ARH2802R5DCK [INFINEON]

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS;
ARH2802R5DCK
型号: ARH2802R5DCK
厂家: Infineon    Infineon
描述:

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS

DC-DC转换器
文件: 总12页 (文件大小:191K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PD-95887B  
ARH28XXS SERIES  
28V Input, Single Output  
HYBRID - HIGH RELIABILITY  
RADIATION HARDENED  
DC-DC CONVERTERS  
Description  
The ARH Series of DC-DC converters has been  
designed specifically for use in the hostile environments  
The high level of radiation tolerance inherent in the  
ARH design is the result of extensive research, thorough  
analysis and testing and of careful component  
specification. Designed to supplement the triple output  
configuration provided by the ART series, the ARH  
circuit topology is the follow-on to the successful ART  
design and incorporates many of the design features  
characterizing that product line. Capable of uniform  
high performance over long term exposures in radiation  
intense environments, this series expands the standard  
for distributed power systems demanding high  
performance and reliability in the harsh environments.  
ARH  
Features  
n Total Dose > 100 krad (Si), 2:1 Margin  
n SEE Hardened to LET up to 83 MeV.cm2/mg  
n Derated per MIL-STD-975 & MIL-STD-1547  
n Output Power to 30 Watts  
n Regulates to No-Load  
n 18 to 50 Volt Input Range  
n Input Undervoltage Lockout  
n Fully Characterized from -55°C to +125°C  
n Continuous Short Circuit Protection  
The ARH converters are hermetically sealed in a  
rugged, low profile package utilizing copper core input  
and output pins to minimize resistive DC losses. Long-  
term hermeticity is assured through use of parallel seam  
welded lid attachment along with rugged ceramic pin-  
to-package seal. Axial orientation of the leads facilitates  
preferred bulkhead mounting placing the converter on  
the principal heat-dissipating surface.  
n 12.8 W/in3 Output Power Density  
n True Hermetic Package  
n External Inhibit Port  
n Externally Synchronizable  
n Fault Tolerant Design  
n Available with Outputs from 2.5V to 15V  
n Overload Protection  
Manufactured in a facility fully qualified to MIL-PRF-  
38534, these converters are fabricated utilizing DLA  
Land and Martiime qualified processes. For available  
screening options, refer to device screening table in  
the data sheet.  
n Standard Microcircuit Drawings Available  
Variations in electrical, mechanical and screening  
specifications can be accommodated. Contact IR San  
Jose for special requirements.  
www.irf.com  
1
06/14/13  
ARH28XXS Series  
28V Input, Single Output  
Specifications  
Absolute Maximum Ratings  
Recommended Operating Conditions  
+18V to +60VDC  
Input Voltage range  
-0.5V to +80VDC  
Input Voltage range  
+18V to +50V for full derating to MIL-STD-1547  
Soldering temperature  
300°C for 10 seconds Output Power  
0 to 30W  
Storage case temperature -65°C to +135°C  
-55°C to +125°C  
Operating case temperature  
-55°C to +85°C for full derating to MIL-STD-975  
Electrical Performance -55°C < TCASE < +125°C, VIN = 28V±5%, CL = 0 unless otherwise specified.  
Limit  
MIN  
Limit  
MAX  
Parameter  
Symbol  
Test Conditions  
POUT = 30 W, TC = +25°C  
Units  
Output voltage accuracy  
VOUT  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
2.487  
3.283  
4.975  
2.513  
3.317  
5.025  
Vdc  
ARH2805R2S  
ARH2812S  
ARH2815S  
5.174  
11.940  
14.925  
5.226  
12.060  
15.075  
Output power  
POUT  
18 Vdc < VIN < 50Vdc  
18 Vdc < VIN < 50Vdc  
0
30  
W
Output current  
ARH2802R5S  
IOUT  
0
0
0
0
0
0
12000  
9090  
6000  
5770  
2500  
2000  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
ARH2815S  
mAdc  
Line regulation Note 3  
VRLINE  
18 Vdc < VIN < 50Vdc, 0 < IOUT < IMAX  
18 Vdc < VIN < 50Vdc, 0 < IOUT < IMAX  
-1.0  
-2.0  
+1.0  
+2.0  
%
Load regulation Note 4  
Total regulation  
VRLOAD  
%
%
All conditions of Line, Load, Temperature,  
Radiation and End of Life  
VR  
-4.0  
+4.0  
I
OUT = 0 (Pin 3 open)  
100  
8.0  
No-load input current  
IIN  
mA  
inhibited (Pin 3 shorted to pin 2)  
