SE7210TP1-E [INTEL]

Intel? Server Board Technical Product Specification; 英特尔?服务器主板产品技术规格
SE7210TP1-E
型号: SE7210TP1-E
厂家: INTEL    INTEL
描述:

Intel? Server Board Technical Product Specification
英特尔?服务器主板产品技术规格

服务器
文件: 总145页 (文件大小:2186K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Intel® Server Board  
SE7210TP1-E  
Technical Product Specification  
Intel order number C49240-002  
Revision 2.0  
October 2004  
Enterprise Platforms and Services Marketing  
Intel® Server Board SE7210TP1-E TPS  
Revision History  
Revision History  
Date  
Revision  
Number  
Modifications  
February 2004  
October 2004  
1.0  
2.0  
Initial Release.  
Updated BIOS information to be consistent with latest BIOS release.  
This product specification applies to the Intel® Server Board SE7210TP1-E with BIOS identifier  
SE7210TP P04.10.  
Changes to this specification will be published in the Intel Server Board SE7210TP1-E  
Specification Update before being incorporated into a revision of this document.  
ii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Disclaimers  
Disclaimers  
Information in this document is provided in connection with Intel® products. No license, express  
or implied, by estoppel or otherwise, to any intellectual property rights is granted by this  
document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel  
assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to  
sale and/or use of Intel products including liability or warranties relating to fitness for a particular  
purpose, merchantability, or infringement of any patent, copyright or other intellectual property  
right. Intel products are not intended for use in medical, life saving, or life sustaining  
applications. Intel may make changes to specifications and product descriptions at any time,  
without notice.  
The Intel® Server Board Intel® Server Board SE7210TP1-E may contain design defects or  
errors known as errata which may cause the product to deviate from published specifications.  
Current characterized errata are available on request.  
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.  
*Other brands and names may be claimed as the property of others.  
Copyright © Intel Corporation 2003 - 2004.  
iii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
This page intentionally left blank  
iv  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
Table of Contents  
1. Introduction ..........................................................................................................................1  
1.1  
1.2  
Chapter Outline........................................................................................................1  
Server Board Use Disclaimer ..................................................................................2  
2. Server Board Overview........................................................................................................3  
2.1  
2.2  
SE7210TP1-E SKU Availability ...............................................................................3  
SE7210TP1-E Feature Set......................................................................................3  
3. Functional Architecture.......................................................................................................7  
3.1  
3.1.1  
Processor Subsystem..............................................................................................7  
Reset Configuration Logic .......................................................................................8  
Processor Support...................................................................................................8  
Microcode ................................................................................................................9  
Processor Cache .....................................................................................................9  
Hyper-Threading Technology ..................................................................................9  
Intel E7210 Chipset .................................................................................................9  
Intel 827210 Memory Controller Hub (MCH) ...........................................................9  
Intel 82802AC 8 Megabit Firmware Hub (FWH) ....................................................10  
PCI-X .....................................................................................................................10  
Low Profile Riser Slot ............................................................................................10  
SMBus Interface ....................................................................................................11  
6300ESB I/O Controller Hub..................................................................................11  
PCI Interface..........................................................................................................11  
IDE Interface..........................................................................................................12  
Serial ATA (SATA) Controller ................................................................................12  
3.1.2  
3.1.3  
3.1.4  
3.1.5  
3.2  
3.2.1  
3.2.2  
3.2.3  
3.2.4  
3.2.5  
3.2.6  
3.2.7  
3.2.8  
3.2.9  
3.2.10 Low Pin Count (LPC) Interface..............................................................................13  
3.2.11 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller).....13  
3.2.12 Advanced Programmable Interrupt Controller (APIC)............................................13  
3.2.13 Universal Serial Bus (USB) Controller...................................................................13  
3.2.14 Real Time Clock, CMOS SRAM, and Battery........................................................14  
3.2.15 GPIO......................................................................................................................15  
3.2.16 Enhanced Power Management .............................................................................15  
3.2.17 System Management Bus (SMBus 2.0).................................................................15  
3.3  
Memory Subsystem...............................................................................................15  
v
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
3.3.1  
3.4  
Memory Configurations..........................................................................................17  
I/O Sub-System .....................................................................................................22  
PCI Sub-System ....................................................................................................22  
DMA Channels.......................................................................................................24  
Interrupts................................................................................................................24  
PCI Interrupt Routing Map.....................................................................................25  
SCSI Support.........................................................................................................26  
IDE Support ...........................................................................................................30  
SATA Support........................................................................................................30  
Video Controller.....................................................................................................31  
Network Interface Controller (NIC) Subsystem......................................................32  
3.4.1  
3.4.2  
3.4.3  
3.4.4  
3.4.5  
3.4.6  
3.4.7  
3.4.8  
3.4.9  
3.4.10 USB 2.0 Support....................................................................................................35  
3.4.11 I/O Controller .........................................................................................................35  
3.5  
Configuration and Initialization...............................................................................36  
Memory Space.......................................................................................................36  
I/O Map..................................................................................................................37  
Clock Generation and Distribution.........................................................................39  
3.5.1  
3.5.2  
3.6  
4. System BIOS.......................................................................................................................40  
4.1  
4.2  
4.2.1  
4.2.2  
4.3  
4.3.1  
4.3.2  
4.4  
4.5  
4.6  
4.7  
4.7.1  
4.8  
4.8.1  
BIOS Identification String.......................................................................................43  
Flash ROM.............................................................................................................44  
Removable Media Support ....................................................................................44  
Legacy USB...........................................................................................................44  
Resource Configuration.........................................................................................45  
PCI Autoconfiguration............................................................................................45  
PCI IDE Support ....................................................................................................45  
System Management BIOS (SMBIOS)..................................................................45  
BIOS Updates........................................................................................................46  
Recovering BIOS Data ..........................................................................................46  
BIOS POST ...........................................................................................................47  
User Interface ........................................................................................................47  
BIOS Setup Utility..................................................................................................48  
Localization............................................................................................................48  
Keyboard Commands............................................................................................48  
Entering BIOS Setup .............................................................................................49  
Menu Selection......................................................................................................49  
4.8.2  
4.8.3  
4.8.4  
vi  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
4.8.5  
4.8.6  
4.8.7  
4.8.8  
BOOT menu...........................................................................................................60  
Security Menu........................................................................................................63  
Server Menu ..........................................................................................................64  
Exit Menu...............................................................................................................68  
Operating System Boot, Sleep and Wake .............................................................69  
Microsoft* Windows* Compatibility ........................................................................69  
Advanced Configuration and Power Interface (ACPI) ...........................................69  
Sleep and Wake Functionality ...............................................................................69  
Security..................................................................................................................72  
4.9  
4.9.1  
4.9.2  
4.9.3  
4.10  
4.10.1 Administrator/User Passwords and F2 Setup Usage Model..................................72  
4.10.2 Password Clear Jumper ........................................................................................74  
5. Platform Management Architecture..................................................................................75  
5.1  
5.1.1  
Essential Management Features and Functionality...............................................75  
Overview of National* Semiconductor PC87431 Integrated Management Controller75  
National Semiconductor PC87431 integrated management controller Self-test....76  
SMBus Interfaces ..................................................................................................76  
External Interface to National Semiconductor PC87431 integrated management  
5.1.2  
5.1.3  
5.1.4  
controller...............................................................................................................................76  
5.1.5  
5.1.6  
5.1.7  
5.1.8  
5.1.9  
Messaging Interfaces.............................................................................................77  
Direct Platform Control (IPMI over LAN)................................................................80  
Wake On LAN / Power On LAN and Magic Packet Support..................................82  
Watchdog Timer ....................................................................................................83  
System Event Log (SEL) .......................................................................................83  
5.1.10 Sensor Data Record (SDR) Repository.................................................................84  
5.1.11 Event Message Reception.....................................................................................84  
5.1.12 Event Filtering and Alerting....................................................................................84  
5.1.13 NMI Generation .....................................................................................................88  
5.1.14 SMI Generation......................................................................................................89  
5.2  
Platform Management Interconnects.....................................................................89  
Power Supply Interface Signals.............................................................................89  
System Reset Control............................................................................................91  
Temperature-based Fan Speed Control................................................................92  
Front Panel Control................................................................................................93  
Secure Mode Operation.........................................................................................96  
FRU Information ....................................................................................................97  
5.2.1  
5.2.2  
5.2.3  
5.2.4  
5.2.5  
5.2.6  
vii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
5.2.7  
5.3  
5.3.1  
LCD Support..........................................................................................................97  
Sensors..................................................................................................................98  
Sensor Type Codes...............................................................................................98  
6. Error Reporting and Handling.........................................................................................102  
6.1  
6.1.1  
6.1.2  
6.1.3  
6.2  
6.2.1  
6.2.2  
6.3  
Error Sources and Types.....................................................................................102  
PCI Bus Errors.....................................................................................................102  
Processor Bus Errors...........................................................................................102  
Memory Bus Errors..............................................................................................102  
BIOS Error Messages, POST Codes, and BIOS Beep Codes ............................102  
BIOS Error Messages..........................................................................................103  
Port 80h POST Codes.........................................................................................105  
Bus Initialization Checkpoints..............................................................................110  
7. Connector Pin-Outs and Jumper Blocks .......................................................................112  
7.1  
7.2  
7.3  
7.4  
7.5  
7.6  
7.7  
7.8  
Power Connectors ...............................................................................................112  
PCI Bus Connectors ............................................................................................113  
Front Panel Connector.........................................................................................114  
VGA Connector....................................................................................................115  
NIC /USB Connector............................................................................................115  
SATA/SATA RAID Connectors............................................................................116  
6300ESB I/O IDE Connectors .............................................................................117  
Front Panel USB Header.....................................................................................117  
Floppy Connector ................................................................................................118  
Serial Port Connector ..........................................................................................118  
Keyboard and Mouse Connector.........................................................................119  
Miscellaneous Headers .......................................................................................120  
7.9  
7.10  
7.11  
7.12  
7.12.1 Fan Headers........................................................................................................120  
7.13  
System Recovery and Update Jumper ................................................................120  
Clear CMOS Jumper ...........................................................................................121  
PASSWORD Jumper...........................................................................................121  
Write protected Jumper .......................................................................................121  
7.14  
7.15  
7.16  
8. Environmental Specifications.........................................................................................123  
8.1  
8.2  
8.3  
Absolute Maximum Ratings.................................................................................123  
SE7210TP1-E Power Budget ..............................................................................123  
Product Regulatory Compliance..........................................................................124  
Product Safety Compliance .................................................................................124  
8.3.1  
viii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Table of Contents  
8.3.2  
8.3.3  
8.4  
Product EMC Compliance ...................................................................................124  
Product Regulatory Compliance Markings ..........................................................125  
Electromagnetic Compatibility Notices ................................................................125  
FCC (USA)...........................................................................................................125  
INDUSTRY CANADA (ICES-003)........................................................................126  
Europe (CE Declaration of Conformity) ...............................................................126  
Taiwan Declaration of Conformity........................................................................126  
Korean RRL Compliance.....................................................................................127  
Australia / New Zealand.......................................................................................127  
Replacing the Back-Up Battery............................................................................127  
Calculated Mean Time Between Failures (MTBF)...............................................128  
Mechanical Specifications ...................................................................................129  
8.4.1  
8.4.2  
8.4.3  
8.4.4  
8.4.5  
8.4.6  
8.5  
8.6  
8.7  
Appendix A: Glossary of Terms ............................................................................................130  
ix  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
List of Figures  
List of Figures  
Figure 1. Intel Server Board SE7210TP1-E Diagram ...................................................................5  
Figure 2. Intel Server Board SE7210TP1-E Mechanical Drawing ................................................6  
Figure 3. Intel E7210 Chipset Block Diagram.............................................................................10  
Figure 4. USB Port Configuration ...............................................................................................14  
Figure 5. Examples of Dual Channel Configuration with Dynamic Mode....................................18  
Figure 6. Example of Dual Channel Configuration without Dynamic Mode ................................19  
Figure 7. Examples of Single Channel Configuration with Dynamic Mode.................................20  
Figure 8. Examples of Single Channel Configuration without Dynamic Mode............................21  
Figure 9. LAN Connector LED Locations....................................................................................34  
Figure 10: National Semiconductor PC87431 integrated management controller in a Server  
Management System ...........................................................................................................75  
Figure 11: External Interfaces to National Semiconductor PC87431 integrated management  
controller...............................................................................................................................77  
Figure 12 - IPMI-over-LAN..........................................................................................................81  
Figure 13: Power Supply Control Signals ...................................................................................89  
Figure 14. Intel Server Board SE7210TP1-E I/O Shield Drawing.............................................129  
x
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
List of Tables  
List of Tables  
Table 1. Processor Support Matrix ...............................................................................................8  
Table 2. Supported Memory Configurations ...............................................................................16  
Table 3. Supported System Bus Frequency and Memory Speed Combinations........................16  
Table 4. Characteristics of Dual/Single Channel Configuration with/without Dynamic Mode .....17  
Table 5: PCI Bus Segment Characteristics.................................................................................22  
Table 6. DMA Channels..............................................................................................................24  
Table 7. Interrupts.......................................................................................................................24  
Table 8. PCI Interrupt Routing Map ............................................................................................25  
Table 9: Video Modes.................................................................................................................32  
Table 10. 10/100 Ethernet LAN Connector LEDs.......................................................................34  
Table 11. 10/100/1000 LAN Connector LED States ...................................................................34  
Table 12. System Memory Map..................................................................................................36  
Table 13. PCI Configuration Space Map ....................................................................................37  
Table 14. I/O Map .......................................................................................................................37  
Table 15. PCI Bus Configuration IDs..........................................................................................39  
Table 16: Supported BIOS Features...........................................................................................40  
Table 17: BIOS Setup Keyboard Command Bar Options ...........................................................48  
Table 18: BIOS Setup Main Menu Options.................................................................................50  
Table 19. Advanced Menu..........................................................................................................50  
Table 20. CPU Configuration Submenu......................................................................................51  
Table 21. IDE Configuration Submenu .......................................................................................52  
Table 22. Primary/Secondary/Third/Fourth Master/Slave Submenu...........................................53  
Table 23. Primary/Secondary/Third/Fourth Master/Slave Submenu...........................................54  
Table 24. Primary/Secondary/Third/Fourth Master/Slave Submenu...........................................54  
Table 25. Primary/Secondary/Third/Fourth Master/Slave Submenu...........................................55  
Table 26. Primary/Secondary/Third/Fourth Master/Slave Submenu...........................................55  
Table 27. Floppy Configuration Submenu ..................................................................................56  
Table 28. Super I/O Configuration Submenu..............................................................................57  
Table 29. USB Configuration Submenu......................................................................................58  
Table 30. USB Mass Storage Device Configuration Sub-menu Selections................................58  
Table 31. PCI Configuration Submenu .......................................................................................59  
Table 32. Boot Features .............................................................................................................60  
xi  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
List of Tables  
Table 33. Boot Settings Configuration Submenu........................................................................60  
Table 34. Boot Device Priority Submenu....................................................................................61  
Table 35. Boot Disk Drives Submenu........................................................................................62  
Table 36. Removable Drives Submenu ......................................................................................62  
Table 37. CD/DVD Drives Submenu...........................................................................................63  
Table 38. Security Menu.............................................................................................................63  
Table 39. Server Menu ...............................................................................................................64  
Table 40. System Managment Submenu....................................................................................66  
Table 41. Serial Console Features Submenu.............................................................................67  
Table 42. Event Log Configuration Submenu.............................................................................68  
Table 43. Exit Menu....................................................................................................................68  
Table 44: Supported Wake Events .............................................................................................70  
Table 45. Effects of Pressing the Power Switch .........................................................................71  
Table 46. Power States and Targeted System Power................................................................71  
Table 47: Supported Channel Assigments .................................................................................78  
Table 48: LAN Channel Capacity................................................................................................80  
Table 49: LAN Channel Specifications .......................................................................................81  
Table 50: PEF Action Priorities...................................................................................................86  
Table 51. National Semiconductor PC87431 integrated management controller Factory Default  
Event Filters .........................................................................................................................86  
Table 52: Power Control Initiators...............................................................................................91  
Table 53: System Reset Sources and Actions............................................................................92  
Table 54: Chassis ID LEDs.........................................................................................................94  
Table 55: Fault/Status LED.........................................................................................................95  
Table 56: National Semiconductor PC87431 integrated management controller Built-in Sensors99  
Table 57: SE7520JR2 Platform Sensors for Essentials Management......................................100  
Table 58: POST Error Messages and Handling........................................................................103  
Table 59: POST Code Checkpoints..........................................................................................105  
Table60: Bootblock Initialization Code Checkpoints.................................................................107  
Table61: Bootblock Recovery Code Checkpoints.....................................................................109  
Table62 : POST Error Beep Codes ..........................................................................................110  
Table63 : BIOS Recovery Beep Codes ....................................................................................110  
Table 64. Bus Initialization Checkpoints ...................................................................................110  
Table 65. Upper Nibble High Byte Functions............................................................................110  
Table 66. Lower Nibble High Byte Functions............................................................................111  
xii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
List of Tables  
Table 67. Power Connector Pin-out (J4J1)...............................................................................112  
Table 68. 12V CPU Power Connector (J9B1)...........................................................................112  
Table 69. Auxiliary Signal Connector (J5G2)............................................................................113  
Table 70. PCI Bus Connectors .................................................................................................113  
Table 71. High-Density Front Panel 34-Pin Header Pin Out (J3J4)..........................................114  
Table 72. VGA Connector Pin-out (J7A1).................................................................................115  
Table 73. Magjack Connector (RJ45, 10/100/1000) Pin Out (J6A2).........................................115  
Table 74. Magjack Connector (RJ45, 10/100) Pin Out (J5A1)..................................................116  
Table 75. Triple USB Pin Out (J9A2)........................................................................................116  
Table 76. SATA 7-pin Connectors Pin Out (J3G1, J3G2).........................................................116  
Table 77. 6300ESB I/O IDE 40-pin Connector Pin Out (J4J2, J4J3)........................................117  
Table 78. Front Panel USB Connector Pin-out (J5G1).............................................................117  
Table 79. 34-pin Floppy Connector Pin Out (J3H1)..................................................................118  
Table 80. 9-pin Serial A Port Pin Out (J8A1) ............................................................................118  
Table 81. 10-pin Header Serial B Port Pin Out (J8A2) .............................................................119  
Table 82. Keyboard /Mouse PS/2 Connector Pin Out (J9A1)...................................................119  
Table 83. Three-Pin Fan Headers Pin-Out ...............................................................................120  
Table 84. BIOS Setup Configuration Jumper Settings (J1D1)..................................................120  
Table 85. Clear CMOS Jumper Settings (J1D1).......................................................................121  
Table 86. PASSWORD Jumper Settings (J1D1) ......................................................................121  
Table 87. BIOS WRITE PROTECTED Jumper Settings (J1D1)...............................................122  
Table 88. Absolute Maximum Ratings ......................................................................................123  
Table 89. SE7210TP1-E Power Budget ...................................................................................123  
xiii  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
List of Tables  
This page left intentionally blank.  
xiv  
Revision 2.0  
Introduction  
Intel® Server Board SE7210TP1-E TPS  
1. Introduction  
This Technical Product Specification (TPS) provides detail to the architecture and feature set of  
the Intel® Server Board SE7210TP1-E.  
The target audience for this document is anyone wishing to obtain more in depth detail of the  
