Data Sheet  
Programmable logic device (PLD) manufactured using a 0.15-µm all-  
Features...  
layer copper-metal fabrication process  
25 to 35% faster design performance than APEXTM 20KE devices  
Pin-compatible with APEX 20KE devices  
High-performance, low-power copper interconnect  
MultiCoreTM architecture integrating look-up table (LUT) logic  
and embedded memory  
LUT logic used for register-intensive functions  
Embedded system blocks (ESBs) used to implement memory  
functions, including first-in first-out (FIFO) buffers, dual-port  
RAM, and content-addressable memory (CAM)  
High-density architecture  
200,000 to 1 million typical gates (see Table 1)  
Up to 38,400 logic elements (LEs)  
Up to 327,680 RAM bits that can be used without reducing  
available logic  
Table 1. APEX 20KC Device Features  
Note (1)  
Feature  
EP20K200C  
EP20K400C  
EP20K600C  
EP20K1000C  
Maximum system gates  
Typical gates  
526,000  
200,000  
8,320  
52  
1,052,000  
400,000  
16,640  
104  
1,537,000  
600,000  
24,320  
152  
1,772,000  
1,000,000  
38,400  
160  
LEs  
ESBs  
Maximum RAM bits  
PLLs (2)  
106,496  
2
212,992  
4
311,296  
4
327,680  
4
Speed grades (3)  
Maximum macrocells  
Maximum user I/O pins  
-7, -8, -9  
832  
-7, -8, -9  
1,664  
-7, -8, -9  
2,432  
-7, -8, -9  
2,560  
376  
488  
588  
708  
Notes to Table 1:  
(1) The embedded IEEE Std. 1149.1 Joint Test Action Group (JTAG) boundary-scan circuitry contributes up to  
57,000 additional gates.  
(2) PLL: phase-locked loop.  
(3) The -7 speed grade provides the fastest performance.  
Altera Corporation  
1
DS-APEX20KC-2.2  
APEX 20KC Programmable Logic Device Data Sheet  
Low-power operation design  
...and More  
Features  
1.8-V supply voltage (see Table 2)  
Copper interconnect reduces power consumption  
MultiVoltTM I/O support for 1.8-V, 2.5-V, and 3.3-V interfaces  
ESBs offering programmable power-saving mode  
Flexible clock management circuitry with up to four phase-locked  
loops (PLLs)  
Built-in low-skew clock tree  
Up to eight global clock signals  
ClockLockTM feature reducing clock delay and skew  
ClockBoostTM feature providing clock multiplication and  
division  
ClockShiftTM feature providing programmable clock phase and  
delay shifting  
Powerful I/O features  
Compliant with peripheral component interconnect Special  
Interest Group (PCI SIG) PCI Local Bus Specification,  
Revision 2.2 for 3.3-V operation at 33 or 66 MHz and 32 or 64 bits  
Support for high-speed external memories, including DDR  
synchronous dynamic RAM (SDRAM) and ZBT static RAM  
(SRAM)  
16 input and 16 output LVDS channels at 840 megabits per  
second (Mbps)  
Direct connection from I/O pins to local interconnect providing  
fast tCO and tSU times for complex logic  
MultiVolt I/O support for 1.8-V, 2.5-V, and 3.3-V interfaces  
Programmable clamp to VCCIO  
Individual tri-state output enable control for each pin  
Programmable output slew-rate control to reduce switching  
noise  
Support for advanced I/O standards, including low-voltage  
differential signaling (LVDS), LVPECL, PCI-X, AGP, CTT,  
SSTL-3 and SSTL-2, GTL+, and HSTL Class I  
Supports hot-socketing operation  
Pull-up on I/O pins before and during configuration  
Table 2. APEX 20KC Supply Voltages  
Feature  
Voltage  
Internal supply voltage (VCCINT  
)
1.8 V  
MultiVolt I/O interface voltage levels (VCCIO) 1.8 V, 2.5 V, 3.3 V, 5.0 V (1)  
Note to Table 2:  
(1) APEX 20KC devices can be 5.0-V tolerant by using an external resistor.  
2
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Advanced interconnect structure  
Copper interconnect for high performance  
Four-level hierarchical FastTrack® interconnect structure  
providing fast, predictable interconnect delays  
Dedicated carry chain that implements arithmetic functions such  
as fast adders, counters, and comparators (automatically used by  
software tools and megafunctions)  
Dedicated cascade chain that implements high-speed,  
high-fan-in logic functions (automatically used by software tools  
and megafunctions)  
Interleaved local interconnect allows one LE to drive 29 other  
LEs through the fast local interconnect  
Advanced software support  
Software design support and automatic place-and-route  
provided by the Altera® QuartusTM II development system for  
Windows-based PCs, Sun SPARCstations, and HP 9000  
Series 700/800 workstations  
Altera MegaCore® functions and Altera Megafunction Partners  
Program (AMPPSM) megafunctions optimized for APEX 20KC  
architecture available  
NativeLinkTM integration with popular synthesis, simulation,  
and timing analysis tools  
Quartus II SignalTap® embedded logic analyzer simplifies  
in-system design evaluation by giving access to internal nodes  
during device operation  
Supports popular revision-control software packages including  
PVCS, RCS, and SCCS  
Table 3. APEX 20KC QFP & BGA Package Options & I/O Count Notes (1), (2)  
Device  
208-Pin PQFP 240-Pin PQFP 356-Pin BGA 652-Pin BGA  
EP20K200C  
EP20K400C  
EP20K600C  
EP20K1000C  
136  
168  
271  
488  
488  
488  
Altera Corporation  
3
APEX 20KC Programmable Logic Device Data Sheet  
Table 4. APEX 20KC FineLine BGA Package Options & I/O Count Notes (1), (2)  
Device  
484 Pin  
672 Pin  
1,020 Pin  
EP20K200C  
EP20K400C  
EP20K600C  
EP20K1000C  
376  
488 (3)  
508 (3)  
508 (3)  
588  
708  
Notes to Tables 3 and 4:  
(1) I/O counts include dedicated input and clock pins.  
(2) APEX 20KC device package types include plastic quad flat pack (PQFP), 1.27-mm  
pitch ball-grid array (BGA), and 1.00-mm pitch FineLine BGATM packages.  
(3) This device uses a thermally enhanced package, which is taller than the regular  
package. Consult the Altera Device Package Information Data Sheet for detailed  
package size information.  
Table 5. APEX 20KC QFP & BGA Package Sizes  
Feature  
208-Pin PQFP  
240-Pin PQFP  
356-Pin BGA  
652-Pin BGA  
Pitch (mm)  
Area (mm2)  
0.50  
924  
0.50  
1,218  
1.27  
1,225  
1.27  
2,025  
Length × Width (mm × mm)  
30.4 × 30.4  
34.9 × 34.9  
35.0 × 35.0  
45.0 × 45.0  
Table 6. APEX 20KC FineLine BGA Package Sizes  
Feature  
484 Pin  
672 Pin  
1,020 Pin  
Pitch (mm)  
Area (mm2)  
1.00  
529  
1.00  
729  
1.00  
1,089  
Length × Width (mm × mm)  
23 × 23  
27 × 27  
33 × 33  
Similar to APEX 20K and APEX 20KE devices, APEX 20KC devices offer  
the MultiCore architecture, which combines the strengths of LUT-based  
and product-term-based devices with an enhanced memory structure.  
LUT-based logic provides optimized performance and efficiency for data-  
path, register-intensive, mathematical, or digital signal processing (DSP)  
designs. Product-term-based logic is optimized for complex  
General  
Description  
combinatorial paths, such as complex state machines. LUT- and product-  
term-based logic combined with memory functions and a wide variety of  
MegaCore and AMPP functions make the APEX 20KC architecture  
uniquely suited for SOPC designs. Applications historically requiring a  
combination of LUT-, product-term-, and memory-based devices can now  
be integrated into one APEX 20KC device.  
4
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
APEX 20KC devices include additional features such as enhanced I/O  
standard support, CAM, additional global clocks, and enhanced  
ClockLock clock circuitry. Table 7 shows the features included in  
APEX 20KC devices.  
Table 7. APEX 20KC Device Features (Part 1 of 2)  
Feature  
APEX 20KC Devices  
MultiCore system integration  
Hot-socketing support  
Full support  
Full support  
Full support  
SignalTap logic analysis  
32-/64-bit, 33-MHz PCI  
32-/64-bit, 66-MHz PCI  
Full compliance  
Full compliance in -7 and -8 speed grades in  
selected devices  
MultiVolt I/O  
1.8-V, 2.5-V, or 3.3-V VCCIO  
VCCIO selected bank by bank  
5.0-V tolerant with use of external resistor  
ClockLock support  
Clock delay reduction  
m/(n × v) clock multiplication  
Drive ClockLock output off-chip  
External clock feedback  
ClockShift circuitry  
LVDS support  
Up to four PLLs  
ClockShift clock phase adjustment  
Dedicated clock and input pins  
Eight  
Altera Corporation  
5
APEX 20KC Programmable Logic Device Data Sheet  
Table 7. APEX 20KC Device Features (Part 2 of 2)  
Feature  
APEX 20KC Devices  
I/O standard support  
1.8-V, 2.5-V, 3.3-V, 5.0-V I/O  
3.3-V PCI and PCI-X  
3.3-V AGP  
CTT  
GTL+  
LVCMOS  
LVTTL  
True-LVDSTM and LVPECL data pins (in  
EP20K400C and larger devices)  
LVDS and LVPECL clock pins (in all devices)  
LVDS and LVPECL data pins up to 156 Mbps  
(in EP20K200C devices)  
HSTL Class I  
PCI-X  
SSTL-2 Class I and II  
SSTL-3 Class I and II  
Memory support  
CAM  
Dual-port RAM  
FIFO  
RAM  
ROM  
All APEX 20KC devices are reconfigurable and are 100% tested prior to  
shipment. As a result, test vectors do not have to be generated for fault-  
coverage purposes. Instead, the designer can focus on simulation and  
design verification. In addition, the designer does not need to manage  
inventories of different application-specific integrated circuit (ASIC)  
designs; APEX 20KC devices can be configured on the board for the  
specific functionality required.  
APEX 20KC devices are configured at system power-up with data stored  
in an Altera serial configuration device or provided by a system  
controller. Altera offers in-system programmability (ISP)-capable EPC16,  
EPC8, EPC4, EPC2, and EPC1 configuration devices and one-time  
programmable (OTP) EPC1 configuration devices, which configure  
APEX 20KC devices via a serial data stream. Moreover, APEX 20KC  
devices contain an optimized interface that permits microprocessors to  
configure APEX 20KC devices serially or in parallel, and synchronously  
or asynchronously. The interface also enables microprocessors to treat  
APEX 20KC devices as memory and configure the device by writing to a  
virtual memory location, making reconfiguration easy.  
6
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
After an APEX 20KC device has been configured, it can be reconfigured  
in-circuit by resetting the device and loading new data. Real-time changes  
can be made during system operation, enabling innovative reconfigurable  
computing applications.  
APEX 20KC devices are supported by the Altera Quartus II development  
system, a single, integrated package that offers HDL and schematic design  
entry, compilation and logic synthesis, full simulation and worst-case  
timing analysis, SignalTap logic analysis, and device configuration. The  
Quartus II software runs on Windows-based PCs, Sun SPARCstations,  
and HP 9000 Series 700/800 workstations.  
The Quartus II software provides NativeLink interfaces to other industry-  
standard PC- and UNIX workstation-based EDA tools. For example,  
designers can invoke the Quartus II software from within third-party  
design tools. Further, the Quartus II software contains built-in optimized  
synthesis libraries; synthesis tools can use these libraries to optimize  
designs for APEX 20KC devices. For example, the Synopsys Design  
Compiler library, supplied with the Quartus II development system,  
includes DesignWare functions optimized for the APEX 20KC  
architecture.  
APEX 20KC devices incorporate LUT-based logic, product-term-based  
logic, and memory into one device on an all-copper technology process.  
Signal interconnections within APEX 20KC devices (as well as to and from  
device pins) are provided by the FastTrack interconnect—a series of fast,  
continuous row and column channels that run the entire length and width  
of the device.  
Functional  
Description  
Each I/O pin is fed by an I/O element (IOE) located at the end of each row  
and column of the FastTrack interconnect. Each IOE contains a  
bidirectional I/O buffer and a register that can be used as either an input  
or output register to feed input, output, or bidirectional signals. When  
used with a dedicated clock pin, these registers provide exceptional  
performance. IOEs provide a variety of features, such as 3.3-V, 64-bit,  
66-MHz PCI compliance; JTAG BST support; slew-rate control; and  
tri-state buffers. APEX 20KC devices offer enhanced I/O support,  
including support for 1.8-V I/O, 2.5-V I/O, LVCMOS, LVTTL, LVPECL,  
3.3-V PCI, PCI-X, LVDS, GTL+, SSTL-2, SSTL-3, HSTL, CTT, and 3.3-V  
AGP I/O standards.  
Altera Corporation  
7
APEX 20KC Programmable Logic Device Data Sheet  
The ESB can implement a variety of memory functions, including CAM,  
RAM, dual-port RAM, ROM, and FIFO functions. Embedding the  
memory directly into the die improves performance and reduces die area  
compared to distributed-RAM implementations. Moreover, the  
abundance of cascadable ESBs allows APEX 20KC devices to implement  
multiple wide memory blocks for high-density designs. The ESB’s high  
speed ensures it can implement small memory blocks without any speed  
penalty. Additionally, designers can use the ESBs to create as many  
different-sized memory blocks as the system requires. Figure 1 shows an  
overview of the APEX 20KC device.  
Figure 1. APEX 20KC Device Block Diagram  
Clock Management Circuitry  
FastTrack  
Interconnect  
IOE  
IOE  
ClockLock  
IOE  
LUT  
IOE  
LUT  
LUT  
IOE  
Four-input LUT  
for data path and  
DSP functions.  
LUT  
LUT  
IOE  
Product Term  
Memory  
Product Term  
Memory  
Product Term  
Memory  
Product Term  
Memory  
IOEs support  
PCI, GTL+,  
SSTL-3, LVDS,  
and other  
Product-term  
integration for  
high-speed  
control logic and  
state machines.  
standards.  
LUT  
LUT  
LUT  
Product Term  
Memory  
LUT  
Product Term  
Memory  
Product Term  
Memory  
IOE  
IOE  
Product Term  
Memory  
Flexible integration  
of embedded  
memory, including  
CAM, RAM,  
IOE  
IOE  
IOE  
IOE  
ROM, FIFO, and  
other memory  
functions.  
APEX 20KC devices provide four dedicated clock pins and four dedicated  
input pins that drive register control inputs. These signals ensure efficient  
distribution of high-speed, low-skew control signals, which use dedicated  
routing channels to provide short delays and low skews. Four of the  
dedicated inputs drive four global signals. These four global signals can  
also be driven by internal logic, providing an ideal solution for a clock  
divider or internally generated asynchronous clear signals with high  
fan-out. The dedicated clock pins featured on the APEX 20KC devices can  
also feed logic. The devices also feature ClockLock and ClockBoost clock  
management circuitry.  
8
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
MegaLAB Structure  
APEX 20KC devices are constructed from a series of MegaLABTM  
structures. Each MegaLAB structure contains 16 logic array blocks (LABs),  
one ESB, and a MegaLAB interconnect, which routes signals within the  
MegaLAB structure. In EP20K1000C devices, MegaLAB structures  
contain 24 LABs. Signals are routed between MegaLAB structures and  
I/O pins via the FastTrack interconnect. In addition, edge LABs can be  
driven by I/O pins through the local interconnect. Figure 2 shows the  
MegaLAB structure.  
Figure 2. MegaLAB Structure  
MegaLAB Interconnect  
LE1  
LE2  
LE3  
LE4  
LE5  
LE6  
LE7  
LE8  
LE9  
LE10  
LE1  
LE2  
LE3  
LE4  
LE5  
LE6  
LE7  
LE8  
LE9  
LE10  
LE1  
LE2  
LE3  
LE4  
LE5  
LE6  
LE7  
To Adjacent  
LAB or IOEs  
ESB  
LE8  
LE9  
LE10  
Local  
Interconnect  
LABs  
Logic Array Block  
Each LAB consists of 10 LEs, the LEs’ associated carry and cascade chains,  
LAB control signals, and the local interconnect. The local interconnect  
transfers signals between LEs in the same or adjacent LABs, IOEs, or ESBs.  
The Quartus II Compiler places associated logic within an LAB or adjacent  
LABs, allowing the use of a fast local interconnect for high performance.  
Figure 3 shows the APEX 20KC LAB.  
APEX 20KC devices use an interleaved LAB structure. This structure  
allows each LE to drive two local interconnect areas, minimizing the use  
of the MegaLAB and FastTrack interconnect and providing higher  
performance and flexibility. Each LE can drive 29 other LEs through the  
fast local interconnect.  
Altera Corporation  
9
APEX 20KC Programmable Logic Device Data Sheet  
Figure 3. LAB Structure  
Row  
Interconnect  
MegaLAB Interconnect  
LEs drive local,  
MegaLAB, row,  
and column  
interconnects.  
To/From  
To/From  
Adjacent LAB,  
ESB, or IOEs  
Adjacent LAB,  
ESB, or IOEs  
Column  
Interconnect  
Local Interconnect  
The 10 LEs in the LAB are driven by  
two local interconnect areas. These LEs  
can drive two local interconnect areas.  