18 Vdc < VIN < 50Vdc, IOUT = IMAX  
Output ripple and noise voltage  
Note 5  
VRIP  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
30  
30  
40  
40  
50  
50  
mVp.p  
ARH2815S  
For Notes to Specifications, refer to page 4  
2
www.irf.com  
ARH28XXS Series  
28V Input, Single Output  
Electrical Performance -55°C < TCASE < +125°C, VIN = 28V±5%, CL = 0 unless otherwise specified. (Continued)  
Limit  
MIN  
Limit  
MAX  
Parameter  
Input ripple current Note 5  
Switching frequency  
Symbol  
Test Conditions  
18 Vdc < VIN < 50Vdc, IOUT = IMAX  
Synchronization input open. (pin 6)  
IOUT = IMAX, TC = +25°C  
Units  
mAp.p  
KHz  
IRIP  
FS  
100  
275  
225  
Efficiency  
Eff  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
ARH2815S  
72  
75  
76  
76  
80  
80  
%
Enable Input  
open circuit voltage  
drive current (sink)  
voltage range  
3.0  
5.0  
100  
50  
V
µA  
V
-0.5  
Synchronization Input  
frequency range  
pulse high level  
pulse low level  
External clock signal on Sync. input (pin 4)  
225  
3.5  
-0.5  
40  
310  
10  
0.25  
KHz  
V
V
µ
pulse rise time  
pulse duty cycle  
V/ s  
20  
80  
%
Synchronization Output  
pulse high level  
Signal compatible with Synchronization Input  
Short circuit on output  
3.7  
4.3  
V
Power dissipation, Short circuit  
ARH2802R5S  
PD  
10  
W
ARH2803R3S & ARH2805S  
All Others  
12  
9.5  
100% load  
Output response to step load  
VTLD  
50% Load  
changes  
Note 8  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
ARH2815S  
-200  
-200  
-200  
-200  
-300  
-350  
200  
200  
200  
200  
300  
350  
mVPK  
Recovery time from step load  
TTLD  
50% Load 100% load  
changes  
Notes 8, 9  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
200  
200  
200  
200  
200  
200  
µs  
ARH2805R2S  
ARH2812S  
ARH2815S  
Output response to step line  
VTLN  
IOUT = IMAX, VIN = 18 V to/from 50 V  
changes  
Notes 7, 10  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
-180  
-180  
-250  
-250  
-450  
-900  
180  
180  
250  
250  
450  
900  
mVPK  
ARH2815S  
For Notes to Specifications, refer to page 4  
www.irf.com  
3
ARH28XXS Series  
28V Input, Single Output  
Electrical Performance -55°C < TCASE < +125°C, VIN = 28V±5%, CL = 0 unless otherwise specified. (Continued)  
Limit  
MIN  
Limit  
MAX  
Parameter  
Symbol  
Test Conditions  
Units  
Recovery time from step line  
TTLN  
IOUT = IMAX, VIN = 18 V to/from 50 V  
changes  
Notes 7, 9, 10  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
600  
600  
700  
700  
320  
400  
µs  
ARH2805R2S  
ARH2812S  
ARH2815S  
Turn on overshoot  
VOS  
TDLY  
CL  
IOUT = 10% or 100% of IMAX  
IOUT = 10% or 100% of IMAX  
No effect on DC performance  
5.0  
20  
%Vout  
ms  
Turn on delay Note 11  
2.0  
Capacitive load Notes 6, 7  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
1200  
1200  
1000  
1000  
180  
µF  
ARH2805R2S  
ARH2812S  
ARH2815S  
120  
Isolation  
ISO  
Vr  
500VDC Input to Output or any pin to case  
100  
105  
MΩ  
Recovery from a short circuit  
Output shorted, then open into max rated load  
current. Vin = 28 V  
10  
% of  
Rated  
Output  
Voltage  
Overload Trip Current  
Ovld  
Maximum current at specified output voltage  
135  
% of  
Max  
Output  
Current  
Notes to Specifications Tables  
1.  
2.  
Operation outside absolute maximum/minimum limits may cause permanent damage to the device. Extended operation at the  
limits may permanently degrade performance and affect reliability.  
Device performance specified in Electrical Performance table is guaranteed when operated within recommended limits. Operation  
outside recommended limits is not specified.  
3. Parameter measured from 28V to 18V or to 50V while load remains fixed at 10%, 50% and 100% of Imax.  
4. Parameter measured from 50% to 10% or 100% of maximum load conditions while line remains fixed at 18, 28 or 50 volts.  
5. Guaranteed for a bandwidth of DC to 20 MHz. Tested using a 20 KHz to 2.0 MHz bandwidth.  
6. A capacitive load of any value from 0 to the specified maximum is permitted without compromise to DC performance. A  