server board than what is generally made available in the board’s Users Guide. It is a technical  
document meant to assist people with understanding and learning more about the specific  
features of the board.  
This is one of several technical documents available for this server board. All of the functional  
sub-systems that make up the board are described in this document. However, certain low level  
detail of specific sub-systems is not included. Design level information for specific sub-systems  
can be obtained by ordering the External Product Specification (EPS) for a given sub-system.  
The EPS documents available for this server board include the following:  
Intel® Server Board SE7210TP1-E BIOS External Product Specification  
Intel Server Management Essential Firmware EPS  
These documents are not made publicly available and must be ordered by your local Intel  
representative.  
1.1 Chapter Outline  
This document is divided into the following chapters  
Chapter 1 – Introduction  
Chapter 2 – Product Overview  
Chapter 3 – Board Architecture  
Chapter 4 – System BIOS  
Chapter 5 – Platform Management Architecture  
Chapter 6 – Error Reporting and Handling  
Chapter 7 – Connector Pin-out and Jumper Blocks  
Chapter 8 – Environmental Specifications  
Chapter 9 – Miscellaneous Board Information  
Appendix A – Glossary of Terms  
1
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Introduction  
1.2 Server Board Use Disclaimer  
Intel Corporation server boards contain a number of high-density VLSI and power delivery  
components which need adequate airflow to cool. Intel ensures through its own chassis  
development and testing that when Intel server building blocks are used together, the fully  
integrated system will meet the intended thermal requirements of these components. It is the  
responsibility of the system integrator who chooses not to use Intel developed server building  
blocks to consult vendor datasheets and operating parameters to determine the amount of air  
flow required for their specific application and environmental conditions. Intel Corporation can  
not be held responsible, if components fail or the server board does not operate correctly when  
used outside any of their published operating or non-operating limits.  
2
Revision 2.0  
Server Board Overview  
Intel® Server Board SE7210TP1-E TPS  
2. Server Board Overview  
The Intel® Server Board SE7210TP1-E is a monolithic printed circuit board with features that  
were designed to support the entry server markets.  
2.1 SE7210TP1-E SKU Availability  
In this document, ”SE7210TP1-E” will be used to describe the family of boards that will be made  
available under a common marketing name. The core features for each board will be common;  
however each board will have the following distinctions:  
SE7210TP1:  
Onboard SATA (RAID)  
SE7210TP1SCSI:  
SR1325TP1:  
Onboard SCSI + Onboard SATA (RAID)  
Onboard SATA (RAID) + Low Profile PCI Slot and Riser  
Throughout this document, all references to SE7210TP1-E will refer to all three board SKUs  
unless specifically noted otherwise. The board you select to use may or may not have all the  
features described based on the listed board differences.  
2.2 SE7210TP1-E Feature Set  
The Intel Server Board SE7210TP1-E provides the following feature set:  
o Support for an Intel® Celeron processor or an Intel® Pentium® 4 processor with hyper-  
threading technology in a µPGA478 socket.  
o 400/533/800 MHz Front Side Bus (FSB)  
o Intel® E7210 chipset  
Intel® 827210 Memory Controller Hub (MCH)  
Intel® 6300ESB I/O Controller Hub  
Intel® 82802AC 8 Megabit Firmware Hub (FWH)  
o Support for single-sided or double-sided dual inline memory module (DIMM) double-data  
rate (DDR) memory providing up to 4 GB of system memory with four 184-pin DIMM  
sockets.  
PC3200 (400 MHz): to run 400 MHz memory at full speed requires an Intel Pentium 4  
processor with 800 MHz system bus frequency.  
PC2700 (333 MHz): to run 333 MHz memory at full speed requires an Intel Pentium 4  
processor with 533 MHz system bus frequency.  
Note: PC2700 (333 MHZ) memory will run at 320 MHz frequency when using an Intel  
Pentium 4 processor with 800 MHz system bus frequency.  
PC2100 (266 MHZ): PC2100 (266 MHZ) memory may only be used with an Intel  
Pentium 4 processor with 400 MHz or 533 MHz system bus frequency only.  
o Intel 82547GI Platform LAN Connect (PLC) device for 10/100/1000 Mbits/sec Ethernet LAN  
connectivity  
o Intel 82551QM device for 10/100 Mbits/sec Ethernet LAN connectivity  
3
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Server Board Overview  
o Two independent PCI buses (one 32-bit, 33 MHz, 5 V; one 64-bit, 66 MHz, 3.3V) with four  
PCI connectors and two embedded devices:  
Three PCI-X 64-bit PCI slots  
One 32-bit PCI slot  
Integrated 2D/3D graphics controller: ATI Rage* XL Video Controller with 8 MB of  
SDRAM  
Optional single channel, Ultra 320 SCSI controller (on SE7210TP1SCSI): Adaptec* 7901  
o LPC (Low Pin Count) bus segment with one embedded device: Winbond* W83627HF-AW  
LPC Bus I/O controller chip providing all PC-compatible I/O (floppy, serial, keyboard and  
mouse)  
o Three external USB 2.0 ports on the back panel with an additional internal header, which  
provides support for one additional USB port for front panel support (four total possible USB  
2.0 ports)  
o One serial port and one serial port header  
o Two Serial ATA (SATA) ports provide interface for SATA hard drives and ATAPI devices  
o Two IDE interfaces with Ultra 33, 66 and 100 DMA mode  
o Support for up to six system fans and one processor fan  
o Server System Infrastructure (SSI)-compliant connectors for SSI interface support: front  
panel, power connector  
o Intel Server Management 5.8 support via the National* Semiconductor PC87431 integrated  
management controller  
4
Revision 2.0  
Server Board Overview  
Intel® Server Board SE7210TP1-E TPS  
Figure 1. Intel Server Board SE7210TP1-E Diagram shows the board layout of the server board  
SE7210TP1-E. Each connector and major component is identified by number and identified  
below the figure.  
B D  
A C  
E
F
LIIL  
KHKH  
G
I
H
J
JGJG  
K
IFIF  
L
HEEH  
GDDG  
M
O
Q
N
P
FCFC  
R
S
T
EE  
DD  
CC  
BB  
U
V
AA  
Z Y  
X W  
TP00507  
A: Serial B Header  
B: CPU Fan Header  
C: Sys Fan Header 3  
T: Front Panel Connector  
U: Hot Swap Backplane Header  
V: SCSI LED Header  
D: +12 V CPU Power Connector  
E: Sys Fan Header 4  
F: Processor Socket  
G: DIMM 2B Socket  
W: SATA-A1 Connector  
X: SATA-A2 Connector  
Y: Sys Fan Header 6  
Z: Sys Fan Header 5  
H: DIMM 2A Socket  
AA: Jumper Block  
I: DIMM 1B Socket  
BB: Chassis Intrusion Header  
CC: PCI-X Slot 1, 64/66 RAIDIOS  
DD: PCI-X Slot 2, 64/66  
EE: PCI-X Slot 3, 64/66  
FF: PCI Slot 6, 32/33  
J: DIMM 1A Socket  
K: Sys Fan Header 1  
L: Sys Fan Header 2  
M: Front Panel USB Header  
N: Aux Power Connector  
O: Main Power Connector  
P: Secondary IDE Connector  
Q: Primary IDE Connector  
R: Floppy Connector  
S: Battery  
GG: NIC 2 (10/100 Mbit)  
HH: NIC 1 (1 Gbit)  
II: Video Connector  
JJ: Serial A Connector  
KK: Keyboard and Mouse  
LL: USB Connectors  
Figure 1. Intel Server Board SE7210TP1-E Diagram  
5
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Server Board Overview  
The following mechanical drawing shows the physical dimensions of the baseboard.  
2.82  
2.33  
[ 0.111  
[ 0.092  
]
]
10.16  
0.00  
[ 0.400  
[ 0.000  
]
]
D5A1  
J7A1  
J8A1  
J4A1  
Q4A  
C3A  
6
C
2A  
1
R
3A  
1
R
3A2  
C
3A  
3
R
3A  
3
C
3A  
4
R
3A  
4
C
3A  
5
C
3A  
2
C
3A  
1
J1A1  
1
R
P2A  
1
R5A1  
MH5A1  
J9A2  
M
H
1A  
1
C
R3A  
3A  
7
5
R
P2A  
2
R4A11  
C
7A  
5
C
7A  
6
C7A7  
0.36  
1.62  
14.83  
22.86  
[ 0.014  
[ 0.064  
[ 0.584  
[ 0.900  
]
]
R
4A12  
4A14  
4A15  
4A16  
4A17  
4A18  
4A20  
4A21  
4A23  
4A17  
4A24  
4A25  
4B  
4B  
C6A4  
6A  
R
4A13  
J9A1  
R
R
P2A  
3
R
2
R
R
U1A1  
R5A2  
C7A10  
C7A11  
C7A12  
CR4A1  
R
P2A  
4
C
4A7  
RT6A1  
R
1A  
3
U2A1  
U3B1  
R
R
C5A1  
C5A3  
C
1A5  
C1A6  
J8A2  
J6A2  
R
1A  
4
R
P2A  
5
R4A19  
C5A2  
C5A4  
U4A3  
J5A1  
R
1A  
6
CR4A2  
R
R
C
4A12  
J6A1  
J7A2  
U1A  
2
C7A13  
R
4A22  
R
P2A  
6
R
C
R
C
6A  
5
C
7A14  
R7A6  
CR4A3  
C
6A  
6
U8A1  
R
7A  
8
C7A17  
J7B1  
C4A19  
C
7A16  
CR7B1  
R
7A  
7
R
3A10  
P3B  
3B  
C3B  
3B  
C3B  
R
]
]
R2A12  
C6B1  
D5A2  
D5A3  
U1B1  
C8B2  
R
1
Q5B1  
R
1
C4B  
2
R
2
R
4B  
3
R
5B  
1
R
5B  
2
R
R
R
8B  
8B  
8B  
1
2
3
R
1
C
4B  
3
C4B  
4
MH9B1  
R
2B  
1
R
4B  
5
CR7B3  
C7B  
2
R
2B  
3
C2B  
4
1
R
4B  
6
R2B4  
R2B  
2
R6B1  
CR7B  
R7B1  
C4B6  
R
4B  
7
8
2
R
T7B1  
R
8B  
4
C9B1  
C
5B  
1
R6B  
4
Q9B1  
R
P1B  
1
R
2
U8B1  
D6B  
2
D6B1  
R
4B  
R9B1  
R9B2  
Q2B2  
C5B  
4
2
C4B  
C4B  
4B  
7
C8B5  
R
R
7B  
2
C8B4  
C
8B  
6
R
8B  
6
R
R8B  
8B  
8
7
C
5B  
5
7B  
3
FB3B1  
R3B  
3
8
C4B9  
C
5B  
8
R9B4  
C3B  
6
Q4B  
1
R
T
7B  
2
C7B  
3
R7B4  
C
3B  
3
R3B  
4
C3B4  
Q5B2  
FB3B2  
R
9B  
9B  
9B  
9B  
6
Q8B  
1
U9B  
1
R
9
C5B9  
R6B12  
R
R
C
8
9
4
31.11  
[ 1.225  
]
C
5B12  
5B14  
5B18  
Y3B1  
R
P2B  
1
C5B13  
R
P4B  
1
R
P7B  
1
J6B  
1
C
C8B7  
C8C2  
C
4B11  
R4B10  
U3B  
2
R
6B14  
6B12  
6B15  
Q8B  
2
Q8B  
3
C3B  
9
C
C
7B  
4
C4B13  
Q8B4  
C
RP2B2  
R
P4B  
2
R
7B  
5
R
R
7B  
6
C
4B14  
C
3B11  
R
7B  
7
L7B1  
L9C1  
Q5C  
1
R7B  
8
R3B  
6
C
3B12  
C2C1  
U6C1  
U5B1  
C1C1  
C7C1  
C
C
R
6C  
6C  
6C  
5C  
3
5
1
C8C1  
C
4C  
1
C
4C  
2
L8C1  
C
2C  
6
C
3C  
1
FB  
3C  
1
R
5C  
2
C
1
R
6C  
2
RP4C1  
R
3C1  
R
6C  
3
Y3C1  
R
R6C  
6C  
4
5
R
P2C  
1
C5C4  
C
5C  
2
C
C5C  
5C  
7
3
C
5C  
5
C
1C  
7
C
C
R
4C  
4C  
P4C  
5
7
2
C
5C  
8
C
5C6  
R
4C  
2
C
5C  
9
R
5C  
5
RP1C  
1
C
3C  
5
C5C10  
C
2C  
7
R
4C  
3
R
3C  
8
C5C12  
R
5C  
8
C8C4  
Q8C1  
Q9C2  
Q9C1  
R
R
R
3C  
3C10  
3C12  
3C14  
3C15  
3C17  
3C19  
3C21  
3C23  
3C25  
3C27  
3C28  
3D1  
9
U7C1  
P7C1  
C
3C  
8
RP1C  
2
C5C14  
C5C13  
C
3C  
9
R
P3C  
3C11  
P3C  
1
R
P4C  
3
J6C1  
R
C5C15  
R
C
5C17  
5C18  
C
5C16  
5C  
5C10  
C9C3  
C9D2  
C
L8C2  
C
3C12  
3C13  
3C14  
R
4C  
8
Q5C3  
R
R
R
R
9
Q6C1  
R
3C16  
3C18  
3C20  
3C22  
3C24  
3C26  
3C20  
3D2  
Q5C2  
C
C
RP1C  
3
R
2
R
R
P4C  
4
C
R
R
R
R
C8C6  
C8D1  
C8D3  
C8D6  
R
Q9C3  
C
3C15  
3C16  
3C17  
3C18  
3D1  
3D3  
R
R
P4C  
5
U6C2  
R
2C  
1
C
R
P3C  
3
RP1C  
4
R
R
R
C
R
R
2C  
2
R
1C  
4
U5C1  
C
C
RP4D1  
RP3C4  
RP1D1  
C
C
R
C
RP6D1  
RP2D1  
C3D4  
R5D2  
C
3D5  
3D3  
Q8C2  
Q9C4  
Q9D1  
Q9D2  
RP4D3  
C5D2  
R
P4D2  
R
P1D2  
R
3D2  
R
R2D1  
R
4D1  
C4D1  
C8D2  
R1D1  
mPGA478 SOCKET  
Q5D3  
Q3D1  
R
P4D4  
RP4D5  
C5D5  
C
R
1D1  
U
3D1  
U
3D2  
C9D3  
RP2D2  
C9D4  
C9D6  
R
P1D3  
R
3D6  
3D9  
3D6  
C
4D2  
R
R
3D7  
3D12  
R
R
3D8  
C
1D1  
R
R3D10  
R
3D11  
J6D1  
R1D3  
3D13  
C
C
4D  
3
CR9D1  
RP4D6  
C8D5  
C8D7  
C8D4  
C
R
1D2  
R
P1D4  
R
3D14  
R
5D5  
5D7  
5D6  
5D9  
R3D15  
RP4D7  
Q5D4  
R
C
R
Q5D5  
C9D5  
C4D4  
R5D8  
R1D5  
RP1D5  
C
5D7  
R
1D6  
C
R
1D3  
R
P5D1  
5D10  
5D11  
5D14  
R1D7  
RP4D8  
R
3D16  
3D17  
3D18  
3E  
3E  
C
R
C
R
P1D6  
R1D9  
C
5D12  
C5D13  
R
C
C
C
U3E1  
1
RP4E1  
C
R
1E  
1
2
RP1E1  
C9E1  
C4E1  
R
P4E  
2
C
9E  
5
R
P1E2  
R
P2E1  
RP9E  
1
R
3E  
1
RP4E  
3
Q5E1  
Q5E2  
C8E2  
C8E4  
R
P9E  
2
R
3E  
2
C
4E2  
RP9E3  
J3E1  
C8E3  
R
P9E  
4
CR1E2  
CR1E3  
D4E1  
C5E5  
C4E3  
RP9E  
5
D3E1  
RP2E  
2
FB5E  
1
C9E13  
RP9E  
6
R
P1E  
1E  
P1E  
3
L
5E1  
C8E5  
R
2E1  
C
9E16  
R
4
RP9E  
7
C4E10  
R
4
RP2E  
3
R
1E  
5
Q5E3  
C5F1  
Q5E4  
C5F2  
R
T
7E  
7E  
7E  
1
C
7E  
2
4
7
C1E4  
R
4E  
8
C5E  
5E  
FB5E  
5F1  
7
RP9E8  
R
1
R
7E  
Q7E1  
C8E6  
RP1E  
5
R
3
R
7E  
RP2E  
4
C
8
RP9E  
9
C
C
3E  
3F  
9
1
C
5E  
9
2
C
6E19  
RP9E10  
C
4F  
4F  
4F  
1
R4F  
2
R
5F  
1
R
6F  
1
L
R
1F  
1
R
R1F  
1F  
2
4
R
1F  
3
RP2F  
1
R
P6F  
1
RP1F  
1
U7F1  
C8F  
1
RP9F  
1
3
R
3
R
4F  
4F  
4
R
P9F  
9F  
P9F  
2
R
3F  
1
J4F1  
J4F3  
C
5F3  
R
3F  
2
R
P9F  
8F  
P9F  
8F  
8F  
8F  
P9F  
C
3
R
5
R
6
U4F1  
RP1F  
2
RP2F  
2
3
R
3F  
3
R
5F2  
R
1
R
4
Q1F  
1
Q1F  
2
R
R
3F  
4
J4F4J4F5  
C
C
R
4F  
4F  
4F  
3
5
7
3F  
5
C
4F  
4
R
5
R5F3  
U3F1  
J4F6  
C4F7  
C
5F  
4
R
P1F  
3
R
R
P2F  
C
4F  
6
R
P9F  
6
7
C
5F  
5
R
5F  
4
R
2
C8F2  
J4F7  
R
5F  
6
R
5F  
5
C
3
C
C
3F  
3F  
2
3
RP9F  
RP1F  
4
P2F  
4
5
R
3
CR1F1  
C
4F  
8
R
8
C5F6  
R
P9F  
9
R4F  
8
RP1F  
5
RP2F  
R
8F  
4
R4F  
9
C1F2  
R
P9F10  
R
R
R
4F10  
4F11  
4F13  
R
P9F11  
TP4F1  
R
P1F  
6
R
P2F  
6
C
C
3F  
3F  
4
5
C9F14  
C
1F  
3
R4F14  
RP9F12  
C8G1  
MH9G1  
MH5G1  
J3G1  
C1G1  
R
R6G  
6G  
2
1
C
C3G  
3G  
2
1
Q6G1  
C
9G  
1
154.94  
[ 6.100  
]
R
P9G1  
C5G1  
C
1G  
2
R
1G  
1
C4G1  
U1G1  
R
9G  
1
C3G3  
U
2G  
1
C5G2  
R2G1  
R
9G  
2
Q6G2 Q6G3  
6G 6G  
R
2G  
2
C8G3  
R
9G  
3
C
9G  
9G  
9G  
2
R
2G  
3
4
RP9G2  
J3G3  
R
4G  
1
R4G2  
R
9G  
4
Q2G1  
R
3
R
4
R2G  
R
R
5
7
R
9G  
6
C
1G  
3
R
9G  
8
R
P9G  
3
R
1G  
2
Y
4G1  
U2G3  
R
9G  
9
R
1G  
3
C2G2  
J6G1  
J7G1  
R
9G10  
U3G  
1
U3G2  
C4G6  
R
R
P9G  
4
R7G4  
HS6J1  
RP9G5  
C
2G7  
R
2G  
2G  
2G  
7
R
P1G  
1
C3G10  
R
8
P9G  
6
R2G9  
R2G10  
R2G11  
C
8
R
P9G  
7
RP1G  
2
R3G23  
C5G6  
RP9G8  
J3G4  
J2G1  
R
P9G  
9
Y2G1  
U2H2  
R
9G11  
R
P9G10  
177.80  
[ 7.000  
]
RP9H  
1
R
2H3  
C
2H  
1
R
6H  
6H  
6H  
1
R
2H  
4
C6H2  
R
P9H2  
R
R
3
4
C
2H2  
R
R
P9H  
3
U2H1  
C
4H2  
R
P9H4  
C
2H9  
P9H  
5
C5H2  
R
8H  
1
2
R
4H  
4
4
5
7
8
R
P9H6  
C
R
4H  
4H  
R8H  
U6H1  
R
P9H7  
RP9H  
8
R
4H  
XBT3H1  
R
4H  
C9H14  
P9H  
L5H1  
C2H14  
C
2H15  
R
8H3  
9H  
1
C2H16  
C2H17  
U1H1  
R
9
C
1H  
2
C
C2H18  
R2H12  
C5H6  
U2H3  
R5H2  
R
P9H10  
R
P9H11  
U2J1  
C2H19  
C2J1  
R
P9H12  
R5H3  
Q5H2  
Q5J1  
Q5J2  
Q5H1  
R
P9H13  
R
P9H14  
9J2  
P9J2  
9J7  
C2H20  
C
R6J3  
C6J1  
R
R
2J2  
2J3  
R
6J2  
D2J1  
C
9J3  
9J6  
9J8  
R
6J6  
C2J2  
C
2J3  
RP9J1  
R
C1J2  
U1J1  
R2J6  
C
C
6J4  
Q3J2  
Q6J2  
Q3J1  
C
R2J8  
R6J12  
Q2J2  
C3J1  
RP9J3  
C
C2J4  
C5J5  
C
R
C
7J1  
7J4  
7J3  
R
P9J4  
R
6J13  
6J8  
6J9  
J7J1  
C
J6J1  
C9J11  
R
7J5  
7J6  
7J7  
R
C
R
7J6  
7J7  
7J8  
RP9J5  
J3J1  
C9J12  
C
C
R
R
P9J6  
C4J2  
C9J13  
C7J9  
C8J5  
C6J17  
C8J4  
C8J3  
Q1J1 Q1J2  
Q1J3 Q1J4  
RP7J1  
C
R
7J1  
C9J16  
MH1J1  
MH9J1  
C3J4  
L5J1  
EU6J1  
C6J19  
R
7J11  
MH5J1  
J7J2  
J7J3  
J6J2  
J1J2  
227.33  
233.68  
[ 8.950  
[ 9.200  
]
]
RT7J1  
J1J3  
Q7J1  
C6J23  
R6J26  
C6J22  
R5J6  
R7J12  
J3J2  
SM1SIDE1  
A0039501 E01  
Figure 2. Intel Server Board SE7210TP1-E Mechanical Drawing  
6
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3. Functional Architecture  
This chapter provides a high-level description of the functionality distributed between the  
architectural blocks of the Intel Server Board SE7210TP1-E.  
3.1 Processor Subsystem  
The support circuitry for the processor sub-system consists of the following:  
Single µPGA478 processor socket  
Processor host bus AGTL+ support circuitry.  
Reset configuration logic.  
7
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.1.1  
Reset Configuration Logic  
The BIOS determines the processor stepping, cache size, and other processor information  
through the CPUID instruction. The requirement is for the processor to run at a fixed speed. The  
processor cannot be programmed to operate at a lower or higher speed.  
On the SE7210TP1-E platform, the BIOS is responsible for configuring the processor speed.  
The BIOS uses CMOS settings to determine which speed to program into the speed setting  
device. The processor information is read at every system power-on.  
3.1.2  
Processor Support  
The Intel Server Board SE7210TP1-E supports a single Intel® Pentium® 4 processor, or a single  
Intel® Celeron® processor with a system bus of 400 /533 /800 MHz. The server board supports  
the processors listed in Table 1.  
Table 1. Processor Support Matrix  
Type  
Pentium® 4 processor supporting Hyper-Threading  
Technology  
Designation  
3.4, 3.2 GHz  
System Bus  
L2 Cache Size  
800 MHz  
2 MB  
Pentium® 4 processor supporting Hyper-Threading  
3.4, 3.2, 3.0, 2.8  
GHz  
2.8 GHz  
800 MHz  
533 MHz  
1 MB  
Technology  
Pentium® 4 processor supporting Hyper-Threading  
Technology  
1 MB  
Pentium® 4 processor supporting Hyper-Threading  
3.2, 3.0, 2.80, 2.40, 800 MHz  
2.60 GHz  
512 KB  
512 KB  
512 KB  
128 KB  
Technology  
Pentium® 4 processor supporting Hyper-Threading  
Technology  
Pentium® 4 processor  
3.06 GHz  
533 MHz  
2.8, 2.66, 2.6, 2.53, 400 / 533 MHz  
2.4, 2.26, 2.0 GHz  
Celeron® processor  
2.8, 2.7, 2.6, 2.5,  
2.4, 2.3, 2.2, 2.1,  
2.0 GHz  
400 MHz  
CAUTION  
Use only the processors listed above. Use of unsupported processors can damage the board,  
the processor, and the power supply. See the Intel® Server Board SE7210TP1-E Specification  
Update or go to http://support.intel.com/support/motherboards/server/SE7210TP1-E/ for the  
current list of supported processors for this board.  
NOTE  
Use only ATX12V or EPS12V compliant power supplies with the server board SE7210TP1-E.  
ATX12V and EPS12V power supplies have an additional power lead that provides required  
supplemental power for the Intel Pentium 4 processor. The board will not boot if you do not  
connect the 20-pin (or 24-pin) and 4-pin (or 8-pin) leads of ATX12V or EPS12V power supplies  
to the corresponding connectors.  
Do not use a standard ATX power supply. The board will not boot with a standard ATX power  
supply.  
8
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.1.3  
Microcode  
IA32 processors have the capability of correcting specific errata through the loading of an Intel-  
supplied data block (microcode update). The BIOS is responsible for storing the update in  
nonvolatile memory and loading it into each processor during POST. The BIOS performs all the  
recommended update signature verification prior to storing the update in the Flash.  
3.1.4  
Processor Cache  
The BIOS enables all levels of processor cache as early as possible during POST. There are no  
user options to modify the cache configuration, size or policies. All detected cache sizes are  
reported in the SMBIOS Type 7 structures. The largest and highest level cache detected is  
reported in BIOS Setup  
3.1.5  
Hyper-Threading Technology  
Intel® Pentium® 4 processors support Hyper-Threading Technology. The BIOS will detect  
processors that support this feature and will enable the feature during POST. BIOS Setup  
provides an option to selectively enable or disable this feature. The default behavior is enabled.  
The BIOS will create additional entries in the ACPI MP tables to describe the virtual processors.  
The SMBIOS Type 4 structure will show only the physical processors installed.  
3.2 Intel E7210 Chipset  
The Intel E7210 chipset consists of the following devices:  
Intel 827210 Memory Controller Hub (MCH) with Accelerated Hub Architecture (AHA)  
bus  
Intel 6300ESB I/O Controller Hub with AHA bus  
Intel 82802AC (8 Mbit) Firmware Hub (FWH)  
3.2.1  
Intel 827210 Memory Controller Hub (MCH)  
The MCH is a centralized controller for the system bus, the memory bus and the Accelerated  
Hub Architecture interface. The 6300ESB I/O is a centralized controller for the Server Board  
SE7210TP1-E’s I/O paths. The FWH provides the nonvolatile storage of the BIOS. The  
component combination provides the chipset interfaces as shown in Figure 3.  
9
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Figure 3. Intel E7210 Chipset Block Diagram  
3.2.2  
Intel 82802AC 8 Megabit Firmware Hub (FWH)  
The FWH provides the following:  
System BIOS program  
Logic that enables protection for storing and updating platform information  
3.2.3  
PCI-X  
The PCI-X segment comes from 6300ESB I/O, and only runs at 66MHz maximum.  
The PCI-X interfaces of the 6300ESB I/O are compliant with the PCI-X Addendum to the PCI  
Local Bus Specification Revision 1.0b as well as the Mode 1 and Mode 2 (266 MHz) sections of  
the PCI-X Electrical and Mechanical Addendum to the PCI Local Bus Specification Revision  
2.0a and the PCI-X Protocol Addendum to the PCI Local Bus Specification Revision 2.0a. PCI-X  
Mode 2 provides enhancements over PCI that enable faster and more efficient data transfers.  
For conventional PCI Mode, the 6300ESB I/O supports PCI bus frequencies of 66 MHz,  
100 MHz, and 133 MHz. For the PCI-X Mode 2, the 6300ESB I/O supports PCI bus frequencies  
of 66 MHz, 100 MHz, 133 MHz and 266 MHz.  
On the SE7210TP1-E server board, the PCI-X interface (P64-A) is independently controlled to  
operate in either a conventional PCI or PCI-X mode. P64-A is routed to control I/O from the  
82547GI Ethernet controller and is capable of supporting MCH CSA interfaces depending on  
the riser card used. P32-A is routed to control I/O from the 32-bit PCI slot and the Adaptec*  
7901Single Channel SCSI controller.  
3.2.4  
Low Profile Riser Slot  
The Low Profile riser slot is a standard 202-pin slot supporting PCI-X signals. Its location on the  
board will allow only the use of low profile add-in cards.  
10  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.2.5  
SMBus Interface  
The SMBus interface can be used for system and power management related tasks. The  
interface is compliant with System Management Bus Specification Revision 2.0. The SMBus  
interface allows full read/write access to all configuration and memory spaces in the FWH.  
3.2.6  
6300ESB I/O Controller Hub  
The 6300ESB I/O is a multi-function device providing an upstream hub interface for access to  
several embedded I/O functions and features including:  
PCI Local Bus Specification, Revision 2.2 with support for 33 MHz PCI operations  
and 66 MHz PCI-X operations.  
ACPI power management logic support  
Enhanced DMA controller, interrupt controller, and timer functions  
Integrated IDE controller with support for Ultra ATA100/66/33  
Integrated SATA controller  
USB host interface with support for four USB ports; two UHCI host controllers; one  
EHCI high-speed USB 2.0 host controller  
System Management Bus (SMBus) Specification, Version 2.0 with additional support  
for I2C devices  
Low Pin Count (LPC) interface  
Firmware Hub (FWH) interface support  
Each function within the 6300ESB has its own set of configuration registers. Once configured,  
each appears to the system as a distinct hardware controller sharing the same PCI bus  
interface.  
Performance Note: The Hub Link 1.5 interface between the 6300ESB ICH and the 827210  
MCH has a theoretical maximum throughput of 266MB/s. Each bus supported by the 6300ESB  
ICH will share the Hub Link 1.5 bandwidth, this includes the P64-A bus, the P32-A bus, the  
BMC interface, the LPC bus, the USB 2.0 interface, the Parallel ATA bus and the Serial ATA  
bus.  
3.2.7  
PCI Interface  
The 6300ESB I/O PCI interface provides a 33 MHz, Revision 2.3 compliant implementation. All  
PCI signals are 5-V tolerant, except PME#. The 6300ESB I/O integrates a PCI arbiter that  
supports up to four external PCI bus masters in addition to the internal 6300ESB I/O requests.  
On the SE7210TP1-E server board this PCI interface is used to support on-board PCI devices  
including the ATI* video controller.  
11  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.2.8  
IDE Interface  
The 6300ESB I/O IDE controller has two independent bus-mastering IDE interfaces that can be  
independently enabled. The IDE interfaces support the following modes:  
Programmed I/O (PIO): processor controls data transfer.  
8237-style DMA: DMA offloads the processor, supporting transfer rates of up to  
16 MB/sec.  
Ultra DMA: DMA protocol on IDE bus supports Ultra 100 DMA Mode Transfers up to  
100Mbytes/s for reads from disk;88.88 Mbytes/s for writes to disk. As well as Ultra66  
and Ultra33 DMA mode..  
ATA-66: DMA protocol on IDE bus supporting host and target throttling and transfer  
rates of up to 66 MB/sec. The ATA-66 protocol is similar to Ultra DMA and is device  
driver compatible.  
ATA-100: DMA protocol on IDE bus allows host and target throttling. The 6300ESB I/O  
ATA-100 logic can achieve read transfer rates up to 100 MB/sec and write transfer rates  
up to 88 MB/sec.  
NOTE  
ATA-66 and ATA-100 are faster timings and require a specialized 40-pin, 80-wire cable to  
reduce reflections, noise, and inductive coupling.  
The IDE interfaces also support ATAPI devices (such as CD-ROM drives) and ATA devices  
using the transfer modes. The BIOS supports Logical Block Addressing (LBA) and Extended  
Cylinder Head Sector (ECHS) translation modes. The drive reports the transfer rate and  
translation mode to the BIOS.  
The server board SE7210TP1-E supports Laser Servo (LS-120) diskette technology through the  
IDE interfaces. The BIOS supports booting from an LS-120 drive.  
NOTE  
The BIOS will always recognize an LS-120 drive as an ATAPI floppy drive. To ensure correct  
operation, do not configure the drive as a hard disk drive.  
3.2.9  
Serial ATA (SATA) Controller  
The SATA controller supports two SATA devices providing an interface for SATA hard disks and  
ATAPI devices. The SATA interface supports PIO IDE transfers up to 16 Mb/s and Serial ATA  
transfers up to 1.5 Gb/s (150 MB/s). The 6300ESB I/O’s SATA system contains two  
independent SATA signal ports. They can be electrically isolated independently. Each SATA  
device can have independent timings. They can be configured to the standard primary and  
secondary channels.  
12  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.2.10  
Low Pin Count (LPC) Interface  
The 6300ESB I/O implements an LPC Interface as described in the Low Pin Count Interface  
Specification, Revision 1.1. The Low Pin Count (LPC) Bridge function of the 6300ESB I/O  
resides in PCI Device 31: Function 0. In addition to the LPC bridge interface function, D31:F0  
contains other functional units including DMA, interrupt controllers, timers, power management,  
system management, GPIO, and RTC.  
3.2.11  
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt  
Controller)  
The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven  
independently programmable channels. Channels 0–3 are hardwired to 8-bit, count-by-byte  
transfers, and channels 5–7 are hardwired to 16-bit, count-by-word transfers. Any two of the  
seven DMA channels can be programmed to support fast Type-F transfers.  
The 6300ESB I/O supports two types of DMA (LPC and PC/PCI). LPC DMA and PC/PCI DMA  
use the 6300ESB I/O’s DMA controller. The PC/PCI protocol allows PCI-based peripherals to  
initiate DMA cycles by encoding requests and grants via two PC/PC REQ#/GNT# pairs. LPC  
DMA is handled through the use of the LDRQ# lines from peripherals and special encoding on  
LAD[3:0] from the host. Single, Demand, Verify, and Increment modes are supported on the  
LPC interface. Channels 0–3 are 8 bit channels. Channels 5–7 are 16 bit channels. Channel 4  
is reserved as a generic bus master request.  
The timer/counter block contains three counters that are equivalent in function to those found in  
one 82C54 programmable interval timer. These three counters are combined to provide the  
system timer function, and speaker tone. The 14.31818 MHz oscillator input provides the clock  
source for these three counters.  
The 6300ESB I/O provides an ISA-compatible Programmable Interrupt Controller (PIC) that  
incorporates the functionality of two 82C59 interrupt controllers. The two interrupt controllers are  
cascaded so that 14 external and two internal interrupts are possible. In addition, the 6300ESB  
I/O supports a serial interrupt scheme. All of the registers in these modules can be read and  
restored. This is required to save and restore system state after power has been removed and  
restored to the platform.  
3.2.12  
Advanced Programmable Interrupt Controller (APIC)  
In addition to the standard ISA-compatible PIC described in the previous section, the 6300ESB  
I/O incorporates the Advanced Programmable Interrupt Controller (APIC).  
3.2.13  
Universal Serial Bus (USB) Controller  
The 6300ESB I/O contains an Enhanced Host Controller Interface Specification for Universal  
Serial Bus, Revision 1.0 -compliant host controller that supports USB high-speed signaling.  
High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-  
speed USB. The 6300ESB I/O also contains four Universal Host Controller Interface (UHCI)  
controllers that support USB full-speed and low-speed signaling.  
13  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
The Intel Server Board SE7210TP1-E supports up to four USB 2.0 ports, supports Universal  
Host Controller Interface (UHCI) and Enhanced Host Controller Interface (EHCI), and uses  
UHCI- and EHCI-compatible drivers.  
The 6300ESB I/O provides the USB controller for all ports, as shown in Figure 4. The port  
arrangement is as follows:  
Three ports are implemented with stacked back panel connectors  
One port is routed to a USB header which can be connected with a USB cable to the  
front panel connector  
Figure 4. USB Port Configuration  
NOTES  
Server systems that have an unshielded cable attached to a USB port may not meet FCC  
Class B requirements, even if no device is attached to the cable. Use shielded cable that  
meets the requirements for full-speed devices.  
3.2.14  
Real Time Clock, CMOS SRAM, and Battery  
The real-time clock provides a time-of-day clock and a multi-century calendar with alarm  
features. The real-time clock supports 256 bytes of battery-backed CMOS SRAM in two banks  
that are reserved for BIOS use.  
A coin-cell battery (CR2032) powers the real-time clock and CMOS memory. When the server is  
not plugged into a wall socket, the battery has an estimated life of three years. When the server  
is plugged in, the standby current from the power supply extends the life of the battery. The  
clock is accurate to ± 13 minutes/year at 25 ºC with 3.3 VSB applied.  
The time, date, and CMOS values can be specified in the BIOS Setup program. The CMOS  
values can be returned to their defaults by using the BIOS Setup program.  
NOTE  
If the battery and AC power fail, the custom defaults, if previously saved, will be loaded into  
CMOS RAM at power-on.  
14  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.2.15  
GPIO  
Various general purpose inputs and outputs are provided for custom system design. The  
number of inputs and outputs varies depending on the 6300ESB I/O configuration. All unused  
GPI pins must be pulled high or low, so that they are at a predefined level and do not cause  
undue side effects.  
3.2.16  
Enhanced Power Management  
The 6300ESB I/O’s power management functions include enhanced clock control, local and  
global monitoring support for 14 individual devices, and various low-power (suspend) states  
(e.g., Suspend-to-DRAM and Suspend-to-Disk). A hardware-based thermal management circuit  
permits software-independent entrance to low-power states. The 6300ESB I/O contains full  
support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision  
2.0b.  
3.2.17  
System Management Bus (SMBus 2.0)  
The 6300ESB I/O contains an SMBus Host interface that allows the processor to communicate  
with SMBus slaves. This interface is compatible with most I2C devices. Special I2C commands  
are implemented. The 6300ESB I/O’s SMBus host controller provides a mechanism for the  
processor to initiate communications with SMBus peripherals (slaves). Also, the 6300ESB I/O  
supports slave functionality, including the Host Notify protocol. Hence, the host controller  
supports eight command protocols of the SMBus interface (see System Management Bus  
(SMBus) Specification, Version 2.0): Quick Command, Send Byte, Receive Byte, Write  
Byte/Word, Read Byte/Word, Process Call, Block Read/Write, and Host Notify.  
3.3 Memory Subsystem  
The Intel 827210 Memory Controller Hub (MCH) is one component of the Intel E7210 chipset.  
The MCH is a centralized controller for the system bus, the memory bus and the accelerated  
hub architecture interface.  
The server board SE7210TP1-E provides four DIMM slots and supports a maximum memory  
capacity of 4 GB. The DIMM organization is x72, which includes eight ECC check bits. ECC from  
the DIMMs are passed through to the processor’s system bus. Memory scrubbing, single-bit  
error correction and multiple-bit error detection is supported. Memory can be implemented with  
either single-sided (one row) or double-sided (two row) DIMMs.  
15  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Table 2. Supported Memory Configurations  
DIMM Capacity Configuration  
DDR SDRAM  
Density  
DDR SDRAM Organization  
Front-side/Back-side  
8 M x 8/8 M x 8  
Number of DDR  
SDRAM Devices  
16  
8
4
16  
8
4
16  
8
16  
128 MB  
128 MB  
128 MB  
256 MB  
256 MB  
256 MB  
512 MB  
512 MB  
1024 MB  
DS  
SS  
SS  
DS  
SS  
SS  
DS  
SS  
DS  
64 Mbit  
128 Mbit  
256 Mbit  
128 Mbit  
256 Mbit  
512 Mbit  
256 Mbit  
512 Mbit  
512 Mbit  
16 M x 8/empty  
16 M x 16/empty  
16 M x 8/16 M x 8  
32 M x 8/empty  
32 M x 16/empty  
32 M x 8/32 M x 8  
64 M x 8/empty  
64 M x 8/64 M x 8  
Note: In the second column, “DS” refers to double-sided memory modules (containing two rows of DDR  
SDRAM) and “SS” refers to single-sided memory modules (containing one row of DDR SDRAM).  
DIMM and memory configurations must adhere to the following:  
2.5 V (only) 184-pin DDR SDRAM DIMMs with gold-plated contacts  
Unbuffered, single-sided or double-sided DIMMs with the following restriction:  
Double-sided DIMMS with x16 organization are not supported.  
Maximum total system memory: 4 GB  
Minimum total system memory: 128 MB  
ECC and non-ECC DIMMs supported  
Serial Presence Detect  
PC3200 (400 MHZ), PC2700 (333 MHZ), and PC2100 (266 MHZ) SDRAM DIMMs  
Table 3 lists the supported system bus frequency and memory speed combinations.  
Table 3. Supported System Bus Frequency and Memory Speed Combinations  
To use this type of DIMM…  
The processor's system bus frequency must be…  
PC3200 (400 MHZ)  
800 MHz  
PC2700 (333 MHZ)  
PC2100 (266 MHZ)  
800 or 533 MHz (Note)  
800, 533, or 400 MHz  
Note: When using PC2700 (333 MHZ) memory with an 800 MHz system bus frequency processor, the memory  
channel will be set to 320 MHz.  
Only DIMMs tested and qualified by Intel or a designated memory test vendor will be supported  
on the Intel Server Board SE7210TP1-E. A list of qualified DIMMs will be made available  
