DATASHEET
Dual Channel/Dual Phase PMBus™ ChargeMode™
Control DC/DC Digital Controller
ZL8800
Features
The ZL8800 is a dual output or dual phase digital DC/DC
controller. Each output can operate independently or be used
together in a dual phase configuration for high current
applications.
• Unique compensation-free design – always stable
• Output voltage range: 0.54V to 5.5V
• Input voltage range: 4.5V to 14V
• 1% Output Voltage accuracy over line, load and temperature
The ZL8800 supports a wide range of output voltages
(0.54V to 5.5V) operating from input voltages as low as 4.5V
up to 14V.
• ChargeMode control achieves fast transient response,
reduced output capacitance and provides output stability
without compensation.
With the fully digital ChargeMode™ Control the ZL8800 will
respond to a transient load step within a single switching cycle.
This unique compensation-free modulation technique allows
designs to meet transient specifications with minimum output
capacitance thus saving cost and board space.
• Switching frequency range 200kHz to 1.33MHz
• Proprietary single wire DDC (Digital-DC) serial bus enables
voltage sequencing and fault spreading with other Intersil
ICs
• Tracking of an external power supply
Intersil’s proprietary single wire DDC (Digital-DC™) serial bus
enables the ZL8800 to communicate between other Intersil
ICs. By using the DDC, the ZL8800 achieves complex functions
such as inter-IC phase current balancing, sequencing and fault
spreading, eliminating complicated power supply managers
with numerous external discrete components.
• Cycle-by-cycle inductor peak current protection
• Digital fault protection for output voltage UV/OV, input
voltage UV/OV, temperature and MOSFET driver voltage
• 10-bit average output current measurement with adjustable
gain settings for sensing with high current, low DCR
inductors
The ZL8800 features cycle-by-cycle output overcurrent
protection. The input voltage, output voltages and
DrMOS/MOSFET driver supply voltages are overvoltage and
overvoltage protected. Two external and one internal
temperature sensor are available for temperature monitoring,
one of which is used for under and over-temperature
protection. A snapshot parametric capture feature allows
users to take a snapshot of operating and fault data during
normal or fault conditions.
• 10-bit monitor ADC measures input voltage, input current,
output voltage, internal, external temperature, driver voltage
• Configurable to use stand-alone MOSFET drivers or
integrated Driver-MOSFET (DrMOS) devices
• Nonvolatile memory for storing operating parameters and
fault events.
• PMBus™ compliant
Integrated Low Dropout (LDO) regulators allow the ZL8800 to
be operated from a single input supply eliminating the need
for additional linear regulators. The LDO output can be used to
power external drivers or DrMOS devices.
Applications
• Servers/storage equipment
• Telecom/datacom equipment
• Power supplies (memory, DSP, ASIC, FPGA)
With full PMBus™ compliance the ZL8800 is capable of
measuring and reporting input voltage, input current, output
voltage, output current as well as the device’s internal
temperature, 2 external temperatures and an auxiliary voltage
input.
Related Literature
• AN1877, “ZL8800-2CH-DEMO1Z Demonstration Board User
Guide”
• AN1900, “USB to PMBus™ Adapter User Guide”
• AN1901, “ZL8800-2PH-DEMO1Z Demonstration Board”
TABLE 1. KEY DIFFERENCES BETWEEN FAMILY OF PARTS
PART NUMBER
ZL8800
DUAL OUTPUT
DUAL PHASE
DDC CURRENT SHARE
SPS SUPPORT
Yes
No
Yes
Yes
Yes
No
Yes
Yes
No
No
ZL8801
ZL8802
Yes
Yes
September 14, 2015
FN7558.3
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1
1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2013, 2015. All Rights Reserved
Intersil (and design), Digital-DC and ChargeMode are trademarks owned by Intersil Corporation or one of its subsidiaries.
All other trademarks mentioned are the property of their respective owners.
ZL8800
Table of Contents
Simplified Two Output Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Pin Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pin Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Absolute Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermal Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ZL8800 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Digital-DC Architecture Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Power Management Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Multimode Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Configurable Pins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SMBus Device Address Selection (SA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Output Voltage and VOUT_MAX Selection (VSET0,1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Switching Frequency Setting (SYNC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Input Voltage Undervoltage Lockout Setting (UVLO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Internal Bias Regulators and Input Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Start-up Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ton Delay and Rise Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power-Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power Management Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Output Overvoltage Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Output Prebias Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Output Overcurrent Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Current Limit Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Input Current Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Thermal Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Voltage Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Voltage Margining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
External Voltage Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SMBus Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Digital-DC™ Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Phase Spreading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Output Sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Fault Spreading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Active Current Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Temperature Monitoring Using XTEMP Pin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Nonvolatile Memory and Security Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DC/DC Converter Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Power Train Component Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Monitoring via SMBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
PMBus™ Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
PMBus™ Data Formats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
PMBus™ Command Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Firmware Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Revision History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
About Intersil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Package Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
FN7558.3
September 14, 2015
Submit Document Feedback
2
ZL8800
Simplified Two Output Application
VIN
4.5V TO 14V
VDD
VDRV
VDRV
ZL8800
VOUT1
0.54V TO 5.5V
VDD
VOUT0
0.54V TO 5.5V
VDD
GH
BST
GL
GH
BST
GL
PWMH1
PWMH0
PWML0
PWML1
ISENA1
ISENB1
ISENA0
ISENB0
VSENP1
VSENN1
VSENP0
VSENN0
INTER-DEVICE
COMMUNICATION
DDC
EN0
EN1
CONTROL AND
STATUS
SDA
PG0
PG1
SCL
SALRT
PMBus™
GND
FIGURE 1. SIMPLIFIED TWO OUTPUT APPLICATION
FN7558.3
September 14, 2015
Submit Document Feedback
3
ZL8800
Block Diagram
PWMH0
PWML0
ASCR
DIGITAL PWM
MODULATOR
PWM+
DEAD
TIME
ADC
ADC
VSEN0P/N
PWMH1
PWML1
ASCR
DIGITAL PWM
MODULATOR
PWM+
DEAD
TIME
VSEN1P/N
XTEMP1P/N
XTEMP0P/N
MONITOR
ADC
MGN0/1
EN0/1
VTRKP/N
DIGITAL LOGIC
+
OV/UV/OC/UC
COMPARATORS
VMON
VDD
PG0/1
OSC
ISENA0
CLK
GEN
I
/
PEAK
PLL
SYNC
DDC
IAVG
ADC
ISENB0
ISENA1
DIGITAL-DC
INTER-DEVICE
COMMUNICATIONS
MICROCONTROLLER
AND
NONVOLATILE
MEMORY
I
/
PEAK
IAVG
ADC
ISENB1
SDA
IIN
ADC
I2C AND SMBus
SERIAL
SCL
INTERFACE
SALRT
PIN-STRAP
RESISTOR
DETECTION
LDOs
VDD
GAIN
FIGURE 2. BLOCK DIAGRAM
FN7558.3
September 14, 2015
Submit Document Feedback
4
Schematic
C11
1µF
VIN
10V TO 14V
VDD
VDRV
VDRV
VMON
C1
22µF
C10
1µF
C2
22µF
C5
10µF
C9
1µF
R1
100k
VOUT1
1.0V
VDD
U3
Q3
GH
SW
L2
R2
6.65k
VDD
U2
VOUT0
1.2V
Q1
GH
SW
230nH
L1
COUT4
COUT3
4x100µF
HSEL PWMH
ZL1505
PWMH1
PWML1
C13
0.1µF
2x680µF
230nH
COUT1
COUT2
PWMH0
PWML0
BST
PWMH HSEL
ZL1505
PWML
R4
1.3k
C12
0.1µF
4x100µF
2x680µF
GL
LSEL
Q4
PWML
LSEL
BST
GL
R3
U1
ZL8800
1.3k
C4
0.68µF
Q2
ISENA1
C3
0.68µF
ISENB1
VSEN1N
VSEN1P
VR6
ISENA0
ISENB0
V25
VR5
VSEN0N
VSEN0P
C6
10µF
C7
10µF
C8
10µF
R9
10k
VSET1
VSET0
SA
DDC
DDC
SYNC
SYNC
UVLO
CONTROL
AND
STATUS
EN(0,1)
PG(0,1)
R5
R6
21.5k
R7
36.1k
R8
21.5k
SALRT
SDA
61.9k
PMBus™
SCL
SGND
DGND
FIGURE 3. SCHEMATIC
ZL8800
Pin Configuration
ZL8800
(44 LD QFN)
TOP VIEW
33
32
31
30
29
28
27
26
25
24
23
VDD
1
2
3
4
5
6
7
8
9
SCL
SDA
VR5
VR6
SALRT
SGND
VDRV
ISENA1
ISENB1
PWML1
PWMH1
PWMH0
PWML0
ISENB0
SA
VMON
DGND
Exposed Paddle
Connect to SGND
MGN0
MGN1
VSET0 10
VSET1
11
Pin Description
TYPE
PIN
1
LABEL
SCL
(Note 1)
I/O
DESCRIPTION
Serial clock. Connect to external host and/or to other ZL devices.
Serial data. Connect to external host and/or to other ZL devices.
Serial alert. Connect to external host if desired.
2
SDA
I/O
3
SALRT
SGND
O
Connect to low impedance ground plane. Internal connection to SGND.
4
PWR
Serial address select pin. Used to assign unique address for each individual device or to enable certain management
features.
5
6
SA
M
I
External voltage monitoring (can be used for external driver bias (VDRV) monitoring). Requires an external 16:1 resistor
divider network.
VMON
Digital ground. Connect to low impedance ground plane.
Channel 0 margin pin.
7
DGND
MGN0
MGN1
VSET0
VSET1
PG0
PWR
8
I
I
Channel 1 margin pin.
9
Channel 0 output voltage selection pin. Used to set V
Channel 1 output voltage selection pin. Used to set V
Channel 0 power-good output.
and V
and V
max.
max.
10
11
12
13
14
M
M
O
OUT0
OUT0
OUT1
OUT1
Undervoltage lockout selection. Sets the minimum value for V voltage to enable V
DD
.
UVLO
DDC
M
I/O
I
OUT
Single wire DDC bus (Current sharing, inter device communication).
External temperature sensor input for channel 0. Connect to external 2N3904 (Base Emitter junction) or equivalent
embedded thermal diode.
15 XTEMP0P
16 XTEMP0N
External temperature sensor input for channel 0 return
I
I
I
I
Tracking sense positive input. Used to track an external voltage source.
Tracking sense negative input (return).
17
18
19
VTRKP
VTRKN
VSEN0P
Differential output channel 0 voltage sense feedback. Connect to positive output regulation point.
FN7558.3
September 14, 2015
Submit Document Feedback
6
ZL8800
Pin Description (Continued)
TYPE
PIN
20
LABEL
(Note 1)
DESCRIPTION
Differential output channel 0 voltage sense feedback. Connect to negative output regulation point.
VDRV (MOSFET driver bias supply) Enable. Leave unconnected (float) or pull-up to VR5 to enable, tie to ground to disable.
Positive differential voltage input for channel 0 DCR current sensing.
Negative differential voltage input for channel 0 DCR current sensing.
PWM0 low signal/DrMOS enable.
VSEN0N
I
21 VDRVEN
I
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
ISENA0
ISENB0
PWML0
PWMH0
PWMH1
PWML1
ISENB1
ISENA1
VDRV
I
I
O
PWM0 high signal.
O
PWM1 high signal.
O
PWM1 low signal/DrMOS enable.
O
Negative differential voltage input for channel 1 DCR current sensing.
Positive differential voltage input for channel 1 DCR current sensing.
MOSFET driver bias supply regulator output.
I
I
PWR
Internal 6V reference used to power internal circuitry.
Internal 5V reference used to power internal circuitry.
Supply voltage.
VR6
PWR
VR5
PWR
VDD
PWR
Input current monitor negative input.
IINN
I
Input current monitor positive input.
IINP
I
Internal 2.5V reference used to power internal circuitry.
Channel 1 power-good output.
V25
PWR
PG1
O
I
Differential output channel 1 voltage sense feedback. Connect to negative output regulation point.
Differential output channel 1 voltage sense feedback. Connect to positive output regulation point.
External temperature sensor input for channel 1 return.
VSEN1N
VSEN1P
I
40 XTEMP1N
41 XTEMP1P
I
External temperature sensor input for channel 1. Connect to external 2N3904 (base emitter junction) or equivalent
embedded thermal diode.
I
Enable channel 0. Active signal enables PWM0 switching.
Enable channel 1. Active signal enables PWM1 switching.
42
43
EN0
EN1
I
I
Clock synchronization input. Used to set the frequency of the internal clock, to sync to an external clock or to output internal
clock.
44
SYNC
SGND
M/I/O
PWR
Exposed thermal pad. Connect to low impedance ground plane. Internal connection to SGND.
PAD
NOTE:
1. I = Input, O = Output, PWR = Power or Ground, M = Multimode pins.
FN7558.3
September 14, 2015
Submit Document Feedback
7
ZL8800
Ordering Information
FIRMWARE
REVISION
(Note 5)
PART
NUMBER
(Notes 2, 3, 4)
TEMP. RANGE
(°C)
PACK
METHOD
PACKAGE
(RoHS Compliant)
PART
MARKING
PKG.
DWG. #
ZL8800ALAFTK
8800
8800
8800
8800
1.04
1.04
1.06
1.06
-40 to +85
-40 to +85
-40 to +85
-40 to +85
Tape and Reel 1k
Tape and Reel 4k
Tape and Reel 4k
Tape and Reel 1k
44 Lead QFN
44 Lead QFN
44 Lead QFN
44 Lead QFN
L44.7x7B
L44.7x7B
L44.7x7B
L44.7x7B
ZL8800ALAFT
ZL8800ALBFT
ZL8800ALBFTK
ZL8800-2CH-DEMO1Z Demonstration Board, 2 independent 30A synchronous buck converters with compensation-free ChargeMode control
ZL8800-2PH-DEMO1Z Demonstration Board, 2-phase 60A synchronous buck converter with compensation-free ChargeMode control
NOTES:
2. Please refer to TB347 for details on reel specifications.
3. These Intersil Pb-free plastic packaged products employ special Pb-free material sets, molding compounds/die attach materials, and 100% matte
tin plate plus anneal (e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations). Intersil
Pb-free products are MSL classified at Pbfree peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020.
4. For Moisture Sensitivity Level (MSL), please see device information page for ZL8800 For more information on MSL please see techbrief TB363.
5. See “Firmware Revision History” on page 83; only the latest firmware revision is recommended for new designs.
ZL8800
A L A F T
Product Designator
Shipping Option
T = Tape and Reel - 4000 pcs
TK = Tape and Reel - 1000 pcs
Contact factory for other options
Lead Finish
F = Lead-free matte tin
Firmware Revision (Alpha character)
A: 1.04
B: 1.06
Operating Temperature Range
L = -40°C to +85°C
Package Designator
A = QFN package
FN7558.3
September 14, 2015
Submit Document Feedback
8
ZL8800
Absolute Maximum Ratings
Thermal Information
DC Supply Voltage: VDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 17V
Logic I/O Voltage: DDC, EN0, EN1, MGN0, MGN1, PG0,
Thermal Resistance (Typical)
44 Ld QFN Package (Notes 7, 8) . . . . . . . .
(°C/W)
25
(°C/W)
1.5
JA
JC
PG1, SA, VDRVEN, SALRT, SCL, SDA, SYNC, UVLO,
VMON, VSET0, VSET1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.0V
Analog Input Voltages: VSEN0P, VSEN0N, VSEN1P, VSEN1N,
Storage Temperature range . . . . . . . . . . . . . . . . . . . . . . . .-55°C to +150°C
Pb-free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
VTRKP, VTRKN, ISENA0, ISENA1, ISENB0, ISENB1 . . . . . . -0.3V to 6.5V
XTEMP0P, XTEMP1P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.0V
XTEMP0N, XTEMP1N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 0.3V
IINN, IINP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 17V
Logic Reference: V25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 3V
Bias Supplies: VR5, VR6, VDRV. . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6.5V
PWM Logic OUTPUTS, PWMH0, PWMH1, PWML0, PWML1 . . .-0.3V to 6.5V
Ground Voltage Differential (VDGND-VSGND), . . . . . . . . . . . . . . .-0.3V to +0.3V
ESD Ratings
Recommended Operating Conditions
Input Supply Voltage Range, VDD . . . . . . . . . . . . . . . . . . . . . . . 4.5V to 14V
Output Voltage Range, VOUT. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.54V to 5.5V
Operating Junction Temperature Range, T . . . . . . . . . . . .-40°C to +125°C
J
Ambient Temperature Range, T . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
A
5V (VR5) Supply Total Supplied Current (Note 9) . . . . . . . . . . . . . . . . . 5mA
5V LDO Supply (VDRV) (Note 6) . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 80mA
Human Body Model (Tested per JESD22-A114E) . . . . . . . . . . . . . . 3000V
Machine Model (Tested per JESD22-A115-A) . . . . . . . . . . . . . . . . . . 200V
Charged Device Model (Tested per JESD22-C1010-D) . . . . . . . . . . 1000V
Latch-up (Tested per JESD78C; Class 2, Level A) . . . . . . . . . . . . . . . 100mA
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
6. Output current is limited by device thermal dissipation.
7. is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See Tech
JA
Brief TB379.
8. For , the “case temp” location is the center of the exposed metal pad on the package underside.
JC
9. Total of current used by pull-ups to SDA, SCL, SALRT, DDC, EN, PG (including push-pull configuration).
Electrical Specifications
V
= 12V. Typical values are at T = +25°C. Boldface limits apply across the operating ambient temperature
DD A
range, T -40°C to +85°C
A
MIN
MAX
PARAMETER
TEST CONDITIONS
(Note 15)
TYP
(Note 15)
UNIT
IC INPUT AND BIAS SUPPLY CHARACTERISTICS
IDD Supply Current
f
f
= 200kHz
-
-
26
50
50
80
mA
mA
mA
V
SW
= 1.33MHz
SW
IDD Device Disabled Current
EN = 0V, SMBus inactive, V = 12V, f
DD SW
= 400kHz
-
20
30
VR5 Reference Output Voltage
V25 Reference Output Voltage
VR6 Reference Output Voltage
VDRV 5V Output Voltage (Note 10)
OUTPUT CHARACTERISTICS
V
> 6V, I < 5mA
4.5
2.25
5.5
4.5
5.0
2.5
6.1
5.25
5.5
2.75
6.6
5.5
DD
For Reference only, VR > 3V
For Reference only, V = 12V
V
V
DD
V
> 6.0V; 0-80mA
V
DD
Output Voltage Adjustment Range
Output Voltage Set-point Accuracy (Note 12)
V
> V
OUT
+ 1.8V
0.54
-1
-
-
5.5
1
V
IN
Across line, load, temperature variation
0.72 < V < 5.50
% V
OUT
OUT
Output Voltage Set-point Resolution (Note 11)
Output Voltage Positive Sensing Bias Current
Output Voltage Negative Sensing Bias Current
LOGIC INPUT/OUTPUT CHARACTERISTICS
Logic Input Leakage Current
Set using PMBus™ command
VSEN[0,1] P = 4V (negative = sinking)
VSEN[0,1] N = 0V
-
-100
-
±0.025
20
-
100
-
% V
OUT
µA
20
µA
Logic I/O - Multimode Pins
-100
-
-
-
-
-
100
0.8
-
nA
V
Logic Input Low, V
-
IL
Logic Input High, V
2
-
V
IH
Logic Output Low, V
2mA sinking
0.5
-
V
OL
Logic Output High, V
2mA sourcing
2.25
V
OH
FN7558.3
September 14, 2015
Submit Document Feedback
9
ZL8800
Electrical Specifications
V
= 12V. Typical values are at T = +25°C. Boldface limits apply across the operating ambient temperature
A
DD
range, T -40°C to +85°C (Continued)
A
MIN
MAX
PARAMETER
PWM INPUT/OUTPUT CHARACTERISTICS
PWM Output Low
TEST CONDITIONS
(Note 15)
TYP
(Note 15)
UNIT
2mA sinking
2mA sourcing
Vpwm = 2.5V
-
4.25
-
-
-
-
0.5
-
V
V
PWM Output High
PWM Tri-state Input Bias Current (PWMH0,1)
OSCILLATOR AND SWITCHING CHARACTERISTICS
Switching Frequency Range
10
µA
200
-5
-
-
-
-
-
1334
5
kHz
%
Switching Frequency Set-point Accuracy
Minimum SYNC Pulse Width
50% to 50%
150
-10
100
-
ns
Input Clock Frequency Drift Tolerance
PMBus™ Clock Frequency (Note 13)
Maximum allowed drift of external clock
10
400
%
kHz
POWER MANAGEMENT
SOFT-START/ RAMP CHARACTERISTICS
Ton Delay/Toff Delay
Factory default
-
5
-
ms
ms
ms
ms
ms
µs
Ton Delay/Toff Delay Range
Set using PMBus™ command
Turn-on, turn-off delay
Factory default
2
5000
Ramp Delay/Toff Delay Accuracy
Soft-start/Ton Ramp/Toff Ramp Duration
Soft-start/Ton Ramp/Toff Ramp Duration Range
Soft-start/Ton Ramp/Toff Ramp Duration Accuracy
TRACKING
-
-0/+2
5
-
-
0.5
-
-
100
-
Set using PMBus™ command
±250
VTRK Input Bias Current
VTRK = 5V
-
70
-
200
2
µA
15
VTRK Regulation Accuracy
100% tracking, V
– VTRK
-2
% V
OUT
OUT
POWER-GOOD
Power-good V
Power-good V
Threshold
Hysteresis
Factory default
Factory default
Factory default
-
-
90
5
-
% V
OUT
OUT
-
%
OUT
Power-good Delay
Applies to turn-on only (LOW to HIGH transition)
-
1
-
ms
ms
Set using PMBus™ command
0
-
5000
MONITORING AND FAULT MANAGEMENT
INPUT VOLTAGE MONITOR AND FAULT DETECTION
VDD/VIN UVLO Threshold Range
VDD/VIN Monitor Accuracy
2.85
-
16
V
Full Scale (FS) = 14V
Full Scale (FS) = 14V
-
-
-
±2
-
-
-
%FS
%FS
µs
VDD/VIN Monitor Resolution
±0.15
100
VIN UV/OV Fault Response delay
INPUT CURRENT
Input Current Sense Differential Input Voltage
Input Current Sense Input Offset Voltage
Input Current Sense Accuracy
V
-V
IINP IINN
0
-
-
20
mV
µV
V -V
IINP IINN
±100
±5
-
-
% of full scale (20mV)
-
% FS
OUTPUT VOLTAGE MONITOR AND FAULT DETECTION
VOUT Monitor Accuracy
FS = Vset voltage (Vo)
FS = Vset voltage (Vo)
-2
-
2
-
%FS
%FS
µs
VOUT Monitor Resolution
-
-
± 0.15
10
VOUT UV/OV Fault Response Delay
-
FN7558.3
September 14, 2015
Submit Document Feedback
10
ZL8800
Electrical Specifications
V
= 12V. Typical values are at T = +25°C. Boldface limits apply across the operating ambient temperature
A
DD
range, T -40°C to +85°C (Continued)
A
MIN
MAX
PARAMETER
TEST CONDITIONS
OUTPUT CURRENT
(Note 15)
TYP
(Note 15)
UNIT
OUTPUT CURRENT SENSE RESOLUTION
Low Range
±25mV full scale
-
-
-
37.5
56.25
75.0
-
-
-
µV
µV
µV
Medium Range
± 35mV full scale
±50mV full scale
High Range
OUTPUT CURRENT SENSE INPUT BIAS CURRENT
VOUT Referenced
ISENA0 or ISENA1
ISENB0 or ISENB1
-100
-25
-
-
100
25
nA
µA
OUTPUT CURRENT SENSE MONITOR AND FAULT DETECTION
Output Current DCR Monitor Temperature
Compensation
Factory default
3900
ppm/°C
Configurable via PMBus™
100
12700 ppm/°C
VMON BIAS MONITOR AND FAULT DETECTION
VMON UVLO Threshold Range
VMON Accuracy (Note 14)
Using VMON pin with 16:1 resistor divider
Full Scale (FS) = 1.15V
2.85
-
-
5
2
-
V
-2
% FS
% FS
µs
VMON Resolution
Full Scale (FS) = 1.15V
-
-
±0.15
200
VMON UV/OV Fault Response Delay
-
TEMPERATURE SENSING
Tested at +100°C
INTERNAL TEMPERATURE SENSOR
Internal Temperature Accuracy
Internal Temperature Resolution
-5
–
1
5
°C
°C
°C
°C
°C
-
-
Thermal Protection Threshold
(Junction Temperature)
Factory default
-
-40
-
125
–
-
125
-
Configurable via PMBus™
Thermal Protection Hysteresis
15
EXTERNAL TEMPERATURE SENSOR: XTEMP0 and XTEMP1
External Temperature Accuracy
External Temperature Resolution
Thermal Protection Threshold
Filter capacitance <100pF
-
±5
1
-
°C
°C
°C
°C
°C
-
-
Factory default
-
-40
-
125
–
-
125
-
Configurable via PMBus™
Thermal protection hysteresis
NOTES:
15
10. Output current is limited by device thermal dissipation.
11. Percentage of Full Scale (FS) with temperature compensation applied.
12. V
OUT
measured at the termination of the VSENxP and VSENxN sense points.
13. For operation at 400kHz, see PMBus™ Power System Management Protocol Specification Part 1, Section 5.2.6.2 for timing parameter limits.
14. Does not include errors due to resistor divider tolerances.
15. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
16. Only 1 output voltage can track the VTRK input: Channel 0, Channel 1 or the output of a 2-phase configuration.
FN7558.3
September 14, 2015
Submit Document Feedback
11
ZL8800
All power management functions can be configured using either
ZL8800 Overview
Digital-DC Architecture Overview
The ZL8800 is an innovative mixed-signal power conversion and
power management IC based on Intersil patented Digital-DC™
technology that provides an integrated, high performance
step-down converter for a wide variety of power supply
applications.
pin configuration techniques described in this document or via
the SMBus interface using PMBus™ commands. Monitoring
parameters can also be preconfigured to provide alerts for
specific conditions. The “PMBus™ Command Summary” on
page 25 contains a listing of all the PMBus™ commands
supported by the ZL8800 and a detailed description of the use of
each of these commands.
Multimode Pins
The ZL8800 DC/DC controller is a dual channel, dual phase
controller based on an architecture that does not require loop
compensation. Adaptive algorithms enable the power converter to
automatically change the operating state to increase efficiency
and overall performance with no user interaction needed.
In order to simplify circuit design, the ZL8800 incorporates
patented multimode pins that allow the user to easily configure
many aspects of the device with no programming. Most power
management features can be configured using these pins. The
multimode pins can respond to four different connections as
shown in Table 2. These pins are sampled when power is applied.
The ZL8800s full digital loop achieves precise control of the
entire power conversion process with no software required
resulting in a very flexible device that is also very easy to use. The
ChargeMode control algorithm is implemented that responds to
output current changes within a single PWM switching cycle,
achieving a smaller total output voltage variation with less output
capacitance than traditional PWM controllers. An extensive set of
power management functions are fully integrated and can be
configured using simple pin connections. The user configuration
can be saved in an internal Nonvolatile Memory (NVM).
Additionally, all functions can be configured and monitored via
the SMBus hardware interface using standard PMBus™
commands, allowing ultimate flexibility. The ZL8800 is compliant
with the PMBus™ Power System Management Protocol
Specification Part I & II version 1.2.
Pin-strap Settings: This is the simplest implementation method,
as no external components are required. Using this method, each
pin can take on one of three possible states: LOW, OPEN, or
HIGH. These pins can be connected to the V25 pin for logic HIGH
settings (excluding VDRVEN, which should be left floating). Using
a single pin, one of three settings can be selected.
TABLE 2. MULTIMODE PIN CONFIGURATION
PIN TIED TO
VALUE
LOW (Logic LOW)
< 0.8 VDC
OPEN (N/C)
No connection
> 2.0 VDC
HIGH (Logic HIGH)
Resistor to SGND
Once enabled, the ZL8800 is immediately ready to regulate
power and perform power management tasks with no
programming required. Advanced configuration options and
real-time configuration changes are available via PMBus™
commands if desired and continuous monitoring of multiple
operating parameters is possible with minimal interaction from a
host controller. Integrated subregulation circuitry enables single
supply operation from any supply between 4.5V and 14V with no
bias supplies needed.
Set by resistor value
V25
LOGIC
HIGH
MULTIMODE
PIN
MULTIMODE
PIN
OPEN
The ZL8800 can be configured by simply connecting its pins
according to the tables provided in the following sections.
Additionally, a comprehensive set of online tools and application
notes are available to help simplify the design process. A
demonstration board is also available to help the user become
familiar with the device. This board can be evaluated as a
standalone platform using pin configuration settings. A
Windows™-based GUI is also provided to enable full configuration
and monitoring capability via the SMBus interface and the
included USB cable.
LOGIC
LOW
PIN-STRAP
SETTINGS
RESISTOR
SETTINGS
FIGURE 4. PIN-STRAP AND RESISTOR SETTING
Power Management Overview
Resistor Settings: This method allows a greater range of
adjustability when connecting a finite value resistor (in a
specified range) between the multimode pin and SGND.
Standard 1% resistor values are used, and only every fourth E96
resistor value is used so the device can reliably recognize the
value of resistance connected to the pin while eliminating the
error associated with the resistor accuracy. Up to 31 unique
selections are available using a single resistor.
The ZL8800 incorporates a wide range of configurable power
management features that are simple to implement with no
external components. Additionally, the ZL8800 includes circuit
protection features that continuously safeguard the device and load
from damage due to unexpected system faults. The ZL8800 can
continuously monitor input voltage and current, output voltage and
current, internal temperature and the temperature of 2 external
thermal diodes. A Power-good output signal is also included to
enable power-on reset functionality for an external processor.
FN7558.3
September 14, 2015
Submit Document Feedback
12
ZL8800
SMBus: Almost any ZL8800 function can be configured via the
Output Voltage and VOUT_MAX Selection
(VSET0,1)
The output voltage may be set to any voltage between 0.54V and
5.5V provided that the input voltage is higher than the desired
SMBus interface using standard PMBus™ commands.
Additionally, any value that has been configured using the
pin-strap or resistor setting methods can also be reconfigured
and/or verified via the SMBus. The PMBus™ commands
description section of this document explains the use of the
PMBus™ commands in detail.
output voltage by at least 1.1V. Using the pin-strap method, V
OUT
can be set to any of the voltages shown in Table 4. V
OUT
can also
be set using a PMBus™ command. VOUT_MAX is also
determined by this pin-strap setting, and is 10% greater than the
VSET0 and VSET1 voltage settings.
Configurable Pins
Four operating parameters can be set using the pin-strap or
resistor setting method: SMBus address (pin 5, SA), output
voltage (pins 10 and 11, VSET0,1), switching frequency (pin 44,
SYNC) and input voltage undervoltage lockout (pin 13, UVLO).
TABLE 4.
RVSET (kΩ)
LOW
OPEN
HIGH
10
VOUT (V)
1.00
1.20
2.50
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.25
RVSET (kΩ)
38.3
42.2
46.4
51.1
56.2
61.9
68.1
75
VOUT (V)
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.50
2.80
3.00
3.30
4.00
5.00
The SMBus device address and the output voltage are the only
parameters that must be set by external pins. All other device
parameters can be set via the PMBus™. The device address is set
using the SA pin. The output voltage is set using the VSET0 and
VSET1 pins.
11
SMBus Device Address Selection (SA)
12.1
13.3
14.7
16.2
17.8
When communicating with multiple SMBus devices using the
SMBus interface, each device must have its own unique address
so the host can distinguish between the devices. The device
address can be set according to the pin-strap options listed in
Table 3. Because the ZL8800 is a 2-channel device, the next
higher sequential address after the selected ZL8800 address
should not be used by any device on the SMBus. For example, if
Address 0x26 is used, 0x27 should not be used by any device
sharing the same SMBus (See DDC_CONFIG command for
details). The SMBus address cannot be changed with a PMBus™
command.
82.5
90.9
100
19.6
21.5
23.7
26.1
28.7
31.6
34.8
110
121
133
TABLE 3. SMBus DEVICE ADDRESS SELECTION
147
RSA
SMBus
RSA
(kΩ)
SMBus
ADDRESS
(kΩ)
ADDRESS
162
LOW
OPEN
10
0x26h
0x28h
0x19h
0x1Ah
0x1Bh
0x1Ch
0x1Dh
0x1Eh
0x1Fh
0x20h
0x21h
0x22h
0x23h
0x24h
0x25h
0x26h
0x27h
42.2
46.4
51.1
56.2
61.9
68.1
75
0x28h
0x29h
0x2Ah
0x2Bh
0x2Ch
0x2Dh
0x2Eh
0x2Fh
0x30h
0x31h
0x32h
0x33h
0x34h
0x35h
0x36h
0x37h
178
Switching Frequency Setting (SYNC)
11
The device’s switching frequency set from 200kHz to 1333kHz
using the pin-strap method as shown in Table 5, or by using a
PMBus™ command. The ZL8800 generates the device switching
frequency by dividing an internal precision 16MHz clock by
integers from 11 to 80. 500kHz (n = 32) and 1000kHz (n = 16)
are not recommended operating frequencies; use 533kHz and
1067kHz for best performance.
12.1
13.3
14.7
16.2
17.8
19.6
21.5
23.7
26.1
28.7
31.6
34.8
38.3
82.5
90.9
100
110
121
133
147
162
178
TABLE 5.
RSYNC (kΩ)
SGND
OPEN
HIGH
10
FREQ (kHz)
200
RSYNC kΩ
23.7
FREQ (kHz)
471
400
26.1
533
1067
200
28.7
571
31.6
615
11
222
34.8
727
12.1
242
38.3
800
13.3
267
42.2
842
FN7558.3
September 14, 2015
Submit Document Feedback
13
ZL8800
TABLE 5. (Continued)
using the pin-strap method as shown in Table 6. UVLO can also be
set or changed using the VIN_UV_FAULT_LIMIT command.
RSYNC (kΩ)
14.7
FREQ (kHz)
RSYNC kΩ
46.4
FREQ (kHz)
889
TABLE 6.
296
320
364
400
421
RUVLO
(kΩ)
UVLO
(V)
RUVLO
(kΩ)
UVLO
(V)
16.2
51.1
1067
17.8
56.2
1143
LOW
OPEN
HIGH
26.1
28.7
31.6
34.8
38.3
42.2
Not used
4.5
46.4
51.1
56.2
61.9
68.1
75
7.42
8.18
19.6
61.9
1231
10.8
4.18
4.59
5.06
5.57
6.13
6.75
8.99
21.5
68.1
1333
9.90
The ZL8800 incorporates an internal Phase-locked Loop (PLL) to
clock the internal circuitry. The PLL can be driven by an external
clock source connected to the SYNC pin. When using the internal
oscillator, the SYNC pin can be configured as a clock source for
other Intersil devices.
10.90
12.00
13.20
14.54
16.00
82.5
90.9
100
By default, the SYNC pin is configured as an input. The device will
automatically check for a clock signal on the SYNC pin each time
EN is asserted. The ZL8800’s oscillator will then synchronize with
the rising edge of the external clock.
Once an input undervoltage fault condition occurs, the user may
determine the desired response to the fault condition. The
following input undervoltage protection response options are
available:
The incoming clock signal must be in the range of 200kHz to
1.33MHz and must be stable when the enable pin (EN0, EN1) is
asserted. When using an external clock, the frequencies are not
limited to discrete values as when using the internal clock. The
external clock signal must not vary more than 10% from its initial
value, and should have a minimum pulse width of 150ns. In the
event of a loss of the external clock signal, the output voltage
may show transient overshoot or undershoot.
1. Shut down and stay off until the fault has cleared and the
device has been disabled and reenabled.
2. Shut down, and when the fault is no longer present, attempt
to restart.
3. Shut down and restart continuously after a delay.
The default response from an undervoltage fault is to shut down
and stay off until the fault has cleared and the device has been
disabled and reenabled (#1).
If loss of synchronization occurs, the ZL8800 will automatically
switch to its internal oscillator and switch at its programmed
frequency.
Refer to the PMBus™ Commands section of this document for
details on how to select specific overvoltage fault response
options using the VIN_UV_FAULT_RESPONSE command.
The SYNC pin can also be configured as an output. The device will
run from its internal oscillator and will drive the SYNC pin so
other devices can be synchronized to it. The SYNC pin will not be
checked for an incoming clock signal while in this mode.
When controlling the ZL8800 exclusively through the PMBus™, a
high voltage setting for UVLO can be used to prevent the ZL8800
from being enabled until a lower voltage for UVLO is set using the
VIN_UV_FAULT_LIMIT command.
The switching frequency can be set to any value between 200kHz
and 1.33MHz using a PMBus™ command. The available
frequencies below 1.33MHz are defined by f
= 16MHz/N,
SW
where 11 ≤ N ≤ 80.
Internal Bias Regulators and Input Supply
Connections
If a value other than f
SW
= 16MHz/N is entered using a PMBus™
command, the internal circuitry will select the switching
frequency value using N as a whole number to achieve a value
close to the entered value. For example, if 810kHz is entered, the
device will select 800kHz (N = 20).
The ZL8800 employs internal Low Dropout (LDO) regulators to
supply bias voltages for internal circuitry, allowing it to operate
from a single input supply. The internal bias regulators are as
follows:
VR6: The VR6 LDO provides a regulated 6.1V bias supply for
internal circuitry. It is powered from the VDD pin. A 4.7µF
ceramic X5R or X7R filter capacitor to SGND is required at the
VR6 pin.
Input Voltage Undervoltage Lockout Setting
(UVLO)
The input Undervoltage Lockout (UVLO) prevents the ZL8800 from
operating when the input falls below a preset threshold, indicating
the input supply is out of its specified range. The input voltage
undervoltage lockout threshold can be set between 2.85V and 16V
VR5: The VR5 LDO provides a regulated 5.1V bias supply for
internal circuitry. It is powered from the VDD pin. A 4.7µF
ceramic X5R or X7R filter capacitor to SGND is required at the
VR5 pin. This supply may be used for to provide a pull-up supply
as long as load current does not exceed 5mA.
V25: The V25 LDO provides a regulated 2.5V bias supply for the
main controller circuitry. It is powered from an internal 5V node.
FN7558.3
September 14, 2015
Submit Document Feedback
14
ZL8800
A 4.7µF ceramic X5R or X7R filter capacitor to SGND is required
at the V25 pin.
used as part of an overall inrush current management strategy or
to precisely control how fast a load IC is turned on. The ZL8800
gives the system designer several options for precisely and
independently controlling both the delay and ramp time periods.
VDRV: The VDRV LDO provides a regulated 5.25V bias supply for
external MOSFET driver ICs or DrMOS integrated drivers/FETs. A
4.7µF ceramic X5R or X7R filter capacitor to PGND is required,
however, additional capacitance will be needed as specified by
the MOSFET driver or DrMOS device selected. The maximum
rated output current is 80mA, but device thermal limits must be
considered. The power dissipated by the VDRV supply will be
(VIN - 5.25V) x IDRV, where IDRV is the current supplied by the
VDRV bias supply. VDRV is enabled by leaving the VDRVEN
unconnected (floating) or connecting it to VR5, and is disabled by
connecting VDRVEN to ground.
The Ton-delay time begins when the EN pin is asserted. The
Ton-delay time is set using the PMBus™ command TON_DELAY.
The Ton-rise time enables a precisely controlled ramp to the
nominal V
value that begins once the Ton-delay time has
OUT
expired. The ramp-up is monotonic and its slope may be precisely
set using the PMBus™ command TON_RISE.
The Ton-delay and Ton-ramp times can be set using PMBus™
commands TON_DELAY and TON_RISE over the serial bus
interface. When the Ton-delay time is set to 0ms, the device will
begin its ramp after the internal circuitry has initialized.
NOTE: The internal bias regulators, VR6, VR5 and V25, are not
designed to be outputs for powering other circuitry. The
multimode pins may be connected to the V25 pin for logic HIGH
settings, and the VR5 supply can be used to provide up to 5mA of
pull-up current for the SDA, SCL, SALRT, DDC and PG pins.
The Ton-delay and Ton-ramp times can be set using PMBus™
commands TON_DELAY and TON_RISE over the serial bus
interface. When the Ton-delay time is set to 0ms, the device will
begin its ramp after the internal circuitry has initialized, which
takes approximately 2ms to complete. The Ton-rise time may be
set to values less than 2ms, however the Ton-rise time should be
set to a value greater than 500µs to prevent inadvertent fault
conditions due to excessive inrush current. A lower Ton-rise time
limit can be estimated using the formula: Ton-rise =
Start-Up Procedure
The ZL8800 follows a specific internal start-up procedure after
power is applied to the VDD pin, as shown in Figure 5.
The device requires approximately 70ms to check for specific
values stored in its internal memory. If the user has stored values
in memory, those values will be loaded.
C
*V /I
where C
is the total output capacitance,
OUT OUT LIMIT
OUT
is the output voltage and I
V
is the current limit setting
OUT
LIMIT
for the ZL8800.
Once this process is completed, the device is ready to accept
commands via the serial interface and the device is ready to be
enabled. If the device is to be synchronized to an external clock
source, the clock frequency must be stable prior to asserting the
EN pin. Once enabled, the device requires approximately 2ms
before its output voltage may be allowed to start its ramp-up
process.
Enable
The enable pins (EN0 and EN1) are used to enable and disable
each channel of the ZL8800. When operated as a 2-phase
converter, use EN0 and ground EN1. The enable pins should be
held low whenever a configuration file or script is used to
configure the ZL8800, or a PMBus™ command is sent that could
potentially damage the application circuit. When the ZL8800 is
used in a self-enabled mode, for example, when EN0 or EN1 is
tied to VR5, or to a resistor divider to VIN, the user must consider
the ZL8800's default factory settings. When a configuration file
is used to configure the ZL8800, the factory default settings are
restored to both the user and default stores in order to set the
ZL8800 to an initialized state. Since the default state of the
ZL8800 is to be enabled when the enable pin is high, it is
possible for the ZL8800 to be enabled while the PMBus™
commands are sent to the ZL8800 during the configuration
process.
After the Ton-delay period has expired, the output will begin to
ramp towards its target voltage according to the preconfigured
Ton-rise time.
Internal Memory Check
60ms to 70ms
Input Power Applied
Device will ignore an
enable signal or PMBus™
commands
Pre-ramp delay
minimum 2ms
Power-Good
delay between enable
signal and start of output
ramp. Additional delay may
be added with PMBus™
command
Device Ready
The ZL8800 provides a Power-good (PG0, PG1) signal for each
channel that indicates the output voltage is within a specified
tolerance of its target level and no fault condition exists. By
default, the PG pin will assert if the output is within 10% of the
target voltage. These limits and the polarity of the pin may be
changed using PMBus™ commands.
FIGURE 5. ZL8800 INTERNAL START-UP PROCEDURE
Ton Delay and Rise Times
A PG delay period is defined as the time from when all conditions
within the ZL8800 for asserting PG are met to when the PG pin is
actually asserted. This feature is commonly used instead of using
an external reset controller to control external digital logic. By
default, the ZL8800 PG delay is set equal to 1ms. The PG delay
In some applications, it may be necessary to set a delay from
when an enable signal is received until the output voltage starts
to ramp to its target value. In addition, the designer may wish to
precisely set the time required for V
to ramp to its target
value after the delay period has expired. These features may be
OUT
FN7558.3
September 14, 2015
Submit Document Feedback
15
ZL8800
may be set using a PMBus™ command as described in the
“PMBus™ Command Summary” on page 25.