capacitive load in excess of the maximum limit may interfere with the proper operation of the converter’s short circuit protection,  
causing erratic behavior during turn on.  
7.  
Parameter is tested as part of design characterization or after design or process changes. Thereafter, parameters shall be  
guaranteed to the limits specified in the table.  
8. Load transient rate of change, di/dt 2.0 A/µs.  
9. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.  
10. Line transient rate of change, dv/dt 50 V/µs.  
11. Turn on delay time is for either a step application of input power or a logical low to high transition on the enable pin (pin 3) while  
power is present at the input.  
4
www.irf.com  
ARH28XXS Series  
28V Input, Single Output  
Group A Tests VIN = 28V, CL = 0 unless otherwise specified.  
Group A  
Subgroups  
Limit  
MIN  
Limit  
MAX  
Test  
Symbol  
Test Conditions  
Units  
Output voltage accuracy  
VOUT  
1
IOUT = IMAX , T = 25°C  
c
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
2.487  
3.283  
4.975  
5.174  
11.940  
14.925  
2.513  
3.317  
5.025  
5.226  
12.060  
15.075  
V
ARH2815S  
Output power Note 1  
POUT  
IOUT  
VIN = 18 V, 28V, 50 V  
VIN = 18 V, 28V, 50 V  
1, 2, 3  
1, 2, 3  
0
30  
W
Output current Note 1  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
0
0
0
0
0
0
12000  
9090  
6000  
5770  
2500  
2000  
mA  
ARH2815S  
Output regulation Note 4  
VR  
I
V
OUT = 10%, 50%, 100% of IMAX  
IN = 18 V, 28V, 50 V  
1, 2, 3  
2.425  
3.201  
4.850  
5.044  
11.640  
14.550  
2.575  
3.399  
5.150  
5.356  
12.360  
15.450  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
V
ARH2815S  
IOUT = 0, Pin 3 open  
1, 2, 3  
1, 2, 3  
100  
8.0  
No Load Input Current  
IIN  
mA  
Pin 3 shorted to pin 2 (disabled)  
VIN = 18 V, 28V, 50 V  
Output ripple Note 2  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
VRIP  
IOUT = IMAX  
1, 2, 3  
30  
30  
40  
40  
50  
50  
mVP-P  
ARH2805R2S  
ARH2812S  
ARH2815S  
Switching frequency  
Input ripple Note 2  
FS  
Synchronization pin (pin 6) open  
VIN = 18 V, 28V, 50 V  
4, 5, 6  
1, 2, 3  
225  
105  
275  
100  
KHz  
IRIP  
mAP-P  
IOUT = IMAX  
Recovery from a short  
circuit  
Vr  
Output shorted, then open into max rated  
load current. Vin = 28 V  
5.0  
% of Rated  
Output  
Voltage  
Overload Trip Current  
Ovld  
Maximum current at specified output  
voltage  
1, 2, 3  
135  
% of Max  
Output  
Current  
For Notes to Group A Tests, refer to page 6  
www.irf.com  
5
ARH28XXS Series  
28V Input, Single Output  
Group A Tests VIN = 28V, CL = 0 unless otherwise specified. (continued)  
Group A  
Subgroups  
Limit  
MIN  
Limit  
MAX  
Test  
Symbol  
Test Conditions  
Units  
Efficiency  
Eff  
IOUT = IMAX  
1
72  
75  
76  
76  
80  
80  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
%
ARH2815S  
2, 3  
68  
68  
72  
72  
78  
78  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
ARH2805R2S  
ARH2812S  
ARH2815S  
Power dissipation,  
Short circuit  
ARH2802R5S  
PD  
Short circuit across output  
1, 2, 3  
4, 5, 6  
10  
12  
W
ARH2803R3S & ARH2805  
All Others  
9.5  
Output response to step  
load changes Note 5  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
VTL  
50% Load to/from 100% load  
-200  
-200  
-200  
-200  
-300  
-350  
200  
200  
200  
200  
300  
350  
mVPK  
ARH2805R2S  
ARH2812S  
ARH2815S  
Recovery from step load  
changes Notes 5, 6  
ARH2802R5S  
ARH2803R3S  
ARH2805S  
TTL  
50% Load to/from 100% load  
4, 5, 6  
200  
200  
200  
200  
200  
200  
µs  
ARH2805R2S  
ARH2812S  
ARH2815S  
Turn on overshoot  
Turn on delay Note 7  
Isolation  
VOS  
TDLY  
ISO  
IOUT = 10% and 100%  
4, 5, 6  
4, 5, 6  
1
5.0  
20  
%Vout  
ms  
IOUT = minimum and full rated  
2.0  
500VDC Input to output or any pin to  
case (except pin 12)  
100  
M  
Notes to Specifications Tables  
1.  
Paramete verified during dynamic load regulation tests.  
2. Guranteed for DC to 20 MHz bandwidth. Test conducted using a 20 KHz to 2.0MHz bandwidth.  
3. Deleted .  
4. Output is measured for all combinations of line and load. Only the minimum and meximum readings for the ouput are recorded.  
