ATR2812SF/ES [INFINEON]
ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS; 先进的模拟混合高可靠性DC / DC转换器型号: | ATR2812SF/ES |
厂家: | Infineon |
描述: | ADVANCED ANALOG HYBRID-HIGH RELIABILITY DC/DC CONVERTERS |
文件: | 总6页 (文件大小:49K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD - 94551
ATR28XXT SERIES
28V Input, Triple Output
ADVANCED ANALOG
HYBRID-HIGH RELIABILITY
DC/DC CONVERTERS
Description
The ATR28XXT Series of DC/DC converters provide
30 watts of output power over the full military tempera-
ture range with no derating. These devices are pin
compatible with the Advanced Analog ATO series con-
verters but offer twice the maximum output power in a
lower profile package. A custom CMOS ASIC pulse
width modulator operating at a nominal switching fre-
quency of 550KHz combined with a unique magnetic
feedback reduces circuit complexity for enhanced reli-
ability. These converters provide 500 volt input to out-
put isolation and operate in highly efficient single for-
ATR
Features
n 30 Watt Output Power
n Flexible Output Loading
n -55°C to +125°C Operation
n Pin Compatible with ATO
n 0.410” Maximum Height
n 16 to 40 VDC Input Range
n 500 Volt Input to Output Isolation
n High Audio Rejection
n MIL-STD-704 Compatible
n Load Fault Protection - Short Circuit and
Overload
ward mode.
The advanced feedback design and high operating fre-
quency provide an extremely wide bandwidth control
loop with high gain and phase margin. This results in
fast dynamic line and load response as well as supe-
rior audio rejection. The control loop is compensated
to provide optimum performance over the full military
temperature range and over the 16 to 40 volt input
voltage range.
n TTL level Compatible Synchronization
These converters are protected against both continu-
ous output short circuits and output overload. Either
load fault condition will result in operating in a low power
dissipation foldback mode. The converters will shut
down for approximately 15 milliseconds, then attempt
to restart. This cycle will continue indefinitely unless
the load fault is corrected. Recovery to normal opera-
tion is automatic upon removal of the load fault.
Manufactured in a facility full qualified to MIL-PRF-
38534, these converters are available in four screen-
ing grades to satisfy a wide range of requirements. The
CH grade is fully compliant to the requirements of MIL-
PRF-38534 for class H. The HB grade is processed
and screened to the class H requirement, but element
evaluation and Periodic Inspections (PI) are not re-
quired. Both grades are tested to meet the complete
group “A” test specification over the full military tem-
perature range without output power deration.
Two grades with more limited screening are also
available for use in less demanding applications.
Variations in electrical, mechanical and screen-
ing can be limited accomodated. Contact
Advanced Analog with specific requirements.
www.irf.com
1
10/08/02
ATR28XXT Series
Specifications
TCASE = -55°C to +125°C, VIN = +28V ± 5% unless otherwise specified
ABSOLUTE MAXIMUM RATINGS1
Input Voltage Range
Power Dissipation
Lead Temperature
Storage Temperature
-0.5V to 50VDC
Internal limited 37.5W
+300°C
-65°C to 150°C case
Conditions
ATR2812T
ATR2815T
-55 C TC +125 C,
°
≤
≤
°
Symbol
Test
V
IN = 28 V
5%, C =0,
±
unless otheDrCwise speLcified
Units
Min
Max
Min
Max
STATIC CHARACTERISTICS
OUTPUT
Voltage1
VOUT
4.95
4.90
11.88
11.76
100.0
0.0
5.05
5.10
12.12
12.24
4000
4.95
4.90
14.85
14.70
100.0
0.0
5.05
5.10
15.15
15.30
4000
VDC
VDC
VDC
VDC
mA
mA
IOUT = 0 (main) +25 C
°
over temp. range
IOUT = 0 (dual)1 +25 C
°
±
±
±
±
±
±
±
±
over temp. range
Current1,2,3,4
Ripple1,5
IOUT
VIN = 16, 28, and 40VDC (main)
VIN = 16, 28, and 40VDC (dual)1
VIN = 16, 28, and 40VDC (dual)
BW = 20Hz to 2MHz (main)
VIN = 16, 28, and 40 VDC
BW = 20Hz to 2 MHz (dual)
625
500
±
±
VRIP
60
60
mVp-p
mVp-p
40
40
REGULATION
Line1,3
VRLINE
V
P
V
P
IN = 16, 28, and 40 VDC
OUT = .5, 10, 20W (main)
IN = 16, 28, and 40 VDC(dual)
OUT = 0, 5, 10W (dual)12
mV
mV
mV
mV
25
60
50
60
25
75
50
75
±
±
±
±
±
±
±
±
Load1,3
VRLOAD
VIN = 16, 28, and 40 VDC
P
V
P
OUT = .5, 10, 20W (main)
IN = 16, 28, and 40 VDC
OUT = o, 5, 10W (dual)12
INPUT
Current
IIN
I
OUT = 0, inhibit (pin 8)
Tied to input return (pin 10)
15
75
15
75
mA
mA
I
I
OUT = 0, inhibit (pin 8) = open
OUT = 4000mA (main)
Ripple Current4
EFFICIENCY
IRIP
P
OUT = 10W (dual)12
BW = 20Hz to 2MHz
50
50
mAp-p
%
EFF
75
72
75
72
IOUT = 4000mA (main) +25 C
°
P
OUT = 10W (dual)12
over temp. range
Input to output or any pin to case
ISOLATION
ISO
PD