through http://support.intel.com/support/motherboards/server/SE7210TP1-E/. Note that all  
DIMMs are supported by design, but only fully qualified DIMMs will be supported.  
16  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
NOTES  
To be fully compliant with all applicable DDR SDRAM memory specifications, the board  
should be populated with DIMMs that support the Serial Presence Detect (SPD) data  
structure. This allows the BIOS to read the SPD data and program the chipset to accurately  
configure memory settings for optimum performance. If non-SPD memory is installed, the  
BIOS will attempt to correctly configure the memory settings, but performance and reliability  
may be impacted or the DIMMs may not function under the determined frequency.  
For ECC functionality, all installed DIMMs must be ECC. If both ECC and non-ECC DIMMs  
are used, ECC will be disabled and will not function.  
3.3.1  
Memory Configurations  
The Intel 827210 MCH component provides two features for enhancing memory throughput:  
Dual Channel memory interface. The board has two memory channels, each with two  
DIMM sockets.  
Dynamic Addressing Mode. Dynamic mode minimizes overhead by reducing memory  
accesses.  
Table 4 summarizes the characteristics of dual and single channel configurations with and  
without the use of Dynamic Mode.  
Table 4. Characteristics of Dual/Single Channel Configuration with/without Dynamic Mode  
Throughput  
Level  
Configuration  
Characteristics  
Highest  
Dual Channel with Dynamic Mode  
All DIMMs matched  
(Example configurations are shown in Figure 5)  
DIMMs matched from Channel A to Channel B  
DIMMs not matched within channels  
Dual Channel without Dynamic Mode  
(Example configuration is shown in Figure 6)  
Single DIMM or DIMMs matched with a channel  
(Example configurations are shown in Figure 7)  
Single Channel with Dynamic Mode  
Single Channel without Dynamic Mode  
Lowest  
DIMMs not matched  
(Example configurations are shown in Figure 8)  
17  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Dual Channel Configuration with Dynamic Mode  
(All DIMMs Matched)  
Figure 5. Examples of Dual Channel Configuration with Dynamic Mode  
18  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Dual Channel Configuration without Dynamic Mode  
- DIMMs not matched within channel  
- DIMMs match Channel A to Channel B  
Figure 6. Example of Dual Channel Configuration without Dynamic Mode  
19  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Single Channel Configuration with Dynamic Mode  
(Single DIMM or DIMMs matched within Channel)  
Figure 7. Examples of Single Channel Configuration with Dynamic Mode  
20  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Single Channel Configuration without Dynamic Mode  
(DIMMs not matched)  
Figure 8. Examples of Single Channel Configuration without Dynamic Mode  
21  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4 I/O Sub-System  
The I/O sub-system is made up of several components: the 6300ESB I/O providing the PCI-X  
interfaces for the three PCI slots and riser slot on board 3, the on-board SCSI controller, the on-  
board Ethernet controllers, the onboard video controller, Super IO chip, and Management Sub-  
system. This section describes the function of each I/O interface and how they operate on the  
SE7210TP1-E server board.  
3.4.1  
PCI Sub-System  
The primary I/O bus for the Intel Server Board SE7210TP1-E is PCI, with two independent PCI  
buses. The PCI buses comply with the PCI Local Bus Specification, Rev 2.2. The PCI bus is  
directed through the Intel 6300ESB I/O Controller Hub. The table below lists the characteristics  
of the two PCI bus segments.  
Table 5: PCI Bus Segment Characteristics  
PCI Bus Segment  
Voltage  
Width  
Speed  
Type  
PCI  
PCI I/O Card Slots  
1 - capable of supporting full-  
length PCI add-in cards.  
Internal component use.  
P32-A  
5 V  
32-bits  
33 MHz  
3 - capable of supporting full-  
length PCI-X add-in cards  
1 - riser slot supporting low-  
profile add-in cards (Only on  
board 3)  
P64-A  
P64-A  
3.3 V  
3.3 V  
64-bits  
64-bits  
66 MHz  
66 MHz  
PCI-X  
PCI-X  
3.4.1.1  
P32-A: 32-bit, 33MHz PCI Sub-system  
All 32-bit, 33-MHz PCI I/O for the SE7210TP1-E server board is directed through the 6300ESB  
I/O. The 32-bit, 33-MHz PCI segment created by the 6300ESB I/O is known as the P32-A  
segment. The P32-A segment supports the following devices:  
One 32-bit PCI slot  
2D/3D Graphics Accelerator: ATI Rage XL Video Controller  
SIO Chip: Winbond* W83627 HF-AW Super I/O  
Hardware monitoring sub-system: SMBUS.  
3.4.1.2  
P64-A: 64-bit, 66MHz PCI Subsystem  
There is one 64-bit PCI-X bus segment directed through the 6300ESB I/O. P64-A supports the  
interface for the on-board Adaptec* 7901 Ultra 320 SCSI controller in addition to supporting up  
a maximum of three PCI slots.  
3.4.1.3  
Scan Order  
The BIOS assigns PCI bus numbers in a depth-first hierarchy, in accordance with the PCI Local  
Bus Specification. When a bridge device is located, the bus number is incremented in exception  
22  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
of a bridge device in the chipsets. Scanning continues on the secondary side of the bridge until  
all subordinate buses are defined. PCI bus numbers may change when PCI-PCI bridges are  
added or removed. If a bridge is inserted in a PCI bus, all subsequent PCI bus numbers below  
the current bus will be increased by one.  
3.4.1.4  
Resource Assignment  
The resource manager assigns the PIC-mode interrupt for the devices that will be accessed by  
the legacy code. The BIOS will ensure the PCI BAR registers and the command register for all  
devices are correctly set up to match the behavior of the legacy BIOS. Code cannot make  
assumptions about the scan order of devices or the order in which resources will be allocated to  
them. The BIOS will support the INT 1Ah PCI BIOS interface calls.  
3.4.1.5  
Automatic IRQ Assignment  
The BIOS automatically assigns IRQs to devices in the system for legacy compatibility. No  
method is provided to manually configure the IRQs for devices.  
3.4.1.6  
Option ROM Support  
The option ROM support code in the BIOS will dispatch the option ROMs in available memory  
space in the address range 0C0000h-0DFFFFh and will follow all rules with respect to the  
option ROM space. The SE7210TP1-E BIOS will integrate option ROMs for the Intel 82547GI,  
Intel 82551QM, ATI Rage XL, SATA RAID and Adaptec 7901 SCSI controller.  
3.4.1.7  
Zero Channel RAID (ZCR) Capable Slot  
The SCSI version of the Server Board SE7210TP1-E is capable of supporting the following zero  
channel RAID controllers, the Intel® RAID Controller SRCZCR and the Adaptec* ASR-2010S  
RAID adapter. ZCR cards are only supported in slot one the P64-A PCI segment.  
The ZCR add-in cards leverage the on-board SCSI controller along with their own built-in  
intelligence to provide a complete RAID controller subsystem on-board. The riser card and  
baseboard use an implementation commonly referred to as RAID I/O Steering (RAIDIOS)  
specification version 0.92 to support this feature. If either of these supported RAID cards are  
installed, then the SCSI interrupts are routed to the RAID adapter instead of to the PCI interrupt  
controller. Also the IDSEL of the SCSI controller is not driven to the controller and thus will not  
respond as an on-board device. The host-based I/O device is effectively hidden from the system.  
23  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.2  
DMA Channels  
Table 6. DMA Channels  
DMA Channel  
Data Width  
System Resource  
Number  
0
8 or 16 bits Open  
8 or 16 bits  
8 or 16 bits Diskette drive  
8 or 16 bits  
1
2
3
4
5
6
7
8 or 16 bits DMA controller  
16 bits  
16 bits  
16 bits  
Open  
Open  
Open  
3.4.3  
Interrupts  
The interrupts can be routed through the Advanced Programmable Interrupt Controller (APIC)  
portion of the 6300ESB I/O component. The APIC is supported in Windows* 2000 Server and  
Windows XP and supports a total of 24 interrupts.  
Table 7. Interrupts  
IRQ  
System Resource  
NMI  
0
1
I/O channel check  
Reserved, interval timer  
Reserved, keyboard buffer full  
2
3
4
Reserved, cascade interrupt from slave PIC  
COM2 (Note 1)  
COM1 (Note 1)  
6
Diskette drive  
8
Real-time clock  
9
Reserved for 6300ESB I/O system management bus  
User available  
User available  
Onboard mouse port (if present, else user available)  
Reserved, math coprocessor  
Primary IDE (if present, else user available)  
Secondary IDE (if present, else user available)  
USB UHCI controller 1 (through PIRQA)  
User available (through PIRQB)  
6300ESB I/O USB controller 3 (through PIRQC)  
6300ESB I/O USB controller 2 (through PIRQD)  
6300ESB I/O LAN (through PIRQE)  
User available (through PIRQF)  
User available (through PIRQG)  
6300ESB I/O USB 2.0 EHCI controller/User available (through PIRQH)  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
Notes:  
1. Default, but can be changed to another IRQ.  
24  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.4  
PCI Interrupt Routing Map  
This section describes interrupt sharing and how the interrupt signals are connected between  
the PCI bus connectors and onboard PCI devices. The PCI specification specifies how  
interrupts can be shared between devices attached to the PCI bus. In most cases, the small  
amount of latency added by interrupt sharing does not affect the operation or throughput of the  
devices. In some special cases where maximum performance is needed from a device, a PCI  
device should not share an interrupt with other PCI devices. Use the following information to  
avoid sharing an interrupt with a PCI add-in card.  
PCI devices are categorized as follows to specify their interrupt grouping:  
INTA: By default, all add-in cards that require only one interrupt are in this category. For  
almost all cards that require more than one interrupt, the first interrupt on the card is also  
classified as INTA.  
INTB: Generally, the second interrupt on add-in cards that require two or more interrupts  
is classified as INTB. (This is not an absolute requirement.)  
INTC and INTD: Generally, a third interrupt on add-in cards is classified as INTC and a  
fourth interrupt is classified as INTD.  
The 6300ESB I/O has eight programmable interrupt request (PIRQ) input signals. All PCI  
interrupt sources either onboard or from a PCI add-in card connect to one of these  
PIRQ signals. Some PCI interrupt sources are electrically tied together on the Server Board  
SE7210TP1-E and therefore share the same interrupt. Table 8 shows an example of how the  
PIRQ signals are routed.  
For example, using Table 8 as a reference, assume an add-in card using INTB is plugged into  
PCI bus connector 3. In PCI bus connector 3, INTB is connected to PIRQA, which is already  
connected to the Promise PDC20319 Controller. The add-in card in PCI bus connector 3 now  
shares an interrupt with the onboard interrupt source.  
Table 8. PCI Interrupt Routing Map  
IDSEL  
P_AD18  
PX_AD19  
PX_AD20  
PX_AD17  
P_AD16  
INTF  
0
P_AD17  
INTB  
P_AD18  
INTA  
P_INTA*  
P_INTB*  
P_INTC*  
P_INTD*  
P_INTE*  
P_INTF*  
PX_INTA*  
PX_INTB*  
PX_INTC*  
PX_INTD*  
PX_IRQ*  
REQ/GNT  
INTB  
INTC  
INTD  
PIN B2, INTE  
PIN B4, INTE  
INTA  
INTB  
INTC  
INTD  
INTA  
INTC  
INTD  
INTA  
INTB  
INTB  
INTC  
SCSI_A*  
IRQ3  
0
SCSI  
1
2
3
1
2
PCI 64 bit  
PCI 64 bit  
PCI 64 bit  
ATI  
LAN  
PCI 32 bit  
SLOT1  
SLOT2  
SLOT3  
RAGE  
10/100  
SLOT6  
25  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
NOTE  
In PIC mode, the 6300ESB I/O can connect each PIRQ line internally to one of the IRQ signals  
(3, 4, 5, 6, 7, 9, 10, 11, 12, 14, and 15). Typically, a device that does not share a PIRQ line will  
have a unique interrupt. However, in certain interrupt-constrained situations, it is possible for  
two or more of the PIRQ lines to be connected to the same IRQ signal. See Table 7 for the  
allocation of PIRQ lines to IRQ signals in APIC mode.  
3.4.5  
SCSI Support  
The SCSI sub-system consists of the Adaptec 7901 Single Channel, PC-2001-compliant PCI-X  
Ultra 320 SCSI controller which has one internal 80-pin connector (SCSI Channel A).  
3.4.5.1  
Adaptec 7901 Single Channel Ultra 320 SCSI Controller  
The Adaptec 7901 is PCI bus master single-channel SCSI ASICs package. The Adaptec 7901  
is an Ultra320 SCSI ASIC supporting a data transfer rate up to 320 MB/sec. The Adaptec 7901  
complies with PCI Local Bus Specification, Revision 2.2 PCI-X Addendum, Rev. 1.0, and SCSI  
Parallel Interface-4 (SPI-4) for both Single-Ended (SE) and Low Voltage Differential (LVD)  
devices.  
These ASICs comply with:  
PCI Local Bus Specification, Revision 2.2  
PCI-X Addendum, Revision. 1.0a  
SCSI Parallel Interface-4 (SPI-4), Revision 6  
For both Single-Ended (SE) and LVD devices. In addition, they comply with the SCSI-3  
standard and provide multimode SCSI support.  
In PCI and PCI-X modes, these ASICs can operate as a multifunction 32-bit or 64-bit bus  
master capable of supporting zero-wait-state 32- or 64-bit memory transfers. They can also  
function as a PCI or PCI-X target.  
The Adaptec 7901 supports up to 64-bit, 122 MHz PCI-X bus. The Ultra320 SCSI features for  
the Adaptec 7901 include:  
z
z
z
z
z
z
z
z
z
Double-transition (DT) clocking  
Paced transfers using packetized protocol  
Packetized protocol  
Dual data FIFO  
Quick arbitration and selection/reselection (QAS) protocol  
Manual PIO mode data transfer  
Automatic mode data transfer  
Normal (DMA) mode data transfer  
Cyclic redundancy check (CRC) codes  
The single-channel Adaptec 7901 delivers Ultra320 SCSI data rates up to 320 MBytes/sec to  
address emerging bandwidth hungry applications, such as real-time video, data mining,  
Internet/Intranet, and scientific modeling and simulation. The chip features a 66 MHz, 64-bit PCI  
interface and a 133 MHz, 64-bit PCI-X interface.  
26  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Migration to new Ultra320 SCSI technology is easy with the Adaptec 7901. It is backward  
compatible with Ultra320, Ultra160, Ultra2, and earlier SCSI generations. The chip is available  
in a 356-pin Thermally Enhanced Ball Grid Array (TEBGA) package, which is signal compatible  
with the Ultra160 SCSI Adaptec 7892 for a smooth upgrade to Ultra320 SCSI.  
Now offered with the Adaptec 7901 is HostRAID*, an advanced RAID solution that includes  
hardware mirroring on the Adaptec 7901. HostRAID offers bootable RAID levels 0 and 1 with  
other advanced RAID features such as dedicated hot spares with automatic recovery, on-line  
capacity expansion, event scheduling, SAF-TE support, SNMP, DMI, and on-line RAID level  
migration.  
The Adaptec 7901 uses Ultra320 technology to double Ultra160 data transfer rates up to 320  
MBytes/sec. In addition, Adaptec Seamless Streaming* technology allows the Adaptec 7901 to  
take full advantage of the SCSI packet protocol enhancements (transfers multiple commands,  
data contexts and statuses in single connection) that replaces the legacy SCSI protocol  
(transfers single commands, data contexts or statuses per connection).  
The Adaptec 7901 also supports Quick Arbitration and Selection (QAS) and SCSI arbitration  
fairness. QAS reduces the overhead of control release on the SCSI bus from one device to  
another. This improvement reduces command overhead and maximizes bus utilization. SCSI  
arbitration fairness prevents a device from dominating the bus by guaranteeing that all devices  
have an opportunity to arbitrate.  
The Adaptec 7901 fully supports CRC for 16-bit SCSI synchronous data transfers. CRC detects  
data integrity errors that would not be detected by simple parity checking used by previous SCSI  
generations. The higher data rates achieved on existing Low Voltage Differential (LVD) cable  
configurations mandated this improved data integrity feature.  
The Adaptec 7901 fully supports Domain Validation, which provides two levels (Basic and  
Enhanced) of SCSI bus configuration testing to help ensure Ultra320 and Ultra160 SCSI  
topologies operate at optimum speed.  
Using Low Voltage Differential (LVD), each Adaptec 7901 channel supports a maximum of 15  
devices on a 12-meter cable. In a point-to-point arrangement, cabling can extend to 25 meters.  
The Adaptec 7901 incorporates an advanced multi-mode SCSI I/O cell that supports Ultra2,  
Ultra160, and Ultra320 SCSI LVD devices, as well as single-ended devices. With only Ultra2,  
Ultra160, and Ultra320 devices attached, the SCSI bus performs at full speed and full LVD  
cable lengths. When SE devices are attached, the bus defaults to SE speed and cable length.  
27  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.5.1.1  
Adaptec 7901 Summary of Features  
The Adaptec 7901 contains the following SCSI performance features:  
z
z
z
z
z
z
z
SCSI data transfers up to 320 MB/sec  
8- or 16-bit SCSI data path  
SCSI offsets to 254 transfers  
Advanced multimode I/O cell is compatible with LVD or SE devices  
Extensive hardware support for disconnect/reconnect and scatter/gather  
Full support for both initiator and target operations  
Full support for domain validation, which provides two levels (basic and enhanced) of  
SCSI bus configuration testing to help ensure Ultra320 and Ultra160 SCSI topologies  
operate at optimum speed  
z
z
Multiple target ID enables responses to multiple IDs as a SCSI target  
Full support for CRC for 16-bit SCSI synchronous data transfers. CRC detects data  
integrity errors that would not be detected by simple parity checking used by previous  
SCSI generations. The higher data rates achieved on existing LVD cable configurations  
mandated this improved data integrity feature.  
z
z
Supports Quick Arbitration and Selection (QAS) and SCSI arbitration fairness. QAS  
reduces overhead when bus control is transferred between devices. Arbitration fairness  
prevents devices from hogging the bus by guaranteeing each device a chance to  
arbitrate.  
Supports Seamless Streaming technology, which allows full implementation of SCSI  
packet protocol for sending many commands, receiving many statuses, and  
transferring data for many commands during one SCSI connection. There is virtually no  
delay between packets for different commands.  
The Adaptec 7901 has a 133 MHz, 64-bit PCI/PCI-X Host Interface that supports the following  
PCI features:  
z
z
PC2001 compliant  
Direct pin connection to the PCI/PCI-X interface, from 133-MHz, 64-bit interface down  
to PCI 33-MHz, 32-bit interface  
z
z
Leading and trailing offset bytes on a 32- or 64-bit bus  
Performance-enhanced 32-bit operating mode allows 32-bit data transactions with 32-  
and 64-bit addressing (SAC/DAC)  
z
3.3-V/5-V PCI and 3.3-V PCI-X interfaces provide flexibility for designing high  
performance, low-power systems  
z
z
z
z
z
z
PCI bus master and slave timing referenced to PCLK  
PCI bus-programmable Latency Timer, Cache Size, and Interrupt Line Select registers  
Supports external read access to the BIOS FLASH on the host bus adapter (HBA)  
Supports SEEPROM read and write word access with an Adaptec utility  
Medium PCI target device select response time  
Streaming PCI-enhanced master Direct Memory Access (DMA) read and write burst  
commands  
z
z
z
z
PCI bus address and data parity generation and checking  
Supports PCI PERR# and SERR# requirements  
Supports up to five outstanding split completions  
PCI bus address and data phase error generation for checking host and device error  
support  
28  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
z
PCI/PCI-X target latency of 16 clocks maximum for first target access cycle that  
transfers data and 8 clocks for other responses  
z
z
Supports wire interrupts and Message-Signaled Interrupts (MSI)  
Hardware-implemented endian support for command and scatter/gather data transfer  
to reduce driver translation overhead  
3.4.5.2  
Performance and Throughput  
The Adaptec 7901 contain improved Adaptec RISC-based processors (ARPs) that execute  
SCSI Control Blocks (SCBs) to initiate data transfers between the PCI-X and SCSI interfaces.  
The ARPs support execution speeds of 40 MIPS and provide 8 KB of SRAM microcode storage.  
These ASICs operate at up to 66 MHz in PCI mode with a maximum 533 MB/sec data burst rate.  
3.4.5.3  
PCI/PCI-X Mode Operation  
Depending on the state of the initialization pattern on the PCI bus during power up, the Adaptec  
7901 can be initialized to operate in either conventional PCI or PCI-X mode; both wire and  
message-signaled interrupts are supported.  
3.4.5.4  
PCI Bus  
The Adaptec 7901 performance levels at 3.3 VIO are as follows:  
z
z
z
z
When operation in PCI-X mode as a 64-bit bus master, the Adaptec 7901 can support  
memory data transfer up to 533 MB/sec at 66 MHz.  
When operation in PCI-X mode as a 32-bit bus master, the Adaptec 7901 can support  
memory data transfer up to 266 MB/sec at 66MHz  
When operation in PCI-X mode as a 64-bit bus master, the Adaptec 7901 can support  
memory data transfer up to 266 MB/sec at 33MHZ  
When operation in PCI-X mode as a 32-bit bus master, the Adaptec 7901 can support  
memory data transfer up to 133 MB/sec at 33MHZ  
3.4.5.5  
SCSI Bus  
The Adaptec 7901 can operate in SE or LVD mode, depending on the voltage level of the SCSI  
DIFFSENSE (F2), which is determined by the combination of the SCSI devices attached to the  
bus, the SCSI bus operates in SE mode and the SCSI data transfer rate is speed of the SCSI  
device currently transferring data.  
Note: The Adaptec 7901 does not support High Voltage Differential (HVD) devices. When an  
HVD device is detected, the bus goes tri-state and transmission stops.  
29  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.6  
IDE Support  
Integrated IDE controllers of the 6300ESB I/O provide two independent IDE channels, each  
capable of supporting up to two drives. A standard 40-pin IDE connector on the baseboard  
interfaces with both channels. Both IDE channels can be configured or enabled/disabled by  
accessing the BIOS Setup Utility during POST.  
3.4.6.1  
Ultra ATA/100  
The IDE interfaces of the ICH5R DMA protocol redefines signals on the IDE cable to allow both  
host and target throttling of data and transfer rates of up to 100 MB/s.  
3.4.6.2  
IDE Initialization  
The BIOS supports the ATA/ATAPI Specification, version 6 or later. The BIOS initializes the  
embedded IDE controller in the chipset (ICH5R) and the IDE devices that are connected to  
these devices. The BIOS scans the IDE devices and programs the controller and the devices  
with their optimum timings. The IDE disk read/write services that are provided by the BIOS will  
use PIO mode, but the BIOS will program the necessary Ultra DMA registers in the IDE  
controller so that the operating system can use the Ultra DMA Modes.  
3.4.7  
SATA Support  
The integrated Serial ATA (SATA) controller of the 6300ESB I/O provides two SATA ports on  
the baseboard. The SATA ports can be enabled/disabled and/or configured by accessing the  
BIOS Setup Utility during POST.  
The SATA function in the 6300ESB I/O has dual modes of operation to support different  
operating system conditions. In the case of Native IDE enabled operating systems, the  
6300ESB I/O has separate PCI functions for serial and parallel ATA. To support legacy  
operating systems, there is only one PCI function for both the serial and parallel ATA ports. The  
MAP register provides the ability to share PCI functions. When sharing is enabled, all decode of  
I/O is done through the SATA registers. Device 31, Function 1 (IDE controller) is hidden by  
software writing to the Function Disable Register (D31, F0, offset F2h, bit 1), and its  
configuration registers are not used. The SATA Capability Pointer Register (offset 34h) will  
change to indicate that MSI is not supported in combined mode.  
The 6300ESB I/O SATA controller features two sets of interface signals that can be  
independently enabled or disabled. Each interface is supported by an independent DMA  
controller. The 6300ESB I/O SATA controller interacts with an attached mass storage device  
through a register interface that is equivalent to that presented by a traditional IDE host adapter.  
The host software follows existing standards and conventions when accessing the register  
interface and follows standard command protocol conventions.  
SATA interface transfer rates are independent of UDMA mode settings. SATA interface transfer  
rates will operate at the bus’s maximum speed, regardless of the UDMA mode reported by the  
SATA device or the system BIOS.  
30  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.7.1  
SATA RAID  
The Adaptec HostRAID™ Technology solution, available with the 6300ESB I/O, offers data  
stripping for higher performance (RAID Level 0 and 1), alleviating disk bottlenecks by taking  
advantage of the dual independent SATA controllers integrated in the 6300ESB I/O. There is no  
loss of PCI resources (request/grant pair) or add-in card slot.  
Adaptec HostRAID Technology functionality requires the following items:  
6300ESB I/O  
Two SATA hard disk drives.  
Adaptec Host RAID Technology is not available in the following configurations:  
The SATA controller in compatible mode.  
Adaptec Host RAID Technology has been disabled - D31:F0:AE bits [7:6] have been  
cleared  
3.4.7.2  
Adaptec Host RAID Technology Option ROM  
HostRAID offers bootable RAID levels 0 and 1 with other advanced RAID features such as  
dedicated hot spares with automatic recovery, on-line capacity expansion, event scheduling,  
SAF-TE support, SNMP, DMI, and on-line RAID level migration.  
3.4.8  
Video Controller  
The SE7210TP1-E server board provides an ATI* Rage XL PCI graphics accelerator, along with  
8 MB of video SDRAM and support circuitry for an embedded SVGA video subsystem. The ATI  
Rage XL chip contains a SVGA video controller, clock generator, 2D and 3D engine, and  
RAMDAC in a 272-pin PBGA. One 2Mx32 SDRAM chip provides 8 MB of video memory.  
The SVGA subsystem supports a variety of modes, up to 1600 x 1200 resolution in 8/16/24/32  
bpp modes under 2D, and up to 1024 x 768 resolution in 8/16/24/32 bpp modes under 3D. It  
also supports both CRT and LCD monitors up to 100 Hz vertical refresh rate.  
Video is accessed using a standard 15-pin VGA connector found on the back edge of the server  
board. On-board video can be disabled using the BIOS Setup Utility which is accessed during  
POST or when an add-in video card is installed in any of the PCI slots.  
31  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
3.4.8.1  
Video Modes  
The Rage XL chip supports all standard IBM VGA modes. The following table shows the 2D/3D  
modes supported for both CRT and LCD.  
Table 9: Video Modes  
2D Mode  
640x480  
Refresh Rate (Hz)  
SE7210TP1-E 2D Video Mode Support  
8 bpp  
16 bpp  
24 bpp  
32 bpp  
60, 72, 75, 90, 100  
60, 70, 75, 90, 100  
60, 72, 75, 90, 100  
43, 60  
70, 72  
60, 66  
Supported  
Supported  
Supported  
Supported  
800x600  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
1024x768  
1280x1024  
1280x1024  
1600x1200  
1600x1200  
76, 85  
3D Mode  
Refresh Rate (Hz)  
SE7210TP1-E 3D Video Mode Support with Z Buffer Enabled  
640x480  
60,72,75,90,100  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
800x600  
60,70,75,90,100  
60,72,75,90,100  
43,60,70,72  
Supported  
Supported  
Supported  
Supported  
1024x768  
1280x1024  
1600x1200  
60,66,76,85  
3D Mode  
Refresh Rate (Hz)  
SE7210TP1-E 3D Video Mode Support with Z Buffer Disabled  
640x480  
60,72,75,90,100  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
800x600  
60,70,75,90,100  
60,72,75,90,100  
43,60,70,72  
Supported  
Supported  
1024x768  
1280x1024  
1600x1200  
60,66,76,85  
3.4.8.2  
Video Memory Interface  
The memory controller subsystem of the Rage XL arbitrates requests from direct memory  
interface, the VGA graphics controller, the drawing coprocessor, the display controller, the video  
scalar, and hardware cursor. Requests are serviced in a manner that ensures display integrity  
and maximum CPU/coprocessor drawing performance.  
The SE7210TP1-E supports an 8 MB SDRAM device for video memory.  
3.4.9  
Network Interface Controller (NIC) Subsystem  
The Intel Server Board SE7210TP1-E supports two Network Interface Controllers (NICs), one  
that runs at 10/100Mb and is based on the Intel 82551QM NIC and the other that runs at one  
gigabit and is based on the Intel 82547GI NIC. When looking at the rear of the chassis, the  
gigabit NIC is at the right (closest to the video port) and the 10/100Mb NIC is at the left. The  
32  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Intel Server Board SE7210TP1-E supports independent disabling of the two NIC controllers  
using the BIOS Setup menu.  
The NIC subsystem consists of the following:  
Intel 82547GI Platform LAN Connect (PLC) device for 10/100/1000 Mbits/sec Ethernet  
LAN connectivity  
Intel 82551QM device for 10/100 Mbits/sec Ethernet LAN connectivity  
RJ-45 LAN connector with integrated status LEDs  
The 82547GI is controlled by the CSA interface off of the MCH and supports the following  
features:  
Basic 10/100/1000 Ethernet LAN connectivity  
Integrated Gigabit Ethernet Media Access Control (MAC) and physical layer (PHY)  
IEEE 802.3 10BASE-T/100BASE-TX/1000BASE-T compliant physical layer interface  
IEEE 802.3ab Auto-Negotiation support  
Low power (less than 350mW in active transmit mode)  
Reduced power in “unplugged mode” (less than 50mW)  
Automatic detection of “unplugged mode”  
Communication Streaming Architecture (CSA) port provides higher throughput and lower  
latencies resulting in up to 30% higher bus throughput (up to wire speed)  
Full device driver compatibility  
Programmable transit threshold  
Configuration EEPROM that contains the MAC address  
Teaming and Fail over support  
The 82551QM is controlled by the 6300ESB I/O and supports the following features:  
Integrated IEEE 802.3 10BASE-T and 100BASE-TX compatible PHY  
32-bit PCI/CardBus master interface  
Modem interface for combination solutions  
Integrated power management functions  
Full Duplex support at both 10 and 100 Mbps  
IEEE 802.3u Auto-Negotiation support  
3 Kbyte transmit and 3 Kbyte receive FIFOs  
Fast back-to-back transmission support with minimum interframe spacing  
IEEE 802.3x 100BASE-TX Flow Control support  
Advanced Power management capabilities  
Low power 3.3 V device  
Efficient dynamic standby mode  
Deep power down support  
Clockrun protocol support  
33  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Wired for Management support  
Integrated Alert on LAN* 2 Support  
ACPI and PCI Power Management standards compliance  
Wake on "interesting" packets and link status change support  
Remote power up support  
Additional features of the NIC subsystem include:  
PCI bus master interface  
CSMA/CD protocol engine  
PCI power management  
Supports ACPI technology  
Supports LAN wake capabilities  
3.4.9.1  
RJ-45 LAN Connectors with Integrated LEDs  
Two LEDs are built into each RJ-45 LAN connector (as shown in Figure 9). For the 82551QM  
NIC, the green LED indicates a link to the LAN and the green LED indicates the connection  
speed. Table 10 describes the LED states when the board is powered up and the 10/100  
Ethernet LAN subsystem is operating.  
Table 10. 10/100 Ethernet LAN Connector LEDs  
LED  
Left  
LED Color  
LED State  
Indicates  
Green  
Off  
On  
Off  
10 Mbit/sec data rate is selected.  
100 Mbit/sec data rate is selected.  
LAN link is not established.  
LAN link is established.  
Right  
Green  
On (steady state)  
On (brighter and pulsing) The server is communicating with another  
computer on the LAN.  
Table 11 describes the LED states when the board is powered up and the 10/100/1000  
Mbits/sec LAN subsystem is operating.  
Figure 9. LAN Connector LED Locations  
Table 11. 10/100/1000 LAN Connector LED States  
LED  
Left  
Color  
LED State  
Condition  
Green  
Off  
LAN link is not established.  
34  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
On (steady state)  
LAN link is established.  
On (brighter and pulsing)  
The server is communicating with another  
computer on the LAN.  
Off  
On  
On  
10 Mbit/sec data rate is selected.  
100 Mbit/sec data rate is selected.  
1000 Mbit/sec data rate is selected.  
Green  
Right  
Orange  
3.4.10  
USB 2.0 Support  
The USB controller functionality integrated into 6300ESB I/O provides the baseboard with the  
interface for up to four USB 2.0 ports. Three external connectors are located on the back edge  
of the baseboard. One internal 2x5 header is provided, capable of supporting an additional  
optional connector.  
3.4.11  
I/O Controller  
The Winbond* W83627HF-AW I/O Controller provides the following features:  
Two serial ports  
Serial IRQ interface compatible with serialized IRQ support for PCI systems  
PS/2-style mouse and keyboard interfaces  
Interface for one 1.44 MB diskette drive  
Intelligent power management, including a programmable wake-up event interface  
PCI power management support  
The BIOS Setup program provides configuration options for the I/O controller.  
For information about  
WINBOND W83627HF-AW I/O controller  
Refer to  
http://www.Winbond.com  
3.4.11.1  
Serial Ports  
The Intel Server Board SE7210TP1-E has one 9-pin D-sub serial port connector and one 2 x 5  
serial port header. The serial port A connector is located in the rear I/O area. The serial port B  
header is located near serial port A. Two high-speed 16550 compatible UARTs with 16-byte  
send/receive FIFOs.  
For information about  
Refer to  
Table 80  
Figure 1  
Table 81  
The signal names of the serial port A connector  
The location of the serial port B header  
The signal names of the serial port B header  
3.4.11.2  
Floppy Disk Controller  
The floppy disk controller of the W83627HF-AW integrates all of the logic required for floppy  
disk control. The FDC implements a PC/AT or PS/2 solution.  
35  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
For information about  
The location of the diskette drive connector  
The signal names of the diskette drive connector  
Refer to  
Figure 1  
Section 7.9  
3.4.11.3  
Keyboard and Mouse Interface  
PS/2 keyboard and mouse connectors are located on the back panel. The +5 V lines to these  
connectors are protected with a PolySwitch* fuse circuit that, like a self-healing fuse,  
reestablishes the connection after an overcurrent condition is removed.  
NOTE  
The keyboard is supported in the bottom PS/2 connector and the mouse is supported in the top  
PS/2 connector. Power to the server should be turned off before a keyboard or mouse is  
connected or disconnected.  
The keyboard controller contains the American MegaTrends* (AMI) keyboard and mouse  
controller code, provides the keyboard and mouse control functions, and supports password  
protection for power-on/reset. A power-on/reset password can be specified in the BIOS Setup  
program.  
For information about  
Refer to  
The location of the keyboard and mouse connectors  
The signal names of the keyboard and mouse connectors  
Section 3.4.11.3  
Table 82  
3.4.11.4  
Wake Up Control  
The I/O controller contains functionality that allows various events to control the power-on and  
power-off the system.  
3.5 Configuration and Initialization  
This section describes the initial programming environment including address maps for memory  
and I/O, techniques and considerations for programming ASIC registers, and hardware options  
configuration.  
3.5.1  
Memory Space  
Table 12. System Memory Map  
Address Range  
Address Range  
(hex)  
100000 - FFFFFFFF 4095 MB  
Size  
Description  
(decimal)  
1024 K - 4194304 K  
Extended memory  
Runtime BIOS  
Reserved  
960 K - 1024 K  
896 K - 960 K  
800 K - 896 K  
640 K - 800 K  
639 K - 640 K  
F0000 - FFFFF  
E0000 - EFFFF  
C8000 - DFFFF  
A0000 - C7FFF  
9FC00 - 9FFFF  
64 KB  
64 KB  
96 KB  
160 KB  
1 KB  
Available high DOS memory (open to the PCI bus)  
Video memory and BIOS  
Extended BIOS data (movable by memory manager  
software)  
36  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
512 K - 639 K  
0 K - 512 K  
80000 - 9FBFF  
00000 - 7FFFF  
127 KB  
512 KB  
Extended conventional memory  
Conventional memory  
3.5.1.1  
PCI Configuration Space Map  
Table 13. PCI Configuration Space Map  
Bus  
Device  
Number (hex)  
00  
Function  
Number (hex)  
00  
Number (hex)  
Description  
00  
Memory controller of Intel E7210 component  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
01  
02  
02  
02  
02  
02  
02  
02  
01  
1E  
1F  
1F  
1F  
1F  
1F  
1D  
1D  
1D  
1D  
00  
08  
00  
01  
02  
03  
04  
06  
00  
00  
00  
01  
03  
05  
06  
00  
01  
02  
07  
00  
00  
00  
00  
00  
00  
00  
00  
Hub link to PCI bridge  
Intel 82801ER 6300ESB I/O PCI-to-LPC bridge  
IDE controller  
SMBus controller  
modem controller (optional)  
USB UHCI controller 1  
USB UHCI controller 2  
USB UHCI controller 3  
EHCI controller  
LAN controller  
PCI bus connector 1  
PCI bus connector 2  
PCI bus connector 3  
PCI bus connector 4  
PCI bus connector 5  
SATA/SATA RAID  
3.5.2  
I/O Map  
Table 14. I/O Map  
Address (hex)  
Size  
Description  
0000 - 00FF  
256 bytes  
Used by the Server Board SE7210TP1-E. Refer to the 6300ESB I/O  
data sheet for dynamic addressing information.  
0170 - 0177  
01F0 - 01F7  
8 bytes  
8 bytes  
8 bytes  
8 bytes  
8 bytes  
8 bytes  
1 byte  
Secondary IDE channel  
Primary IDE channel  
0228 - 022F (Note 1)  
0278 - 027F (Note 1)  
02E8 - 02EF (Note 1)  
02F8 - 02FF (Note 1)  
0376  
COM4/video (8514A)  
COM2  
Secondary IDE channel command port  
Secondary IDE channel status port  
0377, bits 6:0  
7 bits  
37  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Description  
Address (hex)  
0378 - 037F  
Size  
8 bytes  
12 bytes  
32 bytes  
8 bytes  
6 bytes  
1 byte  
03B0 - 03BB  
03C0 - 03DF  
03E8 - 03EF  
03F0 - 03F5  
03F6  
Intel E7210 MCH  
Intel E7210 MCH  
Diskette channel 1  
Primary IDE channel command port  
COM1  
03F8 - 03FF  
04D0 - 04D1  
LPTn + 400  
0CF8 - 0CFB (Note 2)  
0CF9 (Note 3)  
0CFC - 0CFF  
FFA0 - FFA7  
FFA8 - FFAF  
Notes:  
8 bytes  
2 bytes  
8 bytes  
4 bytes  
1 byte  
4 bytes  
8 bytes  
8 bytes  
Edge/level triggered PIC  
PCI configuration address register  
Reset control register  
PCI configuration data register  
Primary bus master IDE registers  
Secondary bus master IDE registers  
1. Default, but can be changed to another address range  
2. Dword access only  
3. Byte access only  
3.5.2.1  
Device Number and IDSEL Mapping  
Each device under the PCI hub bridge has its IDSEL signal connected to one bit of AD[31:16],  
which acts as a chip select on the PCI bus segment in configuration cycles. This determines a  
unique PCI device ID value for use in configuration cycles. The following table shows each IDSEL  
value for the PCI bus devices and the corresponding device description.  
38  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Functional Architecture  
Table 15. PCI Bus Configuration IDs  
IDSEL Value  
18  
Device  
PCI slot 6 (closest to middle of the board)  
20  
19  
18  
16  
17  
PCI slot 3 (middle slot)  
PCI slot 2 (middle slot)  
PCI slot 1 (closest to left edge of board)  
ATI Rage XL Video Controller  
Single channel U320 controller Adaptec 7901  
3.6 Clock Generation and Distribution  
All buses on the SE7210TP1-E baseboard operate using synchronous clocks. Clock  
synthesizer/driver circuitry on the baseboard generates clock frequencies and voltage levels as  
required, including the following:  
66 MHz at 3.3 V logic levels: For the E7210, 6300ESB I/O and 82547GI clocks.  
14.318 MHz at 3.3V logic levels: 6300ESB I/O and VGA  
100/133-MHz host clock generator for processor, MCH, Memory DIMMs, and the ITP.  
48-MHz clock for Super I/O and USB.  
33.3-MHz PCI reference clock.  
Note: The clock for memory DIMMs come from Intel® 827210 Memory Controller Hub (MCH).  
39  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4. System BIOS  
This section details the functionality and features supported by the Intel® Server Board  
SE7210TP1-E Basic Input/Output System (BIOS), which is based on an AMI 8.0 core  
architecture. The BIOS is implemented as firmware that resides in a Flash ROM. It provides  
hardware-specific initialization algorithms and standard PC-compatible basic input/output (I/O)  
services, and standard Intel server board features. The Flash ROM also contains firmware for  
certain embedded devices.  
The SE7210TP1-E BIOS is comprised of the following components:  
IA-32 core BIOS. This component contains most of the standard services and  
components found in an IA-32 system, such as the PCI Resource manager, ACPI  
support, POST, and RUNTIME functionality.  
Server BIOS extensions: Support for the National Semiconductor PC87431 integrated  
management controller and Intelligent Platform Management Interface (IPMI).  
Processor Microcode Updates: The BIOS also includes latest processor microcode  
updates.  
The following table provides a list of all the features supported by the system BIOS.  
Table 16: Supported BIOS Features  
ID  
Feature Name  
Support at least 128KB of available option space  
(C0000h ~ E0000h).  
Comments  
Support Option ROM available space in address  
(C0000h~DFFFFh - total 128K).  
Support Wired for Management specification as  
Now added to the Microsoft* Windows* Logo Program  
System and Device Requirements 2.0 document.  
required to obtain WHQL compliance.  
PXE 2.1 (or higher) for on-board network controllers.  
Both NIC controllers have:  
PXE2.1 support  
PXE optional ROM with no setup screen  
Support Boot Integrity Services (BIS). Security  
handshake on PXE.  
UUID - UUID support (open standard in PXE  
UUID is written during manufacturing.  
environment).  
Wake up  
RTC (real time clock): S1/S4  
PME: S1/S4/S5  
PS2 KB/MS: S1  
USB: S1  
Power button: S1/S4/S5  
USB Boot  
USB boot support for USB 1.1/2.0 legacy compliant  
hard disk, CD-ROM, floppy drives, and disk-on-key.  
40  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
ID  
Feature Name  
Support for BIOS recovery.  
Comments  
LS120/LS240  
USB bootable devices such as disk-on-key  
(USB 1.1/2.0)  
USB CD-ROM(1.1/2.0)  
ATAPI CD-ROM  
ATAPI DVD  
Support for legacy/USB floppy only due to  
BIOS image size (1MB).  
Legacy USB device support.  
Legacy USB KB/MS  
Implemented by SMI  
Post Code/Port 80 Capture: Support POST Progress  
FIFO feature. Will be able to capture all POST Codes  
and Port 80 codes for debugging with onboard LEDs.  
Supported via onboard LEDs.  
POST check points are logged in the National  
Semiconductor PC87431 integrated management  
controller.  
NMI dump switch support.  
Logging of NMI dump event.  
Front panel NMI button.  
Operating system will log the dump data if NMI  
button is pressed.  
Power Switch Disable: Power switch can be disabled.  
This is supported by the National Semiconductor  
PC87431 integrated management controller through  
IPMI commands.  
BIOS Boot Block: BIOS will have a segregated boot  
block enabling recovery of a corrupted BIOS. Will have  
BIOS Recovery Jumper.  
Force BIOS recovery by jumper or when BIOS  
corruption is detected.  
Protect boot block by using the block lock feature built  
into the flash device.  
BIOS Update: Enable Flash BIOS update and allow  
updates from network drives in DOS and via PXE.  
Support for CD-ROM, USB storage and network,  
except for floppy.  
Chassis intrusion detection.  
LDCM will detect chassis intrusion state, and notify  
administrator via network.  
Hardware support for monitoring voltages, temperature, Supported by National Semiconductor PC87431  
and fans.  
integrated management controller.  
BIOS Setup will provide options to disable onboard I/O  
peripheral components (LAN components, Serial ATA,  
SCSI, etc.). When disabled, these components are to  
be completely removed from the PCI address space,  
making them invisible to any loaded operating system.  
Must be able to disable embedded video (ATI* RAGE  
XL), SCSI (LSI* 53C1030), ICH5R serial ATA, and  
NIC controllers.  
BIOS Setup will provide options to disable/enable  
Enable/disable Option ROMs by BIOS setup.  
Option ROMs of onboard devices and PCI slots.  
Ability to store error events in non-volatile space.  
System stores events via National Semiconductor  
PC87431 integrated management controller.  
Support for Split Option ROM, based on PCI-SIG PCI  
Firmware Specification Revision 3.0.  
Active thermal management to minimize noise at the  
Supported via the National Semiconductor PC87431  
integrated management controller.  
system level. Will adhere to acoustic specifications.  
Factory Automation support. This includes the ability to  
upgrade/update FW, BIOS, CMOS settings, OEM  
splash screen image, FRU/SDR and HSC code  
remotely (over a LAN) using automated tools in a  
volume production environment.  
NMI detection.  
Ability to detect parity/system errors on all PCI buses.  
Ability to detect single/double bit errors.  
41  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
ID  
Feature Name  
Support for the sleep button.  
Comments  
Support for clear password by jumper.  
Support for clear CMOS by jumper.  
Support for IPMP1.5.  
National Semiconductor PC87431 integrated  
management controller only.  
Support for Intel diagnostic LEDs.  
Support for serial console redirection.  
Support for LAN console redirection.  
Support for FRU LEDs.  
COM A / COM B  
Intel 82546GI  
Support for FRB1 / FRB2.  
Support for memory.  
DDR266/DDR333/DDR400 supported.  
Max memory size: 4GB  
CPU Support.  
Hyper-threading: enable/disable by BIOS  
setup.  
CPU microcode update during POST.  
CPU micro code update during runtime: POST  
and runtime (Int 15h, AX= 0D042h).  
Allow variable size microcode update  
(maximum microcode size is 16KB).  
Support for BBS.  
Support for PCI.  
BBS Rev. 1.02  
PCI  
PCI-X  
PCI-X DDR  
Support for MPS (APIC mode).  
Support for PIC mode.  
Support for ACPI.  
MPS 1.4 (MPS table)  
PCI IRQ routing table  
ACPI 2.0 / 1.0b  
S0/S1/S4/S5  
ACPI SPCR (Serial Port Console Redirection)  
table  
Support for SMBIOS.  
Support for keyboard and mouse swap.  
SMBIOS 2.3.1, below 1 MB in memory.  
AMI firmware  
BIOS warning messages in English, assuming video is  
available instead of beep codes.  
Multi-language ready.  
Support for security.  
English, French, Spanish, Italian, German  
PS/2 KB and MS lock  
Floppy write protection  
Password protection  
Quiet boot during POST  
Quick boot during POST  
Console-free boot  
Support for boot.  
Boot menu  
Support for Alliance BIOS Specification V2.0.  
Windows BIOS update utility.  
Server Management  
Power control in any state (operating system up, down,  
Supported by the National Semiconductor  
hung).  
PC87431 integrated management controller.  
42  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
ID  
Feature Name  
Sensor monitoring and fault alerting while operating  
system is present.  
Comments  
Supported by the National Semiconductor  
PC87431 integrated management controller.  
Fault alerting via local or via LAN while operating  
system present.  
Supported by the National Semiconductor  
PC87431 integrated management controller.  
IPMI / DMI / CIM compliant.  
IPMI 1.5, DMI, and CIM  
Full IPMI 1.5 for server module  
Subset of IPMI 1.5 for onboard National  
Semiconductor PC87431 integrated  
management controller.  
Integration with ISM software.  
Security features to protect unwanted tampering of the  
server.  
LDCM provides chassis intrusion and hardware and  
software change reporting.  
4.1 BIOS Identification String  
The BIOS Identification string is used to uniquely identify the revision of the BIOS being used on  
the system. The string is formatted as follows:  
BoardId.OEMID.BuildType.Major.Minor.BuildID.BuildDateTime  
where:  
BoardID  
OEMID  
= up to 10 character ID. SE7210TP10  
= 3 character OEM ID. 86B is used for Intel EPSD.  
BuildType = where xx=2 digit number and:  
Dxx = Development  
Xxx = Power On  
Axx = Alpha BIOS  
Bxx = Beta BIOS  
RCxx = Release Candidate  
Pxx = Production  
Major = The major revision identifies the feature set corresponding  
to this BIOS release.  
Minor = The minor revision identifies the feature set corresponding  
to this BIOS release.  
BuildID = 4 decimal digit build number, starting with "0000".  
BuildDateTime = Build date and time in MMDDYYYYHHMM format.  
43  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.2 Flash ROM  
The Intel 82802AC Firmware Hub (FWH) includes an 8 megabit symmetrical flash memory  
device. Internally, the device is grouped into eight 64-KB blocks that are individually erasable,  
lockable, and unlockable.  
4.2.1  
Removable Media Support  
The BIOS supports removable media devices, including 1.44MB floppy removable media  
devices and optical devices such as a CD-ROM drive or DVD drive. The BIOS supports booting  
from USB mass storage devices connected to the chassis USB port, such as a USB key device.  
The BIOS supports USB 2.0 media storage devices that are backward compatible to the USB  
1.1 specification.  
4.2.2  
Legacy USB  
Legacy USB support enables USB devices such as keyboard, mice, and hubs to be used even  
when the operating system’s USB drivers are not yet available. Legacy USB support is used to  
access the BIOS Setup program, and to install an operating system that supports USB. By  
default, Legacy USB support is set to Enabled.  
Legacy USB support operates as follows:  
1. When the user applies power to the server, legacy support is disabled.  
2. POST begins.  
3. Legacy USB support is enabled by the BIOS allowing the user to use a USB keyboard to  
enter and configure the BIOS Setup program and the maintenance menu.  
4. POST completes.  
5. The operating system loads. While the operating system is loading, USB keyboard and  
mice are recognized and may be used to configure the operating system. (Keyboard and  
mice are not recognized during this period if Legacy USB support was set to disabled in  
the BIOS Setup program.)  
6. After the operating system loads the USB drivers, all legacy and non-legacy USB  
devices are recognized by the operating system, and Legacy USB support from the  
BIOS is no longer used.  
To install an operating system that supports USB, verify that Legacy USB support in the BIOS  
Setup program is set to Enabled and follow the operating system’s installation instructions.  
NOTE  
Legacy USB support is for keyboard, mice, and hubs only. Other USB devices are not  
supported in legacy mode.  
44  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.3 Resource Configuration  
4.3.1  
PCI Autoconfiguration  
The BIOS can automatically configure PCI devices. PCI devices may be on-board or add-in  
cards. Autoconfiguration lets a user insert or remove PCI cards without having to configure the  
system. When a user turns on the system after adding a PCI card, the BIOS automatically  
configures interrupts, the I/O space, and other system resources. Any interrupts set to Available  
in Setup are considered to be available for use by the add-in card. Autoconfiguration information  
is stored in ESCD format.  
4.3.2  
PCI IDE Support  
If Auto is selected from the BIOS Setup program, the BIOS automatically sets up the two  
PCI IDE connectors with independent I/O channel support. The IDE interface supports hard  
drives up to ATA-66/100 and recognizes any ATAPI compliant devices, including CD-ROM  
drives, tape drives, and Ultra DMA. The BIOS determines the capabilities of each drive and  
configures them to optimize capacity and performance.  
To take advantage of the high capacities typically available today, hard drives are automatically  
configured for Logical Block Addressing (LBA) and to PIO Mode 3 or 4, depending on the  
capability of the drive. The user can override the auto-configuration options by specifying  
manual configuration in the BIOS Setup program.  
To use ATA-66/100 features the following items are required:  
An ATA-66/100 peripheral device  
An ATA-66/100 compatible cable  
ATA-66/100 operating system device drivers  
NOTES  
ATA-66/100 compatible cables are backward compatible with drives using slower IDE  
transfer protocols. If an ATA-66/100 disk drive and a disk drive using any other IDE transfer  
protocol are attached to the same cable, the maximum transfer rate between the drives is  
reduced to that of the slowest device.  
Do not connect an ATA device as a slave on the same IDE cable as an ATAPI master  
device. For example, do not connect an ATA hard drive as a slave to an ATAPI CD-ROM  
drive.  
4.4 System Management BIOS (SMBIOS)  
SMBIOS is a Server Management Interface (SMI) compliant method for managing servers in a  
managed network.  
45  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The main component of SMBIOS is the Management Information Format (MIF) database, which  
contains information about the computing system and its components. Using SMBIOS, a system  
administrator can obtain the system types, capabilities, operational status, and installation dates  
for system components. The MIF database defines the data and provides the method for  
accessing this information. The BIOS enables applications such as third-party management  
software to use SMBIOS. The BIOS stores and reports the following SMBIOS information:  
BIOS data, such as the BIOS revision level  
Fixed-system data, such as peripherals, serial numbers, and asset tags  
Resource data, such as memory size, cache size, and processor speed  
Dynamic data, such as event detection and error logging  
Non-Plug and Play operating systems, such as Windows* NT, require an additional interface for  
obtaining the SMBIOS information. The BIOS supports an SMBIOS table interface for such  
operating systems. Using this support, an SMBIOS service-level application running on a  
non-Plug and Play operating system can obtain the SMBIOS information.  
4.5 BIOS Updates  
The BIOS can be updated with the AMI Flash Utility (AFUDOS.exe), which requires creation of  
a boot diskette and manual rebooting of the system. Using this utility, the BIOS can be updated  
from a file on a 1.44 MB diskette (from a legacy diskette drive or an LS-120 diskette drive) or a  
CD-ROM. Please refer to the SE7210TP1-E BIOS EPS for details.  
It supports the following BIOS maintenance functions:  
Verifying that the updated BIOS matches the target system to prevent accidentally  
installing an incompatible BIOS.  
Updating both the BIOS boot block and the main BIOS. This process is fault tolerant to  
prevent boot block corruption.  
Changing logo utility.  
NOTE  
Review the instructions distributed with the upgrade utility before attempting a BIOS update.  
4.6 Recovering BIOS Data  
Some types of failure can destroy the BIOS. For example, the data can be lost if a power outage  
occurs while the BIOS is being updated in flash memory. The BIOS can be recovered from a  
diskette using the BIOS recovery mode. When recovering the BIOS, be aware of the following:  
Because of the small amount of code available in the non-erasable boot block area,  
there is video support. The user can only monitor this procedure by listening to the  
speaker or looking at the diskette drive LED.  
The recovery process may take several minutes; larger BIOS flash memory devices  
require more time.  
Two beeps and the end of activity in the diskette drive indicate successful BIOS  
recovery.  
A series of continuous beeps indicates a failed BIOS recovery.  
46  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
To create a BIOS recovery diskette, a bootable diskette must be created and the BIOS update  
files copied to it. BIOS upgrades and the AMI Flash Utility are available from Intel Customer  
Support through the Intel World Wide Web site.  
NOTE  
Even if the server is configured to boot from an LS-120 diskette (in the Setup program’s  
Removable Devices submenu), the BIOS recovery diskette must be a standard 1.44 MB  
diskette not a 120 MB diskette.  
4.7 BIOS POST  
The BIOS supports one system splash screen. When the system is booting, the BIOS will  
display the splash screen instead of BIOS messages. BIOS messages can be viewed by  
pressing the ‘ESC’ key during POST. Once the BIOS POST message screen is selected, the  
splash screen is no longer accessible during the current boot sequence. The splash screen can  
be customized by with the ‘Change Logo’ utility. Refer to the Change Logo for AMIBIOS User’s  
Guide (Version 2.22) for details.  
4.7.1  
User Interface  
There are two types of consoles used for displaying the user interface: graphical or text based.  
Graphics consoles are in 640x480x8bpp mode; text consoles are 80x25.  
Console output is partitioned into three areas: the System Activity/State, Logo/Diagnostic, and  
Current Activity windows. The System Activity Window displays information about the current  
state of the system, such as if it is active, hung, or requires user intervention. The  
Logo/Diagnostic Window displays the OEM splash screen logo or a diagnostic boot screen. The  
Current Activity Window displays information about the currently executing portion of POST as  
well as user prompts or status messages.  
If the CMOS is corrupt, the BIOS displays the following message:  
“Press F1 to load default values and continue  
Press F2 to run SETUP”.  
The BIOS always wait until <F1> or <F2> is pressed; Or always not wait if [POST Error Pause]  
is set disabled in BIOS setup.  
47  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The BIOS displays the following information during POST:  
Copyright message  
BIOS ID  
Current processor configuration  
Installed physical memory size  
Current activity and user intervention  
4.8 BIOS Setup Utility  
The BIOS Setup utility is provided to perform system configuration changes and to display  
current settings and environment information.  
The BIOS Setup utility stores configuration settings in system non-volatile storage. Changes  
affected by BIOS Setup will not take effect until the system is rebooted. The BIOS Setup Utility  
can be accessed when prompted during POST by using the F2 key.  
4.8.1  
Localization  
The BIOS Setup utility uses the Unicode standard and is capable of displaying setup forms in  
the languages currently included in the Unicode standard: English, French, Italian, German, and  
Spanish. Intel provides translations for console strings in the supported languages. The  
language can be selected using the BIOS user interface.  
4.8.2  
Keyboard Commands  
The Keyboard Command Bar supports the following:  
Table 17: BIOS Setup Keyboard Command Bar Options  
Description  
Key  
Option  
Enter Execute Command The Enter key is used to activate sub-menus when the selected feature is a sub-menu,  
or to display a pick list if a selected option has a value field, or to select a sub-field for  
multi-valued features like time and date. If a pick list is displayed, the Enter key will  
undo the pick list, and allow another selection in the parent menu.  
ESC  
Exit  
The ESC key provides a mechanism for backing out of any field. This key will undo the  
pressing of the Enter key. When the ESC key is pressed while editing any field or  
selecting features of a menu, the parent menu is re-entered.  
When the ESC key is pressed in any sub-menu, the parent menu is re-entered. When  
the ESC key is pressed in any major menu, the exit confirmation window is displayed  
and the user is asked whether changes can be discarded. If “No” is selected and the  
Enter key is pressed, or if the ESC key is pressed, the user is returned to where they  
were before ESC was pressed without affecting any existing any settings. If “Yes” is  
selected and the Enter key is pressed, setup is exited and the BIOS continues with  
POST.  
Select Item  
The up arrow is used to select the previous value in a pick list, or the previous options  
in a menu item's option list. The selected item must then be activated by pressing the  
Enter key.  
Select Item  
Select Menu  
Select Field  
The down arrow is used to select the next value in a menu item’s option list, or a value  
field’s pick list. The selected item must then be activated by pressing the Enter key.  
The left and right arrow keys are used to move between the major menu pages. The  
keys have no affect if a sub-menu or pick list is displayed.  
Tab  
The Tab key is used to move between fields. For example, Tab can be used to move  
from hours to minutes in the time item in the main menu.  
48  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Key  
Option  
Description  
-
Change Value  
The minus key on the keypad is used to change the value of the current item to the  
previous value. This key scrolls through the values in the associated pick list without  
displaying the full list.  
+
Change Value  
Setup Defaults  
The plus key on the keypad is used to change the value of the current menu item to the  
next value. This key scrolls through the values in the associated pick list without  
displaying the full list. On 106-key Japanese keyboards, the plus key has a different  
scan code than the plus key on the other keyboard, but will have the same effect  
F9  
Pressing F9 causes the following to appear:  
Setup Confirmation  
Load default configuration now?  
[Yes]  
[No]  
If “Yes” is selected and the Enter key is pressed, all Setup fields are set to their default  
values. If “No” is selected and the Enter key is pressed, or if the ESC key is pressed,  
the user is returned to where they were before F9 was pressed without affecting any  
existing field values  
F10  
Save and Exit  
Pressing F10 causes the following message to appear:  
Setup Confirmation  
Save Configuration changes and exit now?  
[Yes]  
[No]  
If “Yes” is selected and the Enter key is pressed, all changes are saved and Setup is  
exited. If “No” is selected and the Enter key is pressed, or the ESC key is pressed, the  
user is returned to where they were before F10 was pressed without affecting any  
existing values.  
4.8.3  
Entering BIOS Setup  
The BIOS Setup utility is accessed by pressing the <F2> hotkey during POST.  
4.8.4  
Menu Selection  
The first screen displayed when entering the BIOS Setup Utility is the Main Menu selection  
screen. This screen displays the major menu selections available. The following tables describe  
the available options on the top-level and lower level menus. Default values are highlighted.  
4.8.4.1  
Main Menu  
To access this menu, select Main on the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
49  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Table 18 describes the BIOS setup main menu options. This menu reports processor and  
memory information and is for configuring the system date and system time.  
Table 18: BIOS Setup Main Menu Options  
Feature  
Options  
Description  
Server BIOS: Version  
Build Date  
No option  
BIOS version, date and ID  
ID  
Processor: Type  
Speed  
No option  
CPU type, speed, count  
Count  
System Memory: Size  
No option  
Memory Size  
System time  
System date  
Current time  
Current date  
Displays the current time.  
Displays the current date.  
4.8.4.2  
Advanced Menu  
To access this menu, select Advanced on the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
Table 19 describes the Advanced Menu. This menu is used for setting advanced features that  
are available through the chipset.  
Table 19. Advanced Menu  
Feature  
Options  
Submenu  
Description  
CPU Configuration.  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
Submenu  
Submenu  
Submenu  
Submenu  
Submenu  
Configure the IDE device(s).  
Configure the Floppy drive(s).  
Configure Super I/O Chipset Win627.  
Configure the USB support.  
Configure the PCI support.  
50  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.4.3  
CPU Configuration Submenu  
To access this submenu, select Advanced on the menu bar, then CPU Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 20 is for configuring the CPU.  
Table 20. CPU Configuration Submenu  
Feature  
Options  
Description  
No options  
Manufacturer  
Brand String  
Frequency  
FSB Speed  
CPU ID  
Cache L1  
Cache L2  
Max CPUID Value Limit  
CPU Manufacturer  
CPU Brand String  
CPU Frequency  
No options  
No options  
No options  
No options  
No options  
No options  
Disable (default)  
Enable  
FSB Speed  
CPU stepping identification  
Display Cache L1 size  
Display Cache L2 size  
This should be enabled order to boot legacy OSes that  
cannot support CPUs with extended CPUID functions.  
Disable  
Enable (default)  
Hyper Threading  
Technology  
This option is only available if the installed CPU is capable of  
Hyper Threading Technology support.  
51  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.4.4  
IDE Configuration Submenu  
To access this submenu, select Advanced on the menu bar, then IDE Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 21 is for IDE Configuration.  
Table 21. IDE Configuration Submenu  
Feature  
Options  
Description  
ATA Configuration  
[DISABLE PATA/SATA]  
Select ATA mode to change bellow ATA configuration.  
[CONFIG PATA & SATA]  
(default)  
[CONFIG SATA ATA]  
[LEGACY ATA CONFIG  
[ENABLE SATA RAID]  
Submenu  
Map PATA to Legacy  
ATA, Config SATA.  
The item will be present when selecting CONFIG  
PATA & SATA in ATA Configuration.  
Map SATA to Legacy  
ATA, Disable PATA  
Map PATA & SATA to  
Legacy ATA  
Submenu  
Submenu  
Submenu  
The item will be present when selecting CONFIG  
SATA ATA in ATA Configuration.  
The item will be present when selecting LEGACY ATA  
CONFIG in ATA Configuration.  
The item will be present when selecting ENABLE  
SATA RAID in ATA configuration.  
Enable SATA  
RAID, & Map PATA to  
Legacy ATA  
>Primary IDE Master  
>Primary IDE Slave  
>Secondary IDE Master  
>Secondary IDE Slave  
>Third IDE Master  
Submenu  
Submenu  
Submenu  
Submenu  
Submenu  
When BIOS auto detects the presence of IDE devices,  
Setup will display the status of auto-detection of IDE  
devices.  
>Fourth IDE Master  
Submenu  
Hard Disk Write Protect  
Disable (default)  
Enable  
Enable write protection.  
52  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Feature  
Options  
Description  
IDE Detect Time Out  
(Sec)  
0  
5  
Select time out value for ATA/ATAPI.  
10  
15  
20  
25  
30  
35(default)  
Host & Device (default)  
Host  
ATA (PI) 80Pin Cable  
Detection  
Select the mechanism for detecting 80pin ATA.  
Device  
4.8.4.4.1  
Map PATA to Legacy ATA, Config SATA Sub-menu Selections  
To access this menu, select Advanced on the menu bar, then IDE Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 22 is used to configure the IDE Configuration.  
Table 22. Primary/Secondary/Third/Fourth Master/Slave Submenu  
Feature  
Options  
Description  
Enabled (default)  
SATA Control  
Enhanced  
If enabled, PATA ports may use the primary  
and/or secondary ATA channel addresses and the  
SATA ports are limited to using the third and  
fourth ATA channel addresses. If disabled, the  
SATA ports are not available.  
Disabled  
Primary  
Secondary  
Both (default)  
A1-3rd, A2-4th. (default)  
A1-4th, A2-3rd.  
P-ATA Channel  
Selection  
Selection determines assignment of only primary,  
only secondary or both ATA channel addresses  
for the PATA ports.  
S-ATA Ports Definition  
This option allows swapping of port mappings  
between the third and fourth ATA channels for the  
SATA ports.  
4.8.4.4.2  
Map SATA to Legacy ATA, Disable PATA Sub-menu Selections  
To access this menu, select Advanced on the menu bar, then IDE Configuration.  
53  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 23 is used to configure the IDE Configuration.  
Table 23. Primary/Secondary/Third/Fourth Master/Slave Submenu  
Feature  
Options  
Description  
A1-PRI, A2-SEC. (default)  
S-ATA Ports Definition  
This option allows swapping of port mappings  
between the third and fourth ATA channels for the  
SATA ports.  
A1-SEC, A2-PRI.  
4.8.4.4.3  
Map PATA & SATA to Legacy ATA Sub-menu Selections  
To access this menu, select Advanced on the menu bar, then IDE Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 24 is used to configure the IDE Configuration.  