Each LAB contains dedicated logic for driving control signals to its LEs  
and ESBs. The control signals include clock, clock enable, asynchronous  
clear, asynchronous preset, asynchronous load, synchronous clear, and  
synchronous load signals. A maximum of six control signals can be used  
at a time. Although synchronous load and clear signals are generally used  
when implementing counters, they can also be used with other functions.  
Each LAB can use two clocks and two clock enable signals. Each LAB’s  
clock and clock enable signals are linked (e.g., any LE in a particular LAB  
using CLK1will also use CLKENA1). LEs with the same clock but different  
clock enable signals either use both clock signals in one LAB or are placed  
into separate LABs.  
If both the rising and falling edges of a clock are used in a LAB, both LAB-  
wide clock signals are used.  
10  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The LAB-wide control signals can be generated from the LAB local  
interconnect, global signals, and dedicated clock pins. The inherent low  
skew of the FastTrack interconnect enables it to be used for clock  
distribution. Figure 4 shows the LAB control signal generation circuit.  
Figure 4. LAB Control Signal Generation  
4
Dedicated  
Clocks  
4
Global  
Signals  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
LABCLKENA1  
SYNCLOAD  
LABCLR1 (1)  
or LABCLKENA2  
SYNCCLR  
or LABCLK2 (2)  
LABCLK1  
LABCLR2 (1)  
Notes to Figure 4:  
(1) The LABCLR1and LABCLR2signals also control asynchronous load and asynchronous preset for LEs within the  
LAB.  
(2) The SYNCCLRsignal can be generated by the local interconnect or global signals.  
Logic Element  
The LE, the smallest unit of logic in the APEX 20KC architecture, is  
compact and provides efficient logic usage. Each LE contains a four-input  
LUT, which is a function generator that can quickly implement any  
function of four variables. In addition, each LE contains a programmable  
register and carry and cascade chains. Each LE drives the local  
interconnect, MegaLAB interconnect, and FastTrack interconnect routing  
structures. See Figure 5.  
Altera Corporation  
11  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 5. APEX 20KC Logic Element  
Register Bypass  
Packed  
LAB-wide  
Synchronous  
Load  
LAB-wide  
Synchronous  
Clear  
Register Select  
Programmable  
Register  
Carry-In  
Cascade-In  
data1  
data2  
data3  
data4  
To FastTrack Interconnect,  
MegaLAB Interconnect,  
or Local Interconnect  
Look-Up  
Table  
(LUT)  
Carry  
Chain  
Cascade  
Chain  
Synchronous  
Load & Clear  
Logic  
PRN  
D
Q
ENA  
CLRN  
To FastTrack Interconnect,  
MegaLAB Interconnect,  
or Local Interconnect  
labclr1  
labclr2  
Asynchronous  
Clear/Preset/  
Load Logic  
Chip-Wide  
Reset  
Clock & Clock  
Enable Select  
labclk1  
labclk2  
labclkena1  
labclkena2  
Carry-Out  
Cascade-Out  
Each LE’s programmable register can be configured for D, T, JK, or SR  
operation. The register’s clock and clear control signals can be driven by  
global signals, general-purpose I/O pins, or any internal logic. For  
combinatorial functions, the register is bypassed and the output of the  
LUT drives the outputs of the LE.  
Each LE has two outputs that drive the local, MegaLAB, or FastTrack  
interconnect routing structure. Each output can be driven independently  
by the LUT’s or register’s output. For example, the LUT can drive one  
output while the register drives the other output. This feature, called  
register packing, improves device utilization because the register and the  
LUT can be used for unrelated functions. The LE can also drive out  
registered and unregistered versions of the LUT output.  
12  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The APEX 20KC architecture provides two types of dedicated high-speed  
data paths that connect adjacent LEs without using local interconnect  
paths: carry chains and cascade chains. A carry chain supports high-speed  
arithmetic functions such as counters and adders, while a cascade chain  
implements wide-input functions such as equality comparators with  
minimum delay. Carry and cascade chains connect LEs 1 through 10 in an  
LAB and all LABs in the same MegaLAB structure.  
Carry Chain  
The carry chain provides a very fast carry-forward function between LEs.  
The carry-in signal from a lower-order bit drives forward into the higher-  
order bit via the carry chain, and feeds into both the LUT and the next  
portion of the carry chain. This feature allows the APEX 20KC architecture  
to implement high-speed counters, adders, and comparators of arbitrary  
width. Carry chain logic can be created automatically by the Quartus II  
Compiler during design processing, or manually by the designer during  
design entry. Parameterized functions such as DesignWare functions  
from Synopsys and library of parameterized modules (LPM) functions  
automatically take advantage of carry chains for the appropriate  
functions.  
The Quartus II Compiler creates carry chains longer than ten LEs by  
automatically linking LABs together. For enhanced fitting, a long carry  
chain skips alternate LABs in a MegaLAB structure. A carry chain longer  
than one LAB skips either from an even-numbered LAB to the next even-  
numbered LAB, or from an odd-numbered LAB to the next odd-  
numbered LAB. For example, the last LE of the first LAB in the upper-left  
MegaLAB structure carries to the first LE of the third LAB in the  
MegaLAB structure.  
Figure 6 shows how an n-bit full adder can be implemented in n + 1 LEs  
with the carry chain. One portion of the LUT generates the sum of two bits  
using the input signals and the carry-in signal; the sum is routed to the  
output of the LE. The register can be bypassed for simple adders or used  
for accumulator functions. Another portion of the LUT and the carry chain  
logic generates the carry-out signal, which is routed directly to the carry-  
in signal of the next-higher-order bit. The final carry-out signal is routed  
to an LE, where it is driven onto the local, MegaLAB, or FastTrack  
interconnect routing structures.  
Altera Corporation  
13  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 6. APEX 20KC Carry Chain  
Carry-In  
s1  
Register  
a1  
b1  
LUT  
Carry Chain  
LE1  
Register  
s2  
a2  
b2  
LUT  
Carry Chain  
LE2  
Register  
sn  
an  
bn  
LUT  
Carry Chain  
LEn  
Register  
Carry-Out  
LUT  
Carry Chain  
LEn + 1  
14  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Cascade Chain  
With the cascade chain, the APEX 20KC architecture can implement  
functions with a very wide fan-in. Adjacent LUTs can compute portions  
of a function in parallel; the cascade chain serially connects the  
intermediate values. The cascade chain can use a logical ANDor logical OR  
(via De Morgan’s inversion) to connect the outputs of adjacent LEs. Each  
additional LE provides four more inputs to the effective width of a  
function, with a short cascade delay. Cascade chain logic can be created  
automatically by the Quartus II Compiler during design processing, or  
manually by the designer during design entry.  
Cascade chains longer than ten LEs are implemented automatically by  
linking LABs together. For enhanced fitting, a long cascade chain skips  
alternate LABs in a MegaLAB structure. A cascade chain longer than one  
LAB skips either from an even-numbered LAB to the next even-numbered  
LAB, or from an odd-numbered LAB to the next odd-numbered LAB. For  
example, the last LE of the first LAB in the upper-left MegaLAB structure  
carries to the first LE of the third LAB in the MegaLAB structure. Figure 7  
shows how the cascade function can connect adjacent LEs to form  
functions with a wide fan-in.  
Figure 7. APEX 20KC Cascade Chain  
AND Cascade Chain  
OR Cascade Chain  
d[3..0]  
d[3..0]  
LUT  
LUT  
LUT  
LUT  
LE1  
LE2  
LE1  
LE2  
d[7..4]  
d[7..4]  
d[(4n – 1)..(4n – 4)]  
d[(4n – 1)..(4n – 4)]  
LUT  
LUT  
LEn  
LEn  
Altera Corporation  
15  
APEX 20KC Programmable Logic Device Data Sheet  
LE Operating Modes  
The APEX 20KC LE can operate in one of the following three modes:  
Normal mode  
Arithmetic mode  
Counter mode  
Each mode uses LE resources differently. In each mode, seven available  
inputs to the LE—the four data inputs from the LAB local interconnect,  
the feedback from the programmable register, and the carry-in and  
cascade-in from the previous LE—are directed to different destinations to  
implement the desired logic function. LAB-wide signals provide clock,  
asynchronous clear, asynchronous preset, asynchronous load,  
synchronous clear, synchronous load, and clock enable control for the  
register. These LAB-wide signals are available in all LE modes.  
The Quartus II software, in conjunction with parameterized functions  
such as LPM and DesignWare functions, automatically chooses the  
appropriate mode for common functions such as counters, adders, and  
multipliers. If required, the designer can also create special-purpose  
functions that specify which LE operating mode to use for optimal  
performance. Figure 8 shows the LE operating modes.  
16  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 8. APEX 20KC LE Operating Modes  
Normal Mode (1)  
LAB-Wide  
Clock Enable (2)  
Carry-In (3)  
Cascade-In  
data1  
data2  
4-Input  
LE Out  
PRN  
D
Q
LUT  
data3  
LE Out  
data4  
ENA  
CLRN  
Cascade-Out  
Arithmetic Mode  
LAB-Wide  
Clock Enable (2)  
Carry-In  
Cascade-In  
LE Out  
LE Out  
PRN  
data1  
data2  
D
Q
3-Input  
LUT  
ENA  
CLRN  
3-Input  
LUT  
Carry-Out Cascade-Out  
Counter Mode  
LAB-Wide  
Synchronous  
Clear (6)  
LAB-Wide  
LAB-Wide  
Synchronous  
Clock Enable (2)  
Load (6)  
Cascade-In  
Carry-In  
(4)  
data1 (5)  
LE Out  
PRN  
3-Input  
LUT  
data2 (5)  
D
Q
LE Out  
data3 (data)  
ENA  
CLRN  
3-Input  
LUT  
Carry-Out Cascade-Out  
Notes to Figure 8:  
(1) LEs in normal mode support register packing.  
(2) There are two LAB-wide clock enables per LAB.  
(3) When using the carry-in in normal mode, the packed register feature is unavailable.  
(4) A register feedback multiplexer is available on LE1 of each LAB.  
(5) The DATA1and DATA2input signals can supply counter enable, up or down control, or register feedback signals for  
LEs other than the second LE in an LAB.  
(6) The LAB-wide synchronous clear and LAB wide synchronous load affect all registers in an LAB.  
Altera Corporation  
17  
APEX 20KC Programmable Logic Device Data Sheet  
Normal Mode  
The normal mode is suitable for general logic applications, combinatorial  
functions, or wide decoding functions that can take advantage of a  
cascade chain. In normal mode, four data inputs from the LAB local  
interconnect and the carry-in are inputs to a four-input LUT. The  
Quartus II Compiler automatically selects the carry-in or the DATA3signal  
as one of the inputs to the LUT. The LUT output can be combined with the  
cascade-in signal to form a cascade chain through the cascade-out signal.  
LEs in normal mode support packed registers.  
Arithmetic Mode  
The arithmetic mode is ideal for implementing adders, accumulators, and  
comparators. An LE in arithmetic mode uses two 3-input LUTs. One LUT  
computes a three-input function; the other generates a carry output. As  
shown in Figure 8, the first LUT uses the carry-in signal and two data  
inputs from the LAB local interconnect to generate a combinatorial or  
registered output. For example, when implementing an adder, this output  
is the sum of three signals: DATA1, DATA2, and carry-in. The second LUT  
uses the same three signals to generate a carry-out signal, thereby creating  
a carry chain. The arithmetic mode also supports simultaneous use of the  
cascade chain. LEs in arithmetic mode can drive out registered and  
unregistered versions of the LUT output.  
The Quartus II software implements parameterized functions that use the  
arithmetic mode automatically where appropriate; the designer does not  
need to specify how the carry chain will be used.  
Counter Mode  
The counter mode offers clock enable, counter enable, synchronous  
up/down control, synchronous clear, and synchronous load options. The  
counter enable and synchronous up/down control signals are generated  
from the data inputs of the LAB local interconnect. The synchronous clear  
and synchronous load options are LAB-wide signals that affect all  
registers in the LAB. Consequently, if any of the LEs in an LAB use the  
counter mode, other LEs in that LAB must be used as part of the same  
counter or be used for a combinatorial function. The Quartus II software  
automatically places any registers that are not used by the counter into  
other LABs.  
18  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The counter mode uses two 3-input LUTs: one generates the counter data,  
and the other generates the fast carry bit. A 2-to-1 multiplexer provides  
synchronous loading, and another ANDgate provides synchronous  
clearing. If the cascade function is used by an LE in counter mode, the  
synchronous clear or load overrides any signal carried on the cascade  
chain. The synchronous clear overrides the synchronous load. LEs in  
arithmetic mode can drive out registered and unregistered versions of the  
LUT output.  
Clear & Preset Logic Control  
Logic for the register’s clear and preset signals is controlled by LAB-wide  
signals. The LE directly supports an asynchronous clear function. The  
Quartus II Compiler can use a NOT-gate push-back technique to emulate  
an asynchronous preset or to emulate simultaneous preset and clear or  
asynchronous load. However, this technique uses three additional LEs per  
register. All emulation is performed automatically when the design is  
compiled. Registers that emulate simultaneous preset and load will enter  
an unknown state upon power-up or when the chip-wide reset is asserted.  
In addition to the two clear and preset modes, APEX 20KC devices  
provide a chip-wide reset pin (DEV_CLRn) that resets all registers in the  
device. Use of this pin is controlled through an option in the Quartus II  
software that is set before compilation. The chip-wide reset overrides all  
other control signals. Registers using an asynchronous preset are preset  
when the chip-wide reset is asserted; this effect results from the inversion  
technique used to implement the asynchronous preset.  
FastTrack Interconnect  
In the APEX 20KC architecture, connections between LEs, ESBs, and I/O  
pins are provided by the FastTrack interconnect. The FastTrack  
interconnect is a series of continuous horizontal and vertical routing  
channels that traverse the device. This global routing structure provides  
predictable performance, even in complex designs. In contrast, the  
segmented routing in FPGAs requires switch matrices to connect a  
variable number of routing paths, increasing the delays between logic  
resources and reducing performance.  
The FastTrack interconnect consists of row and column interconnect  
channels that span the entire device. The row interconnect routes signals  
throughout a row of MegaLAB structures; the column interconnect routes  
signals throughout a column of MegaLAB structures. When using the row  
and column interconnect, an LE, IOE, or ESB can drive any other LE, IOE,  
or ESB in a device. See Figure 9.  
Altera Corporation  
19  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 9. APEX 20KC Interconnect Structure  
Row  
Interconnect  
I/O  
I/O  
I/O  
I/O  
MegaLAB  
I/O  
I/O  
MegaLAB  
MegaLAB  
MegaLAB  
MegaLAB  
MegaLAB  
MegaLAB  
I/O  
I/O  
MegaLAB  
Column  
Interconnect  
MegaLAB  
I/O  
MegaLAB  
MegaLAB  
MegaLAB  
I/O  
I/O  
I/O  
I/O  
I/O  
A row line can be driven directly by LEs, IOEs, or ESBs in that row.  
Further, a column line can drive a row line, allowing an LE, IOE, or ESB to  
drive elements in a different row via the column and row interconnect.  
The row interconnect drives the MegaLAB interconnect to drive LEs,  
IOEs, or ESBs in a particular MegaLAB structure.  
A column line can be directly driven by LEs, IOEs, or ESBs in that column.  
A column line on a device’s left or right edge can also be driven by row  
IOEs. The column line is used to route signals from one row to another. A  
column line can drive a row line; it can also drive the MegaLAB  
interconnect directly, allowing faster connections between rows.  
Figure 10 shows how the FastTrack interconnect uses the local  
interconnect to drive LEs within MegaLAB structures.  
20  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 10. FastTrack Connection to Local Interconnect  
I/O  
Row  
L
A
B
L
A
B
L
A
B
E
S
B
E
S
B
L
A
B
L
A
B
L
A
B
I/O  
MegaLAB  
Structure  
MegaLAB  
Structure  
Row & Column  
Column  
Interconnect Drives  
MegaLAB Interconnect  
Row  
MegaLAB  
Interconnect  
MegaLAB  
Interconnect Drives  
Local Interconnect  
Column  
L
A
B
L
A
B
E
S
B
Altera Corporation  
21  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 11 shows the intersection of a row and column interconnect, and  
how these forms of interconnects and LEs drive each other.  
Figure 11. Driving the FastTrack Interconnect  
Row Interconnect  
MegaLAB Interconnect  
Column  
Interconnect  
LE  
Local  
Interconnect  
APEX 20KC devices include an enhanced interconnect structure for faster  
routing of input signals with high fan-out. Column I/O pins can drive the  
FastRowTM interconnect, which routes signals directly into the local  
interconnect without having to drive through the MegaLAB interconnect.  
The FastRow lines traverse two MegaLAB structures. Also, these pins can  
drive the local interconnect directly for fast setup times. On EP20K400C  
and larger devices, the FastRow interconnect drives the two MegaLAB  
structures in the top left corner, the two MegaLAB structures in the two  
right corner, the two MegaLAB structures in the bottom left corner, and  
the two MegaLAB structures in the bottom right corner. On EP20K200C  
and smaller devices, FastRow interconnect drives the two MegaLAB  
structures on the top and the two MegaLAB structures on the bottom of  
the device. On all devices, the FastRow interconnect drives all local  
interconnect in the appropriate MegaLAB structures except the end local  
interconnect on the side of the MegaLAB opposite the ESB. Pins using the  
FastRow interconnect achieve a faster set-up time, as the signal does not  
need to use a MegaLAB interconnect line to reach the destination LE.  