VOUT
Desired Output
Voltage
Power Management Functional
Description
Pre-bias voltage
Output Overvoltage Protection
The ZL8800 offers an internal output overvoltage protection
circuit that can be used to protect sensitive load circuitry from
being subjected to a voltage higher than its prescribed limits. A
hardware comparator is used to compare the actual output
voltage (seen at the VSEN pin) to a programmable threshold set
to 15% higher than the target output voltage (the default setting).
If the VSEN voltage exceeds this threshold, the PG pin will
deassert and the device can then respond in a number of ways
as follows:
Time
Ton
Delay
Ton
Rise
VPREBIAS < VTARGET
VOUT
Pre-bias voltage
1. Shut down and stay off until the fault has cleared and the
device has been disabled and reenabled.
Desired Output
Voltage
2. Shut down, and when the fault is no longer present, attempt
to restart.
3. Shut down and restart continuously after a delay.
Time
The default response from an overvoltage fault is to immediately
shut down with no retries (#1).
Ton
Delay
Ton
Rise
Refer to the PMBus™ Commands section of this document for
details on how to select specific overvoltage fault response
options using the VOUT_OV_FAULT_RESPONSE command.
VPREBIAS > VTARGET
FIGURE 6. OUTPUT RESPONSES TO PREBIAS VOLTAGES
If a prebias voltage higher than the target voltage exists after the
preconfigured Ton-delay time and Ton-rise time have completed,
the ZL8800 starts switching with a duty cycle that matches the
prebias voltage. This ensures that the ramp-down from the
prebias voltage is monotonic. The output voltage is then ramped
down to the desired output voltage.
Output Prebias Protection
An output prebias condition exists when an externally applied
voltage is present on a power supply's output before the power
supply's control IC is enabled. Certain applications require that
the converter not be allowed to sink current during start-up if a
prebias condition exists at the output. The ZL8800 provides
prebias protection by sampling the output voltage prior to
initiating an output ramp.
If a prebias voltage higher than the overvoltage limit exists, the
device will not initiate a turn-on sequence and will stay off with
an output OV fault recorded.
If a prebias voltage lower than the desired output voltage is
present after the Ton-delay time, the ZL8800 starts switching
with a duty cycle that matches the prebias voltage. This ensures
that the ramp-up from the prebias voltage is monotonic. The
output voltage is then ramped to the desired output voltage at
the ramp rate set by the TON_RISE command.
Output Overcurrent Protection
The ZL8800 can protect the power supply from damage if the
output is shorted to ground or if an overload condition is imposed
on the output. Once the current limit threshold has been selected
(see “Current Limit Configuration” on page 17), the user may
determine the desired response to the fault condition. The
following overcurrent protection response options are available:
The resulting output voltage rise time will vary depending on the
prebias voltage, but the total time elapsed from the end of the
Ton-delay time to when the Ton-rise time is complete and the
output is at the desired value will match the preconfigured ramp
time, (see Figure 6).
1. Shut down and stay off until the fault has cleared and the
device has been disabled and reenabled.
2. Shut down, and when the fault is no longer present, attempt
to restart.
3. Shut down and restart continuously after a delay.
The default response from an overcurrent voltage fault is to shut
down and stay off until the fault has cleared and the device has
been disabled and reenabled (#1).
Refer to the PMBus™ Commands section of this document for
details on how to select specific overvoltage fault response
options using the IOUT_OC_FAULT_RESPONSE command.
FN7558.3
September 14, 2015
Submit Document Feedback
16
ZL8800
The blanking time represents the time when no current
CURRENT SENSING COMPONENTS
measurement is taken. This is to avoid taking a reading just after
a current load step (less accurate due to potential ringing). It is a
configurable parameter from 0 to 832ns.
The ZL8800 uses the inductor DCR current sensing technique.
Current sensing is achieved by selecting an R/C network as
shown in Figure 7.
ZL8800 provides an adjustable maximum full scale sensing
range. Three ranges are available: ±25mV, ±35mV and ±50mV
maximum input voltage.
VIN
VDRV
ZL8800
PWMH
VDD
GH
BST
GL
L
VOUT
By default current sensing is enabled during the inductor current
down slope period of the switching period (D’). In applications
where the steady state duty cycle is >0.5, for example, a 5V to
3.3V converter, the ZL8800 can be configured to sense current
during the inductor up slope period of the switching cycle (D).
PWML
R1
C1
ISENA
ISENB
The user has the option of selecting how many consecutive
overcurrent readings must occur before an overcurrent fault and
subsequent shutdown are initiated. Either 1, 3, 5, 7, 9, 11 or 13
consecutive faults can be selected.
FIGURE 7. DCR CURRENT SENSING
For the voltage across C to reflect the voltage across the DCR of
1
the inductor, the time constant of the inductor must match the
time constant of the RC network. That is:
Once the ISENSE_CONFIG parameters have been selected, the
user must select the desired current limit thresholds and the
resistance of the sensing element.
RC L / DCR
The current limit thresholds are set with 4 commands:
L
• IOUT_OC_FAULT_LIMIT – this sets the overcurrent threshold
that must be exceeded by the number of consecutive times
chosen in ISENSE_CONFIG.
R1 C1
DCR
For L, use the average of the nominal value and the minimum
value. Include the effects of tolerance, DC bias and switching
frequency on the inductance when determining the minimum
value of L. Use the typical room temperature value for DCR.
• IOUT_UC_FAULT_LIMIT – this is the same as
IOUT_OC_FAULT_LIMIT, but represents the negative current that
flows lower FET during the D’ interval. Large negative currents
can flow during faults such as a higher voltage rail being
shorted to a lower voltage rail.
The value of R should be as small as feasible and no greater
1
than 5kΩ for best signal-to-noise ratio. The designer should
make sure the resistor package size is appropriate for the power
dissipated and include this loss in efficiency calculations. In
• IOUT_AVG_OC_FAULT_LIMIT – this limit is similar to
IOUT_OC_FAULT_LIMIT, but the limit represents an average
reading over several switching cycles. Since it is an average,
the response time is slower, but the limit can be set closer to
the maximum average expected output current.
calculating the minimum value of R , the average voltage across
1
C (which is the average I
· DCR product) is small and can be
1
OUT
neglected. Therefore, the minimum value of R may be
1
approximated by the following equation:
• IOUT_AVG_UC_FAULT_LIMIT – this limit is similar to
IOUT_AVG_OC_FAULT_LIMIT, but represents the negative
current that flows lower FET during the D’ interval.
2
D
VIN VOUT
2
PR1
1 D VOUT
R1min
Input Current Monitor
where P is the maximum power dissipation specification for
R1
the resistor. Once R1
has been calculated, solve for the
min
The input current can be monitored through the IINN and IINP
pins. When there is no input current being measured through the
IINN and IINP pins, the input current can be estimated using the
measured duty cycle and measured average output current. Fault
detection is not allowed using the estimated input current. This
estimation is enabled by setting IIN_SCALE to zero.
maximum value of C from:
1
L
C1max
R1min DCR
and choose the next-lowest readily available value (e.g., for
C1 = 1.86µF, C = 1.5µF is a good choice). Then substitute
max
the chosen value into the same equation and recalculate the
value of R . Choose the 1% resistor standard value closest to this
1
The input current monitor input should be connected across a
current sensing resistor in series with the input supply. The IINP
pin is connected to the input supply side of the current sense
resistor, the IINN pin is connected to the ZL8800 VDD side of the
current sense resistor. Using the IIN_SCALE command, set the
current sense resistor value. Select the current sense resistor
value such that the maximum expected input current times the
current sense resistor value does not exceed the maximum
current sensing input voltage of 20mV.
1
recalculated value of R .
1
Current Limit Configuration
The ZL8800 gives the power supply designer several choices for
the fault response during over or undercurrent condition. The
user can select the number of violations allowed before declaring
fault, a blanking time and the action taken when a fault is
detected. These parameters are configured using the
ISENSE_CONFIG command.
If this feature is not used, IINN and IINP should be tied to VDD.
FN7558.3
September 14, 2015
Submit Document Feedback
17
ZL8800
external resistor string may be used to configure a different
Thermal Overload Protection
tracking ratio. The device that is tracking another output
voltage (slave) must be set to its desired steady-state output
voltage.
The ZL8800 includes an on-chip thermal sensor that continuously
measures the internal temperature of the die. This thermal sensor
is used to provide both over-temperature and under-temperature
protection. If the over-temperature limit is exceeded, or the
temperature falls below the under-temperature limit, the ZL8800
is shut down. The over-temperature and under-temperature limits
are set by the OT_FAULT_LIMIT and UT_FAULT_LIMIT respectively.
The ZL8800 will not attempt to restart until the temperature has
fallen below the OT_WARN_LIMIT for over-temperature faults or
has risen above the UT_WARN_LIMIT for under-temperature faults.
The default temperature limits are +125°C and -45°C, but the
user may set the limits to different values if desired. Note that
setting a higher over-temperature or under-temperature limit may
result in permanent damage to the device. Once the device has
been disabled due to an internal temperature fault, the user may
select one of several fault response options as follows:
The master ZL8800 device in a tracking group is defined as the
device that has the highest target output voltage within the
group. This master device will control the ramp rate of all
tracking devices and is not configured for tracking mode. The
maximum tracking rise time is 1V/ms. The slave device must be
enabled before the master.
Any device that is configured for tracking mode will ignore its
Ton-delay and Ton-rise settings and its output will take on the
turn-on/turn-off characteristics of the reference voltage present
at the VTRK pin.
Tracking mode can be configured by using the TRACK_CONFIG
command.
1. Shut down and stay off until the fault has cleared and the
device has been disabled and reenabled.
Note that current sharing groups that are also configured to track
another voltage do not offer prebias protection; a minimum load
should therefore be enforced to avoid the output voltage from
being held up by an outside source.
2. Shut down, and when the fault is no longer present, attempt
to restart.
V
IN
3. Shut down and restart continuously after a delay.
The default response from an over or under-temperature fault is
to shut down and stay off until the fault has cleared and the
device has been disabled and reenabled (#1).
Q1
ZL8800
Vo2
L1
C
1
Q2
Refer to the PMBus™ Commands section of this document for
details on how to select specific overvoltage fault response
options using the OT_FAULT_RESPONSE and
Vo1
UT_FAULT_RESPONSE commands.
V
OUT
Vo1
Vo2
Voltage Tracking
Numerous high performance systems place stringent demands
on the order in which the power supply voltages are turned on.
This is particularly true when powering FPGAs, ASICs and other
advanced processor devices that require multiple supply voltages
to power a single die. In most cases, the I/O interface operates at
a higher voltage than the core and therefore the core supply
voltage must not exceed the I/O supply voltage according to the
manufacturers' specifications.
TIME
COINCIDENT
V
OUT
The ZL8800 integrates a tracking scheme that allows one of its
outputs (Channel 0 or Channel 1, or the single output in a dual
phase application) to track a voltage that is applied to the VTRK
pin with no external components required. The VTRK pin is an
analog input that, when tracking mode is enabled, configures the
voltage applied to the VTRK pin to act as a reference for the
device’s output regulation.
Vo1
Vo2
TIME
Figure 8 illustrates the typical connection and the two tracking
modes:
RATIOMETRIC
FIGURE 8. TRACKING MODES
• Coincident. This mode configures the ZL8800 to ramp its
output voltage at the same rate as the voltage applied to the
VTRK pin until it reaches its desired output voltage. The device
that is tracking another output voltage (slave) must be set to
its desired steady-state output voltage.
• Ratio-metric. This mode configures the ZL8800 to ramp its
output voltage at a rate that is a percentage of the voltage
applied to the VTRK pin. The default setting is 50%, but an
FN7558.3
September 14, 2015
Submit Document Feedback
18
ZL8800
(noise). Excessive noise on the data and clock lines that cause
Voltage Margining
the voltage on these lines to cross the high and low logic
thresholds of 2.0V and 0.8V respectively will cause command
transmissions to be interrupted and result in slow bus operation
or missed commands. For less than 10 devices on an SMBus a
10kΩ resistor on each line provides good performance.
The ZL8800 offers a simple means to vary its output higher or
lower than its nominal voltage setting in order to determine
whether the load device is capable of operating over its specified
supply voltage range. Margining is controlled through the
OPERATION command.
The ZL8800 accepts most standard PMBus™ commands. When
enabling the device with ON_OFF_CONFIG command, it is
recommended that the enable pin is tied to SGND.
Default margin limits of V
OUT
±5% are preloaded in the factory,
but the margin limits can be modified through PMBus™
commands to be as high as V + 10% or as low as 0V, where
OUT
is the nominal output voltage set point determined by the
V
In addition to bus noise considerations, it is important to ensure
that user connections to the SMBus are compliant to the
PMBus™ command standards. Any device that can malfunction
in a way that permanently shorts SMBus lines will disable
PMBus™ communications. Incomplete PMBus™ commands can
also cause the ZL8800 to halt PMBus™ communications. This
can be corrected by disabling, then reenabling the device.
OUT
VSET pin or the VOUT_COMMAND command.
A safety feature prevents the user from configuring the output
voltage to exceed V
+ 10% under any condition.
OUT
Additionally, the transition rate between the nominal output
voltage and either margin limit can be configured using the
VOUT_TRANSITION_RATE command.
Digital-DC™ Bus
External Voltage Monitoring
The Digital-DC™ Communications (DDC) bus is used to
communicate between Intersil Digital-DC devices, and within the
ZL8800 itself. This dedicated bus provides the communication
channel between devices for features such as sequencing, fault
spreading, and current sharing. The DDC pin must be pulled up to an
external 3.3V or 5.0V supply, (or configured as a push-pull output
using the GLOBAL_USER_CONGFIG command) even if the ZL8800
is operating in stand-alone. In addition, the DDC pin must be pulled
up or configured as a push-pull output before the Enable pin is set
high. Push-pull mode can only be used when the ZL8800 is
operating in stand-alone. The DDC pin on all Digital-DC devices that
utilize sequencing, fault spreading or current sharing must be
connected together. The DDC pin on all Digital-DC devices in an
application should be connected together. A pull-up resistor is
required on the DDC bus in order to guarantee the rise time as
follows:
The voltage monitoring (VMON) pin is available to monitor the
voltage supply for the external driver IC. The VMON input must be
scaled by a 16:1 ratio in order to read-back the VMON voltage
correctly. A 100kΩ and 6.65kΩ resistor divider is recommended.
Overvoltage and undervoltage fault thresholds can be set using
MFR_VMON_OV_FAULT_LIMIT and MFR_ VMON_UV_FAULT_LIMIT
commands. The response to these limits are set using the
VMON_OV_FAULT_RESPONSE and VMON_ UV_FAULT_RESPONSE
commands.
Once the device has been disabled due to VMON fault, the user
may select one of several fault response options as follows:
1. Shut down and stay off until the fault has cleared and the
device has been disabled and reenabled.
2. Shut down, and when the fault is no longer present, attempt
to restart.
Rise time = R * C
PU LOAD
≤ 1 µs
3. Shut down and restart continuously after a delay.
Where R is the DDC bus pull-up resistance and C
PU LOAD
is the
The default response from an over or undervoltage VMON fault is
to shut down and stay off until the fault has cleared and the
device has been disabled and reenabled (#1).
bus loading. The pull-up resistor may be tied to VR5 or to an
external 3.3V or 5V supply as long as this voltage is present prior
to or during device power-up. As a rule of thumb, each device
connected to the DDC bus presents approximately 12pF of
capacitive loading. The ideal design will use a central pull-up
resistor that is well-matched to the total load capacitance. In
power module applications, the user should consider whether to
place the pull-up resistor on the module or on the PCB of the end
application. The minimum pull-up resistance should be limited to
a value that enables any device to assert the bus to a voltage that
will ensure a logic 0 (typically 0.8V at the device monitoring
point) given the pull-up voltage (5V if tied to VR5) and the
pull-down current capability of the ZL8800 (nominally 4mA). As
with SMBus data and clock lines, the DDC data line should be
routed with a closely coupled return or ground plane to minimize
coupled interference (noise). Excessive noise on the DDC signal
can cause the voltage on this line to cross the high and low logic
thresholds of 2V and 0.8V respectively and will cause command
transmissions to be interrupted and result in slow bus operation
or missed commands. For less than 10 devices on the DDC bus a
10kΩ resistor provides good performance.
SMBus Communications
The ZL8800 provides a SMBus digital interface. The ZL8800 can
be used with any standard 2-wire SMBus host device. In addition,
the device is compatible with SMBus version 2.0 and includes an
SALRT line to help mitigate bandwidth limitations related to
continuous fault monitoring. Pull-up resistors are required on the
SMBus. The pull-up resistor may be tied to VR5 or to an external
3.3V or 5V supply as long as this voltage is present prior to or
during device power-up. The ideal design will use a central pull-up
resistor that is well-matched to the total load capacitance. The
minimum pull-up resistance should be limited to a value that
enables any device to assert the bus to a voltage that will ensure
a logic 0 (typically 0.8V at the device monitoring point) given the
pull-up voltage (5V if tied to VR5) and the pull-down current
capability of the ZL8800 (nominally 4mA). A pull-up resistor of
10kΩ is a good value for most applications.
SMBus data and clock lines should be routed with a closely
coupled return or ground plane to minimize coupled interference
FN7558.3
September 14, 2015
Submit Document Feedback
19
ZL8800
TON_RISE commands and choosing appropriate delay and rise
Phase Spreading
durations such that sequel devices start after their associated
prequel devices. The drawback to this method is that if a prequel
device fails to start properly, its sequel device will still start and
ramp on according to its delay and rise time settings.
When multiple point of load converters share a common DC
input supply, it is desirable to adjust the clock phase offset of
each device such that not all devices have coincident rising
edges. Setting each converter to start its switching cycle at a
different point in time can dramatically reduce input capacitance
requirements. Since the peak current drawn from the input
supply is effectively spread out over a period of time, the peak
Fault Spreading
Digital DC devices can be configured to broadcast a fault event
over the DDC bus to the other devices in the group. When a fault
occurs and the device is configured to shut down on a fault, the
device will shut down and broadcast the fault event over the DDC
bus. The other devices on the DDC bus will shut down together if
configured to do so, and will attempt to restart in their prescribed
order if configured to do so.
current drawn at any given moment is reduced and the power
2
losses proportional to I
are reduced.
RMS
In order to enable phase spreading, all converters must be
synchronized to the same switching clock. Configuring the SYNC
pin is described in “Configurable Pins” on page 13. Selecting the
phase offset for the device is accomplished by selecting a device
address according to the following equation:
Active Current Sharing
The two channels of the ZL8800 can be used in parallel to create
a dual phase power rail. The device outputs will share the current
equally within a few percent.
Phase offset = device address x 45°
This behavior is illustrated in Table 7:
TABLE 7.
Figure 9 shows a typical connection for a dual phase application.
When used in this configuration the ZL8800 can current share
between phases without utilizing output voltage droop.
PHASE OFFSET
(°)
PHASE OFFSET
(°)
ADDRESS LSB
ADDRESS LSB
0
1
2
3
4
5
6
7
0
8
9
A
B
C
D
E
F
0
V
IN
45
45
90
90
135
180
225
270
315
135
180
225
270
315
V
OUT
ZL8800
VIN
The phase offset of each device may also be set to any value
between 0° and 360° in 22.5° increments using the
INTERLEAVE PMBus™ command.
Output Sequencing
A group of Intersil devices may be configured to power up in a
predetermined sequence. This feature is especially useful when
powering advanced processors, FPGAs and ASICs that require
one supply to reach its operating voltage prior to another supply
reaching its operating voltage in order to avoid latch-up from
occurring. Multidevice sequencing can be achieved by
configuring each device using the SEQUENCE PMBus™
command.
FIGURE 9. DUAL PHASE EXAMPLE
Multiple device sequencing is achieved by issuing PMBus™
commands to assign the preceding device in the sequencing
chain as well as the device that will follow in the sequencing
chain.
Temperature Monitoring Using XTEMP Pin
Each channel of the ZL8800 supports measurement of an
external device temperature using either a thermal diode
integrated in a processor, FPGA or ASIC, or using a discrete
diode-connected 2N3904 NPN transistor. Figure 10 on page 21
illustrates the typical connections required. A noise filtering
capacitor, not exceeding 100pF, should be connected across the
external temperature sensing device. The external temperature
sensors can be used to provide the temperature reading for
over-temperature and under-temperature faults. The external
sensors can also be used to provide more accurate temperature
compensation for inductor DCR current sensing by being placed
The enable (EN) pins of all devices in a sequencing group must be
tied together and driven high to initiate a sequenced turn-on of
the group. Enable must be driven low to initiate a sequenced
turnoff of the group.
Sequencing can also be accomplished by connecting the enable
pin of a sequel device to the power-good pin of a prequel device.
Sequencing is also achieved by using the TON_DELAY and
FN7558.3
September 14, 2015
Submit Document Feedback
20
ZL8800
close to the inductor. These options for the external temperature
VIN
sensors are selected using the USER_CONFIG PMBus™
command.
QH
QL
XTEMPxP
100 pF
ZL
L
ZL8800
VOUT
C
2N3904
XTEMPxN
Discrete NPN
FIGURE 11. SYNCHRONOUS BUCK CONVERTER
Figure 11 illustrates the basic synchronous buck converter
topology showing the primary power train components. This
converter is also called a step-down converter, as the output
voltage must always be lower than the input voltage.
µP
FPGA
DSP
XTEMPxP
100pF
ZL
ASIC
XTEMPxN
DUAL OUTPUT PWM PER CHANNEL
The ZL8800 has been designed to provide independent upper
and lower FET drive signals to a 2-input MOSFET driver such as
the ZL1505.