5. Load step transition time is 10µs.  
6. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.  
7. Turn on delay time is tested by application of a logical low on high transition on teh enable pin (pin 3) with power present at the  
input.  
8. Subgroups 1 and 4 are performed at +25°C, subgroups 2 and 5 at +85°C and subgroups 3 and 6 at -55°C.  
6
www.irf.com  
ARH28XXS Series  
28V Input, Single Output  
Figure I. Block Diagram  
EMI  
Filter  
1
11 12  
+Vout  
+Input  
Under-Voltage  
Detector  
13 14  
Output  
Return  
10  
Level  
Translator  
& Buffer  
Primary Bias  
& Reference  
+Sense  
3
9
Enable  
Overload  
& Short  
Circuit  
-Sense  
+
Error  
Amp  
4
Sample  
& Hold  
Sync In  
-
Pulse Width  
Modulator  
5
Sync Out  
Input  
Return  
2
Circuit Operation and Application Information  
The ARH28XXS series of converters have been designed  
using a single ended forward switched mode converter  
topology. (Refer to Figure I.) Single ended topologies enjoy  
certain advantages in radiation hardened designs in that  
they eliminate the possibility of simultaneous turn on of  
both switching elements during a radiation induced upset.  
In addition, single ended topologies are not subject to  
transformer saturation problems often associated with  
double ended implementations.  
Other key circuit design features include output short circuit  
and overload protection, input undervoltage lockout and  
an external synchronization input port, permitting operation  
at an externally set clock rate. Alternately, a synchronization  
output is provided to lock frequencies with another  
converter when using more than one converter in a system.  
Thermal Considerations  
The ARH series of converters is capable of providing  
relatively high output power from a package of modest  
volume. The power density exhibited by these devices is  
obtained by combining high circuit efficiency with effective  
methods of heat removal from the die junctions. Good  
design practices have effectively addressed this  
requirement inside the device. However when operating  
at maximum loads, heat generated at the die junctions  
depends upon minimally restricted thermal conduction from  
the base plate for that heat to be carried away. To maintain  
case temperature at or below the specified maximum of  
125°C, this heat can be transferred by attachment of the  
ARH28XXS to an appropriate heat dissipater held in intimate  
contact with the converter base-plate.  
The design incorporates a two-stage LC input filter to  
attenuate input ripple current. A low overhead linear bias  
regulator provides both a bias voltage for the converter  
primary control logic and a stable, well-regulated reference  
for the error amplifier. Output control is realized using a  
wide band discrete pulse width modulator control circuit  
incorporating a unique non-linear ramp generator circuit.  
This circuit helps stabilize loop gain over variations in line  
voltage for superior output transient response. Nominal  
conversion frequency has been selected as 250 KHz to  
maximize efficiency and minimize magnetic element size.  
Output voltages are sensed and fed back to the controller  
using a patented magnetic feedback circuit. This circuit is  
designed to be relatively insensitive to variations in  
temperature, aging, radiation and manufacturing tolerances  
making it particularly well suited to radiation hardened  
designs. The control logic has been designed to use only  
radiation tolerant components, and current paths include  
series resistances to limit photocurrents.  
Effectiveness of this heat transfer is dependent on the  
intimacy of the baseplate to heatsink interface. It is therefore  
suggested that a heat-transferring medium possessing  
good thermal conductivity be inserted between the  
baseplate and heatsink. A material utilized at the factory  
during testing and burn-in processes is sold under the  
www.irf.com  
7
ARH28XXS Series  
28V Input, Single Output  
1
®
trade name of Sil-Pad 400 . This particular product is an  