Table 24. Primary/Secondary/Third/Fourth Master/Slave Submenu  
Feature  
Options  
Description  
PATA-PRI, SATA-SEC. (default)  
Combined Mode  
Option  
The PATA port is assigned the primary or  
secondary ATA channel addresses; the SATA port  
is assigned the remaining channel address.  
PATA-SEC, SATA-PRI  
4.8.4.4.4  
54  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.4.4.5  
Enable SATA RAID, & Map PATA to Legacy ATA Sub-menu Selections  
To access this menu, select Advanced on the menu bar, then IDE Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented by Table 25 is used to configure the IDE Configuration.  
Table 25. Primary/Secondary/Third/Fourth Master/Slave Submenu  
Feature  
Options  
Description  
Primary  
P-ATA Channel  
Selection  
Selection determines assignment of only primary,  
only secondary or both ATA channel addresses  
for the PATA ports.  
Secondary  
Both (default)  
4.8.4.4.6  
Primary/Secondary/Third/Fourth Master/Slave Submenus  
To access these submenus, select Advanced on the menu bar, then Drive Configuration, and  
then the master or slave to be configured.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration>DMI Event Logging  
>PCI Configuration>USB Configuration  
There are four IDE submenus: primary master, primary slave, secondary master, and secondary  
slave. Table 26 shows the format of the IDE submenus. For brevity, only one example is shown.  
Table 26. Primary/Secondary/Third/Fourth Master/Slave Submenu  
Feature  
Type  
Options  
Description  
Not Installed  
Auto (default)  
CDROM  
ARMD  
Select the type of device connected to the system.  
55  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Feature  
LBA/Large Mode  
Options  
Auto (default)  
Disable  
Description  
Enable LBA Mode if the device supports it.  
Disabled  
Auto (default)  
Block Mode  
PIO Mode  
This option can be changed only if User is selected as the type.  
This option can be changed only if User is selected as the type.  
Auto (default)  
0  
1  
2  
3  
4  
This option can be changed only if User is selected as the type.  
If Auto is selected, this option is not displayed.  
Enables or disables Self-monitoring, Analysis, and Reporting  
Technology.  
S.M.A.R.T  
Auto (default)  
Disabled  
Enabled  
32Bit Data Transfer  
Disabled (default)  
Enabled  
Enable 32-bit Data Transfer.  
4.8.4.5  
Floppy Configuration Submenu  
To access this submenu, select Advanced on the menu bar, then Floppy Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented in Table 27 is the Floppy Configuration Submenu.  
Table 27. Floppy Configuration Submenu  
Feature  
Options  
Description  
Floppy A  
Disabled  
720 KB  
1.44 MB  
2.88 MB  
Disable  
Enable  
Specifies the capacity and physical size of diskette drive A.  
Note: 720Kb & 2.88Mb drives will be as “Untestable”.  
3½ inch  
3½ inch (default)  
3½ inch  
Onboard floppy  
controller  
56  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.4.6  
Super I/O Configuration Submenu  
To access this submenu, select Advanced on the menu bar, then Super I/O Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The menu represented in Table 28 is used to configure Super I/O options.  
Table 28. Super I/O Configuration Submenu  
Feature  
Serial PortA Address Disable  
3F8/IRQ4 (default)  
Options  
Description  
Allow BIOS to select serial Port 1 base Addresses.  
3E8/IRQ4  
2E8/IRQ3  
Serial PortB Address Disable  
Allow BIOS to select serial Port 1 base Addresses.  
2F8/IRQ3 (default)  
3E8/IRQ4  
2E8/IRQ3  
4.8.4.7  
USB Configuration Submenu  
To access this menu, select Advanced on the menu bar, then USB Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
57  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The submenu represented by Table 29 is used to configure the USB features.  
Table 29. USB Configuration Submenu  
Feature  
Options  
Description  
USB Devices Enabled  
USB Function  
NO option  
Disable  
USB device numbers.  
Enable USB HOST control.  
2 USB Ports  
All USB Ports (default)  
Enable (default)  
Disable  
Legacy USB Support  
Support legacy USB.  
Auto  
Enable  
Port 64/60 Emulation  
USB 2.0 Controller  
This option is typically not used since most OSes are  
now USB-aware.  
Disable (default)  
Enable (default)  
Disable  
Support USB2.0.  
FullSpeed  
HiSpeed (default)  
USB 2.0 Controller  
mode  
Configures the USB 2.0 controller in HiSpeed  
(480Mbps) or FullSpeed (12Mbps).  
When USB 2.0 Controller is disabled, it will disappear  
Enable (default)  
Disable  
USB Beep Message  
Enables the beep during USB device enumeration.  
USB Mass Storage  
Device Configuration  
Submenu  
Configure the USB Mass Storage Device Class.  
Only available when USB Mass Storage Device detected in  
system.  
4.8.4.7.1  
BIOS Setup USB Mass Storage Device Configuration Sub-menu Selections  
Table 30. USB Mass Storage Device Configuration Sub-menu Selections  
Feature  
Options  
Help Text  
Description  
USB Mass Storage  
10 Sec  
Number of seconds POST waits for the USB mass  
Reset Delay  
storage device after start unit command.  
20 Sec  
30 Sec  
40 Sec  
N/A  
Device #1  
N/A  
Only displayed if a  
device is detected,  
includes a  
DeviceID string  
returned by the  
USB device.  
Emulation Type  
If Auto is selected, USB devices less than 530MB will be  
emulated as Floppy drives and the remaining as hard  
drives. The Forced FDD option will force a formatted  
HDD to boot as a FDD (Ex. ZIP drive).  
Auto  
Floppy  
Forced  
FDD  
Hard Disk  
CDROM  
58  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Device #n  
N/A  
N/A  
Only displayed if a  
device is detected,  
includes a  
DeviceID string  
returned by the  
USB device.  
Emulation Type  
If Auto is selected, USB devices less than 530MB will be  
emulated as Floppy drives and the remaining as hard  
drives. The Forced FDD option will force a formatted  
HDD to boot as a FDD (Ex. ZIP drive).  
Auto  
Floppy  
Forced  
FDD  
Hard Disk  
CDROM  
4.8.4.8  
PCI Configuration Submenus  
To access this submenu, select Advanced on the menu bar, then PCI Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>CPU Configuration  
>IDE Configuration  
>Floppy Configuration  
>Super I/O Configuration  
>USB Configuration  
>PCI Configuration  
The submenu represented in Table 31 is used for PCI Configuration Submenu.  
Table 31. PCI Configuration Submenu  
Feature  
Options  
Description  
Enable (default)  
Disable  
Onboard Video  
Enable (default)  
Disable  
Enable  
Onboard NIC1  
NIC1 PXE  
Disable (default)  
Enable (default)  
Disable  
Onboard NIC2  
NIC2 PXE  
Enable  
Disable (default)  
Enable (default)  
Disable  
Enable (default)  
Disable  
Enable (default)  
Disable  
Enable (default)  
Disable  
Slot 1 Option ROM  
Slot 2 Option ROM  
Slot 3 Option ROM  
Slot 4 Option ROM  
No such item in SKU3,4  
No such item in SKU3,4  
No such item in SKU3,4  
No such item in SKU3,4  
59  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.5  
BOOT menu  
To access this menu, select Exit from the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
> CD/DVD Drives  
The menu represented by Table 32 is for Boot features.  
Table 32. Boot Features  
Feature  
Options  
Description  
>Boot Settings  
Configuration  
Submenu  
Configuration Settings during boot.  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
Submenu  
Submenu  
Submenu  
Boot device priority sequence.  
Boot device priority sequence from available driver.  
Boot device priority sequence from available removable  
driver.  
>CD/DVD Drives  
Submenu  
Boot device priority sequence from available ATAPI CDROM  
driver.  
4.8.5.1  
Boot Settings Configuration Submenu  
To access this menu, select Boot on the menu bar, then Boot Settings Configuration  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
>CD/DVD Drives  
The submenu represented by Table 33 is for Boot Settings Configuration.  
Table 33. Boot Settings Configuration Submenu  
Feature  
Options  
Description  
Quick Boot  
Enable (default)  
Disable  
Allows BIOS to skip certain tests while booting. This will  
decrease the time needed to boot the system.  
60  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Feature  
Options  
Description  
Quiet Boot  
Enable (default)  
Disable  
Force BIOS (default)  
Keep Current  
Off  
Displays OEM Logo instead of POST messages.  
Set display mode for Option ROM.  
Select Power-on state for Numlock.  
Select support for PS/2 Mouse.  
AddOn ROM Display  
Mode  
Bootup Num-Lock  
On (default)  
Enable  
PS/2 Mouse Support  
Disable  
Auto (default)  
Enable (default)  
Disable  
POST Error Pause  
If enabled, the system will wait for user intervention on  
critical POST errors. If disabled, the system will boot  
with no intervention, if possible.  
Hit <F2> Message  
Display  
Enable (default)  
Disable  
Displays "Press <F2> to run Setup" in POST.  
1 MB  
1 KB  
Every Location  
Disabled (default)  
Extended Memory  
Test  
Extended Memory Test Tests extended memory  
- Once per KB, or  
- Once per MB, or  
- Every location or  
- Disable  
Enabling this option disables Quiet Boot.  
Enable  
Disable (default)  
Scan User Flash Area  
Allows BIOS to scan the Flash ROM for user binaries.  
4.8.5.2  
Boot Device Priority Submenu  
To access this menu, select Boot on the menu bar, then Boot Device Priority Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
> CD/DVD Drives  
The submenu represented by Table 34 is for Boot Device Priority.  
Table 34. Boot Device Priority Submenu  
Feature  
Options  
Varies  
Description  
1st Boot Device  
Number of entries will vary based on system  
configuration.  
nth Boot Device  
Varies  
Number of entries will vary based on system  
configuration.  
61  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.5.3  
Hard Disk Drives submenu  
To access this menu, select Boot on the menu bar, then Hard Disk Drives.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
>CD/DVD Drives  
The submenu represented by Table 35 is for Boot Device Priority.  
Table 35. Boot Disk Drives Submenu  
Feature  
Options  
Option  
Description  
Specifies the boot sequence from the available devices  
1st~15th Boot Device  
4.8.5.4  
Removable Drives Submenu  
To access this menu, select Boot on the menu bar, then Removable Drives.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
>CD/DVD Drives  
The menu represented in Table 36 is for Removable Drives.  
Table 36. Removable Drives Submenu  
Feature  
Options  
Varies  
Varies  
Description  
Varies based on system configuration.  
Varies based on system configuration.  
1st Device  
nth Device  
62  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.5.5  
CD/DVD Drives Submenu  
To access this menu, select Boot on the menu bar, then CD/DVD Drives.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>Boot Settings Configuration  
>Boot Device Priority  
>Hard Disk Drives  
>Removable Drives  
>CD/DVD Drives  
The submenu represented in Table 37 is for setting the CD/DVD Drives.  
Table 37. CD/DVD Drives Submenu  
Feature  
Options  
Varies  
Varies  
Description  
Varies based on system configuration.  
Varies based on system configuration.  
1st Device  
nth Device  
4.8.6  
Security Menu  
To access this menu, select Security from the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
The menu represented in Table 38 is for Security features.  
Table 38. Security Menu  
Feature  
Options  
Description  
No options  
Change Supervisor  
Set password to null to clear.  
Password  
No options  
Change User  
Password  
Set password to null to clear.  
no options  
Enable  
Disable (default)  
Enable  
Clear User Password  
Immediately clears the User Password.  
Enable/Disable Boot Sector Virus Protection.  
Boot Sector Virus  
Protection  
Diskette Write  
Protect  
Disables/Enables diskette driver write protection.  
Disable  
(default)Enable  
Enable  
Disable (default)  
NMI Control  
Enable/Disable NMI control through the National  
Semiconductor PC87431 Integrated Management  
Controller for the front panel NMI button.  
63  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.8.7  
Server Menu  
To access this menu, select Server from the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>> System Management  
>> Serial Console Features  
>> Event Log configuration  
Assert NMI on PERR  
Assert NMI on SERR  
Power Link  
Platform Event Filtering  
FRB-2 Policy  
Late POST Timeout  
Hard Disk OS Boot Timeout  
PXE OS Boot Timeout  
FRB-4 Policy  
The menu represented in Table 39 is for Server features.  
Table 39. Server Menu  
Feature  
Options  
Description  
No options  
No options  
System Management  
Selects submenu.  
Selects submenu.  
Serial Console  
Features  
No options  
Event Log  
Selects submenu.  
configuration  
Disabled  
Enabled (default)  
Disabled  
Enabled (default)  
Stays Off  
Power On  
Assert NMI on PERR  
Assert NMI on SERR  
Power Link  
If enabled, NMI is generated. SERR option needs to be  
enabled to activate this option.  
If enabled, NMI is generated on SERR and logged.  
Determines the mode of operation if a power loss occurs. If  
Stays Off is selected, the system remains off once power is  
restored. If Power On is selected, the system will boot after  
power is restored. When available, Last State restores the  
system to state it was in before power failed.  
Disabled  
Enabled  
Platform Event  
Filtering  
Retry on Next Boot  
FRB-2 Policy  
Controls whether or not the FRB2 Timer will be disabled.  
(default)  
Disable FRB2  
Timer  
64  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Disable (default)  
5 minutes  
Late POST Timeout  
Controls the time limit allowed for add-in card detection.  
The system is reset on timeout.  
10 minutes  
15 minutes  
20 minutes  
Disable (default)  
5 minutes  
10 minutes  
15 minutes  
20 minutes  
Disable (default)  
5 minutes  
10 minutes  
15 minutes  
20 minutes  
Stay On (default)  
Reset  
Hard Disk OS Boot  
Timeout  
Controls the time limit allowed for booting an OS from a  
hard disk drive. The action taken on timeout is determined  
by the Fault Resilient Boot Timer policy setting.  
PXE OS Boot  
Timeout  
This controls the time limit allowed for booting an OS using  
PXE boot. The action taken on timeout is determined by  
the Fault Resilient Boot Timer policy setting.  
FRB-4 Policy  
Controls the policy upon timeout. If Stay On is selected, no  
overt action will be taken. If Reset is selected, the system  
will be forced to reset. If Power Off is selected, the system  
will be forced to power off.  
Power Off  
4.8.7.1  
System Management Submenu  
To access this menu, select Server on the menu bar, then System Management.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>> System management  
>> Serial Console Features  
>> Event Log configuration  
Assert NMI on PERR  
Assert NMI on SERR  
AC Link  
FRB-2 Policy  
Late POST Timeout  
Hard Disk OS Boot Timeout  
PXE OS Boot Timeout  
FRB-4 Policy  
65  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The submenu represented in Table 40 is for setting the System Management.  
Table 40. System Managment Submenu  
Feature  
Board Part Number:  
Options  
No options  
No options  
Description  
Varies  
Varies  
Board Serial  
Number:  
No options  
No options  
No options  
No options  
System Part  
Number:  
Varies  
Varies  
Varies  
Varies  
System Serial  
Number:  
Chassis Part  
Number:  
Chassis Serial  
Number:  
No options  
No options  
No options  
Version:  
BMC Device ID  
BIOS ID string.  
Varies  
Varies  
BMC Firmware  
Revision:  
No options  
No options  
BMC Revision:  
SDR Revision:  
Varies  
Varies  
4.8.7.2  
Serial Console Features Submenu  
To access this menu, select Server on the menu bar, then Serial Console Features  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>> System management  
>> Serial Console Features  
>> Event Log configuration  
Assert NMI on PERR  
Assert NMI on SERR  
Power Link  
Platform Event Filtering  
FRB-2 Policy  
Late POST Timeout  
Hard Disk OS Boot Timeout  
PXE OS Boot Timeout  
FRB-4 Policy  
66  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The submenu represented in Table 41 is for setting the Serial Console Features.  
Table 41. Serial Console Features Submenu  
Feature  
Options  
Description  
Disabled (default)  
Serial 1 (DB-9)  
Serial 2 (RJ-45)  
BIOS Redirection  
Port  
If enabled, BIOS uses the specified serial port to redirect  
the console to a remote ANSI terminal. Enabling this  
option disables Quiet Boot.  
Keys used in console:  
ESC +’0’ :F10  
ESC +’1’..’9’ :F1..F9 +’0’ ESC +’{’ :Refresh Screen  
9600  
Baud Rate  
19.2K (default)  
38.4K  
57.6K  
115.2K  
No Flow Control  
CTS/RTS (default)  
XON/XOFF  
CTS/RTS + CD  
Flow Control  
If enabled, it will use the Flow control selected.  
CTS/RTS = Hardware  
XON/XOFF = Software  
CTS/RTS + CD = Hardware + Carrier Detect for Modem  
use.  
PC-ANSI  
VT100+ (default)  
VT-UTF8  
Terminal Type  
VT100+ selection only works for English as the select  
language. VT-UTF8 uses Unicode. PC-ANSI is the  
standard PC-type terminal.  
4.8.7.3  
Event Log Configuration Submenu  
To access this menu, select Server on the menu bar, then Event Log Configuration.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
>> System management  
>> Serial Console Features  
>> Event Log Configuration  
Assert NMI on PERR  
Assert NMI on SERR  
Power Link  
Platform Event Filtering  
FRB-2 Policy  
Late POST Timeout  
Hard Disk OS Boot Timeout  
PXE OS Boot Timeout  
FRB-4 Policy  
67  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
The submenu represented in Table 42 is for setting the Event Log Configuration.  
Table 42. Event Log Configuration Submenu  
Feature  
Options  
Description  
Disabled (default)  
Enabled  
Clear All Event Logs  
Setting this to Enabled will clear the DMI event log after  
system booting.  
Disabled  
Event Logging  
Select Enabled to allow logging of events.  
Enabled (default)  
Disabled  
Enabled (default)  
Critical Event  
Logging  
If enabled, BIOS will detect and log events for system  
critical errors. Critical errors are fatal to system operation.  
These errors include PERR, SERR, and ECC.  
ECC Event Logging  
PCI Error logging  
Disabled  
Enabled (default)  
Disabled  
Enabled (default)  
4.8.8  
Exit Menu  
To access this menu, select Exit from the menu bar at the top of the screen.  
Main  
Advanced  
Boot  
Security  
Server  
Exit  
The menu represented in Table 43 is for exiting the BIOS Setup program, saving changes, and  
loading and saving defaults.  
Table 43. Exit Menu  
Feature  
Description  
Save Changes and Exit  
Exits and saves the changes in CMOS SRAM.  
F10 key can be used for this operation.  
Exits without saving any changes made in the BIOS Setup program.  
ESC key can be used for this operation.  
Discards changes without exiting Setup. The option values present when the server  
was turned on are used.  
Discard Changes and Exit  
Discard Changes  
F7 key can be used for this operation  
Load Optimal Defaults  
Load Failsafe Defaults  
Load Optimal Default values for all the setup questions.  
F9 key can be used for this operation.  
Load Failsafe Default values for all the setup questions.  
F8 key can be used for this operation.  
Load Custom Defaults  
Save Custom Defaults  
Load Custom Defaults  
Save Custom Defaults  
68  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.9 Operating System Boot, Sleep and Wake  
4.9.1  
Microsoft* Windows* Compatibility  
Intel Corporation and Microsoft Corporation co-author design guides for system designers using  
Intel processors and Microsoft* operating systems. These documents are updated yearly to  
address new requirements and current trends.  
PC200x specifications are intended for systems that are designed to work with Windows 2000  
and Windows XP class operating systems. The Hardware Design Guide (HDG) for the Windows  
XP platform is intended for systems that are designed to work with Windows XP class operating  
systems. Each specification classifies the systems further and has requirements based on the  
intended usage for that system. For example, a server system that will be used in small  
home/office environments has different requirements than the one used for enterprise  
applications.  
The server board SE7210TP1-E supports HDG3.0.  
4.9.2  
Advanced Configuration and Power Interface (ACPI)  
ACPI gives the operating system direct control over the power management and Plug and Play  
functions of a server. The use of ACPI with the Intel Server Board SE7210TP1-E requires an  
operating system that provides full ACPI support. ACPI features include:  
Plug and Play (including bus and device enumeration)  
Power management control of individual devices, add-in boards (some add-in boards  
may require an ACPI-aware driver), video displays, and hard disk drives  
Methods for achieving less than 15-watt system operation in the standby or  
sleeping state  
A Soft-off feature that enables the operating system to power-off the server  
Support for multiple wake-up events.  
Support for a front panel power and sleep mode switch  
4.9.3  
Sleep and Wake Functionality  
The BIOS supports up to four front panel buttons: the power button, the reset button, the sleep  
button, and the NMI button. The NMI button is a recessed button and may not be accessible on  
all front panel designs.  
The power button is a request that is forwarded by the National Semiconductor PC87431  
integrated management controller to the ACPI power state machines in the chipset. It is  
monitored by the National Semiconductor PC87431 integrated management controller and does  
not directly control power on the power supply.  
The BIOS supports a front panel NMI button. The NMI button is a request that causes the  
National Semiconductor PC87431 integrated management controller to generate an NMI (non-  
maskable interrupt). The operating system is responsible for handling the NMI core dump.  
The power button behaves differently depending on whether the operating system supports  
ACPI. If the operating system supports ACPI the power button can be configured as a sleep  
69  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
button. The operating system causes the system to transition to the appropriate system state  
depending on the user settings.  
4.9.3.1  
On to Off (OS-Present) or OS to Sleep  
If an operating system is loaded, the power button switch generates a request via the system  
control interrupt (SCI) to the operating system to shutdown the system. The operating system  
retains control of the system and operating system policy determines if the system transitions  
into S4/S1 or shuts down.  
4.9.3.2  
Sleep to On (ACPI)  
If an operating system is loaded, the power button or Wake on LAN (WOL) can generate a wake  
event to the ACPI chipset and a request (via SCI). If system wakes up from S4/S5, the BIOS  
POST is completed and then control is given to operating system to wake up the system. If  
wakeup is from S1, the operating system will wake up the system.  
4.9.3.3  
System Sleep States  
The platform supports the following ACPI System Sleep States:  
ACPI S0 (working) state  
ACPI S1 (sleep) state  
ACPI S4 (suspend to disk) state  
ACPI S5 (soft-off) state  
Table 44: Supported Wake Events  
Wake Event  
Supported via ACPI (by sleep state)  
Always wakes system.  
Supported Via  
Legacy Wake  
Always wakes  
system  
Power Button  
PME from PCI cards  
RTC Alarm  
Mouse  
Keyboard  
USB  
Wakes from S1 and S4.  
Wakes from S1. Always wakes the system up from S4.  
Wakes from S1.  
Wakes from S1.  
Wakes from S1.  
Yes  
No  
No  
No  
No  
70  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Table 45 lists the system states based on how long the power switch is pressed, depending on  
how ACPI is configured with an ACPI-aware operating system.  
Table 45. Effects of Pressing the Power Switch  
…and the power switch is  
If the system is in this state…  
pressed for  
…the system enters this state  
Power-on  
Off  
Less than four seconds  
(ACPI S5 – Soft off)  
(ACPI S0 – working state)  
On  
Less than four seconds  
More than four seconds  
Soft-off/Standby  
(ACPI S0 – working state)  
(ACPI S1 or S3 – sleeping state)  
On  
Fail safe power-off  
(ACPI S0 – working state)  
(ACPI S5 – Soft off)  
4.9.3.4  
System States and Power States  
Under ACPI, the operating system directs all system and device power state transitions. The  
operating system puts devices in and out of low-power states based on user preferences and  
knowledge of how devices are being used by applications. Devices that are not being used can  
be turned off. The operating system uses information from applications and user settings to put  
the system as a whole into a low-power state.  
Table 46 lists the power states supported by the server board SE7210TP1-E along with the  
associated system power targets. See the ACPI specification for a complete description of the  
various system and power states.  
Table 46. Power States and Targeted System Power  
Processor  
States  
Targeted System  
Power (Note 1)  
Global States  
G0 – working  
state  
Sleeping States  
Device States  
S0 – working  
C0 – working  
D0 – working state. Full power > 30 W  
G2/G5  
S5 – Soft off.  
Context not saved.  
Cold boot is  
No power  
No power  
D3 – no power  
except for wake-up  
logic.  
Power < 5 W (Note 2)  
required.  
G3 – mechanical No power to the  
D3 – no power for  
wake-up logic,  
No power to the system.  
Service can be performed  
safely.  
off  
system.  
except when  
AC power is  
provided by battery  
or external source.  
disconnected  
from the server.  
Notes:  
1. Total system power is dependent on the system configuration, including add-in boards and peripherals powered  
by the system chassis’ power supply.  
2. Dependent on the standby power consumption of wake-up devices used in the system.  
71  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
4.10 Security  
The BIOS provides a number of security features. This section describes the security features  
and operating model.  
The BIOS uses passwords to prevent unauthorized tampering with the system. Once secure  
mode is entered, access to the system is allowed only after the correct password(s) has been  
entered. Both User and Administrator passwords are supported by the BIOS. Each password  
can be independently set or cleared during system configuration using a setup. The maximum  
length of the password is seven characters. The password cannot have characters other than  
alphanumeric (a-z, A-Z, 0-9).  
Once set, a password can be cleared by changing it to a null string. Entering the User password  
will allow the user to modify the time, date, language, user password. Other setup fields can be  
modified only if the Administrator password is entered. If only one password is set, this  
password is required to enter Setup.  
Administrator has control over all fields in the setup including the ability to clear user password.  
If the user enters three wrong passwords in a row during the boot sequence, the system will be  
placed into a halt state. This feature makes it difficult to break the password by “trial and error”  
method.  
4.10.1  
Notes:  
Administrator/User Passwords and F2 Setup Usage Model  
Visible=option string is active and changeable  
Hidden=option string is inactive and not visible  
Shaded=option string is gray-out and view-only  
There are four possible password scenarios:  
Scenario #1  
Admin/Supervisor Password Not Installed  
User Password  
Login Type: N/A  
Not Installed  
Set Admin/Supervisor Password (visible)  
Set User Password (visible)  
User Access Level [Full]** (shaded)  
Clear User Password (hidden)  
**: User Access Level option will be Full and Shaded as long as the admin/supervisor password  
is not installed.  
72  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Scenario #2  
Admin/Supervisor Password Installed  
User Password  
Installed  
Login Type: Admin/Supervisor  
Set Admin/Supervisor Password (visible)  
Set User Password (visible)  
User Access Level [Full] (visible)  
Clear User Password (visible)  
Login Type: User  
Set Admin/Supervisor Password (hidden)  
Set User Password (visible)  
User Access Level [Full] (Shaded)  
Clear User Password (hidden)  
Scenario #3  
Admin/Supervisor Password - Not Installed  
User Password  
- Installed  
Login Type: User  
Set Admin/Supervisor Password (visible)  
Set User Password (visible)  
User Access Level [Full]** (shaded)  
Clear User Password (hidden)  
Login Type: <Enter>  
No Access  
**: User Access Level option will be Full and Shaded as long as the admin/supervisor password  
is not installed.  
73  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
System BIOS  
Scenario #4  
Admin/Supervisor Password Installed  
User Password  
Not Installed  
Login Type: Supervisor  
Set Admin/Supervisor Password (visible)  
Set User Password (visible)  
User Access Level [Full] (visible)  
Clear User Password (hidden)  
Login Type: <Enter>  
No Access  
4.10.2  
Password Clear Jumper  
If the user or administrator password(s) is lost or forgotten, both passwords may be cleared by  
moving the password clear jumper to the clear position. The BIOS determines if the password  
clear jumper is in the clear position during BIOS POST and clears any passwords if required.  
The password clear jumper must be restored to its original position before a new password(s)  
can be set.  
74  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5. Platform Management Architecture  
This chapter will provide an overview of the integrated platform management architecture and  
details of the features and functionality of the Essentials management model.  
5.1 Essential Management Features and Functionality  
5.1.1  
Overview of National* Semiconductor PC87431 Integrated  
Management Controller  
The National Semiconductor PC87431 integrated management controller is an Application  
Specific Integrated Circuit (ASIC) with a Reduced Instruction Set Computer (RISC)-based  
processor and many peripheral devices embedded into it. The National Semiconductor  
PC87431 integrated management controller contains the logic needed for executing the  
firmware, controlling the system, monitoring the sensors, and communicating with other systems  
and devices via various external interfaces.  
The following figure is a block diagram of the National Semiconductor PC87431 integrated  
management controller as it is used in a server management system. The external interface  
blocks to the National Semiconductor PC87431 integrated management controller are the  
discrete hardware peripheral device interface modules.  
General  
purpose Output  
Flash  
Memory  
Bus Interface  
Unit  
GPIO Pins  
and Digital  
Input  
Front Panel  
and Power Stat  
Signal  
Interrupt Pins  
SIO  
SMBus  
SMBus  
one SMBus  
Interfaces  
Private I2C  
Buses  
Sensor devices  
LAN on  
Motherboard  
(LOM)  
SMBus  
Processor  
Interface  
mBMC ASIC  
Figure 10: National Semiconductor PC87431 integrated management controller in a Server  
Management System  
75  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.1.2  
National Semiconductor PC87431 integrated management controller  
Self-test  
The National Semiconductor PC87431 integrated management controller performs various tests  
as part of its initialization. If a failure is determined, the National Semiconductor PC87431  
integrated management controller stores the error internally. A failure may be caused by a  
corrupt National Semiconductor PC87431 integrated management controller FRU, SDR, or  
SEL. Two commands may be used to retrieve the detected errors. The IPMI 1.5 Get Self Test  
Results command can be used to return the first error detected.  
Executing the Get Self Test Results command causes the National Semiconductor PC87431  
integrated management controller self-test to be run. It is strongly recommended to reset the  
National Semiconductor PC87431 integrated management controller via the Cold Reset  
command afterwards.  
5.1.3  
SMBus Interfaces  
The National Semiconductor PC87431 integrated management controller incorporates one  
master/slave and two master-only SMBus interfaces. The National Semiconductor PC87431  
integrated management controller interfaces with the host through a slave SMBus interface. It  
interfaces with the LAN On Motherboard (LOM) and peripherals through two independent  
master bus interfaces.  
5.1.4  
External Interface to National Semiconductor PC87431 integrated  
management controller  
Figure 11 shows the data/control flow to and within the functional modules of the National  
Semiconductor PC87431 integrated management controller. External interfaces from the host  
system, LOM, and peripherals, interact with the National Semiconductor PC87431 integrated  
management controller through the corresponding interface modules as shown.  
The National Semiconductor PC87431 integrated management controller communicates with  
the internal modules using its private SMBus. External devices and sensors interact with the  
National Semiconductor PC87431 integrated management controller using the peripheral  
SMBus through SIO. LOM communicates through the LOM SMBus. GPIO pins are available  
and can be configured for general purpose output or digital input events. Dedicated LED lines  
are available for LED/color control.  
Also built into the National Semiconductor PC87431 integrated management controller are the  
control functions for both the power supply and front panel.  
76  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
PCI  
SMBus  
Sensor  
Devices  
SM Bus  
Front Panel  
Figure 11: External Interfaces to National Semiconductor PC87431 integrated management  
controller  
5.1.4.1  
Private Management I2C Buses  
The National Semiconductor PC87431 integrated management controller implements a single  
private management bus. The National Semiconductor PC87431 integrated management  
controller is the sole master on this bus. External agents must use the National Semiconductor  
PC87431 integrated management controller Master Write/Read I2C command if they require  