Embedded Thermal Diode
FIGURE 10. EXTERNAL TEMPERATURE MONITORING
The ZL8800 utilizes adaptive dead time control to improve the
power conversion efficiency. The ZL8800 monitors the power
converter’s operating conditions and continuously adjusts the
turn-on and turn-off timing of the high-side and low-side driver
input signals to optimize the overall efficiency of the power supply.
Nonvolatile Memory and Security Features
The ZL8800 has internal nonvolatile memory where user
configurations are stored. Integrated security measures ensure
that the user can only restore the device to a level that has been
made available to them. During the initialization process, the
ZL8800 checks for stored values contained in its internal
non-volatile memory. The ZL8800 offers two internal memory
storage units that are accessible by the user as follows:
The ZL8800 can also be used with single-ended DrMOS
integrated driver and MOSFET devices. Power supplies using
DrMOS devices can be made smaller than discrete solutions
utilizing separate drivers and MOSFETs, but at a slightly lower
efficiency. The option to use DrMOS or drivers and discrete
MOSFETs is set using the USER_CONFIG command.
• Default Store: A power supply module manufacturer may want
to protect the module from damage by preventing the user
from being able to modify certain values that are related to the
physical construction of the module. In this case, the module
manufacturer would use the Default Store and would allow the
user to restore the device to its default setting but would
restrict the user from restoring the device to the factory
settings.
Power Train Component Selection
The ZL8800 is a dual output or dual phase synchronous buck
converter that uses external Drivers, MOSFETs, inductors and
capacitors to perform the power conversion process. The proper
selection of the external components is critical for optimized
performance.
• User Store: The manufacturer of a piece of equipment may
want to provide the ability to modify certain power supply
settings while still protecting the equipment from modifying
values that can lead to a system level fault. The equipment
manufacturer would use the User Store to achieve this goal.
To select the appropriate external components for the desired
performance goals, the power supply requirements listed in
Table 8 must be known.
TABLE 8. POWER SUPPLY REQUIREMENTS
The User Store takes priority over the Default Store. If there are
no values set in the User or Default Store, then the device will use
the pin-strap setting value.
PARAMETER
EXAMPLE VALUE
Input Voltage (V
)
12V
1.2V
30A
IN
Output Voltage (V
)
OUT
DC/DC Converter Design
Output Current (I
)
OUT
The ZL8800 operates as a voltage-mode, synchronous buck
converter with a selectable constant frequency pulse width
modulator (PWM) control scheme that uses external driver,
MOSFETs, capacitors and an inductor to perform power
conversion.
Output Voltage Ripple (V
)
1% of V
OUT
orip
Output Load Step (I
)
50% of I
o
ostep
Output Load Step Rate
10A/µs
Output Deviation Due to Load Step
Maximum PCB Temperature
Desired Efficiency
±2%
85°C
90%
Other Considerations
Optimize for small size
FN7558.3
September 14, 2015
Submit Document Feedback
21
ZL8800
I
is given by:
DESIGN GOAL TRADE-OFFS
Lrms
The design of the buck power stage requires several
2
IL
12
ILrms IOUT 2
compromises among size, efficiency and cost. The inductor core
loss increases with frequency, so there is a trade-off between a
small output filter made possible by a higher switching frequency
and getting better power supply efficiency. Size can be decreased
by increasing the switching frequency at the expense of
efficiency. Cost can be minimized by using through-hole
inductors and capacitors; however these components are
physically large.
Where I
is the maximum output current. Next, calculate the
OUT
core loss of the selected inductor. Since this calculation is
specific to each inductor and manufacturer, refer to the chosen
inductor datasheet. Add the core loss and the ESR loss and
compare the total loss to the maximum power dissipation
recommendation in the inductor datasheet.
To start the design, select a switching frequency based on
Table 9. This frequency is a starting point and may be adjusted as
the design progresses.
OUTPUT CAPACITOR SELECTION
Several trade-offs must also be considered when selecting an
output capacitor. Low ESR values are needed to have a small
TABLE 9. CIRCUIT DESIGN CONSIDERATIONS
output deviation (V
) during transient load steps and low output
step
FREQUENCY RANGE
200 to 400kHz
EFFICIENCY
Highest
CIRCUIT SIZE
Larger
voltage ripple (ΔV). However, capacitors with low ESR, such as X5R
and X7R dielectric ceramic capacitors, also have relatively low
capacitance values. Many designs can use a combination of high
capacitance devices and low ESR devices in parallel.
400 to 800kHz
Moderate
Lower
Smaller
800kHz to 1.33MHz
Smallest
For high ripple currents, a low capacitance value can cause a
significant amount of output voltage ripple. Likewise, in high
transient load steps, a relatively large amount of capacitance is
needed to minimize the output voltage deviation while the
inductor current ramps up or down to the new steady state
output current value.
INDUCTOR SELECTION
The output inductor selection process must include several
trade-offs. A high inductance value will result in a low ripple
current (ΔI ), which will reduce output capacitance and produce a
L
low output ripple voltage, but may also compromise output
transient load performance. Therefore, a balance must be struck
between output ripple and optimal load transient performance. A
good starting point is to select the output inductor ripple equal to
As a starting point, apportion one-half of the output ripple
voltage to the capacitor ESR and the other half to capacitance, as
shown in the following equations:
IL
30 to 50% of the maximum output current (I
).
OUT
COUT
V
ΔI = 0.5* I
OUT
L
8 fsw
2
Now the output inductance can be calculated using the following
equation, where V is the input voltage:
IN
V
ESR
VOUT
VIN
2IL
VOUT 1
Use these values to make an initial capacitor selection, using a
single capacitor or several capacitors in parallel.
L
fsw IL
After a capacitor has been selected, the resulting output voltage
ripple can be calculated using the following equation:
The average inductor current is equal to the maximum output
current. The peak inductor current (I ) is calculated using the
Lpk
is the maximum output current:
IL
V IL ESR
8 fsw COUT
following equation where I
OUT
I
ILpk IOUT
Because each part of this equation was made to be less than or
equal to half of the allowed output ripple voltage, the ΔV should
be less than the desired maximum output ripple.
2
Select an inductor rated for the average DC current and with
saturation current rating above the peak current calculated above.
INPUT CAPACITOR
Once an inductor is selected, the DCR and core losses in the
inductor are calculated. Use the DCR specified in the inductor
manufacturer’s datasheet.
It is highly recommended that dedicated input capacitors be
used in any point-of-load design, even when the supply is
powered from a heavily filtered 5V or 12V “bulk” supply from an
off-line power supply. This is because of the high RMS ripple
current that is drawn by the buck converter topology. This ripple
2
P
DCR ILrms
LDCR
(I
) can be determined from the following equation:
inRMS
IinRMS IOUT D
FN7558.3
September 14, 2015
Submit Document Feedback
22
ZL8800
Without capacitive filtering near the power supply circuit, this
MOSFET THERMAL CHECK
current would flow through the supply bus and return planes,
coupling noise into other system circuitry. The input capacitors
should be rated above the ripple current calculated above and
the maximum expected input voltage.
Once the power dissipations for QH and QL have been calculated,
the MOSFET’s junction temperature can be estimated. Using the
junction-to-case thermal resistance (R ) given in the MOSFET
th
manufacturer’s datasheet and the expected maximum printed
circuit board temperature, calculate the junction temperature as
follows:
QL SELECTION
The bottom or lower MOSFET should be selected with the lowest
Tj max Tpcb P Rth
Q
possible r
cost.
while maintaining the desired circuit size and
DS(ON)
To calculate power losses and junction temperature rise in
DrMOS devices, consult the datasheet and application notes for
the DrMOS device selected.
Calculate the RMS current in QL as follows:
IQLRMS IOUT 1 D
EFFICIENCY OPTIMIZED DRIVER DEAD TIME CONTROL
Calculate the power dissipated due to r
as follows:
DS(ON)
The ZL8800 utilizes a closed loop algorithm to optimize the dead
time applied between the gate drive signals for the top and
bottom FETs. In a synchronous buck converter, the MOSFET drive
circuitry must be designed such that the top and bottom
MOSFETs are never in the conducting state at the same time.
Potentially damaging currents flow in the circuit if both top and
bottom MOSFETs are simultaneously on for periods of time
exceeding a few nanoseconds. Conversely, long periods of time in
which both MOSFETs are off reduce overall circuit efficiency by
allowing current to flow in their parasitic body diodes.
2
P RDSON
Ibotrms
QL
Note that the r
given in the manufacturer’s datasheet is
DS(ON)
measured at +25°C. The actual r
in the end-use
DS(ON)
application will be much higher. Select a candidate MOSFET, and
calculate the required gate drive current as follows:
Ig fSW Qg
MOSFETs with lower r
DS(ON)
tend to have higher gate charge
It is therefore advantageous to minimize this dead time to
provide optimum circuit efficiency. In the first order model of a
buck converter, the duty cycle is determined by the equation:
requirements, which increases the current and resulting power
required to turn them on and off.
QH SELECTION
VOUT
D
In addition to the r
loss and gate charge loss, QH also has
DS(ON)
switching loss. Select QH with a lower gate charge, keeping in
mind that QH’s r will be higher as a result. As was done
VIN
DS(ON)
However, non-idealities exist that cause the real duty cycle to
extend beyond the ideal. Dead time is one of those nonidealities
that can be manipulated to improve efficiency. The ZL8800 has
an internal algorithm that constantly adjusts dead time
nonoverlap to minimize duty cycle, thus maximizing efficiency.
This circuit will null out dead time differences due to component
variation, temperature and loading effects. This algorithm is
independent of application circuit parameters such as MOSFET
type, gate driver delays, rise and fall times and circuit layout. In
addition, it does not require drive or MOSFET voltage or current
waveform measurements. Adaptive dead time is enabled using
the DEADTIME_CONFIG PMBus™ command. Adaptive dead time
is only effective when a discrete driver (such as the ZL1505) and
MOSFETs are used. When DrMOS devices are selected using
USER_CONFIG, adaptive dead time is automatically disabled.
Dead time minimum and maximum limits can be set using the
DEADTIME PMBus™ command.
with QL, calculate the RMS current as follows:
IQHRMS IOUT D
2
P
RDSON IQHRMS
QH
Next, calculate the switching time using:
Qg
tSW
IDR
Where Q is the gate charge of the selected QH and I is the
DR
g
peak gate drive current available from the gate drive IC.
To calculate the switching time, use the ZL1505s minimum
guaranteed drive current of 3 A for a conservative design. Using
the calculated switching time, calculate the switching power loss
in QH using:
Monitoring via SMBus
P
VINM tsw IOUT fsw
swtop
A system controller can monitor a wide variety of different
ZL8800 parameters through the SMBus interface. The device
can monitor for fault conditions by monitoring the SALRT pin,
which will be asserted when any number of preconfigured fault
conditions occur.
The total power dissipated by QH is given by the following
equation:
PQHtot P P
QH
swtop
FN7558.3
September 14, 2015
Submit Document Feedback
23
ZL8800
The device can also be monitored continuously for any number of
power conversion parameters including but not limited to the
following:
The PMBus™ Host should respond to SALRT as follows:
1. ZL device pulls SALRT Low.
2. PMBus™ Host detects that SALRT is now low, performs
transmission with Alert Response Address to find which ZL
device is pulling SALRT low.
• Input voltage
• Output voltage
3. PMBus™ Host talks to the ZL device that has pulled SALRT
low. The actions that the host performs are up to the System
Designer.
• Input current
• Output current
• Internal junction temperature
• Temperature of an external device
• Switching frequency
• Duty cycle
If multiple devices are faulting, SALRT will still be low after doing
the above steps and will require transmission with the Alert
Response Address repeatedly until all faults are cleared.
Please refer to the PMBus™ Commands section of this document
for details on how to monitor specific parameters via the SMBus
interface.
• Fault status information
FN7558.3
September 14, 2015
Submit Document Feedback
24
ZL8800
PMBus™ Command Summary
DATA
TYPE FORMAT
DEFAULT
VALUE
CODE
COMMAND NAME
DESCRIPTION
DEFAULT SETTING
00h PAGE
Selects Controller 0, 1, or both
Enable/disable, margin settings
On/off configuration settings
Clears faults
R/W
R/W
R/W
BIT
BIT
BIT
00h
00h
17h
N/A
N/A
N/A
N/A
N/A
13h
Both controllers addressed
01h OPERATION
Immediate off, nominal margin
02h ON_OFF_CONFIG
03h CLEAR_FAULTS
ENABLE pin control, active high
Write N/A
Write N/A
Write N/A
Write N/A
Write N/A
N/A
11h STORE_DEFAULT_ALL
12h RESTORE_DEFAULT_ALL
15h STORE_USER_ALL
16h RESTORE_USER_ALL
20h VOUT_MODE
Stores values to default store
Restores values from default store
Stores values to user store
Restores values from user store
N/A
N/A
N/A
N/A
Reports V
OUT
mode and exponent
set-point
Read
BIT
Linear Mode, Exponent = -13
21h VOUT_COMMAND
23h VOUT_CAL_OFFSET
Sets nominal V
OUT
R/W L16u
R/W L16u
Pin-strap Setting
0V
Applies offset voltage to V
OUT
set-point
0000h
1.1 X VOUT_COMMAND pin-strap
setting
24h VOUT_MAX
Sets maximum V
OUT
set-point
R/W L16u
R/W L16u
R/W L16u
1.05 x VOUT_COMMAND pin-strap
setting
25h VOUT_MARGIN_HIGH
26h VOUT_MARGIN_LOW
27h VOUT_TRANSITION_RATE
Sets V
set-point during margin high
OUT
0.95 x VOUT_COMMAND pin-strap
setting
Sets V
Sets V
set-point during margin low
transition rate during margin
OUT
OUT
R/W
L11
BA00h
0000h
1V/ms
commands
28h VOUT_DROOP
Sets V/I slope
R/W
R/W
L11
L11
0mV/A
33h FREQUENCY_SWITCH
Sets switching frequency
Pin-strap setting
Configures phase offset during group
operation
37h INTERLEAVE
R/W
BIT
Set by pin-strapped PMBus™ address
38h IOUT_CAL_GAIN
Sets impedance of current sense circuit R/W
Sets an offset to I sense circuit R/W
L11
L11
AA66h
0000h
0.3mΩ
39h IOUT_CAL_OFFSET
0A
OUT
1.15 x VOUT_COMMAND pin-strap
setting
40h VOUT_OV_FAULT_LIMIT
41h VOUT_OV_FAULT_RESPONSE
44h VOUT_UV_FAULT_LIMIT
45h VOUT_UV_FAULT_RESPONSE
46h IOUT_OC_FAULT_LIMIT
Sets the V
overvoltage fault threshold R/W L16u
OUT
Sets the V
overvoltage fault response R/W
undervoltage fault
BIT
80h
Disable, no retry
OUT
OUT
Sets the V
threshold
0.85 x VOUT_COMMAND pin-strap
setting
R/W L16u
Sets the V
undervoltage fault response R/W
BIT
80h
Disable, no retry
20 A
OUT
Sets the I
threshold
peak overcurrent fault
OUT
R/W
L11
DA80h
Sets the I
threshold
valley undercurrent fault
OUT
4Bh IOUT_UC_FAULT_LIMIT
R/W
R/W
L11
-1 x IOUT_OC_FAULT_LIMIT
4Fh OT_FAULT_LIMIT
50h OT_FAULT_RESPONSE
51h OT_WARN_LIMIT
52h UT_WARN_LIMIT
53h UT_FAULT_LIMIT
Sets the over-temperature fault limit
L11
BIT
EBE8h
80h
+125˚C
Sets the over-temperature fault response R/W
Sets the over-temperature warning limit R/W
Sets the under-temperature warning limit R/W
Disable, no retry
+110°C
-30°C
L11
L11
L11
EB70h
DC40h
E530h
Sets the under-temperature fault limit
R/W
R/W
-45°C
Sets the under-temperature fault
response
54h UT_FAULT_RESPONSE
55h VIN_OV_FAULT_LIMIT
BIT
80h
Disable, no retry
14V
Sets the V overvoltage fault threshold R/W
IN
L11
D380h
FN7558.3
September 14, 2015
Submit Document Feedback
25
ZL8800
PMBus™ Command Summary (Continued)
DATA
TYPE FORMAT
DEFAULT
VALUE
CODE
COMMAND NAME
DESCRIPTION
Sets the V overvoltage fault response
DEFAULT SETTING
Disable, no retry
56h VIN_OV_FAULT_RESPONSE
57h VIN_OV_WARN_LIMIT
R/W
R/W
BIT
80h
IN
Sets the V overvoltage warning
IN
threshold
L11
D360h
13.5V
Sets the V undervoltage warning
IN
threshold
1.03 x VIN_UV_FAULT_LIMIT
pin-strap setting
58h VIN_UV_WARN_LIMIT
R/W
L11
N/A
59h VIN_UV_FAULT_LIMIT
Sets the V undervoltage fault threshold R/W
IN
L11
BIT
N/A
80h
Pin-strap setting
Disable, no retry
5Ah VIN_UV_FAULT_RESPONSE
Sets the V undervoltage fault response R/W
IN
Sets the voltage threshold for Power-good
indication
0.9 x VOUT_COMMAND pin-strap
setting
5Eh POWER_GOOD_ON
60h TON_DELAY
61h TON_RISE
R/W L16u
N/A
CA80h
CA80h
0000h
N/A
Sets the delay time from enable to V
rise
OUT
R/W
R/W
R/W
R/W
L11
L11
L11
L11
5ms
Sets the rise time of V
and TON_DELAY
after ENABLE
OUT
5ms
Sets the delay time from DISABLE to start
of V fall
64h TOFF_DELAY
65h TOFF_FALL
0ms
OUT
Sets the fall time for V
and TOFF_DELAY
after DISABLE
OUT
1.0 x TON_RISE
78h STATUS_BYTE
79h STATUS_WORD
7Ah STATUS_VOUT
7Bh STATUS_IOUT
7Ch STATUS_INPUT
7Dh STATUS_TEMP
Summary of most critical faults
Summary of critical faults
Read
Read
Read
Read
Read
Read
BIT
BIT
BIT
BIT
BIT
BIT
00h
0000h
00h
no faults
no faults
no faults
no faults
no faults
no faults
Reports V
warnings/faults
warnings/faults
OUT
Reports I
00h
OUT
Reports input warnings/faults
00h
Reports temperature warnings/faults
00h
Reports communication, memory, logic
errors
7Eh STATUS_CML
Read
Read
BIT
BIT
00h
00h
no errors
no faults
Reports voltage monitoring/clock
synchronization faults
80h STATUS_MFR_SPECIFIC
88h READ_VIN
89h READ_IIN
8Bh READ_VOUT
8Ch READ_IOUT
Reports input voltage measurement
Reports input current measurement
Reports output voltage measurement
Reports output current measurement
Read L11
Read L11
Read L16u
Read L11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Reports internal temperature
measurement
8Dh READ_TEMPERATURE_1
8Eh READ_TEMPERATURE_2
Read L11
Read L11
N/A
N/A
N/A
N/A
Reports external temperature
measurement
94h READ_DUTY_CYCLE
95h READ_FREQUENCY
99h MFR_ID
Reports actual duty cycle
Read L11
Read L11
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Reports actual switching frequency
Sets a user defined identification
Sets a user defined revision
N/A
R/W
R/W
R/W
R/W
R/W
ASC
ASC
ASC
ASC
ASC
<null>
<null>
<null>
<null>
<null>
9Bh MFR_REVISION
9Ch MFR_LOCATION
9Dh MFR_DATE
Sets a user defined location identifier
Sets a user defined date
9Eh MFR_SERIAL
ADh IC_DEVICE_ID
AEh IC_DEVICE_REV
Sets a user defined serialized identifier
Reports device identification information Read CUS 49A02400h Intersil, ZL8800
Reports device revision information Read CUS 00000000h Initial Release
FN7558.3
September 14, 2015
Submit Document Feedback
26
ZL8800
PMBus™ Command Summary (Continued)
DATA
TYPE FORMAT
DEFAULT
VALUE
CODE
COMMAND NAME
DESCRIPTION
DEFAULT SETTING
B0h USER_DATA_00
BFh DEADTIME_MAX
Sets a user defined data
R/W
R/W
ASC
BIT
N/A
<null>
Sets the max dead time value for the
adaptive dead time
3838h
56ns, 56ns
Downslope, 5 fault count, 256ns
blanking, low range
D0h ISENSE_CONFIG
D1h USER_CONFIG
D2h IIN_CAL_GAIN
D3h DDC_CONFIG
Configures current sensing circuitry
Configures several user-level features
R/W
R/W
R/W
R/W
BIT
BIT
BIT
BIT
4204h
0402h
C200h
N/A
Enable XTEMP0, 1, PG open-drain,
DRMOS enabled
Sets the resistance of the input current
sensing resistor
2mΩ
Configures the DDC addressing and
current sharing
Set by pin-strapped PMBus™ address
Sets the delay between PG threshold and
PG assertion
D4h POWER_GOOD_DELAY
D6h INDUCTOR
R/W
R/W
R/W
L11
L11
L11
BA00h
B23D
1ms
Sets the inductor value
0.56µH
5%
% MARGIN_HIGH, LOW above/below
VOUT_COMMAND
D7h VOUT_MARGIN_RATIO
CA80h
Configures output voltage OV/UV fault
detection
Low-side FET off on fault, 1 violation
triggers fault.
