM 2234
APR 97
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A
test table)
Interim electrical parameters
Final electrical parameters
Group A test requirements
---
1*, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6
1, 2, 3, 4
Group C end-point electrical
parameters 1/
End-point electrical parameters for
Radiation Hardness Assurance
(RHA) devices
Not applicable
1/ As a minimum, for all Group C testing performed after (13-04-09)
manufacturers shall perform subgroups 1, 2, and 3 from the Group A
electrical test table (Table C-Xa of MIL-PRF-38534).
* PDA applies to subgroup 1.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. Tests shall be as specified in table II herein.
b. Subgroups 7, 8, 9, 10, and 11 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test, method 1005 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime-VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1005 of MIL-STD-883.
(2) T as specified in accordance with table I of method 1005 of MIL-STD-883.
A
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-95501
A
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
12
DSCC FORM 2234
APR 97
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF-
38534.
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this list
will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices
(FSC 5962) should contact DLA Land and Maritime-VA, telephone (614) 692-8108.
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime-VA, Columbus, Ohio 43218-3990,
or telephone (614) 692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors, listed in MIL-HDBK-
103 and QML-38534, have submitted a certificate of compliance (see 3.7 herein) to DLA Land and Maritime-VA and have
agreed to this drawing.
SIZE
STANDARD
5962-95501
A
MICROCIRCUIT DRAWING
REVISION LEVEL
SHEET
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
C
13
DSCC FORM 2234
APR 97
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 13-04-09
Approved sources of supply for SMD 5962-95501 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime -VA. This information
bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. DLA Land and Maritime
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/.
Standard
Microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
Similar
PIN 2/
5962-9550101HUA
5962-9550101HUC
5962-9550101HXA
5962-9550101HXC
5962-9550101HYA
5962-9550101HYC
5962-9550101HZA
5962-9550101HZC
52467
52467
52467
52467
52467
52467
52467
52467
AFL27005DW/CH
AFL27005DW/CH
AFL27005DX/CH
AFL27005DX/CH
AFL27005DY/CH
AFL27005DY/CH
AFL27005DZ/CH
AFL27005DZ/CH
1/ The lead finish shown for each PIN representing hermetic package is the most
readily available from the manufacturer listed for that part. If the desired lead finish
is not listed contact the vendor to determine its availability.
2/ Caution. Do not use this number for item acquisition. Items acquired to this number
may not satisfy the performance requirements of this drawing.
Vendor CAGE
number
Vendor name
and address
52467
International Rectifier Corporation
2520 Junction Ave.
San Jose, CA 95134
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.
相关型号:
©2020 ICPDF网 联系我们和版权申明