PD-97418
ATW28300S
(IR P/N 10207)
28V Input, 300V Single Output
HYBRID HIGH-RELIABILITY
DC-DC CONVERTER
Description
The ATW28300S DC-DC converter features high
power density and an extended temperature range
for use in military and industrial applications.
Designed to MIL-STD-704D input requirements, this
device operates with a nominal 28VDC input with an
adjustable output of 150 to 300V via external
potentiometer. The circuit design incorporates a pulse
width modulated push-pull topology operating in the
feed-forward mode at a nominal switching frequency
of 270KHz. Input to output isolation is achieved
through the use of transformers in the forward and
feedback circuits.
ATW
Features
n 18V to 40VDC Input Range (28VDC Nominal)
n Short Circuit and Overload Protected
n 22.8W/in3 Power Density
n 30W Output Power
n Adjustable Output Voltage
n Fast Loop Response
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than
devices incorporating optical feedback circuits.
n Superior Transient Characteristics
n Operating Temperature Range of
-55°C to +125°C
n Popular Industry Standard Pin-Out
n Resistance Seam Welded Case for Superior
Long Term Hermeticity
Manufactured in a facility fully qualified to MIL-PRF-
38534, this converter is available in four screening
grades to satisfy a wide range of requirements. The
CH grade is fully compliant to the requirements of
MIL-PRF-38534 for class H. The HB grade is
processed and screened to the class H requirement,
but may not necessarily meet all of the other MIL-
PRF-38534 requirements, e.g., element evaluation
and periodic inspection not required. Both grades
are tested to meet the complete group “A” test
specification over the full military temperature range
without output power deration. Two grades with more
limited screening are also available for use in less
demanding applications. For screening options, refer
to device screening table. Variations in electrical,
mechanical and screening can be accommodated.
Contact IR San Jose for special requirements.
n Shutdown from External Signal
n Full Military Screening
n
MIL-PRF-38534 Compliant
www.irf.com
1
12/14/10
ATW28300S (IR P/N 10207)
Specifications
Absolute Maximum Ratings
Input voltage
(-0.3V to +40VDC) Continuous, (-0.5V to +50VDC) Up to 1 second
Soldering temperature, Lead
Operating case temperature
Storage case temperature
300°C for 10 seconds
-55°C to +125°C
-65°C to +135°C
Electrical Performance Characteristics
Test
Symbol
Conditions
-55°C ≤Tc ≤+125°C
VIN= 28VDC ±5%, CL = 0
RADJ = 455 Ohms
Group A
Subgroups
Limits
Unit
Unless otherwise specified
VIN = 18, 28, and 40VDC
Min
130
Max
145
Output voltage Min 10
Output voltage Max 10
VOUT
Min
VOUT
1,2,3
1,2,3
VDC
VDC
IOUT = 5.0mA, RADJ = 30 Ohms
VIN = 18, 28, and 40VDC
305
5.0
320
Max
IOUT = 5.0mA, RADJ = 940 Ohms
IOUT = 100mA up to 1000 hrs
VIN = 18, 28, and 40VDC
Output voltage stability
Output current 8
1,2,3
1,2,3
2.0
100
%
mADC
IOUT
VRIP
7
VIN = 18, 28, and 40VDC,
Iout = 50mA,
Output ripple voltage
1,2,3
1000
mVp-p
Iout = 100mA,
B.W. = DC to 1.0MHz
VIN = 18, 28, 40VDC.
