ATR2800T [INFINEON]

HYBRID-HIGH RELIABILITY DC/DC CONVERTER;
ATR2800T
型号: ATR2800T
厂家: Infineon    Infineon
描述:

HYBRID-HIGH RELIABILITY DC/DC CONVERTER

文件: 总6页 (文件大小:132K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PD-94551D  
ATR28XXT SERIES  
28V Input, Triple Output  
HYBRID-HIGH RELIABILITY  
DC/DC CONVERTER  
Description  
The ATR28XXT Series of DC/DC converters provide  
30W of output power over the full military temperature  
range with no derating. These devices are pin  
compatible with the ATO series converters but offer  
twice the maximum output power in a lower profile  
package. A custom CMOS ASIC pulse width modulator  
operating at a nominal switching frequency of 550KHz  
combined with a unique magnetic feedback reduces  
circuit complexity for enhanced reliability. These  
converters provide 500V input to output isolation and  
operate in highly efficient single forward mode.  
ATR  
Features  
n 30W Output Power  
n Flexible Output Loading  
n -55°C to +125°C Operation  
n Pin Compatible with ATO  
n 0.410” Maximum Height  
n 16V to 40VDC Input Range  
n 500V Input to Output Isolation  
n High Audio Rejection  
n MIL-STD-704 Compatible  
n Load Fault Protection - Short Circuit and  
Overload  
The advanced feedback design and high operating  
frequency provide an extremely wide bandwidth control  
loop with high gain and phase margin. This results in  
fast dynamic line and load response as well as superior  
audio rejection. The control loop is compensated to  
provide optimum performance over the full military  
temperature range and over the 16V to 40V input voltage  
range.  
n TTL level Compatible Synchronization  
n Standard Microcircuit Drawings Available  
These converters are protected against both continuous  
output short circuits and output overload. Either load  
fault condition will result in operating in a low power  
dissipation foldback mode. The converters will shut  
down for approximately 15ms, then attempt to restart.  
This cycle will continue indefinitely unless the load fault  
is corrected. Recovery to normal operation is automatic  
upon removal of the load fault.  
Manufactured in a facility full qualified to MIL-PRF-38534,  
these converters are fabricated utilizing DSCC qualified  
processes. For available screening options, refer to  
device screening table in the data sheet. Variations in  
electrical, mechanical and screening can be limited  
accomodated. Contact IR Santa Clara with specific  
requirements.  
www.irf.com  
1
08/06/07  
ATR28XXT Series  
Specifications  
TCASE = -55°C to +125°C, VIN = +28V ± 5% unless otherwise specified  
Absolute Maximum Ratings  
Input voltage  
-0.5V to +50VDC  
Internally limited, 37.5W typical  
300°C  
Power Output  
Lead temperature  
Storage temperature  
-65°C to +135°C  
Conditions  
ATR2812T  
ATR2815T  
-55°C TC +125°C,  
VIN = 28 VDC ±5%, CL=0,  
unless otherwise specified  
Symbol  
Test  
Units  
Min  
Max  
Min  
Max  
STATIC CHARACTERISTICS  
OUTPUT  
Voltage1  
VOUT  
4.95  
4.90  
11.88  
±11.76  
100  
5.05  
5.10  
12.12  
±12.24  
4000  
4.95  
4.90  
14.85  
±14.70  
100  
5.05  
5.10  
15.15  
±15.30  
4000  
VDC  
VDC  
VDC  
VDC  
mA  
I
OUT = 0 (main) +25°C  
over temp. range  
I
over temp. range  
VIN = 16, 28, and 40VDC  
(main)  
OUT = 0 (dual)1 +25 C  
°
±
±
±
±
Current1,2,3,4  
IOUT  
VIN = 16, 28, and 40VDC  
0.0  
0.0  
mA  
±625  
±500  
(dual)1  
Ripple1,5  
VRIP  
VIN = 16, 28, and 40VDC  
(dual)  
60  
40  
60  
40  
mVp-p  
mVp-p  
BW = 20Hz to 2MHz (main)  
V
IN = 16, 28, and 40 VDC  
BW = 20Hz to 2 MHz (dual)  
REGULATION  
Line1,3  