insulator but electrically conductive versions are also  
available. Use of these materials assures optimum surface  
contact with the heat dissipater by compensating for minor  
surface variations. While other available types of heat  
conducting materials and thermal compounds provide  
similar effectiveness, these alternatives are often less  
convenient and are sometimes messy to use.  
Inhibiting Converter Output  
As an alternative to application and removal of the DC  
voltage at the input, the user can control the converter  
output by providing an input referenced, TTL compatible,  
logic signal to the enable pin 3. This port is internally pulled  
“high” so that when not used, an open connection on the  
pin permits normal converter operation. When inhibited  
outputs are desired, a logical “low” on this port will shut the  
converter down. An open collector device capable of  
sinking at least 100 µA connected to enable pin 3 will work  
well in this application.  
A conservative aid to estimating the total heat sink surface  
) required to set the maximum case  
temperature rise (DT) above ambient temperature is given  
area (A  
HEAT SINK  
by the following expression:  
A benefit of utilization of the enable input is that following an  
initial charge of the input capacitor, subsequent turn-on  
commands will induce no uncontrolled current inrush.  
1.43  
T  
A
HEAT SINK  
5.94  
80P0.85  
where  
Figure II. Enable Input Equivalent Circuit  
T = Case temperature rise above ambient  
1
P = Device dissipation in Watts = POUT  
1  
Eff  
As an example, assume that it is desired to maintain the  
case temperature of an ARH2815S at +65°C or less while  
operating in an open area whose ambient temperature  
does not exceed +35°C; then  
T = 65 - 35 = 35°C.  
From the Specification Table, the worst case full load  
efficiency for this device is 80%; therefore the maximum  
power dissipation at full load is given by  
1
P = 30•  
1 = 300.25 = 7.5W  
(
)
.80  
and the required heat sink area is  
Synchronization  
1.43  
When using multiple converters, system requirements may  
dictate operating several converters at a common system  
frequency. To accommodate this requirement, the  
ARH28XXS type converter provides a synchronization  
input port.  
35  
A
HEAT SINK  
=
5.94 = 31.8 in2  
807.50.85  
Thus, a total heat sink surface area (including fins, if any)  
of approximately 32 in in this example, would limit case  
2
rise to 35°C above ambient. A flat aluminum plate, 0.25"  
thick and of approximate dimension 4" by 4" (16 in per  
The sync input port permits synchronization of an ARH  
converter to any compatible external frequency source  
operating in the band of 225 to 310 KHz. In the event of  
failure of an external synchronization source, the converter  
will revert to its own internally set frequency. When external  
synchronization is not desired, the sync in port may be left  
open (unconnected) permitting the converter to operate at  
2
side) would suffice for this application in a still air  
environment. Note that to meet the criteria, both sides of  
the plate require unrestricted exposure to the ambient air.  
The user should remember that when operating in the  
vacuum of space, this method does not apply and all heat  
must be conducted away from the attaching surface.  
its own internally set frequency.  
1
Sil-Pad is a registered Trade Mark of Bergquist, Minneapolis, MN  
8
www.irf.com  
ARH28XXS Series  
28V Input, Single Output  
When an external frequency source is not available, an  
internal clock signal is provided through appropriate  
buffering at the sync out port. This port can drive a  
minimum of 3 ARH sync in ports thereby allowing all to  
EMI Filtering  
Although the internal filtering provided at both input and  
output terminals of the ARH series converters is sufficient  
for most applications, some critical applications may  
require additional filtering in order to accommodate particular  
system requirements.  
operate at the same clock frequency.  
Output Short Circuit Protection  
While the internal input filter maintains input ripple current  