D8h OVUV_CONFIG
D9h XTEMP_SCALE
DAh XTEMP_OFFSET
R/W
R/W
R/W
BIT
L11
L11
00h
Calibrates external temperature sensor
BA00h
0000h
1/°C
Offset calibration for external
temperature sensor
No offset
DCh TEMPCO_CONFIG
DDh DEADTIME
Sets tempco settings
R/W
R/W
BIT
27h
3900ppm/°C
16ns/16ns
Sets default dead time settings
L8s
1010h
Configures the adaptive dead time
optimization mode
Adaptive dead time enabled,
8ns/8ns
DEh DEADTIME_CONFIG
R/W
BIT
0808h
DFh ASCR_CONFIG
E0h SEQUENCE
Configures the ASCR settings
R/W
R/W
R/W
BIT
BIT
BIT
015A0100h Gain = 256, Residual = 90
DDC rail sequencing configuration
Configures voltage tracking modes
Configures group ID, fault spreading,
00h
00h
Prequel and sequel disabled
Tracking disabled
E1h TRACK_CONFIG
Ignore broadcast, sequenced
shutdown
E2h DDC_GROUP
R/W
BIT
000000h
N/A
OPERATION and V
OUT
E4h DEVICE_ID
Returns the device identifier string
Read ASC
ZL8800, current revisions
Disable, no retry
Configures the I
response
overcurrent fault
OUT
E5h MFR_IOUT_OC_FAULT_RESPONSE
R/W
R/W
R/W
R/W
R/W
Read
Read
R/W
BIT
BIT
L11
L11
BIT
BIT
BIT
BIT
80h
Configures the I
response
undercurrent fault
OUT
E6h MFR_IOUT_UC_FAULT_RESPONSE
E7h IOUT_AVG_OC_FAULT_LIMIT
E8h IOUT_AVG_UC_FAULT_LIMIT
E9h USER_GLOBAL_CONFIG
EAh SNAPSHOT
80h
N/A
Disable, no retry
Sets the I
threshold
average overcurrent fault
OUT
0.8 x IOUT_OC_FAULT_LIMIT
0.8 x IOUT_UC_FAULT_LIMIT
Numerous device settings
<null>
Sets the I
threshold
average undercurrent fault
OUT
N/A
Sets options pertaining to advanced
features
0000h
N/A
32-byte read back of parametric and
status values
Indicates recently saved parameter
values
EBh BLANK_PARAMS
FFF...FFFh <null>
00000000h <null>
Configures fault group compatibility with
older Intersil digital power devices
F0h LEGACY_FAULT_GROUP
FN7558.3
September 14, 2015
Submit Document Feedback
27
ZL8800
PMBus™ Command Summary (Continued)
DATA
TYPE FORMAT
DEFAULT
VALUE
CODE
COMMAND NAME
DESCRIPTION
DEFAULT SETTING
F3h SNAPSHOT_CONTROL
F4h RESTORE_FACTORY
Snapshot feature control command
R/W
BIT
N/A
N/A
N/A
N/A
Restores device to the hard-coded default
values
Write N/A
Sets the VMON overvoltage fault
threshold
F5h MFR_VMON_OV_FAULT_LIMIT
R/W
R/W
L11
L11
D300h
12V
Sets the VMON undervoltage fault
threshold
F6h MFR_VMON_UV_FAULT_LIMIT
F7h MFR_READ_VMON
CA40h
N/A
4.5V
N/A
Reads the VMON voltage
Read L11
Configures the VMON overvoltage fault
response
F8h VMON_OV_FAULT_RESPONSE
R/W
R/W
BIT
BIT
80h
Disable, no retry
Configures the VMON undervoltage fault
response
F9h VMON_UV_FAULT_RESPONSE
80h
01h
Disable, no retry
FAh SECURITY_LEVEL
FBh PRIVATE_PASSWORD
FCh PUBLIC_PASSWORD
FDh UNPROTECT
Reports the security level
Read Hex
Public security level
Sets the private password string
Sets the public password string
R/W
R/W
ASC
ASC
00…00h <null>
00…00h <null>
FF…FFh N/A
Identifies which commands are protected R/W Custom
PMBus™ Data Formats
Linear-11 (L11)
L11 data format uses 5-bit two’s compliment exponent (N) and 11-bit two’s compliment mantissa (Y) to represent real world decimal
value (X).
Data Byte High
Data Byte Low
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
Exponent (N)
Mantissa (Y)
N
Relation between real world decimal value (X), N and Y is: X = Y·2
Linear-16 Unsigned (L16u)
L16u data format uses a fixed exponent (hard-coded to N = -13h) and a 16-bit unsigned integer mantissa (Y) to represent real world
-13
decimal value (X). Relation between real world decimal value (X), N and Y is: X = Y·2
Linear-16 Signed (L16s)
L16s data format uses a fixed exponent (hard-coded to N = -13h) and a 16-bit two’s compliment mantissa (Y) to represent real world
decimal value (X).
-13
Relation between real world decimal value (X), N and Y is: X = Y·2
Bit Field (BIT)
Breakdown of Bit Field is provided in “PMBus™ Command Detail” on page 29.
Custom (CUS)
Breakdown of Custom data format is provided in “PMBus™ Command Detail” on page 29. A combination of Bit Field and integer are
common type of Custom data format.
ASCII (ASC)
A variable length string of text characters uses ASCII data format.
FN7558.3
September 14, 2015
Submit Document Feedback
28
ZL8800
PMBus™ Command Detail
PAGE (00h)
Definition: Selects Controller 0, Controller 1 or both Controllers 0 and 1 to receive commands. All commands following this command
will be received and acted on by the selected controller or controllers.
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: No
Default Value: 00h (Page 0)
Units: N/A
COMMAND
Format
PAGE (00h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BITS 7:4
BITS 3:0
0000
PAGE
0000
0000
1111
0
1
0001
1111
Both
OPERATION (01h)
Definition: Sets Enable, Disable and V
Margin settings. Data values of OPERATION that force margin high or low only take effect
OUT
when the MGN pin is left open (i.e., in the NOMINAL margin state). This command can also be monitored to read the operating state of
the device on bits 7:6.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 00h (immediate off)
Units: N/A
COMMAND
Format
OPERATION (01h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BITS 3:0
BITS 7:6
BITS 5:4
00
(NOT USED)
UNIT ON OR OFF
MARGIN STATE
N/A
00
0000
0000
Immediate off
(No sequencing)
01
00
Soft off
N/A
(With sequencing)
10
10
10
00
01
10
0000
0000
0000
On
On
On
Nominal
Margin Low
Margin High
NOTE: Bit combinations not listed above may cause command errors.
FN7558.3
September 14, 2015
Submit Document Feedback
29
ZL8800
ON_OFF_CONFIG (02h)
Definition: Configures the interpretation and coordination of the OPERATION command and the ENABLE pin (EN).
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 17h (ENABLE pin control, active high, turn off output immediately – no ramp down)
Units: N/A
COMMAND
Format
ON_OFF_CONFIG (02h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
1
0
1
1
1
BIT NUMBER
PURPOSE
Not Used
BIT VALUE
000
MEANING
7:5
Not Used
Device starts any time power is present regardless of ENABLE pin or
OPERATION command states.
000
Sets the default to either operate any time
power is present or for the on/off to be
controlled by ENABLE pin, OPERATION
command, or when both the Enable pin and
OPERATION command are valid.
101
110
Device starts from ENABLE pin only.
4:2
Device starts from OPERATION command only.
Device starts when the ENABLE pin is active and OPERATION “on”
command has been sent.
111
0
1
0
1
Active low (Pull pin low to start the device)
Active high (Pull pin high to start the device)
Use the programmed ramp down settings
Turn off the output immediately
1
0
Polarity of the ENABLE pin
ENABLE pin action when commanding the unit
to turn off
CLEAR_FAULTS (03h)
Definition: Clears all fault bits in all registers and releases the SALRT pin (if asserted) simultaneously. If a fault condition still exists, the
bit will reassert immediately. This command will not restart a device if it has shut down, it will only clear the faults.
Paged or Global: Global
Data Length in Bytes: 0 Byte
Data Format: N/A
Type: Write only
Protectable: Yes
Default Value: N/A
Units: N/A
STORE_DEFAULT_ALL (11h)
Definition: Stores all current PMBus™ values from the operating memory into the nonvolatile DEFAULT Store memory. To clear the
DEFAULT store, perform a RESTORE_FACTORY then STORE_DEFAULT_ALL. To add to the DEFAULT store, perform a
RESTORE_DEFAULT_ALL, write commands to be added, then STORE_DEFAULT_ALL. This command should not be used during device
operation, the device will be unresponsive for 20ms while storing values.
Paged or Global: Global
Data Length in Bytes: 0
Data Format: N/A
Type: Write only
Default Value: N/A
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
30
ZL8800
RESTORE_DEFAULT_ALL (12h)
Definition: Restores PMBus™ settings from the nonvolatile DEFAULT Store memory into the operating memory. These settings are
loaded at power-up if not superseded by settings in USER store. Security level is changed to level 1 following this command. This
command should not be used during device operation, the device will be unresponsive for 20ms while storing values.
Paged or Global: Global
Data Length in Bytes: 0
Data Format: N/A
Type: Write only
Default Value: N/A
Units: N/A
STORE_USER_ALL (15h)
Definition: Stores all PMBus™ settings from the operating memory to the nonvolatile USER store memory. To clear the USER store,
perform a RESTORE_FACTORY then STORE_USER_ALL. To add to the USER store, perform a RESTORE_USER_ALL, write commands to
be added, then STORE_USER_ALL. This command should not be used during device operation, the device will be unresponsive for 20ms
while storing values.
Paged or Global: Global
Data Length in Bytes: 0
Data Format: N/A
Type: Write only
Default Value: N/A
Units: N/A
RESTORE_USER_ALL (16h)
Definition: Restores all PMBus™ settings from the USER store memory to the operating memory. Command performed at power-up.
Security level is changed to Level 1 following this command. This command should not be used during device operation, the device will
be unresponsive for 20ms while storing values.
Paged or Global: Global
Data Length in Bytes: 0
Data Format: N/A
Type: Write only
Default Value: N/A
Units: N/A
VOUT_MODE (20h)
Definition: Reports the V
Data Length in Bytes: 1
Data Format: BIT
mode and provides the exponent used in calculating several V
settings.
OUT
OUT
Type: Read-only
Default Value: 13h (Linear Mode, Exponent = -13)
Units: N/A
COMMAND
Format
VOUT_MODE (20h)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
1
0
0
1
1
MODE
Linear
BITS 7:5
000
BITS 4:0 (PARAMETER)
Five bit two’s complement exponent for the mantissa delivered as the data bytes for an output
voltage related command.
FN7558.3
September 14, 2015
Submit Document Feedback
31
ZL8800
VOUT_COMMAND (21h)
Definition: This command sets or reports the target output voltage. The integer value is multiplied by 2 raised to the power of -13h. This
command cannot be set to be higher than the lowest setting of either VOUT_MAX or 110% of the pin-strap V
setting.
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear -16 Unsigned
Type: R/W
Protectable: Yes
Default Value: Pin-strap setting
Units: Volts
Equation: V
-13
= VOUT_COMMAND × 2
OUT
Range: 0 to VOUT_MAX
Example: VOUT_COMMAND = 699Ah = 27,034
-13
Target voltage equals 27034 × 2
= 3.3V
COMMAND
Format
VOUT_COMMAND (21h)
Linear, unsigned binary
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Pin-strap setting
Default Value
VOUT_CAL_OFFSET (23h)
Definition: The VOUT_CAL_OFFSET command is used to apply a fixed offset voltage to the output voltage command value. This
command is typically used by the user to calibrate a device in the application circuit. The two bytes are formatted as a two’s
complement binary mantissa, used in conjunction with the exponent of -13h.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear -16 Signed
Type: R/W
Protectable: Yes
Default Value: 0000h
Units: Volts
Equation: V
-13
cal offset = VOUT_CAL_OFFSET×2
OUT
Range: ±3.99V
COMMAND
Format
VOUT_CAL_OFFSET (23h)
Linear-16 Signed
Bit Position
Access
15
R/W
0
14
R/W
0
13
R/W
0
12
R/W
0
11
R/W
0
10
R/W
0
9
R/W
0
8
R/W
0
7
R/W
0
6
R/W
0
5
R/W
0
4
R/W
0
3
R/W
0
2
R/W
0
1
R/W
0
0
R/W
0
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
32
ZL8800
VOUT_MAX (24h)
Definition: The VOUT_ MAX command sets an upper limit on the output voltage the unit can command regardless of any other
commands or combinations. The intent of this command is to provide a safeguard against a user accidentally setting the output
voltage to a possibly destructive level rather than to be the primary output overprotection. If a VOUT_COMMAND is sent with a value
higher than VOUT_MAX, the device will set the output voltage to VOUT_MAX.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear -16 Unsigned
Type: R/W
Protectable: Yes
Default Value: 1.10 x VOUT_COMMAND pin-strap setting
Units: Volts
Equation: V
-13
max = VOUT_MAX × 2
OUT
Range: 0V to 5.5V
COMMAND
Format
VOUT_MAX (24h)
Linear, unsigned binary
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
1.10 x VOUT_COMMAND Pin-strap Setting
Default Value
VOUT_MARGIN_HIGH (25h)
Definition: Sets the value of the V
which the output is to be changed when the OPERATION command is set to “Margin High”.
during a margin high. This VOUT_MARGIN_HIGH command loads the unit with the voltage to
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: R/W word
Protectable: Yes
Default Value: 1.05 x VOUT_COMMAND setting
Units: V
Equation: V
-13
margin high = VOUT_MARGIN_HIGH x 2
OUT
Range: 0V to VOUT_MAX
COMMAND
Format
VOUT_MARGIN_HIGH (25h)
Linear-16 Unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
1.05 x VOUT_COMMAND
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
33
ZL8800
VOUT_MARGIN_LOW (26h)
Definition: Sets the value of the V
the output is to be changed when the OPERATION command is set to “Margin Low”.
during a margin low. This VOUT_MARGIN_LOW command loads the unit with the voltage to which
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: R/W
Protectable: Yes
Default Value: 0.95 x VOUT_COMMAND pin-strap setting
Units: V
Equation: V
margin low = VOUT_MARGIN_LOW
OUT
Range: 0V to VOUT_MAX
COMMAND
Format
VOUT_MARGIN_LOW (26h)
Linear, two’s complement binary
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0.95 x VOUT_COMMAND
Default Value
VOUT_TRANSITION_RATE (27h)
Definition: This command sets the rate at which the output should change voltage when the device receives an OPERATION command
(Margin High, Margin Low) that causes the output voltage to change. The maximum possible positive value of the two data bytes
indicates that the device should make the transition as quickly as possible. This commanded rate does not apply when the device is
commanded to turn on or to turn off.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: BA00h (1.0V/ms)
Units: V/ms
N
Equation: VOUT_TRANSITION_RATE = Y×2
Range: 0.1 to 4V/ms
COMMAND
Format
VOUT_TRANSITION_RATE (27h)
Linear Data Format
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
34
ZL8800
VOUT_DROOP (28h)
Definition: The VOUT_DROOP sets the effective load line (V/I slope) for the rail in which the device is used. It is the rate, in mV/A at
which the output voltage decreases with increasing output current. For devices that are set to sink output current (negative output
current), the output voltage continues to increase as the output current is negative. VOUT_DROOP is not needed for 2-phase operation
with a single ZL8800.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0000h (0mV/A)
Units: mV/A
N
Equation: VOUT_DROOP = Y×2
Range: 0 to 40mV/A
COMMAND
Format
VOUT_DROOP (28h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
FREQUENCY_SWITCH (33h)
Definition: Sets the switching frequency of the device. Initial default value is defined by a pin-strap and this value can be overridden by
writing this command. If an external SYNC is utilized, this value should be set as close as possible to the external clock value. The
output must be disabled when writing this command. Available frequencies are defined by the equation f
11 ≤ n ≤ 80
= 16MHz/n where
SW
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: Pin-strap setting
Units: kHz
N
Equation: FREQUENCY_SWITCH = Y×2
Range: 200kHz to 1.33MHz
COMMAND
Format
FREQUENCY_SWITCH (33h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
Pin-strapped Value
FN7558.3
September 14, 2015
Submit Document Feedback
35
ZL8800
INTERLEAVE (37h)
Definition: Configures the phase offset of a device that is sharing a common SYNC clock with other devices. An INTERLEAVE group
number and desired phase position are specified. Interleave is used for setting the phase offset in noncurrent sharing devices. For
current sharing rails INTERLEAVE is ignored and DDC_CONFIG is used to configure the phase relationship between current sharing
phases.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: Set by pin-strapped PMBus™ address
Units: N/A
COMMAND
Format
INTERLEAVE (37h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
See Following Table
Function
Default Value
0
0
0
0
0
0
0
0
Four LSB’s of SMBus Address Four LSB’s of SMBus Address
BITS
15:8
7:4
PURPOSE
Not Used
VALUE
0
DESCRIPTION
Not Used
Group Number
0 to 15
Sets the group number. A value of 0 is interpreted as 16
Sets position of the device’s rail within the group. A value of 0 is interpreted as 16.
Position 1 will have a 22.5° offset.
3:0
Position of Device
0 to 15
IOUT_CAL_GAIN (38h)
Definition: Sets the effective impedance across the current sense circuit for use in calculating output current at +25°C.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: AA66h (0.3mΩ)
Units: mΩ
N
Equation: IOUT_CAL_GAIN = Y×2
COMMAND
Format
IOUT_CAL_GAIN (38h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
FN7558.3
September 14, 2015
Submit Document Feedback
36
ZL8800
IOUT_CAL_OFFSET (39h)
Definition: Used to null out any offsets in the output current sensing circuit, and to compensate for delayed measurements of current
ramp due to Isense blanking time.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0000h (0A)
Units: A
N
Equation: IOUT_CAL_OFFSET = Y×2
COMMAND
Format
IOUT_CAL_OFFSET (39h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
VOUT_OV_FAULT_LIMIT (40h)
Definition: Sets the V overvoltage fault threshold.
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: R/W
Protectable: Yes
Default Value: 1.15 x VOUT_COMMAND pin-strap setting
Units: V
-13
Equation: VOUT OV fault limit = VOUT_OV_FAULT_LIMIT×2
Range: 0V to 7.99V
COMMAND
Format
VOUT_OV_FAULT_LIMIT (40h)
Linear-16 Unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
1.15 x VOUT_COMMAND
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
37
ZL8800
VOUT_OV_FAULT_RESPONSE (41h)
Definition: Configures the V overvoltage fault response. Note that the device cannot be set to ignore this fault mode.The retry time is
OUT
the time between restart attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Shut down immediately, no retries)
Units: Retry time = 70ms
COMMAND
Format
VOUT_OV_FAULT_RESPONSE (41h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: the device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
7:6
Output is disabled while the fault is present. Operation resumes and the output is enabled when
the fault condition no longer exists.
11
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the device is restarted.
001-110 Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
5:3
2:0
Retry Setting
Not Used
111
commanded OFF (by the CONTROL pin or OPERATION command or both), bias power is
removed, or another fault condition causes the unit to shut down.
000-111 Not Used
VOUT_UV_FAULT_LIMIT (44h)
Definition: Sets the V
device is disabled.
undervoltage fault threshold. This fault is masked during ramp, before power-good is asserted or when the
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: R/W
Protectable: Yes
Default Value: 0.85 x VOUT_COMMAND pin-strap setting
Units: V
-13
Equation: VOUT UV fault limit = VOUT_UV_FAULT_LIMIT×2
Range: 0V to 7.99V
COMMAND
Format
VOUT_UV_FAULT_LIMIT (44h)
Linear-16 unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0.85 x VOUT_COMMAND
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
38
ZL8800
VOUT_UV_FAULT_RESPONSE (45h)
Definition: Configures the V undervoltage fault response. Note that VOUT UV faults can only occur after Power-good (PG) has been
OUT
asserted. Under some circumstances this will cause the output to stay fixed below the power good threshold indefinitely. If this behavior
is undesired, use setting 80h. The retry time is the time between restart attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Shut down immediately, no retries)
Units: Retry time unit = 70ms
COMMAND
VOUT_UV_FAULT_RESPONSE (45h)
Bit Field
Format
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: the device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
7:6
11
Not Used
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the ENABLE pin or OPERATION command or both), bias power is removed,
or another fault condition causes the unit to shut down.
111
000-111 Not Used
IOUT_OC_FAULT_LIMIT (46h)
Definition: Sets the I peak overcurrent fault threshold. This limit is applied to current measurement samples taken after the Current
OUT
Sense Blanking Time has expired. A fault occurs after this limit is exceeded for the number of consecutive samples as defined in
ISENSE_CONFIG. This feature shares the OC fault bit operation (in STATUS_IOUT) and OC fault response with IOUT_AVG_OC_FAULT_LIMIT.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: DA80h (20A)
Units: A
N
Equation: IOUT_OC_FAULT_LIMIT = Y×2
Range: -100A to 100A
COMMAND
Format
IOUT_OC_FAULT_LIMIT (46h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
1
1
0
1
0
1
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
39
ZL8800
IOUT_UC_FAULT_LIMIT (4Bh)
Definition: Sets the I valley undercurrent fault threshold. This limit is applied to current measurement samples taken after the Current
OUT
Sense Blanking Time has expired. A fault occurs after this limit is exceeded for the number of consecutive sample as defined in
ISENSE_CONFIG. This feature shares the UC fault bit operation (in STATUS_IOUT) and UC fault response with IOUT_AVG_UC_FAULT_LIMIT.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: -1 x IOUT_OC_FAULT_LIMIT
Units: A
N
Equation: IOUT_OC_FAULT_LIMIT = Y×2
Range: -100A to 100A
COMMAND
Format
IOUT_UC_FAULT_LIMIT (4Bh)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
-1 x IOUT_OC_FAULT_LIMIT
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
OT_FAULT_LIMIT (4Fh)
Definition: The OT_FAULT_LIMIT command sets the temperature at which the device should indicate an over-temperature fault. Note
that the temperature must drop below OT_WARN_LIMIT to clear this fault.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: EBE8h (+125˚C)
Units: Celsius
N
Equation: OT_FAULT_LIMIT = Y×2
Range: 0 to +175
COMMAND
Format
OT_FAULT_LIMIT (4Fh)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
1
0
1
0
1
1
1
1
1
0
1
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
40
ZL8800
OT_FAULT_RESPONSE (50h)
Definition: The OT_FAULT_RESPONSE command instructs the device on what action to take in response to an over-temperature fault.