Figure 12 shows the FastRow interconnect.  
22  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 12. APEX 20KC FastRow Interconnect  
Select Vertical I/O Pins  
Drive Local Interconnect  
and FastRow  
FastRow Interconnect  
Drives Local Interconnect  
in Two MegaLAB Structures  
IOE  
IOE  
IOE  
IOE  
FastRow  
Interconnect  
Interconnect  
Local  
Interconnect  
LEs  
MegaLAB  
MegaLAB  
LABs  
Table 8 summarizes how various elements of the APEX 20KC architecture  
drive each other.  
Altera Corporation  
23  
APEX 20KC Programmable Logic Device Data Sheet  
Table 8. APEX 20KC Routing Scheme  
Source  
Destination  
MegaLAB  
Row Column  
I/O Pin I/O Pin  
LE  
ESB  
Local  
Row  
Column  
FastTrack Interconnect  
Interconnect Interconnect  
FastRow  
Interconnect Interconnect FastTrack  
Row I/O pin  
v
v
v
v
v
Column I/O  
pin  
v
LE  
v
v
v
v
v
v
v
v
ESB  
Local  
interconnect  
v
v
v
v
MegaLAB  
interconnect  
v
Row  
FastTrack  
interconnect  
v
v
v
Column  
FastTrack  
interconnect  
v
FastRow  
interconnect  
v
Product-Term Logic  
The product-term portion of the MultiCore architecture is implemented  
with the ESB. The ESB can be configured to act as a block of macrocells on  
an ESB-by-ESB basis. Each ESB is fed by 32 inputs from the adjacent local  
interconnect; therefore, it can be driven by the MegaLAB interconnect or  
the adjacent LAB. Also, nine ESB macrocells feed back into the ESB  
through the local interconnect for higher performance. Dedicated clock  
pins, global signals, and additional inputs from the local interconnect  
drive the ESB control signals.  
In product-term mode, each ESB contains 16 macrocells. Each macrocell  
consists of two product terms and a programmable register. Figure 13  
shows the ESB in product-term mode.  
24  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 13. Product-Term Logic in ESB  
Dedicated Clocks  
Global Signals  
MegaLAB Interconnect  
4
4
65  
9
32  
Macrocell  
Inputs (1 to 16)  
To Row  
and Column  
Interconnect  
From  
Adjacent  
LAB  
2
2
2
16  
CLK[1..0]  
ENA[1..0]  
CLRN[1..0]  
Local  
Interconnect  
Macrocells  
APEX 20KC macrocells can be configured individually for either  
sequential or combinatorial logic operation. The macrocell consists of  
three functional blocks: the logic array, the product-term select matrix,  
and the programmable register.  
Combinatorial logic is implemented in the product terms. The product-  
term select matrix allocates these product terms for use as either primary  
logic inputs (to the ORand XORgates) to implement combinatorial  
functions, or as parallel expanders to be used to increase the logic  
available to another macrocell. One product term can be inverted; the  
Quartus II software uses this feature to perform De Morgan’s inversion for  
more efficient implementation of wide ORfunctions. The Quartus II  
Compiler can use a NOT-gate push-back technique to emulate an  
asynchronous preset. Figure 14 shows the APEX 20KC macrocell.  
Altera Corporation  
25  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 14. APEX 20KC Macrocell  
ESB-Wide ESB-Wide  
Clears Clock Enables  
ESB-Wide  
Clocks  
2
2
2
Parallel Logic  
Expanders  
(From Other  
Macrocells)  
Programmable  
Register  
ESB  
Output  
Product-  
Term  
D
Q
Select  
Matrix  
ENA  
CLRN  
Clock/  
Enable  
Select  
32 Signals  
from Local  
Interconnect  
Clear  
Select  
For registered functions, each macrocell register can be programmed  
individually to implement D, T, JK, or SR operation with programmable  
clock control. The register can be bypassed for combinatorial operation.  
During design entry, the designer specifies the desired register type; the  
Quartus II software then selects the most efficient register operation for  
each registered function to optimize resource utilization. The Quartus II  
software or other synthesis tools can also select the most efficient register  
operation automatically when synthesizing HDL designs.  
Each programmable register can be clocked by one of two ESB-wide  
clocks. The ESB-wide clocks can be generated from device dedicated clock  
pins, global signals, or local interconnect. Each clock also has an  
associated clock enable, generated from the local interconnect. The clock  
and clock enable signals are related for a particular ESB; any macrocell  
using a clock also uses the associated clock enable.  
If both the rising and falling edges of a clock are used in an ESB, both  
ESB-wide clock signals are used.  
26  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The programmable register also supports an asynchronous clear function.  
Within the ESB, two asynchronous clears are generated from global  
signals and the local interconnect. Each macrocell can either choose  
between the two asynchronous clear signals or choose to not be cleared.  
Either of the two clear signals can be inverted within the ESB. Figure 15  
shows the ESB control logic when implementing product-terms.  
Figure 15. ESB Product-Term Mode Control Logic  
4
Dedicated  
Clocks  
4
Global  
Signals  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
CLK1  
CLR2  
CLKENA1  
CLR1  
CLK2 CLKENA2  
Parallel Expanders  
Parallel expanders are unused product terms that can be allocated to a  
neighboring macrocell to implement fast, complex logic functions.  
Parallel expanders allow up to 32 product terms to feed the macrocell OR  
logic directly, with two product terms provided by the macrocell and  
30 parallel expanders provided by the neighboring macrocells in the ESB.  
The Quartus II Compiler can allocate up to 15 sets of up to two parallel  
expanders per set to the macrocells automatically. Each set of two parallel  
expanders incurs a small, incremental timing delay. Figure 16 shows the  
APEX 20KC parallel expanders.  
Altera Corporation  
27  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 16. APEX 20KC Parallel Expanders  
From  
Previous  
Macrocell  
Product-  
Term  
Select  
Matrix  
Macrocell  
Product-  
Term Logic  
Parallel  
Expander Switch  
Product-  
Term  
Select  
Matrix  
Macrocell  
Product-  
Term Logic  
Parallel  
Expander Switch  
32 Signals from  
Local Interconnect  
To Next  
Macrocell  
The ESB can implement various types of memory blocks, including  
dual-port RAM, ROM, FIFO, and CAM blocks. The ESB includes input  
and output registers; the input registers synchronize writes, and the  
output registers can pipeline designs to improve system performance. The  
ESB offers a dual-port mode, which supports simultaneous reads and  
writes at two different clock frequencies. Figure 17 shows the ESB block  
diagram.  
Embedded  
System Block  
Figure 17. ESB Block Diagram  
wraddress[]  
data[]  
rdaddress[]  
q[]  
wren  
rden  
inclock  
inclocken  
inaclr  
outclock  
outclocken  
outaclr  
28  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
ESBs can implement synchronous RAM, which is easier to use than  
asynchronous RAM. A circuit using asynchronous RAM must generate  
the RAM write enable (WE) signal, while ensuring that its data and address  
signals meet setup and hold time specifications relative to the WEsignal.  
In contrast, the ESB’s synchronous RAM generates its own WEsignal and  
is self-timed with respect to the global clock. Circuits using the ESB’s self-  
timed RAM must only meet the setup and hold time specifications of the  
global clock.  
ESB inputs are driven by the adjacent local interconnect, which in turn can  
be driven by the FastTrack or MegaLAB interconnect. Because the ESB can  
be driven by the local interconnect, an adjacent LE can drive it directly for  
fast memory access. ESB outputs drive the FastTrack and MegaLAB  
interconnects. In addition, ten ESB outputs, nine of which are unique  
output lines, drive the local interconnect for fast connection to adjacent  
LEs or for fast feedback product-term logic.  
When implementing memory, each ESB can be configured in any of the  
following sizes: 128 × 16, 256 × 8, 512 × 4, 1,024 × 2, or 2,048 × 1. By  
combining multiple ESBs, the Quartus II software implements larger  
memory blocks automatically. For example, two 128 × 16 RAM blocks can  
be combined to form a 128 × 32 RAM block, and two 512 × 4 RAM blocks  
can be combined to form a 512 × 8 RAM block. Memory performance does  
not degrade for memory blocks up to 2,048 words deep. Each ESB can  
implement a 2,048-word-deep memory; the ESBs are used in parallel,  
eliminating the need for any external control logic and its associated  
delays.  
To create a high-speed memory block that is more than 2,048 words deep,  
ESBs drive tri-state lines. Each tri-state line connects all ESBs in a column  
of MegaLAB structures, and drives the MegaLAB interconnect and row  
and column FastTrack interconnect throughout the column. Each ESB  
incorporates a programmable decoder to activate the tri-state driver  
appropriately. For instance, to implement 8,192-word-deep memory, four  
ESBs are used. Eleven address lines drive the ESB memory, and two more  
drive the tri-state decoder. Depending on which 2,048-word memory  
page is selected, the appropriate ESB driver is turned on, driving the  
output to the tri-state line. The Quartus II software automatically  
combines ESBs with tri-state lines to form deeper memory blocks. The  
internal tri-state control logic is designed to avoid internal contention and  
floating lines. See Figure 18.  
Altera Corporation  
29  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 18. Deep Memory Block Implemented with Multiple ESBs  
Address Decoder  
ESB  
ESB  
ESB  
to System Logic  
The ESB implements two forms of dual-port memory: read/write clock  
mode and input/output clock mode. The ESB can also be used for  
bidirectional, dual-port memory applications in which two ports read or  
write simultaneously. To implement this type of dual-port memory, two  
ESBs are used to support two simultaneous reads or writes.  
The ESB can also use Altera megafunctions to implement dual-port RAM  
applications where both ports can read or write, as shown in Figure 19.  
Figure 19. APEX 20KC ESB Implementing Dual-Port RAM  
Port A  
address_a[]  
data_a[]  
Port B  
address_b[]  
data_b[]  
we_a  
we_b  
clkena_a  
clkena_b  
Clock A  
Clock B  
30  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Read/Write Clock Mode  
The read/write clock mode contains two clocks. One clock controls all  
registers associated with writing: data input, WE, and write address. The  
other clock controls all registers associated with reading: read enable  
(RE), read address, and data output. The ESB also supports clock enable  
and asynchronous clear signals; these signals also control the read and  
write registers independently. Read/write clock mode is commonly used  
for applications where reads and writes occur at different system  
frequencies. Figure 20 shows the ESB in read/write clock mode.  
Figure 20. ESB in Read/Write Clock Mode  
Note (1)  
Dedicated Inputs &  
Global Signals  
Dedicated Clocks  
RAM/ROM  
4
4
128 × 16  
256 × 8  
512 × 4  
data[ ]  
Data In  
1,024 × 2  
2,048 × 1  
D
Q
To MegaLAB,  
FastTrack &  
Local  
ENA  
Data Out  
D
Q
Interconnect  
ENA  
ress[ ]  
wren  
Address  
D
Q
ENA  
Write Enable  
utclken  
nclken  
D
Q
Write  
Pulse  
ENA  
nclock  
tclock  
Generator  
Note to Figure 20:  
(1) All registers can be cleared asynchronously by ESB local interconnect signals, global signals, or the chip-wide reset.  
Altera Corporation  
31  
APEX 20KC Programmable Logic Device Data Sheet  
Input/Output Clock Mode  
The input/output clock mode contains two clocks. One clock controls all  
registers for inputs into the ESB: data input, WE, RE, read address, and  
write address. The other clock controls the ESB data output registers. The  
ESB also supports clock enable and asynchronous clear signals; these  
signals also control the reading and writing of registers independently.  
Input/output clock mode is commonly used for applications where the  
reads and writes occur at the same system frequency, but require different  
clock enable signals for the input and output registers. Figure 21 shows  
the ESB in input/output clock mode.  
Figure 21. ESB in Input/Output Clock Mode  
Note (1)  
Dedicated Inputs &  
Global Signals  
Dedicated Clocks  
RAM/ROM  
4
4
128 × 16  
256 × 8  
512 × 4  
data[ ]  
Data In  
1,024 × 2  
2,048 × 1  
D
Q
To MegaLAB,  
FastTrack &  
Local  
ENA  
Data Out  
D
Q
ENA  
Interconnect  
rdaddress[ ]  
Read Address  
Write Address  
D
Q
ENA  
wraddress[ ]  
rden  
D
Q
ENA  
Read Enable  
Write Enable  
D
Q
ENA  
wren  
outclken  
inclken  
D
Q
Write  
Pulse  
Generator  
ENA  
inclock  
outclock  
Note to Figure 21:  
(1) All registers can be cleared asynchronously by ESB local interconnect signals, global signals, or the chip-wide reset.  
32  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Single-Port Mode  
The APEX 20KC ESB also supports a single-port mode, which is used  
when simultaneous reads and writes are not required. See Figure 22.  
Figure 22. ESB in Single-Port Mode  
Note (1)  
Dedicated Inputs &  
Global Signals  
Dedicated Clocks  
RAM/ROM  
4
4
128 × 16  
256 × 8  
512 × 4  
data[ ]  
Data In  
1,024 × 2  
2,048 × 1  
D
Q
To MegaLAB,  
FastTrack &  
Local  
ENA  
Data Out  
D
Q
Interconnect  
ENA  
address[ ]  
wren  
Address  
D
Q
ENA  
Write Enable  
outclken  
inclken  
D
Q
Write  
Pulse  
ENA  
inclock  
Generator  
outclock  
Note toFigure 22:  
(1) All registers can be asynchronously cleared by ESB local interconnect signals, global signals, or the chip-wide reset.  
Content-Addressable Memory  
In APEX 20KC devices, the ESB can implement CAM. CAM can be  
thought of as the inverse of RAM. When read, RAM outputs the data for  
a given address. Conversely, CAM outputs an address for a given data  
word. For example, if the data FA12is stored in address 14, the CAM  
outputs 14when FA12is driven into it.  
Altera Corporation  
33  
APEX 20KC Programmable Logic Device Data Sheet  
CAM is used for high-speed search operations. When searching for data  
within a RAM block, the search is performed serially. Thus, finding a  
particular data word can take many cycles. CAM searches all addresses in  
parallel and outputs the address storing a particular word. When a match  
is found, a match flag is set high. Figure 23 shows the CAM block  
diagram.  
34  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 23. APEX 20KC CAM Block Diagram  
wraddress[]  
data[]  
data_address[]  
match  
wren  
outclock  
inclock  
inclocken  
inaclr  
outclocken  
outaclr  
CAM can be used in any application requiring high-speed searches, such  
as networking, communications, data compression, and cache  
management.  
The APEX 20KC on-chip CAM provides faster system performance than  
traditional discrete CAM. Integrating CAM and logic into the APEX 20KC  
device eliminates off-chip and on-chip delays, improving system  
performance.  
When in CAM mode, the ESB implements 32-word, 32-bit CAM. Wider or  
deeper CAM can be implemented by combining multiple CAMs with  
some ancillary logic implemented in LEs. The Quartus II software  
combines ESBs and LEs automatically to create larger CAMs.  
CAM supports writing “don’t care” bits into words of the memory. The  
“don’t care” bit can be used as a mask for CAM comparisons; any bit set  
to “don’t care” has no effect on matches.  
The output of the CAM can be encoded or unencoded. When encoded, the  
ESB outputs an encoded address of the data’s location. For instance, if the  
data is located in address 12, the ESB output is 12. When unencoded, the  
ESB uses its 16 outputs to show the location of the data over two clock  
cycles. In this case, if the data is located in address 12, the 12th output line  
goes high. When using unencoded outputs, two clock cycles are required  
to read the output because a 16-bit output bus is used to show the status  
of 32 words.  
The encoded output is better suited for designs that ensure duplicate data  
is not written into the CAM. If duplicate data is written into two locations,  
the CAM’s output will be incorrect. If the CAM may contain duplicate  
data, the unencoded output is a better solution; CAM with unencoded  
outputs can distinguish multiple data locations.  
CAM can be pre-loaded with data during configuration, or it can be  
written during system operation. In most cases, two clock cycles are  
required to write each word into CAM. When “don’t care” bits are used,  
a third clock cycle is required.  
Altera Corporation  
35  
APEX 20KC Programmable Logic Device Data Sheet  
For more information on APEX 20KC devices and CAM, see Application  
Note 119 (Implementing High-Speed Search Applications with APEX CAM).  
f
Driving Signals to the ESB  
ESBs provide flexible options for driving control signals. Different clocks  
can be used for the ESB inputs and outputs. Registers can be inserted  
independently on the data input, data output, read address, write  
address, WE, and REsignals. The global signals and the local interconnect  
can drive the WEand REsignals. The global signals, dedicated clock pins,  
and local interconnect can drive the ESB clock signals. Because the LEs  
drive the local interconnect, the LEs can control the WEand REsignals and  
the ESB clock, clock enable, and asynchronous clear signals. Figure 24  
shows the ESB control signal generation logic.  