VRLINE  
VIN = 16, 28, and 40 VDC  
P
OUT = 0.5, 7.5, 15W (main)  
±25  
±60  
±25  
±75  
VIN = 16, 28, and 40VDC  
(dual)  
P
OUT = 1.2/1.5, 7.5 and 15W  
(dual)  
mV  
Load1,3  
VRLOAD  
VIN = 16, 28, and 40 VDC  
P
OUT = 0.5, 7.5, 15W (main)  
VIN = 16, 28, and 40 VDC  
OUT = 1.2/1.5, 7.5, and 15W  
(dual)  
±50  
±60  
±50  
±75  
P
INPUT  
Current  
IIN  
I
OUT = 0, inhibit (pin 8)  
Tied to input return (pin 10)  
OUT = 0, inhibit (pin 8) =  
open  
OUT = 3000mA (main)  
OUT = 15W (dual)  
BW = 20Hz to 2MHz  
OUT = 3000mA (main) +25°C  
OUT = 15W (dual)  
15  
75  
15  
75  
mA  
mA  
I
Ripple Current4  
IRIP  
I
P
50  
50  
mAp-p  
%
EFFICIENCY  
ISOLATION  
EFF  
75  
72  
75  
72  
I
P
over temp. range  
Input to output or any pin to  
case  
ISO  
100  
100  
MΩ  
(except pin 8)at 500  
TC=+25°C  
Load Fault Power Dissipation3  
PD  
Overload  
14  
14  
9.0  
600  
700  
Short circuit  
9.0  
600  
700  
W
KHz  
KHz  
Switching Frequency  
SYNC Frequency Range  
FS  
FSYNC  
500  
500  
500  
500  
50% load to/from 100% load  
no load to/from 50% load  
Inhibit Open Circuit Voltage  
Output Response to  
Step transient  
VOI  
9.0  
13  
9.0  
13  
V
mVpk  
VOTLOAD  
TTLOAD  
50% load to/from 100% load  
No load to/from 50% load  
50% load to/from 100% load  
No load to 50% load  
-500  
-1000  
+500  
+1000  
200  
5.0  
10  
-500  
-1000  
+500  
+1000  
200  
5.0  
10  
Load changes7  
Recovery Time Step  
Step transient  
µs  
ms  
ms  
Load changes7,8  
50% load to no load  
For Notes to Specifications, refer to page 3  
2
www.irf.com  
ATR28XXT Series  
Specifications  
TCASE = -55°C to +125°C, VIN = +28V ± 5% unless otherwise specified  
Absolute Maximum Ratings  
Input voltage  
-0.5V to +50VDC  
Power Output  
Internally limited, 37.5W typical  
300°C for 10 seconds  
Soldering temperature  
Temperature Range6  
Operating case temperature  
Storage case temperature  
-55°C to +135°C  
-65°C to +135°C  
Conditions  
-55°C TC +125°C,  
ATR2812T  
ATR2815T  
Test  
Symbol  
±
IN = 28 VDC 5%, CL=0,  
V
unless otherwise specified  
Min  
Max  
Min  
Max  
Units  
Output Response to  
Transient step9  
VOTLINE  
Input step 16 from/to 40 VDC  
IOUT = 3000mA (main)  
POUT = 15W (dual)  
Input step 16 from/to 40 VDC  
IOUT = 3000mA (main)  
POUT = 15W (dual)  
IOUT = 0, and 3000mA (main)  
POUT = 0, 15W (dual)  
IOUT = 0, 3000mA (main)  
POUT = 0, 15W (dual)  
mV pk  
±1500  
±1500  
Line changes10  
Recovery Time8  
Transient step9  
Line changes10  
Turn on Overshoot1  
TTLINE  
10  
10  
ms  
VTonOS  
TonD  
1000  
1000  
mV pk  
Turn on Delay 1, 11  
25  
25  
65  
25  
25  
65  
ms  
ms  
g
Load Fault Recovery10  
Device weight  
TRLF  
Notes to Specifications  
1. Tested at each output.  
2. Parameter guaranteed byline and load regulation tests.  
3. Although operation with no load is permissible, light loading on the main (+5V) output may cause the output voltage of the auxiliary  
outputs (±12V or ±15V) to drop out of regulation. It is therefore recommended that at least 100mA or 20% of the output power,  
whichever is greater, be taken from the main (+5V) output and at least 50mA (or ±12V: 1.2W, ±15V: 1.5W) of the output power is  
taken from the auxiliary (±12V or ±15V) .  
4. Total combined output power –30W.  
5. Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.  
6. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the overload protection  
circuit and is the condition of maximum power dissipation.  
7. Load step transition time between 2.0µs and 10µs.  
8. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.  
9. Input step transition time between 2.0µs to 10µs.  
10. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be  
guaranteed to the limits specified in the table.  
11. Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the  
inhibit pin (pin 8) while power is applied to the input.  
www.irf.com  
3
ATR28XXT Series  
Block Diagram  
5
+Vout  
-Vout  
+Input  
EMI  
Tracking  
Regulator  
1
Filter  
4
2
Enable Input  
8
Primary  
Housekeeping  
Supply  
+5Vdc  
Output  
Case  
7
Output  
Return  
3
Drive  
Sync Input  
9
Error  
Amp &  
Ref  
Pulse Width  
Modulator  
FB  
CS  
Input Return  
10  
Standard Microcircuit Drawing Equivalence Table  
Standard Microcircuit  
Vendor Cage  
Code  
IR Standard  
Part Number  
ATR2815T  
Drawing Number  
5962-92159  
52467  
5962-93158  
ATR2812T  
52467  
4
www.irf.com  
ATR28XXT Series  
Mechanical Outlines  
1.000  
0.05  
0.040 D X  
0.26 L Pins  
2.700  
Max  
4 X 0.400  
=1.600  
2.360  
1.95  
0.410  
Max  
1.350  
Max  
Pin Designation  
Pin #  
Designation  
+ Input  
1
2
+5Vdc Output  
Output Return  
- Dual Output  
+ Dual Output  
NC  
3
4
5
6
7
Case Ground  
Enable Input  
Sync Input  
8
9
10  
Input Return  
www.irf.com  
5
ATR28XXT Series  
Device Screening  
Requirement  
MIL-STD-883 Method No Suffix  
ES  
HB  
CH  
Temperature Range  
Element Evaluation  
Non-Destructive  
Bond Pull  
-20°C to +85°C -55°C to +125°C  
-55°C to +125°C -55°C to +125°C  
MIL-PRF-38534  
2023  
N/A  
N/A  
N/A  
N/A  
Class H  
N/A  
N/A  
N/A  
Internal Visual  
Temperature Cycle  
Constant Acceleration  
PIND  
2017  
1010  
Yes  
Cond B  
500 Gs  
N/A  
Yes  
Cond C  
3000 Gs  
N/A  
Yes  
Cond C  
3000 Gs  
N/A  
N/A  
N/A  
2001, Y1 Axis  
2020  
N/A  
Burn-In  
1015  
N/A  
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C  
Final Electrical  
( Group A )  
MIL-PRF-38534  
& Specification  
MIL-PRF-38534  
1014  
25°C  
25°C  
-55°C, +25°C,  
+125°C  
N/A  
-55°C, +25°C,  
+125°C  
10%  
PDA  
N/A  
Cond A  
N/A  
N/A  
Cond A, C  
N/A  
Seal, Fine and Gross  
Radiographic  
External Visual  
Cond A, C  
N/A  
Cond A, C  
N/A  
2012  
2009  
Yes  
Yes  
Yes  
Notes:  
 Best commercial practice  
‚ Sample tests at low and high temperatures  
ƒ -55°C to +105°C for AHE, ATO, ATW  
Part Numbering  
ATR 28 15 T F /CH  
Screening Level  
Model  
(Please refer to Screening Table)  
No Suffix, ES, HB, CH  
Input Voltage  
Nominal  
28 = 28V  
Package Style  
F = Flange  
Blank = Non-Flanged  
Output Voltage  
12 = 5V ±12V  
Output  
T = Triple  
15 = 5V ±15V  
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105  
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500  
Visit us at www.irf.com for sales contact information.  
Data and specifications subject to change without notice. 08/2007  
6
www.irf.com  

相关型号:

ATR2800T_15

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ATR2803R3S

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ATR2803R3S/HB

DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid,
INFINEON

ATR2803R3SFCH

HYBRID - HIGH RELIABILITY DC-DC CONVERTER
INFINEON

ATR2803R3SFES

HYBRID - HIGH RELIABILITY DC-DC CONVERTER
INFINEON

ATR2803R3SFHB

HYBRID - HIGH RELIABILITY DC-DC CONVERTER
INFINEON

ATR2805D

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON

ATR2805D/CH

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON

ATR2805D/ES

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON

ATR2805D/HB

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON

ATR2805DF

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON

ATR2805DF/CH

ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS
INFINEON