The retry time is the time between restart attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 80h (Shut down immediately, no retries)
Units: Retry time unit = 210ms
COMMAND
Format
OT_FAULT_RESPONSE (50h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: The device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
Output is disabled while the fault is present. Operation resumes and the output is enabled when
the fault condition no longer exists.
11
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or
another fault condition causes the unit to shut down.
111
000-111 Not Used
OT_WARN_LIMIT (51h)
Definition: The OT_WARN_LIMIT command sets the temperature at which the device should indicate an over-temperature warning
alarm. In response to the OT_WARN_LIMIT being exceeded, the device: Sets the TEMPERATURE bit in STATUS_WORD, Sets the
OT_WARNING bit in STATUS_TEMPERATURE, and notifies the host.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: EB70h (+110°C)
Units: Celsius
N
Equation: OT_WARN_LIMIT = Y×2
Range: 0 to 175
COMMAND
Format
OT_WARN_LIMIT (51h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
1
0
1
0
1
1
0
1
1
1
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
41
ZL8800
UT_WARN_LIMIT (52h)
Definition: The UT_WARN_LIMIT command set the temperature at which the device should indicate an under-temperature Warning
alarm. In response to the UT_WARN_LIMIT being exceeded, the device: Sets the TEMPERATURE bit in STATUS_WORD, Sets the
UT_WARNING bit in STATUS_TEMPERATURE, and notifies the host.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: DC40h (-30°C)
Units: Celsius
N
Equation: UT_WARN_LIMIT = Y×2
Range: -55 to +25
COMMAND
Format
UT_WARN_LIMIT (52h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
1
1
1
0
0
0
1
0
0
0
0
0
0
UT_FAULT_LIMIT (53h)
Definition: The UT_FAULT_LIMIT command sets the temperature, in degrees Celsius, of the unit at which it should indicate an under-
temperature fault. Note that the temperature must rise above UT_WARN_LIMIT to clear this fault.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: E530h (-45°C)
Units: Celsius
N
Equation: UT_FAULT_LIMIT = Y×2
Range: -55 to +25
COMMAND
Format
UT_FAULT_LIMIT (53h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
1
0
0
1
0
1
0
0
1
1
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
42
ZL8800
UT_FAULT_RESPONSE (54h)
Definition: Configures the under-temperature fault response as defined by the table below. The retry time is the time between restart
attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Shut down immediately, no retries)
Units: Retry time unit = 210ms
COMMAND
Format
UT_FAULT_RESPONSE (54h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: The device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
Output is disabled while the fault is present. Operation resumes and the output is enabled when
the fault condition no longer exists.
11
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the device is restarted.
001-110 Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
5:3
2:0
Retry Setting
Not Used
111
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or
another fault condition causes the unit to shut down.
000-111 Not Used
VIN_OV_FAULT_LIMIT (55h)
Definition: Sets the V overvoltage fault threshold.
IN
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: D380h (14V)
Units: V
N
Equation: VIN_OV_FAULT_LIMIT = Y×2
Range: 0 to 19V
COMMAND
Format
VIN_OV_FAULT_LIMIT (55h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
1
0
0
1
1
1
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
43
ZL8800
VIN_OV_FAULT_RESPONSE (56h)
Definition: Configures the V overvoltage fault response as defined by the table below. The retry time is the time between restart
IN
attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate shutdown, no retry)
Units: Retry time unit = 70ms
COMMAND
Format
VIN_OV_FAULT_RESPONSE (56h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: The device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
Output is disabled while the fault is present. Operation resumes and the output is enabled when
the fault condition no longer exists.
11
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or
another fault condition causes the unit to shut down.
111
000-111 Not Used
VIN_OV_WARN_LIMIT (57h)
Definition: Sets the V overvoltage warning threshold as defined by the table below. In response to the OV_WARN_LIMIT being
IN
exceeded, the device: Sets the NONE OF THE ABOVE and INPUT bits in STATUS_WORD, Sets the VIN_OV_WARNING bit in STATUS_INPUT,
and notifies the host.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: D360h (13.5V)
Units: V
N
Equation: VIN_OV_FAULT_LIMIT = Y×2
Range: 0 to 19V
COMMAND
Format
VIN_OV_WARN_LIMIT (57h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
1
0
0
1
1
0
1
1
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
44
ZL8800
VIN_UV_WARN_LIMIT (58h)
Definition: Sets the V undervoltage warning threshold. If a VIN_UV_FAULT occurs, the input voltage must rise above
IN
VIN_UV_WARN_LIMIT to clear the fault, which provides hysteresis to the fault threshold. In response to the UV_WARN_LIMIT being
exceeded, the device: Sets the NONE OF THE ABOVE and INPUT bits in STATUS_WORD, Sets the VIN_UV_WARNING bit in STATUS_INPUT,
and notifies the host.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 1.03 x VIN_UV_FAULT_LIMIT pin-strap setting
Units: V
N
Equation: VIN_UV_WARN_LIMIT = Y×2
Range: 0 to 19V
COMMAND
Format
VIN_UV_WARN_LIMIT (58h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
1.03 x VIN_UV_FAULT_LIMIT
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
VIN_UV_FAULT_LIMIT (59h)
Definition: Sets the V undervoltage fault threshold.
IN
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: Pin-strap setting
Units: V
N
Equation: VIN_UV_FAULT_LIMIT = Y×2
Range: 0 to 19V
COMMAND
Format
VIN_UV_FAULT_LIMIT (59h)
Linear, two’s complement binary
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
Pin-Strapped Value
FN7558.3
September 14, 2015
Submit Document Feedback
45
ZL8800
VIN_UV_FAULT_RESPONSE (5Ah)
Definition: Configures the V undervoltage fault response as defined by the table below. The retry time is the time between restart
IN
attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate shutdown, no retries)
Units: Retry time unit = 70ms
COMMAND
Format
VIN_UV_FAULT_RESPONSE (5Ah)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
00-01
10
DESCRIPTION
Response Behavior: The device:
• Pulls SALRT low
Not Used
Disable and Retry according to the setting in bits [5:3].
• Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
Output is disabled while the fault is present. Operation resumes and the output is enabled when
the fault condition no longer exists.
11
CLEAR_FAULTS command.
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
5:3
2:0
Retry Setting
Not Used
111
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or
another fault condition causes the unit to shut down.
000-111 Not Used
POWER_GOOD_ON (5Eh)
Definition: Sets the voltage threshold for power-good indication. Power-good asserts when the output voltage exceeds
POWER_GOOD_ON and de-asserts when the output voltage is less than VOUT_UV_FAULT_LIMIT.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: R/W
Protectable: Yes
Default Value: 0.9 x VOUT_COMMAND pin-strap setting
Units: V
COMMAND
Format
POWER_GOOD_ON (5Eh)
Linear, unsigned binary
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0.9 x VOUT_COMMAND
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
46
ZL8800
TON_DELAY (60h)
Definition: Sets the delay time from when the device is enabled to the start of V
rise.
OUT
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: CA80h, 5ms
Units: ms
N
Equation: TON_DELAY = Y×2
Range: 0 to 5 seconds. The minimum delay time is 3ms. Values below 3ms will result in a delay time of 3ms.
COMMAND
Format
TON_DELAY (60h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
0
1
0
1
0
1
0
0
0
0
0
0
0
TON_RISE (61h)
Definition: Sets the rise time of VOUT after ENABLE and TON_DELAY.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: CA80h, 5ms
Units: ms
N
Equation: TON_RISE = Y×2
Range: 1 to 100ms. The minimum rise time is 1ms. Values below 1ms will default to 1ms. Short rise times may cause excessive input
and output currents to flow, thus triggering overcurrent faults at start-up.
COMMAND
Format
TON_RISE (61h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1
1
0
0
1
0
1
0
1
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
47
ZL8800
TOFF_DELAY (64h)
Definition: Sets the delay time from DISABLE to start of VOUT fall.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0000h, 0ms
Units: ms
N
Equation: TON_DELAY = Y×2
Range: 0 to 5 seconds. Values less than 0.5ms will set the device to immediate off (no TOFF_FALL ramp down).
COMMAND
Format
TOFF_DELAY (64h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
TOFF_FALL (65h)
Definition: Sets the fall time for V
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
after DISABLE and TOFF_DELAY.
OUT
Protectable: Yes
Default Value: 1 x TON_RISE
Units: ms
N
Equation: TOFF_FALL = Y×2
Range: 0 to 100ms. Although values can be set below 0.50ms, fall time accuracy cannot be guaranteed. In addition, short fall times
may cause excessive negative output current to flow, thus triggering undercurrent faults at shut-down.
COMMAND
Format
TOFF_FALL (65h)
Linear, two’s complement binary
Bit Position
Access
15
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Signed Exponent, N Signed Mantissa, Y
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
Default Value
1 x TON_RISE
STATUS_BYTE (78h)
Definition: The STATUS_WORD command returns two bytes of information with a summary of the unit’s fault condition. Based on the
information in these bytes, the host can get more information by reading the appropriate status registers. The low byte of the
STATUS_WORD is the same register as the STATUS_BYTE (78h) command.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
48
ZL8800
STATUS_WORD (79h)
Definition: The STATUS_WORD command returns two bytes of information with a summary of the unit’s fault condition. Based on the
information in these bytes, the host can get more information by reading the appropriate status registers. The low byte of the
STATUS_WORD is the same register as the STATUS_BYTE (78h) command.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 0000h
Units: N/A
COMMAND
Format
STATUS_WORD (79h)
Bit Field
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BIT NUMBER
STATUS BIT NAME
MEANING
15
14
VOUT
IOUT
An output voltage fault or warning has occurred.
An output current or output power fault or warning has occurred.
An input voltage, input current, or input power fault or warning has
occurred.
13
INPUT
12
11
10
9
MFG_SPECIFIC
POWER_GOOD #
NOT USED
A manufacturer specific fault or warning has occurred.
The POWER_GOOD signal, if present, is negated. (Note 17)
Not Used
OTHER
A bit in STATUS_OTHER is set.
A fault type not given in bits 15:1 of the STATUS_WORD has been
detected.
8
7
6
UNKNOWN
BUSY
A fault was declared because the device was busy and unable to
respond.
This bit is asserted if the unit is not providing power to the output,
regardless of the reason, including simply not being enabled.
OFF
5
4
3
2
1
0
VOUT_OV_FAULT
IOUT_OC_FAULT
VIN_UV_FAULT
TEMPERATURE
CML
An output overvoltage fault has occurred.
An output overcurrent fault has occurred.
An input undervoltage fault has occurred.
A temperature fault or warning has occurred.
A communications, memory or logic fault has occurred.
A fault or warning not listed in bits 7:1 has occurred.
NONE OF THE ABOVE
NOTE:
17. If the POWER_GOOD# bit is set, this indicates that the POWER_GOOD signal, if present, is signaling that the output power is not good.
FN7558.3
September 14, 2015
Submit Document Feedback
49
ZL8800
STATUS_VOUT (7Ah)
Definition: The STATUS_VOUT command returns one data byte with the status of the output voltage.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_VOUT (7Ah)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT NUMBER
STATUS BIT NAME
VOUT_OV_FAULT
VOUT_OV_WARNING
VOUT_UV_WARNING
VOUT_UV_FAULT
Not Used
MEANING
7
6
Indicates an output overvoltage fault.
Indicates an output overvoltage warning.
Indicates an output undervoltage warning.
Indicates an output undervoltage fault.
Not Used
5
4
3:0
STATUS_IOUT (7Bh)
Definition: The STATUS_IOUT command returns one data byte with the status of the output current.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_IOUT (7Bh)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT NUMBER
STATUS BIT NAME
IOUT_OC_FAULT
IOUT_OC_LV_FAULT
IOUT_OC_WARNING
IOUT_UC_FAULT
Not Used
MEANING
7
6
An output overcurrent fault has occurred.
An output overcurrent and low voltage fault has occurred.
An output overcurrent warning has occurred.
An output under current fault has occurred.
Not Used
5
4
3:0
FN7558.3
September 14, 2015
Submit Document Feedback
50
ZL8800
STATUS_INPUT (7Ch)
Definition: The STATUS_INPUT command returns input voltage and input current status information.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_INPUT (7Ch)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT NUMBER
STATUS BIT NAME
VIN_OV_FAULT
VIN_OV_WARNING
VIN_UV_WARNING
VIN_UV_FAULT
Not Used
MEANING
7
6
An input overvoltage fault has occurred.
An input overvoltage warning has occurred.
An input undervoltage warning has occurred.
An input undervoltage fault has occurred.
Not Used
5
4
3:0
STATUS_TEMPERATURE (7Dh)
Definition: The STATUS_TEMPERATURE command returns one byte of information with a summary of any temperature related faults or
warnings.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_TEMP (7Dh)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT NUMBER
STATUS BIT NAME
OT_FAULT
MEANING
7
6
An over-temperature fault has occurred.
An over-temperature warning has occurred.
An under-temperature warning has occurred.
An under-temperature fault has occurred.
Not Used
OT_WARNING
UT_WARNING
UT_FAULT
5
4
3:0
Not Used
FN7558.3
September 14, 2015
Submit Document Feedback
51
ZL8800
STATUS_CML (7Eh)
Definition: The STATUS_WORD command returns one byte of information with a summary of any Communications, Logic and/or
Memory errors.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read-only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_CML (7Eh)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT NUMBER
MEANING
7
6
Invalid or unsupported PMBus™ command was received.
The PMBus™ command was sent with invalid or unsupported data.
A packet error was detected in the PMBus™ command.
Not Used
5
4:2
A PMBus™ command tried to write to a read-only or protected command, or a communication fault other than the ones listed in
this table has occurred.
1
0
Not Used
STATUS_MFR_SPECIFIC (80h)
Definition: The STATUS_MFR_SPECIFIC command returns one byte of information providing the status of the device’s voltage
monitoring and clock synchronization faults. Note: The VMON OV/UV warnings are set at ±10% of the VMON_XX_FAULT commands.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read only
Protectable: No
Default Value: 00h
Units: N/A
COMMAND
Format
STATUS_MFR_SPECIFIC (80h)
Bit Field
Bit Position
Access
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT
7:6
5
FIELD NAME
MEANING
Not Used
Not Used
VMON UV Warning
VMON OV Warning
The voltage on the VMON pin has dropped 10% below the level set by MFR_VMON_UV_FAULT
The voltage on the VMON pin has risen 10% above the level set by MFR_VMON_OV_FAULT
4
3
External Switching Period Fault Loss of external clock synchronization has occurred
2
Not Used
Not Used
1
VMON UV Fault
VMON OV Fault
The voltage on the VMON pin has dropped below the level set by MFR_VMON_UV_FAULT
The voltage on the VMON pin has risen above the level set by MFR_VMON_OV_FAULT
0
FN7558.3
September 14, 2015
Submit Document Feedback
52
ZL8800
READ_VIN (88h)
Definition: Returns the input voltage reading.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: V
N
Equation: READ_VIN = Y×2
Range: N/A
COMMAND
Format
READ_VIN (88h)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
READ_IIN (89h)
Definition: Returns the input current reading.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: A
N
Equation: READ_IIN = Y×2
Range: N/A
COMMAND
Format
READ_IIN (89h)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
9
R
8
R
7
R
6
5
R
4
R
3
R
2
R
1
R
0
R
R
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
Default Value N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
READ_VOUT (8Bh)
Definition: Returns the output voltage reading.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-16 Unsigned.
Type: Read-only
Protectable: No
Default Value: N/A
-13
Equation: READ_VOUT = READ_VOUT × 2
Units: V
COMMAND
Format
READ_VOUT (8Bh)
Linear-16 Unsigned
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
R
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
FN7558.3
September 14, 2015
Submit Document Feedback
53
ZL8800
READ_IOUT (8Ch)
Definition: Returns the output current reading.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: A
Equation: READ_IOUT = Y×2
N
Range: N/A
COMMAND
Format
READ_IOUT (8Ch)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
READ_TEMPERATURE_1 (8Dh)
Definition: Returns the temperature reading internal to the device.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: ˚C
Equation: READ_TEMPERATURE_1 = Y×2
N
Range: N/A
COMMAND
Format
READ_INTERNAL_TEMP (8Dh)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
N/A N/A N/A
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
READ_TEMPERATURE_2 (8Eh)
Definition: Returns the temperature reading from the external temperature device connected to XTEMP.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read-only
Protectable: No
Default Value: N/A
Units: ˚C
Equation: READ_TEMPERATURE_2 = Y×2
N
Range: N/A
COMMAND
Format
READ_EXTERNAL_TEMP (8Eh)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
N/A N/A N/A
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
FN7558.3
September 14, 2015
Submit Document Feedback
54
ZL8800
READ_DUTY_CYCLE (94h)
Definition: Reports the actual duty cycle of the converter during the enable state.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read only
Protectable: No
Default Value: N/A
Units: %
N
Equation: READ_DUTY_CYCLE = Y×2
Range: 0 to100%
COMMAND
Format
READ_DUTY_CYCLE (94h)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
READ_FREQUENCY (95h)
Definition: Reports the actual switching frequency of the converter during the enable state.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Default Value: N/A
Units: kHz
N
Equation: READ_FREQUENCY = Y×2
Range: N/A
COMMAND
Format
READ_FREQUENCY (95h)
Linear-11
Bit Position
Access
15
R
14
R
13
R
12
R
11
R
10
R
9
R
8
R
7
R
6
R
5
R
4
R
3
R
2
R
1
R
0
R
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
N/A N/A N/A
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
MFR_ID (99h)
Definition: MFR_ID sets a user defined identification string not to exceed 32 bytes. The sum total of characters in MFR_ID,
MFR_MODEL, MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot
exceed 128 bytes. This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform
a RESTORE, write this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: user defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
55
ZL8800
MFR_MODEL (9Ah)
Definition: MFR_MODEL sets a user defined model string not to exceed 32 bytes. The sum total of characters in MFR_ID, MFR_MODEL,
MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 bytes.
This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write
this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: user defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
MFR_REVISION (9Bh)
Definition: MFR_REVISION sets a user defined revision string not to exceed 32 bytes. The sum total of characters in MFR_ID,
MFR_MODEL, MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot
exceed 128 bytes. This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform
a RESTORE, write this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: user defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
MFR_LOCATION (9Ch)
Definition: MFR_LOCATION sets a user defined location identifier string not to exceed 32 bytes. The sum total of characters in MFR_ID,
MFR_MODEL, MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot
exceed 128 bytes. This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform
a RESTORE, write this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: user defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
MFR_DATE (9Dh)
Definition: MFR_DATE sets a user defined date string not to exceed 32 bytes. The sum total of characters in MFR_ID, MFR_MODEL,
MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 bytes.
This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write
this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: user defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
56
ZL8800
MFR_SERIAL (9Eh)
Definition: MFR_SERIAL sets a user defined serialized identifier string not to exceed 32 bytes. The sum total of characters in MFR_ID,
MFR_MODEL, MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot
exceed 128 bytes. This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform
a RESTORE, write this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: User defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
IC_DEVICE_ID (ADh)
Definition: Reports device identification information.
Data Length in Bytes: 4
Data Format: CUS
Type: Block Read
Protectable: No
Default Value: 49A02400h
Units: N/A
COMMAND
Format
IC_DEVICE_ID (ADh)
Block Read
Byte Position
Function
3
2
1
0
MFR code
49h
ID High Byte
A0h
ID Low Byte
24h
Reserved
00h
Default Value
IC_DEVICE_REV (AEh)
Definition: Reports device revision information.
Data Length in Bytes: 4
Data Format: CUS
Type: Block Read
Protectable: No
Default Value: 00000000h
Units: N/A
COMMAND
Format
IC_DEVICE_REV (AEh)
Block Read
Byte Position
3
2
1
0
Function
Firmware Major
00h
Firmware Minor
00h
Factory Configuration
00h
Reserved
00h
Default Value
USER_DATA_00 (B0h)
Definition: USER_DATA_00 sets a user defined data string not to exceed 32 bytes. The sum total of characters in MFR_ID, MFR_MODEL,
MFR_REVISION, MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 bytes
This limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write
this command then perform a STORE/RESTORE.
Paged or Global: Global
Data Length in Bytes: User defined
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: Yes
Default Value: null
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
57
ZL8800
DEADTIME_MAX (BFh)
Definition: Sets the maximum dead time value for the PWMH and PWML outputs. This limit applies during frozen or adaptive dead time
algorithm modes (see DEADTIME_CONFIG).
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 3838h (56ns/56ns)
Units: ns
Range: 0 to 60ns
Reference: N/A
COMMAND
Format
DEADTIME_MAX (BFh)
Bit Field/Linear-7 Unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
1
1
1
0
0
0
0
0
1
1
1
0
0
0
BITS
15
PURPOSE
Not Used
VALUE
DESCRIPTION
0
H
0
L
Not Used
Limits the maximum allowed HIGH to LOW dead time when using the
adaptive dead time algorithm. dead time = Hns (signed)
14:8
7
Sets the maximum HIGH to LOW dead time
Not Used
Not Used
Limits the maximum allowed LOW to HIGH dead time when using the
adaptive dead time algorithm. dead time = Lns (signed)
6:0
Sets the maximum LOW to HIGH dead time
ISENSE_CONFIG (D0h)
Definition: Configures current sense circuitry.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W word
Protectable: Yes
Default Value: 4204h (256ns, 5 counts, downslope, low range)
Units: N/A
Range: N/A
COMMAND
Format
ISENSE_CONFIG (D0h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
1
0
0
0
0
1
0
0
0
0
0
0
1
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
58
ZL8800
BIT
FIELD NAME
VALUE
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
11001
11010
000
SETTING
DESCRIPTION
0
32
64
96
128
160
192
224
256
288
320
352
384
Current Sense Blanking
Time
15:11
416
Sets the blanking time current sense blanking time in increments of 32ns
448
480
512
544
576
608
640
672
704
736
768
800
832
1
001
3
010
5
7
Sets the number of consecutive overcurrent (OC) or undercurrent (UC) events
required for a fault. An event can occur once during each switching cycle. For
example, if 5 is selected, an OC or UC event must occur for 5 consecutive
switching cycles, resulting in a delay of at least 5 switching periods.