(except pin 8)at 500 TC=+25 C
°
100
100
M
Ω
Load Fault Power Dissipation3
Overload
14
9
14
9
W
W
Short circuit
Switching Frequency
SYNC Frequency Range
FS
FSYNC
500
500
600
700
500
500
600
700
KHz
KHz
50% load to/from 100% load
no load to/from 50% load
Inhibit Open Circuit Voltage
Output Response to
Step transient
VOI
9
13
9
13
V
mVpk
VOTLOAD
TTLOAD
50% load to/from 100% load
No load to/from 50% load
50% load to/from 100% load
No load to 50% load
-500
-1000
+500
+1000
200
5
-500
-1000
+500
Load changes7
+1000
200
5
Recovery Time Step
Step transient
s
µ
ms
ms
Load changes7,8
50% load to no load
10
10
For Notes to Specifications, refer to page 3
2
www.irf.com
ATR28XXT Series
Specifications
TCASE = -55°C to +125°C, VIN = +28V ± 5% unless otherwise specified
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Power Output
Soldering
-0.5V to 50VDC
Internally limited, 17.5W typical
300°C for 10 seconds
Operating
Storage
Temperature Range6
-55°C to +135°C case
-65°C to +135°C
Conditions
ATR2812T
ATR2815T
-55 C TC +125 C,
°
≤
≤
°
Test
Symbol
VIN = 28 V 5%, C =0,
±
unless otheDrwC ise speLcified
Min
Max
Min
Max
Units
STATIC CHARACTERISTICS
Output Response to
Transient step9
VOTLINE
TTLINE
Input step 16 from/to 40 VDC
IOUT = 4000mA (main)
mV pk
1500
10
1500
10
±
±
Line changes10
POUT = 10W (dual)
Recovery Time8
Transient step9
Line changes10
Input step 16 from/to 40 VDC
IOUT = 4000mA (main)
POUT = 10W (dual)
IOUT = 0, and 4000mA (main)
POUT = 0, 10W (dual)
ms
Turn on Overshoot1
VTonOS
TonD
1000
1000
mV pk
Turn on Delay 1, 11
IOUT = 0, 4000mA (main)
POUT = 0, 10W (dual)
25
25
25
25
ms
ms
Load Fault Recovery10
TRLF
Notes to Specifications
1. Tested at each output.
2. Parameter guaranteed byline and load regulation tests.
3. Although operation with no load is permissible, light loading on the main (+5 volt) output may cause the output voltage of the
auxiliary outputs (±12 volt or ±15 volt) to drop out of regulation. It is therefore recommended that at least 100mA or 20 percent of
the output power, whichever is greater, be taken from the main (+5 volt) output.
4. Total combined output power –30 watts.
5. Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
6. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the overload protection
circuit and is the condition of maximum power dissipation.
7. Load step transition time between 2 and 10 microseconds.
8. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50 percent
load.
9. Input step transition time between 2 to 10 microseconds.
10. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified in the table.
11. Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 8) while power is applied to the input.
www.irf.com
3
ATR28XXT Series
ATR28XXT Block Diagram
5
+Vout
EM I
Filter
Tracking
Regulator
1
+Input
4
2
-Vout
Prim ary
Housekeeping
Supply
8
+Vout
Enable
7
3
Return
Case
Drive
Error
Am p &
Ref
Pulse W idth
M odulator
9
FB
Sync
CS
Input
Return
10
4
www.irf.com
ATR28XXT Series
ATR28XXT Case Outline
1.000
0.05
0.040 D
X
0.26 L Pins
2.700
M ax
4 X 0.400
=1.600
2.360
1.95
0.410
M ax
1.350
M ax
Pin Designation
Part Numbering
ATR 28 15 T F / CH
Pin No.
Designation
Screening
Model
– , ES, HB, CH
1
2
Positive Input
+5VDC Output
Output Return
Input Voltage
Package Style
28 = 28V Nominal
F = Flange
Outputs
T = Triple
S = Single
D = Dual
Output Voltage
12 = 5V,±12V:
3
4
Negative Dual Output
15 = 5V,±12V:
5
Positive Dual Output
N/C
6
7
Case Ground
Enable Input
Sync Input
8
9
10
Input Return
www.irf.com
5
ATR28XXT Series
Available Screening Levels and ProcessVariations for ATR28XXT Series
Requirement
MIL-STD-883
Method
No
Suffix
ES
Suffix
HB
Suffix
CH
Suffix
Temperature
Range
-20 to +85°C
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
Element
MIL-PRF-38534
Evaluation
Internal Visual
Temperature
Cycle
2017
1010,
Cond C
Yes
Cond B
Yes
Yes
Yes
Yes
Constant
2001,
500g
5,000 g
5,000 g
Acceleration
Burn-in
Cond A
1015
48hrs @ 85°C
25°C
48hrs @ 125°C
25°C
160hrs @ 125°C
-55, +25, +125°C
160hrs @ 125°C
-55, +25, +125°C
Final Electrical
(Group A)
MIL-PRF-
38534
Seal, Fine &
Gross
External
Visual
1014
2009
Yes
Yes
Yes
Yes
Yes
Yes
* Per Commercial Standards
Available Standard Military Drawing (SMD) Cross Reference
Standardized
Military drawing
PIN
Vendor
CAGE
Code
Vendor
Similar
PIN
5962-9315801HXX
5962-9315801HZX
5962-9215901HXX
5962-9215901HZX
52467
52467
52467
52467
ATR2812T/CH
ATR2812TF/CH
ATR2815T/CH
ATR2815TF/CH
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331
ADVANCED ANALOG: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 10/02
6
www.irf.com
相关型号: