TECHNICAL DATA  
BUS INTERFACE MODUL  
BIM M111, BIM M115  
d6  
d1  
c6  
c1  
b6  
b1  
a6  
a1  
Features  
· EIB Bus Interface Module for piggyback-use  
on PCBs  
e2  
e1  
· MC68HC05B6 with mask programmed ROM,  
contains the EIB System Software  
· PEI *) and Port A, PLM A and PLM B for  
applications available  
· Smallest instabus EIB Bus Access Unit  
· Operating Temperature Range:  
BIM M111: - 5 to + 45 °C  
Ordering Information  
BIM M111  
BIM M115: - 25 to + 70 °C  
5WG1 111 8AA01  
BIM M115  
· EIBA certified part  
*) = Peripheral External Interface  
5WG1 115 8AA01  
DESCRIPTION  
The BIM M111 or the BIM M115 are members of Siemens instabus EIB BCU - family. They are  
especially designed as small modules for piggyback use and can be fitted directly into PCBs. The  
modules contain all functional parts of a EIB - BCU with the exception of shift register for the serial  
synchronous interface. Additionally access to such microcontroller ports as Reset, PLMA, or Port A  
is possible. These ports are directly accessible by the user. Additional pins for the connection of an  
external programming button and a LED are available. For applications with the need of longer 'Bus  
Buffer Time' the BIM allows to connect an additional capacitance at bus voltage level.  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 1  
© Siemens AG 2000  
BIM M111 / M115  
Schematic Block Diagram  
PEI  
Port A  
PLMA  
PLMB  
Reset  
EIB  
BIM M111,  
BIM M115  
Programming  
Buffer Time  
LED  
Button  
Absolute Maximum Electrical Ratings  
Rating  
Symbol  
Value  
Units  
Bus Voltage  
V Bus  
V...  
V
± 35  
Microcontroller Input Voltage PEI,  
PLMA, PLMB, Reset, LED, Button  
Microcontroller input or output current  
per Pin  
GND - 0,5 to Vcc + 0,5  
V
I
see Motorola Technical  
Data MC68HC05B6  
Features of the Controller  
· CPU  
MC68HC05B6  
· Operating Frequency  
· On-Chip RAM  
· On-Chip EEPROM  
2,0 MHz (crystal frequency of 4,0 MHz)  
176 Bytes ( 18 Bytes available for user )  
256 Bytes (230 Bytes available for user)  
· 8-Bit A/D-converter (5 channels available for user)  
· 8-Bit pulse length modulator (PLM)  
· Serial asynchronous communication interface  
· Serial synchronous communication interface  
· Watch dog  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 2  
© Siemens AG 2000  
BIM M111 / M115  
HARDWARE BLOCK DIAGRAM  
BIM M 111  
BIM M 115  
PA0  
PA1  
PA2  
PA3  
PA4  
PA5  
b5  
0
7
a6  
b4  
a5  
Port A  
Port B  
b3  
a4  
PA6  
PA7  
b2  
TRANSFORMER-  
MODULE  
a3  
+5V  
Programming  
47k  
BUTTON  
LED  
2
7
c2  
c6  
+
e1  
+5V  
BUS  
e2  
PLMA  
PLMB  
PLMA  
PLMB  
b1  
d6  
-
TxD  
d3  
d4  
c3  
d5  
c4  
b6  
RxD  
CLK  
RTS  
CTS  
PC7  
PEI-  
Signal-  
Pins 1)  
TYPE  
Port D 4  
c5  
+5V  
RType  
47k5  
+5V  
3)  
VCC  
VDD  
d2  
d1  
c1  
+20V  
GND  
+5V  
+5V  
Note: Use the C35V-pin only for extension of "Bus  
Buffer Time". Do not draw current! Otherwise  
the quality of bus transmission would be  
affected.  
a2  
2)  
a1  
1)  
2)  
3)  
For detailed description see "PEI" - table.  
Additional capacitance (Vc=35V) for extended "Bus Buffer Time", e.g.100mF.  
Additional capacitance (Vc=5V) for extended "Bus Buffer Time"., e.g. 470mF.  
Memory Map  
Address Range  
Memory  
Bytes  
32  
0000  
0020  
0050  
00C0  
0100  
0101  
0120  
0200  
1FF2  
001F  
004F  
00BF  
00FF  
0100  
011F  
01FF  
1FF1  
1FFF  
I/O, Register  
ROM  
48  
RAM  
176  
64  
Stack  
OPTR  
1
EEPROM non protected  
EEPROM protected  
ROM and unused areas  
Special functions  
31  
224  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 3  
© Siemens AG 2000  
BIM M111 / M115  
PEI (Physical External Interface)  
PEI – Pin – Assignment  
Serial  
I - Ports  
or A / D –  
Ports  
Pin  
Power  
Digital I /O  
- Ports  
Remarks  
Interface  
Mnemonics  
Supply  
Async./sync.  
a1 RESET  
_RESET  
In-/Output  
a2 C35V  
a3 PA7  
a4 PA5  
a5 PA3  
a6 PA1  
b1 PLMA  
b2 PA6  
b3 PA4  
b4 PA2  
b5 PA0  
b6 PC7  
Buffer Capacitor  
PA7  
PA5  
PA3  
PA1  
PLMB  
PA6  
PA4  
PA2  
PA0  
PC7  
Digital Input / Output  
Digital Input / Output  
Digital Input / Output  
Digital Input / Output  
Pulse-Length-Mod.  
Digital Input / Output  
Digital Input / Output  
Digital Input / Output  
Digital Input / Output  
Digital Output (Input /  
Output when PEI-Type17)  
c1 GND  
c2 BUTTON  
c3 CLK  
Ground  
PB2  
PC4  
PC6  
Digital Input  
SCLK  
PD6  
PD3  
PD4  
Clock ·®  
c4 CTS  
c5 TYPE  
c6 LED  
Clear to Send ·¬  
PEI - Type  
PB7  
Digital Output  
2mA Current Limit.  
d1 VDD  
Vdd  
(20V)  
d2 VCC  
d3 TxD  
d4 RxD  
d5 RTS  
d6 PLMB  
e1 + Bus  
e2 - Bus  
Vcc (5V)  
TDO  
RDI  
PD5  
PD7  
PD2  
PC3  
PC2  
PC5  
PLMB  
Data ·®  
Data ·¬  
Request to Send ·®  
Pulse-Length-Mod.  
Bus Line  
Bus Line  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 4  
© Siemens AG 2000  
BIM M111 / M115  
ELECTRICAL SPECIFICATION  
See also EIBA Handbook for Development, Release 3.0  
Bus Interface Characteristics:  
Characteristics  
Symbol  
Min  
21  
Max  
30  
Typical  
Unit  
Remarks  
Operating Voltage  
V
I
V
Bus  
Current consumption  
Reset conditions  
4
mA  
V
Bus  
Vcc  
< 4,6  
TBD  
Reset generated by  
transceiver  
BCU-Buffer-Time  
Transmission Rate  
ms  
PEI-Load:50mW  
9600  
bit/s  
PEI DC-Characteristics:  
Characteristics  
Supply Output  
Voltage +5V  
Supply Output  
Voltage +20V  
Symbol  
VCC  
Min  
Max  
5.3  
Typical  
Unit  
Remarks  
Max. 10mA  
4.7  
18  
V
V
VDD  
20.5  
load = 2mA  
VBUS - VDD  
> 1,5V  
VBUS = 21V  
... 30V  
Current Limitation  
Data Output Voltage  
Port A, Port B, Port C  
Data Output Voltage  
TDO, SCLK, PLMB  
Data Output Voltage  
Reset  
Data Input Voltage  
Port A, Port B, Port C  
Reset, RDI  
IDD  
2
5
0.4  
mA  
V
VOL  
VOH  
VOL  
VOH  
VOL  
Iload=1,6mA  
Iload=0,8mA  
Iload=1,6mA  
Iload=1,6mA  
Iload=1,6mA  
VCC-0,8  
VCC-0,8  
0.4  
1,0  
V
V
V
VIL  
VIH  
0
0.2 VCC  
VCC  
0.7 VCC  
Analog Input Voltage  
Range  
I/O Ports Three-State-  
Leakage  
VAIL  
VAIH  
IOZ  
0
V
VCC  