RADJ = 940 Ohms
VIN = 18, 28, and 40VDC,
Output power 4, 8
Line regulation
POUT
VRLINE
VRLOAD
IIN
1,2,3
1,2,3
1,2,3
1,2,3
30
W
%
1.0
1000
18
I
OUT = 5.0, 50, and 100mA
VIN = 18, 28, and 40VDC,
OUT = 5.0, 50, and 100mA
Load regulation
Input current
mV
I
IOUT = 0, Enable (pin 2) tied to
Input Return
mADC
IOUT = 0, Enable (pin2) = open
IOUT = 100mA
IOUT = 100mA,
1,2,3
1,2,3
1
80
50
mADC
mAp-p
%
Input ripple current
Efficiency
IRIP
EFF
80
78
RADJ = 940 Ohms
2,3
Isolation
ISO
Input to output or any pin
to case (except pin 2) at 500VDC,
Tc = 25°C
No effect on DC performance
Overload 3
1
100
MΩ
6, 9
CL
PD
4
1
10
14
µF
W
Capacitive load
Power dissipation
load fault
Short circuit
IOUT = 100mA
VOTLOAD 50mA load to/from100mA load
1
9.0
300
+3.0
W
KHz
Vpk
Switching frequency
FS
1,2,3
4,5,6
250
-3.0
Output response to step
transient load changes 5
5.0mA load to/from100mA load
4,5,6
4,5,6
-10
+10
2.0
Vpk
ms
Recovery time step
TTLOAD
50mA load to/from100mA load
5.0mA load to/from100mA load
transient load changes1, 5
4,5,6
5.0
ms
For Notes to Specifications, refer to page 3
2
www.irf.com
ATW28300S (IR P/N 10207)
Electrical Performance Characteristics - continued
Test
Symbol
Conditions
Group A
Limits
Unit
Subgroups
-55°C ≤Tc ≤+125°C
IN = 28VDC ±5%, CL = 0
V
RADJ = 455 Ohms
Unless otherwise specified
Min
-10
Max
+10
Output response
transient step line
changes 5, 9
Recovery time
transient step line
changes 1, 5, 9
VOTLINE
TTLINE
Input step 18 to/from 40VDC
4,5,6
4,5,6
Vpk
ms
Input step 18 to/from 40VDC
IOUT = 0 and 100mA,
ADJ = 940 Ohms
IOUT = 0 and 100mA,
ADJ = 940 Ohms
VIN = 18 to 40VDC,
ADJ = 940 Ohms
Flange
2.0
Turn on overshoot
VTonOS
TonD
TrLF
4,5,6
4,5,6
4,5,6
20
350
350
75
Vpk
ms
ms
g
R
Turn on delay 2
R
Load fault recovery 9
Weight
R
Notes to Specifications
1
2
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.
Turn-on delay time measurement is for either a step application of power at the input or the removal of ground signal from the
Enable pin (pin 2) while power is applied to the input.
3
An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit
protection and is a condition of maximum power dissipation.
4
5
6
Above +125°C case, derate output power linearly to 0 to +135°C case.
Transition time >10µs.
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess
of the maximum limit may disturb loop stability and may interfere with the operation of the load fault detection circuitry, appearing
as an overload during turn-on.
7
8
9
Bandwidth guaranteed by design. Tested for 20KHz to 1.0MHz.
Parameter guaranteed by line and load regulation tests.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be
guaranteed to the limits specified in this table.
10 Output voltage can be adjusted to the range of 150V to 300V with an external 1KOhms trim pot. The trim pot shall be connected
to pin 5 (Output Adjust 1) and pin 6 (Output Adjust 2).
www.irf.com
3
ATW28300S (IR P/N 10207)
Block Diagram
3
+Output
Input
Filter
Input
1
2
Output
Return
Drive 1
Drive 2
4
Enable
Pulse Width
Modulator
Output
Adjust 1
Error Amp
& Reference
Feedback
5
6
Output
Adjust 2
Input
Return
10
Mechanical Outline
1.000
0.05
0.040 D X
0.26 L Pins
2.700
Max
4 X 0.400
=1.600
2.360
1.95
0.500
Max
1.350
Max
Notes:
1) All dimensions are in inches
2) The tolerance for X.XXX = ±0.005
Pin Designation
Pin #
Designation
Pin #
Designation
1
2
3
4
5
+Input
Enable
+ Output
6
7
8
9
10
Output Adjust 2
Case
N/C
N/C
Input Return
Output Return
Output Adjust 1
4
www.irf.com
ATW28300S (IR P/N 10207)
Device Screening
Requirement
MIL-STD-883 Method No Suffix
ES
HB
CH
Temperature Range
Element Evaluation
Non-Destructive
Bond Pull
-20°C to +85°C -55°C to +125°C -55°C to +125°C -55°C to +125°C
MIL-PRF-38534
2023
N/A
N/A
N/A
N/A
N/A
N/A
Class H
N/A
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
2017
1010
Yes
Cond B
500 Gs
N/A
Yes
Cond C
3000 Gs
N/A
Yes
Cond C
3000 Gs
N/A
N/A
N/A
2001, Y1 Axis
2020
N/A
Burn-In
1015
N/A
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
25°C
25°C
-55°C, +25°C,
+125°C
N/A
-55°C, +25°C,
+125°C
10%
PDA
N/A
Cond A
N/A
N/A
Cond A, C
N/A
Seal, Fine and Gross
Radiographic
External Visual
Cond A, C
N/A
Cond A, C
N/A
2012
2009
Yes
Yes
Yes
Notes:
Best commercial practice
Sample tests at low and high temperatures
Part Definition
Part Numbering
IR P/N 10207EM = ATW28300S/ES
IR P/N 10207FM = ATW28300S/HB
ATW 28 300 S /CH
Model
Screening Level
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Input Voltage
Nominal
28 = 28V
Output
S = Single
Output Voltage
300 = 300V
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SAN JOSE: 2520Junction Avenue, San Jose, California 95134, Tel: (408) 434-5000
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 12/2010
www.irf.com
5
相关型号:
©2020 ICPDF网 联系我们和版权申明