direct communication with a device on this bus. In addition, the National Semiconductor  
PC87431 integrated management controller provides a Reserve Device command that gives an  
external agent exclusive access to a specific device for a selectable time.  
5.1.5  
Messaging Interfaces  
This section describes the supported National Semiconductor PC87431 integrated management  
controller communication interfaces:  
Host SMS interface via SMBus interface  
LAN interface using the LAN On Motherboard SMBus  
77  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.1.5.1  
Channel Management  
The National Semiconductor PC87431 integrated management controller supports two  
channels:  
System interface  
802.3 LAN  
Table 47: Supported Channel Assigments  
Channel Id  
Media type  
Supports  
Interface  
Sessions  
1
2
802.3 LAN  
System Interface  
IPMB 1.0  
Multi sessions  
IPMI-SMBus Session-less  
5.1.5.2  
User Model  
The National Semiconductor PC87431 integrated management controller supports one  
anonymous user (null user name) with a settable password. The IPMI command to set the  
password is not supported.  
5.1.5.3  
Request/Response Protocol  
All of the protocols used in the host interface and the LOM interface are Request/Response  
protocols. A Request Message is issued to an intelligent device, to which the device responds  
with a separate Response Message.  
5.1.5.4  
Host to National Semiconductor PC87431 integrated management  
controller Communication Interface  
The host communicates with the National Semiconductor PC87431 integrated management  
controller via the System Management Bus (SMBus). The interface consists of three signals:  
SMBus clock signal (SCLH)  
SMBus data signal (SDAH)  
Optional SMBus alert signal (SMBAH). The signal notifies the host that the PC87431x  
has data to provide.  
When the system main power is off (PWRGD signal is low), the host interface signals are in  
TRI-STATE to perform passive bus isolation between the National Semiconductor PC87431  
integrated management controller SCLH, SDAH and SMBAH signals and the SMBus controller  
signals. The passive bus isolation can be disabled by host SMBus isolation control to support  
various system designs.  
78  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
The National Semiconductor PC87431 integrated management controller is a slave device on  
the bus. The host interface is designed to support polled operations. Host applications can  
optionally handle an SMBus alert interrupt if the National Semiconductor PC87431 integrated  
management controller is unable to respond immediately to a host request. In this case, “Not  
Ready” is indicated in one of two ways:  
The host interface bandwidth is limited by the bus clock and National Semiconductor  
PC87431 integrated management controller latency. To meet the device latency, the  
National Semiconductor PC87431 integrated management controller slows down the  
bus periodically by extending the SMBus clock low interval (SCLH).  
If the National Semiconductor PC87431 integrated management controller is in the  
middle of a LAN or peripheral device communication, or if a response to the host request  
is not yet ready, the National Semiconductor PC87431 integrated management  
controller does not acknowledge the device address (“NACK”). This forces the host  
software to stop and restart the session.  
For more information on read-write through SMBus refer the System Management Bus (SMBus)  
Specification 2.0.  
5.1.5.5  
LAN Interface  
The baseboard supports one DPC LAN interface via a UDP port 26Fh. The National  
Semiconductor PC87431 integrated management controller supports a maximum of one  
simultaneous session across all authenticated channels. The baseboard implements gratuitous  
ARP support according to the IPMI 1.5 Specification.  
The IPMI Specification v1.5 defines how IPMI messages, encapsulated in RMCP packet format,  
can be sent to and from the National Semiconductor PC87431 integrated management  
controller. This capability allows a remote console application to access the National  
Semiconductor PC87431 integrated management controller and perform the following  
operations:  
Chassis Control, e.g., get chassis status, reset chassis, power-up chassis, power-down  
chassis  
Get system sensor status  
Get and Set system boot options  
Get Field Replaceable Unit (FRU) information  
Get System Event Log (SEL) entries  
Get Sensor Data Records (SDR)  
Set Platform Event Filtering (PEF)  
Set LAN configurations  
In addition, the National Semiconductor PC87431 integrated management controller supports  
LAN alerting in the form of SNMP traps that conform to the IPMI Platform Event Trap (PET)  
format.  
79  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Table 48: LAN Channel Capacity  
LAN CHANNEL Capability  
Options  
Number of Sessions  
Number of Users  
1
1
User  
Name NULL (anonymous)  
User Password  
Configurable  
Privilege Levels  
User, Operator, Administrator  
Authentication Types  
Number of LAN Alert Destinations  
Address Resolution Protocol (ARP)  
MD5  
1
Gratuitous ARP  
5.1.6  
Direct Platform Control (IPMI over LAN)  
Direct Platform Control provides a mechanism for delivering IPMI Messages directly to the  
management controllers via a LAN connection. The NICs and the management controllers  
remain active on standby power, enabling the IPMI Messaging when the system is powered up,  
powered down, and in a system sleep state. This allows a remote console application to be able  
to access the management controller capabilities, including:  
Power on/off and reset control with the ability to set BIOS boot flags  
FRU, SDR, and SEL access  
National Semiconductor PC87431 integrated management controller configuration  
access  
Ability to transfer IPMI messages between the LAN interface and other interfaces, such  
as the System Interface, IPMB, and PCI SMBus. This capability enables messages to be  
delivered to system management software, and provides the ability to access sensors  
and FRU information on other management controllers.  
IPMI Messages are encapsulated in a packet format called RMCP (Remote Management  
Control Protocol). The Distributed Management Task Force (DMTF) has defined RMCP for  
supporting pre-OS and OS-absent management. RMCP is a simple request-response protocol  
that can be delivered using UDP datagrams. IPMI-over-LAN uses version 1 of the RMCP  
protocol and packet format.  
UDP port 26Fh is a ‘well known’ port address that is specified to carry RMCP (Remote  
Management Control Protocol) formatted UDP datagrams. The on-board Intel network interface  
controllers contain circuitry that enables detecting and capturing RMCP packets that are  
received on Port 26Fh and making them available to the management controller via a ‘side-  
band’ interface that is separate from the PCI interface to the NIC. Similarly, the management  
controller can use the side-band interface to send packets from Port 26Fh, as shown in the  
following figure.  
80  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
LAN  
RMCP  
Port  
In-band  
Traffic  
26Fh  
NIC #1  
mBMC  
side-band connection  
PCI  
System Bus  
Figure 12 - IPMI-over-LAN  
RMCP includes a field that indicates the class of messages that can be embedded in an RMCP  
message packet. For RMCP version 1.0, the defined classes are IPMI, ASF, and OEM. IPMI-  
over-LAN uses the IPMI class to transfer IPMI Messages encapsulated in RMCP packets.  
Intelligent Platform Management Interface v1.5 Specification specifies the packet formats and  
commands used to perform IPMI Messaging on LAN via RMCP.  
The management controller transmits to other port addresses as needed. For example, LAN  
Alerts, which are sent as SNMP Traps, can be transmitted to the SNMP Trap ‘well known’ port  
address, 162 (0A2h).  
5.1.6.1  
LAN Channel Specifications  
The following table presents the minimum support that will be provided. Note that system  
management software and utilities may not use all the available management controller options  
and capabilities. For detailed technical information on the operation of the LAN channel  
operation and LAN Alerting, refer to Intelligent Platform Management Interface v1.5  
Specification.  
Table 49: LAN Channel Specifications  
Configuration Capability  
Options  
Description/Notes  
This option determines when the National  
Semiconductor PC87431 integrated management  
controller can be accessed via IPMI Messaging over  
LAN.  
always-active,  
disabled  
Channel Access Modes  
The number of simultaneous sessions that can be  
supported is shared across the LAN and serial/modem  
channels.  
1 (Essentials)  
1 (Essentials)  
No (Essentials)  
Number of Sessions  
Number of Users  
User information is a resource that is shared across the  
LAN and serial/modem channels.  
User information is a resource that is shared across the  
LAN and serial/modem channels.  
Configurable User Names  
Configurable User  
Passwords  
Yes  
81  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Description/Notes  
Configuration Capability  
Options  
User, Operator,  
Administrator  
Privilege Levels  
IPMI Message  
Authentication Type  
Support  
MD5  
Number of LAN Alert  
1 (Essentials)  
destinations  
PET Acknowledge support Yes  
Gratuitous ARP Support Yes  
5.1.6.2  
LAN Drivers and Setup  
The IPMI-over-LAN feature must be used with the appropriate Intel NIC Driver, and the NIC  
correctly configured in order for DPC LAN operation to occur transparently to the operating  
system and network applications. If an incorrect driver or NIC configuration is used, it is possible  
to get driver timeouts when the IPMI-over-LAN feature is enabled.  
5.1.6.3  
BIOS Boot Flags  
A remote console application can use the IPMI Set System Boot Options command to configure  
a set of BIOS boot flags and boot initiator info parameters that are held by the management  
controller. These parameters include information that identifies the party that initiated the boot,  
plus flags and other information that can be used to direct the way booting proceeds after a  
system reset or power-up. For example, whether the system should boot normally, boot using  
PXE, boot to a diagnostic partition, etc.  
5.1.6.4  
Boot Flags and LAN Console Redirection  
The system BIOS includes a LAN Console Redirection capability. This capability can only be  
directed to one IP Address at a time. Thus, the boot flags and boot initiator information are also  
used to tell the BIOS where to send LAN Console Redirection.  
5.1.7  
Wake On LAN / Power On LAN and Magic Packet Support  
The baseboard supports Wake On LAN / Power On LAN capability using the on-board network  
interface chips or an add-in network interface card. An add-in network card can deliver the wake  
signal to the baseboard via the PME signal on the PCI bus. The actual support for Magic Packet  
and/or packet filtering for Wake On LAN / Power On LAN is provided by the NIC. The  
baseboard handles the corresponding wake signal.  
5.1.7.1  
Wake On LAN in S4/S5  
A configuration option is provided that allows the on-board NICs to be enabled to wake the  
system in an S4/S5 state, even if the operating system disabled Wake-On-LAN when it powered  
down the system. This provides an option for users who want to use standard, but non-secure,  
WOL capability for operations such as after-hours maintenance. Note that the DPC LAN  
capability provides a secure system power-up, plus the ability to provide BIOS boot options, by  
sending authenticated IPMI messages directly to the National Semiconductor PC87431  
integrated management controller via the on-board NICs.  
82  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.1.8  
Watchdog Timer  
The National Semiconductor PC87431 integrated management controller implements an IPMI  
1.5-compatible watchdog timer. See the IPMI specification for details. SMI and NMI pre-timeout  
actions are supported, as are hard reset, power down, and power cycle timeout actions.  
5.1.9  
System Event Log (SEL)  
The National Semiconductor PC87431 integrated management controller implements the logical  
System Event Log device as specified in the Intelligent Platform Management Interface  
Specification, Version 1.5. The SEL is accessible via all communication transports. In this way,  
the SEL information can be accessed while the system is down by means of out-of-band  
interfaces. The maximum SEL size that is supported by National Semiconductor PC87431  
integrated management controller is 92 entries.  
Supported commands are:  
Get SEL Info  
Reserve SEL  
Get SEL Entry  
Add SEL Entry  
Clear SEL  
Get SEL Time  
Set SEL Time  
5.1.9.1  
Timestamp Clock  
The National Semiconductor PC87431 integrated management controller maintains a four-byte  
internal timestamp clock used by the SEL and SDR subsystems. This clock is incremented once  
per second. It is read using the Get SEL Time command and set using the Set SEL Time  
command. The Get SDR Time command can also be used to read the timestamp clock. These  
commands are specified in the Intelligent Platform Management Interface Specification, Version  
1.5.  
After a National Semiconductor PC87431 integrated management controller reset, the National  
Semiconductor PC87431 integrated management controller sets the initial value of the  
timestamp clock to 0x00000000. It is incremented once per second after that. A SEL event  
containing a timestamp from 0x00000000 to 0x140000000 has a timestamp value that is relative  
to National Semiconductor PC87431 integrated management controller initialization.  
The BIOS provides the time to the National Semiconductor PC87431 integrated management  
controller during POST. During POST, the BIOS tells the National Semiconductor PC87431  
integrated management controller the current RTC time via the Set SEL Time command. The  
National Semiconductor PC87431 integrated management controller maintains this time,  
incrementing it once per second, until the National Semiconductor PC87431 integrated  
management controller is reset or the time is changed via another Set SEL Time command.  
If the RTC changes during system operation, system management software synchronizes the  
National Semiconductor PC87431 integrated management controller time with the system time.  
83  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.1.10  
Sensor Data Record (SDR) Repository  
The National Semiconductor PC87431 integrated management controller includes built-in  
Sensor Data Records that provide platform management capabilities (sensor types, locations,  
event generation and access information). SDR Repositories are kept in the non-volatile storage  
area (flash) of the National Semiconductor PC87431 integrated management controller. The  
SDR Repository is accessible via all communication transports. This way, out-of-band interfaces  
can access the SDR Repository information if the system is down.  
The National Semiconductor PC87431 integrated management controller supports 2176 bytes  
of storage for SDR records. The SDR defines the type of sensor, thresholds, hysteresis values  
and event configuration. The National Semiconductor PC87431 integrated management  
controller supports up to six threshold values for threshold-based full sensor records, and up to 15  
events for non threshold-based full and compact sensor records. It also supports both low-going and  
high-going sensor devices.  
5.1.10.1  
Initialization Agent  
The National Semiconductor PC87431 integrated management controller implements the  
internal sensor initialization agent functionality specified in the Intelligent Platform Management  
Interface Specification, Version 1.5. When the National Semiconductor PC87431 integrated  
management controller initializes, or when the system boots, the initialization agent scans the  
SDR repository and configures the sensors referenced by the SDRs. This includes setting  
sensor thresholds, enabling/disabling sensor event message scanning, and enabling/disabling  
sensor event messages.  
5.1.11  
Event Message Reception  
The National Semiconductor PC87431 integrated management controller supports externally  
(e.g., BIOS) generated events via the Platform Event Message command. Events received via  
this command will be logged to the SEL and processed by PEF.  
5.1.12  
Event Filtering and Alerting  
The National Semiconductor PC87431 integrated management controller implements the following  
IPMI 1.5 alerting features:  
PEF  
Alert over LAN  
84  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.1.12.1  
Platform Event Filtering (PEF)  
The National Semiconductor PC87431 integrated management controller monitors platform  
health and logs failure events into the SEL. The Platform Event Filtering feature provides a  
configurable mechanism to allow events to trigger alert actions. PEF provides a flexible, general  
mechanism that enables the National Semiconductor PC87431 integrated management  
controller to perform selectable actions triggered by a configurable set of platform events. The  
National Semiconductor PC87431 integrated management controller supports the following  
IPMI PEF actions:  
Power-down  
Soft shut-down  
Power cycle  
Reset  
Diagnostic Interrupt  
Alert  
In addition, the National Semiconductor PC87431 integrated management controller supports  
the following OEM actions:  
Fault LED action  
Identification LED action  
Device feedback  
The power-down, soft shut-down, power cycle and reset actions can be delayed by a specified  
number of 100ms.  
The National Semiconductor PC87431 integrated management controller maintains an Event  
Filter table with 30 entries that is used to select the actions to perform. Also maintained is a  
fixed/read-only Alert Policy Table entry. No alert strings are supported.  
Note: All Fault/Status LED and ID LED behaviors are driven off of PEF. PEF should not be  
disabled and the default entry configuration should not be modified or those behaviors will be  
changed.  
Each time the PEF module receives either an externally or internally generated event message, it  
compares the event data against the entries in the event filter table. The National Semiconductor  
PC87431 integrated management controller scans all entries in the table and determines a set of  
actions to be performed. If a combination of actions is identified, such as power down, power  
cycle, and/or reset actions, the action are performed according to PEF Action Priorities. Action  
priorities are outlined in  
Table 50.  
Note: An action that has changed from delayed to non-delayed, or an action whose delay time  
has been reduced has a higher priority. Each generated event is logged by SEL.  
85  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Table 50: PEF Action Priorities  
Action  
Power-down  
Priority  
Delayed  
Yes  
Type  
Note  
1
PEF Action  
Soft shut-down  
2
3
4
5
6
7
8
9
Yes  
Yes  
Yes  
No  
OEM PEF Action  
Not executed if a power-down action was  
also selected.  
Power cycle  
PEF Action  
Not executed if a power-down action was  
also selected.  
Reset  
PEF Action  
Not executed if a power-down action was  
also selected.  
Diagnostic Interrupt  
PET Alert  
PEF Action  
Not executed if a power-down action was  
also selected.  
No  
PEF Action  
When selected, always occurs immediately  
after detection of a critical event.  
Sensor feedback  
IPMB message event  
Fault LED action  
No  
OEM PEF Action  
OEM PEF Action  
OEM PEF Action  
When selected, always occurs immediately  
after detection of a critical event.  
No  
When selected, always occurs immediately  
after detection of a critical event.  
When selected, always occurs immediately  
after detection of a critical event, and is  
stopped after the de-assertion of all critical  
events that requested LED blinking.  
No  
Identification LED action  
10  
No  
OEM PEF Action  
When selected, always occurs immediately  
after detection of a critical event.  
Table 51. National Semiconductor PC87431 integrated management controller Factory Default  
Event Filters  
Event Filter #  
Offset Mask  
Events  
1
Non-critical  
Non-critical  
Critical  
Voltage Assert  
Voltage Deassert  
Voltage Assert  
2
3
4
5
6
Critical  
Critical  
Critical  
Voltage Deassert  
PS Soft Fail Assert  
PS Soft Fail Deassert  
7
8
9
Critical  
Critical  
Proc 1-2 Thermal Trip Assert  
Proc 1-2 Thermal Trip, Config Error & IERR Deassert  
Proc 1-2 FRB3 Assert  
Proc 1-2 FRB3 Deassert  
Proc 1-2 Hot Assert  
Proc 1-2 Hot Deassert  
FP NMI Assert  
FP NMI Deassert  
Degraded  
Degraded  
Degraded  
Degraded  
Critical  
10  
11  
12  
13  
14  
15  
16  
17  
Critical  
Non Critical  
Non Critical  
N/A  
SCSI Terminator Fail Assert  
SCSI Terminator Fail Deassert  
ID Button Assert  
86  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Events  
Event Filter #  
Offset Mask  
18  
N/A  
ID Button Deassert  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
Critical  
Critical  
Non Critical  
Non Critical  
Critical  
Fan Speed Assert  
Fan Speed Deassert  
Fan Speed Assert  
Fan Speed Deassert  
Temperature Assert  
Temperature Deassert  
Temperature Assert  
Temperature Deassert  
Proc 1-2 IERR Assert  
CPU Configuration Error  
Reserved for ISM  
Critical  
Non Critical  
Non Critical  
Critical  
Critical  
N/A  
N/A  
Reserved for ISM  
5.1.12.2  
Alert over LAN  
LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps to a specified alert  
destination. The Alert over LAN feature is used to send either Platform Event Trap alerts or  
directed events to a remote system management application, regardless of the state of the  
host’s operating system. LAN alerts may be sent over any of the LAN channels supported by a  
platform. LAN alerts can be used by PEF to send out alerts to selected destination when ever  
an event matches an event filter table entry For more information on LAN alerts, see the IPMI  
Specification v1.5.  
5.1.12.3  
System Identification in Alerts  
The PET alert format used in PPP and LAN Alerting contains a system GUID field that can be  
used to uniquely identify the system that raised the alert. In addition, since the PET is carried in  
a UDP packet, the alerting system’s IP Address is also present.  
5.1.12.4  
Platform Alerting Setup  
The management controller provides commands via the System Interface that support  
setting/retrieving the alerting configuration LAN alerting in National Semiconductor PC87431  
integrated management controller NV storage.  
The user does not typically deal with filter contents directly. Instead, the Server Setup Utility  
provides a user interface that allows the user to select among a fixed set of pre-configured  
event filters.  
87  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
The following list presents the type of Alerting configuration options that are provided:  
Enabling/Disabling PEF.  
Configuring Alert actions.  
Selecting which pre-configured events trigger an alert.  
Generating a ‘test’ event to allow the paging configuration to be checked.  
Configuring the serial/modem and PPP communication and link parameters.  
Configuring the alert destination information, including LAN addresses, phone numbers,  
Alert strings, etc.  
Configuring the PPP Accounts for PPP Alerting (PPP Accounts represent the phone  
number and user login information necessary to connect to a remote system via PPP).  
5.1.12.5  
Alerting On Power Down Events  
The National Semiconductor PC87431 integrated management controller is capable of  
generating alerts while the system is powered down. A watchdog power-down event alert is sent  
after the power down so that the alert does not delay the power-down action.  
5.1.12.6  
Alerting On System Reset Events  
Reset event alerts occur after the reset. The alerting process must complete before the system  
reset is completed. This is done to simplify timing interactions between the National  
Semiconductor PC87431 integrated management controller and BIOS initialization after a  
system reset.  
5.1.12.7  
Alert-in-Progress Termination  
An alert in progress will be terminated by a system reset or power on, or by disabling alerting via  
commands to the management controller.  
5.1.13  
NMI Generation  
The following may cause the National Semiconductor PC87431 integrated management  
controller to generate an NMI pulse:  
Receiving a Chassis Control command issued from one of the command interfaces. Use  
of this command will not cause an event to be logged in the SEL.  
Detecting that the front panel Diagnostic Interrupt button has been pressed.  
A PEF table entry matching an event where the filter entry has the NMI action indicated.  
A processor IERR or Thermal Trip (if the National Semiconductor PC87431 integrated  
management controller is so configured).  
Watchdog timer pre-timeout expiration with NMI pre-timeout action enabled.  
The National Semiconductor PC87431 integrated management controller-generated NMI pulse  
duration is 200ms. This time is chosen to try to avoid the BIOS missing the NMI if the BIOS is in  
the SMI Handler and the SMI Handler is masking the NMI.  
Once an NMI has been generated by the National Semiconductor PC87431 integrated  
management controller, the National Semiconductor PC87431 integrated management  
88  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
controller will not generate another NMI until the system has been reset or powered down,  
however, enabling NMI via an NMI Enable/Disable command will re-arm the NMI.  
The National Semiconductor PC87431 integrated management controller captures the NMI  
source(s) and makes that information available via a Get NMI Source command. Reading the  
NMI source information causes it to be cleared. A second Set NMI Source command can be  
used by other agents, such as the BIOS SMI Handler, to register NMI sources when they detect  
NMI generating errors. Operating system NMI handlers that save the system crash state can  
use the Get NMI Source command to determine and save the cause of the NMI.  
5.1.14  
SMI Generation  
The National Semiconductor PC87431 integrated management controller can generate an SMI  
due to watchdog timer pre-timeout expiration with SMI pre-timeout interrupt specified. The SMI  
generation is software configurable. The above conditions may or may not be enabled to cause  
an SMI.  
5.2 Platform Management Interconnects  
5.2.1  
Power Supply Interface Signals  
The National Semiconductor PC87431 integrated management controller supports two power  
supply control signals: Power On and Power Good. The Power On signal connects to the  
chassis power subsystem and is used to request power state changes (asserted = request  
Power On). The Power Good signal from the chassis power subsystem indicates current the  
power state (asserted = power is on).  
Figure 13 shows the power supply control signals and their sources. To turn the system on, the  
National Semiconductor PC87431 integrated management controller asserts the Power On  
signal and waits for the Power Good signal to assert in response, indicating that DC power is  
on.  
mBMC  
Power ON  
Power Good  
Power Sub System  
Figure 13: Power Supply Control Signals  
89  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
The National Semiconductor PC87431 integrated management controller uses the Power Good  
signal to monitor whether the power supply is on and operational, and to confirm whether the  
actual system power state matches the intended system on/off power state that was  
commanded with the Power On signal.  
De-assertion of the Power Good signal generates an interrupt that the National Semiconductor  
PC87431 integrated management controller uses to detect either power subsystem failure or  
loss of AC power. If AC power is suddenly lost, the National Semiconductor PC87431 integrated  
management controller:  
1. Immediately asserts system reset  
2. Powers down the system  
3. Waits for configured system off time (depending on configuration)  
4. Attempts to power the system on (depending on configuration)  
5.2.1.1  
Power-up Sequence  
When turning on the system power in response to one of the event occurrences listed in  
Table 52 below, the National Semiconductor PC87431 integrated management controller  
executes the following procedure:  
1. The National Semiconductor PC87431 integrated management controller asserts Power  
On and waits for the power subsystem to assert Power Good. The system is held in  
reset.  
2. The National Semiconductor PC87431 integrated management controller sends a Set  
ACPI Power State command, indicating an S0 state to all management controllers  
whose SDR management device records indicate that they should receive the  
notification.  
3. The National Semiconductor PC87431 integrated management controller initializes all  
sensors to their Power On initialization state. The Init Agent is run.  
4. The National Semiconductor PC87431 integrated management controller attempts to  
boot the system by running the FRB algorithm.  
5.2.1.2  
Power-down Sequence  
To power down the system, the National Semiconductor PC87431 integrated management  
controller effectively performs the sequence of power-up steps in reverse order. This operation  
can be initiated by one of the event occurrences listed in Table 52 and proceeds as follows:  
1. The National Semiconductor PC87431 integrated management controller asserts system  
reset (de-asserts Power Good).  
2. If enabled, the National Semiconductor PC87431 integrated management controller  
sends a Set ACPI Power State command, indicating an S0 state to all management  
controllers whose SDR management device records indicate that they should receive  
the notification.  
3. The National Semiconductor PC87431 integrated management controller de-asserts the  
Power On signal.  
4. The power subsystem turns off system power upon de-assertion of the Power On signal.  
90  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.2.1.3  
Power Control Sources  
The sources listed in the following table can initiate power-up and/or power-down activity.  
Table 52: Power Control Initiators  
External Signal Name or  
#
Source  
Power Button  
Capabilities  
Turns power ON or OFF  
Internal Subsystem  
FP Power button  
1
National Semiconductor  
PC87431 integrated  
management controller  
Watchdog Timer  
Internal National Semiconductor  
PC87431 integrated management  
controller timer  
Turns power OFF, or power cycle  
2
3
4
Platform Event Filtering  
Command  
Power state retention  
PEF  
Turns power OFF, or power cycle  
Turns power ON or OFF, or power cycle  
Turns power ON when AC power returns  
Routed through command processor  
Implemented via National  
5
6
Semiconductor PC87431 integrated  
management controller internal logic  
Chipset  
sleep S5  
Turns power ON or OFF  
5.2.2  
System Reset Control  
5.2.2.1  
Reset Signal Output  
The National Semiconductor PC87431 integrated management controller asserts the System  
Reset signal on the baseboard to perform a system reset. The National Semiconductor  
PC87431 integrated management controller asserts the System Reset signal before powering  
the system up. After power is stable (as indicated by the power subsystem Power Good signal),  
the National Semiconductor PC87431 integrated management controller sets the processor  
enable state as appropriate and de-asserts the System Reset signal, taking the system out of  
reset.  
To reset the system without a power state change, the National Semiconductor PC87431  
integrated management controller:  
1. Asserts the System Reset signal.  
2. Holds this state for as long as the reset button is pushed. When a command is used to  
generate a system reset, the state is held for the stipulated time.  
3. De-asserts the System Reset signal.  
91  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.2.2.2  
Reset Control Sources  
The following table shows the reset sources and the actions taken by the system.  
Table 53: System Reset Sources and Actions  
#
Reset Source  
Standby power comes up  
System Reset?  
PC87431 Reset  
1
No (no DC power)  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
2
3
4
5
6
7
8
9
Main system power comes up  
Reset button or in-target probe (ITP) reset  
Warm boot (example: DOS Ctrl-Alt-Del)  
Command to reset the system  
Set Processor State command  
Watchdog timer configured for reset  
FRB3 failure  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Optional  
PEF action  
5.2.3  
Temperature-based Fan Speed Control  
Baseboard hardware implements an ambient-temperature-based Fan Speed control that is part  
of normal system operation. With one exception, the management controller does not  
participate in fan speed control. The feature allows the baseboard to drive different fan speeds  
based on various temperature measurements in order to lower the acoustic noise of the system.  
The ambient-temperature thresholds at which the Fan Speed increases does not correspond to  
a non-critical (warning) condition for the fan - since the fan’s state is still ‘OK’ from the system  
point-of-view.  
The baseboard has two analog Fan Speed signals that are driven by pulse-width modulator  
(PWM) circuits by the baseboard hardware. These signals can be driven to several levels  
according to temperature measurements. Multiple bytes of a Sensor Initialization Table is used  
to hold parameters that set the temperature thresholds and corresponding PWM duty cycles.  
This SDR or table is loaded as part of the baseboard configuration.  
The management controller firmware expects to find an LM30 temperature sensor on the front  
panel board. Thus, the ambient temperature-based fan speed control capability is not enabled  
by default, but can be enabled via a management controller configuration change.  
5.2.3.1  
Fan Kick Start  
Some fans may not begin rotating unless started at high speed. To ensure that the fans start,  
the baseboard hardware will start and run the fans at high speed for a brief interval following  
system power up.  
92  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.2.4  
Front Panel Control  
The National Semiconductor PC87431 integrated management controller provides the main  