Figure 24. ESB Control Signal Generation  
4
Dedicated  
Clocks  
4
Global  
Signals  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
Local  
Interconnect  
INCLKENA  
OUTCLKENA  
WREN  
OUTCLR  
Local  
Interconnect  
RDEN  
INCLOCK  
OUTCLOCK  
INCLR  
An ESB is fed by the local interconnect, which is driven by adjacent LEs  
(for high-speed connection to the ESB) or the MegaLAB interconnect. The  
ESB can drive the local, MegaLAB, or FastTrack interconnect routing  
structure to drive LEs and IOEs in the same MegaLAB structure or  
anywhere in the device.  
36  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Implementing Logic in ROM  
In addition to implementing logic with product terms, the ESB can  
implement logic functions when it is programmed with a read-only  
pattern during configuration, creating a large LUT. With LUTs,  
combinatorial functions are implemented by looking up the results, rather  
than by computing them. This implementation of combinatorial functions  
can be faster than using algorithms implemented in general logic, a  
performance advantage that is further enhanced by the fast access times  
of ESBs. The large capacity of ESBs enables designers to implement  
complex functions in one logic level without the routing delays associated  
with linked LEs or distributed RAM blocks. Parameterized functions such  
as LPM functions can take advantage of the ESB automatically. Further,  
the Quartus II software can implement portions of a design with ESBs  
where appropriate.  
Programmable Speed/Power Control  
APEX 20KC ESBs offer a high-speed mode that supports very fast  
operation on an ESB-by-ESB basis. When high speed is not required, this  
feature can be turned off to reduce the ESB’s power dissipation by up to  
50%. ESBs that run at low power incur a nominal timing delay adder. This  
Turbo BitTM option is available for ESBs that implement product-term  
logic or memory functions. An ESB that is not used will be powered down  
so that it does not consume DC current.  
Designers can program each ESB in the APEX 20KC device for either  
high-speed or low-power operation. As a result, speed-critical paths in the  
design can run at high speed, while the remaining paths operate at  
reduced power.  
The APEX 20KC IOE contains a bidirectional I/O buffer and a register  
that can be used either as an input register for external data requiring fast  
setup times or as an output register for data requiring fast clock-to-output  
performance. IOEs can be used as input, output, or bidirectional pins.  
I/O Structure  
Altera Corporation  
37  
APEX 20KC Programmable Logic Device Data Sheet  
APEX 20KC devices include an enhanced IOE, which drives the FastRow  
interconnect. The FastRow interconnect connects a column I/O pin  
directly to the LAB local interconnect within two MegaLAB structures.  
This feature provides fast setup times for pins that drive high fan-outs  
with complex logic, such as PCI designs. For fast bidirectional I/O timing,  
LE registers using local routing can improve setup times and OE timing.  
The APEX 20KC IOE also includes direct support for open-drain  
operation, giving faster clock-to-output for open-drain signals. Some  
programmable delays in the APEX 20KC IOE offer multiple levels of  
delay to fine-tune setup and hold time requirements. The Quartus II  
Compiler sets these delays by default to minimize setup time while  
providing a zero hold time.  
The Quartus II Compiler uses the programmable inversion option to  
invert signals from the row and column interconnect automatically where  
appropriate. Because the APEX 20KC IOE offers one output enable per  
pin, the Quartus II Compiler can emulate open-drain operation efficiently.  
The APEX 20KC IOE includes programmable delays that can be activated  
to ensure zero hold times, minimum clock-to-output times, input IOE  
register-to-core register transfers, or core-to-output IOE register transfers.  
A path in which a pin directly drives a register may require the delay to  
ensure zero hold time, whereas a path in which a pin drives a register  
through combinatorial logic may not require the delay.  
Table 9 describes the APEX 20KC programmable delays and their logic  
options in the Quartus II software.  
Table 9. APEX 20KC Programmable Delay Chains  
Programmable Delay  
Quartus II Logic Option  
Input pin to core delay  
Decrease input delay to internal cells  
Decrease input delay to input registers  
Decrease input delay to output register  
Increase delay to output pin  
Input pin to input register delay  
Core to output register delay  
Output register tCO delay  
Clock enable delay  
Increase clock enable delay  
The Quartus II Compiler can program these delays automatically to  
minimize setup time while providing a zero hold time.  
38  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The register in the APEX 20KC IOE can be programmed to power-up high  
or low after configuration is complete. If it is programmed to power-up  
low, an asynchronous clear can control the register. If it is programmed to  
power-up high, an asynchronous preset can control the register. This  
feature is useful for cases where the APEX 20KC device controls an active-  
low input or another device; it prevents inadvertent activation of the input  
upon power-up.  
Figure 25 shows how fast bidirectional I/O pins are implemented in  
APEX 20KC devices. This feature is useful for cases where the APEX 20KC  
device controls an active-low input or another device; it prevents  
inadvertent activation of the input upon power-up.  
Altera Corporation  
39  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 25. APEX 20KC Bidirectional I/O Registers  
Notes (1), (2)  
Row, Column, FastRow,  
4 Dedicated  
or Local Interconnect Clock Inputs  
Peripheral Control  
Bus  
4 Dedicated  
Inputs  
OE Register  
D
Q
ENA  
CLRN  
VCC  
Chip-Wide Reset  
VCC  
Chip-Wide  
Output Enable  
OE[7..0]  
VCCIO  
Input Pin to  
Optional  
Core Delay (1)  
PCI Clamp  
Input Pin to  
Core Delay (1)  
12  
4
VCC  
Output Register  
Delay  
Output Register  
Core to Output  
Register Delay  
t
CO  
Q
D
Open-Drain  
Output  
Input Pin to Input  
Register Delay  
ENA  
CLRN/  
PRN  
CLK[1..0]  
Slew-Rate  
Control  
CLK[3..0]  
ENA[5..0]  
VCC  
Clock Enable  
Delay (1)  
VCC  
CLRn[1..0]  
Input Pin to  
Core Delay (1)  
Chip-Wide  
Reset  
Input Register  
D
Q
VCC  
ENA  
CLRN  
VCC  
Chip-Wide  
Reset  
40  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Notes to Figure 25:  
(1) This programmable delay has four settings: off and three levels of delay.  
(2) The output enable and input registers are LE registers in the LAB adjacent to the bidirectional pin.  
Each IOE drives a row, column, MegaLAB, or local interconnect when  
used as an input or bidirectional pin. A row IOE can drive a local,  
MegaLAB, row, and column interconnect; a column IOE can drive the  
column interconnect. Figure 26 shows how a row IOE connects to the  
interconnect.  
Figure 26. Row IOE Connection to the Interconnect  
Row Interconnect  
MegaLAB Interconnect  
Any LE can drive a  
pin through the row,  
column, and MegaLAB  
interconnect.  
Each IOE can drive local,  
IOE  
IOE  
MegaLAB, row, and column  
interconnect. Each IOE data  
and OE signal is driven by  
the local interconnect.  
LAB  
An LE can drive a pin through the  
local interconnect for faster  
clock-to-output times.  
Altera Corporation  
41  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 27 shows how a column IOE connects to the interconnect.  
Figure 27. Column IOE Connection to the Interconnect  
Each IOE can drive a column interconnect. IOEs can also  
drive FastRow and column interconnects. Each IOE data  
and OE signal is driven by local interconnect.  
IOE  
IOE  
An LE or ESB can drive a  
pin through a local  
interconnect for faster  
clock-to-output times.  
LAB  
Any LE or ESB can drive  
a column pin through a  
row, column, and MegaLAB  
interconnect.  
Column Interconnect  
MegaLAB Interconnect  
Row Interconnect  
Dedicated Fast I/O Pins  
APEX 20KC devices incorporate an enhancement to support bidirectional  
pins with high internal fan-out such as PCI control signals. These pins are  
called dedicated fast I/O pins (FAST1, FAST2, FAST3, and FAST4) and  
replace dedicated inputs. These pins can be used for fast clock, clear, or  
high fan-out logic signal distribution. They also can drive out. The  
dedicated fast I/O pin data output and tri-state control are driven by local  
interconnect from the adjacent MegaLAB for high speed.  
42  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Advanced I/O Standard Support  
APEX 20KC IOEs support the following I/O standards: LVTTL,  
LVCMOS, 1.8-V I/O, 2.5-V I/O, 3.3-V PCI, PCI-X, 3.3-V AGP, LVDS,  
LVPECL, GTL+, CTT, HSTL Class I, SSTL-3 Class I and II, and SSTL-2  
Class I and II.  
For more information on I/O standards supported by APEX 20KC  
devices, see Application Note 117 (Using Selectable I/O Standards in Altera  
Devices).  
f
The APEX 20KC device contains eight I/O banks. In QFP packages, the  
banks are linked to form four I/O banks. The I/O banks directly support  
all standards except LVDS and LVPECL. All I/O banks can support LVDS  
and LVPECL at up to 156 Mbps per channel with the addition of external  
resistors. In addition, one block within a bank contains circuitry to  
support high-speed True-LVDS and LVPECL inputs, and another block  
within a bank supports high-speed True-LVDS and LVPECL outputs. The  
LVDS blocks support all of the I/O standards. Each I/O bank has its own  
VCCIOpins. A single device can support 1.8-V, 2.5-V, and 3.3-V interfaces;  
each bank can support a different standard independently. Each bank can  
also use a separate VREF level so that each bank can support any of the  
terminated standards (such as SSTL-3) independently. Within a bank, any  
one of the terminated standards can be supported. EP20K400C and larger  
APEX 20KC devices support the LVDS interface for data pins (EP20K200C  
devices support LVDS clock pins, but not data pins). EP20K400C and  
EP20K600C devices support LVDS for data pins at up to 840 Mbps per  
channel. EP20K1000C devices support LVDS on 16 channels at up to 750  
Mbps.  
Each bank can support multiple standards with the same VCCIOfor  
output pins. Each bank can support one voltage-referenced I/O standard,  
but it can support multiple I/O standards with the same VCCIOvoltage  
level. For example, when VCCIO is 3.3 V, a bank can support LVTTL,  
LVCMOS, 3.3-V PCI, and SSTL-3 for inputs and outputs.  
When the LVDS banks are not used for the LVDS I/O standard, they  
support all of the other I/O standards. Figure 28 shows the arrangement  
of the APEX 20KC I/O banks.  
Altera Corporation  
43  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 28. APEX 20KC I/O Banks  
I/O Bank 1  
I/O Bank 2  
I/O Bank 3  
(1)  
Regular I/O Banks Support  
LVPECL  
LVTTL  
LVCMOS  
2.5 V  
1.8 V  
3.3-V PCI  
GTL+  
I/O Bank 8  
LVDS Input  
Block (2)  
HSTL  
LVDS Output  
Block (2)  
SSTL-2 Class I and II  
SSTL-3 Class I and II  
CTT  
AGP  
I/O Bank 4  
(1)  
Individual  
Power Bus  
I/O Bank 7  
I/O Bank 6  
I/O Bank 5  
Notes to Figure 28:  
(1) For more information on placing I/O pins in LVDS blocks, refer to the “Guidelines for Using LVDS Blocks” section  
in Application Note 120 (Using LVDS in APEX 20KE Devices).  
(2) If the LVDS input and output blocks are not used for LVDS, they can support all of the I/O standards and can be  
used as input, output, or bidirectional pins with VCCIO set to 3.3 V, 2.5 V, or 1.8 V.  
Power Sequencing & Hot Socketing  
Because APEX 20KC devices can be used in a mixed-voltage environment,  
they have been designed specifically to tolerate any possible power-up  
sequence. Therefore, the VCCIO and VCCINT power supplies may be  
powered in any order.  
44  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Signals can be driven into APEX 20KC devices before and during power-  
up without damaging the device. In addition, APEX 20KC devices do not  
drive out during power-up. Once operating conditions are reached and  
the device is configured, APEX 20KC devices operate as specified by the  
user.  
The APEX architecture supports the MultiVolt I/O interface feature,  
which allows APEX devices in all packages to interface with systems of  
different supply voltages. The devices have one set of VCC pins for  
internal operation and input buffers (VCCINT), and another set for I/O  
output drivers (VCCIO).  
MultiVolt I/O  
Interface  
APEX 20KC devices support the MultiVolt I/O interface feature. The  
APEX 20KC VCCINT pins must always be connected to a 1.8-V power  
supply. With a 1.8-V VCCINT level, input pins are 1.8-V, 2.5-V, and 3.3-V  
tolerant. The VCCIO pins can be connected to either a 1.8-V, 2.5-V, or 3.3-V  
power supply, depending on the I/O standard requirements. When the  
VCCIO pins are connected to a 1.8-V power supply, the output levels are  
compatible with 1.8-V systems. When VCCIO pins are connected to a 2.5-V  
power supply, the output levels are compatible with 2.5-V systems. When  
VCCIO pins are connected to a 3.3-V power supply, the output high is  
3.3 V and compatible with 3.3-V or 5.0-V systems. An APEX 20KC device  
is 5.0-V tolerant with the addition of a resistor and the PCI clamp diode  
enabled.  
For more information on 5.0-V tolerance, refer to the “5.0-V Tolerance in  
APEX 20KE Devices White Paper,” as the information found therein also  
applies to APEX 20KC devices.  
f
Table 10 summarizes APEX 20KC MultiVolt I/O support.  
Table 10. APEX 20KC MultiVolt I/O Support  
VCCIO (V)  
Input Signals (V)  
Output Signals (V)  
1.8  
2.5  
3.3  
5.0  
1.8  
2.5  
3.3  
5.0  
1.8  
2.5  
3.3  
v
v (1)  
v
v (1)  
v (1)  
v
v
v
v
v (2)  
v (3)  
v
v
Notes to Table 10:  
(1) The PCI clamping diode must be disabled to drive an input with voltages higher than VCCIO, except for the 5.0-V  
input case.  
(2) An APEX 20KC device can be made 5.0-V tolerant with the addition of an external resistor and the PCI clamp diode  
enabled.  
(3) When VCCIO = 3.3 V, an APEX 20KC device can drive a 2.5-V device with 3.3-V tolerant inputs.  
Altera Corporation  
45  
APEX 20KC Programmable Logic Device Data Sheet  
Open-drain output pins on APEX 20KC devices (with a series resistor and  
a pull-up resistor to the 5.0-V supply) can drive 5.0-V CMOS input pins  
that require a VIH of 3.5 V. When the pin is inactive, the trace will be pulled  
up to 5.0 V by the resistor. The open-drain pin will only drive low or tri-  
state; it will never drive high. The rise time is dependent on the value of  
the pull-up resistor and load impedance. The IOL current specification  
should be considered when selecting a pull-up resistor.  
APEX 20KC devices support the ClockLock and ClockBoost clock  
management features, which are implemented with PLLs. The ClockLock  
circuitry uses a synchronizing PLL that reduces the clock delay and skew  
within a device. This reduction minimizes clock-to-output and setup  
times while maintaining zero hold times. The ClockBoost circuitry, which  
provides a clock multiplier, allows the designer to enhance device area  
efficiency by sharing resources within the device. The ClockBoost  
circuitry allows the designer to distribute a low-speed clock and multiply  
that clock on-device. APEX 20KC devices include a high-speed clock tree;  
unlike ASICs, the user does not have to design and optimize the clock tree.  
The ClockLock and ClockBoost features work in conjunction with the  
APEX 20KC device’s high-speed clock to provide significant  
ClockLock &  
ClockBoost  
Features  
improvements in system performance and bandwidth. APEX 20KC  
devices in -7 and -8 speed grades have PLLs and support the ClockLock  
and ClockBoost features.  
The ClockLock and ClockBoost features in APEX 20KC devices are  
enabled through the Quartus II software. External devices are not  
required to use these features.  
APEX 20KC ClockLock Feature  
APEX 20KC devices include up to four PLLs, which can be used  
independently. Two PLLs are designed for either general-purpose use or  
LVDS use (on devices that support LVDS I/O pins). The remaining two  
PLLs are designed for general-purpose use. The EP20K200C devices have  
two PLLs; the EP20K400C and larger devices have four PLLs.  
The following sections describe some of the features offered by the  
APEX 20KC PLLs.  
External PLL Feedback  
The ClockLock circuit’s output can be driven off-chip to clock other  
devices in the system; further, the feedback loop of the PLL can be routed  
off-chip. This feature allows the designer to exercise fine control over the  
I/O interface between the APEX 20KC device and another high-speed  
device, such as SDRAM.  
46  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Clock Multiplication  
The APEX 20KC ClockBoost circuit can multiply or divide clocks by a  
programmable number. The clock can be multiplied by m/(n × k), where  
m and k range from 2 to 160 and n ranges from 1 to 16. Clock multiplication  
and division can be used for time-domain multiplexing and other  
functions, which can reduce design LE requirements.  
Clock Phase & Delay Adjustment  
The APEX 20KC ClockShift feature allows the clock phase and delay to be  
adjusted. The clock phase can be adjusted by 90° steps. The clock delay  
can be adjusted to increase or decrease the clock delay by an arbitrary  
amount, up to one clock period.  
LVDS Support  
All APEX 20KC devices support differential LVDS buffers on the input  
and output clock signals that interface with external devices. This is  
controlled in the Quartus II software by assigning the clock pins with an  
LVDS I/O standard assignment.  
Two high-speed PLLs are designed to support the LVDS interface. When  
using LVDS, the I/O clock runs at a slower rate than the data transfer rate.  
Thus, PLLs are used to multiply the I/O clock internally to capture the  
LVDS data. For example, an I/O clock may run at 105 MHz to support  
840 Mbps LVDS data transfer. In this example, the PLL multiplies the  
incoming clock by eight to support the high-speed data transfer. You can  
use PLLs in EP20K400C and larger devices for high-speed LVDS  
interfacing.  
Lock Signals  
The APEX 20KC ClockLock circuitry supports individual LOCK signals.  
The LOCK signal drives high when the ClockLock circuit has locked onto  
the input clock. The LOCK signals are optional for each ClockLock circuit;  
when not used, they are I/O pins.  
Altera Corporation  
47  
APEX 20KC Programmable Logic Device Data Sheet  
ClockLock & ClockBoost Timing Parameters  
For the ClockLock and ClockBoost circuitry to function properly, the  
incoming clock must meet certain requirements. If these specifications are  
not met, the circuitry may not lock onto the incoming clock, which  
generates an erroneous clock within the device. The clock generated by  
the ClockLock and ClockBoost circuitry must also meet certain  
specifications. If the incoming clock meets these requirements during  
configuration, the APEX 20KC ClockLock and ClockBoost circuitry will  
lock onto the clock during configuration. The circuit will be ready for use  
immediately after configuration. In APEX 20KC devices, the clock input  
standard is programmable, so the PLL cannot respond to the clock until  
the device is configured. The PLL locks onto the input clock as soon as  
configuration is complete. Figure 29 shows the incoming and generated  
clock specifications.  
1
For more information on ClockLock and ClockBoost circuitry,  
see Application Note 115: Using the ClockLock and ClockBoost PLL  
Features in APEX Devices.  
Figure 29. Specifications for the Incoming & Generated Clocks  
The tI parameter refers to the nominal input clock period; the tO parameter refers to the  
nominal output clock period.  
+
f
,
CLK1 fCLK2  
,
tINDUTY  
tI tCLKDEV  
fCLK4  
Input  
Clock  
+
tI tINCLKSTB  
tR (1) tF (1)  
tO  
tOUTDUTY  
ClockLock  
Generated  
Clock  
+
tO  
tO tJITTER  
tO tJITTER  
Note to Figure 29:  
(1) Rise and fall times are measured from 10% to 90%.  
48  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Tables 11 and 12 summarize the ClockLock and ClockBoost parameters  
for APEX 20KC devices.  
Table 11. APEX 20KC ClockLock & ClockBoost Parameters  
Symbol Parameter Condition  
Note (1)  
Min  
Typ  
Max  
Unit  
tR  
tF  
Input rise time  
5
5
ns  
ns  
%
Input fall time  
tINDUTY  
Input duty cycle  
40  
45  
60  
tINJITTER  
Input jitter peak-to-peak  
2% of input  
period  
%
tOUTJITTER RMS jitter on ClockLock or  
0.35% of  
output  
period  
%
ClockBoost-generated clock  
tOUTDUTY  
Duty cycle for ClockLock or  
ClockBoost-generated clock  
55  
40  
%
tLOCK (2), (3) Time required for ClockLock or  
µs  
ClockBoost to acquire lock  
Table 12. APEX 20KC Clock Input & Output Parameters (Part 1 of 2)  
Note (1)  
Symbol  
Parameter  
I/O Standard  
-7 Speed Grade  
-8 Speed Grade Units  
Min  
Max  
Min  
Max  
fVCO (4)  
fCLOCK0  
fCLOCK1  
Voltage controlled oscillator  
operating range  
200  
500  
200  
500  
MHz  
MHz  
MHz  
Clock0 PLL output frequency  
for internal use  
1.5  
20  
335  
335  
1.5  
20  
200  
200  
Clock1 PLL output frequency  
for internal use  
fCLOCK0_EXT Output clock frequency for  
3.3-V LVTTL  
2.5-V LVTTL  
1.8-V LVTTL  
GTL+  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
external clock0 output  
SSTL-2 Class I  
SSTL-2 Class II  
SSTL-3 Class I  
SSTL-3 Class II  
LVDS  
Altera Corporation  
49  
APEX 20KC Programmable Logic Device Data Sheet  
Table 12. APEX 20KC Clock Input & Output Parameters (Part 2 of 2)  
Note (1)  
Symbol  
Parameter  
I/O Standard  
-7 Speed Grade  
-8 Speed Grade Units  
Min  
Max  
Min  
Max  
fCLOCK1_EXT Output clock frequency for  
3.3-V LVTTL  
2.5-V LVTTL  
1.8-V LVTTL  
GTL+  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
(5)  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
external clock1 output  
SSTL-2 Class I  
SSTL-2 Class II  
SSTL-3 Class I  
SSTL-3 Class II  
LVDS  
fIN  
Input clock frequency  
3.3-V LVTTL  
2.5-V LVTTL  
1.8-V LVTTL  
GTL+  
SSTL-2 Class I  
SSTL-2 Class II  
SSTL-3 Class I  
SSTL-3 Class II  
LVDS  
Notes to Tables 11 and 12:  
(1) All input clock specifications must be met. The PLL may not lock onto an incoming clock if the clock specifications  
are not met, creating an erroneous clock within the device.  
(2) The maximum lock time is 40 µs or 2,000 input clock cycles, whichever occurs first.  
(3) Before configuration, the PLL circuits are disable and powered down. During configuration, the PLLs remain  
disabled. The PLLs begin to lock once the device is in the user mode. If the clock enable feature is used, lock begins  
once the CLKLK_ENApin goes high in user mode.  
(4) The PLL VCO operating range is 200 MHz fVCO 840 MHz for LVDS mode.  
(5) Contact Altera Applications for information on these parameters.  
APEX 20KC devices include device enhancements to support the  
SignalTap embedded logic analyzer. By including this circuitry, the  
APEX 20KC device provides the ability to monitor design operation over  
a period of time through the IEEE Std. 1149.1 (JTAG) circuitry; a designer  
SignalTap  
Embedded  
Logic Analyzer  
can analyze internal logic at speed without bringing internal signals to the  
I/O pins. This feature is particularly important for advanced packages  
such as FineLine BGA packages because adding a connection to a pin  
during the debugging process can be difficult after a board is designed  
and manufactured.  
50  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
All APEX 20KC devices provide JTAG BST circuitry that complies with  
the IEEE Std. 1149.1-1990 specification. JTAG boundary-scan testing can  
be performed before or after configuration, but not during configuration.  
APEX 20KC devices can also use the JTAG port for configuration with the  
Quartus II software or with hardware using either Jam Files (.jam) or Jam  
Byte-Code Files (.jbc). Finally, APEX 20KC devices use the JTAG port to  
monitor the logic operation of the device with the SignalTap embedded  
logic analyzer. APEX 20KC devices support the JTAG instructions shown  
in Table 13.  
IEEE Std.  
1149.1 (JTAG)  
Boundary-Scan  
Support  
Table 13. APEX 20KC JTAG Instructions  
JTAG Instruction  
Description  
SAMPLE/PRELOAD Allows a snapshot of signals at the device pins to be captured and examined during  
normal device operation, and permits an initial data pattern to be output at the device pins.  
Also used by the SignalTap embedded logic analyzer.  
EXTEST  
Allows the external circuitry and board-level interconnections to be tested by forcing a test  
pattern at the output pins and capturing test results at the input pins.  
BYPASS  
Places the 1-bit bypass register between the TDIand TDOpins, which allows the BST data  
to pass synchronously through selected devices to adjacent devices during normal device  
operation.  
USERCODE  
IDCODE  
Selects the 32-bit USERCODE register and places it between the TDIand TDOpins,  
allowing the USERCODE to be serially shifted out of TDO.  
Selects the IDCODE register and places it between TDIand TDO, allowing the IDCODE  
to be serially shifted out of TDO.  
ICR Instructions  
Used when configuring an APEX 20KC device via the JTAG port with a MasterBlasterTM  
or ByteBlasterMVTM download cable, or when using a Jam File or Jam Byte-Code File via  
an embedded processor.  
SignalTap  
Monitors internal device operation with the SignalTap embedded logic analyzer.  
Instructions  
Altera Corporation  
51  
APEX 20KC Programmable Logic Device Data Sheet  
The APEX 20KC device instruction register length is 10 bits. The  
APEX 20KC device USERCODE register length is 32 bits. Tables 14 and 15  
show the boundary-scan register length and device IDCODE information  
for APEX 20KC devices.  
Table 14. APEX 20KC Boundary-Scan Register Length  
Device  
Boundary-Scan Register Length  
EP20K200C  
EP20K400C  
EP20K600C  
EP20K1000C  
1,164  
1,506  
1,806  
2,190  
Table 15. 32-Bit APEX 20KC Device IDCODE  
Device  
IDCODE (32 Bits) (1)  
Part Number (16 Bits)  
Version  
(4 Bits)  
Manufacturer  
Identity (11 Bits)  
1 (1 Bit)  
(2)  
EP20K200C  
EP20K400C  
EP20K600C  
EP20K1000C  
0000  
0000  
0000  
0000  
1000 0010 0000 0000  
1000 0100 0000 0000  
1000 0110 0000 0000  
1001 0000 0000 0000  
000 0110 1110  
000 0110 1110  
000 0110 1110  
000 0110 1110  
1
1
1
1
Notes to Table 15:  
(1) The most significant bit (MSB) is on the left.  
(2) The IDCODE’s least significant bit (LSB) is always 1.  
Figure 30 shows the timing requirements for the JTAG signals.  
52  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 30. APEX 20KC JTAG Waveforms  
TMS  
TDI  
tJCP  
tJCH  
t JCL  
tJPH  
tJPSU  
TCK  
TDO  
tJPXZ  
tJPZX  
tJPCO  
tJSSU  
tJSH  
Signal  
to Be  
Captured  
tJSCO  
tJSZX  
tJSXZ  
Signal  
to Be  
Driven  
Table 16 shows the JTAG timing parameters and values for APEX 20KC  
devices.  
Table 16. APEX 20KC JTAG Timing Parameters & Values  
Symbol  
Parameter  
Min Max Unit  
t
t
t
t
t
t
t
t
t
t
t
t
t
TCKclock period  
100  
50  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
JCP  
TCKclock high time  
TCKclock low time  
JTAG port setup time  
JTAG port hold time  
JCH  
50  
JCL  
20  
45  
JPSU  
JPH  
JTAG port clock to output  
25  
25  
25  
JPCO  
JPZX  
JPXZ  
JSSU  
JSH  
JTAG port high impedance to valid output  
JTAG port valid output to high impedance  
Capture register setup time  
20  
45  
Capture register hold time  
Update register clock to output  
35  
35  
35  
JSCO  
JSZX  
JSXZ  
Update register high impedance to valid output  
Update register valid output to high impedance  
For more information, see the following documents:  
f
Application Note 39 (IEEE Std. 1149.1 (JTAG) Boundary-Scan Testing in  
Altera Devices)  
Altera Corporation  
53  
APEX 20KC Programmable Logic Device Data Sheet  
Jam Programming & Test Language Specification  
Each APEX 20KC device is functionally tested. Complete testing of each  
configurable SRAM bit and all logic functionality ensures 100% yield.  
AC test measurements for APEX 20KC devices are made under conditions  
equivalent to those defined in the “Timing Model” section on page 65.  
Multiple test patterns can be used to configure devices during all stages of  
the production flow. AC test criteria include:  
Generic Testing  
Power supply transients can affect AC measurements.  
Simultaneous transitions of multiple outputs should be avoided for  
accurate measurement.  
Threshold tests must not be performed under AC conditions.  
Large-amplitude, fast-ground-current transients normally occur as  
the device outputs discharge the load capacitances. When these  
transients flow through the parasitic inductance between the device  
ground pin and the test system ground, significant reductions in  
observable noise immunity can result.  
Tables 17 through 20 provide information on absolute maximum ratings,  
recommended operating conditions, DC operating conditions, and  
capacitance for 1.8-V APEX 20KC devices.  
Operating  
Conditions  
Table 17. APEX 20KC Device Absolute Maximum Ratings  
Note (1)  
Symbol Parameter Conditions  
Min  
Max  
Unit  
VCCINT Supply voltage  
VCCIO  
With respect to ground (2)  
–0.5  
–0.5  
–0.5  
–25  
–65  
–65  
2.5  
4.6  
4.6  
25  
V
V
VI  
DC input voltage  
V
IOUT  
TSTG  
TAMB  
TJ  
DC output current, per pin  
Storage temperature  
Ambient temperature  
Junction temperature  
mA  
° C  
° C  
° C  
No bias  
150  
135  
135  
Under bias  
PQFP, RQFP, TQFP, and BGA  
packages, under bias  
Ceramic PGA packages, under bias  
150  
° C  
54  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 18. APEX 20KC Device Recommended Operating Conditions  
Symbol Parameter Conditions  
Min  
Max  
Unit  
VCCINT Supply voltage for internal logic  
and input buffers  
(3), (4)  
1.71  
(1.71)  
1.89  
(1.89)  
V
VCCIO  
Supply voltage for output buffers, (3), (4)  
3.3-V operation  
3.00  
(3.00)  
3.60  
(3.60)  
V
V
V
Supply voltage for output buffers, (3), (4)  
2.5-V operation  
2.375  
(2.375)  
2.625  
(2.625)  
Supply voltage for output buffers, (3), (4)  
1.71  
1.89  
1.8-V operation  
(1.71)  
(1.89)  
VI  
Input voltage  
(2), (5)  
–0.5  
0
4.1  
VCCIO  
85  
V
V
VO  
TJ  
Output voltage  
Operating junction temperature  
For commercial use  
For industrial use  
0
° C  
° C  
ns  
ns  
–40  
100  
40  
tR  
tF  
Input rise time (10% to 90%)  
Input fall time (90% to 10%)  
40  
Table 19. APEX 20KC Device DC Operating Conditions  
Symbol Parameter Conditions  
Notes (6), (7)  
Min  
Typ  
Max  
Unit  
II  
Input pin leakage current (8) VI = 3.6 to 0.0 V  
–10  
–10  
10  
10  
µA  
µA  
IOZ  
Tri-stated I/O pin leakage  
VO = 4.1 to –0.5 V  
current (8)  
ICC0  
VCC supply current (standby) VI = ground, no load,  
10  
5
mA  
mA  
(All ESBs in power-down  
mode)  
no toggling inputs,  
-7 speed grade  
VI = ground, no load,  
no toggling inputs,  
-8, -9 speed grades  
RCONF Value of I/O pin pull-up  
resistor before and during  
configuration  
VCCIO = 3.0 V (9)  
20  
30  
60  
50  
80  
kΩ  
kΩ  
kΩ  
VCCIO = 2.375 V (9)  
V
CCIO = 1.71 V (9)  
150  
1
DC operating specifications on APEX 20KC I/O standards are  
listed in Tables 21 to 35.  
Altera Corporation  
55  
APEX 20KC Programmable Logic Device Data Sheet  
Table 20. APEX 20KC Device Capacitance  
Note (10)  
Conditions  
Symbol  
Parameter  
Min  
Max  
Unit  
CIN  
Input capacitance  
VIN = 0 V, f = 1.0 MHz  
8
pF  
pF  
CINCLK Input capacitance on  
dedicated clock pin  
VIN = 0 V, f = 1.0 MHz  
12  
COUT  
Output capacitance  
VOUT = 0 V, f = 1.0 MHz  
8
pF  
Notes to Tables 17 through 20:  
(1) See the Operating Requirements for Altera Devices Data Sheet.  
(2) Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 4.6 V for input  
currents less than 100 mA and time periods shorter than 20 ns.  
(3) Numbers in parentheses are for industrial-temperature-range devices.  
(4) Maximum VCC rise time is 100 ms, and VCC must rise monotonically.  
(5) All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before VCCINT and VCCIO are  
powered.  
(6) Typical values are for TA = 25° C, VCCINT = 1.8 V, and VCCIO = 1.8 V, 2.5 V or 3.3 V.  
(7) These values are specified under the APEX 20KC device recommended operating conditions, shown in Table 18 on  
page 55.  
(8) This value is specified for normal device operation. The value may vary during power-up.  
(9) Pin pull-up resistance values will be lower if an external source drives the pin higher than VCCIO  
(10) Capacitance is sample-tested only.  
.
Tables 21 through 35 list the DC operating specifications for the supported  
I/O standards. These tables list minimal specifications only; APEX 20KC  
devices may exceed these specifications.  
Table 21. LVTTL I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Maximum  
Units  
VCCIO  
Output supply  
voltage  
3.0  
3.6  
V
VIH  
VIL  
II  
High-level input  
voltage  
2.0  
–0.3  
–10  
2.4  
VCCIO + 0.3  
V
V
Low-level input  
voltage  
0.8  
10  
Input pin leakage  
current  
VIN = 0 V or 3.3 V  
IOH = –12 mA,  
µA  
V
VOH  
VOL  
High-level output  
voltage  
V
CCIO = 3.0 V (1)  
IOL = 12 mA,  
CCIO = 3.0 V (2)  
Low-level output  
voltage  
0.4  
V
V
56  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 22. LVCMOS I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Maximum  
Units  
VCCIO  
Power supply  
voltage range  
3.0  
3.6  
V
VIH  
VIL  
II  
High-level input  
voltage  
2.0  
–0.3  
VCCIO + 0.3  
V
V
Low-level input  
voltage  
0.8  
10  
Input pin leakage  
current  
VIN = 0 V or 3.3 V  
VCCIO = 3.0 V  
–10  
µA  
V
VOH  
VOL  
High-level output  
voltage  
VCCIO – 0.2  
I
OH = –0.1 mA (1)  
Low-level output  
voltage  
VCCIO = 3.0 V  
0.2  
V
I
OL = 0.1 mA (2)  
Table 23. 2.5-V I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Maximum  
Units  
VCCIO  
Output supply  
voltage  
2.375  
2.625  
V
VIH  
VIL  
II  
High-level input  
voltage  
1.7  
–0.3  
–10  
VCCIO + 0.3  
V
V
Low-level input  
voltage  
0.8  
10  
Input pin leakage  
current  
VIN = 0 V or 3.3 V  
µA  
VOH  
High-level output  
voltage  
IOH = –0.1 mA (1)  
2.1  
2.0  
1.7  
V
V
V
V
V
V
I
OH = –1 mA (1)  
IOH = –2 mA (1)  
IOL = 0.1 mA (2)  
IOL = 1 mA (2)  
VOL  
Low-level output  
voltage  
0.2  
0.4  
0.7  
I
OL = 2 mA (2)  
Altera Corporation  
57  
APEX 20KC Programmable Logic Device Data Sheet  
Table 24. 1.8-V I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Maximum  
Units  
VCCIO  
Output supply  
voltage  
1.7  
1.9  
V
VIH  
VIL  
II  
High-level input  
voltage  
0.65 × VCCIO  
VCCIO + 0.3  
0.35 × VCCIO  
10  
V
V
Low-level input  
voltage  
Input pin leakage  
current  
VIN = 0 V or 3.3 V  
IOH = –2 mA (1)  
IOL = 2 mA (2)  
–10  
µA  
V
VOH  
VOL  
High-level output  
voltage  
VCCIO – 0.45  
Low-level output  
voltage  
0.45  
V
Table 25. 3.3-V PCI Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
3.0  
3.3  
3.6  
V
V
VIH  
VIL  
II  
High-level input  
voltage  
0.5 × VCCIO  
VCCIO + 0.5  
Low-level input  
voltage  
–0.5  
–10  
0.3 × VCCIO  
V
µA  
V
Input pin leakage  
current  
0 < VIN < VCCIO  
IOUT = –500 µA  
IOUT = 1,500 µA  
10  
VOH  
VOL  
High-level output  
voltage  
0.9 × VCCIO  
Low-level output  
voltage  
0.1 × VCCIO  
V
58  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 26. 3.3-V PCI-X Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
Output supply  
voltage  
3.0  
3.3  
3.6  
V
VIH  
VIL  
High-level input  
voltage  
0.5 × VCCIO  
VCCIO + 0.5  
V
V
Low-level input  
voltage  
–0.5  
0.35 × VCCIO  
VIPU  
IIL  
Input pull-up voltage  
0.7 × VCCIO  
V
Input pin leakage  
current  
0 < VIN < VCCIO  
IOUT = –500 µA  
IOUT = 1,500 µA  
–10.0  
10.0  
µA  
VOH  
VOL  
Lpin  
High-level output  
voltage  
0.9 × VCCIO  
V
V
Low-level output  
voltage  
0.1 × VCCIO  
Pin Inductance  
15.0  
nH  
Table 27. 3.3-V LVDS I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
3.135  
250  
3.3  
3.465  
650  
V
VOD  
Differential output  
voltage  
RL = 100 Ω  
RL = 100 Ω  
mV  
VOD  
Change in VOD  
between high and  
low  
50  
mV  
VOS  
Output offset voltage RL = 100 Ω  
1.125  
1.25  
1.375  
50  
V
VOS  
Change in VOS  
between high and  
low  
RL = 100 Ω  
mV  
VTH  
VIN  
RL  
Differential input  
threshold  
VCM = 1.2 V  
–100  
0.0  
100  
2.4  
mV  
V
Receiver input  
voltage range  
Receiver differential  
input resistor  
90  
100  
110  
(external to APEX  
devices)  
Altera Corporation  
59  
APEX 20KC Programmable Logic Device Data Sheet  
Table 28. GTL+ I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VTT  
Termination voltage  
Reference voltage  
1.35  
0.88  
1.5  
1.0  
1.65  
1.12  
V
V
V
VREF  
VIH  
High-level input  
voltage  
VREF + 0.1  
VIL  
Low-level input  
voltage  
VREF – 0.1  
0.65  
V
V
VOL  
Low-level output  
voltage  
IOL = 36 mA (2)  
Table 29. SSTL-2 Class I Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Termination voltage  
Reference voltage  
2.375  
VREF – 0.04  
1.15  
2.5  
2.625  
VREF + 0.04  
1.35  
V
V
V
V
VTT  
VREF  
VIH  
VREF  
1.25  
High-level input  
voltage  
VREF + 0.18  
VCCIO + 0.3  
VIL  
Low-level input  
voltage  
–0.3  
VREF – 0.18  
V
V
V
VOH  
VOL  
High-level output  
voltage  
IOH = –7.6 mA (1)  
IOL = 7.6 mA (2)  
VTT + 0.57  
Low-level output  
voltage  
VTT – 0.57  
60  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 30. SSTL-2 Class II Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Termination voltage  
Reference voltage  
2.375  
VREF – 0.04  
1.15  
2.5  
2.625  
VREF + 0.04  
1.35  
V
V
V
V
VTT  
VREF  
VIH  
VREF  
1.25  
High-level input  
voltage  
VREF + 0.18  
VCCIO + 0.3  
VIL  
Low-level input  
voltage  
–0.3  
VREF – 0.18  
V
V
V
VOH  
VOL  
High-level output  
voltage  
IOH = –15.2 mA (1)  
IOL = 15.2 mA (2)  
VTT + 0.76  
Low-level output  
voltage  
VTT – 0.76  
Table 31. SSTL-3 Class I Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Termination voltage  
Reference voltage  
3.0  
3.3  
VREF  
1.5  
3.6  
V
V
V
V
VTT  
VREF  
VIH  
VREF – 0.05  
1.3  
VREF + 0.05  
1.7  
High-level input  
voltage  
VREF + 0.2  
VCCIO + 0.3  
VIL  
Low-level input  
voltage  
–0.3  
VREF – 0.2  
V
V
V
VOH  
VOL  
High-level output  
voltage  
IOH = –8 mA (1)  
IOL = 8 mA (2)  
VTT + 0.6  
Low-level output  
voltage  
VTT – 0.6  
Altera Corporation  
61  
APEX 20KC Programmable Logic Device Data Sheet  
Table 32. SSTL-3 Class II Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Termination voltage  
Reference voltage  
3.0  
3.3  
VREF  
1.5  
3.6  
V
V
V
V
VTT  
VREF  
VIH  
VREF – 0.05  
1.3  
VREF + 0.05  
1.7  
High-level input  
voltage  
VREF + 0.2  
VCCIO + 0.3  
VIL  
Low-level input  
voltage  
–0.3  
VREF – 0.2  
V
V
V
VOH  
VOL  
High-level output  
voltage  
IOH = –16 mA (1)  
IOL = 16 mA (2)  
VTT + 0.8  
Low-level output  
voltage  
VTT – 0.8  
Table 33. HSTL Class I I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Termination voltage  
Reference voltage  
1.71  
VREF – 0.05  
0.68  
1.8  
1.89  
V
V
V
V
VTT  
VREF  
VIH  
VREF  
0.75  
VREF + 0.05  
0.90  
High-level input  
voltage  
VREF + 0.1  
VCCIO + 0.3  
VIL  
Low-level input  
voltage  
–0.3  
VREF – 0.1  
V
V
V
VOH  
VOL  
High-level output  
voltage  
IOH = –8 mA (1)  
IOL = 8 mA (2)  
VCCIO – 0.4  
Low-level output  
voltage  
0.4  
62  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 34. 3.3-V AGP I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
I/O supply voltage  
Reference voltage  
3.15  
3.3  
3.45  
V
V
V
VREF  
VIH  
0.39 × VCCIO  
0.5 × VCCIO  
0.41 × VCCIO  
VCCIO + 0.5  
High-level input  
voltage  
VIL  
VOH  
VOL  
II  
Low-level input  
voltage  
0.3 × VCCIO  
3.6  
V
V
High-level output  
voltage  
IOUT = –500 µA  
IOUT = 1,500 µA  
0 < VIN < VCCIO  
0.9 × VCCIO  
Low-level output  
voltage  
0.1 × VCCIO  
10  
V
Input pin leakage  
current  
–10  
µA  
Table 35. CTT I/O Specifications  
Symbol  
Parameter  
Conditions  
Minimum  
Typical  
Maximum  
Units  
VCCIO  
TT/VREF (3)  
I/O supply voltage  
3.0  
3.3  
1.5  
3.6  
V
V
V
Termination and  
reference voltage  
1.35  
1.65  
VIH  
VIL  
II  
High-level input  
voltage  
VREF + 0.2  
V
V
Low-level input  
voltage  
VREF – 0.2  
10  
Input pin leakage  
current  
0 < VIN < VCCIO  
IOH = –8 mA (1)  
IOL = 8 mA (2)  
–10  
µA  
V
VOH  
VOL  
IO  
High-level output  
voltage  
VREF + 0.4  
Low-level output  
voltage  
VREF – 0.4  
10  
V
Output leakage  
current (when output  
is high Z)  
GND VOUT VCCIO  
–10  
µA  
Notes to Tables 21 through 35:  
(1) The IOH parameter refers to high-level output current.  
(2) The IOL parameter refers to low-level output current. This parameter applies to open-drain pins as well as output  
pins.  
(3) VREF specifies center point of switching range.  
Figure 31 shows the output drive characteristics of APEX 20KC devices.  
Altera Corporation  
63  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 31. Output Drive Characteristics of APEX 20KC Devices  
Note (1)  
60  
120  
110  
55  
50  
I
I
OL  
OL  
100  
90  
45  
40  
35  
30  
25  
20  
15  
10  
5
V
V
= 1.8 V  
CCINT  
= 3.3 V  
V
V
= 1.8 V  
= 2.5V  
CCINT  
CCIO  
80  
70  
CCIO  
Typical I  
Output  
Current (mA)  
Typical I  
Output  
O
O
Room Temperature  
Room Temperature  
Current (mA)  
60  
50  
40  
30  
20  
10  
I
I
OH  
OH  
0.5  
1
1.5  
Vo Output Voltage (V)  
2
3
2
2.5  
3
0.5  
1
1.5  
2.5  
Vo Output Voltage (V)  
26  
24  
I
OL  
22  
20  
18  
Typical I  
Output  
Current (mA)  
V
V
= 1.8V  
= 1.8V  
O
CCINT  
CCIO  
16  
14  
12  
10  
8
Room Temperature  
6
I
OH  
4
2
1.5  
Vo Output Voltage (V)  
0.5  
1
2.0  
Note to Figure 31:  
(1) These are transient (AC) currents.  
64  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
The high-performance FastTrack and MegaLAB interconnect routing  
resources ensure predictable performance, accurate simulation, and  
accurate timing analysis. This predictable performance contrasts with that  
of FPGAs, which use a segmented connection scheme and therefore have  
unpredictable performance.  
Timing Model  
Figure 32 shows the fMAX timing model for APEX 20KC devices.  
Figure 32. fMAX Timing Model  
LE  
t
SU  
H
Routing Delay  
t
t
t
t
F1—4  
t
CO  
F5—20  
t
LUT  
F20+  
ESB  
t
ESBARC  
t
t
t
t
t
t
t
t
ESBSRC  
ESBAWC  
ESBSWC  
ESBWASU  
ESBWDSU  
ESBSRASU  
ESBWESU  
ESBDATASU  
t
t
t
t
ESBWADDRSU  
ESBRADDRSU  
ESBDATACO1  
ESBDATACO2  
t
t
t
t
ESBDD  
PD  
PTERMSU  
PTERMCO  
Figures 33 and 34 show the asynchronous and synchronous  
timingwaveforms, respectively, for the ESB macroparameters in Table 37.  
Altera Corporation  
65  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 33. ESB Asynchronous Timing Waveforms  
ESB Asynchronous Read  
RE  
Rdaddress  
Data-Out  
a0  
a1  
a2  
a3  
tESBARC  
d0  
d1  
d2  
d3  
ESB Asynchronous Write  
WE  
tESBWP  
tESBWDSU  
tESBWDH  
din0  
din1  
Data-In  
tESBWASU  
tESBWAH  
tESBWCCOMB  
a0  
a1  
a2  
Wraddress  
Data-Out  
tESBDD  
din0  
din1  
dout2  
66  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 34. ESB Synchronous Timing Waveforms  
ESB Synchronous Read  
WE  
Rdaddress  
CLK  
a0  
a1  
a2  
a3  
tESBDATASU  
tESBDATAH  
tESBARC  
tESBDATACO2  
Data-Out  
d1  
d2  
d3  
ESB Synchronous Write (ESB Output Registers Used)  
WE  
din1  
din2  
a2  
din3  
a3  
Data-In  
a0  
a1  
a2  
Wraddress  
tESBWESU  
tESBDATAH  
tESBWEH  
tESBDATASU  
CLK  
tESBDATACO1  
tESBSWC  
dout0  
dout1  
din1  
din2  
din3  
din2  
Data-Out  
Figure 35 shows the timing model for bidirectional I/O pin timing.  
Altera Corporation  
67  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 35. Synchronous Bidirectional Pin External Timing  
OE Register (1)  
PRN  
tXZBIDIR  
tZXBIDIR  
D
Q
Dedicated  
Clock  
CLRN  
tOUTCOBIDIR  
Output IOE Register  
PRN  
Bidirectional Pin  
D
Q
tINSUBIDIR  
tINHBIDIR  
CLRN  
Input Register (1), (2)  
PRN  
D
Q
CLRN  
Notes to Figure 35:  
(1) The output enable and input registers are LE registers in the LAB adjacent to the  
bidirectional pin. Use the “Output Enable Routing = Single-Pin” option in the  
Quartus II software to set the output enable register.  
(2) Use the “Decrease Input Delay to Internal Cells = OFF” option in the Quartus II  
software to set the LAB-adjacent input register. This maintains a zero hold time for  
LAB-adjacent registers while giving a fast, position-independent setup time. Set  
“Decrease Input Delay to Internal Cells = ON” and move the input register farther  
away from the bidirectional pin for a faster setup time with zero hold time. The  
exact position where zero hold occurs with the minimum setup time varies with  
device density and speed grade.  
Tables 36 to 38 describes the fMAX timing parameters shown in Figure 32.  
Table 39 describes the functional timing parameters.  
Table 36. APEX 20KC fMAX LE Timing Parameters  
Symbol  
Parameter  
tSU  
tH  
tCO  
tLUT  
LE register setup time before clock  
LE register hold time before clock  
LE register clock-to-output delay  
LUT delay for data-in to data-out  
68  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 37. APEX 20KC fMAX ESB Timing Parameters  
Symbol  
Parameter  
tESBARC  
ESB asynchronous read cycle time  
tESBSRC  
ESB synchronous read cycle time  
tESBAWC  
ESB asynchronous write cycle time  
tESBSWC  
ESB synchronous write cycle time  
tESBWASU  
tESBWAH  
tESBWDSU  
tESBWDH  
tESBRASU  
tESBRAH  
ESB write address setup time with respect to WE  
ESB write address hold time with respect to WE  
ESB data setup time with respect to WE  
ESB data hold time with respect to WE  
ESB read address setup time with respect to RE  
ESB read address hold time with respect to RE  
ESB WE setup time before clock when using input register  
ESB data setup time before clock when using input register  
ESB write address setup time before clock when using input registers  
ESB read address setup time before clock when using input registers  
ESB clock-to-output delay when using output registers  
ESB clock-to-output delay without output registers  
ESB data-in to data-out delay for RAM mode  
ESB macrocell input to non-registered output  
ESB macrocell register setup time before clock  
ESB macrocell register clock-to-output delay  
tESBWESU  
tESBDATASU  
tESBWADDRSU  
tESBRADDRSU  
tESBDATACO1  
tESBDATACO2  
tESBDD  
tPD  
tPTERMSU  
tPTERMCO  
Table 38. APEX 20KC fMAX Routing Delays  
Symbol  
Parameter  
tF1-4  
Fan-out delay estimate using local interconnect  
Fan-out delay estimate using MegaLab interconnect  
Fan-out delay estimate using FastTrack interconnect  
tF5-20  
tF20+  
Altera Corporation  
69  
APEX 20KC Programmable Logic Device Data Sheet  
Table 39. APEX 20KC Minimum Pulse Width Timing Parameters  
Symbol  
Parameter  
tCH  
Minimum clock high time from clock pin  
Minimum clock low time from clock pin  
LE clear pulse width  
tCL  
tCLRP  
tPREP  
tESBCH  
tESBCL  
tESBWP  
tESBRP  
LE preset pulse width  
Clock high time  
Clock low time  
Write pulse width  
Read pulse width  
Tables 40 and 41 describe APEX 20KC external timing parameters. The  
timing values for these pin-to-pin delays are reported for all pins using the  
3.3-V LVTTL I/O standard.  