below 50 mAp-p, an external filter can be applied to further  
attenuate this ripple to a level below the CE03 limits imposed  
by MIL-STD-461. International Rectifier currently supplies  
such a filter housed in a complementary package. The  
Protection against accidental short circuits on the output  
is provided in the ARH28XXS converter. This protection is  
implemented by sensing primary switching current and  
reducing the switching pulse widths when a short occurs.  
The output current is therefore limited to a maximum value,  
which protects the converter. Under this condition the  
internal power dissipation is nearly the same as for  
maximum loading.  
catalog number of this part is ARF461.  
Output Noise  
When attempting noise measurement at the output of  
switching converters, measurement techniques employed  
can have a significant influence on results during these  
tests. Any noise measurements should be undertaken  
only with test leads dressed as close to the device output  
pins as is physically possible. Probe ground leads should  
be kept to a minimum (<< 1") length to minimize the influence  
Input Undervoltage Protection  
A minimum voltage is required at the input of the converter  
to initiate operation. This voltage is set to a nominal value  
of 16.8 volts. To preclude the possibility of noise or other  
voltage variations at the input falsely initiating and halting  
converter operation, a hysteresis of approximately 1.0  
volts is incorporated into this circuit. The converter is  
guaranteed to operate at 18 Volts input under all specified  
conditions.  
of parasitic impedances on results.  
Input Filter  
To attenuate input ripple current, the ARH28XXS series  
converters incorporate a two-stage LC input filter illustrated  
in Figure III following. The elements of this filter comprise  
the dominant input load impedance characteristic, and  
therefore determine the nature of the current inrush at  
turn-on.  
Figure III. Input Filter  
www.irf.com  
9
ARH28XXS Series  
28V Input, Single Output  
Radiation Performance  
A principal design goal was achieving a converter topology  
that, because of large design margins, had radiation  
performance essentially independent of radiation induced  
element-lot performance variations. Where such margins  
cannot be assured, element lots are either selected  
following RLAT characterization as radiation hard devices  
or, purchased as radiation hard devices so that realization  
of the design goals are maintained.  
The radiation tolerance characteristics inherent in the  
ARH28XXS converters are a result of a carefully planned  
ground-up design program with specific radiation design  
goals. Identification of the general circuit topology, a  
fundamental task in the design effort, was followed by  
selection of appropriate elements from a list of devices for  
which extensive radiation effects data was available. By  
imposing sufficiently large margins on those electrical  
parameters showing the worst case degrading effects of  
radiation, designers were able to select appropriate  
elements for incorporation into the circuit. Existing radiation  
data was utilized for input to PSPICE and RadSPICE in the  
generation of circuit performance verification analyses.  
Thus, electrical performance capability under all  
environmental conditions including radiation was well  
understood before first application of power to the inputs.  
.
The following table specifies guaranteed minimum radiation  
exposure levels tolerated while maintaining specification  
limits.  
Radiation Specification Tcase = 25°C  
Test  
Conditions  
MIL-STD-883, Method 1019.4  
Total Ionizing Dose (2.:1 Margin) Operating bias applied during exposure  
Min  
Typ  
Unit  
100  
Krads(Si)  
Dose Rate  
MIL-STD-883, Method 1021  
Temporary Saturation  
Survival  
1E8  
Rads(Si)/sec  
1E11  
Heavy Ions  
BNL Dual Van de Graf Generator  
2
(Single Event Effects)  
83  
MeV cm /mg  
International Rectifier currently does not have a DLA Land and Maritime certified Radiation Hardness  
Assurance Program.  