front panel control functions. These include control of the system Power Button, Reset Button,  
Diagnostic Interrupt (Front Panel NMI) Button, System Identify Button, System ID LED,  
Status/Fault LED, and Chassis Intrusion Switch. Front panel control also includes the front  
panel lockout features.  
5.2.4.1  
Power Button  
After de-bouncing the front panel Power Button signal, the National Semiconductor PC87431  
integrated management controller routes the signal state directly to the chipset Power Button  
signal input. If the chipset has been initialized by the BIOS, the chipset responds to the  
assertion of the signal by requesting a power state change. It reacts to the press of the switch,  
not the release of it.  
The Power Button signal toggles the system power. The Power Button signal to the National  
Semiconductor PC87431 integrated management controller is activated by a momentary  
contact switch on the front panel assembly. The National Semiconductor PC87431 integrated  
management controller de-bounces the signal. After de-bouncing the signal, the National  
Semiconductor PC87431 integrated management controller routes it directly to the chipset via  
the Power Button signal. The chipset responds to the assertion of the signal. It responds to the  
press of the switch, not the release of it.  
If the system is in Secure Mode or the Power Button is forced protected, then when the power  
switch is pressed, a Platform Security Violation Attempt event message is generated and no  
power control action is taken.  
In the case of simultaneous button presses, the Power Button action takes priority over all other  
buttons. For example, if the sleep button is depressed for one second and then the Power  
Button is pressed and released, the system powers down. Due to the routing of the de-bounced  
Power Button signal to the chipset, the power signal action overrides the action of the other  
switch signals.  
5.2.4.2  
Reset Button  
The reset button is a momentary contact button on the front panel. Its signal is routed through  
the front panel connector to the National Semiconductor PC87431 integrated management  
controller, which monitors and de-bounces it. The signal must be stable for at least 25ms before  
a state change is recognized.  
An assertion of the front Panel Reset signal to the National Semiconductor PC87431 integrated  
management controller causes the National Semiconductor PC87431 integrated management  
controller to start the reset and reboot process. This action is immediate and without the  
cooperation of any software or operating system running on the system.  
If Secure Mode is enabled or the button is forced protected, the reset button does not reset the  
system, but instead a Platform Security Violation Attempt event message is generated. The  
reset button is disabled in sleep mode.  
93  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.2.4.3  
Diagnostic Interrupt Button (Front Panel NMI)  
As stated in the IPMI 1.5 Specification, a Diagnostic Interrupt is a non-maskable interrupt or  
signal for generating diagnostic traces and core dumps from the operating system. The National  
Semiconductor PC87431 integrated management controller generates the NMI, which can be  
used as an OEM-specific diagnostic front panel interface.  
The Diagnostic Interrupt button is connected to the National Semiconductor PC87431 integrated  
management controller through the front panel connector. A Diagnostic Interrupt button press  
causes the National Semiconductor PC87431 integrated management controller to generate a  
system NMI pulse whose duration is platform-specific and unrelated to the button press  
duration.  
This generates an event (NMI button sensor) and PEF OEM action causes NMI generation.  
5.2.4.4  
Chassis ID Button and LED  
The front panel interface supports a Chassis Identify Button and a corresponding Blue Chassis  
Identify LED. A second Blue Chassis Identify LED is mounted on the back edge of the  
baseboard where it may be visible when viewed from the back of an integrated system.  
The LED can provide a mechanism for identifying one system out of a group of identical  
systems in a high density rack environment  
The Chassis Identify LED can be turned on either locally via the push-button signal, or by local  
or remote software using the IPMI Chassis Identify command. The following list summarizes the  
Chassis Identify Push-button and LED operation:  
The Identify signal state is preserved on Standby power across system power-on/off and  
system hard resets. It is not preserved if A/C power is removed. The initial LED state is  
Off when A/C power is applied.  
The IPMI Chassis Identify command can also be used to control the LED. If a the  
Chassis Identify command is used to turn the LED On, the command will automatically  
time out and turn off the LED unless another Chassis Identify command to turn on the  
LED is received. The default timeout for the command is 15 seconds. The baseboard  
supports the optional command parameter to allow the timeout to be set anywhere from  
1 to 255 seconds.  
The optional timeout parameter in the Chassis Identify command also allows software to  
tell the LED to go Off immediately.  
The Chassis Identify Pushbutton works using a “push-on/push-off” operation. Each press  
of the push-button toggles the LED signal state between On and Off. If the pushbutton is  
used to turn the LED On, it will stay on indefinitely, until either the button is pressed  
again or a Chassis Identify or Chassis Identify LED command causes the LED to go Off.  
Table 54: Chassis ID LEDs  
Color Condition  
When  
94  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Off  
Blink  
Ok  
Identify button pressed or Chassis Identify command executed  
Blue  
5.2.4.5  
Status/Fault LED  
The following table shows mapping of sensors/faults to the LED state.  
Table 55: Fault/Status LED  
Color  
Condition  
When  
Solid  
System Ready  
Green  
Blink  
Solid  
Blink  
Solid  
System Ready, but degraded. CPU fault, DIMM killed  
Critical Failure: critical fan, voltage, temperature state  
Non-Critical Failure: non-critical fan, voltage, temperature state  
Not Ready. POST error/NMI event/CPU or terminator missing  
Amber  
Off  
Critical Condition  
Any critical or non-recoverable threshold crossing associated with the following events:  
Temperature, voltage, or fan critical threshold crossing  
Power subsystem failure. The National Semiconductor PC87431 integrated  
management controller asserts this failure whenever it detects a power control fault  
(e.g., the National Semiconductor PC87431 integrated management controller detects  
that the system power is remaining on even though the National Semiconductor  
PC87431 integrated management controller has de-asserted the signal to turn off power  
to the system). A hot-swap backplane would use the Set Fault Indication command to  
indicate when one or more of the drive fault status LEDs are asserted on the hot-swap  
backplane  
The system is unable to power up due to incorrectly installed processor(s), or processor  
incompatibility  
Satellite controller sends a critical or non-recoverable state, via the Set Fault Indication  
command to the National Semiconductor PC87431 integrated management controller  
“Critical Event Logging” errors, including: System Memory Uncorrectable ECC error and  
Fatal/Uncorrectable Bus errors, such as PCI SERR and PERR  
Non-Critical Condition  
Temperature, voltage, or fan non-critical threshold crossing  
Chassis intrusion  
Satellite controller sends a non-critical state, via the Set Fault Indication command, to  
the National Semiconductor PC87431 integrated management controller  
Set Fault Indication command from system BIOS. The BIOS may use the Set Fault  
Indication command to indicate additional, non-critical status such as system memory or  
CPU configuration changes  
95  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Degraded Condition  
Platform Management Architecture  
One or more processors are disabled by Fault Resilient Boot (FRB) or BIOS  
BIOS has disabled or mapped out some of the system memory  
5.2.4.6  
Chassis Intrusion Switch  
The server board SE7210TP1-E supports chassis intrusion detection. The National  
Semiconductor PC87431 integrated management controller monitors the state of the Chassis  
Intrusion signal and makes the status of the signal available via the Get Chassis Status  
command and Physical Security sensor state. If enabled, a chassis intrusion state change  
causes the National Semiconductor PC87431 integrated management controller to generate a  
Physical Security sensor event message with a General Chassis Intrusion offset.  
5.2.4.7  
Front Panel Lockout  
The management controller monitors a ‘Secure Mode’ signal from the keyboard controller on the  
baseboard. When the Secure Mode signal is asserted, the management controller may lock out  
the ability to power down or reset the system using the power or reset push buttons,  
respectively. Secure Mode may also block the ability to initiate a sleep request using the Sleep  
push-button.  
The management controller generates a ‘Secure Mode Violation Attempt’ event message if an  
attempt it made to power-down, sleep, or reset the system using the push buttons while Secure  
Mode is active.  
Note: The National Semiconductor PC87431 integrated management controller will prevent the  
system from powering up via button press when either secure mode or the front panel lockout  
I/O signal is asserted.  
5.2.5  
Secure Mode Operation  
Secure mode is a signal from the SIO/keyboard controller. Power and reset buttons are locked  
out, except for the NMI and Chassis ID buttons. A security violation event is generated if buttons  
are pressed while secure mode is active.  
The Secure Mode feature allows the front panel switches and other system resources to be  
protected against unauthorized use or access. Secure Mode is enabled and controlled via the  
Set Secure Mode Options command.  
If it is enabled, Secure Mode can be controlled via the Secure Mode KB signal from the  
keyboard controller. When Secure Mode is active, pressing a protected front panel switch  
generates a Secure Mode Violation event. Specifically, this generates an assertion of the  
Secure Mode Violation Attempt offset of the National Semiconductor PC87431 integrated  
management controller’s Platform Security Violation Attempt sensor.  
The Secure Mode state is cleared whenever AC power or system power is applied, when a  
system reset occurs, or when a National Semiconductor PC87431 integrated management  
controller reset occurs. The Secure Mode state includes the bits that specify the actions that are  
to be taken when Secure Mode is active, as well as the Force Secure Mode On bit.  
96  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
The Set Secure Mode Options command allows specific front panel switches to be protected  
irrespective of Secure Mode state. Please see the command definition in the IPMI v1.5  
specification for details.  
The NMI switch can be locked using the Set Secure Mode Options command but is never  
protected by Secure Mode. This allows a system to be recovered from a hung state when  
Secure Mode is active.  
5.2.6  
FRU Information  
The platform management architecture supports providing FRU (Field Replaceable Unit)  
information for the baseboard and major replaceable modules in the chassis. ‘Major Module’ is  
defined as any circuit board in the system containing active electronic circuitry.  
FRU information includes board serial number, part number, name, asset tag, and other  
information. FRUs that contain a management controller use the controller to provide access to  
the FRU information. FRUs that lack a management controller can make their FRU information  
available via a SEEPROM directly connected to the IPMB or a private I2C bus. This allows the  
system integrator to provide a chassis FRU device without having to implement a management  
controller. This information can be accessed via IPMI FRU commands or using Master Write-  
Read commands.  
The National Semiconductor PC87431 integrated management controller implements the  
interface for logical FRU inventory devices as specified in the Intelligent Platform Management  
Interface Specification, Version 1.5. This functionality provides commands used for accessing  
and managing the FRU inventory information associated with the National Semiconductor  
PC87431 integrated management controller (FRU ID 0). These commands can be delivered via  
all interfaces.  
5.2.6.1  
National Semiconductor PC87431 integrated management controller FRU  
Inventory Area Format  
The National Semiconductor PC87431 integrated management controller FRU inventory area  
format follows the Platform Management FRU Information Storage Definition. Refer to Platform  
Management FRU Information Storage Definition, Version 1.0 for details.  
The National Semiconductor PC87431 integrated management controller provides only low-  
level access to the FRU inventory area storage. It does not validate or interpret the data that are  
written. This includes the common header area. Applications cannot relocate or resize any FRU  
inventory areas.  
The baseboard’s FRU information is kept in the National Semiconductor PC87431 integrated  
management controller internal flash memory.  
5.2.7  
LCD Support  
The baseboard supports the addition of an LCD display via an IPMI-compatible management  
controller connected to the IPMB. The system BIOS sends IPMB commands to the display as  
described in the LCD Interface for IPMB specification.  
97  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
5.3 Sensors  
5.3.1  
Sensor Type Codes  
The following tables list the sensor identification numbers and information regarding the sensor  
type, name, supported thresholds, assertion and de-assertion information, and a brief  
description of the sensor purpose. Refer to the Intelligent Platform Management Interface  
Specification, Version 1.5, for sensor and event/reading-type table information.  
Sensor Type  
The Sensor Type references the values enumerated in the Sensor Type Codes table in  
the IPMI specification. It provides the context in which to interpret the sensor, e.g., the  
physical entity or characteristic that is represented by this sensor.  
1
2
Event/Reading Type  
The Event/Reading Type references values from the Event/Reading Type Code  
Ranges and Generic Event/Reading Type Codes tables in the IPMI specification. Note  
that digital sensors are a specific type of discrete sensors, which have only two states.  
Event Offset/Triggers  
Event Thresholds are supported event generating thresholds for threshold types of  
sensors.  
-
-
[u,l][nr,c,nc]  
nonrecoverable, lower critical, lower noncritical  
uc, lc upper critical, lower critical  
upper nonrecoverable, upper critical, upper noncritical, lower  
Event Triggers are supported event generating offsets for discrete type sensors. The  
offsets can be found in the Generic Event/Reading Type Codes or Sensor Type Codes  
tables in the IPMI specification, depending on whether the sensor event/reading type is  
generic or a sensor specific response.  
3
Assertion/De-assertion Enables  
Assertions and De-assertion indicators reveals the type of events the sensor can  
generate:  
-
-
As: Assertions  
De: Deassertion  
4
Readable Value / Offsets  
-
Readable Value indicates the type of value returned for threshold and other non-  
discrete type sensors.  
-
Readable Offsets indicates the offsets for discrete sensors that are readable via the  
Get Sensor Reading command. Unless otherwise indicated, all Event Triggers are  
readable, i.e., Readable Offsets consists of the reading type offsets that do not  
generate events.  
5
Event Data  
This is the data that is included in an event message generated by the associated  
sensor. For threshold-based sensors, the following abbreviations are used:  
-
R: Reading value  
98  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
-
T: Threshold value  
The following table lists the core sensors located within the National Semiconductor PC87431  
integrated management controller. These sensors are fixed and hard-coded. They cannot be  
modified by a user.  
Table 56: National Semiconductor PC87431 integrated management controller Built-in Sensors  
Event /  
Reading  
Type  
Readable  
Value /  
Event Offset  
Triggers  
Assert /  
Sensor Name  
Sensor Type  
EventData  
Deassert  
Offsets  
LAN Leash  
Lost  
Physical Security  
Violation  
01  
02  
Physical  
Security  
05h  
Platform  
Security  
Violation  
Attempt  
06h  
Sensor  
Specific  
6Fh  
LAN Leash Lost  
As  
Trig Offset  
Platform Security  
Violation  
Sensor  
Specific  
6Fh  
Out-of-band  
access password  
violation  
As  
Trig Offset  
Power Unit Status  
Button  
03  
Power Unit  
Sensor  
Specific  
6Fh  
As  
As  
Trig Offset  
Trig Offset  
Power On/Off  
Power cycle  
AC Lost  
09h  
04h Button  
14h  
Sensor  
Specific  
6Fh  
Power Button  
Reset Button  
Timer Expired  
Hard Reset  
Power Down  
Power cycle  
Timer Interrupt  
Sensor  
Specific  
6Fh  
Watchdog2  
23h  
Watchdog  
05h  
As  
Trig Offset  
99  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
The following table shows the baseboard/platform sensors that are supported by the National  
Semiconductor PC87431 integrated management controller.  
Table 57: SE7520JR2 Platform Sensors for Essentials Management  
Event /  
SDR  
Record  
Type  
Sensor  
Type  
Event Offset Assert /  
Readable  
PEF  
Sensor Name  
Reading  
Type  
Event Data  
Triggers  
Deassert Value/Offsets  
Action  
Physical  
Security  
05h  
Sensor  
Specific  
6Fh  
General  
Chassis  
Intrusion  
General  
Physical Security  
Violation  
07h  
As  
Chassis  
Intrusion  
Trig Offset  
X
02  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
CPU1 12v  
CPU2 12v  
BB +1.5V  
08h  
09h  
0Ah  
0Bh  
0Ch  
0Dh  
0Eh  
0Fh  
10h  
11h  
12h  
13h  
14h  
15h  
16h  
17h  
18h  
19h  
[u,l][nr, c,nc] As & De  
[u,l][nr, c,nc] As & De  
[u,l][nr, c,nc] As & De  
[u,l][nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
01  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
BB +1.8V  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
BB +3.3V  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
BB +5V  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
BB +12V  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
BB -12V  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
FSB Vtt  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
MCH Vtt  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
SCSI Core(1.8v)  
Proc1 VCCP  
Proc2 VCCP  
Tach Fan 1  
Tach Fan 2  
Tach Fan 3  
Tach Fan 4  
Tach Fan 5  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
Voltage  
02h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
100  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Platform Management Architecture  
Event /  
Sensor  
SDR  
Record  
Type  
Event Offset Assert /  
Readable  
PEF  
Sensor Name  
Reading  
Type  
Event Data  
Type  
Triggers Deassert Value/Offsets  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Tach Fan 6  
Tach Fan 7  
Tach Fan 8  
Tach Fan 9  
1Ah  
1Bh  
1Ch  
1Dh  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
Analog  
Analog  
Analog  
Analog  
R, T  
R, T  
R, T  
R, T  
01  
01  
01  
01  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Action  
System  
Event  
12h  
Sensor  
Specific  
6Fh  
System Event  
Proc1 IERR  
Proc2 IERR  
1Eh  
1Fh  
20h  
21h  
22h  
PEF Action  
IERR  
As  
As  
As  
As  
As  
Trig Offset  
Trig Offset  
Trig Offset  
Trig Offset  
Trig Offset  
02  
02  
02  
02  
02  
Sensor  
Specific  
6Fh  
Processor  
07h  
Sensor  
Specific  
6Fh  
Processor  
07h  
IERR  
Sensor  
Specific  
6Fh  
Proc1 Thermal  
trip  
Processor  
07h  
Fault LED  
Action  
Thermal Trip  
Thermal Trip  
Sensor  
Specific  
6Fh  
Proc2 Thermal  
trip  
Processor  
07h  
Fault LED  
Action  
Temp  
01h  
Threshold  
01h  
Fault LED  
Action  
Proc1 Throttle  
Proc2 Throttle  
23h  
24h  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
Analog  
Analog  
Trig Offset  
Trig Offset  
01  
01  
Temp  
01h  
Threshold  
01h  
Fault LED  
Action  
Critical  
Interrupt  
13h  
Sensor  
Specific  
6Fh  
Diagnostic  
FP NMI  
As  
25h  
26h  
Trig Offset NMI Pulse  
02  
02  
Interrupt Button  
Button  
Sate  
ID LED  
Trig Offset  
Chassis Identify  
Button  
Button  
14h  
Generic  
03h  
Deasserted  
State Assert  
As & De  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Proc1 Fan  
27h  
28h  
29h  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
[u,l][ nr, c,nc] As & De  
Analog  
Analog  
Analog  
Analog  
R, T  
01  
01  
01  
01  
Action  
Fan  
04h  
Threshold  
01h  
Fault LED  
Proc2 Fan  
R, T  
Action  
Temp  
01h  
Threshold  
01h  
Fault LED  
Proc1 Core temp  
R, T  
Action  
Temp  
01h  
Threshold  
01h  
Fault LED  
Proc2 Core temp 2Ah  
CPU  
R, T  
Action  
Processor  
07h  
Generic  
03h  
State  
Fault LED  
Configuration  
Error  
2Bh  
As & De  
Asserted  
Discrete  
R, T  
02  
Action  
101  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
6. Error Reporting and Handling  
This section documents the types of system bus error conditions monitored by the Intel Server Board  
SE7210TP1-E.  
6.1 Error Sources and Types  
One of the major requirements of server management is to correctly and consistently handle  
system errors. System errors, which can be disabled and enabled individually or as a group, can  
be categorized as follows:  
PCI bus  
Memory single- and multi-bit errors  
Sensors  
Processor internal errors, bus/address errors, thermal trip errors, temperatures and  
voltages, and GTL voltage levels  
Errors detected during POST, logged as ‘POST errors’  
On the SE7210TP1-E platform, the Winbond* chip manages general hardware monitoring  
sensors on a hardware level; however action is only taken by software (i.e., an application such  
as LANDesk™ Client Manager).  
6.1.1  
PCI Bus Errors  
The PCI bus defines two error pins, PERR# and SERR#, for reporting PCI parity errors and  
system errors, respectively. In the case of PERR#, the PCI bus master has the option to retry  
the offending transaction, or to report it using SERR#. All other PCI-related errors are reported  
by SERR#. SERR# is routed to NMI if enabled by BIOS.  
6.1.2  
Processor Bus Errors  
The MCH supports the data integrity features supported by the Pentium® Pro bus, including  
address, request, and response parity. The E7210 chipset always generates ECC data while it  
is driving the processor data bus, although the data bus ECC can be disabled or enabled by  
BIOS. It is enabled by default.  
6.1.3  
Memory Bus Errors  
The MCH is programmed to flag and log multi-bit errors (MBEs). The MCH then triggers an SMI  
to the 6300ESB I/O and the 6300ESB I/O asserts the SMI# signal. BIOS then logs the errors in  
the event log.  
6.2 BIOS Error Messages, POST Codes, and BIOS Beep Codes  
The BIOS indicates the current testing phase during POST by writing a hex code to I/O location  
80h. If errors are encountered, error messages or codes will either be displayed to the video  
screen, or if an error has occurred prior to video initialization, errors will be reported through a  
series of audio beep codes. POST errors are logged in to the SEL.  
102  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
The error codes are defined by Intel and, whenever possible, are backward compatible with  
error codes used on earlier platforms.  
6.2.1  
BIOS Error Messages  
During POST, if an error is detected, the BIOS will display an error code and message to the  
screen. The following table defines POST error codes and their associated messages. The  
BIOS prompts the user to press a key in case of serious errors. Some of the error messages are  
preceded by the string "Error” to highlight the fact that the system may be malfunctioning. All  
POST errors and warnings are logged in the SEL  
Table 58: POST Error Messages and Handling  
Error Code  
0000  
0003  
0004  
0005  
0008  
0009  
000A  
000B  
000C  
000E  
000F  
0010  
0012  
0014  
0040  
0041  
0042  
0043  
0044  
0045  
0046  
0047  
Error Message  
Timer Error  
Response  
Pause  
Pause  
Pause  
Pause  
Halt  
CMOS Battery Low  
CMOS Settings Wrong  
CMOS Checksum Bad  
Unlock Keyboard  
PS2 Keyboard not found  
KBC BAT Test failed  
CMOS memory size different  
RAM R/W test failed  
A: Drive Error  
Not an error  
Halt  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Not an error  
Halt  
Pause  
Pause  
Pause  
Halt  
B: Drive Error  
Floppy Controller Failure  
CMOS Date/Time not set  
PS2 Mouse not found  
Refresh timer test failed  
Display memory test failed  
CMOS Display Type Wrong  
~<INS> Pressed  
DMA Controller Error  
DMA-1 Error  
DMA-2 Error  
Halt  
Halt  
Halt  
Unknown BIOS error. Error code = 147 (this is really a  
PMM_MEM_ALLOC_ERR)  
0048  
0049  
Password check failed  
Unknown BIOS error. Error code = 149 (this is really  
SEGMENT_REG_ERR)  
Halt  
Halt  
004A  
004B  
Unknown BIOS error. Error code = 14A (this is really  
ADM_MODULE_ERR)  
Unknown BIOS error. Error code = 14B (this is really  
LANGUAGE_MODULE_ERR)  
Pause  
Pause  
004C  
004D  
Keyboard/Interface Error  
Primary Master Hard Disk Error  
Pause  
Pause  
103  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
004E  
004F  
0050  
0055  
0056  
0057  
0058  
0059  
005B  
005D  
005E  
0120  
0146  
0147  
0150  
0160  
0180  
0195  
0197  
5120  
5121  
5122  
8104  
Primary Slave Hard Disk Error  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Secondary Master Hard Disk Error  
Secondary Slave Hard Disk Error  
Primary Master Drive - ATAPI Incompatible  
Primary Slave Drive - ATAPI Incompatible  
Secondary Master Drive - ATAPI Incompatible  
Secondary Slave Drive - ATAPI Incompatible  
Third Master Device Error  
Fourth Master Device Error  
S.M.A.R.T. Status BAD, Backup and Replace  
Password check failed  
Thermal failure due to PROCHOT#  
Insufficient Memory to Shadow PCI ROM  
Custom CMOS Defaults loaded  
BSP Processor failed BIST  
Processor missing microcode  
BIOS does not support current stepping  
Front side bus mismatch.  
Processor speeds mismatch.  
CMOS Cleared By Jumper  
Password cleared by jumper  
CMOS Cleared By mBMC Request  
Warning! Port 60h/64h emulation is not supported by this USB Host  
Controller!!!  
Warning  
8105  
Warning! EHCI controller disabled. It requires 64bit data support in the  
BIOS.  
Warning  
8110  
8120  
8140  
8190  
8198  
8300  
8301  
Processor 01 Internal error (IERR)  
Processor 01 Thermal Trip error  
Processor 01 failed FRB level 3 timer  
Watchdog Timer failed on last boot  
OS boot Watchdog Timer Failure  
Baseboard Management Controller failed Self Test  
Not enough space in Runtime area!!. SMBIOS data will not be  
available.  
Warning  
Warning  
Warning  
Warning  
Pause  
Pause  
Pause  
8305  
84F2  
84F3  
84F4  
84FF  
8500  
8501  
8504  
8505  
Primary Hot swap Controller failed to function  
BaseBoard Management Controller failed to respond  
BaseBoard Management Controller in Update Mode  
Sensor Data Record Empty  
System Event Log Full  
Bad or missing memory in slot 2A  
Bad or missing memory in slot 1A  
Bad or missing memory in slot 2B  
Bad or missing memory in slot 1B  
Pause  
Pause  
Pause  
Pause  
Warning  
Pause  
Pause  
Pause  
Pause  
104  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
6.2.2  
Port 80h POST Codes  
During the POST, the BIOS generates diagnostic progress codes (POST codes) to I/O port 80h.  
If the POST fails, execution stops and the last POST code generated is left at port 80h. This  
code is useful for determining the point where an error occurred.  
Table 59: POST Code Checkpoints  
Check  
point  
Diagnostic LED Decoder  
Diagnostic LED Decoder  
G=Green, R=Red, A=Amber  
G=Green, R=Red, A=Amber  
Hi  
Low  
03  
OF  
F
OF  
F
G
G
Disable NMI, Parity, video for EGA, and DMA  
controllers. Initialize BIOS, POST, Runtime data area.  
Also initialize BIOS modules on POST entry and GPNV  
area. Initialized CMOS as mentioned in the Kernel  
Variable "wCMOSFlags."  
04  
OF  
F
G
OF  
F
OF  
F
Check CMOS diagnostic byte to determine if battery  
power is OK and CMOS checksum is OK. Verify CMOS  
checksum manually by reading storage area. If the  
CMOS checksum is bad, update CMOS with power-on  
default values and clear passwords. Initialize status  
register A.  
Initializes data variables that are based on CMOS setup  
questions. Initializes both the 8259 compatible PICs in  
the system  
05  
06  
OF  
F
OF  
F
G
G
OF  
F
G
G
Initializes the interrupt controlling hardware (generally  
PIC) and interrupt vector table.  
Do R/W test to CH-2 count reg. Initialize CH-0 as  
system timer. Install the POSTINT1Ch handler. Enable  
IRQ-0 in PIC for system timer interrupt.  
OF  
F
Traps INT1Ch vector to "POSTINT1ChHandlerBlock."  
08  
G
OF  
F
OF  
F
OF  
F
Initializes the CPU. The BAT test is being done on KBC.  
Program the keyboard controller command byte is being  
done after Auto detection of KB/MS using AMI KB-5.  
C0  
C1  
C2  
C5  
C6  
R
R
R
R
R
R
R
R
A
A
A
OF  
F
OF  
F
OF  
F
G
Early CPU Init Start -- Disable Cache - Init Local APIC  
Set up boot strap processor Information  
G
OF  
F
G
Set up boot strap processor for POST  
OF  
F
G
Enumerate and set up application processors  
Re-enable cache for boot strap processor  
OF  
F
G
OF  
F
C7  
0A  
R
G
G
G
Early CPU Init Exit  
Initializes the 8042 compatible Key Board Controller.  
OF  
F
0B  
0C  
G
G
OF  
F
G
G
G
Detects the presence of PS/2 mouse.  
OF  
F
OF  
F
Detects the presence of Keyboard in KBC port.  
105  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
0E  
G
G
G
OF  
F
Testing and initialization of different Input Devices. Also,  
update the Kernel Variables.  
Traps the INT09h vector, so that the POST INT09h  
handler gets control for IRQ1. Uncompress all available  
language, BIOS logo, and Silent logo modules.  
13  
24  
30  
2A  
OF  
F
OF  
F
OF  
F
G
OF  
F
G
G
R
R
A
A
Early POST initialization of chipset registers.  
OF  
F
R
Uncompress and initialize any platform specific BIOS  
modules.  
Initialize System Management Interrupt.  
OF  
F
OF  
F
OF  
F
Initializes different devices through DIM.  
See DIM Code Checkpoints section of document for  
more information.  
2C  
G
G
G
G
R
OF  
F
Initializes different devices. Detects and initializes the  
video adapter installed in the system that have optional  
ROMs.  
2E  
31  
A
R
OF  
F
A
Initializes all the output devices.  
OF  
F
OF  
F
Allocate memory for ADM module and uncompress it.  
Give control to ADM module for initialization. Initialize  
language and font modules for ADM. Activate ADM  
module.  
33  
37  
38  
39  
3A  
3B  
OF  
F
OF  
F
G
G
G
G
OF  
F
G
A
A
R
R
A
A
A
A
R
A
R
A
Initializes the silent boot module. Set the window for  
displaying text information.  
Displaying sign-on message, CPU information, setup  
key message, and any OEM specific information.  
Initializes different devices through DIM. See DIM Code  
Checkpoints section of document for more information.  
Initializes DMAC-1 & DMAC-2.  
OF  
F
OF  
F
OF  
F
OF  
F
Initialize RTC date/time.  
Test for total memory installed in the system. Also,  
Check for DEL or ESC keys to limit memory test.  
Display total memory in the system.  
3C  
40  
G
OF  
F
G
R
R
OF  
F
R
OF  
F
Mid POST initialization of chipset registers.  
Detect different devices (Parallel ports, serial ports, and  
coprocessor in CPU, … etc.) successfully installed in the  
system and update the BDA, EBDA…etc.  
50  
52  
OF  
F
R
R
OF  
F
R
R
Programming the memory hole or any kind of  
implementation that needs an adjustment in system  
RAM size if needed.  
Updates CMOS memory size from memory found in  
memory test. Allocates memory for Extended BIOS Data  
Area from base memory.  
OF  
F
G
60  
75  
78  
OF  
F
OF  
F
R
A
R
R
R
R
OF  
F
A
Initializes NUM-LOCK status and programs the KBD  
typematic rate.  
Initialize Int-13 and prepare for IPL detection.  
G
R
Initializes IPL devices controlled by BIOS and option  
ROMs.  
106  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
7A  
7C  
84  
G
G
R
R
A
G
A
R
OF  
F
R
R
OF  
F
Initializes remaining option ROMs.  
Generate and write contents of ESCD in NVRam.  
Log errors encountered during POST.  
85  
R
G
OF  
F
G
Display errors to the user and gets the user response  
for error.  
87  
8C  
R
A
G
G
G
OF  
F
G
OF  
F
Execute BIOS setup if needed / requested.  
Late POST initialization of chipset registers.  
8D  
8E  
90  
A0  
A1  
A2  
A
A
R
R
R
R
G
G
OF  
F
G
G
Build ACPI tables (if ACPI is supported)  
OF  
F
R
Program the peripheral parameters. Enable/Disable  
NMI as selected  
Late POST initialization of system management  
interrupt.  
OF  
F
OF  
F
OF  
F
OF  
F
OF  
F
R
R
A
OF  
F
G
Check boot password if installed.  
Clean-up work needed before booting to OS.  
OF  
F
Takes care of runtime image preparation for different  
BIOS modules. Fill the free area in F000h segment with  
0FFh. Initializes the Microsoft IRQ Routing Table.  
Prepares the runtime language module. Disables the  
system configuration display if needed.  
A4  
A7  
R
R
G
G
R
A
OF  
F
G
Initialize runtime language module.  
Displays the system configuration screen if enabled.  
Initialize the CPU’s before boot, which includes the  
programming of the MTRR’s.  
A8  
A9  
AA  
AB  
AC  
B1  
00  
A
A
A
A
A
R
OF  
F
OF  
F
OF  
F
OF  
F
R
R
A
A
R
R
OF  
F
G
Prepare CPU for OS boot including final MTRR values.  
Wait for user input at config display if needed.  
OF  
F
G
Uninstall POST INT1Ch vector and INT09h vector. De-  
initializes the ADM module.  
Prepare BBS for Int 19 boot.  
G
OF  
F
A
End of POST initialization of chipset registers.  
Save system context for ACPI.  
OF  
F
OF  
F
OF  
F
OF  
F
OF  
F
Passes control to OS Loader (typically INT19h).  
Table60: Bootblock Initialization Code Checkpoints  
Check  
Diagnostic LED Decoder  
G=Green, R=Red,  
A=Amber  
Diagnostic LED Decoder  
G=Green, R=Red, A=Amber  