Table 40. APEX 20KC External Timing Parameters  
Note (1)  
Symbol  
Clock Parameter  
Conditions  
tINSU  
tINH  
Setup time with global clock at IOE register  
Hold time with global clock at IOE register  
tOUTCO  
Clock-to-output delay with global clock at IOE output register  
Setup time with PLL clock at IOE input register  
Hold time with PLL clock at IOE input register  
Clock-to-output delay with PLL clock at IOE output register  
(2)  
(2)  
tINSUPLL  
tINHPLL  
tOUTCOPLL  
70  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 41. APEX 20KC External Bidirectional Timing Parameters  
Symbol Parameter  
Note (1)  
Condition  
tINSUBIDIR  
Setup time for bidirectional pins with global clock at LAB-adjacent input  
register  
tINHBIDIR  
Hold time for bidirectional pins with global clock at LAB-adjacent input  
register  
tOUTCOBIDIR  
Clock-to-output delay for bidirectional pins with global clock at IOE  
register  
(2)  
tXZBIDIR  
Synchronous output enable register to output buffer disable delay  
Synchronous output enable register to output buffer enable delay  
(2)  
(2)  
tZXBIDIR  
tINSUBIDIRPLL  
Setup time for bidirectional pins with PLL clock at LAB-adjacent input  
register  
tINHBIDIRPLL  
Hold time for bidirectional pins with PLL clock at LAB-adjacent input  
register  
tOUTCOBIDIRPLL  
tXZBIDIRPLL  
Clock-to-output delay for bidirectional pins with PLL clock at IOE register (2)  
Synchronous output enable register to output buffer disable delay with  
PLL  
(2)  
tZXBIDIRPLL  
Synchronous output enable register to output buffer enable delay with  
PLL  
(2)  
Notes to Tables 40 and 41:  
(1) These timing parameters are sample-tested only.  
(2) For more information, refer to Table 43.  
Tables 42 and 43 define the timing delays for each I/O standard. Some  
output standards require test load circuits for AC timing measurements as  
shown in Figures 36 through 38.  
Table 42. APEX 20KC Selectable I/O Standard Input Adder Delays (Part 1 of 2)  
Note (1)  
Condition  
Symbol  
Parameter  
LVCMOS  
Input adder delay for the LVCMOS I/O standard  
Input adder delay for the LVTTL I/O standard  
Input adder delay for the 2.5-V I/O standard  
LVTTL  
2.5 V  
1.8 V  
Input adder delay for the 1.8-V I/O standard  
PCI  
Input adder delay for the PCI I/O standard  
GTl+  
Input adder delay for the GTL+ I/O standard  
Input adder delay for the SSTL-3 Class I I/O standard  
Input adder delay for the SSTL-3 Class II I/O standard  
Input adder delay for the SSTL -2 Class I I/O standard  
Input adder delay for the SSTL -2 Class II I/O standard  
SSTL-3 Class I  
SSTL-3 Class II  
SSTL-2 Class I  
SSTL-2 Class II  
Altera Corporation  
71  
APEX 20KC Programmable Logic Device Data Sheet  
Table 42. APEX 20KC Selectable I/O Standard Input Adder Delays (Part 2 of 2)  
Note (1)  
Condition  
Symbol  
Parameter  
LVDS  
CTT  
Input adder delay for the LVDS I/O standard  
Input adder delay for the CTT I/O standard  
Input adder delay for the AGP I/O standard  
AGP  
Table 43. APEX 20KC Selectable I/O Standard Output Adder Delays  
Symbol Parameter  
Note (1)  
Condition  
LVCMOS  
Output adder delay for the LVCMOS I/O standard  
Output adder delay for the LVTTL I/O standard  
LVTTL  
2.5 V  
1.8 V  
PCI  
Cload = 35 pF  
Rup = 564.5 Ω  
Rdn = 430 (2)  
Output adder delay for the 2.5-V I/O standard  
Output adder delay for the 1.8-V I/O standard  
Output adder delay for the PCI I/O standard  
Output adder delay for the GTL+ I/O standard  
Cload = 35 pF  
Rup = 450 Ω  
Rdn = 450 (2)  
Cload = 35 pF  
Rup = 520 Ω  
Rdn = 480 (2)  
Cload = 10 pF  
Rup = 1M Ω  
Rdn = 25 (2)  
GTl+  
Cload = 30 pF  
Rup = 25 (2)  
SSTL-3 Class I  
Output adder delay for the SSTL-3 Class I I/O standard Cload1 = 0 pF  
Cload2 = 30 pF  
R = 25 (2)  
SSTL-3 Class II  
Output adder delay for the SSTL-3 Class II I/O standard Cload1 = 0 pF  
Cload2 = 30 pF  
R = 25 (2)  
SSTL-2 Class I  
SSTL-2 Class II  
LVDS  
Output adder delay for the SSTL-2 Class I I/O standard  
Output adder delay for the SSTL-2 Class II I/O standard  
Output adder delay for the LVDS I/O standard  
Cload = 4 pF  
R=100 (2)  
CTT  
AGP  
Output adder delay for the CTT I/O standard  
Output adder delay for the AGP I/O standard  
Note to Tables 42 and 43:  
(1) These delays report the differences in delays for different I/O standards. Add the delay for the I/O standard that  
is used to the external timing parameters.  
(2) See Figure 36 for more information.  
72  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 36. AC Test Conditions for LVTTL, 2.5 V, 1.8 V, PCI & GTL+ I/O Standards  
VCCIO  
Rup  
Ouptut pin  
Cload  
Rdn  
Figure 37. AC Test Conditions for SSTL-3 Class I & II I/O Standards  
VCCIO  
R
Output pin  
R
Cload2  
Cload1  
Figure 38. AC Test Conditions for the LVDS I/O Standard  
Positive  
Output pin  
R
Cload  
Negative  
Output pin  
Altera Corporation  
73  
APEX 20KC Programmable Logic Device Data Sheet  
Tables 44 through 67 show the fMAX and external timing parameters for  
EPC20K200C, EP20K400C, EP20K600C, and EP20K1000C devices.  
Table 44. EP20K200C fMAX LE Timing Microparameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tSU  
tH  
tCO  
tLUT  
0.01  
0.10  
0.01  
0.10  
0.01  
0.10  
ns  
ns  
ns  
ns  
0.27  
0.65  
0.30  
0.78  
0.32  
0.92  
Table 45. EP20K200C fMAX ESB Timing Microparameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tESBARC  
1.30  
2.35  
2.92  
3.05  
1.51  
2.49  
3.46  
3.44  
1.69  
2.72  
3.86  
3.85  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tESBSRC  
tESBAWC  
tESBSWC  
tESBWASU  
tESBWAH  
tESBWDSU  
tESBWDH  
tESBRASU  
tESBRAH  
0.45  
0.44  
0.57  
0.44  
1.25  
0.00  
0.00  
2.01  
–0.20  
0.02  
0.50  
0.50  
0.63  
0.50  
1.43  
0.03  
0.00  
2.27  
–0.24  
0.00  
0.54  
0.55  
0.68  
0.55  
1.56  
0.11  
0.00  
2.45  
–0.28  
–0.02  
tESBWESU  
tESBDATASU  
tESBWADDRSU  
tESBRADDRSU  
tESBDATACO1  
tESBDATACO2  
tESBDD  
1.09  
2.10  
2.50  
1.48  
1.28  
2.52  
2.97  
1.78  
1.43  
2.82  
3.32  
2.00  
tPD  
tPTERMSU  
tPTERMCO  
0.58  
0.72  
0.81  
1.10  
1.29  
1.45  
74  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 46. EP20K200C fMAX Routing Delays  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tF1-4  
0.15  
0.81  
0.98  
0.17  
0.94  
1.13  
0.20  
1.12  
1.35  
ns  
ns  
ns  
tF5-20  
tF20+  
Table 47. EP20K200C Minimum Pulse Width Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tCH  
1.33  
1.33  
0.20  
0.20  
1.33  
1.33  
1.05  
0.87  
1.66  
1.66  
0.20  
0.20  
1.66  
1.66  
1.28  
1.06  
2.00  
2.00  
0.20  
0.20  
2.00  
2.00  
1.44  
1.19  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tCL  
tCLRP  
tPREP  
tESBCH  
tESBCL  
tESBWP  
tESBRP  
Table 48. EP20K200C External Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSU  
1.23  
0.00  
2.00  
0.81  
0.00  
0.50  
1.26  
0.00  
2.00  
0.92  
0.00  
0.50  
1.33  
ns  
ns  
ns  
ns  
ns  
ns  
tINH  
0.00  
tOUTCO  
tINSUPLL  
tINHPLL  
tOUTCOPLL  
3.79  
2.36  
4.31  
2.62  
2.00  
4.70  
-
-
-
-
Altera Corporation  
75  
APEX 20KC Programmable Logic Device Data Sheet  
Table 49. EP20K200C External Bidirectional Timing Parameters  
Symbol  
-7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSUBIDIR  
1.38  
0.00  
2.00  
1.78  
0.00  
2.00  
1.99  
0.00  
2.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tINHBIDIR  
tOUTCOBIDIR  
tXZBIDIR  
3.79  
6.12  
6.12  
4.31  
6.51  
6.51  
4.70  
7.89  
7.89  
tZXBIDIR  
tINSUBIDIRPLL  
tINHBIDIRPLL  
tOUTCOBIDIRPLL  
tXZBIDIRPLL  
tZXBIDIRPLL  
2.82  
0.00  
0.50  
3.47  
0.00  
0.50  
-
-
-
2.36  
4.69  
4.69  
2.62  
4.82  
4.82  
-
-
-
Table 50. EP20K400C fMAX LE Timing Parameters  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tSU  
tH  
tCO  
tLUT  
0.01  
0.10  
0.01  
0.10  
0.01  
0.10  
ns  
ns  
ns  
ns  
0.27  
0.65  
0.30  
0.78  
0.32  
0.92  
76  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 51. EP20K400C fMAX ESB Timing Parameters  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tESBARC  
1.30  
2.35  
2.92  
3.05  
1.51  
2.49  
3.46  
3.44  
1.69  
2.72  
3.86  
3.85  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tESBSRC  
tESBAWC  
tESBSWC  
tESBWASU  
tESBWAH  
tESBWDSU  
tESBWDH  
tESBRASU  
tESBRAH  
0.45  
0.44  
0.57  
0.44  
1.25  
0.00  
0.00  
2.01  
0.20  
0.02  
0.50  
0.50  
0.63  
0.50  
1.43  
0.03  
0.00  
2.27  
0.24  
0.00  
0.54  
0.55  
0.68  
0.55  
1.56  
0.11  
0.00  
2.45  
0.28  
0.02  
tESBWESU  
tESBDATASU  
tESBWADDRSU  
tESBRADDRSU  
tESBDATACO1  
tESBDATACO2  
tESBDD  
1.09  
2.10  
2.50  
1.48  
1.28  
2.52  
2.97  
1.78  
1.43  
2.82  
3.32  
2.00  
tPD  
tPTERMSU  
tPTERMCO  
0.58  
0.72  
0.81  
1.10  
1.29  
1.45  
Table 52. EP20K400C fMAX Routing Delays  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tF1-4  
0.15  
0.94  
1.73  
0.17  
1.06  
1.96  
0.19  
1.25  
2.30  
ns  
ns  
ns  
tF5-20  
tF20+  
Altera Corporation  
77  
APEX 20KC Programmable Logic Device Data Sheet  
Table 53. EP20K400C Minimum Pulse Width Timing Parameters  
Symbol  
-7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tCH  
1.33  
1.33  
0.20  
0.20  
1.33  
1.33  
1.05  
0.87  
1.66  
1.66  
0.20  
0.20  
1.66  
1.66  
1.28  
1.06  
2.00  
2.00  
0.20  
0.20  
2.00  
2.00  
1.44  
1.19  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tCL  
tCLRP  
tPREP  
tESBCH  
tESBCL  
tESBWP  
tESBRP  
Table 54. EP20K400C External Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSU  
1.37  
0.00  
2.00  
0.80  
0.00  
0.50  
1.52  
0.00  
2.00  
0.91  
0.00  
0.50  
1.64  
ns  
ns  
ns  
ns  
ns  
ns  
tINH  
0.00  
tOUTCO  
tINSUPLL  
tINHPLL  
tOUTCOPLL  
4.25  
2.27  
4.61  
2.55  
2.00  
5.03  
-
-
-
-
78  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 55. EP20K400C External Bidirectional Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
Min Max  
-9 Speed Grade  
Min Max  
Unit  
Min  
Max  
tINSUBIDIR  
1.29  
0.00  
2.00  
1.67  
0.00  
2.00  
1.92  
0.00  
2.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tINHBIDIR  
tOUTCOBIDIR  
tXZBIDIR  
4.25  
6.55  
6.55  
4.61  
6.97  
6.97  
5.03  
7.35  
7.36  
tZXBIDIR  
tINSUBIDIRPLL  
tINHBIDIRPLL  
tOUTCOBIDIRPLL  
tXZBIDIRPLL  
tZXBIDIRPLL  
3.22  
0.00  
0.50  
3.80  
0.00  
0.50  
-
-
-
2.27  
4.62  
4.62  
2.55  
4.84  
4.84  
-
-
-
Table 56. EP20K600C fMAX LE Timing Parameters  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tSU  
tH  
tCO  
tLUT  
0.01  
0.10  
0.01  
0.10  
0.01  
0.10  
ns  
ns  
ns  
ns  
0.27  
0.65  
0.30  
0.78  
0.32  
0.92  
Altera Corporation  
79  
APEX 20KC Programmable Logic Device Data Sheet  
Table 57. EP20K600C fMAX ESB Timing Parameters  
Symbol  
-7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tESBARC  
1.30  
2.35  
2.92  
3.05  
1.51  
2.49  
3.46  
3.44  
1.69  
2.72  
3.86  
3.85  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tESBSRC  
tESBAWC  
tESBSWC  
tESBWASU  
tESBWAH  
tESBWDSU  
tESBWDH  
tESBRASU  
tESBRAH  
0.45  
0.44  
0.57  
0.44  
1.25  
0.00  
0.00  
2.01  
0.20  
0.02  
0.50  
0.50  
0.63  
0.50  
1.43  
0.03  
0.00  
2.27  
0.24  
0.00  
0.54  
0.55  
0.68  
0.55  
1.56  
0.11  
0.00  
2.45  
0.28  
0.02  
tESBWESU  
tESBDATASU  
tESBWADDRSU  
tESBRADDRSU  
tESBDATACO1  
tESBDATACO2  
tESBDD  
1.09  
2.10  
2.50  
1.48  
1.28  
2.52  
2.97  
1.78  
1.43  
2.82  
3.32  
2.00  
tPD  
tPTERMSU  
tPTERMCO  
0.58  
0.72  
0.81  
1.10  
1.29  
1.45  
Table 58. EP20K600C fMAX Routing Delays  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tF1-4  
0.15  
0.94  
1.76  
0.16  
1.05  
1.98  
0.18  
1.20  
2.23  
ns  
ns  
ns  
tF5-20  
tF20+  
80  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 59. EP20K600C Minimum Pulse Width Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tCH  
1.33  
1.33  
0.20  
0.20  
1.33  
1.33  
1.05  
0.87  
1.66  
1.66  
0.20  
0.20  
1.66  
1.66  
1.28  
1.06  
2.00  
2.00  
0.20  
0.20  
2.00  
2.00  
1.44  
1.19  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tCL  
tCLRP  
tPREP  
tESBCH  
tESBCL  
tESBWP  
tESBRP  
Table 60. EP20K600C External Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSU  
1.28  
0.00  
2.00  
0.80  
0.00  
0.50  
1.40  
0.00  
2.00  
0.91  
0.00  
0.50  
1.45  
ns  
ns  
ns  
ns  
ns  
ns  
tINH  
0.00  
tOUTCO  
tINSUPLL  
tINHPLL  
tOUTCOPLL  
4.29  
2.37  
4.77  
2.63  
2.00  
5.11  
-
-
-
-
Altera Corporation  
81  
APEX 20KC Programmable Logic Device Data Sheet  
Table 61. EP20K600C External Bidirectional Timing Parameters  
Symbol  
-7 Speed Grade  
-8 Speed Grade  
Min Max  
-9 Speed Grade  
Min Max  
Unit  
Min  
Max  
tINSUBIDIR  
2.03  
0.00  
2.00  
2.57  
0.00  
2.00  
2.97  
0.00  
2.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tINHBIDIR  
tOUTCOBIDIR  
tXZBIDIR  
4.29  
8.31  
8.31  
4.77  
9.14  
9.14  
5.11  
9.76  
9.76  
tZXBIDIR  
tINSUBIDIRPLL  
tINHBIDIRPLL  
tOUTCOBIDIRPLL  
tXZBIDIRPLL  
tZXBIDIRPLL  
3.99  
0.00  
0.50  
4.77  
0.00  
0.50  
-
-
-
2.37  
6.35  
6.35  
2.63  
6.94  
6.94  
-
-
-
Table 62. EP20K1000C fMAX LE Timing Microparameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tSU  
tH  
tCO  
tLUT  
0.01  
0.10  
0.01  
0.10  
0.01  
0.10  
ns  
ns  
ns  
ns  
0.27  
0.66  
0.30  
0.79  
0.32  
0.92  
82  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 63. EP20K1000C fMAX ESB Timing Microparameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tESBARC  
1.48  
2.36  
2.93  
3.08  
1.57  
2.50  
3.46  
3.43  
1.65  
2.73  
3.86  
3.83  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tESBSRC  
tESBAWC  
tESBSWC  
tESBWASU  
tESBWAH  
tESBWDSU  
tESBWDH  
tESBRASU  
tESBRAH  
0.51  
0.38  
0.62  
0.38  
1.40  
0.00  
0.00  
1.92  
–0.20  
0.00  
0.50  
0.51  
0.62  
0.51  
1.47  
0.07  
0.00  
2.19  
–0.28  
–0.03  
0.52  
0.57  
0.66  
0.57  
1.53  
0.18  
0.00  
2.35  
–0.32  
–0.05  
tESBWESU  
tESBDATASU  
tESBWADDRSU  
tESBRADDRSU  
tESBDATACO1  
tESBDATACO2  
tESBDD  
1.12  
2.11  
2.56  
1.49  
1.30  
2.53  
2.96  
1.79  
1.46  
2.84  
3.30  
2.02  
tPD  
tPTERMSU  
tPTERMCO  
0.61  
0.69  
0.77  
1.13  
1.32  
1.48  
Table 64. EP20K1000C fMAX Routing Delays  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tF1-4  
0.15  
1.13  
2.30  
0.17  
1.31  
2.71  
0.19  
1.50  
3.19  
ns  
ns  
ns  
tF5-20  
tF20+  
Altera Corporation  
83  
APEX 20KC Programmable Logic Device Data Sheet  
Table 65. EP20K1000C Minimum Pulse Width Timing Parameters  
Symbol  
-7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tCH  
1.33  
1.33  
0.20  
0.20  
1.33  
1.33  
1.04  
0.87  
1.66  
1.66  
0.20  
0.20  
1.66  
1.66  
1.26  
1.05  
2.00  
2.00  
0.20  
0.20  
2.00  
2.00  
1.41  
1.18  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tCL  
tCLRP  
tPREP  
tESBCH  
tESBCL  
tESBWP  
tESBRP  
Table 66. EP20K1000C External Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSU  
1.14  
0.00  
2.00  
0.81  
0.00  
0.50  
1.14  
0.00  
2.00  
0.92  
0.00  
0.50  
1.11  
ns  
ns  
ns  
ns  
ns  
ns  
tINH  
0.00  
tOUTCO  
tINSUPLL  
tINHPLL  
tOUTCOPLL  
4.63  
2.32  
5.26  
2.55  
2.00  
5.69  
-
-
-
-
84  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Table 67. EP20K1000C External Bidirectional Timing Parameters  
Symbol -7 Speed Grade -8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Max  
Min  
Max  
Min  
Max  
tINSUBIDIR  
1.86  
0.00  
2.00  
2.54  
0.00  
2.00  
3.15  
0.00  
2.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tINHBIDIR  
tOUTCOBIDIR  
tXZBIDIR  
4.63  
8.98  
8.98  
5.26  
9.89  
9.89  
5.69  
10.67  
10.67  
tZXBIDIR  
tINSUBIDIRPLL  
tINHBIDIRPLL  
tOUTCOBIDIRPLL  
tXZBIDIRPLL  
tZXBIDIRPLL  
4.17  
0.00  
0.50  
5.27  
0.00  
0.50  
-
-
-
2.32  
6.67  
6.67  
2.55  
7.18  
7.18  
-
-
-
Tables 68 and 69 show selectable I/O standard input and output delays  
for APEX 20KC devices. If you select an I/O standard input or output  
delay other than LVCMOS, add the delay for the selected speed grade to  
the LVCMOS value.  