011
10:8 Current Sense Fault Count
100
9
101
11
110
13
111
15
7:4
3:2
Not Used
0000
00
Not Used
Not Used
DCR (Down Slope)
DCR (Up Slope)
Not Used
Low Range
Medium Range
High Range
Not Used
Not Used
01
Current Sense Control
Selection of current sensing method (DCR based: VOUT referenced)
10
11
00
01
1:0
Current Sense Range
Low Range ±25mV, Medium Range ±35mV, High Range ±50mV
10
11
FN7558.3
September 14, 2015
Submit Document Feedback
59
ZL8800
USER_CONFIG (D1h)
Definition: Configures several user-level features. This command should be saved immediately after being written to the desired user or
default store. This is recommended when written as an individual command or as part of a series of commands in a configuration file
or script.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 0402h
Units: N/A
COMMAND
Format
USER_CONFIG (D1h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
1
0
0
0
0
0
0
0
0
1
0
BIT
FIELD NAME
VALUE
SETTING
0-31d
DESCRIPTION
15:11 Minimum Duty Cycle 00000
Sets the minimum duty-cycle to 2 x (VALUE + 1)/512. Must be enabled with Bit 7
0 = PWML and PWMH are direct drive to MOSFET driver
1 = PWML is DRMOS Enable, PWMH is DRMOS PWM input
Not Used
0
Disable
Enable
Not Used
Disable
Enable
Not Used
VSET0
10
9:8
7
Enable DR MOS
Not Used
1
0
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
Minimum Duty Cycle
Control
Control for minimum duty cycle
6
Not Used
Not Used
0 = Uses only VSET0 to set Pin-strapped output voltage
1 = Uses only VSET1 to set Pin-strapped output voltage
5
VSET Select
VSET1
Disable
Enable
4
3
2
1
0
Margin Ratio Enable
PWML disabled state
Use VOUT_MARGIN_RATIO to program margin values when enabled
Low when disabled
High when disabled
Open Drain
Push-pull
PWML is low (off) when device is disabled (Bit 3 set to 0), or high (on) when device
is disabled (Bit 3 set to 1)
0 = PG is open-drain output
1 = PG is push-pull output
Power-good
Configuration
Disable
XTEMP Enable
Enable external temperature sensor
Enable
Disable
XTEMP Fault Select
Selects external temperature sensor to determine temperature faults
Enable
FN7558.3
September 14, 2015
Submit Document Feedback
60
ZL8800
IIN_CAL_GAIN (D2h)
Definition: Sets the effective impedance across the current sense circuit for use in calculating input current at +25°C.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: C200h (2mΩ)
Units: mΩ
N
Equation: IIN_CAL_GAIN = Y×2
COMMAND
Format
IIN_CAL_GAIN (D2h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
DDC_CONFIG (D3h)
Definition: Configures DDC addressing and current sharing. To operate as a 2-phase controller, set both phases to the same Rail ID, set
Phases in Rail to 2, then set each phase ID sequentially as 0 and 1. The ZL8800 will automatically equally offset the phases in the rail.
Phase spreading is done automatically as part of the DDC_CONFIG command, the INTERLEAVE command only applies to non-current
sharing rails. The ZL8800 can operate as a 2-phase controller, current sharing between it’s 2 internal phases, but does not support
current sharing with other ZL8800 devices or phases.
NOTE: The output MUST be connected to VSEN0P and VSEN0N when operating as a 2-phase controller.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: PMBus™ address pin-strap dependent.
Units: N/A
COMMAND
Format
DDC_CONFIG (D3h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
Lower 5 bits of device address
0
0
0
0
0
0
0
0
BIT
15:13
12:8
7:3
FIELD NAME
Phase ID
VALUE
0 to 7
SETTING
DESCRIPTION
0
0
Sets the output's phase position within the rail
Rail ID
0 to 31d
00
Identifies the device as part of a current sharing rail (Shared output)
Not Used
Not Used
00
0
2:0
Phases In Rail
0 to 7
Identifies the number of phases on the same rail (+1)
FN7558.3
September 14, 2015
Submit Document Feedback
61
ZL8800
POWER_GOOD_DELAY (D4h)
Definition: Sets the delay applied between the output exceeding the PG threshold (POWER_GOOD_ON) and asserting the PG pin. The
delay time can range from 0ms up to 500s, in steps of 125ns. A 1ms minimum configured value is recommended to apply proper
debounce to this signal.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: BA00h, 1ms
Units: ms
N
Equation: POWER_GOOD_DELAY = Y×2
Range: 0 t0 5 seconds
COMMAND
Format
POWER_GOOD_DELAY (D4h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
INDUCTOR (D6h)
Definition: Informs the device of the circuit’s inductor value. This is used in adaptive algorithm calculations relating to the inductor
ripple current.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: B23Dh (0.56µH)
Units: µH
N
Equation: INDUCTOR = Y×2
Range: 0 to 100µH
COMMAND
Format
INDUCTOR (D6h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
0
1
1
0
0
1
0
0
0
1
1
1
1
0
1
FN7558.3
September 14, 2015
Submit Document Feedback
62
ZL8800
VOUT_MARGIN RATIO (D7h)
Definition: Percentage to set MARGIN_HIGH and MARGIN_LOW above and below VOUT_COMMAND when feature is enabled by
USER_CONFIG.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11
Type: R/W
Protectable: Yes
Default Value: 5 (CA80h)
Units: %
N
Equation: VOUT_MARGIN_RATIO = Y×2
Range: 0 to 50%
COMMAND
Format
VOUT_MARGIN_RATIO (D7h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
1
0
0
1
0
1
0
1
0
0
0
0
0
0
0
OVUV_CONFIG (D8h)
Definition: Configures the output voltage OV and UV fault detection feature
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 00h
Units: N/A
COMMAND
Format
OVUV_CONFIG (D8h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BITS
7
PURPOSE
VALUE
0
DESCRIPTION
Controls how an OV fault response shutdown sets the output
driver state
An OV fault does not enable low-side power device
An OV fault enables the low-side power device
Not Used
1
0
6:4 Not Used
Defines the number of consecutive limit violations required to
declare an OV or UV fault
3:0
N
N+1 consecutive OV or UV violations initiate a fault response
FN7558.3
September 14, 2015
Submit Document Feedback
63
ZL8800
XTEMP_SCALE (D9h)
Definition: Sets a scalar value that is used for calibrating the external temperature. The constant is applied in the equation below to
produce the read value of XTEMP via the PMBus™ command READ_EXTERNAL_TEMP.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: BA00h (1.0)
Units: 1/°C
1
Equation:
READ_TEMPERATURE_2 ExternalTemperature
XTEMP_OFFSET
XTEMP_SCALE
Range: 0.1 to 10
COMMAND
Format
XTEMP_SCALE (D9h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
XTEMP_OFFSET (DAh)
Definition: Sets an offset value that is used for calibrating the external temperature. The constant is applied in the equation below to
produce the read value of XTEMP via the PMBus™ command READ_EXTERNAL_TEMP.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0000h (0)
Units: °C
1
Equation:
READ_TEMPERATURE_2 ExternalTemperature
XTEMP_OFFSET
XTEMP_SCALE
Range: -100 to 100
COMMAND
Format
XTEMP_OFFSET (DAh)
Linear-11
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Access
Function
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Signed Exponent, N
Signed Mantissa, Y
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
64
ZL8800
TEMPCO_CONFIG (DCh)
Definition: Configures the correction factor and temperature measurement source when performing temperature coefficient correction
for current sense. TEMPCO_CONFIG values are applied as negative correction to a positive temperature coefficient.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 27h (3900ppm/°C)
Equation: To determine the hex value of the Tempco Correction factor (TC) for current scale of a power stage current sensing, first
determine the temperature coefficient of resistance for the sensing element, α. This is found with the equation:
RREF R
RREF (TREF T )
Where:
R = Sensing element resistance at temperature “T”
R
= Sensing element resistance at reference temperature T
REF
REF
α = Temperature coefficient of resistance for the sensing element material
T = Temperature measured by temperature sensor, in Degrees Celsius
T
= Reference temperature that α is specified at for the sensing element material
REF
After α is determined, convert the value in units of 100ppm/°C. This value is then converted to a hex value with the following equation:
106
100
TC
Typical Values: Copper = 3900ppm/˚C (27h), silicon = 4800ppm/˚C (30h)
Range: 0 to 6300ppm/˚C
COMMAND
Format
TEMPCO_CONFIG (DCh)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
1
0
0
1
1
1
BITS
7
PURPOSE
VALUE
0
DESCRIPTION
Selects the temp sensor source for tempco correction
Selects the internal temperature sensor
Selects the XTEMP pin for temperature measurements (2N3904 Junction)
Note that XTEMP must be enabled in USER_CONFIG, bit 1.
1
Sets the tempco correction in units of 100ppm/˚C for
IOUT_CAL_GAIN
RSEN (DCR) = IOUT_CAL_GAIN x (1+TC x (T-25))
where RSEN = resistance of sense element
6:0
TC
FN7558.3
September 14, 2015
Submit Document Feedback
65
ZL8800
DEADTIME (DDh)
Definition: Sets the nonoverlap between PWM transitions using a 2-byte data field. The most significant byte controls the high-side to
low-side dead time value as a single 2’s-complement signed value in units of ns. The least-significant byte controls the low-side to
high-side dead time value. Positive values imply a non-overlap of the FET drive on-times. Negative values imply an overlap of the FET
drive on-times. The device will operate at the dead time values written to this command when adaptive dead time is disabled, between
the minimum dead time specified in DEADTIME_CONFIG and the maximum dead time specified in DEADTIME_MAX. When switching
from adaptive dead time mode to frozen mode (by writing to Bit 15 of DEADTIME_CONFIG) the frozen dead time will be whatever the
last dead time was before the device switches to frozen dead time mode.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Two 2’s complement bytes
Type: R/W
Protectable: Yes
Default Value: 1010h (16ns/16ns)
Units: ns
Range: -15ns to 60ns
COMMAND
Format
DEADTIME (DDh)
Linear-8 Signed
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
High to low-side dead time 8 bit two's complement signed
Low to high-side dead time 8 bit two's complement signed
Default Value
0
0
0
1
0
0
0
0
0
0
0
1
0
0
0
0
DEADTIME_CONFIG (DEh)
Definition: Configures the adaptive dead time optimization mode. Also sets the minimum dead time value for the adaptive dead time
mode range.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 0808h (Adaptive dead time control, 8ns/8ns minimum dead time)
Units: N/A
COMMAND
Format
DEADTIME_CONFIG (DEh)
Bit Field/Linear-7 Unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
1
0
0
0
0
0
0
0
1
0
0
0
BITS
15
PURPOSE
VALUE
DESCRIPTION
0
1
Adaptive HIGH to LOW dead time control
Freeze the HIGH to LOW dead time
Sets the HIGH to LOW transition dead time mode
Sets the minimum HIGH to LOW dead time
Sets the LOW to HIGH transition dead time mode
Sets the minimum LOW to HIGH dead time
Limits the minimum allowed HIGH to LOW dead time when using
the adaptive dead time algorithm (2ns resolution)
14:8
7
0-126d
0
1
Adaptive LOW to HIGH dead time control
Freeze the LOW to HIGH dead time
Limits the minimum allowed LOW to HIGH dead time when using
the adaptive dead time algorithm (2ns resolution)
6:0
0-126d
FN7558.3
September 14, 2015
Submit Document Feedback
66
ZL8800
ASCR_CONFIG (DFh)
Definition: Allows user configuration of ASCR settings. ASCR gain and residual value are automatically set by the ZL8800 based on
input voltage and output voltage. ASCR Gain is analogous to bandwidth, ASCR Residual is analogous to damping. To improve load
transient response performance, increase ASCR Gain. To lower transient response overshoot, increase ASCR Residual. Increasing ASCR
gain can result in increased PWM jitter and should be evaluated in the application circuit. Excessive ASCR gain can lead to excessive
output voltage ripple. Increasing ASCR Residual to improve transient response damping can result in slower recovery times, but will not
affect the peak output voltage deviation. Typical ASCR Gain settings range from 100 to 1000, and ASCR Residual settings range from
10 to 90.
Paged or Global: Paged
Data Length in Bytes: 4
Data Format: Bit Field and nonsigned binary
Type: R/W
Protectable: Yes
Default Value: 015A0100h (Gain = 256d, Residual = 90d, ASCR enabled)
Units: N/A
COMMAND
Format
ASCR_CONFIG (DFh)
Bit Field/Linear-8 Unsigned
Bit Position
Access
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
Format
0
0
0
0
0
0
0
1
1
0
1
0
0
0
0
0
Linear-16 Unsigned
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
BITS
PURPOSE
Not Used
VALUE
0000000h
1
DESCRIPTION
31:25
Not Used
Enable
24
ASCR Enable
0
Disable
23:16
15:0
ASCR Residual Setting
ASCR Gain Setting
5Ah
ASCR residual
ASCR gain
0100h
FN7558.3
September 14, 2015
Submit Document Feedback
67
ZL8800
SEQUENCE (E0h)
Definition: Identifies the Rail DDC ID of the prequel and sequel rails when performing multirail sequencing. The device will enable its
output when its EN or OPERATION enable state, as defined by ON_OFF_CONFIG, is set and the prequel device has issued a power-good
event on the DDC bus. The device will disable its output (using the programmed delay values) when the sequel device has issued a
power-down event on the DDC bus.
The data field is a two-byte value. The most-significant byte contains the 5-bit Rail DDC ID of the prequel device. The least-significant
byte contains the 5-bit Rail DDC ID of the sequel device. The most significant bit of each byte contains the enable of the prequel or
sequel mode. This command overrides the corresponding sequence configuration set by the CONFIG pin settings.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 00h (Prequel and sequel disabled)
Units: N/A
COMMAND
Format
SEQUENCE (E0h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BIT
FIELD NAME
VALUE
SETTING
Disable
Enable
DESCRIPTION
Disable, no prequel preceding this rail
0
15
Prequel Enable
1
Enable, prequel to this rail is defined by bits 12:8
Not Used
14:13
12:8
Not Used
0
0-31d
0
Not Used
DDC ID
Disable
Enable
Prequel Rail DDC ID
Set to the DDC ID of the prequel rail
Disable, no sequel following this rail
Enable, sequel to this rail is defined by bits 4:0
Not Used
7
Sequel Enable
1
6:5
4:0
Not Used
0
Not Used
DDC ID
Sequel Rail DDC ID
0-31d
Set to the DDC ID of the sequel rail
FN7558.3
September 14, 2015
Submit Document Feedback
68
ZL8800
TRACK_CONFIG (E1h)
Definition: Configures the voltage tracking modes of the device. Only 1 channel can be configured to track: Channel 0, Channel 1 or the
output of a 2-phase application.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 00h
Units: N/A
COMMAND
Format
TRACK_CONFIG (E1h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
BIT
7
FIELD NAME
VALUE
SETTING
Disable
Enable
Not Used
100%
DESCRIPTION
0
Tracking is disabled
Tracking is enabled
Not Used
Voltage Tracking Control
Not Used
1
6:3
2
0000
0
1
0
1
0
1
Output tracks at 100% ratio of VTRK input
Output tracks at 50% ratio of VTRK input
Output voltage is limited by target voltage
Output voltage is limited by VTRK voltage
Tracking Ratio Control
50%
Target Voltage
VTRK Voltage
Track after PG
Track always
1
0
Tracking Upper Limit
Ramp-Up Behavior
The output is not allowed to track VTRK down before power-good
The output is allowed to track VTRK down before power-good
FN7558.3
September 14, 2015
Submit Document Feedback
69
ZL8800
DDC_GROUP (E2h)
Definition: Rails (output voltages) are assigned Group numbers in order to share specified behaviors. The DDC_GROUP command
configures fault spreading group ID and enable, broadcast OPERATION group ID and enable, and broadcast VOUT_COMMAND group ID
and enable. Note that DDC Groups are separate and unique from DDC Phases and INTERLEAVE groups. Current sharing rails need to be
in the same DDC Group in order to respond to broadcast VOUT_COMMAND and OPERATION commands. Power fail event responses
(and Phases) are automatically spread in phase 0 and 1 when the ZL8800 is operating in 2-phase current sharing mode when it is
configured using DDC_CONFIG, regardless of it’s setting in DDC_GROUP.
Paged or Global: Paged
Data Length in Bytes: 3
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 000000h (Ignore BROADCAST VOUT_COMMAND and OPERATION, Sequence shutdown on POWER_FAIL event)
Units: N/A
COMMAND
Format
DDC_GROUP (E2h)
Bit Field
Bit Position 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Access
R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/ R/
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Function
See Following Table
Default
Value
Lower 5 bits of device
address
Lower 5 bits of device
address
Lower 5 bits of device
address
0
0
0
0
0
0
0
0
0
BITS
PURPOSE
Not Used
VALUE
DESCRIPTION
23:22
00
1
Not Used
Responds to BROADCAST_VOUT_COMMAND with same Group ID
Ignores BROADCAST_VOUT_COMMAND
21
BROADCAST_VOUT_COMMAND response
0
20:16 BROADCAST_VOUT_COMMAND group ID
0-31d Group ID sent as data for broadcast BROADCAST_VOUT_COMMAND events
15:14
13
Not Used
00
1
Not Used
Responds to BROADCAST_OPERATION with same Group ID
Ignores BROADCAST_OPERATION
BROADCAST_OPERATION response
0
12:8
7:6
BROADCAST_OPERATION group ID
Not Used
0-31d Group ID sent as data for broadcast BROADCAST_OPERATION events
00
1
Not Used
Responds to POWER_FAIL events with same Group ID by shutting down immediately
Responds to POWER_FAIL events with same Group ID with sequenced shutdown
5
POWER_FAIL response
POWER_FAIL group ID
0
4:0
0-31d Group ID sent as data for broadcast POWER_FAIL events
FN7558.3
September 14, 2015
Submit Document Feedback
70
ZL8800
DEVICE_ID (E4h)
Definition: Returns the 16-byte (character) device identifier string. The format is: Part number, Major Revision, (period), Minor Revision,
Engineering version letter
Paged or Global: Global
Data Length in Bytes: 16
Data Format: ASCII. ISO/IEC 8859-1
Type: Block Read
Protectable: No
Default Value: ZL8800, current major revision, (period), current minor revision, current engineering version letter
Units: N/A
COMMAND
Format
DEVICE_ID (E4h)
Characters (Bytes)
Characters
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Part Number
Maj. Rev.
.
Min. Rev
Engr.
*
Default Value
Z
L
8
8
0
0
*
*
*
*
*
* current revision at time of manufacture
MFR_IOUT_OC_FAULT_RESPONSE (E5h)
Definition: Configures the I overcurrent fault response as defined by the following table. The command format is the same as the
OUT
PMBus™ standard fault responses except that it sets the overcurrent status bit in STATUS_IOUT. The retry time is the time between
restart attempts.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate shutdown, no retries)
Units: Retry time = 70ms
COMMAND
Format
MFR_IOUT_OC_FAULT_RESPONSE (E5h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
DESCRIPTION
Response Behavior: For all modes, the
device:
• Pulls SALRT low
• Sets the related fault bit in the
status registers. Fault bits are only
cleared by the CLEAR_FAULTS
command.
00
01
10
Not Used
Not Used
Disable without delay and retry according to the setting in bits 5:3.
11
Not Used
000
No retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command or both), bias power is
removed, or another fault condition causes the unit to shut down.
111
000-111 Not Used
FN7558.3
September 14, 2015
Submit Document Feedback
71
ZL8800
MFR_IOUT_UC_FAULT_RESPONSE (E6h)
Definition: Configures the I undercurrent fault response as defined by the following table. The command format is the same as the
OUT
PMBus™ standard fault responses except that it sets the undercurrent status bit in STATUS_IOUT. The retry time is the time between
restart attempts.
Data Length in Bytes: 1
Paged or Global: Paged
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate shutdown, no retries)
Units: Retry time unit = 70ms
COMMAND
Format
MFR_IOUT_UC_FAULT_RESPONSE (E6h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
00
DESCRIPTION
Response Behavior: For all modes, the device:
• Pulls SALRT low
• Sets the related fault bit in the status
registers. Fault bits are only cleared by the
CLEAR_FAULTS command.
Not Used
Not Used
01
10
Disable without delay and retry according to the setting in bits 5:3.
Not Used
11
000
No retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it
is commanded OFF (by the CONTROL pin or OPERATION command or both), bias
power is removed, or another fault condition causes the unit to shut down.