107  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
point  
Error Reporting and Handling  
Hi  
Low  
A
A
A
A
Early chipset initialization is done. Early super I/O initialization is done  
including RTC and keyboard controller. NMI is disabled.  
Before  
D1  
D1  
R
R
OFF  
A
Perform keyboard controller BAT test. Check if waking up from power  
management suspend state. Save power-on CPUID value in scratch  
CMOS.  
D0  
D2  
D3  
R
R
R
R
R
R
OFF  
G
R
R
A
Go to flat mode with 4GB limit and GA20 enabled. Verify the bootblock  
checksum.  
Disable CACHE before memory detection. Execute full memory sizing  
module. Verify that flat mode is enabled.  
If memory sizing module not executed, start memory refresh and do  
memory sizing in Bootblock code. Do additional chipset initialization. Re-  
enable CACHE. Verify that flat mode is enabled.  
G
D4  
D5  
D6  
R
R
R
A
A
A
OFF  
OFF  
G
R
A
R
Test base 512KB memory. Adjust policies and cache first 8MB. Set stack.  
Bootblock code is copied from ROM to lower system memory and control  
is given to it. BIOS now executes out of RAM.  
Both key sequence and OEM specific method is checked to determine if  
BIOS recovery is forced. Main BIOS checksum is tested. If BIOS recovery  
is necessary, control flows to checkpoint E0. See Bootblock Recovery  
Code Checkpoints section of document for more information.  
D7  
R
A
G
A
Restore CPUID value back into register. The Bootblock-Runtime interface  
module is moved to system memory and control is given to it. Determine  
whether to execute serial flash.  
D8  
D9  
A
A
R
R
OFF  
OFF  
R
A
The Runtime module is uncompressed into memory. CPUID information is  
stored in memory.  
Store the Uncompressed pointer for future use in PMM. Copying Main  
BIOS into memory. Leaves all RAM below 1MB Read-Write including E000  
and F000 shadow areas but closing SMRAM.  
DA  
A
R
G
R
Restore CPUID value back into register. Give control to BIOS POST  
(ExecutePOSTKernel). See POST Code Checkpoints section of document  
for more information.  
6.2.2.1  
Bootblock Recovery Code Checkpoints  
The Bootblock recovery code gets control when the BIOS determines that a BIOS recovery needs to occur because  
the user has forced the update or the BIOS checksum is corrupt. The following table describes the type of  
checkpoints that may occur during the Bootblock recovery portion of the BIOS:  
108  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
Table61: Bootblock Recovery Code Checkpoints  
Check  
point  
Diagnostic LED Decoder  
G=Green, R=Red,  
A=Amber  
Diagnostic LED Decoder  
G=Green, R=Red, A=Amber  
Hi  
Low  
E0  
R
R
R
OFF  
Initialize the floppy controller in the super I/O. Some interrupt vectors are  
initialized. DMA controller is initialized. 8259 interrupt controller is  
initialized. L1 cache is enabled.  
E9  
EA  
A
A
R
R
R
A
G
Set up floppy controller and data. Attempt to read from floppy.  
OFF  
Enable ATAPI hardware. Attempt to read from ARMD and ATAPI  
CDROM.  
EB  
EF  
E9 or  
EA  
A
A
A
(A)  
R
R
R
R
A
R
(R)  
R
A
A
G
G
R
(OFF)  
R
A
R
Disable ATAPI hardware. Jump back to checkpoint E9.  
Read error occurred on media. Jump back to checkpoint EB.  
Determine information about root directory of recovery media.  
R
(A)  
R
R
A
F0  
F1  
F2  
Search for pre-defined recovery file name in root directory.  
Recovery file not found.  
Start reading FAT table and analyze FAT to find the clusters occupied  
by the recovery file.  
R
R
F3  
F5  
FA  
R
R
A
R
A
R
A
R
A
A
A
R
Start reading the recovery file cluster by cluster.  
Disable L1 cache.  
Check the validity of the recovery file configuration to the current  
configuration of the flash part.  
FB  
A
R
A
A
Make flash write enabled through chipset and OEM specific method.  
Detect proper flash part. Verify that the found flash part size equals the  
recovery file size.  
F4  
R
A
R
R
The recovery file size does not equal the found flash part size.  
FC  
FD  
FF  
A
A
A
A
A
A
R
R
A
R
A
A
Erase the flash part.  
Program the flash part.  
The flash has been updated successfully. Make flash write disabled.  
Disable ATAPI hardware. Restore CPUID value back into register. Give  
control to F000 ROM at F000:FFF0h.  
6.2.2.2  
BIOS Beep Codes  
Whenever a recoverable error occurs during POST, the BIOS displays an error message  
describing the problem. The BIOS also issues a beep code (one long tone followed by two short  
tones) during POST if the video configuration fails (a faulty video card or no card installed) or if  
an external ROM module does not properly checksum to zero.  
An external ROM module (for example, a video BIOS) can also issue audible errors, usually  
consisting of one long tone followed by a series of short tones. For more information on the  
beep codes issued, check the documentation for that external device.  
109  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
There are several POST routines that issue a POST terminal error and shut down the system if  
they fail. Before shutting down the system, the terminal-error handler issues a beep code  
signifying the test point error, writes the error to I/O port 80h, attempts to initialize the video and  
writes the error in the upper left corner of the screen (using both monochrome and color  
adapters).  
If POST completes normally, the BIOS issues one short beep before passing control to the  
operating system.  
Table62 : POST Error Beep Codes  
Beeps  
Error Message  
POST Progress Code  
Description  
1
Refresh timer test  
Display message and  
failed  
beeps.  
3
6
RAM R/W test failed  
KBC BAT Test failed  
Display message and  
beeps.  
Display message and  
beeps.  
6.2.2.3  
BIOS Recovery Beep Codes  
Table63 : BIOS Recovery Beep Codes  
Beeps  
1
2 then 5  
Error Message  
Recovery Started  
Recovery Boot Error  
POST Progress Code  
E9h  
Flashing series of POST  
codes: EFh, F1h,cycle.  
Description  
Start of recovery process  
Unable to boot to floppy, ATAPI, or  
ATAPI CD-ROM. Recovery process will  
retry.  
6.3 Bus Initialization Checkpoints  
The system BIOS gives control to the different buses at several checkpoints to do various tasks.  
Table 64 describes the bus initialization checkpoints.  
Table 64. Bus Initialization Checkpoints  
Checkpoint  
2A  
38  
Description  
Different buses init (system, static, and output devices) to start if present.  
Different buses init (input, IPL, and general devices) to start if present.  
While control is inside the different bus routines, additional checkpoints are output to port 80h  
as WORD to identify the routines under execution. In these WORD checkpoints, the low byte of  
the checkpoint is the system BIOS checkpoint from which the control is passed to the different  
bus routines. The high byte of the checkpoint is the indication of which routine is being executed  
in the different buses. Table 65 describes the upper nibble of the high byte and indicates the  
function that is being executed.  
Table 65. Upper Nibble High Byte Functions  
Value  
Description  
0
func#0, disable all devices on the bus concerned.  
110  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Error Reporting and Handling  
1
2
3
4
5
6
7
8
func#1, static devices init on the bus concerned.  
func#2, output device init on the bus concerned.  
func#3, input device init on the bus concerned.  
func#4, IPL device init on the bus concerned.  
func#5, general device init on the bus concerned.  
func#6, error reporting for the bus concerned.  
func#7, add-on ROM init for all buses.  
func#8, BBS ROM init for all buses.  
Table 66 describes the lower nibble of the high byte and indicates the bus on which the routines  
are being executed.  
Table 66. Lower Nibble High Byte Functions  
Value  
0
Description  
Generic DIM (Device Initialization Manager)  
On-board System devices  
ISA devices  
EISA devices  
ISA PnP devices  
1
2
3
4
5
PCI devices  
111  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7. Connector Pin-Outs and Jumper Blocks  
7.1 Power Connectors  
The main power supply connection is obtained using the 24-pin connector (only the first 20 pins  
are populated when using an ATX12V power supply).  
12V CPU power is obtained using the 8-pin connector (only the first 4 pins are populated when  
using an ATX12V power supply).  
The following table defines the pin-outs of the connectors.  
Table 67. Power Connector Pin-out (J4J1)  
Pin  
Signal  
+3.3Vdc  
+3.3Vdc  
COM  
+5Vdc  
COM  
+5Vdc  
COM  
PWR_OK  
5VSB  
+12Vdc  
+12Vdc  
+3.3Vdc  
Color  
Orange  
Orange  
Black  
Pin  
Signal  
+3.3Vdc  
Color  
Orange  
Blue  
Black  
Green  
Black  
Black  
Black  
White  
Red  
1
2
3
4
5
6
7
8
9
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
-12Vdc  
COM  
Red  
Black  
PS_ON#  
COM  
Red  
COM  
Black  
COM  
Gray  
RSVD_(-5V)  
+5Vdc  
+5Vdc  
+5Vdc  
COM  
Purple  
Yellow  
Yellow  
Orange  
10  
11  
12  
Red  
Red  
Black  
Table 68. 12V CPU Power Connector (J9B1)  
Pin Signal  
Ground  
1
2
3
4
5
6
7
8
Ground  
Ground  
Ground  
+12V  
+12V  
Unused  
Unused  
NOTE  
The board will not boot if the 12V CPU power connector is not attached to the board.  
112  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
Table 69. Auxiliary Signal Connector (J5G2)  
Pin  
Signal  
SMB_SCLP  
SMB_SDAP  
PS_ALERT#  
GND  
1
2
3
4
5
3.3V  
7.2 PCI Bus Connectors  
Table 70. PCI Bus Connectors  
Pin  
A1  
Signal Name  
Ground (TRST#)  
(See Note)  
Pin  
B1  
Signal Name  
Pin  
Signal Name  
Pin Signal Name  
-12 V  
A32 AD16  
B32 AD17  
A2  
A3  
A4  
+12 V  
B2  
B3  
B4  
Ground (TCK)  
(See Note)  
Ground  
A33 +3.3 V  
A34 FRAME#  
A35 Ground  
B33 C/BE2#  
B34 Ground  
B35 IRDY#  
+5 V (TMS)  
(See Note)  
+5 V (TDI)  
Not connected (TDO)*  
(See Note)  
A5  
A6  
A7  
A8  
A92  
+5 V  
B5  
B6  
B7  
B8  
B9  
+5 V  
+5 V  
INTB#  
INTD#  
A36 TRDY#  
A37 Ground  
A38 STOP#  
A39 +3.3 V  
B36 +3.3 V  
B37 DEVSEL#  
B38 Ground  
B39 LOCK#  
B40 PERR#  
INTA#  
INTC#  
+5 V  
Reserved  
Not connected  
A40 SMBus Clock  
(PRSNT1#) (See Note)  
Line  
A10 +5 V (I/O)  
A11 Reserved  
B10 Reserved3  
A41 SMBus Data  
Line  
A42 Ground  
B41 +3.3 V  
B42 SERR#  
B11 Not connected  
(PRSNT2#) (See Note)  
A12 Ground  
A13 Ground  
A14 +3.3 V aux  
A15 RST#  
A16 +5 V (I/O)  
A17 GNT#  
A18 Ground  
A19 PME#  
A20 AD30  
B12 Ground  
B13 Ground  
B14 Reserved4  
B15 Ground  
B16 CLK  
B17 Ground  
B18 REQ#  
B19 +5 V (I/O)  
B20 AD31  
A43 PAR  
B43 +3.3 V  
B44 C/BE1#  
B45 AD14  
B46 Ground  
B47 AD12  
B48 AD10  
B49 Ground  
B50 Key  
A44 AD15  
A45 +3.3 V  
A46 AD13  
A47 AD11  
A48 Ground  
A49 AD09  
A50 Key  
A51 Key  
B51 Key  
A21 +3.3 V  
A22 AD28  
A23 AD26  
A24 Ground  
A25 AD24  
A26 IDSEL  
A27 +3.3 V  
B21 AD29  
B22 Ground  
B23 AD27  
A52 C/BE0#  
A53 +3.3 V  
A54 AD06  
A55 AD04  
A56 Ground  
A57 AD02  
A58 AD00  
B52 AD08  
B53 AD07  
B54 +3.3 V  
B55 AD05  
B56 AD03  
B57 Ground  
B58 AD01  
B24 AD25  
B25 +3.3 V  
B26 C/BE3#  
B27 AD23  
113  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
Pin  
Signal Name  
Pin  
Signal Name  
Pin  
Signal Name  
Pin Signal Name  
A28 AD22  
A29 AD20  
A30 Ground  
A31 AD18  
B28 Ground  
B29 AD21  
B30 AD19  
B31 +3.3 V  
A59 +5 V (I/O)  
A60 REQ64#  
A61 +5 V  
B59 +5 V (I/O)  
B60 ACK64#  
B61 +5 V  
B62 +5 V  
A62 +5 V  
Note:  
1. The signals (in parentheses) are optional in the PCI specification and are not currently implemented.  
2. On PCI Slot 6, A9 becomes P_REQ3#  
3. On PCI Slot 6, B10 becomes P_GNT3#  
4. On PCI Slot 6, B14 becomes CK_P_33M_S6 RISER  
7.3 Front Panel Connector  
A high density, 34-pin SSI header is provided to support a system front panel. The header  
contains reset, NMI, power control buttons, and LED indicators. The following table details the  
pin out of the header.  
Table 71. High-Density Front Panel 34-Pin Header Pin Out (J3J4)  
Pin  
Function  
Pin  
Function  
1
Power LED Anode  
Key  
2
5VSB  
5VSB  
3
4
5
7
Power LED Cathode  
VCC3  
6
8
COOL LED Cathode  
5VSB  
9
HDD Activity LED Cathode  
Power Switch  
GND  
Reset Switch  
GND  
ACPI Sleep Switch  
GND  
NMI Switch  
Key  
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
SYSTEM LED Cathode  
NIC#1 Activity LED Anode  
NIC#1 Activity LED Cathode  
RESUME I2C DATA  
RESUME I2C CLK  
Unused  
NIC#2 Activity LED Anode  
NIC#2 Activity LED Cathode  
Key  
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
5VSB  
5VSB  
ID LED Cathode  
ID Button Cathode  
GND  
SYS RDY LED Cathode  
VCC  
Unused  
114  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7.4 VGA Connector  
The following table details the pin out of the VGA connector.  
Table 72. VGA Connector Pin-out (J7A1)  
Pin  
1
2
3
4
5
Signal Name  
Red (analog color signal R)  
Green (analog color signal G)  
Blue (analog color signal B)  
No connection  
GND  
6
GND  
7
GND  
8
GND  
9
Fused VCC(+5V)  
GND  
No connection  
V_MONID1  
HSYNC (horizontal sync)  
VSYNC (vertical sync)  
V_MONID2  
10  
11  
12  
13  
14  
15  
7.5 NIC /USB Connector  
The Intel Server Board SE7210TP1-E supports two Magjack1* connectors (RJ45). The following  
table details the pin out of the connector.  
Table 73. Magjack Connector (RJ45, 10/100/1000) Pin Out (J6A2)  
Pin  
1
2
3
4
5
6
7
8
Signal Name  
LAN_V_1P8  
Pin  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Signal Name  
LAN_MDI_0*  
LAN_MDI_2*  
LAN_MDI_2  
LAN_MDI_1  
LAN_MDI_1*  
LAN_V_1P8  
LAN_V_1P8  
LAN_MDI_3  
LAN_MDI_3*  
LAN_MDI_0  
LAN_V_1P8  
LAN_LINK_100*  
LAN_LINK  
LAN_LINK_UP*  
LAN_ACTLED*  
GND  
9
GND  
115  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
Table 74. Magjack Connector (RJ45, 10/100) Pin Out (J5A1)  
Pin  
1
2
3
4
5
6
7
8
Signal Name  
Bypass cap to GND  
NIC2_MDI_MINUS2  
NIC2_MDI_PLUS2  
NIC2_RDP  
Pin  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Signal Name  
NIC2_TDN  
NIC2_TDP  
Bypass cap to GND  
NIC2_SPEED_LED*  
3.3V Stdby/LINK_1000*  
NIC2_LINK_LED#  
NIC2_ACT_LED#  
GND  
NIC2_RDN  
Bypass cap to GND  
Bypass cap to GND  
NIC2_MDI_PLUS3  
NIC2_MDI_MINUS3  
9
GND  
Table 75. Triple USB Pin Out (J9A2)  
Pin  
1
2
3
4
5
6
7
8
Signal Name  
USB_BACK_PWR1  
USB_BACK1_R#  
USB_BACK1_R  
GND  
Pin  
9
Signal Name  
USB_BACK_PWR3  
USB_BACK3_R#  
USB_BACK3_R  
GND  
10  
11  
12  
13  
14  
15  
16  
USB_BACK_PWR2  
USB_BACK2_R#  
USB_BACK2_R  
GND  
GND  
GND  
GND  
GND  
7.6 SATA/SATA RAID Connectors  
The SE7210TP1-E board provides two SATA/SATA RAID connectors. The pin out for both  
connectors is identical and is listed in the following table.  
Table 76. SATA 7-pin Connectors Pin Out (J3G1, J3G2)  
Pin  
Signal Name  
1
2
3
4
5
6
Ground  
TXP  
TXN  
Ground  
RXN  
RXP  
7, 8, 9  
Ground  
116  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7.7 6300ESB I/O IDE Connectors  
The SE7210TP1-E board provides two 40-pin, low-density 6300ESB I/O IDE connectors. The  
pin out for both connectors is identical and is listed in the following table.  
Table 77. 6300ESB I/O IDE 40-pin Connector Pin Out (J4J2, J4J3)  
Pin  
Signal Name  
Pin  
Signal Name  
1
Reset IDE  
Data 7  
2
Ground  
Data 8  
3
4
5
Data 6  
6
Data 9  
7
9
Data 5  
Data 4  
Data 3  
Data 2  
Data 1  
Data 0  
Ground  
DDRQ0 [DDRQ1]  
I/O Write#  
I/O Read#  
IOCHRDY  
DDACK0# [DDACK1#]  
IRQ 14 [IRQ 15]  
PDA1 (Address 1)  
8
Data 10  
Data 11  
Data 12  
Data 13  
Data 14  
Data 15  
Key  
Ground  
Ground  
Ground  
Ground  
Ground  
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
Not connected  
GPIO_DMA66_Detect_Pri  
(GPIO_DMA66_Detect_Sec)  
35  
37  
PDA0 (Address 0)  
36  
38  
PDA2 (Address 2)  
Chip Select 1P#  
Chip Select 3P#  
[Chip Select 1S#]  
[Chip Select 3S#]  
39  
HD_LED_PRI*/HD_LED_SEC* 40  
Ground  
7.8 Front Panel USB Header  
A header on the server board provides an option to support one additional USB connector. The  
pin out of the header is detailed in the following table.  
Table 78. Front Panel USB Connector Pin-out (J5G1)  
Pin  
Signal Name  
Pin  
Signal Name  
1
3
5
7
9
USB_FNT1_PWR  
2
USB_FNT1_PWR  
NC  
NC  
Ground  
Key  
4
6
8
10  
USB_FRONT1*  
USB_FRONT1  
Ground  
USB_ OC_FNT_R1  
Note: USB ports may be assigned as needed.  
117  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7.9 Floppy Connector  
The Intel Server Board SE7210TP1-E provides a 34-pin connector interface to the floppy drive  
controller. The following table details the pin out of the 34-pin floppy connector.  
Table 79. 34-pin Floppy Connector Pin Out (J3H1)  
Pin  
Signal Name  
Pin  
Signal Name  
1
3
5
7
9
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
GND  
Key  
2
DENSEL  
NC  
4
Key  
6
8
DRVDEN1  
FDINDX#  
MTR0# (Motor Enable A)  
NC  
DS0# (Drive Select A)  
NC  
DIR# (Stepper Motor Direction)  
STEP# (Step Pulse)  
WDATA# (Write Data)  
WGATE# (Write Enable)  
TRK0# (Track 0)  
WRTPRT# (Write Protect)  
RDATA# (Read Data)  
HDSEL# (Side 1 Select)  
DSKCHG# (Diskette Change)  
GND  
GND  
GND  
GND  
GND  
NC  
GND  
GND  
GND  
GND  
NC  
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
GND  
GND  
GND  
7.10 Serial Port Connector  
The Intel Server Board SE7210TP1-E has one 9-pin D-sub serial port connector and one 2 x 5  
serial port connector. The following tables detail the pin outs of these two ports.  
Table 80. 9-pin Serial A Port Pin Out (J8A1)  
Pin  
Signal Name  
1
DCD (Data Carrier Detect)  
2
3
4
5
6
7
8
9
RXD (Receive Data)  
TXD (Transmit Data)  
DTR (Data Terminal Ready)  
GND  
DSR (Data Set Ready)  
RTS (Request to Send)  
CTS (Clear to Send)  
RI (Ring Indicator)  
118  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
Table 81. 10-pin Header Serial B Port Pin Out (J8A2)  
Pin  
Signal Name  
1
DCD (Data Carrier Detect)  
2
3
4
5
DSR (Data Set Ready)  
RXD (Receive Data)  
RTS (Request to Send)  
TXD (Transmit Data)  
CTS (Clear to Send)  
6
7
DTR (Data Terminal Ready)  
8
RI (Ring indicator)  
9
10  
GND  
Key  
7.11 Keyboard and Mouse Connector  
PS/2 keyboard and mouse connectors are located on the back panel. The +5 V lines to these  
connectors are protected with a PolySwitch* circuit that, like a self-healing fuse, reestablishes  
the connection after an overcurrent condition is removed.  
NOTE  
The keyboard is supported in the bottom PS/2 connector and the mouse is supported in the top  
PS/2 connector. Power to the server should be turned off before a keyboard or mouse is  
connected or disconnected.  
The keyboard controller contains the AMI keyboard and mouse controller code, provides the  
keyboard and mouse control functions, and supports password protection for power-on/reset. A  
power-on/reset password can be specified in the BIOS Setup program.  
Table 82. Keyboard /Mouse PS/2 Connector Pin Out (J9A1)  
Connector Pin Signal Name  
Keyboard  
1
2
Data  
NC  
3
4
5
6
GND  
+5 V (Fused)  
Clock  
NC  
Mouse  
7
8
Data  
NC  
9
GND  
+5 V (Fused)  
Clock  
NC  
NC  
NC  
NC  
NC  
NC  
10  
11  
12  
13  
14  
15  
16  
17  
119  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7.12 Miscellaneous Headers  
7.12.1  
Fan Headers  
The Intel Server Board SE7210TP1-E provides seven 3-pin fan headers. All fans use direct 12  
volts. The six system fans and one processor fan are wired to the input of the Hardware  
Management (ADM1027 or ADT7463/SIO) and are monitored by Intel Server Management.  
Table 83. Three-Pin Fan Headers Pin-Out  
Pin  
Signal Name  
Type  
Description  
1
GND  
Power GROUND is the power supply ground  
2
FAN_FRONT1_PWR  
FAN_FRONT2_PWR  
FAN_REAR_PWR  
Fan Tach  
Power 12 V  
3
Out  
FAN_TACH signal is connected to the Hardware Management  
(ADM1027or ADT7463/ SIO) to monitor the fan speed  
7.13 System Recovery and Update Jumper  
CAUTION  
Do not move any jumpers with the power on. Always turn off the power and unplug the power cord  
from the server before changing a jumper setting. Otherwise, the board could be damaged.  
This 3-pin jumper block determines the BIOS Setup program mode. Table 84 describes the  
jumper settings for the two modes: normal and recovery.  
Table 84. BIOS Setup Configuration Jumper Settings (J1D1)  
Function/Mode  
Jumper Setting  
Configuration  
The BIOS uses current configuration information and passwords for  
booting.  
Normal Boot  
3
13-14  
1
Recovery  
The BIOS attempts to recover the BIOS configuration. A recovery  
diskette is required.  
3
14-15  
1
120  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
7.14 Clear CMOS Jumper  
CAUTION  
Do not move any jumpers with the power on. Always turn off the power and unplug the power  
cord from the server before changing a jumper setting. Otherwise, the board could be damaged.  
This 3-pin jumper block allows the user to clear CMOS. Table 85 describes the jumper settings  
for the two modes: normal and clear CMOS. When the jumper is set to Clear CMOS mode and  
the server is powered-up, the contents of the CMOS are cleared.  
Table 85. Clear CMOS Jumper Settings (J1D1)  
Function/Mode  
Jumper Setting  
Configuration  
Normal  
Normal Operation.  
3
1-2  
1
3
Clear CMOS  
Clears contents of CMOS area.  
2-3  
1
7.15 PASSWORD Jumper  
CAUTION  
Do not move any jumpers with the power on. Always turn off the power and unplug the power  
cord from the server before changing a jumper setting. Otherwise, the board could be damaged.  
This 3-pin jumper block allows the user to clear PASSWORD. Table 86 describes the jumper  
settings for the two modes: normal and clear PASSWORD. When the jumper is set to Clear  
PASSWORD mode and the server is powered-up, the contents of the PASSWORD are cleared.  
Table 86. PASSWORD Jumper Settings (J1D1)  
Function/Mode  
Jumper Setting  
Configuration  
Normal  
Normal Operation.  
5-6  
Clear  
Clears contents of PASSWORD area.  
PASSWORD  
6-7  
7.16 Write protected Jumper  
CAUTION  
Do not move any jumpers with the power on. Always turn off the power and unplug the power  
cord from the server before changing a jumper setting. Otherwise, the board could be damaged.  
121  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Connector Pin-Outs and Jumper Blocks  
This 3-pin jumper block allows the user to BIOS write protected. Table 89 describes the jumper  
settings for the two modes: normal and BIOS BOOT-BLOCK WRITE ENABLE. When the  
jumper is set to BIOS BOOT-BLOCK WRITE ENABLE mode and the server is powered-up, the  
BIOS update can be executed.  
Table 87. BIOS WRITE PROTECTED Jumper Settings (J1D1)  
Function/Mode  
WRITE  
Jumper Setting  
Configuration  
Normal Operation.  
PROTECTED  
9-10  
BIOS BOOT-  
BLOCK WRITE  
ENABLE  
BIOS BOOT-BLOCK WRITE ENABLE  
10-11  
122  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
8. Environmental Specifications  
8.1 Absolute Maximum Ratings  
Operating a Server Board SE7210TP1-E at conditions, beyond those shown in the following  
table, may cause permanent damage to the system. The table is provided for stress testing  
purposes only. Exposure to absolute maximum rating conditions for extended periods may  
affect system reliability.  
Table 88. Absolute Maximum Ratings  
Operating Temperature  
Storage Temperature  
5 degrees C to 50 degrees C 1  
-55 degrees C to +150 degrees C  
-0.3 V to Vdd + 0.3V 2  
-0.3 V to 3.63 V  
Voltage on any signal with respect to ground  
3.3 V Supply Voltage with Respect to ground  
5 V Supply Voltage with Respect to ground  
-0.3 V to 5.5 V  
Notes:  
1. Chassis design must provide proper airflow to avoid exceeding the Intel® Pentium® 4 processor  
maximum case temperature.  
2. VDD means supply voltage for the device.  
8.2 SE7210TP1-E Power Budget  
The following table shows the power consumed on each supply line for an Intel Server  
Board SE7210TP1-E that is configured with one Intel Pentium 4 processor (pulling max  
current), all PCI slots full and pulling max amount of current, memory completely full, USB  
pulling max current, and fans assuming max current. The numbers provided in the table  
should be used for reference purposes only. Different hardware configurations will produce  
different numbers. The numbers in the table reflect a common usage model operating at  
higher-than-average stress levels.  
Table 89. SE7210TP1-E Power Budget  
Device(s)  
Processors  
Memory DIMMs  
Server board  
Fans  
3.3V  
+5V  
+12V  
-12V  
5V Standby  
0
0
0
10.73  
10.44  
4.633  
0
0
4.96  
0
0.25  
0.8  
0
0.1  
1.8  
Keyboard/Mouse  
0
0.14  
PCI slots  
13.65  
3
0.5  
Total Current  
Total Power  
18.61  
61.413  
18.213  
91.065  
12.28  
147.36  
0.1  
1.2  
1.8  
9
Total  
310.038  
123  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
8.3 Product Regulatory Compliance  
8.3.1  
Product Safety Compliance  
The SE7210TP1-E complies with the following safety requirements:  
UL 1950 - CSA 950 (US/Canada)  
EN 60 950 (European Union)  
IEC60 950 (International)  
CE – Low Voltage Directive (73/23/EEC) (European Union)  
EMKO-TSE (74-SEC) 207/94 (Nordics)  
GOST R 50377-92 (Russia)  
8.3.2  
Product EMC Compliance  
The SE7210TP1-E has been has been tested and verified to comply with the following  
electromagnetic compatibility (EMC) regulations when installed in a compatible Intel host  
system. For information on compatible host system(s), contact your local Intel representative.  
FCC (Class A Verification) – Radiated & Conducted Emissions (USA)  
ICES-003 (Class A) – Radiated & Conducted Emissions (Canada)  
CISPR 22, 3rd Edition (Class A) – Radiated & Conducted Emissions (International)  
EN55022 (Class A) – Radiated & Conducted Emissions (European Union)  
EN55024 (Immunity) (European Union)  
CE – EMC Directive (89/336/EEC) (European Union)  
VCCI (Class A) – Radiated & Conducted Emissions (Japan)  
AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand)  
RRL (Class A) Radiated & Conducted Emissions (Korea)  
BSMI CNS13438 (Class A) Radiated & Conducted Emissions (Taiwan)  
GOST R 29216-91 (Class A) Radiated & Conducted Emissions (Russia)  
GOST R 50628-95 (Immunity) (Russia)  
124  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
8.3.3  
Product Regulatory Compliance Markings  
This product is provided with the following product certification markings:  
Product Certification Markings  
UL Recognition Mark  
CE Mark  
Russian GOST Mark  
Australian C-Tick Mark  
BSMI DOC Marking  
BSMI EMC Warning  
RRL MIC Mark  
8.4 Electromagnetic Compatibility Notices  
8.4.1  
FCC (USA)  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept  
any interference received, including interference that may cause undesired operation.  
For questions related to the EMC performance of this product, contact:  
Intel Corporation  
5200 N.E. Elam Young Parkway  
Hillsboro, OR 97124  
1-800-628-8686  
125  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be determined by turning  
the equipment off and on, the user is encouraged to try to correct the interference by one or  
more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment to an outlet on a circuit other than the one to which the receiver  
is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Any changes or modifications not expressly approved by the grantee of this device could void  
the user’s authority to operate the equipment. The customer is responsible for ensuring  
compliance of the modified product.  
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC  
Class A or B limits may be attached to this server product. Operation with noncompliant  
peripherals is likely to result in interference to radio and TV reception.  
All cables used to connect to peripherals must be shielded and grounded. Operation with  
cables, connected to peripherals that are not shielded and grounded may result in interference  
to radio and TV reception.  
8.4.2  
INDUSTRY CANADA (ICES-003)  
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital  
apparatus set out in the interference-causing equipment standard entitled: “Digital Apparatus,”  
ICES-003 of the Canadian Department of Communications.  
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils  
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Apparelis  
Numériques”, NMB-003 édictee par le Ministre Canadian des Communications.  
8.4.3  
Europe (CE Declaration of Conformity)  
This product has been tested in accordance to, and complies with the Low Voltage Directive  
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark  
to illustrate its compliance.  
8.4.4  
Taiwan Declaration of Conformity  
This product has been tested and complies with CNS13438. The product has been marked with  
the BSMI DOC mark to illustrate compliance.  
126  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
8.4.5  
Korean RRL Compliance  
This product has been tested and complies with MIC Notices No. 1997-41 and 1997-42. The  
product has been marked with the MIC logo to illustrate compliance.  
The English translation for the above is as follows:  
1. Type of Equipment (Model Name): SE7210TP1-E  
2. Certification No.: Contact Intel Representative  
3. Name of Certification Recipient: Intel  
4. Date of Manufacturer: Marked on Product  
5. Manufacturer / Nation : Intel  
8.4.6  
Australia / New Zealand  
This product has been tested and complies with AS/NZS 3548. The product has been marked  
with the C-Tick mark to illustrate compliance.  
8.5 Replacing the Back-Up Battery  
The lithium battery on the server board powers the RTC for up to 10 years in the absence of  
power. When the battery starts to weaken, it loses voltage, and the server settings stored in  
CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer  
service representative or dealer for a list of approved devices.  
WARNING  
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent  
type recommended by the equipment manufacturer. Discard used batteries according to  
manufacturer’s instructions.  
ADVARSEL!  
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af  
samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.  
ADVARSEL  
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av  
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.  
VARNING  
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som  
rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.  
127  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
VAROITUS  
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan  
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.  
8.6 Calculated Mean Time Between Failures (MTBF)  
The MTBF (Mean Time Between Failures) for the Intel Server Board SE7210TP1-E as  
configured from the factory is shown in the table below.  
Product Code  
Calculated MTBF  
Operating Temperature  
55 degrees C  
SE7210TP1  
110,894 hours  
SE7210TP1SCSI 103,568 hours  
55 degrees C  
128  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Environmental Specifications  
8.7 Mechanical Specifications  
The following figure shows the Intel Server Board SE7210TP1-E general-purpose chassis I/O  
shield mechanical drawing. If the Intel Server Board SE7210TP1-E is used in a 1U chassis, the  
user will need to obtain the I/O shield directly from the chassis vendor.  
Figure 14. Intel Server Board SE7210TP1-E I/O Shield Drawing  
129  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Appendix A: Glossary of Terms  
Appendix A: Glossary of Terms  
This appendix contains important terms used in the preceding chapters. For ease of use,  
numeric entries are listed first (e.g., “82460GX”) with alpha entries following (e.g., “AGP 4x”).  
Acronyms are then entered in their respective place, with non-acronyms following.  
Term  
Definition  
Advanced Configuration and Power Interface  
ACPI  
ASIC  
BIOS  
Byte  
Application Specific Integrated Circuit  
Basic input/output system  
8-bit quantity.  
CMOS  
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128  
bytes of memory, which normally resides on the server board.  
DCD  
DMA  
ECC  
EMC  
EPS  
ESCD  
FDC  
FIFO  
FRU  
GB  
Data Carrier Detect  
Direct Memory Access  
Error Correcting Code  
Electromagnetic Compatibility  
External Product Specification  
Extended System Configuration Data  
Floppy Disk Controller  
First-In, First-Out  
Field replaceable unit  
1024 MB.  
GPIO  
GUID  
Hz  
General purpose I/O  
Globally Unique ID  
Hertz (1 cycle/second)  
Hardware Design Guide  
Inter-integrated circuit bus  
Intel® architecture  
Interrupt Request  
In-target probe  
HDG  
2
I C  
IA  
IRQ  
ITP  
KB  
1024 bytes  
LAN  
LBA  
LCD  
LPC  
MB  
Local area network  
Logical Block Address  
Liquid crystal display  
Low pin count  
1024 KB  
MBE  
Ms  
Multi-Bit Error  
milliseconds  
MTBF  
NIC  
NMI  
OEM  
PBGA  
PERR  
Mean Time Between Failures  
Network Interface Card  
Non-maskable Interrupt  
Original equipment manufacturer  
Pin Ball Grid Array  
Parity Error  
130  
Revision 2.0  
Intel® Server Board SE7210TP1-E TPS  
Term  
Appendix A: Glossary of Terms  
Definition  
PIO  
PME  
PnP  
Programmable I/O  
Power Management Event  
Plug and Play  
POST  
PWM  
RAM  
RI  
Power-on Self Test  
Pulse-Width Modulator  
Random Access Memory  
Ring Indicate  
ROM  
RTC  
SBE  
SCI  
SDR  
SDRAM  
SEL  
Read Only Memory  
Real Time Clock  
Single-Bit Error  
System Configuration Interrupt  
Sensor Data Record  
Synchronous Dynamic RAM  
System event log  
SERR  
SM  
System Error  
Server Management  
SMI  
Server management interrupt. SMI is the highest priority nonmaskable interrupt  
System Management Mode  
System Management Software  
Serial Presence Detect  
Server Standards Infrastructure  
Technical Product Specification  
Universal asynchronous receiver and transmitter  
Universal Serial Bus  
SMM  
SMS  
SPD  
SSI  
TPS  
UART  
USB  
VGA  
VRM  
Word  
Video Graphic Adapter  
Voltage Regulator Module  
16-bit quantity  
131  
Revision 2.0  

相关型号:

SE7221BA1-E

Tested Hardware and Operating System List
INTEL

SE7230CA1-E

Entry Server Board
INTEL

SE7261A

2.5-2.7 GHz WiMAX Front End Module Preliminary
SIGE

SE7261A-EK1

2.5-2.7 GHz WiMAX Front End Module Preliminary
SIGE

SE7261A-R

2.5-2.7 GHz WiMAX Front End Module Preliminary
SIGE

SE7262L

2.5-2.7 GHz WiMAX Power Amplifier
SIGE

SE7262L-EK1

2.5-2.7 GHz WiMAX Power Amplifier
SIGE

SE7262L-R

2.5-2.7 GHz WiMAX Power Amplifier
SIGE

SE7265L

2.3-2.7 GHz WiMAX Power Amplifier Preliminary
SIGE

SE7265L-EK1

2.3-2.7 GHz WiMAX Power Amplifier Preliminary
SIGE

SE7265L-R

2.3-2.7 GHz WiMAX Power Amplifier Preliminary
SIGE

SE7351L

3.3-3.8 GHz Front-End Transceiver
SIGE