Standard Quality Conformance Inspections on ARH28XXS Series (Filght Screened)  
Inspection  
Application  
Samples  
Group A  
Group B  
Group C  
Group D  
Part of screening on each unit  
Each inspection lot  
100%  
* 5 units  
10 units  
3 units  
First inspection lot or following Class 1 change  
In line (Part of element evaluation)  
* Group B quantity for option 2 End of Line QCI. No Group B samples required for Option 1, In-line.  
10  
www.irf.com  
ARH28XXS Series  
28V Input, Single Output  
Mechanical Outline  
Ø 0.136 – 6 HOLES  
0.040  
PIN DIA.  
6 X 0.200  
=1.200  
2.200  
1.675  
1.950  
0.375  
0.138  
0.300  
1.40  
0.150  
2.400  
2.700  
0.275 MAX.  
3.25 REF.  
MAX  
0.050  
0.500 MAX.  
Note:  
1. Dimensions are in inches.  
2. Base Plate Mounting Plane Flatness 0.003 maximum.  
3. Unless otherwise specified, tolerances are  
.XX  
.XXX  
= ± 2°  
= ± .01  
= ± .005  
4. Device Weight - 120 grams maximum.  
Pin Designation  
Standard Microcircuit Drawing Equivalence Table  
Standard Microcircuit  
Drawing Number  
5962-04232  
IR Standard  
Part Number  
ARH2805S  
Pin #  
Designation  
1
2
+ Input  
Input Return  
Enable  
5962-04233  
ARH2803R3S  
3
4
Sync In  
5
Sync Out  
Chassis  
8
9
-Sense  
10  
11  
12  
13  
14  
+Sense  
+V Output  
+V Output  
Output Return  
Output Return  
www.irf.com  
11  
ARH28XXS Series  
28V Input, Single Output  
Device Screening  
Requirement  
MIL-STD-883 Method  
No Suffix  
CK  
EM  
Temperature Range  
Element Evaluation  
Non-Destructive Bond Pull  
Internal Visual  
-55°C to +85°C  
Class K  
Yes  
-55°C to +85°C  
Class K  
Yes  
-55°C to +85°C  
MIL-PRF-38534  
2023  
N/A  
N/A  
2017  
Yes  
Yes  
Temperature Cycle  
Constant Acceleration  
PIND  
1010  
Cond C  
Cond C  
3000 Gs  
Cond A  
Cond C  
3000 Gs  
N/A  
2001, Y1 Axis  
2020  
3000 Gs  
Cond A  
320 hrs @ 125°C  
( 2 x 160 hrs )  
-55°C, +25°C,  
+85°C  
320 hrs @ 125°C 48 hrs @ 125°C  
( 2 x 160 hrs )  
Burn-In  
1015  
Final Electrical  
( Group A )  
MIL-PRF-38534  
& Specification  
MIL-PRF-38534  
1014  
-55°C, +25°C,  
+85°C  
2%  
-55°C, +25°C,  
+85°C  
PDA  
2%  
N/A  
Seal, Fine and Gross  
Radiographic  
External Visual  
Cond A, C  
Yes  
Cond A, C  
Yes  
Cond A  
N/A  
2012  
2009  
Yes  
Yes  
Notes:  
Best commercial practice.  
CK is DLA class K compliant without radiation performance. No Suffix is a radiation rated device but not available  
as a DLA qualified SMD per MIL-PRF-38534.  
International Rectifier currently does not have a DLA certified Radiation Hardness Assurance Program.  
Part Numbering  
ARH 28 05 S /EM  
Model  
Screening Level  
(Please refer to Screening Table)  
Input Voltage  
No Suffix, CK, EM  
Nominal  
28 = 28V  
Output  
S = Single  
D = Dual  
Output Voltage  
02R5 = 2.5V, 03R3 = 3.3V  
05 = 5V, 05R2 = 5.2V  
12 = 12V, 15 = 15V  
WORLD HEADQUARTERS: 101 N, Sepulveda Blvd., El Segundo, California 90245, USA Tel: (310) 252-7105  
IR SAN JOSE: 2520 Junction Avenue, San Jose, California 95134, USA Tel: (408) 434-5000  
Visit us at www.irf.com for sales contact information.  
Data and specifications subject to change without notice. 06/2013  
12  
www.irf.com  

相关型号:

ARH2802R5DEM

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2802R5S

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC/DC CONVERTERS
INFINEON

ARH2802R5S/CK

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC/DC CONVERTERS
INFINEON

ARH2802R5S/EM

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC/DC CONVERTERS
INFINEON

ARH2802R5SCK

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2802R5SEM

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2803R3DCK

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2803R3DEM

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2803R3S

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON

ARH2803R3S/CK

DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, HERMETIC SEALED PACKAGE-14
INFINEON

ARH2803R3S/EM

DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, PACKAGE-14
INFINEON

ARH2803R3SCK

HYBRID - HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTERS
INFINEON