111
000-111 Not Used
FN7558.3
September 14, 2015
Submit Document Feedback
72
ZL8800
IOUT_AVG_OC_FAULT_LIMIT (E7h)
Definition: Sets the I average overcurrent fault threshold. For downslope sensing, this corresponds to the average of all the current
OUT
samples taken during the (1-D) time interval, excluding the current sense blanking time (which occurs at the beginning of the 1-D
interval). For up-slope sensing, this corresponds to the average of all the current samples taken during the D time interval, excluding the
current sense blanking time (which occurs at the beginning of the D interval). This feature shares the OC fault bit operation (in
STATUS_IOUT) and OC fault response with IOUT_ OC_FAULT_LIMIT.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0.8 x IOUT_OC_FAULT_LIMIT
Units: Amperes
N
Equation: IOUT_AVG_OC_FAULT_LIMIT = Y×2
Range: -100 to 100A
COMMAND
Format
IOUT_AVG_OC_FAULT_LIMIT (E7h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
0.8 x IOUT_OC_FAULT_LIMIT
Default Value
IOUT_AVG_UC_FAULT_LIMIT (E8h)
Definition: Sets the IOUT average undercurrent fault threshold. For downslope sensing, this corresponds to the average of all the current
samples taken during the (1-D) time interval, excluding the current sense blanking time (which occurs at the beginning of the 1-D
interval). For up-slope sensing, this corresponds to the average of all the current samples taken during the D time interval, excluding the
current sense blanking time (which occurs at the beginning of the D interval). This feature shares the UC fault bit operation (in
STATUS_IOUT) and UC fault response with IOUT_ UC_FAULT_LIMIT.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: 0.8 x IOUT_UC_FAULT_LIMIT
Units: Amperes
N
Equation: IOUT_AVG_UC_FAULT_LIMIT = Y×2
Range: -100 to 100A
COMMAND
Format
IOUT_AVG_UC_FAULT_LIMIT (E8h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
0.8 x IOUT_UC_FAULT_LIMIT
Default Value
FN7558.3
September 14, 2015
Submit Document Feedback
73
ZL8800
USER_GLOBAL_CONFIG (E9h)
Definition: This command is used to set options for output voltage sensing, maximum output voltage override, SMBus time-out, and
DDC and SYNC output configurations.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Bit Field
Type: R/W
Protectable: Yes
Default Value: 0000h
Units: N/A
COMMAND
Format
USER_GLOBAL_CONFIG (E9h)
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BITS
PURPOSE
Not Used
VALUE
DESCRIPTION
15:10
000000
Not Used
Vsense Select for monitoring and fault
detection
00
01
10
0
Output 0 uses VSEN0, Output 1 uses VSEN1
Both outputs use VSEN0
Both outputs use VSEN1
Not Used
9:8
7
6
5
4
3
Not Used
DDC output Configuration
0
DDC output open drain
DDC output push-pull
Not Used
1
Not Used
0
Disable SMBus Time-Outs
0
SMBus time-outs enabled
SMBus time-outs disabled
Not Used
1
Not Used
0
Sync I/O Control
00
01
10
11
0
Use internal clock (frequency initially set with pin-strap)
Use internal clock and output internal clock (not for use with pin-strap)
2:1
0
Use external clock
Not Used
Not Used
Not Used
FN7558.3
September 14, 2015
Submit Document Feedback
74
ZL8800
SNAPSHOT (EAh)
Definition: The SNAPSHOT command is a 32-byte read-back of parametric and status values. It allows monitoring and status data to be
stored to flash either during a fault condition or via a system-defined time using the SNAPSHOT_CONTROL command. Snapshot is
continuously updated in RAM and can be read using the SNAPSHOT command. When a fault occurs, the latest snapshot in RAM is
stored to flash. Snapshot data can read back by writing a 01h to the SNAPSHOT_CONTROL command, then reading SNAPSHOT.
Paged or Global: Paged
Data Length in Bytes: 32
Data Format: Bit Field
Type: Block Read
Protectable: No
Default Value: N/A
Units: N/A
BYTE NUMBER
VALUE
Not Used
PMBus™ COMMAND
Not Used
FORMAT
0000h
31:23
22
Flash Memory Status Byte
Manufacturer Specific Status Byte
CML Status Byte
N/A
Bit Field
21
STATUS_MFR_SPECIFIC (80h)
STATUS_CML (7Eh)
STATUS_TEMPERATURE (7Dh)
STATUS_INPUT (7Ch)
STATUS_IOUT (7Bh)
STATUS_VOUT (7Ah)
READ_FREQUENCY (95h)
READ_TEMPERATURE_2 (8Eh)
READ_TEMPERATURE_1 (8Dh)
READ_DUTY_CYCLE (94h)
N/A
1 Byte Bit Field
1 Byte Bit Field
1 Byte Bit Field
1 Byte Bit Field
1 Byte Bit Field
1 Byte Bit Field
2 Byte Linear-11
2 Byte Linear-11
2 Byte Linear-11
2 Byte Linear-11
2 Byte Linear-11
2 Byte Linear-11
2 Byte Linear-16 Unsigned
2 Byte Linear-11
20
19
Temperature Status Byte
Input Status Byte
18
17
Iout Status Byte
16
Vout Status Byte
15:14
13:12
11:10
9:8
Switching Frequency
External Temperature
Internal Temperature
Duty Cycle
7:6
Highest Measured Output Current
Output Current
5:4
READ_IOUT (8Ch)
3:2
Output Voltage
READ_VOUT (8Bh)
1:0
Input Voltage
READ_VIN (88h)
BLANK_PARAMS (EBh)
Definition: Returns a 16-byte string which indicates which parameter values were either retrieved by the last RESTORE operation or
have been written since that time. Reading BLANK_PARAMS immediately after a restore operation allows the user to determine which
parameters are stored in that store. A one indicates the parameter is not present in the store and has not been written since the
RESTORE operation.
Paged or Global: Paged
Data Length in Bytes: 16
Data Format: Bit Field
Type: Block Read
Protectable: No
Default Value: FF…FFh
Units: N/A
FN7558.3
September 14, 2015
Submit Document Feedback
75
ZL8800
LEGACY_FAULT_GROUP (F0h)
Definition: This command allows the ZL8800 to sequence and fault spread with devices other than the ZL8800 family of ICs. This
command sets which rail DDC IDs should be listened to for fault spreading information. The data sent is a 4-byte, 32-bit bit vector
where every bit represents a rail’s DDC ID. A bit set to 1 indicates a device DDC ID to which the configured device will respond upon
receiving a fault spreading event. In this vector, bit 0 of byte 0 corresponds to the rail with DDC ID 0. Following through, Bit 7 of byte 3
corresponds to the rail with DDC ID 31.
NOTE: The device/rail’s own DDC ID should not be set within the LEGACY_FAULT_GROUP command for that device/rail.
All devices in a current share rail (devices other than the ZL8800 family ICs) must shut down for the rail to report a shutdown.
If fault spread mode is enabled in USER_CONFIG, the device will immediately shut down if on of its DDC_GROUP members fail. The
device/rail will attempt its configured restart only after all devices/rails within the DDC_GROUP have cleared their faults.
If fault spread mode is disabled in USER_CONFIG, the device will perform a sequenced shutdown as defined by the SEQUENCE
command setting. The rails/devices in a sequencing set only attempt their configured restart after all faults have cleared within the
DDC_GROUP. If fault spread mode is disabled and sequencing is also disabled, the device will ignore faults from other devices and stay
enabled.
Paged or Global: Paged
Data Length in Bytes: 4
Data Format: Bit field
Type: Block R/W
Protectable: Yes
Default Value: 00000000h
Units: N/A
COMMAND
Format
LEGACY_FAULT_GROUP (F0h)
Bit Field
Bit Position
Access
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
Format
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit Field
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BIT
FIELD NAME
Fault Group
VALUE
NA
SETTING
DESCRIPTION
31:0
00000000h Identifies the devices in the fault spreading group.
FN7558.3
September 14, 2015
Submit Document Feedback
76
ZL8800
SNAPSHOT_CONTROL (F3h)
Definition: Writing a 01h will cause the device to copy the current SNAPSHOT values from NVRAM to the 32-byte SNAPSHOT command
parameter. Writing a 02h will cause the device to write the current SNAPSHOT values to NVRAM, 03h will erase all SNAPSHOT values
from NVRAM. Write (02h) and Erase (03h) may only be used when the device is disabled. All other values will be ignored.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W byte
Protectable: Yes
Default Value: N/A
Units: N/A
COMMAND
Format
SNAPSHOT_CONTROL (F3h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
0
0
0
0
VALUE
01
DESCRIPTION
Read SNAPSHOT values from NVRAM
Write SNAPSHOT values to NVRAM
Erase SNAPSHOT values from NV RAM
02
03
RESTORE_FACTORY (F4h)
Definition: Restores the device to the hard-coded Factory default values and pin-strap definitions. The device retains the DEFAULT and
USER stores for restoring. Security level is changed to Level 1 following this command.
Paged or Global: Global
Data Length in Bytes: 0
Data Format: N/A
Type: Write only
Protectable: Yes
Default Value: N/A
Units: N/A
MFR_VMON_OV_FAULT_LIMIT (F5h)
Definition: Sets the VMON overvoltage fault threshold. A VMON parameter equals 16 times the voltage applied to the VMON pin. The
VMON overvoltage warn limit is automatically set to 90% of this fault value.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: D300h (12V)
Units: V
N
Equation: MFR_VMON_OV_FAULT_LIMIT = Y×2
Range: 0 to 19V
COMMAND
Format
MFR_VMON_OV_FAULT_LIMIT (F5h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
1
0
1
0
0
1
1
0
0
0
0
0
0
0
0
FN7558.3
September 14, 2015
Submit Document Feedback
77
ZL8800
MFR_VMON_UV_FAULT_LIMIT (F6h)
Definition: Sets the VMON undervoltage fault threshold. A VMON parameter equals 16x the voltage applied to the VMON pin. The VMON
undervoltage warn limit is automatically set to 110% of this fault value.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: R/W
Protectable: Yes
Default Value: CA40h (4.5V)
Units: V
N
Equation: MFR_VMON_UV_FAULT_LIMIT = Y x 2
Range: 0 to 19V
COMMAND
Format
MFR_VMON_UV_FAULT_LIMIT (F6h)
Linear-11
Bit Position
Access
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
Signed Mantissa, Y
Default Value
1
1
0
0
1
0
1
0
0
1
0
0
0
0
0
0
MFR_READ_VMON (F7h)
Definition: Reads the VMON voltage.
Paged or Global: Global
Data Length in Bytes: 2
Data Format: Linear-11.
Type: Read only
Protectable: No
Default Value: N/A
Units: V
N
Equation: MFR_READ_VMON = Y x 2
Range: 0 to 19V
COMMAND
Format
MFR_READ_VMON (F7h)
Linear-11
Bit Position
Access
15
14
13
R/W
12
11
10
9
8
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Signed Exponent, N
N/A N/A N/A
Signed Mantissa, Y
N/A N/A N/A
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
FN7558.3
September 14, 2015
Submit Document Feedback
78
ZL8800
VMON_OV_FAULT_RESPONSE (F8h)
Definition: Configures the VMON overvoltage fault response as defined by the following table. The retry time is the time between restart
attempts
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate Shutdown, no retries)
Units: Retry time unit = 70ms
COMMAND
Format
VMON_OV_FAULT_RESPONSE (F8h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
DESCRIPTION
00
01
10
Not Used
Not Used
Disable without delay and retry according to the setting in bits 5:3.
Response Behavior: The device:
• Pulls SALRT low
• Sets the related fault bit in the
status registers. Fault bits are only
cleared by the CLEAR_FAULTS
command.
Output is disabled while the fault is present. Operation resumes and the output is enabled
when the fault condition no longer exists.
11
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command or both), bias power is
removed, or another fault condition causes the unit to shut down.
111
000-111 Not Used
FN7558.3
September 14, 2015
Submit Document Feedback
79
ZL8800
VMON_UV_FAULT_RESPONSE (F9h)
Definition: Configures the VMON undervoltage fault response as defined by the following table. Note: The retry time is the time between
restart attempts
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field.
Type: R/W
Protectable: Yes
Default Value: 80h (Immediate shutdown, no retries)
Units: Retry time unit = 70ms
COMMAND
Format
VMON_UV_FAULT_RESPONSE (F9h)
Bit Field
Bit Position
Access
7
6
5
4
3
2
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
1
0
0
0
0
0
0
0
BIT
7:6
FIELD NAME
VALUE
DESCRIPTION
Response Behavior: The device:
• Pulls SALRT low
• Sets the related fault bit in the
status registers. Fault bits are only
cleared by the CLEAR_FAULTS
command.
00
01
10
Not Used
Not Used
Disable without delay and retry according to the setting in bits 5:3.
Output is disabled while the fault is present. Operation resumes and the output is enabled
when the fault condition no longer exists.
11
000
No Retry. The output remains disabled until the fault is cleared.
001-110 Not Used
5:3
2:0
Retry Setting
Not Used
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command or both), bias power is
removed, or another fault condition causes the unit to shut down.
111
000-111 Not Used
SECURITY_LEVEL (FAh)
Definition: The device provides write protection for individual commands. Each bit in the UNPROTECT parameter controls whether its
corresponding command is writeable (commands are always readable). If a command is not writeable, a password must be entered in
order to change its parameter (i.e., to enable writes to that command). There are two types of passwords, public and private. The public
password provides a simple lock-and-key protection against accidental changes to the device. It would typically be sent to the device in
the application prior to making changes. Private passwords allow commands marked as non-writeable in the UNPROTECT parameter to
be changed. Private passwords are intended for protecting default-installed configurations and would not typically be used in the
application. Each store (USER and DEFAULT) can have its own UNPROTECT string and private password. If a command is marked as
non-writeable in the DEFAULT UNPROTECT parameter (its corresponding bit is cleared), the private password in the DEFAULT Store must
be sent in order to change that command. If a command is writeable according to the Default UNPROTECT parameter, it may still be
marked as non-writeable in the User Store UNPROTECT parameter. In this case, the User private password can be sent to make the
command writeable.
The device supports four levels of security. Each level is designed to be used by a particular class of users, ranging from module
manufacturers to end users, as discussed in the following. Levels 0 and 1 correspond to the public password. All other levels require a
private password. Writing a private password can only raise the security level. Writing a public password will reset the level down to 0 or
1.
Figure 12 shows the algorithm used by the device to determine if a particular command write is allowed.
FN7558.3
September 14, 2015
Submit Document Feedback
80
ZL8800
Write
Attempted
Always
Writeable
?
Y
N
Read
Only
?
Y
N
Security
Level == 3
?
Y
N
Default
UNPROTECT
== 0
Y
?
N
Security
Level == 2
?
Y
N
User
UNPROTECT
== 0
?
Y
N
Security
Level == 1
?
Write
Prohibited
Write
Allowed
N
Y
FIGURE 12. ALGORITHM USED TO DETERMINE WHEN A COMMAND IS WRITEABLE
Security Level 3 – Module Vendor
Level 3 is intended primarily for use by Module vendors to protect device configurations in the Default Store. Clearing a UNPROTECT bit
in the Default Store implies that a command is writeable only at Level 3 and above. The device’s security level is raised to Level 3 by
writing the private password value previously stored in the Default Store. To be effective, the module vendor must clear the UNPROTECT
bit corresponding to the STORE_DEFAULT_ALL and RESTORE_DEFAULT commands. Otherwise, Level 3 protection is ineffective since
the entire store could be replaced by the user, including the enclosed private password.
Security Level 2 – User
Level 2 is intended for use by the end user of the device. Clearing a UNPROTECT bit in the User Store implies that a command is
writeable only at Level 2 and above. The device’s security level is raised to Level 2 by writing the private password value previously
stored in the User Store. To be effective, the user must clear the UNPROTECT bit corresponding to the STORE_USER_ALL,
RESTORE_DEFAULT_ALL, STORE_DEFAULT_ALL, and RESTORE_DEFAULT commands. Otherwise, Level 2 protection is ineffective since
the entire store could be replaced, including the enclosed private password.
Security Level 1 – Public
Level 1 is intended to protect against accidental changes to ordinary commands by providing a global write-enable. It can be used to
protect the device from erroneous bus operations. It provides access to commands whose UNPROTECT bit is set in both the Default and
User Store. Security is raised to Level 1 by writing the public password stored in the User Store using the PUBLIC_PASSWORD
command. The public password stored in the Default Store has no effect.
FN7558.3
September 14, 2015
Submit Document Feedback
81
ZL8800
Security Level 0 - Unprotected
Level 0 implies that only commands which are always writeable (e.g., PUBLIC_PASSWORD) are available. This represents the lowest
authority level and hence the most protected state of the device. The level can be reduced to 0 by using PUBLIC_PASSWORD to write
any value which does not match the stored public password.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Hex
Type: Read Byte
Protectable: No
Default Value: 01h
Units: N/A
Reference: AN2031 - Writing Configuration Files for Intersil Digital Power
PRIVATE_PASSWORD (FBh)
Definition: Sets the private password string.
Paged or Global: Global
Data Length in Bytes: 9
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: No
Default Value: 000000000000000000h
Units: N/A
Reference: AN2031 - Writing Configuration Files for Intersil Digital Power
PUBLIC_PASSWORD (FCh)
Definition: Sets the public password string.
Paged or Global: Global
Data Length in Bytes: 4
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Protectable: No
Default Value: 00000000h
Units: N/A
Reference: AN2031 - Writing Configuration Files for Intersil Digital Power
UNPROTECT (FDh)
Definition: Sets a 256-bit (32-byte) parameter which identifies which commands are to be protected against write-access at lower
security levels. Each bit in this parameter corresponds to a command according to the command’s code. The command with a code of
00h (PAGE) is protected by the least-significant bit of the least-significant byte, followed by the command with a code of 01h and so
forth. Note that all possible commands have a corresponding bit regardless of whether they are protectable or supported by the device.
Clearing a command’s UNPROTECT bit indicates that write-access to that command is only allowed if the device’s security level has
been raised to an appropriate level. The UNPROTECT bits in the DEFAULT store require a security level 3 or greater to be writeable. The
UNPROTECT bits in the USER store require a security level of 2 or higher.
Data Length in Bytes: 32
Paged or Global: Global
Data Format: Custom
Type: Block R/W
Protectable: No
Default Value: FF…FFh
Units: N/A
Reference: AN2031 - Writing Configuration Files for Intersil Digital Power
FN7558.3
September 14, 2015
Submit Document Feedback
82
ZL8800
Firmware Revision History
FIRMWARE REVISION CODE
CHANGE DESCRIPTION
NOTE
1.04
Initial Release
Not recommended for a new design
1. Fix to start-up routine to improve SA pin read
performance at cold temperatures.
2. Improved fault retry performance.
3. Improved DDC compatibility with previous generations
of Intersil controllers and modules.
1.06
Recommended for a new design
4. Addition of the LEGACY_FAULT_GROUP command to
allow for fault spreading over Intersil’s DDC bus with
previous generation of controllers and modules.
Revision History
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to web to make sure you
have the latest revision.
DATE
REVISION
FN7558.3
CHANGE
September 14, 2015
-Added Related Literature section on page 1.
-Added Key Differences table to page 1.
-Updated Ordering Information table on page 8 by adding ZL8800ALBFT and ZL8800ALBFTK part numbers,
added FIRMWARE REVISION column, and added Note 5.
-Added LEGACY_FAULT_GROUP command to “PMBus™ Command Summary” on page 27 and in the
Command descriptions on page 76.
-Changed reference to 30ms to 70ms, and 20 to 30ms to 60 to 70ms in “Start-Up Procedure” on page 15.
-Added detail to TON_DELAY Range description on page 47.
-Added detail to TON_RISE Range description on page 47.
-Added detail to TOFF_DELAY Range description on page 48.
-Added Firmware Revision History section.
November 11, 2013
October 10, 2013
FN7558.2
FN7558.1
Added “™” to ChargeMode - page 1 title, 3rd paragraph and trademark statement bottom of page.
The maximum, ramp-up time and ramp-down time changed from 200ms to 100ms: pages 10, 47, 48.
The maxiumum soft-start delay, turn-off delay and power-good delay changed on pages 47, 48 and 62 to 5
seconds to match the limits in the EC table (page 10).
The 2nd table on page 60. The location and size of the bit field for minimum duty cycle changed from 2 bits
in location 9:8 to 5 bits in location 15:11.
September 18, 2013
FN7558.0
Initial Release
About Intersil
Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products
address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets.
For the most updated datasheet, application notes, related documentation and related parts, please see the respective product
information page found at www.intersil.com.
You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask.
Reliability reports are also available from our website at www.intersil.com/support.
For additional products, see www.intersil.com/en/products.html
Intersil products are manufactured, assembled and tested utilizing ISO9001 quality systems as noted
in the quality certifications found at www.intersil.com/en/support/qualandreliability.html
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time
without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be
accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third
parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
FN7558.3
September 14, 2015
Submit Document Feedback
83
ZL8800
Package Outline Drawing
L44.7x7B
44 LEAD QUAD FLAT NO-LEAD PLASTIC PACKAGE
Rev 0, 10/09
5.00 TYP
40X 0.50
7.00
A
6
B
44
PIN #1
INDEX
AREA
34
1
6
33
PIN 1
INDEX
AREA
5.20 ±0.1
EXP. DAP
23
11
44X 0.25 4
0.10 M C A B
(4X)
0.15
22
12
SIDE VIEW
TOP VIEW
5.20 ±0.1 EXP. DAP
BOTTOM VIEW
44X 0.55 ±0.1
( 6.65 )
SEE DETAIL "X"
( 5.20)
0.10C
C
1.00 MAX
0.08C
SIDE VIEW
( 6.65 )
( 5.20 )
( 40X 0.50)
5
C
0.2 REF
(44X .25)
0 . 00 MIN.
0 . 05 MAX.
( 44 X 0.75)
TYPICAL RECOMMENDED LAND PATTERN
DETAIL "X"
NOTES:
1. Dimensions are in millimeters.
Dimensions in ( ) for Reference Only.
2. Dimensioning and tolerancing conform to AMSE Y14.5m-1994.
3.
Unless otherwise specified, tolerance : Decimal ± 0.05
4. Dimension b applies to the metallized terminal and is measured
between 0.15mm and 0.30mm from the terminal tip.
Tiebar shown (if present) is a non-functional feature.
5.
6.
The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 identifier may be
either a mold or mark feature.
Complies to JEDEC MO220 VKKD-1.
7.
FN7558.3
September 14, 2015
Submit Document Feedback
84
相关型号:
ZL8800-2PH-DEMO1Z
Dual Channel/Dual Phase PMBus⢠ChargeMode⢠Control DC/DC Digital Controller
INTERSIL
ZL8800ALBFT
Dual Channel/Dual Phase PMBus⢠ChargeMode⢠Control DC/DC Digital Controller
INTERSIL
ZL8800ALBFTK
Dual Channel/Dual Phase PMBus⢠ChargeMode⢠Control DC/DC Digital Controller
INTERSIL
©2020 ICPDF网 联系我们和版权申明