Table 68. Selectable I/O Standard Input Delays  
Symbol -7 Speed Grade  
-8 Speed Grade  
-9 Speed Grade  
Unit  
Min  
Min  
Max  
Min  
Max  
Min  
Max  
LVCMOS  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
LVTTL  
2.5 V  
0.00  
0.00  
0.00  
1.8 V  
0.04  
0.11  
0.14  
PCI  
0.00  
0.04  
0.03  
GTL+  
–0.30  
–0.19  
–0.19  
–0.19  
–0.19  
–0.19  
0.00  
0.25  
0.23  
SSTL-3 Class I  
SSTL-3 Class II  
SSTL-2 Class I  
SSTL-2 Class II  
LVDS  
–0.13  
–0.13  
–0.13  
–0.13  
–0.17  
0.00  
–0.13  
–0.13  
–0.13  
–0.13  
–0.16  
0.00  
CTT  
AGP  
0.00  
0.00  
0.00  
Altera Corporation  
85  
APEX 20KC Programmable Logic Device Data Sheet  
Table 69. Selectable I/O Standard Output Delays  
Symbol  
-7 Speed Grade  
-8 Speed Grad  
Min Max  
-9 Speed Grade  
Unit  
Min  
Min  
Max  
Min  
Max  
LVCMOS  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
LVTTL  
2.5 V  
0.00  
0.00  
0.00  
1.8 V  
1.18  
1.41  
1.57  
PCI  
–0.52  
–0.18  
–0.67  
–0.67  
–0.67  
–0.67  
–0.69  
0.00  
–0.53  
–0.29  
–0.71  
–0.71  
–0.71  
–0.71  
–0.70  
0.00  
–0.56  
–0.39  
–0.75  
–0.75  
–0.75  
–0.75  
–0.73  
0.00  
GTL+  
SSTL-3 Class I  
SSTL-3 Class II  
SSTL-2 Class I  
SSTL-2 Class II  
LVDS  
CTT  
AGP  
0.00  
0.00  
0.00  
To estimate device power consumption, use the interactive power  
estimator on the Altera web site at http://www.altera.com.  
Power  
Consumption  
The APEX 20KC architecture supports several configuration schemes.  
This section summarizes the device operating modes and available device  
configuration schemes.  
Configuration&  
Operation  
Operating Modes  
The APEX architecture uses SRAM configuration elements that require  
configuration data to be loaded each time the circuit powers up. The  
process of physically loading the SRAM data into the device is called  
configuration. During initialization, which occurs immediately after  
configuration, the device resets registers, enables I/O pins, and begins to  
operate as a logic device. The I/O pins are tri-stated during power-up,  
and before and during configuration. Together, the configuration and  
initialization processes are called command mode; normal device operation  
is called user mode.  
Before and during device configuration, all I/O pins are pulled to VCCIO  
by a built-in weak pull-up resistor.  
86  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
SRAM configuration elements allow APEX 20KC devices to be  
reconfigured in-circuit by loading new configuration data into the device.  
Real-time reconfiguration is performed by forcing the device into  
command mode with a device pin, loading different configuration data,  
reinitializing the device, and resuming user-mode operation. In-field  
upgrades can be performed by distributing new configuration files.  
Configuration Schemes  
The configuration data for an APEX 20KC device can be loaded with one  
of five configuration schemes (see Table 70), chosen on the basis of the  
target application. An EPC16, EPC2, or EPC1 configuration device,  
intelligent controller, or the JTAG port can be used to control the  
configuration of an APEX 20KC device. When a configuration device is  
used, the system can configure automatically at system power-up.  
Multiple APEX 20KC devices can be configured in any of five  
configuration schemes by connecting the configuration enable (nCE) and  
configuration enable output (nCEO) pins on each device.  
Table 70. Data Sources for Configuration  
Configuration Scheme  
Data Source  
Configuration device  
EPC16, EPC8, EPC4, EPC2, or EPC1 configuration device  
MasterBlaster or ByteBlasterMV download cable or serial data source  
Parallel data source  
Passive serial (PS)  
Passive parallel asynchronous (PPA)  
Passive parallel synchronous (PPS)  
JTAG  
Parallel data source  
MasterBlaster or ByteBlasterMV download cable or a microprocessor  
with a Jam Standard Test and Programming Language (STAPL) or  
JBC File  
For more information on configuration, see Application Note 116  
(Configuring SRAM-Based LUT Devices).  
f
See the Altera web site (http://www.altera.com) or the Altera Digital  
Library for pin-out information.  
Device Pin-  
Outs  
Figure 39 describes the ordering codes for Stratix devices. For more  
information on a specific package, refer to the Altera Device Package  
Information Data Sheet.  
Ordering  
Information  
Altera Corporation  
87  
APEX 20KC Programmable Logic Device Data Sheet  
Figure 39. APEX 20KC Device Packaging Ordering Information  
EP20K  
1000C  
F
1020  
C
7
ES  
Family Signature  
Optional Suffix  
EP20K: APEX 20K  
Indicates specific device options or  
shipment method.  
ES: Engineering sample  
Device Type  
200C  
400C  
600C  
1000C  
Speed Grade  
7, 8, or 9, with 7 being the fastest  
Package Type  
Operating Temperature  
Q: Plastic quad flat package (PQFP)  
B: Ball-grid array (BGA)  
F: FineLine BGA  
C: Commercial temperature (t = 0˚ C to 85˚ C)  
J
I: Industrial temperature (t = -40˚ C to 100˚ C)  
J
Pin Count  
Number of pins for a particular package  
The information contained in the APEX 20KC Programmable Logic Device  
Data Sheet version 2.2 supersedes information published in previous  
versions.  
Revision  
History  
Version 2.2  
The following changes were made to the APEX 20KC Programmable Logic  
Device Data Sheet version 2.2:  
Updated Tables 1.  
Updated notes in Tables 20.  
Version 2.1  
The following changes were made to the APEX 20KC Programmable Logic  
Device Data Sheet version 2.1:  
Removed figure on AC Test Conditions.  
Updated conditions in Tables 40 and 41.  
Added Tables 42 and 43.  
Updated VOD in Table 27.  
Added Figures 36 through 38.  
Updated Tables 44 through 49.  
Updated Tables 62 through 67.  
Removed notes in Tables 44 through 67.  
Various textual changes throughout the document.  
88  
Altera Corporation  
APEX 20KC Programmable Logic Device Data Sheet  
Altera Corporation  
89  
APEX 20KC Programmable Logic Device Data Sheet  
®
101 Innovation Drive  
San Jose, CA 95134  
(408) 544-7000  
http://www.altera.com  
Applications Hotline:  
(800) 800-EPLD  
Customer Marketing:  
(408) 544-7104  
Copyright © 2002 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the  
stylized Altera logo, specific device designations, and all other words and logos that are identified as  
trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera  
Corporation in the U.S. and other countries. All other product or service names are the property of their  
respective holders. Altera products are protected under numerous U.S. and foreign patents and pending  
applications, mask work rights, and copyrights. Altera warrants performance of its semiconductor products  
to current specifications in accordance with Altera’s standard warranty, but reserves the  
right to make changes to any products and services at any time without notice. Altera  
assumes no responsibility or liability arising out of the application or use of any  
information, product, or service described herein except as expressly agreed to in writing  
by Altera Corporation. Altera customers are advised to obtain the latest version of device  
specifications before relying on any published information and before placing orders for  
products or services.  
Literature Services:  
lit_req@altera.com  
90  
Altera Corporation  
Literature  
Licensing  
Download  
Buy On-Line  
Entire Site  
|
|
|
|
|
|
|
Corporate Buy On-Line  
Home  
Products  
Support  
System Solutions  
Technology Center  
Education & Events  
Results For: EP20K200C  
13 part numbers found and 0 obsolete part numbers found  
APEX 20KC Device Family (1.8V, LVDS, Copper)  
APEX 20KC Datasheet  
Part Number Format  
APEX 20K Literature  
Buying Altera Devices  
Part Number  
Device  
Pin & Package Temperature Speeds Options  
EP20K200CB356C7 EP20K200C 356 pin BGA  
Commercial  
( 0 to 85°C)  
7, 8, 9  
7, 8, 9  
None  
None  
EP20K200CB356C8  
EP20K200CB356C9  
Pinout  
EP20K200CF484C7 EP20K200C 484 pin FBGA Commercial  
EP20K200CF484C8  
EP20K200CF484C9  
Pinout  
( 0 to 85°C)  
EP20K200CF484I8 EP20K200C 484 pin FBGA Industrial  
8
None  
None  
Pinout  
( -40 to 100°C)  
EP20K200CQ208C7 EP20K200C 208 pin PQFP Commercial  
7, 8, 9  
EP20K200CQ208C8  
EP20K200CQ208C9  
Pinout  
( 0 to 85°C)  
EP20K200CQ240C7 EP20K200C 240 pin PQFP Commercial  
7, 8, 9  
None  
EP20K200CQ240C8  
EP20K200CQ240C9  
Pinout  
( 0 to 85°C)  
Search  
EP20K200C  
Advanced Help  
Please Give Us Feedback  
Sign Up for E-mail Updates  
Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line  
Contact Us | New User | Site Map | Privacy | Legal Notice  
Copyright © 1995-2004 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA  
Literature  
Licensing  
Download  
Buy On-Line  
Entire Site  
|
|
|
|
|
|
|
Corporate Buy On-Line  
Home  
Products  
Support  
System Solutions  
Technology Center  
Education & Events  
Results For: EP20K600C  
11 part numbers found and 0 obsolete part numbers found  
APEX 20KC Device Family (1.8V, LVDS, Copper)  
APEX 20KC Datasheet  
Part Number Format  
APEX 20K Literature  
Buying Altera Devices  
Part Number  
Device  
Pin & Package Temperature Speeds Options  
EP20K600CB652C7 EP20K600C 652 pin BGA  
Commercial  
( 0 to 85°C)  
7, 8, 9  
None  
EP20K600CB652C8  
EP20K600CB652C9  
Pinout  
EP20K600CB652I8 EP20K600C 652 pin BGA  
Pinout  
Industrial  
( -40 to 100°C)  
8
None  
None  
EP20K600CF33C7 EP20K600C 1020 pin FBGA Commercial  
7, 8, 9  
EP20K600CF33C8  
EP20K600CF33C9  
Pinout  
( 0 to 85°C)  
EP20K600CF672C7 EP20K600C 672 pin FBGA Commercial  
7, 8, 9  
8
None  
None  
EP20K600CF672C8  
EP20K600CF672C9  
Pinout  
( 0 to 85°C)  
EP20K600CF672I8 EP20K600C 672 pin FBGA Industrial  
Pinout ( -40 to 100°C)  
Search  
EP20K600C  
Advanced Help  
Please Give Us Feedback  
Sign Up for E-mail Updates  
Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line  
Contact Us | New User | Site Map | Privacy | Legal Notice  
Copyright © 1995-2004 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA  
Literature  
Licensing  
Download  
Buy On-Line  
Entire Site  
|
|
|
|
|
|
|
Corporate Buy On-Line  
Home  
Products  
Support  
System Solutions  
Technology Center  
Education & Events  
Results For: EP20K400C  
6 part numbers found and 0 obsolete part numbers found  
APEX 20KC Device Family (1.8V, LVDS, Copper)  
APEX 20KC Datasheet  
Part Number Format  
APEX 20K Literature  
Buying Altera Devices  
Part Number  
Device  
Pin & Package Temperature Speeds Options  
EP20K400CB652C7 EP20K400C 652 pin BGA  
Commercial  
( 0 to 85°C)  
7, 8, 9  
7, 8, 9  
None  
None  
EP20K400CB652C8  
EP20K400CB652C9  
Pinout  
EP20K400CF672C7 EP20K400C 672 pin FBGA Commercial  
EP20K400CF672C8  
EP20K400CF672C9  
Pinout  
( 0 to 85°C)  
Search  
EP20K400C  
Advanced Help  
Please Give Us Feedback  
Sign Up for E-mail Updates  
Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line  
Contact Us | New User | Site Map | Privacy | Legal Notice  
Copyright © 1995-2004 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA  
Literature  
Licensing  
Download  
Buy On-Line  
Entire Site  
|
|
|
|
|
|
|
Corporate Buy On-Line  
Home  
Products  
Support  
System Solutions  
Technology Center  
Education & Events  
Results For: EP20K1000C  
10 part numbers found and 0 obsolete part numbers found  
APEX 20KC Device Family (1.8V, LVDS, Copper)  
APEX 20KC Datasheet  
Part Number Format  
APEX 20K Literature  
Buying Altera Devices  
Part Number  
Device  
Pin & Package Temperature Speeds Options  
EP20K1000CB652C7 EP20K1000C 652 pin BGA  
Commercial  
( 0 to 85°C)  
7, 8, 9  
7, 8, 9  
7, 8, 9  
8
None  
None  
None  
None  
EP20K1000CB652C8  
EP20K1000CB652C9  
Pinout  
EP20K1000CF33C7 EP20K1000C 1020 pin FBGA Commercial  
EP20K1000CF33C8  
EP20K1000CF33C9  
Pinout  
( 0 to 85°C)  
EP20K1000CF672C7 EP20K1000C 672 pin FBGA Commercial  
EP20K1000CF672C8  
EP20K1000CF672C9  
Pinout  
( 0 to 85°C)  
EP20K1000CF33I8  
EP20K1000C 1020 pin FBGA Industrial  
Pinout ( -40 to 100°C)  
Search  
EP20K1000C  
Advanced Help  
Please Give Us Feedback  
Sign Up for E-mail Updates  
Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line  
Contact Us | New User | Site Map | Privacy | Legal Notice  
Copyright © 1995-2004 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA  

相关型号:

EP20K600E

Programmable Logic Device Family
ALTERA

EP20K600EBC652-3V

Field Programmable Gate Array
ALTERA

EP20K600EBC652XES

Loadable PLD, PBGA652, 45 X 45 MM, 1.27 MM PITCH, BGA-652
ALTERA

EP20K600EBI652-3V

Field Programmable Gate Array
ALTERA