±10  
mA  
pF  
Input Capacitance  
CIN  
50  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 5  
© Siemens AG 2000  
BIM M111 / M115  
Timing  
The timing of Save, Reset, VCC and VDD which are depending on VBUS are shown in the following  
depiction:  
+21V to 30V  
min. 16V  
max. 19.5V  
VBUS  
0V  
+5V  
min 4.6V  
VCC  
0V  
+5V  
0V  
SAVE  
+5V  
RESET  
0V  
+20V  
resistive load  
VDD  
VDD  
0V  
+20V  
capacitive load  
0V  
Environmental Conditions  
Rating  
Symbol  
Value  
Unit  
Remarks  
Operation Temperature Range BIM M111  
Operation Temperature Range BIM M115  
Storage Temperature Range BIM M111  
Storage Temperature Range BIM M115  
Relative Humidity  
TA  
- 5 to + 45 °C  
- 25 to + 70 °C  
- 25 to + 55 °C  
-25 to + 70 °C  
no condensation  
no condensation  
TA  
TSTG  
TSTG  
5 to 93  
%
no condensation  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 6  
© Siemens AG 2000  
BIM M111 / M115  
SOFTWARE SPECIFICATION  
See also EIBA Handbook for Development, Release 3.0  
Application Hint  
To avoid malfunctioning by EMI, it is recommended to shield the BIM. The connection for the  
electric screen is shown in the figure below.  
BIM  
Connection for electric screen (= Ground),  
for information about the exact position see "Maßbild"  
The data contained herein are subject to change without notice. Siemens does not warrant  
for correctness or completeness of the documentation or that the products described are  
qualified for certification.  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights,  
including right created by patent grant or registration of a utility model or design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 7  
© Siemens AG 2000  
BIM M111 / M115  
MECHANICAL SPECIFICATION (BIM M111)  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights, including right created by patent grant or registration of a utility model or  
design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 8  
© Siemens AG 2000  
BIM M111 / M115  
MECHANICAL SPECIFICATION (BIM M115)  
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written approval. All rights, including right created by patent grant or registration of a utility model or  
design, are reserved. Technical changes reserved.  
25 15 14.41.03a  
31.10.00  
page 9  
© Siemens AG 2000  

相关型号:

BIMM115

BUS INTERFACE MODUL
INFINEON

BIMRETEX551

GEHAEUSE 1X9V PP3 ODER 2XAA 28X105X61
ETC

BIMRETEX552

GEHAEUSE 1X9V PP3 ODER 2XAA 34X145X80
ETC

BIO-ST01-C4M1-A10-01

HDMI Up to 3840 x 2160 (4K) Resolution
AAEON

BIO-ST01-L1U2

support pico-bt01 bio daughter board option
AAEON

BIO-ST01-L1U2-A10-01

HDMI Up to 3840 x 2160 (4K) Resolution
AAEON

BIO-ST01-M1U1

support pico-bt01 bio daughter board
AAEON

BIO-ST01-M1U1-A10-01

HDMI Up to 3840 x 2160 (4K) Resolution
AAEON

BIO-ST02-C4M1

support pico-bt01 bio daughter board option
AAEON

BIO-ST02-C4M1-A10-01

support pico-bt01 bio daughter board option
AAEON

BIR-BL0331

INFRARED EMITTING DIODES
ETC

BIR-BL03J4G

INFRARED EMITTING DIODES
ETC