70CRU04 [INFINEON]
Ultrafast Rectifier; 超快整流器型号: | 70CRU04 |
厂家: | Infineon |
描述: | Ultrafast Rectifier |
文件: | 总6页 (文件大小:116K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Bulletin PD-20637 12/01
70CRU04
Ultrafast Rectifier
Features
trr = 38ns
IF(AV) = 70Amp
@TC = 116°C
VR = 400V
• Two Common-Cathode Diodes
• Ultrafast Reverse Recovery
• Ultrasoft Reverse Recovery Current Shape
• Low Forward Voltage Drop
• Low Leakage Current
• Optimized for Power Conversion: Welding and Industrial SMPS Applications
• Up to 175°C Operating Junction Temperature
Description/ Applications
The 70CRU04 integrates two state-of-the-art International Rectifier’s Ultrafast recovery rectifiers in the common-
cathode configuration. The planar structure of the diodes, and the platinum doping life-time control, provide a
Ultrasoft recovery current shape, together with the best overall performance, ruggedness and reliability
characteristics.
These devices are thus intended for high frequency applications in which the switching energy is designed not to be
predominant portion of the total energy, such as in the output rectification stage of Welding machines, SMPS, DC-
DC converters. Their extremely optimized stored charge and low recovery current reduce both over-dissipation in
the switching elements (and snubbers) and EMI/RFI.
Absolute Maximum Ratings
Parameters
Max
Units
VR
Cathode to Anode Voltage
400
V
IF(AV)
IFSM
PD
Continuous Forward Current
TC = 116°C
Per Diode
Per Diode
Per Module
35
A
Single Pulse Forward Current TC = 25°C
Maximum Power Dissipation TC = 100°C
300
47
W
TJ, TSTG Operating Junction and Storage Temperatures
- 55 to 175
°C
Case Styles
70CRU04
TO-218
Base
Common
Cathode
2
1
3
Anode
1
Anode
2
2
Common
Cathode
1
www.irf.com
70CRU04
Bulletin PD-20637 12/01
Electrical Characteristics per Diode @ T = 25°C (unless otherwise specified)
J
Parameters
Min Typ Max Units Test Conditions
VBR, Vr
VF
Breakdown Voltage,
Blocking Voltage
400
-
-
V
IR = 100µA
Forward Voltage
-
-
1.11 1.32
0.98 1.14
V
V
IF = 35A
IF = 35A, TJ = 125°C
-
-
-
-
0.92 1.05
V
IF = 35A, TJ = 175°C
VR = VR Rated
IR
Reverse Leakage Current
Junction Capacitance
-
-
100
µA
mA
pF
2
-
TJ = 150°C, VR = VR Rated
VR = 400V
CT
70
Dynamic Recovery Characteristics per Diode @ T = 25°C (unless otherwise specified)
J
Parameters
Min Typ Max Units Test Conditions
IF = 1A
trr
Reverse Recovery Time
-
32
38
ns
ns
A
TJ = 25°C
VR = 30V
diF /dt = 200A/µs
trr
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
-
-
-
-
-
-
72
-
-
-
-
-
-
TJ = 25°C
TJ = 125°C
TJ = 25°C
TJ = 125°C
TJ = 25°C
TJ = 125°C
130
7.7
IF = 35A
VR = 200V
diF /dt = 200A/µs
IRRM
16.5
0.28
1.08
Qrr
µC
Thermal - Mechanical Characteristics
Parameters
Min
-
Typ
0.8
0.4
0.2
4
Max
1.6
0.8
-
Units
K/W
RthJC
RthJC
RthCS
Wt
Thermal Resistance, Junction to Case
Thermal Resistance, Junction to Case
Thermal Resistance, Case to Heatsink
Weight
Per Diode
Both Diodes
-
(1)
-
-
-
g
-
0.13
-
-
(oz)
T
Mounting Torque
1.2
10
2.4
20
N * m
lbf.in
-
!(1) Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
70CRU04
Bulletin PD-20637 12/01
1000
100
10
1000
100
10
Tj = 175˚C
150˚C
125˚C
25˚C
1
0.1
0.01
0.001
50 100 150 200 250 300 350 400
Reverse Voltage-VR (V)
Tj = 175˚C
Tj = 125˚C
Tj = 25˚C
Fig.2-Typical Values Of Reverse Current
Vs. Reverse Voltage
1000
Tj = 25˚C
100
10
1
1
10
100
1000
0
0.5
1
1.5
2
2.5
3
Forward Voltage Drop-VFM (V)
Reverse Voltage-VR (V)
Fig.3-Typical Junction Capacitance
Vs. Reverse Voltage
Fig.1-Typical Forward Voltage Drop Characteristics
(PerDiode)
10
1
P
DM
t
1
t
2
0.1
Single Pulse
(Thermal Resistance)
Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01
0.0001
0.001
0.01
0.1
1
10
t1,Rectangular Pulse Duration (Seconds)
Fig.4-Max. Thermal Impedance ZthJC Characteristics(PerDiode)
3
www.irf.com
70CRU04
Bulletin PD-20637 12/01
180
170
160
150
140
40
35
30
25
20
15
10
5
RMS Limit
DC
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC
130
Square wave (D = 0.50)
Rated Vr applied
120
110
100
see note (3)
0
0
5
10 15 20 25 30 35 40
Average Forward Current - I F(AV)(A)
0
5
10 15 20 25 30 35
Average Forward Current - I F(AV)(A)
Fig.5-Max. Allowable CaseTemperature
Vs. Average Forward Current
Fig.6-Forward Power Loss Characteristics
150
2500
If = 35A
Vrr = 200V
If = 35A
Vrr = 200V
140
130
120
110
100
90
2000
1500
1000
500
0
Tj = 125˚C
Tj = 125˚C
80
Tj = 25˚C
Tj = 25˚C
70
60
50
100
1000
100
1000
di F /dt (A/µs)
Fig.7-TypicalReverseRecovery vs.di F /dt
diF/dt (A/µs)
Fig.8-TypicalStoredCharge vs.diF /dt
(3) Formulaused:TC =TJ -(Pd+PdREV)xRthJC
;
Pd=ForwardPowerLoss=IF(AV) xVFM @(IF(AV) /D) (seeFig.6);
PdREV =InversePowerLoss=VR1 xIR (1-D); IR @VR1=ratedVR
4
www.irf.com
70CRU04
Bulletin PD-20637 12/01
Outline Table
Dimensions in inches (and milimetres)
Marking Information
ASSEMBLY LOT CODE
IR PART NUMBER
70CRU04
INTERNATIONAL RECTIFIER LOGO
0136
1043
DATE CODE (YYWW)
YY = YEAR
WW = WEEK
5
www.irf.com
70CRU04
Bulletin PD-20637 12/01
Ordering Information Table
Device Code
70
C
R
U
04
2
4
5
1
3
1
2
3
4
5
-
-
-
-
-
Current Rating
Common Cathode
TO-218
Ultrafast Recovery
Voltage Rating
(70 = 70A)
(04 = 400V)
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 12/01
6
www.irf.com
相关型号: