IS42S16400E [ISSI]
1 Meg Bits x 16 Bits x 4 Banks (64-MBIT) SYNCHRONOUS DYNAMIC RAM; 1梅格位×16位× 4银行( 64兆位)同步动态RAM型号: | IS42S16400E |
厂家: | INTEGRATED SILICON SOLUTION, INC |
描述: | 1 Meg Bits x 16 Bits x 4 Banks (64-MBIT) SYNCHRONOUS DYNAMIC RAM |
文件: | 总55页 (文件大小:790K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
performance.TheꢀsynchronousꢀDRAMsꢀachieveꢀhigh-speedꢀ
data transfer using pipeline architecture. All inputs and
outputs signals refer to the rising edge of the clock input.
IS42S16400E
1 Meg Bits x 16 Bits x 4 Banks (64-MBIT)
SYNCHRONOUS DYNAMIC RAM
AUGUST 2009
FEATURES
OVERVIEW
ISSI'sꢀ 64Mbꢀ Synchronousꢀ DRAMꢀ IS42S16400Eꢀ isꢀ
•ꢀ Clockꢀfrequency:ꢀ166,ꢀ143ꢀMHz
organizedꢀasꢀ1,048,576ꢀbitsꢀxꢀ16-bitꢀxꢀ4-bankꢀforꢀimprovedꢀ
•ꢀ Fullyꢀsynchronous;ꢀallꢀsignalsꢀreferencedꢀtoꢀaꢀ
positive clock edge
•ꢀ Internalꢀbankꢀforꢀhidingꢀrowꢀaccess/precharge
•ꢀ Singleꢀ3.3Vꢀpowerꢀsupply
•ꢀ LVTTLꢀinterface
PIN CONFIGURATIONS
54-Pin TSOP (Type II)
•ꢀ Programmableꢀburstꢀlengthꢀ
–ꢀ(1,ꢀ2,ꢀ4,ꢀ8,ꢀfullꢀpage)
VDD
DQ0
VDDQ
DQ1
DQ2
GNDQ
DQ3
DQ4
VDDQ
DQ5
DQ6
GNDQ
DQ7
VDD
LDQM
WE
1
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
GND
DQ15
GNDQ
DQ14
DQ13
VDDQ
DQ12
DQ11
GNDQ
DQ10
DQ9
VDDQ
DQ8
GND
NC
•ꢀ Programmableꢀburstꢀsequence:ꢀ
Sequential/Interleave
2
3
4
5
•ꢀ Selfꢀrefreshꢀmodes
6
7
•ꢀ 4096ꢀrefreshꢀcyclesꢀeveryꢀ64ꢀms
•ꢀ Randomꢀcolumnꢀaddressꢀeveryꢀclockꢀcycle
•ꢀ ProgrammableꢀCASꢀlatencyꢀ(2,ꢀ3ꢀclocks)
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
•ꢀ Burstꢀread/writeꢀandꢀburstꢀread/singleꢀwriteꢀ
UDQM
CLK
CKE
NC
operations capability
CAS
RAS
CS
•ꢀ Burstꢀterminationꢀbyꢀburstꢀstopꢀandꢀprechargeꢀ
BA0
BA1
A10
A11
command
A9
A8
•ꢀ ByteꢀcontrolledꢀbyꢀLDQMꢀandꢀUDQM
•ꢀ Package:ꢀꢀ400-milꢀ54-pinꢀTSOPꢀII
•ꢀ Lead-freeꢀpackageꢀisꢀavailable
•ꢀ AvailableꢀinꢀIndustrialꢀtemperature
A0
A7
A1
A6
A2
A5
A3
A4
VDD
GND
PIN DESCRIPTIONS
WEꢀ
ꢀ
ꢀ
WriteꢀEnable
A0-A11ꢀ ꢀ
AddressꢀInput
LDQMꢀ
LowerꢀBye,ꢀInput/OutputꢀMask
UpperꢀBye,ꢀInput/OutputꢀMask
Power
BA0,ꢀBA1ꢀ
BankꢀSelectꢀAddress
DataꢀI/O
UDQMꢀ ꢀ
DQ0ꢀtoꢀDQ15ꢀ
VDDꢀ
ꢀ
ꢀ
ꢀ
ꢀ
CLKꢀ
CKEꢀ
CS
ꢀ
ꢀ
SystemꢀClockꢀInput
ClockꢀEnable
GNDꢀ
VDDqꢀ
GNDqꢀ
NC
Ground
PowerꢀSupplyꢀforꢀDQꢀPin
GroundꢀforꢀDQꢀPin
No Connection
Chip Select
RASꢀ
CAS
ꢀ
RowꢀAddressꢀStrobeꢀCommand
Column Address Strobe Command
Copyright © 2006 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no
liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on
any published information and before placing orders for products.
Integrated Silicon Solution, Inc. — www.issi.com
1
Rev. C
08/07/09
IS42S16400E
GENERAL DESCRIPTION
Theꢀ 64Mbꢀ SDRAMꢀ isꢀ aꢀ highꢀ speedꢀ CMOS,ꢀ dynamicꢀ
random-accessꢀ memoryꢀ designedꢀ toꢀ operateꢀ inꢀ 3.3Vꢀ
memoryꢀsystemsꢀcontainingꢀ67,108,864ꢀbits.ꢀꢀInternallyꢀ
configuredꢀasꢀaꢀquad-bankꢀDRAMꢀwithꢀaꢀsynchronousꢀ
interface.ꢀꢀEachꢀ16,777,216-bitꢀbankꢀisꢀorganizedꢀasꢀ4,096ꢀ
rowsꢀbyꢀ256ꢀcolumnsꢀbyꢀ16ꢀbits.
otherthreebankswillhidetheprechargecyclesandprovide
seamless,ꢀhigh-speed,ꢀrandom-accessꢀoperation.
SDRAM readandwriteaccessesareburstorientedstarting
at a selected location and continuing for a programmed
numberꢀ ofꢀ locationsꢀ inꢀ aꢀ programmedꢀ sequence.ꢀ ꢀTheꢀ
registrationꢀ ofꢀ anꢀ ACTIVEꢀ commandꢀ beginsꢀ accesses,ꢀ
followedꢀbyꢀaꢀREADꢀorꢀWRITEꢀcommand.ꢀTheꢀACTIVEꢀ
command in conjunction with address bits registered are
usedꢀtoꢀselectꢀtheꢀbankꢀandꢀrowꢀtoꢀbeꢀaccessedꢀ(BA0,ꢀ
BA1ꢀselectꢀtheꢀbank;ꢀA0-A11ꢀselectꢀtheꢀrow).ꢀꢀTheꢀREADꢀ
orꢀWRITEꢀ commandsꢀ inꢀ conjunctionꢀ withꢀ addressꢀ bitsꢀ
registered are used to select the starting column location
for the burst access.
Theꢀ64MbꢀSDRAMꢀincludesꢀanꢀAUTOꢀREFRESHꢀMODE,ꢀ
andꢀaꢀpower-saving,ꢀpower-downꢀmode.ꢀAllꢀsignalsꢀareꢀ
registeredꢀonꢀtheꢀpositiveꢀedgeꢀofꢀtheꢀclockꢀsignal,ꢀCLK.ꢀ
AllꢀinputsꢀandꢀoutputsꢀareꢀLVTTLꢀcompatible.
Theꢀ64MbꢀSDRAMꢀhasꢀtheꢀabilityꢀtoꢀsynchronouslyꢀburstꢀ
dataꢀatꢀaꢀhighꢀdataꢀrateꢀwithꢀautomaticꢀcolumn-addressꢀ
generation, theabilitytointerleavebetweeninternalbanks
to hide precharge time and the capability to randomly
change column addresses on each clock cycle during
burst access.
ProgrammableꢀREADꢀorꢀWRITEꢀburstꢀlengthsꢀconsistꢀofꢀ
1,ꢀ2,ꢀ4ꢀandꢀ8ꢀlocations,ꢀorꢀfullꢀpage,ꢀwithꢀaꢀburstꢀterminateꢀ
option.
Aꢀself-timedꢀrowꢀprechargeꢀinitiatedꢀatꢀtheꢀendꢀofꢀtheꢀburstꢀ
sequenceꢀisꢀavailableꢀwithꢀtheꢀAUTOꢀPRECHARGEꢀfunctionꢀ
enabled. Precharge one bank while accessing one of the
FUNCTIONAL BLOCK DIAGRAM
CLK
CKE
CS
RAS
CAS
WE
DQM
DATA IN
BUFFER
COMMAND
DECODER
&
CLOCK
GENERATOR
16
16
REFRESH
CONTROLLER
MODE
REGISTER
DQ 0-15
A10
12
V
DD/VDDQ
SELF
DATA OUT
BUFFER
REFRESH
GND/GNDQ
A11
CONTROLLER
16
16
A9
A8
A7
A6
REFRESH
COUNTER
A5
A4
4096
A3
A2
A1
A0
BA0
BA1
4096
MEMORY CELL
ARRAY
4096
4096
12
BANK 0
ROW
ADDRESS
LATCH
ROW
ADDRESS
BUFFER
12
12
SENSE AMP I/O GATE
256K
(x 16)
COLUMN
ADDRESS LATCH
BANK CONTROL LOGIC
8
BURST COUNTER
COLUMN DECODER
COLUMN
ADDRESS BUFFER
8
2
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
PIN FUNCTIONS
Symbol
TSOP Pin No.
23ꢀtoꢀ26ꢀ
29ꢀtoꢀ34
22,ꢀ35
Type
Function (In Detail)
ꢀ
ꢀ
A0-A11ꢀ
InputꢀPin
ꢀ
AddressꢀInputs:ꢀA0-A11ꢀareꢀsampledꢀduringꢀtheꢀACTIVE
commandꢀ(row-addressꢀA0-A11)ꢀandꢀREAD/WRITEꢀcommandꢀ(A0-A7
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
withꢀA10ꢀdefiningꢀautoꢀprecharge)ꢀtoꢀselectꢀoneꢀlocationꢀoutꢀofꢀtheꢀmemoryꢀarray
inꢀtheꢀrespectiveꢀbank.ꢀA10ꢀisꢀsampledꢀduringꢀaꢀPRECHARGEꢀcommandꢀtoꢀdeter-
mineꢀifꢀallꢀbanksꢀareꢀtoꢀbeꢀprechargedꢀ(A10ꢀHIGH)ꢀorꢀbankꢀselectedꢀby
BA0,ꢀBA1ꢀ(LOW).ꢀTheꢀaddressꢀinputsꢀalsoꢀprovideꢀtheꢀop-codeꢀduringꢀaꢀLOADꢀ
MODEꢀREGISTERꢀcommand.
BA0,ꢀBA1
CAS
20,ꢀ21ꢀ
17ꢀ
InputꢀPin
InputꢀPin
InputꢀPin
ꢀ
BankꢀSelectꢀAddress:ꢀBA0ꢀandꢀBA1ꢀdefinesꢀwhichꢀbankꢀtheꢀACTIVE,ꢀREAD,ꢀWRITEꢀ
orꢀPRECHARGEꢀcommandꢀisꢀbeingꢀapplied.
CAS, in conjunction with the RAS and WE, forms the device command. See the
"CommandꢀTruthꢀTable"ꢀforꢀdetailsꢀonꢀdeviceꢀcommands.ꢀ
ꢀ
ꢀ
CKEꢀ
37ꢀ
ꢀ
TheꢀCKEꢀinputꢀdeterminesꢀwhetherꢀtheꢀCLKꢀinputꢀisꢀenabled.ꢀTheꢀnextꢀrisingꢀedgeꢀ
ofꢀtheꢀCLKꢀsignalꢀwillꢀbeꢀvalidꢀwhenꢀisꢀCKEꢀHIGHꢀandꢀinvalidꢀwhenꢀLOW.ꢀWhenꢀCKEꢀ
isꢀLOW,ꢀtheꢀdeviceꢀwillꢀbeꢀinꢀeitherꢀpower-downꢀmode,ꢀclockꢀsuspendꢀmode,ꢀorꢀselfꢀ
refresh mode. CKEꢀisꢀan asynchronous input.
CLKꢀ
38ꢀ
19ꢀ
InputꢀPin
ꢀ
ꢀ
CLKꢀisꢀtheꢀmasterꢀclockꢀinputꢀforꢀthisꢀdevice.ꢀExceptꢀforꢀCKE,ꢀallꢀinputsꢀtoꢀthisꢀdeviceꢀ
areꢀacquiredꢀinꢀsynchronizationꢀwithꢀtheꢀrisingꢀedgeꢀofꢀthisꢀpin.
CS
InputꢀPin
TheꢀCS input determines whether command input is enabled within the device.
Command input is enabled when CSꢀisꢀLOW,ꢀandꢀdisabledꢀwithꢀCSꢀisꢀHIGH.ꢀTheꢀ
device remains in the previous state when CSꢀisꢀHIGH.
ꢀ
ꢀ
DQ0ꢀtoꢀ
DQ15ꢀ
2,ꢀ4,ꢀ5,ꢀ7,ꢀ8,ꢀ10,ꢀ
11,13,ꢀ42,ꢀ44,ꢀ45,
47,ꢀ48,ꢀ50,ꢀ51,ꢀ53
15,ꢀ39ꢀ
DQꢀPin
ꢀ
ꢀ
DQ0ꢀtoꢀDQ15ꢀareꢀI/Oꢀpins.ꢀI/Oꢀthroughꢀtheseꢀpinsꢀcanꢀbeꢀcontrolledꢀinꢀbyteꢀunits
usingꢀtheꢀLDQMꢀandꢀUDQMꢀpins.
ꢀ
ꢀ
ꢀ
LDQM,ꢀ
UDQMꢀ
InputꢀPin
ꢀ
LDQMꢀandꢀUDQMꢀcontrolꢀtheꢀlowerꢀandꢀupperꢀbytesꢀofꢀtheꢀI/Oꢀbuffers.ꢀInꢀread
ꢀ
ꢀ
mode,ꢀLDQMꢀandꢀUDQMꢀcontrolꢀtheꢀoutputꢀbuffer.ꢀWhenꢀLDQMꢀorꢀUDQMꢀisꢀLOW,ꢀ
theꢀcorrespondingꢀbufferꢀbyteꢀisꢀenabled,ꢀandꢀwhenꢀHIGH,ꢀdisabled.ꢀTheꢀoutputsꢀ
goꢀtoꢀtheꢀHIGHꢀimpedanceꢀstateꢀwhenꢀLDQM/UDQMꢀisꢀHIGH.ꢀThisꢀfunctionꢀcor-
responds to OEꢀinꢀconventionalꢀDRAMs.ꢀInꢀwriteꢀmode,ꢀLDQMꢀandꢀUDQMꢀcontrolꢀ
theꢀinputꢀbuffer.ꢀWhenꢀLDQMꢀorꢀUDQMꢀisꢀLOW,ꢀtheꢀcorrespondingꢀbufferꢀbyteꢀisꢀen-
abled,ꢀandꢀdataꢀcanꢀbeꢀwrittenꢀtoꢀtheꢀdevice.ꢀWhenꢀLDQMꢀorꢀUDQMꢀisꢀHIGH,ꢀinputꢀ
data is masked and cannot be written to the device.
RAS
WE
18ꢀ
16ꢀ
InputꢀPin
RAS, in conjunction with CAS and WE, forms the device command. See the "Com-
mandꢀTruthꢀTable"ꢀitemꢀforꢀdetailsꢀonꢀdeviceꢀcommands.
ꢀInputꢀPin
WE, in conjunction with RAS and CAS, forms the device command. See the "Com-
mandꢀTruthꢀTable"ꢀitemꢀforꢀdetailsꢀonꢀdeviceꢀcommands.ꢀ
ꢀ
ꢀ
VD D q
VD D
3,ꢀ9,ꢀ43,ꢀ49ꢀ
1,ꢀ14,ꢀ27ꢀ
PowerꢀSupplyꢀPin
PowerꢀSupplyꢀPin
ꢀ
ꢀ
VD D q is the output buffer power supply.
VD D is the device internal power supply.
GNDq
GND
6,ꢀ12,ꢀ46,ꢀ52ꢀ
28,ꢀ41,ꢀ54ꢀ
PowerꢀSupplyꢀPin GNDq is the output buffer ground.
PowerꢀSupplyꢀPin GND is the device internal ground.
Integrated Silicon Solution, Inc. — www.issi.comꢀ
3
Rev. C
08/07/09
IS42S16400E
FUNCTION (InꢀDetail)
READ
A0-A11ꢀareꢀaddressꢀinputsꢀsampledꢀduringꢀtheꢀACTIVEꢀ
(row-addressꢀA0-A11)ꢀandꢀREAD/WRITEꢀcommandꢀ(A0-A7ꢀ
withꢀA10ꢀdefiningꢀautoꢀPRECHARGE). A10 is sampled during
aꢀPRECHARGEꢀcommandꢀtoꢀdetermineꢀifꢀallꢀbanksꢀareꢀtoꢀ
beꢀPRECHARGEDꢀ(A10ꢀHIGH)ꢀorꢀbankꢀselectedꢀbyꢀBA0,ꢀ
BA1ꢀ(LOW).ꢀꢀTheꢀaddressꢀinputsꢀalsoꢀprovideꢀtheꢀop-codeꢀ
duringꢀaꢀLOADꢀMODEꢀREGISTERꢀcommand.
TheꢀREADꢀcommandꢀselectsꢀtheꢀbankꢀfromꢀBA0,ꢀBA1ꢀinputsꢀ
and starts a burst read access to an active row. Inputs
A0-A7ꢀprovidesꢀtheꢀstartingꢀcolumnꢀlocation.ꢀꢀWhenꢀA10ꢀisꢀ
HIGH,ꢀthisꢀcommandꢀfunctionsꢀasꢀanꢀAUTOꢀPRECHARGEꢀ
command. When the auto precharge is selected, the row
beingꢀaccessedꢀwillꢀbeꢀprechargedꢀatꢀtheꢀendꢀofꢀtheꢀREADꢀ
burst.ꢀTheꢀrowꢀwillꢀremainꢀopenꢀforꢀsubsequentꢀaccessesꢀ
whenꢀAUTOꢀPRECHARGEꢀisꢀnotꢀselected.ꢀꢀDQ’sꢀreadꢀ
dataꢀisꢀsubjectꢀtoꢀtheꢀlogicꢀlevelꢀonꢀtheꢀDQMꢀinputsꢀtwoꢀ
clocksꢀearlier.ꢀWhenꢀaꢀgivenꢀDQMꢀsignalꢀwasꢀregisteredꢀ
HIGH,ꢀtheꢀcorrespondingꢀDQ’sꢀwillꢀbeꢀHigh-Zꢀtwoꢀclocksꢀ
later.ꢀDQ’sꢀwillꢀprovideꢀvalidꢀdataꢀwhenꢀtheꢀDQMꢀsignalꢀ
wasꢀregisteredꢀLOW.
BankꢀSelectꢀAddressꢀ(BA0ꢀandꢀBA1) defines which bank
theꢀACTIVE,ꢀREAD,ꢀWRITEꢀorꢀPRECHARGEꢀcommandꢀ
is being applied.
CAS,inconjunctionwiththeRASandWE,formsthedevice
command.ꢀSeeꢀtheꢀ“CommandꢀTruthꢀTable”ꢀforꢀdetailsꢀonꢀ
device commands.
WRITE
TheꢀCKEꢀinputꢀdeterminesꢀwhetherꢀtheꢀCLKꢀinputꢀisꢀen-
abled.ꢀTheꢀnextꢀrisingꢀedgeꢀofꢀtheꢀCLKꢀsignalꢀwillꢀbeꢀvalidꢀ
whenꢀisꢀCKEꢀHIGHꢀandꢀinvalidꢀwhenꢀLOW.ꢀWhenꢀCKEꢀisꢀ
LOW,ꢀtheꢀdeviceꢀwillꢀbeꢀinꢀeitherꢀpower-downꢀmode,ꢀCLOCKꢀ
SUSPENDꢀmode,ꢀorꢀSELF-REFRESHꢀmode.ꢀCKEꢀisꢀanꢀ
asynchronous input.
A burst write access to an active row is initiated with the
WRITEꢀcommand.ꢀꢀBA0,ꢀBA1ꢀinputsꢀselectsꢀtheꢀbank,ꢀ
and the starting column location is provided by inputs
A0-A7.ꢀWhetherꢀorꢀnotꢀAUTO-PRECHARGEꢀisꢀusedꢀisꢀ
determined by A10.
CLKꢀisꢀtheꢀmasterꢀclockꢀinputꢀforꢀthisꢀdevice.ꢀExceptꢀforꢀ
CKE,ꢀallꢀinputsꢀtoꢀthisꢀdeviceꢀareꢀacquiredꢀinꢀsynchroniza-
tion with the rising edge of this pin.
Theꢀrowꢀbeingꢀaccessedꢀwillꢀbeꢀprechargedꢀatꢀtheꢀendꢀofꢀ
theꢀWRITEꢀburst,ꢀifꢀAUTOꢀPRECHARGEꢀisꢀselected.ꢀIfꢀ
AUTOꢀPRECHARGEꢀisꢀnotꢀselected,ꢀtheꢀrowꢀwillꢀremainꢀ
openꢀforꢀsubsequentꢀaccesses.
TheꢀCS input determines whether command input is en-
abled within the device. Command input is enabled when
CS isꢀLOW,ꢀandꢀdisabledꢀwithꢀCS isꢀHIGH.ꢀTheꢀdeviceꢀ
remains in the previous state when CS isꢀHIGH.ꢀDQ0ꢀtoꢀ
DQ15ꢀareꢀDQꢀpins.ꢀDQꢀthroughꢀtheseꢀpinsꢀcanꢀbeꢀcontrolledꢀ
inꢀbyteꢀunitsꢀusingꢀtheꢀLDQMꢀandꢀUDQMꢀpins.
A memory array is written with corresponding input data
onꢀDQ’sꢀandꢀDQMꢀinputꢀlogicꢀlevelꢀappearingꢀatꢀtheꢀsameꢀ
time.ꢀꢀDataꢀwillꢀbeꢀwrittenꢀtoꢀmemoryꢀwhenꢀDQMꢀsignalꢀisꢀ
LOW.ꢀꢀWhenꢀDQMꢀisꢀHIGH,ꢀtheꢀcorrespondingꢀdataꢀinputsꢀ
willꢀbeꢀignored,ꢀandꢀaꢀWRITEꢀwillꢀnotꢀbeꢀexecutedꢀtoꢀthatꢀ
byte/column location.
LDQMꢀandꢀUDQMꢀcontrolꢀtheꢀlowerꢀandꢀupperꢀbytesꢀofꢀ
theꢀDQꢀbuffers.ꢀInꢀreadꢀmode,ꢀLDQMꢀandꢀUDQMꢀcontrolꢀ
theꢀ outputꢀ buffer.ꢀWhenꢀ LDQMꢀ orꢀ UDQMꢀ isꢀ LOW,ꢀ theꢀ
correspondingꢀbufferꢀbyteꢀisꢀenabled,ꢀandꢀwhenꢀHIGH,ꢀ
disabled.ꢀTheꢀoutputsꢀgoꢀtoꢀtheꢀHIGHꢀImpedanceꢀStateꢀ
whenꢀLDQM/UDQMꢀisꢀHIGH.ꢀThisꢀfunctionꢀcorrespondsꢀ
to OE inꢀconventionalꢀDRAMs.ꢀInꢀwriteꢀmode,ꢀLDQMꢀandꢀ
UDQMꢀcontrolꢀtheꢀinputꢀbuffer.ꢀWhenꢀLDQMꢀorꢀUDQMꢀisꢀ
LOW,ꢀtheꢀcorrespondingꢀbufferꢀbyteꢀisꢀenabled,ꢀandꢀdataꢀ
canꢀbeꢀwrittenꢀtoꢀtheꢀdevice.ꢀWhenꢀLDQMꢀorꢀUDQMꢀisꢀ
HIGH,ꢀinputꢀdataꢀisꢀmaskedꢀandꢀcannotꢀbeꢀwrittenꢀtoꢀtheꢀ
device.
PRECHARGE
TheꢀPRECHARGEꢀcommandꢀisꢀusedꢀtoꢀdeactivateꢀtheꢀ
open row in a particular bank or the open row in all banks.
BA0,ꢀBA1ꢀcanꢀbeꢀusedꢀtoꢀselectꢀwhichꢀbankꢀisꢀprechargedꢀ
orꢀ theyꢀ areꢀ treatedꢀ asꢀ “Don’tꢀ Care”.ꢀ ꢀ A10ꢀ determinedꢀ
whetherꢀoneꢀorꢀallꢀbanksꢀareꢀprecharged.ꢀAfterꢀexecut-
ingꢀ thisꢀ command,ꢀ theꢀ nextꢀ commandꢀ forꢀ theꢀ selectedꢀ
banks(s)ꢀisꢀexecutedꢀafterꢀpassageꢀofꢀtheꢀperiodꢀtRP, which
isꢀtheꢀperiodꢀrequiredꢀforꢀbankꢀprecharging.ꢀꢀꢀOnceꢀaꢀbankꢀ
has been precharged, it is in the idle state and must be
activatedꢀpriorꢀtoꢀanyꢀREADꢀorꢀWRITEꢀcommandsꢀbeingꢀ
issued to that bank.
RAS, in conjunction with CAS and WE , forms the device
command.ꢀSeeꢀtheꢀ“CommandꢀTruthꢀTable”ꢀitemꢀforꢀdetailsꢀ
on device commands.
AUTO PRECHARGE
WE , in conjunction with RAS and CAS , forms the device
command.ꢀSeeꢀtheꢀ“CommandꢀTruthꢀTable”ꢀitemꢀforꢀdetailsꢀ
on device commands.
TheꢀAUTOꢀPRECHARGEꢀfunctionꢀensuresꢀthatꢀtheꢀpre-
charge is initiated at the earliest valid stage within a burst.
Thisꢀfunctionꢀallowsꢀforꢀindividual-bankꢀprechargeꢀwithoutꢀ
requiringꢀanꢀexplicitꢀcommand.ꢀꢀA10ꢀtoꢀenablesꢀtheꢀAUTOꢀ
PRECHARGEꢀfunctionꢀinꢀconjunctionꢀwithꢀaꢀspecificꢀREADꢀ
orꢀWRITEꢀcommand.ꢀꢀForꢀeachꢀindividualꢀREADꢀorꢀWRITEꢀ
command, auto precharge is either enabled or disabled.
VDDq is the output buffer power supply.
VDD is the device internal power supply.
GNDq is the output buffer ground.
GNDꢀisꢀtheꢀdeviceꢀinternalꢀground.
4ꢀ
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
BURST TERMINATE
AUTOꢀPRECHARGEꢀdoesꢀnotꢀapplyꢀexceptꢀinꢀfull-pageꢀ
burstꢀ mode.ꢀ Uponꢀ completionꢀ ofꢀ theꢀ READꢀ orꢀWRITEꢀ
burst, a precharge of the bank/row that is addressed is
automatically performed.
TheꢀBURSTꢀTERMINATEꢀcommandꢀforciblyꢀterminatesꢀ
the burst read and write operations by truncating either
fixed-lengthꢀ orꢀ full-pageꢀ burstsꢀ andꢀ theꢀ mostꢀ recentlyꢀ
registeredꢀREADꢀorꢀWRITEꢀcommandꢀpriorꢀtoꢀtheꢀBURSTꢀ
TERMINATE.
AUTO REFRESH COMMAND
COMMAND INHIBIT
COMMANDꢀINHIBITꢀpreventsꢀnewꢀcommandsꢀfromꢀbeingꢀ
executed.ꢀOperationsꢀinꢀprogressꢀareꢀnotꢀaffected,ꢀapartꢀ
fromꢀwhetherꢀtheꢀCLKꢀsignalꢀisꢀenabled
ThisꢀcommandꢀexecutesꢀtheꢀAUTOꢀREFRESHꢀoperation.ꢀ
Theꢀrowꢀaddressꢀandꢀbankꢀtoꢀbeꢀrefreshedꢀareꢀautomaticallyꢀ
generatedꢀduringꢀthisꢀoperation.ꢀ Theꢀstipulatedꢀperiodꢀ(tr c )ꢀisꢀ
requiredꢀforꢀaꢀsingleꢀrefreshꢀoperation,ꢀandꢀnoꢀotherꢀcom-
mandsꢀcanꢀbeꢀexecutedꢀduringꢀthisꢀperiod.ꢀ Thisꢀcommandꢀisꢀ
executedꢀatꢀleastꢀ4096ꢀtimesꢀeveryꢀ64ms.ꢀDuringꢀanꢀAUTOꢀ
REFRESHꢀcommand,ꢀaddressꢀbitsꢀareꢀ“Don’tꢀCare”.ꢀꢀThisꢀ
commandꢀcorrespondsꢀtoꢀCBRꢀAuto-refresh.
NO OPERATION
When CSꢀisꢀlow,ꢀtheꢀNOPꢀcommandꢀpreventsꢀunwantedꢀ
commands from being registered during idle or wait
states.
SELF REFRESH
LOAD MODE REGISTER
DuringꢀtheꢀSELFꢀREFRESHꢀoperation,ꢀtheꢀrowꢀaddressꢀtoꢀ
be refreshed, the bank, and the refresh interval are gen-
eratedꢀautomaticallyꢀinternally.ꢀꢀSELFꢀREFRESHꢀcanꢀbeꢀ
usedꢀtoꢀretainꢀdataꢀinꢀtheꢀSDRAMꢀwithoutꢀexternalꢀclocking,ꢀ
evenꢀifꢀtheꢀrestꢀofꢀtheꢀsystemꢀisꢀpoweredꢀdown.ꢀTheꢀSELFꢀ
REFRESHꢀoperationꢀisꢀstartedꢀbyꢀdroppingꢀtheꢀCKEꢀpinꢀ
fromꢀHIGHꢀtoꢀLOW.ꢀDuringꢀtheꢀSELFꢀREFRESHꢀoperationꢀ
allꢀotherꢀinputsꢀtoꢀtheꢀSDRAMꢀbecomeꢀ“Don’tꢀCare”.ꢀTheꢀ
device must remain in self refresh mode for a minimum
periodꢀequalꢀtoꢀtr a s or may remain in self refresh mode
forꢀanꢀindefiniteꢀperiodꢀbeyondꢀthat.ꢀTheꢀSELF-REFRESHꢀ
operationꢀcontinuesꢀasꢀlongꢀasꢀtheꢀCKEꢀpinꢀremainsꢀLOWꢀ
andꢀthereꢀisꢀnoꢀneedꢀforꢀexternalꢀcontrolꢀofꢀanyꢀotherꢀpins.ꢀ
Theꢀnextꢀcommandꢀcannotꢀbeꢀexecutedꢀuntilꢀtheꢀdeviceꢀ
internal recovery period (tr c )ꢀ hasꢀ elapsed.ꢀ Onceꢀ CKEꢀ
goesꢀHIGH,ꢀtheꢀNOPꢀcommandꢀmustꢀbeꢀissuedꢀ(minimum
ofꢀ twoꢀclocks) to provide time for the completion of any
internalꢀrefreshꢀinꢀprogress.ꢀAfterꢀtheꢀself-refresh,ꢀsinceꢀitꢀ
is impossible to determine the address of the last row to
beꢀrefreshed,ꢀanꢀAUTO-REFRESHꢀshouldꢀimmediatelyꢀbeꢀ
performed for all addresses.
DuringꢀtheꢀLOADꢀMODEꢀREGISTERꢀcommandꢀtheꢀmodeꢀ
registerꢀisꢀloadedꢀfromꢀA0-A11.ꢀꢀThisꢀcommandꢀcanꢀonlyꢀ
be issued when all banks are idle.
ACTIVE COMMAND
Whenꢀ theꢀ ACTIVEꢀ COMMANDꢀ isꢀ activated,ꢀ BA0,ꢀ BA1ꢀ
inputs selects a bank to be accessed, and the address
inputsꢀonꢀA0-A11ꢀselectsꢀtheꢀrow.ꢀꢀꢀUntilꢀaꢀPRECHARGEꢀ
command is issued to the bank, the row remains open
for accesses.
Integrated Silicon Solution, Inc. — www.issi.comꢀ
5
Rev. C
08/07/09
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
Active
High-Z
Hꢀ
—ꢀ
IS42S16400E
TRUTH TABLE – COMMANDS AND DQM OPERATION(1)
FUNCTION
CS
Hꢀ
Lꢀ
RAS CAS
WE DQM
ADDR
Xꢀ
DQs
COMMANDꢀINHIBITꢀ(NOP)ꢀ
Xꢀ
Hꢀ
Lꢀ
Xꢀ
Hꢀ
Hꢀ
Lꢀ
Xꢀ
Hꢀ
Hꢀ
Hꢀ
Lꢀ
Xꢀ
Xꢀ
X
X
NOꢀOPERATIONꢀ(NOP)ꢀ
Xꢀ
ACTIVEꢀ(Selectꢀbankꢀandꢀactivateꢀrow)(3)ꢀ
READꢀ(Selectꢀbank/column,ꢀstartꢀREADꢀburst)(4)
WRITEꢀ(Selectꢀbank/column,ꢀstartꢀWRITEꢀburst)(4)ꢀ Lꢀ
BURSTꢀTERMINATEꢀ Lꢀ
PRECHARGEꢀ(Deactivateꢀrowꢀinꢀbankꢀorꢀbanks)(5)ꢀ Lꢀ
Lꢀ
Xꢀ
Bank/Rowꢀ
Bank/Colꢀ
Bank/Colꢀ
Xꢀ
X
ꢀ
Lꢀ
Hꢀ
Hꢀ
Hꢀ
Lꢀ
L/H(8)ꢀ
L/H(8)ꢀ
Xꢀ
X
Lꢀ
Valid
Active
X
Hꢀ
Hꢀ
Lꢀ
Lꢀ
Lꢀ
Xꢀ
Codeꢀ
Xꢀ
AUTOꢀREFRESHꢀorꢀSELFꢀREFRESH(6,7)
ꢀ
Lꢀ
Lꢀ
Hꢀ
Xꢀ
X
(Enterꢀselfꢀrefreshꢀmode)
LOADꢀMODEꢀREGISTER(2)ꢀ
WriteꢀEnable/OutputꢀEnable(8)ꢀ
WriteꢀInhibit/OutputꢀHigh-Z(8)ꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Xꢀ
Lꢀ
Op-Codeꢀ
—ꢀ
X
NOTES:
1.ꢀ CKEꢀisꢀHIGHꢀforꢀallꢀcommandsꢀexceptꢀSELFꢀREFRESH.
2.ꢀ A0-A11ꢀdefineꢀtheꢀop-codeꢀwrittenꢀtoꢀtheꢀmodeꢀregister.
3.ꢀ A0-A11ꢀprovideꢀrowꢀaddress,ꢀandꢀBA0,ꢀBA1ꢀdetermineꢀwhichꢀbankꢀisꢀmadeꢀactive.
4.ꢀ A0-A7ꢀ(x16)ꢀprovideꢀcolumnꢀaddress;ꢀA10ꢀHIGHꢀenablesꢀtheꢀautoꢀprechargeꢀfeatureꢀ(nonpersistent),ꢀwhileꢀA10ꢀLOWꢀdisablesꢀ
autoꢀprecharge;ꢀBA0,ꢀBA1ꢀdetermineꢀwhichꢀbankꢀisꢀbeingꢀreadꢀfromꢀorꢀwrittenꢀto.
5.ꢀ A10ꢀLOW:ꢀBA0,ꢀBA1ꢀdetermineꢀtheꢀbankꢀbeingꢀprecharged.ꢀA10ꢀHIGH:ꢀAllꢀbanksꢀprechargedꢀandꢀBA0,ꢀBA1ꢀareꢀ“Don’tꢀCare.”
6.ꢀ AUTOꢀREFRESHꢀifꢀCKEꢀisꢀHIGH,ꢀSELFꢀREFRESHꢀifꢀCKEꢀisꢀLOW.
7.ꢀ Internalꢀrefreshꢀcounterꢀcontrolsꢀrowꢀaddressing;ꢀallꢀinputsꢀandꢀI/Osꢀareꢀ“Don’tꢀCare”ꢀexceptꢀforꢀCKE.
8.ꢀ ActivatesꢀorꢀdeactivatesꢀtheꢀDQsꢀduringꢀWRITEsꢀ(zero-clockꢀdelay)ꢀandꢀREADsꢀ(two-clockꢀdelay).
6
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
TRUTH TABLE – CKE (1-4)
CURRENT STATE
COMMANDn
ACTIONn
CKEn-1
CKEn
Power-Downꢀ
Xꢀ
MaintainꢀPower-Downꢀ
MaintainꢀSelfꢀRefreshꢀ
MaintainꢀClockꢀSuspendꢀ
ExitꢀPower-Downꢀ
ExitꢀSelfꢀRefreshꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Hꢀ
Hꢀ
Hꢀ
L
L
SelfꢀRefreshꢀ
Xꢀ
ClockꢀSuspendꢀ
Power-Down(5)ꢀ
SelfꢀRefresh(6)ꢀ
Clock Suspend(7)ꢀ
AllꢀBanksꢀIdleꢀ
AllꢀBanksꢀIdleꢀ
ReadingꢀorꢀWritingꢀ
Xꢀ
L
COMMANDꢀINHIBITꢀorꢀNOPꢀ
COMMANDꢀINHIBITꢀorꢀNOPꢀ
Xꢀ
H
H
H
L
ExitꢀClockꢀSuspendꢀ
Power-DownꢀEntryꢀ
SelfꢀRefreshꢀEntryꢀ
ClockꢀSuspendꢀEntryꢀ
COMMANDꢀINHIBITꢀorꢀNOPꢀ
AUTOꢀREFRESHꢀ
VALIDꢀ
L
L
See TRUTH TABLE – CURRENT STATE BANK n, COMMAND TO BANK n
ꢀ
Hꢀ
H
NOTES:
1.ꢀ CKEnꢀisꢀtheꢀlogicꢀstateꢀofꢀCKEꢀatꢀclockꢀedgeꢀn;ꢀCKEn-1 wasꢀtheꢀstateꢀofꢀCKEꢀatꢀtheꢀpreviousꢀclockꢀedge.ꢀ
2.ꢀ CurrentꢀstateꢀisꢀtheꢀstateꢀofꢀtheꢀSDRAMꢀimmediatelyꢀpriorꢀtoꢀclockꢀedgeꢀn.
3.ꢀ COMMANDnꢀisꢀtheꢀcommandꢀregisteredꢀatꢀclockꢀedgeꢀn,ꢀandꢀACTONnꢀisꢀaꢀresultꢀofꢀCOMMANDn.
4.ꢀ Allꢀstatesꢀandꢀsequencesꢀnotꢀshownꢀareꢀillegalꢀorꢀreserved.
5.ꢀ Exitingꢀpower-downꢀatꢀclockꢀedgeꢀn will put the device in the all banks idle state in time for clock edge n+1 (provided that tc k s is
met)
.
6.ꢀ Exitingꢀselfꢀrefreshꢀatꢀclockꢀedgeꢀn will put the device in all banks idle state once tx s r ꢀisꢀmet.ꢀCOMMANDꢀINHIBITꢀorꢀNOPꢀ
commands should be issued on clock edges occurring during the tx s r ꢀperiod.ꢀAꢀminimumꢀofꢀtwoꢀNOPꢀcommandsꢀmustꢀbeꢀsentꢀ
during tx s r period.
7.ꢀ Afterꢀexitingꢀclockꢀsuspendꢀatꢀclockꢀedgeꢀn,ꢀtheꢀdeviceꢀwillꢀresumeꢀoperationꢀandꢀrecognizeꢀtheꢀnextꢀcommandꢀatꢀclockꢀedgeꢀ
n+1.
TRUTH TABLE – CURRENT STATE BANK n, COMMAND TO BANK n (1-6)
CURRENTꢀSTATE
ꢀ
COMMANDꢀ(ACTION)
CS RAS CAS WE
Anyꢀ
COMMANDꢀINHIBITꢀ(NOP/Continueꢀpreviousꢀoperation)
ꢀ
Hꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Xꢀ
Hꢀ
Lꢀ
Xꢀ
Hꢀ
Hꢀ
Lꢀ
X
H
H
H
L
ꢀ
NOꢀOPERATIONꢀ(NOP/Continueꢀpreviousꢀoperation)
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
ꢀAUTOꢀREFRESH(7)ꢀ
ꢀ
Idleꢀ
ꢀ
Lꢀ
ꢀ
LOADꢀMODEꢀREGISTER(7)ꢀ
PRECHARGE(11)ꢀ
Lꢀ
Lꢀ
ꢀ
Lꢀ
Hꢀ
Lꢀ
L
RowꢀActiveꢀ
ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀREADꢀburst)(10)ꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀWRITEꢀburst)(10)ꢀ
PRECHARGEꢀ(Deactivateꢀrowꢀinꢀbankꢀorꢀbanks)(8)ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀREADꢀburst)(10)ꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀWRITEꢀburst)(10)ꢀ
PRECHARGEꢀ(TruncateꢀREADꢀburst,ꢀstartꢀPRECHARGE)(8)ꢀ
BURSTꢀTERMINATE(9)ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀREADꢀburst)(10)ꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀWRITEꢀburst)(10)ꢀ
PRECHARGEꢀ(TruncateꢀWRITEꢀburst,ꢀstartꢀPRECHARGE)(8)ꢀ
BURSTꢀTERMINATE(9)ꢀ
Hꢀ
Hꢀ
Lꢀ
H
L
Lꢀ
ꢀ
Hꢀ
Lꢀ
L
Readꢀ
Hꢀ
Hꢀ
Lꢀ
H
L
(Autoꢀ
Lꢀ
Prechargeꢀ
Disabled)ꢀ
Writeꢀ
Hꢀ
Hꢀ
Lꢀ
L
Hꢀ
Hꢀ
Hꢀ
Lꢀ
L
H
L
(Autoꢀ
Lꢀ
Prechargeꢀ
Hꢀ
Hꢀ
L
Disabled)ꢀ
Hꢀ
L
NOTE:
ꢀ 1.ꢀThisꢀtableꢀappliesꢀwhenꢀCKEꢀn-1ꢀwasꢀHIGHꢀandꢀCKEꢀnꢀisꢀHIGHꢀ(seeꢀTruthꢀTableꢀ-ꢀCKE)ꢀandꢀafterꢀtx s r has been met (if the
previous state was SELFꢀREFRESH).
ꢀ 2.ꢀThisꢀtableꢀisꢀbank-specific,ꢀexceptꢀwhereꢀnoted;ꢀi.e.,ꢀtheꢀcurrentꢀstateꢀisꢀforꢀaꢀspecificꢀbankꢀandꢀtheꢀcommandsꢀshownꢀareꢀthoseꢀ
allowedꢀtoꢀbeꢀissuedꢀtoꢀthatꢀbankꢀwhenꢀinꢀthatꢀstate.ꢀExceptionsꢀareꢀcoveredꢀinꢀtheꢀnotesꢀbelow.
Integrated Silicon Solution, Inc. — www.issi.com
7
Rev. C
08/07/09
IS42S16400E
ꢀ 3.ꢀCurrentꢀstateꢀdefinitions:
ꢀ
ꢀ
Idle:ꢀTheꢀbankꢀhasꢀbeenꢀprecharged,ꢀandꢀtr p has been met.
RowꢀActive:ꢀAꢀrowꢀinꢀtheꢀbankꢀhasꢀbeenꢀactivated,ꢀandꢀtr c D has been met. No data bursts/accesses and no register
accesses are in progress.
ꢀ
ꢀ
Read:ꢀAꢀREADꢀburstꢀhasꢀbeenꢀinitiated,ꢀwithꢀautoꢀprechargeꢀdisabled,ꢀandꢀhasꢀnotꢀyetꢀterminatedꢀorꢀbeenꢀtermi-
nated.
Write:ꢀAꢀWRITEꢀburstꢀhasꢀbeenꢀinitiated,ꢀwithꢀautoꢀprechargeꢀdisabled,ꢀandꢀhasꢀnotꢀyetꢀterminatedꢀorꢀbeenꢀtermi-
nated.
ꢀ 4.ꢀTheꢀfollowingꢀstatesꢀmustꢀnotꢀbeꢀinterruptedꢀbyꢀaꢀcommandꢀissuedꢀtoꢀtheꢀsameꢀbank.ꢀCOMMANDꢀINHIBITꢀorꢀNOPꢀcommands,ꢀ
or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable com-
mandsꢀtoꢀtheꢀotherꢀbankꢀareꢀdeterminedꢀbyꢀitsꢀcurrentꢀstateꢀandꢀCURRENTꢀSTATEꢀBANKꢀnꢀtruthꢀtables.
ꢀ
ꢀ
ꢀ
Precharging:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀPRECHARGEꢀcommandꢀandꢀendsꢀwhenꢀtr p ꢀisꢀmet.ꢀOnceꢀtr p is met, the bank
will be in the idle state.
RowꢀActivating:ꢀStartsꢀwithꢀregistrationꢀofꢀanꢀACTIVEꢀcommandꢀandꢀendsꢀwhenꢀtr c D ꢀisꢀmet.ꢀOnceꢀtr c D is met, the bank will
be in the row active state.
Readꢀw/Auto
PrechargeꢀEnabled:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀREADꢀcommandꢀwithꢀautoꢀprechargeꢀenabledꢀandꢀendsꢀwhenꢀtr p has been
met.ꢀOnceꢀtr p is met, the bank will be in the idle state.
Write w/Auto
PrechargeꢀEnabled:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀWRITEꢀcommandꢀwithꢀautoꢀprechargeꢀenabledꢀandꢀendsꢀwhenꢀtr p has been
met.ꢀOnceꢀtr p is met, the bank will be in the idle state.
ꢀ 5.ꢀTheꢀfollowingꢀstatesꢀmustꢀnotꢀbeꢀinterruptedꢀbyꢀanyꢀexecutableꢀcommand;ꢀCOMMANDꢀINHIBITꢀorꢀNOPꢀcommandsꢀmustꢀbeꢀ
applied on each positive clock edge during these states.
ꢀ
Refreshing:ꢀStartsꢀwithꢀregistrationꢀofꢀanꢀAUTOꢀREFRESHꢀcommandꢀandꢀendsꢀwhenꢀtr c ꢀisꢀmet.ꢀOnceꢀtr c is met, the
SDRAMꢀwillꢀbeꢀinꢀtheꢀallꢀbanksꢀidleꢀstate.
AccessingꢀMode
ꢀ
Register:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀLOADꢀMODEꢀREGISTERꢀcommandꢀandꢀendsꢀwhenꢀtm r D ꢀhasꢀbeenꢀmet.ꢀOnceꢀ
tm r D ꢀisꢀmet,ꢀtheꢀSDRAMꢀwillꢀbeꢀinꢀtheꢀallꢀbanksꢀidleꢀstate.
PrechargingꢀAll:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀPRECHARGEꢀALLꢀcommandꢀandꢀendsꢀwhenꢀtr p ꢀisꢀmet.ꢀOnceꢀtr p is met, all
banks will be in the idle state.
ꢀ 6.ꢀAllꢀstatesꢀandꢀsequencesꢀnotꢀshownꢀareꢀillegalꢀorꢀreserved.
ꢀ 7.ꢀNotꢀbank-specific;ꢀrequiresꢀthatꢀallꢀbanksꢀareꢀidle.
ꢀ 8.ꢀMayꢀorꢀmayꢀnotꢀbeꢀbank-specific;ꢀifꢀallꢀbanksꢀareꢀtoꢀbeꢀprecharged,ꢀallꢀmustꢀbeꢀinꢀaꢀvalidꢀstateꢀforꢀprecharging.
ꢀ 9.ꢀNotꢀbank-specific;ꢀBURSTꢀTERMINATEꢀaffectsꢀtheꢀmostꢀrecentꢀREADꢀorꢀWRITEꢀburst,ꢀregardlessꢀofꢀbank.
ꢀ10.ꢀREADsꢀorꢀWRITEsꢀlistedꢀinꢀtheꢀCommandꢀ(Action)ꢀcolumnꢀincludeꢀREADsꢀorꢀWRITEsꢀwithꢀautoꢀprechargeꢀenabledꢀandꢀ
READsꢀorꢀWRITEsꢀwithꢀautoꢀprechargeꢀdisabled.
ꢀ11.ꢀDoesꢀnotꢀaffectꢀtheꢀstateꢀofꢀtheꢀbankꢀandꢀactsꢀasꢀaꢀNOPꢀtoꢀthatꢀbank.
8
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
(1-6)
TRUTH TABLE – CURRENT STATE BANK n, COMMAND TO BANK m
CURRENTꢀSTATE
ꢀ
COMMANDꢀ(ACTION)
CS RAS CAS WE
Anyꢀ
COMMANDꢀINHIBITꢀ(NOP/Continueꢀpreviousꢀoperation)ꢀ
NOꢀOPERATIONꢀ(NOP/Continueꢀpreviousꢀoperation)ꢀ
AnyꢀCommandꢀOtherwiseꢀAllowedꢀtoꢀBankꢀm
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀREADꢀburst)(7)ꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀWRITEꢀburst)(7)ꢀ
PRECHARGEꢀ
Hꢀ
Lꢀ
Xꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Lꢀ
Xꢀ
Hꢀ
Xꢀ
Lꢀ
Xꢀ
Hꢀ
Xꢀ
Hꢀ
Lꢀ
X
H
X
H
H
L
ꢀ
Idleꢀ
Rowꢀ
Activating,ꢀ
Active,ꢀorꢀ
Prechargingꢀ
Readꢀ
Hꢀ
Hꢀ
Lꢀ
Lꢀ
Hꢀ
Hꢀ
Lꢀ
L
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
Lꢀ
H
H
L
(Autoꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀREADꢀburst)(7,10)
ꢀ
Hꢀ
Hꢀ
Lꢀ
Prechargeꢀ
Disabled)ꢀ
Writeꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀWRITEꢀburst)(7,11)
PRECHARGE(9)ꢀ
ꢀ
Lꢀ
Hꢀ
Hꢀ
Lꢀ
L
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
Lꢀ
H
H
L
(Autoꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀREADꢀburst)(7,12)
ꢀ
Hꢀ
Hꢀ
Lꢀ
Prechargeꢀ
Disabled)ꢀ
Readꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀWRITEꢀburst)(7,13)
PRECHARGE(9)ꢀ
ꢀ
Lꢀ
Hꢀ
Hꢀ
Lꢀ
L
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
Lꢀ
H
H
L
(WithꢀAutoꢀ
Precharge)ꢀ
ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀREADꢀburst)(7,8,14)
ꢀ
Hꢀ
Hꢀ
Lꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀWRITEꢀburst)(7,8,15)
PRECHARGE(9)ꢀ
ꢀ
Lꢀ
Hꢀ
Hꢀ
Lꢀ
L
Writeꢀ
ACTIVEꢀ(Selectꢀandꢀactivateꢀrow)ꢀ
Lꢀ
H
H
L
(WithꢀAutoꢀ
Precharge)ꢀ
ꢀ
READꢀ(SelectꢀcolumnꢀandꢀstartꢀREADꢀburst)(7,8,16)
ꢀ
Hꢀ
Hꢀ
Lꢀ
WRITEꢀ(SelectꢀcolumnꢀandꢀstartꢀnewꢀWRITEꢀburst)(7,8,17)
PRECHARGE(9)ꢀ
ꢀ
Lꢀ
Hꢀ
L
NOTE:ꢀ
ꢀ 1.ꢀThisꢀtableꢀappliesꢀwhenꢀCKEꢀn-1ꢀwasꢀHIGHꢀandꢀCKEꢀnꢀisꢀHIGHꢀ(TruthꢀTableꢀ-ꢀCKE)ꢀandꢀafterꢀtx s r has been met (if the previ-
ousꢀstateꢀwasꢀselfꢀrefresh).
ꢀ 2.ꢀThisꢀtableꢀdescribesꢀalternateꢀbankꢀoperation,ꢀexceptꢀwhereꢀnoted;ꢀi.e.,ꢀtheꢀcurrentꢀstateꢀisꢀforꢀbankꢀn and the commands
shown are those allowed to be issued to bank m (assuming that bank m isꢀinꢀsuchꢀaꢀstateꢀthatꢀtheꢀgivenꢀcommandꢀisꢀallowable).ꢀExcep-
tions are covered in the notes below.
ꢀ 3.ꢀCurrentꢀstateꢀdefinitions:
ꢀ
ꢀ
Idle:ꢀTheꢀbankꢀhasꢀbeenꢀprecharged,ꢀandꢀtr p has been met.
RowꢀActive:ꢀAꢀrowꢀinꢀtheꢀbankꢀhasꢀbeenꢀactivated,ꢀandꢀtr c D has been met. No data bursts/accesses and no register
accesses are in progress.
ꢀ
ꢀ
ꢀ
Read:ꢀAꢀREADꢀburstꢀhasꢀbeenꢀinitiated,ꢀwithꢀautoꢀprechargeꢀdisabled,ꢀandꢀhasꢀnotꢀyetꢀterminatedꢀorꢀbeenꢀtermi-
nated.
Write:ꢀAꢀWRITEꢀburstꢀhasꢀbeenꢀinitiated,ꢀwithꢀautoꢀprechargeꢀdisabled,ꢀandꢀhasꢀnotꢀyetꢀterminatedꢀorꢀbeenꢀtermi-
nated.
Readꢀw/Auto
PrechargeꢀEnabled:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀREADꢀcommandꢀwithꢀautoꢀprechargeꢀenabled,ꢀandꢀendsꢀwhenꢀtr p has been
met.ꢀOnceꢀtr p is met, the bank will be in the idle state.
Write w/Auto
PrechargeꢀEnabled:ꢀStartsꢀwithꢀregistrationꢀofꢀaꢀWRITEꢀcommandꢀwithꢀautoꢀprechargeꢀenabled,ꢀandꢀendsꢀwhenꢀtr p has been
met.ꢀOnceꢀtr p is met, the bank will be in the idle state.
ꢀ 4.ꢀAUTOꢀREFRESH,ꢀSELFꢀREFRESHꢀandꢀLOADꢀMODEꢀREGISTERꢀcommandsꢀmayꢀonlyꢀbeꢀissuedꢀwhenꢀallꢀbanksꢀareꢀidle.
ꢀ 5.ꢀAꢀBURSTꢀTERMINATEꢀcommandꢀcannotꢀbeꢀissuedꢀtoꢀanotherꢀbank;ꢀitꢀappliesꢀtoꢀtheꢀbankꢀrepresentedꢀbyꢀtheꢀcurrentꢀstateꢀ
only.
ꢀ 6.ꢀAllꢀstatesꢀandꢀsequencesꢀnotꢀshownꢀareꢀillegalꢀorꢀreserved.
ꢀ 7.ꢀREADsꢀorꢀWRITEsꢀtoꢀbankꢀmꢀlistedꢀinꢀtheꢀCommandꢀ(Action)ꢀcolumnꢀincludeꢀREADsꢀorꢀWRITEsꢀwithꢀautoꢀprechargeꢀenabledꢀ
andꢀREADsꢀorꢀWRITEsꢀwithꢀautoꢀprechargeꢀdisabled.
ꢀ 8.ꢀCONCURRENTꢀAUTOꢀPRECHARGE:ꢀBankꢀnꢀwillꢀinitiateꢀtheꢀAUTOꢀPRECHARGEꢀcommandꢀwhenꢀitsꢀburstꢀhasꢀbeenꢀinter-
ruptedꢀbyꢀbankꢀm’sꢀburst.
Integrated Silicon Solution, Inc. — www.issi.com
9
Rev. C
08/07/09
IS42S16400E
ꢀ 9.ꢀBurstꢀinꢀbankꢀnꢀcontinuesꢀasꢀinitiated.
ꢀ10.ꢀForꢀaꢀREADꢀwithoutꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀ
theꢀREADꢀonꢀbankꢀn,ꢀCASꢀlatencyꢀlaterꢀ(ConsecutiveꢀREADꢀBursts).
ꢀ11.ꢀForꢀaꢀREADꢀwithoutꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀWRITEꢀtoꢀbankꢀmꢀwillꢀinter-
ruptꢀtheꢀREADꢀonꢀbankꢀnꢀwhenꢀregisteredꢀ(READꢀtoꢀWRITE).ꢀDQMꢀshouldꢀbeꢀusedꢀoneꢀclockꢀpriorꢀtoꢀtheꢀWRITEꢀcommandꢀtoꢀ
prevent bus contention.
ꢀ12.ꢀForꢀaꢀWRITEꢀwithoutꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀ
theꢀWRITEꢀonꢀbankꢀnꢀwhenꢀregisteredꢀ(WRITEꢀtoꢀREAD),ꢀwithꢀtheꢀdata-outꢀappearingꢀCASꢀlatencyꢀlater.ꢀTheꢀlastꢀvalidꢀWRITEꢀ
toꢀbankꢀnꢀwillꢀbeꢀdata-inꢀregisteredꢀoneꢀclockꢀpriorꢀtoꢀtheꢀREADꢀtoꢀbankꢀm.
ꢀ13.ꢀForꢀaꢀWRITEꢀwithoutꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀWRITEꢀtoꢀbankꢀmꢀwillꢀinter-
ruptꢀtheꢀWRITEꢀonꢀbankꢀnꢀwhenꢀregisteredꢀ(WRITEꢀtoꢀWRITE).ꢀTheꢀlastꢀvalidꢀWRITEꢀtoꢀbankꢀnꢀwillꢀbeꢀdata-inꢀregisteredꢀoneꢀ
clockꢀpriorꢀtoꢀtheꢀREADꢀtoꢀbankꢀm.
ꢀ14.ꢀForꢀaꢀREADꢀwithꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀtheꢀ
READꢀonꢀbankꢀn,ꢀCASꢀlatencyꢀlater.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀwhenꢀtheꢀREADꢀtoꢀbankꢀmꢀisꢀregisteredꢀ(FigꢀCAPꢀ
1).
ꢀ15.ꢀForꢀaꢀREADꢀwithꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀWRITEꢀtoꢀbankꢀmꢀwillꢀinterruptꢀ
theꢀREADꢀonꢀbankꢀnꢀwhenꢀregistered.ꢀDQMꢀshouldꢀbeꢀusedꢀtwoꢀclocksꢀpriorꢀtoꢀtheꢀWRITEꢀcommandꢀtoꢀpreventꢀbusꢀcontention.ꢀ
TheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀwhenꢀtheꢀWRITEꢀtoꢀbankꢀmꢀisꢀregisteredꢀ(FigꢀCAPꢀ2).
ꢀ16.ꢀForꢀaꢀWRITEꢀwithꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀ
theꢀWRITEꢀonꢀbankꢀnꢀwhenꢀregistered,ꢀwithꢀtheꢀdata-outꢀappearingꢀCASꢀlatencyꢀlater.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀ
after tWR is met, where tw r ꢀbeginsꢀwhenꢀtheꢀREADꢀtoꢀbankꢀmꢀisꢀregistered.ꢀTheꢀlastꢀvalidꢀWRITEꢀtoꢀbankꢀnꢀwillꢀbeꢀdata-inꢀregis-
teredꢀoneꢀclockꢀpriorꢀtoꢀtheꢀREADꢀtoꢀbankꢀmꢀ(FigꢀCAPꢀ3).
ꢀ17.ꢀForꢀaꢀWRITEꢀwithꢀautoꢀprechargeꢀinterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge),ꢀtheꢀWRITEꢀtoꢀbankꢀmꢀwillꢀinterruptꢀ
theꢀWRITEꢀonꢀbankꢀnꢀwhenꢀregistered.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀafterꢀtw r ꢀisꢀmet,ꢀwhereꢀtꢀWRꢀbeginsꢀwhenꢀtheꢀ
WRITEꢀtoꢀbankꢀmꢀisꢀregistered.ꢀTheꢀlastꢀvalidꢀWRITEꢀtoꢀbankꢀnꢀwillꢀbeꢀdataꢀregisteredꢀoneꢀclockꢀpriorꢀtoꢀtheꢀWRITEꢀtoꢀbankꢀmꢀ
(FigꢀCAPꢀ4).
10
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
VDD m a x ꢀ
VDDq m a x
ViNꢀ
Parameters
Rating
–1.0ꢀtoꢀ+4.6ꢀ
–1.0ꢀtoꢀ+4.6ꢀ
–1.0ꢀtoꢀVD D q +ꢀ0.5ꢀ
–1.0ꢀtoꢀVD D q +ꢀ0.5ꢀ
1ꢀ
Unit
V
V
V
V
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
MaximumꢀSupplyꢀVoltageꢀ
MaximumꢀSupplyꢀVoltageꢀforꢀOutputꢀBufferꢀ
InputꢀVoltageꢀ
OutputꢀVoltageꢀ
AllowableꢀPowerꢀDissipationꢀ
outputꢀShortedꢀCurrentꢀ
Vo u t ꢀ
PD m a x
Ic s
W
mA
50ꢀ
ꢀ
ꢀ
To p r
operatingꢀTemperatureꢀ
Com.ꢀ
Ind.ꢀ
0ꢀtoꢀ+70ꢀ
-40ꢀtoꢀ+85ꢀ
–65ꢀtoꢀ+150ꢀ
°Cꢀ
°C
°C
Ts t g ꢀ
StorageꢀTemperatureꢀ
ꢀ
DC RECOMMENDED OPERATING CONDITIONS(2) (AtꢀTaꢀ=ꢀ0ꢀtoꢀ+70°C)
Symbol
VDD, VDDqꢀ
Vihꢀ
Parameter
Min.
3.0ꢀ
2.0ꢀ
-0.3ꢀ
Typ.
3.3ꢀ
—ꢀ
Max.
3.6ꢀ
VD D +ꢀ0.3ꢀ
+0.8ꢀ
Unit
V
V
ꢀ
ꢀ
ꢀ
SupplyꢀVoltageꢀ
InputꢀHighꢀVoltage(3)ꢀ
InputꢀLowꢀVoltage(4)ꢀ
Vilꢀ
—ꢀ
V
CAPACITANCE CHARACTERISTICS(1,2) (AtꢀTaꢀ=ꢀ0ꢀtoꢀ+25°C,ꢀVD D ꢀ=ꢀVD D q ꢀ=ꢀ3.3ꢀ±ꢀ0.3V,ꢀfꢀ=ꢀ1ꢀMHz)
Symbol
CiNꢀ
Parameter
Typ.
—ꢀ
—ꢀ
Max.
3.8ꢀ
3.5ꢀ
6.5ꢀ
Unit
pF
pF
InputꢀCapacitance:ꢀAddressꢀandꢀControlꢀ
InputꢀCapacitance:ꢀ(CLK)ꢀ
DataꢀInput/OutputꢀCapacitance:ꢀI/O0-I/O15ꢀ
Cc l k ꢀ
CI/Oꢀ
ꢀ
—ꢀ
pF
Notes:
1.ꢀ StressꢀgreaterꢀthanꢀthoseꢀlistedꢀunderꢀABSOLUTEꢀMAXIMUMꢀRATINGSꢀmayꢀcauseꢀpermanentꢀdamageꢀtoꢀtheꢀdevice.ꢀThisꢀisꢀaꢀ
stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational
sectionsꢀofꢀthisꢀspecificationꢀisꢀnotꢀimplied.ꢀExposureꢀtoꢀabsoluteꢀmaximumꢀratingꢀconditionsꢀforꢀextendedꢀperiodsꢀmayꢀaffectꢀ
reliability.
2.ꢀ AllꢀvoltagesꢀareꢀreferencedꢀtoꢀGND.
3.ꢀꢀVih(max)ꢀ=ꢀVD D q ꢀ+ꢀ2.0Vꢀwithꢀaꢀpulseꢀwidthꢀ<ꢀ3ns.
4.ꢀꢀVil(min)ꢀ=ꢀGNDꢀ-ꢀ2.0Vꢀwithꢀaꢀpulseꢀwidthꢀ<ꢀ3ns.
Integrated Silicon Solution, Inc. — www.issi.com
11
Rev. C
08/07/09
i
Self-RefreshꢀCurrentꢀ
CKEꢀ≤ꢀ0.2Vꢀ
ꢀ
ꢀ
—ꢀ
—ꢀ
2ꢀ
mA
IS42S16400E
DC ELECTRICAL CHARACTERISTICS (RecommendedꢀOperationꢀConditionsꢀunlessꢀotherwiseꢀnoted.)
Symbol Parameter
Test Condition
Speed Min.
Max.
Unit
i
ꢀꢀ
ilꢀ
InputꢀLeakageꢀCurrentꢀ
ꢀ
0Vꢀ≤ꢀViN ≤ꢀVD D ,ꢀwithꢀpinsꢀotherꢀthanꢀ
theꢀtestedꢀpinꢀatꢀ0V
ꢀ
ꢀ
–5ꢀ
5ꢀ
µA
i
o l
ꢀ
OutputꢀLeakageꢀCurrentꢀ
OutputꢀHighꢀVoltageꢀLevelꢀ
OutputꢀLowꢀVoltageꢀLevelꢀ
Outputꢀisꢀdisabled,ꢀ0Vꢀ≤ Vo u t ≤ꢀVD D
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
–5ꢀ
2.4ꢀ
—ꢀ
5ꢀ
µAꢀ
V
V
o h
ꢀ
ꢀ
i
o u t ꢀ=ꢀ–2ꢀmAꢀ
o u t ꢀ=ꢀ+2ꢀmAꢀ
ꢀ
ꢀ
—ꢀ
0.4ꢀ
V
o l
ꢀ
i
V
ic c 1
OperatingꢀCurrent(1,2)
ꢀ
OneꢀBankꢀOperation,ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀCASꢀlatencyꢀ=ꢀ3ꢀꢀꢀCom.ꢀ
-6ꢀ
-7ꢀ
-7ꢀ
-6ꢀ
—ꢀ
—ꢀ
—
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—
95ꢀ
85ꢀ
145ꢀ
155
2ꢀ
4ꢀ
2
3ꢀ
mA
mA
mA
ꢀꢀ
ꢀ
BurstꢀLength=1ꢀ
ꢀ
ꢀ
ꢀ
t
ꢀ
t
ꢀ
Com.ꢀ
Ind.ꢀ
Ind.ꢀ
Com.ꢀ
Ind.ꢀ
Com.
Ind.ꢀ
t
I
r c ≥ tr c ꢀ(min.)ꢀ
o u t ꢀ=ꢀ0mAꢀ
i
ꢀꢀ
I
c c 2p
ꢀ
PrechargeꢀStandbyꢀCurrentꢀ CKEꢀ≤ Vil
ꢀ
(InꢀPower-DownꢀMode)
ꢀ
(m a x )ꢀ
c k ꢀ=ꢀ15nsꢀ
c k = ∞
mA
mA
mA
mA
ꢀ
c c 2p s
ꢀꢀ
ꢀ
—ꢀ
—ꢀ
i
I
c c 2N(3)ꢀ
PrechargeꢀStandbyꢀCurrentꢀ CKEꢀ≥ Vih
(InꢀNonꢀPower-DownꢀMode)
ꢀ
(
m iN )ꢀ
t
t
ꢀ
c k ꢀ=ꢀ15nsꢀ
c k = ∞ꢀ
ꢀ
Com.ꢀ
Ind.ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
20ꢀ
15ꢀ
15ꢀ
mA
mA
mA
c c 2N s
ꢀꢀ
ꢀ
i
c c 3p
ꢀ
ActiveꢀStandbyꢀCurrentꢀ
CKEꢀ≤ Vil
(m a x )ꢀ
t
c k = 10ns
Com.
Ind.
Com.ꢀ
Ind.ꢀ
—
—
—ꢀ
—ꢀ
—
—
—ꢀ
—ꢀ
7
7
5ꢀ
5ꢀ
mA
mA
mA
mA
ic c 3p s
ꢀ
(InꢀPower-DownꢀMode)ꢀ
ꢀ
ꢀ
ꢀ
tc k = ∞ꢀ
ꢀ
ꢀꢀ
i
I
ꢀꢀ
c c 3N(3)ꢀ
c c 3N s
ActiveꢀStandbyꢀCurrentꢀ
(InꢀNonꢀPower-DownꢀMode)
ꢀ
CKEꢀ≥ Vih
(
m iN )ꢀ
t
t
ꢀ
c k ꢀ=ꢀ15nsꢀ
c k = ∞ꢀ
ꢀ
Com.ꢀ
Ind.ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
30ꢀ
25ꢀ
25ꢀ
mA
mA
mA
ꢀ
i
ꢀꢀ
ꢀꢀ
ꢀꢀ
c c 4
c c 5
c c 6
ꢀ
ꢀ
ꢀ
OperatingꢀCurrentꢀ
t
c k = tc k
(
m iN )ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀCASꢀlatencyꢀ=ꢀ3ꢀ Com.ꢀ
-6ꢀ
-7ꢀ
-7ꢀ
-6ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
130ꢀ
100ꢀ
110ꢀ
140
mAꢀ
mAꢀ
mAꢀ
(InꢀBurstꢀMode)(1)ꢀ
I
o u t =ꢀ0mAꢀ
ꢀ
ꢀ
ꢀ
Com.ꢀ
Ind.ꢀ
Ind.ꢀꢀ
ꢀ
ꢀ
BLꢀ=ꢀ4;ꢀ4ꢀbanksꢀactivatedꢀ
ꢀ
i
Auto-RefreshꢀCurrentꢀ
t
t
ꢀ
ꢀ
r c = tr c
c l k = tc l k
(
m iN )ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀCASꢀlatencyꢀ=ꢀ3ꢀ Com.ꢀ
-6ꢀ
-7ꢀ
-7ꢀ
-6ꢀ
—ꢀ
—ꢀ
—ꢀ
—ꢀ
150ꢀ
130ꢀ
150ꢀ
170
mAꢀ
mAꢀ
mAꢀ
(m iN )ꢀꢀ
ꢀ
ꢀ
ꢀ
Com.ꢀ
Ind.ꢀ
Ind.ꢀ
ꢀꢀ
ꢀꢀ
ꢀ
ꢀ
Notes:
1.ꢀ Theseꢀareꢀtheꢀvaluesꢀatꢀtheꢀminimumꢀcycleꢀtime.ꢀSinceꢀtheꢀcurrentsꢀareꢀtransient,ꢀtheseꢀvaluesꢀdecreaseꢀasꢀtheꢀcycleꢀtimeꢀin-
creases.ꢀAlsoꢀnoteꢀthatꢀaꢀbypassꢀcapacitorꢀofꢀꢀatꢀꢀleastꢀꢀ0.01ꢀµFꢀshouldꢀbeꢀinsertedꢀbetweenꢀVD D ꢀandꢀGNDꢀforꢀeachꢀmemoryꢀchipꢀ
toꢀsuppressꢀpowerꢀsupplyꢀvoltageꢀnoiseꢀ(voltageꢀdrops)ꢀdueꢀtoꢀtheseꢀtransientꢀcurrents.
2. Icc1 and Icc4ꢀdependꢀonꢀtheꢀoutputꢀload.ꢀTheꢀmaximumꢀvaluesꢀforꢀIcc1 and Icc4 are obtained with the output open state.
3.ꢀꢀInputꢀsignalꢀchnageꢀonceꢀperꢀ30ns.
12
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
AC ELECTRICAL CHARACTERISTICS (1,2,3)
-6
-7
Symbol Parameter
Min.
Max.
Min.
Max.
Units
tc k 3ꢀ
tc k 2
ClockꢀCycleꢀTimeꢀ
CASꢀLatencyꢀ=ꢀ3ꢀ
CASꢀLatencyꢀ=ꢀ2ꢀ
6ꢀ
7.5ꢀ
—ꢀ
—ꢀ
7ꢀ
7.5ꢀ
—ꢀ
—ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
ta c 3ꢀ
ta c 2
AccessꢀTimeꢀFromꢀCLK(4,6)
CASꢀLatencyꢀ=ꢀ3ꢀ
CASꢀLatencyꢀ=ꢀ2ꢀ
—ꢀ
—ꢀ
5ꢀ
6ꢀ
—ꢀ
—ꢀ
5.4ꢀ
6ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
tc h iꢀ
tc l ꢀ
CLKꢀHIGHꢀLevelꢀWidthꢀ
CLKꢀLOWꢀLevelꢀWidthꢀ
OutputꢀDataꢀHoldꢀTime(6)
ꢀ
ꢀ
2ꢀ
2ꢀ
—ꢀ
—ꢀ
2.5ꢀ
2.5ꢀ
—ꢀ
—ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
to h 3ꢀ
to h 2
CASꢀLatencyꢀ=ꢀ3ꢀ
CAS Latencyꢀ=ꢀ2ꢀ
2.5ꢀ
2.5ꢀ
—ꢀ
—ꢀ
2.7ꢀ
3ꢀ
—ꢀ
—ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
tl z ꢀ
OutputꢀLOWꢀImpedanceꢀTimeꢀ
OutputꢀHIGHꢀImpedanceꢀTime(5) CASꢀLatencyꢀ=ꢀ3ꢀ
CASꢀLatencyꢀ=ꢀ2ꢀ
ꢀ
0ꢀ
—ꢀ
0ꢀ
—ꢀ
ꢀ
ꢀ
ns
th z 3ꢀ
th z 2
—ꢀ
—ꢀ
5ꢀ
6ꢀ
—ꢀ
—ꢀ
5.4ꢀ
6ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
tD s ꢀ
InputꢀDataꢀSetupꢀTimeꢀ
InputꢀDataꢀHoldꢀTimeꢀ
AddressꢀSetupꢀTimeꢀ
AddressꢀHoldꢀTimeꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
2ꢀ
1ꢀ
2ꢀ
1ꢀ
2ꢀ
1ꢀ
—ꢀ
—ꢀ
2ꢀ
1ꢀ
2ꢀ
1ꢀ
2ꢀ
1ꢀ
—ꢀ
—ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tD h ꢀ
ta s ꢀ
—ꢀ
—ꢀ
ta h ꢀ
—ꢀ
—ꢀ
tc k s ꢀ
tc k h ꢀ
tc k a ꢀ
tc s ꢀ
CKEꢀSetupꢀTimeꢀ
—ꢀ
—ꢀ
CKEꢀHoldꢀTimeꢀ
—ꢀ
—ꢀ
CKEꢀtoꢀCLKꢀRecoveryꢀDelayꢀTimeꢀ
1CLK+3
2ꢀ
—
1CLK+3
2.0ꢀ
1ꢀ
—
CommandꢀSetupꢀTimeꢀ(CS, RAS, CAS, WE,ꢀDQM)ꢀ ꢀ
—ꢀ
—ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
tc h ꢀ
CommandꢀHoldꢀTimeꢀ(CS, RAS, CAS, WE,ꢀDQM)ꢀ
CommandꢀPeriodꢀ(REFꢀtoꢀREFꢀ/ꢀACTꢀtoꢀACT)ꢀ
CommandꢀPeriodꢀ(ACTꢀtoꢀPRE)ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
1ꢀ
—ꢀ
—ꢀ
tr c ꢀ
60ꢀ
—ꢀ
63ꢀ
—ꢀ
tr a s ꢀ
tr p ꢀ
42ꢀ
100,000
—ꢀ
ꢀ
42ꢀ
100,000
—ꢀ
CommandꢀPeriodꢀ(PREꢀtoꢀACT)ꢀ
18ꢀ
20ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
tr c D ꢀ
tr r D ꢀ
ActiveꢀCommandꢀToꢀReadꢀ/ꢀWriteꢀCommandꢀDelayꢀTimeꢀ
CommandꢀPeriodꢀ(ACTꢀ[0]ꢀtoꢀACT[1])ꢀ
18ꢀ
—ꢀ
20ꢀ
—ꢀ
ꢀ
12ꢀ
—ꢀ
14ꢀ
—ꢀ
tD p l orꢀ
tw r ꢀ
InputꢀDataꢀToꢀPrechargeꢀ
CommandꢀDelayꢀtime
CASꢀLatencyꢀ=ꢀ3ꢀ
2CLKꢀ
—ꢀ
2CLKꢀ
—ꢀ
CAS Latencyꢀ=ꢀ2ꢀ
CASꢀLatencyꢀ=ꢀ3ꢀ
2CLKꢀ
—ꢀ
2CLKꢀ
—ꢀ
ꢀ
ꢀ
ns
tD a l ꢀ
InputꢀDataꢀToꢀActiveꢀ/ꢀRefreshꢀ
2CLK+tr p
—
2CLK+tr p
—
ns
ꢀ ꢀ ꢀ
CommandꢀDelayꢀtimeꢀ(DuringꢀAuto-Precharge)
CAS Latencyꢀ=ꢀ2ꢀ
2CLK+tr p
—
2CLK+tr p
—
ns
ns
ttꢀ
TransitionꢀTimeꢀ
ꢀ
ꢀ
1ꢀ
10ꢀ
64ꢀ
1ꢀ
10ꢀ
64ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
tr e f ꢀ
RefreshꢀCycleꢀTimeꢀ(4096)ꢀ
—ꢀ
—ꢀ
ms
Notes:
1.ꢀ Whenꢀpowerꢀisꢀfirstꢀapplied,ꢀmemoryꢀoperationꢀshouldꢀbeꢀstartedꢀ200ꢀµsꢀafterꢀVD D ꢀandꢀVD D q reach their stipulated voltages. Also
noteꢀthatꢀtheꢀpower-onꢀsequenceꢀmustꢀbeꢀexecutedꢀbeforeꢀstartingꢀmemoryꢀoperation.
2. measured with tt = 1 ns.
3.ꢀ Theꢀreferenceꢀlevelꢀisꢀ1.4ꢀVꢀwhenꢀmeasuringꢀinputꢀsignalꢀtiming.ꢀRiseꢀandꢀfallꢀtimesꢀareꢀmeasuredꢀbetweenꢀVih (min.)ꢀandꢀVil
(max.).
4.ꢀ Accessꢀtimeꢀisꢀmeasuredꢀatꢀ1.4Vꢀwithꢀtheꢀloadꢀshownꢀinꢀtheꢀfigureꢀbelow.
5.ꢀ Theꢀtimeꢀth z (max.)ꢀisꢀdefinedꢀasꢀtheꢀtimeꢀrequiredꢀforꢀtheꢀoutputꢀvoltageꢀtoꢀtransitionꢀbyꢀ±ꢀ200ꢀmVꢀfromꢀVo h (min.)ꢀorꢀVo l ꢀ(max.)ꢀ
when the output is in the high impedance state.
6. If clock rising time is longer than 1ns, tr/2ꢀ-ꢀ0.5nsꢀshouldꢀbeꢀaddedꢀtoꢀtheꢀparameter.
Integrated Silicon Solution, Inc. — www.issi.comꢀ
13
Rev. C
08/07/09
IS42S16400E
OPERATING FREQUENCY / LATENCY RELATIONSHIPS
SYMBOL PARAMETER
-6
-7
UNITS
ꢀ
ꢀ
—ꢀ
ꢀ
ClockꢀCycleꢀTimeꢀ
ꢀ
ꢀ
ꢀ
CLꢀ=ꢀ3ꢀ
CLꢀ=ꢀ2ꢀ
6ꢀ
7.5ꢀ
7ꢀ
7.5ꢀ
nsꢀꢀ
ns
ꢀ
ꢀ
—ꢀ
ꢀ
OperatingꢀFrequencyꢀ
ꢀ
ꢀ
ꢀ
CLꢀ=ꢀ3ꢀ
CLꢀ=ꢀ2ꢀ
166ꢀ
133ꢀ
143ꢀ
133ꢀ
MHzꢀ
MHz
tc c D ꢀ
tc k e D ꢀ
tp e D ꢀ
tD q D ꢀ
tD q m ꢀ
tD q z ꢀ
tD w D ꢀ
READ/WRITEꢀcommandꢀtoꢀREAD/WRITEꢀcommandꢀ
CKEꢀtoꢀclockꢀdisableꢀorꢀpower-downꢀentryꢀmodeꢀ
CKEꢀtoꢀclockꢀenableꢀorꢀpower-downꢀexitꢀsetupꢀmodeꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
1ꢀ
1ꢀ
1ꢀ
0ꢀ
0ꢀ
2ꢀ
0ꢀ
1ꢀ
1ꢀ
1ꢀ
0ꢀ
0ꢀ
2ꢀ
0ꢀ
cycle
cycle
cycle
cycle
cycle
cycle
cycle
DQMꢀtoꢀinputꢀdataꢀdelayꢀ
ꢀ
ꢀ
DQMꢀtoꢀdataꢀmaskꢀduringꢀWRITEsꢀ
DQMꢀtoꢀdataꢀhigh-impedanceꢀduringꢀREADsꢀ ꢀ
WRITEꢀcommandꢀtoꢀinputꢀdataꢀdelayꢀ
ꢀ
tD a l ꢀ
ꢀ
Data-inꢀtoꢀACTIVEꢀcommandꢀ
ꢀ
ꢀ
ꢀ
CLꢀ=ꢀ3ꢀ
CLꢀ=ꢀ2ꢀ
5ꢀ
5ꢀ
5ꢀ
5ꢀ
cycleꢀ
cycle
ꢀ
tD p l ꢀ
tb D l ꢀ
tc D l ꢀ
tr D l ꢀ
Data-inꢀtoꢀPRECHARGEꢀcommandꢀ
Lastꢀdata-inꢀtoꢀburstꢀSTOPꢀcommandꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
2ꢀ
1ꢀ
1ꢀ
2ꢀ
2ꢀ
2ꢀ
1ꢀ
1ꢀ
2ꢀ
2ꢀ
cycle
cycle
cycle
cycle
cycle
Lastꢀdata-inꢀtoꢀnewꢀREAD/WRITEꢀcommandꢀ ꢀ
Lastꢀdata-inꢀtoꢀPRECHARGEꢀcommandꢀ
ꢀ
ꢀ
tm r D ꢀ
ꢀ
LOADꢀMODEꢀREGISTERꢀcommandꢀ
toꢀACTIVEꢀorꢀREFRESHꢀcommand
ꢀ
ꢀ
tr o h ꢀ
ꢀ
Data-outꢀtoꢀhigh-impedanceꢀfromꢀ
PRECHARGEꢀcommandꢀ
ꢀ
ꢀ
CLꢀ=ꢀ3ꢀ
CLꢀ=ꢀ2ꢀ
3ꢀ
2ꢀ
3ꢀ
2ꢀ
cycle
cycle
AC TEST CONDITIONS (Input/OutputꢀReferenceꢀLevel:ꢀ1.4V)
Input Load
Output Load
tCK
tCHI
t
CL
3.0V
50 Ω
1.4V
0V
CLK
I/O
+1.4V
tCS
tCH
50 pF
3.0V
1.4V
INPUT
0V
tAC
t
OH
OUTPUT
1.4V
1.4V
14
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
TIVEꢀcommandꢀwhichꢀisꢀthenꢀfollowedꢀbyꢀaꢀREADꢀorWRITEꢀ
IS42S16400E
FUNCTIONAL DESCRIPTION
Initialization
Theꢀ64MbꢀSDRAMsꢀ(1ꢀMegꢀxꢀ16ꢀxꢀ4ꢀbanks)ꢀareꢀquad-bankꢀ
DRAMsꢀwhichꢀoperateꢀatꢀ3.3Vꢀandꢀincludeꢀaꢀsynchronousꢀ
interface (all signals are registered on the positive edge of
theꢀclockꢀsignal,ꢀCLK).ꢀEachꢀofꢀtheꢀ16,777,216-bitꢀbanksꢀisꢀ
organizedꢀasꢀ4,096ꢀrowsꢀbyꢀ256ꢀcolumnsꢀbyꢀ16ꢀbits.
SDRAMsꢀ mustꢀ beꢀ poweredꢀ upꢀ andꢀ initializedꢀ inꢀ aꢀ
predefined manner.
Theꢀ64MꢀSDRAMꢀisꢀinitializedꢀafterꢀtheꢀpowerꢀisꢀappliedꢀ
toꢀVD D ꢀandꢀVD D q ꢀ(simultaneously),ꢀandꢀtheꢀclockꢀisꢀstableꢀ
withꢀDQMꢀHighꢀandꢀCKEꢀHigh.ꢀ
ReadꢀandꢀwriteꢀaccessesꢀtoꢀtheꢀSDRAMꢀareꢀburstꢀoriented;ꢀ
accesses start at a selected location and continue for
a programmed number of locations in a programmed
sequence.ꢀAccessesꢀbeginꢀwithꢀtheꢀregistrationꢀofꢀanꢀAC-
Aꢀ100µsꢀdelayꢀisꢀrequiredꢀpriorꢀtoꢀissuingꢀanyꢀcommandꢀ
other than a COMMANDꢀINHIBIT or a NOP.ꢀTheꢀCOMMANDꢀ
INHIBITꢀorꢀNOPꢀmayꢀbeꢀappliedꢀduringꢀtheꢀ100µsꢀperiodꢀandꢀ
continue should at least through the end of the period.
WithꢀatꢀleastꢀoneꢀCOMMANDꢀINHIBITꢀorꢀNOPꢀcommandꢀ
havingꢀbeenꢀapplied,ꢀaꢀPRECHARGEꢀcommandꢀshouldꢀ
beꢀappliedꢀonceꢀtheꢀ100µsꢀdelayꢀhasꢀbeenꢀsatisfied.ꢀꢀAllꢀ
banksꢀmustꢀbeꢀprecharged.ꢀꢀThisꢀwillꢀleaveꢀallꢀbanksꢀinꢀ
an idle state, afterꢀwhichꢀatꢀleastꢀtwoꢀAUTOꢀREFRESH cycles
must be performed. After the AUTOꢀREFRESH cycles are
complete,ꢀ theꢀ SDRAMꢀ isꢀ thenꢀ readyꢀ forꢀ modeꢀ registerꢀ
programming.
command.ꢀTheꢀaddressꢀbitsꢀregisteredꢀcoincidentꢀwithꢀtheꢀ
ACTIVEꢀcommandꢀareꢀusedꢀtoꢀselectꢀtheꢀbankꢀandꢀrowꢀtoꢀ
be accessed (BA0ꢀandꢀBA1ꢀselectꢀtheꢀbank,ꢀA0-A11ꢀselectꢀtheꢀ
row).Theꢀaddressꢀbitsꢀ(A0-A7) registeredcoincidentwiththe
READꢀorꢀWRITEꢀcommandꢀareꢀusedꢀtoꢀselectꢀtheꢀstartingꢀ
column location for the burst access.
Priorꢀ toꢀ normalꢀ operation,ꢀ theꢀ SDRAMꢀ mustꢀ beꢀ initial-
ized.ꢀTheꢀfollowingꢀsectionsꢀprovideꢀdetailedꢀinformationꢀ
coveringꢀdeviceꢀinitialization,ꢀregisterꢀdefinition,ꢀcommandꢀ
descriptions and device operation.
Theꢀ modeꢀ registerꢀ shouldꢀ beꢀ loadedꢀ priorꢀ toꢀ applyingꢀ
any operational command because it will power up in an
unknownꢀstate.ꢀAfterꢀtheꢀLoadꢀModeꢀRegisterꢀcommand,ꢀ
atꢀleastꢀoneꢀNOPꢀcommandꢀmustꢀbeꢀassertedꢀpriorꢀtoꢀ
any command.
Integrated Silicon Solution, Inc. — www.issi.comꢀ
15
Rev. C
08/07/09
initiatingꢀtheꢀsubsequentꢀoperation.
Violatingꢀeitherꢀofꢀtheseꢀ
IS42S16400E
REGISTER DEFINITION
Mode Register
Theꢀmodeꢀregisterꢀisꢀusedꢀtoꢀdefineꢀtheꢀspecificꢀmodeꢀ
ofꢀoperationꢀofꢀtheꢀSDRAM.ꢀThisꢀdefinitionꢀincludesꢀtheꢀ
selection of a burst length, a burst type, a CAS latency,
an operating mode and a write burst mode, as shown in
MODEꢀREGISTERꢀDEFINITION.ꢀ
ModeꢀregisterꢀbitsꢀM0-M2ꢀspecifyꢀtheꢀburstꢀlength,ꢀM3ꢀ
specifiesthetypeofburst(sequentialꢀorꢀinterleaved),ꢀM4-ꢀM6ꢀ
specifyꢀtheꢀCASꢀlatency,ꢀM7ꢀandꢀM8ꢀspecifyꢀtheꢀoperatingꢀ
mode,ꢀM9ꢀspecifiesꢀtheꢀWRITEꢀburstꢀmode,ꢀandꢀM10ꢀandꢀ
M11ꢀareꢀreservedꢀforꢀfutureꢀuse.
Theꢀmodeꢀregisterꢀmustꢀbeꢀloadedꢀwhenꢀallꢀbanksꢀareꢀ
idle, and the controller must wait the specified time before
TheꢀmodeꢀregisterꢀisꢀprogrammedꢀviaꢀtheꢀLOADꢀMODEꢀ
REGISTERꢀcommandꢀandꢀwillꢀretainꢀtheꢀstoredꢀinformationꢀ
until it is programmed again or the device loses power.
requirementsꢀwillꢀresultꢀinꢀunspecifiedꢀoperation.
MODE REGISTER DEFINITION
Address Bus
A11 A10 A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Mode Register (Mx)
Reserved(1)
Burst Length
M2 M1 M0
M3=0
M3=1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1
2
4
8
1
2
4
8
Reserved Reserved
Reserved Reserved
Reserved Reserved
Full Page Reserved
Burst Type
M3
Type
0
1
Sequential
Interleaved
Latency Mode
M6 M5 M4
CAS Latency
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reserved
Reserved
2
3
Reserved
Reserved
Reserved
Reserved
Operating Mode
M8 M7 M6-M0 Mode
0
—
0
—
Defined Standard Operation
All Other States Reserved
—
Write Burst Mode
M9
0
Mode
Programmed Burst Length
Single Location Access
1. To ensure compatibility with future devices,
should program M11, M10 = "0, 0"
1
16
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
Burst Length
ing that the burst will wrap within the block if a boundary
isꢀreached.ꢀTheꢀblockꢀisꢀuniquelyꢀselectedꢀbyꢀA1-A7ꢀ(x16)ꢀ
whenꢀtheꢀburstꢀlengthꢀisꢀsetꢀtoꢀtwo;ꢀbyꢀA2-A7ꢀ(x16)ꢀwhenꢀ
theꢀburstꢀlengthꢀisꢀsetꢀtoꢀfour;ꢀandꢀbyꢀA3-A7ꢀ(x16)ꢀwhenꢀtheꢀ
burstꢀlengthꢀisꢀsetꢀtoꢀeight.ꢀTheꢀremainingꢀ(leastꢀsignificant)ꢀ
addressꢀbit(s)ꢀisꢀ(are)ꢀusedꢀtoꢀselectꢀtheꢀstartingꢀlocationꢀ
withinꢀtheꢀblock.ꢀFull-pageꢀburstsꢀwrapꢀwithinꢀtheꢀpageꢀifꢀ
the boundary is reached.
ReadꢀandꢀwriteꢀaccessesꢀtoꢀtheꢀSDRAMꢀareꢀburstꢀoriented,ꢀ
with the burst length being programmable, as shown in
MODEꢀREGISTERꢀDEFINITION.ꢀTheꢀburstꢀlengthꢀdeter-
minesꢀtheꢀmaximumꢀnumberꢀofꢀcolumnꢀlocationsꢀthatꢀcanꢀ
beꢀaccessedꢀforꢀaꢀgivenꢀREADꢀorꢀWRITEꢀcommand.ꢀBurstꢀ
lengthsꢀofꢀ1,ꢀ2,ꢀ4ꢀorꢀ8ꢀlocationsꢀareꢀavailableꢀforꢀbothꢀtheꢀ
sequentialꢀandꢀtheꢀinterleavedꢀburstꢀtypes,ꢀandꢀaꢀfull-pageꢀ
burstꢀisꢀavailableꢀforꢀtheꢀsequentialꢀtype.ꢀTheꢀfull-pageꢀ
burstꢀisꢀusedꢀinꢀconjunctionꢀwithꢀtheꢀBURSTꢀTERMINATEꢀ
command to generate arbitrary burst lengths.
Burst Type
Accesses within a given burst may be programmed to be
eitherꢀsequentialꢀorꢀinterleaved;ꢀthisꢀisꢀreferredꢀtoꢀasꢀtheꢀ
burstꢀtypeꢀandꢀisꢀselectedꢀviaꢀbitꢀM3.
Reservedꢀstatesꢀshouldꢀnotꢀbeꢀused,ꢀasꢀunknownꢀoperationꢀ
or incompatibility with future versions may result.
WhenꢀaꢀREADꢀorꢀWRITEꢀcommandꢀisꢀissued,ꢀaꢀblockꢀofꢀ
columnsꢀequalꢀtoꢀtheꢀburstꢀlengthꢀisꢀeffectivelyꢀselected.ꢀAllꢀ
accesses for that burst take place within this block, mean-
Theꢀorderingꢀofꢀaccessesꢀwithinꢀaꢀburstꢀisꢀdeterminedꢀbyꢀ
the burst length, the burst type and the starting column
address,ꢀasꢀshownꢀinꢀBURSTꢀDEFINITIONꢀtable.
BURST DEFINITION
Burst
Starting Column
Address
Order of Accesses Within a Burst
Length
Type = Sequential
Type = Interleaved
A0
ꢀ
ꢀ
2ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
0ꢀ
1ꢀ
ꢀ
ꢀ
0-1ꢀ
1-0ꢀ
ꢀ
ꢀ
0-1
1-0
A1
0ꢀ
0ꢀ
1ꢀ
1ꢀ
A1
0ꢀ
0ꢀ
1ꢀ
ꢀ1ꢀ
0ꢀ
0ꢀ
1ꢀ
1ꢀ
A0
0ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
4ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
0-1-2-3ꢀ
1-2-3-0ꢀ
2-3-0-1ꢀ
3-0-1-2ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
0-1-2-3
1-0-3-2
2-3-0-1
3-2-1-0
1ꢀ
ꢀ
0ꢀ
ꢀ
ꢀ
1ꢀ
A2
0ꢀ
0ꢀ
0ꢀ
0ꢀ
1ꢀ
1ꢀ
1ꢀ
1ꢀ
A0
0ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
0-1-2-3-4-5-6-7ꢀ
1-2-3-4-5-6-7-0ꢀ
ꢀ2-3-4-5-6-7-0-1ꢀ
ꢀ3-4-5-6-7-0-1-2ꢀ
4-5-6-7-0-1-2-3ꢀ
5-6-7-0-1-2-3-4ꢀ
6-7-0-1-2-3-4-5ꢀ
7-0-1-2-3-4-5-6ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
0-1-2-3-4-5-6-7
ꢀ1-0-3-2-5-4-7-6
2-3-0-1-6-7-4-5
3-2-1-0-7-6-5-4
4-5-6-7-0-1-2-3
5-4-7-6-1-0-3-2
6-7-4-5-2-3-0-1
7-6-5-4-3-2-1-0
NotꢀSupportedꢀ
1ꢀ
ꢀ
ꢀ0ꢀ
1ꢀ
8ꢀ
ꢀ
0ꢀ
ꢀ
1ꢀ
ꢀ
0ꢀ
ꢀ
1ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Fullꢀ
Pageꢀ
(y)ꢀ
nꢀ=ꢀA0-A7ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Cn,ꢀCnꢀ+ꢀ1,ꢀCnꢀ+ꢀ2ꢀ
Cnꢀ+ꢀ3,ꢀCnꢀ+ꢀ4...
…Cnꢀ-ꢀ1,
ꢀ
(locationꢀ0-y)ꢀ
ꢀ
ꢀ
Cn…
Integrated Silicon Solution, Inc. — www.issi.com
17
Rev. C
08/07/09
IS42S16400E
Operating Mode
CAS Latency
TheꢀnormalꢀoperatingꢀmodeꢀisꢀselectedꢀbyꢀsettingꢀM7ꢀandꢀM8ꢀ
toꢀzero;ꢀtheꢀotherꢀcombinationsꢀofꢀvaluesꢀforꢀM7ꢀandꢀM8ꢀareꢀ
reservedꢀforꢀfutureꢀuseꢀand/orꢀtestꢀmodes.ꢀTheꢀprogrammedꢀ
burstꢀlengthꢀappliesꢀtoꢀbothꢀREADꢀandꢀWRITEꢀbursts.
TheꢀCASꢀlatencyꢀisꢀtheꢀdelay,ꢀinꢀclockꢀcycles,ꢀbetweenꢀ
the registrationꢀofꢀaꢀREADꢀcommandꢀandꢀtheꢀavailabilityꢀofꢀ
theꢀfirstꢀpieceꢀofꢀoutputꢀdata.ꢀTheꢀlatencyꢀcanꢀbeꢀsetꢀtoꢀtwoꢀorꢀ
three clocks.
Testꢀmodesꢀandꢀreservedꢀstatesꢀshouldꢀnotꢀbeꢀusedꢀbe-
cause unknown operation or incompatibility with future
versions may result.
IfꢀaꢀREADꢀcommandꢀisꢀregisteredꢀatꢀclockꢀedgeꢀn,ꢀandꢀ
the latency is m clocks, the data will be available by clock
edge n + m.ꢀTheꢀDQsꢀwillꢀstartꢀdrivingꢀasꢀaꢀresultꢀofꢀtheꢀ
clock edge one cycle earlier (n + m -ꢀ1),ꢀandꢀprovidedꢀthatꢀ
the relevant access times are met, the data will be valid by
clock edge n + m.ꢀForꢀexample,ꢀassumingꢀthatꢀtheꢀclockꢀ
cycle time is such that all relevant access times are met,
ifꢀaꢀREADꢀcommandꢀisꢀregisteredꢀatꢀT0ꢀandꢀtheꢀlatencyꢀ
isꢀprogrammedꢀtoꢀtwoꢀclocks,ꢀtheꢀDQsꢀwillꢀstartꢀdrivingꢀ
afterꢀT1ꢀandꢀtheꢀdataꢀwillꢀbeꢀvalidꢀbyꢀT2,ꢀasꢀshownꢀinꢀCASꢀ
Latencyꢀdiagrams.ꢀTheꢀAllowable Operating Frequency
tableꢀindicatesꢀtheꢀoperatingꢀfrequenciesꢀatꢀwhichꢀeachꢀ
CAS latency setting can be used.
Write Burst Mode
WhenꢀM9ꢀ=ꢀ0,ꢀtheꢀburstꢀlengthꢀprogrammedꢀviaꢀM0-M2ꢀ
appliesꢀtoꢀbothꢀREADꢀandꢀWRITEꢀbursts;ꢀwhenꢀM9ꢀ=ꢀ1,ꢀ
theꢀprogrammedꢀburstꢀlengthꢀappliesꢀtoꢀREADꢀbursts,ꢀbutꢀ
writeꢀaccessesꢀareꢀsingle-locationꢀ(nonburst)ꢀaccesses.
CAS Latency
Allowable Operating Frequency (MHz)
Reservedꢀstatesꢀshouldꢀnotꢀbeꢀusedꢀasꢀunknownꢀoperationꢀ
or incompatibility with future versions may result.
Speed
CAS Latency = 2
CAS Latency = 3
6
7
133
133
166
143
CAS Latency
T0
T1
T2
T3
CLK
READ
NOP
NOP
COMMAND
DQ
t
AC
D
OUT
OH
t
LZ
t
CAS Latency - 2
T0
T1
T2
T3
T4
CLK
READ
NOP
NOP
NOP
COMMAND
DQ
t
AC
D
OUT
OH
t
LZ
t
CAS Latency - 3
DON'T CARE
UNDEFINED
18
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
OPERATION
Activating Specific Row Within Specific Bank
BANK/ROW ACTIVATION
BeforeꢀanyꢀREADꢀorꢀWRITEꢀcommandsꢀcanꢀbeꢀissuedꢀ
toꢀaꢀbankꢀwithinꢀtheꢀSDRAM,ꢀaꢀrowꢀinꢀthatꢀbankꢀmustꢀbeꢀ
“opened.”ꢀThisꢀisꢀaccomplishedꢀviaꢀtheꢀACTIVEꢀcommand,ꢀ
which selects both the bank and the row to be activated
(see ActivatingꢀSpecificꢀRowꢀWithinꢀSpecificꢀBank).
CLK
HIGH - Z
CKE
CS
RAS
CAS
WE
After opening a row (issuingꢀanꢀACTIVEꢀcommand),ꢀaꢀREADꢀ
orꢀWRITEꢀcommandꢀmayꢀbeꢀissuedꢀtoꢀthatꢀrow,ꢀsubjectꢀtoꢀ
the tr c D ꢀspecification.ꢀMinimumꢀtr c D should be divided by
theꢀclockꢀperiodꢀandꢀroundedꢀupꢀtoꢀtheꢀnextꢀwholeꢀnumberꢀ
toꢀ determineꢀ theꢀ earliestꢀ clockꢀ edgeꢀ afterꢀ theꢀ ACTIVEꢀ
commandꢀonꢀwhichꢀaꢀREADꢀorꢀWRITEꢀcommandꢀcanꢀbeꢀ
entered.ꢀForꢀexample,ꢀaꢀtr c D specification of 20ns with a
125ꢀMHzꢀclockꢀ(8nsꢀperiod)ꢀresultsꢀinꢀ2.5ꢀclocks,ꢀroundedꢀ
toꢀ3.ꢀThisꢀisꢀreflectedꢀinꢀtheꢀfollowingꢀexample,ꢀwhichꢀcov-
ersꢀanyꢀcaseꢀwhereꢀ2ꢀ<ꢀ[tr c D ꢀ(MIN)/tc k ] ≤ꢀ3.ꢀ(Theꢀsameꢀ
procedure is used to convert other specification limits from
timeꢀunitsꢀtoꢀclockꢀcycles).
A0-A11
BA0, BA1
ROW ADDRESS
BANK ADDRESS
AꢀsubsequentꢀACTIVEꢀcommandꢀtoꢀaꢀdifferentꢀrowꢀinꢀtheꢀ
same bank can only be issued after the previous active
rowꢀhasꢀbeenꢀ“closed”ꢀ(precharged).ꢀTheꢀminimumꢀtimeꢀ
intervalꢀbetweenꢀsuccessiveꢀACTIVEꢀcommandsꢀtoꢀtheꢀ
same bank is defined by tr c .
AꢀsubsequentꢀACTIVEꢀcommandꢀtoꢀanotherꢀbankꢀcanꢀbeꢀ
issuedwhilethefirstbankisbeingaccessed, whichresults
inꢀaꢀreductionꢀofꢀtotalꢀrow-accessꢀoverhead.ꢀTheꢀminimumꢀ
timeꢀintervalꢀbetweenꢀsuccessiveꢀACTIVEꢀcommandsꢀtoꢀ
different banks is defined by tr r D .
Example: Meeting tR C D (MIN) when 2 < [tR C D (min)/tC K ] ≤ 3
T0
T1
T2
T3
T4
CLK
READ or
WRITE
ACTIVE
NOP
NOP
COMMAND
t
RCD
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.com
19
Rev. C
08/07/09
sameꢀbank.TheꢀPRECHARGEꢀcommandꢀshouldꢀbeꢀissuedꢀ
IS42S16400E
READS
READ COMMAND
READꢀ burstsꢀ areꢀ initiatedꢀ withꢀ aꢀ READꢀ command,ꢀ asꢀ
shownꢀinꢀtheꢀREADꢀCOMMANDꢀdiagram.
CLK
Theꢀstartingꢀcolumnꢀandꢀbankꢀaddressesꢀareꢀprovidedꢀwithꢀ
theꢀREADꢀcommand,ꢀandꢀautoꢀprechargeꢀisꢀeitherꢀenabledꢀorꢀ
disabled for that burst access. If auto precharge is enabled,
the row being accessed is precharged at the completion of
theꢀburst.ꢀForꢀtheꢀgenericꢀREADꢀcommandsꢀusedꢀinꢀtheꢀfol-
lowing illustrations, auto precharge is disabled.
HIGH-Z
CKE
CS
RAS
DuringꢀREADꢀbursts,ꢀtheꢀvalidꢀdata-outꢀelementꢀfromꢀtheꢀ
starting column address will be available following the
CASꢀlatencyꢀafterꢀtheꢀREADꢀcommand.ꢀEachꢀsubsequentꢀ
data-outꢀelementꢀwillꢀbeꢀvalidꢀbyꢀtheꢀnextꢀpositiveꢀclockꢀ
edge.ꢀTheꢀCASꢀLatencyꢀdiagramꢀshowsꢀgeneralꢀtiming
for each possible CAS latency setting.
CAS
WE
COLUMN ADDRESS
AUTO PRECHARGE
Uponꢀcompletionꢀofꢀaꢀburst,ꢀassumingꢀnoꢀotherꢀcommandsꢀ
haveꢀbeenꢀinitiated,ꢀtheꢀDQsꢀwillꢀgoꢀHigh-Z.ꢀAꢀfull-pageꢀburstꢀ
will continue until terminated. (At the end of the page, it will
wrapꢀtoꢀcolumnꢀ0ꢀandꢀcontinue.)
A0-A7
A8, A9, A11
A10
DataꢀfromꢀanyꢀREADꢀburstꢀmayꢀbeꢀtruncatedꢀwithꢀaꢀsub-
sequentꢀREADꢀcommand,ꢀandꢀdataꢀfromꢀaꢀfixed-lengthꢀ
READꢀburstꢀmayꢀbeꢀimmediatelyꢀfollowedꢀbyꢀdataꢀfromꢀaꢀ
READꢀcommand.ꢀInꢀeitherꢀcase,ꢀaꢀcontinuousꢀflowꢀofꢀdataꢀ
canꢀbeꢀmaintained.ꢀTheꢀfirstꢀdataꢀelementꢀfromꢀtheꢀnewꢀ
burst follows either the last element of a completed burst
or the last desired data element of a longer burst which
is being truncated.
NO PRECHARGE
BANK ADDRESS
BA0, BA1
TheꢀDQMꢀinputꢀisꢀusedꢀtoꢀavoidꢀI/Oꢀcontention,ꢀasꢀshownꢀ
inꢀFiguresꢀRW1ꢀandꢀRW2.ꢀTheꢀDQMꢀsignalꢀmustꢀbeꢀas-
sertedꢀ(HIGH)ꢀatꢀleastꢀthreeꢀclocksꢀpriorꢀtoꢀtheꢀWRITEꢀ
commandꢀ(DQMꢀlatencyꢀisꢀtwoꢀclocksꢀforꢀoutputꢀbuffers)ꢀ
toꢀsuppressꢀdata-outꢀfromꢀtheꢀREAD.ꢀOnceꢀtheꢀWRITEꢀ
commandꢀisꢀregistered,ꢀtheꢀDQsꢀwillꢀgoꢀHigh-Zꢀ(orꢀremainꢀ
High-Z),ꢀregardlessꢀofꢀtheꢀstateꢀofꢀtheꢀDQMꢀsignal,ꢀprovidedꢀ
theꢀDQMꢀwasꢀactiveꢀonꢀtheꢀclockꢀjustꢀpriorꢀtoꢀtheꢀWRITEꢀ
commandꢀthatꢀtruncatedꢀtheꢀREADꢀcommand.ꢀIfꢀnot,ꢀtheꢀ
secondꢀWRITEꢀwillꢀbeꢀanꢀinvalidꢀWRITE.ꢀForꢀexample,ꢀifꢀ
DQMꢀwasꢀLOWꢀduringꢀT4ꢀinꢀFigureꢀRW2,ꢀthenꢀtheꢀWRITEsꢀ
atꢀT5ꢀandꢀT7ꢀwouldꢀbeꢀvalid,ꢀwhileꢀtheꢀWRITEꢀatꢀT6ꢀwouldꢀ
be invalid.
TheꢀnewꢀREADꢀcommandꢀshouldꢀbeꢀissuedꢀxcyclesbefore
the clock edge at which the last desired data element is
valid, where x equalsꢀtheꢀCASꢀlatencyꢀminusꢀone.ꢀThisꢀisꢀ
shownꢀinꢀConsecutiveꢀREADꢀBurstsꢀforꢀCASꢀlatenciesꢀofꢀ
twoꢀandꢀthree;ꢀdataꢀelementꢀn +ꢀ3ꢀisꢀeitherꢀtheꢀlastꢀofꢀaꢀ
burstꢀofꢀfourꢀorꢀtheꢀlastꢀdesiredꢀofꢀaꢀlongerꢀburst.ꢀTheꢀ64Mbꢀ
SDRAMꢀusesꢀaꢀpipelinedꢀarchitectureꢀandꢀthereforeꢀdoesꢀ
notꢀrequireꢀtheꢀ2n rule associated with a prefetch architec-
ture.ꢀAꢀREADꢀcommandꢀcanꢀbeꢀinitiatedꢀonꢀanyꢀclockꢀcycleꢀ
followingꢀaꢀpreviousꢀREADꢀcommand.ꢀFull-speedꢀrandomꢀ
read accesses can be performed to the same bank, as
shownꢀinꢀRandomꢀREADꢀAccesses,ꢀorꢀeachꢀsubsequentꢀ
READꢀmayꢀbeꢀperformedꢀtoꢀaꢀdifferentꢀbank.
TheꢀDQMꢀsignalꢀmustꢀbeꢀde-assertedꢀpriorꢀtoꢀtheꢀWRITEꢀ
commandꢀ(DQMꢀlatencyꢀisꢀzeroꢀclocksꢀforꢀinputꢀbuffers)ꢀ
to ensure that the written data is not masked.
DataꢀfromꢀanyꢀREADꢀburstꢀmayꢀbeꢀtruncatedꢀwithꢀaꢀsub-
sequentꢀWRITEꢀcommand,ꢀandꢀdataꢀfromꢀaꢀfixed-lengthꢀ
READꢀburstꢀmayꢀbeꢀimmediatelyꢀfollowedꢀbyꢀdataꢀfromꢀaꢀ
WRITEꢀcommandꢀ(subjectꢀtoꢀbusꢀturnaroundꢀlimitations).ꢀ
TheꢀWRITEꢀburstꢀmayꢀbeꢀinitiatedꢀonꢀtheꢀclockꢀedgeꢀim-
mediatelyꢀfollowingꢀtheꢀlastꢀ(orꢀlastꢀdesired)ꢀdataꢀelementꢀ
fromꢀtheꢀREADꢀburst,ꢀprovidedꢀthatꢀI/Oꢀcontentionꢀcanꢀbeꢀ
avoided. In a given system design, there may be a pos-
sibilityꢀthatꢀtheꢀdeviceꢀdrivingꢀtheꢀinputꢀdataꢀwillꢀgoꢀLow-Zꢀ
beforeꢀtheꢀSDRAMꢀDQsꢀgoꢀHigh-Z.ꢀInꢀthisꢀcase,ꢀatꢀleastꢀ
aꢀsingle-cycleꢀdelayꢀshouldꢀoccurꢀbetweenꢀtheꢀlastꢀreadꢀ
dataꢀandꢀtheꢀWRITEꢀcommand.
Aꢀfixed-lengthꢀREADꢀburstꢀmayꢀbeꢀfollowedꢀby,ꢀorꢀtruncatedꢀ
with, aPRECHARGE commandtothesamebank(provided
thatꢀautoꢀprechargeꢀwasꢀnotꢀactivated),ꢀandꢀaꢀfull-pageꢀburstꢀ
mayꢀbeꢀtruncatedꢀwithꢀaꢀPRECHARGEꢀcommandꢀtoꢀtheꢀ
x cycles before the clock edge at which the last desired
data element is valid, where x equalsꢀtheꢀCASꢀlatencyꢀ
minusꢀone.ꢀThisꢀisꢀshownꢀinꢀtheꢀREADꢀtoꢀPRECHARGEꢀ
20
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
providedꢀthatꢀautoꢀprechargeꢀwasꢀnotꢀactivated.TheꢀBURSTꢀ
IS42S16400E
diagramꢀforꢀeachꢀpossibleꢀCASꢀlatency;ꢀdataꢀelementꢀn +ꢀ
3ꢀisꢀeitherꢀtheꢀlastꢀofꢀaꢀburstꢀofꢀfourꢀorꢀtheꢀlastꢀdesiredꢀofꢀ
aꢀlongerꢀburst.ꢀFollowingꢀtheꢀPRECHARGEꢀcommand,ꢀaꢀ
subsequentꢀcommandꢀtoꢀtheꢀsameꢀbankꢀcannotꢀbeꢀissuedꢀ
until tr p is met. Note that part of the row precharge time is
hiddenꢀduringꢀtheꢀaccessꢀofꢀtheꢀlastꢀdataꢀelement(s).
Full-pageꢀREADꢀburstsꢀcanꢀbeꢀtruncatedꢀwithꢀtheꢀBURSTꢀ
TERMINATEꢀ command,ꢀ andꢀ fixed-lengthꢀ READꢀ burstsꢀ
mayꢀbeꢀtruncatedꢀwithꢀaꢀBURSTꢀTERMINATEꢀcommand,ꢀ
TERMINATEꢀcommandꢀshouldꢀbeꢀissuedꢀx cycles before
the clock edge at which the last desired data element is
valid, where x equalsꢀtheꢀCASꢀlatencyꢀminusꢀone.ꢀThisꢀisꢀ
shownꢀinꢀtheꢀREADꢀBurstꢀTerminationꢀdiagramꢀforꢀeachꢀ
possibleꢀCASꢀlatency;ꢀdataꢀelementꢀn+ꢀ3ꢀisꢀtheꢀlastꢀdesiredꢀ
data element of a longer burst.
Inꢀ theꢀ caseꢀ ofꢀ aꢀ fixed-lengthꢀ burstꢀ beingꢀ executedꢀ toꢀ
completion,ꢀ aꢀ PRECHARGEꢀ commandꢀ issuedꢀ atꢀ theꢀ
optimumꢀtimeꢀ(asꢀdescribedꢀabove)ꢀprovidesꢀtheꢀsameꢀ
operationꢀ thatꢀ wouldꢀ resultꢀ fromꢀ theꢀ sameꢀ fixed-lengthꢀ
burstꢀwithꢀautoꢀprecharge.ꢀTheꢀdisadvantageꢀofꢀtheꢀPRE-
CHARGEꢀcommandꢀisꢀthatꢀitꢀrequiresꢀthatꢀtheꢀcommandꢀ
and address buses be available at the appropriate time to
issueꢀtheꢀcommand;ꢀtheꢀadvantageꢀofꢀtheꢀPRECHARGEꢀ
commandꢀisꢀthatꢀitꢀcanꢀbeꢀusedꢀtoꢀtruncateꢀfixed-lengthꢀ
orꢀfull-pageꢀbursts.
CAS Latency
T0
T1
T2
T3
CLK
READ
NOP
NOP
COMMAND
DQ
t
AC
D
OUT
OH
t
LZ
t
CAS Latency - 2
T0
T1
T2
T3
T4
CLK
READ
NOP
NOP
NOP
COMMAND
DQ
tAC
D
OUT
OH
t
LZ
t
CAS Latency - 3
DON'T CARE
UNDEFINED
Integrated Silicon Solution, Inc. — www.issi.com
21
Rev. C
08/07/09
IS42S16400E
Consecutive READ Bursts
T0
T1
T2
T3
T4
T5
T6
CLK
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
READ
NOP
NOP
x=1 cycle
BANK,
COL n
BANK,
COL b
D
OUT
n
DOUT n+1
DOUT n+2
DOUT n+3
D
OUT
b
CAS Latency - 2
DON'T CARE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
COMMAND
READ
NOP
NOP
NOP
READ
NOP
x = 2 cycles
NOP
NOP
BANK,
COL n
BANK,
COL b
ADDRESS
DQ
DOUT
n
DOUT n+1
DOUT n+2
DOUT n+3
D
OUT
b
CAS Latency - 3
DON'T CARE
22
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
Random READ Accesses
T0
T1
T2
T3
T4
T5
CLK
COMMAND
ADDRESS
DQ
READ
READ
READ
READ
NOP
NOP
BANK,
COL n
BANK,
COL b
BANK,
COL m
BANK,
COL x
D
OUT
n
DOUT
b
DOUT
m
DOUT
x
CAS Latency - 2
DON'T CARE
T0
T1
T2
T3
T4
T5
T6
CLK
COMMAND
ADDRESS
DQ
READ
READ
READ
READ
NOP
NOP
NOP
BANK,
COL n
BANK,
COL b
BANK,
COL m
BANK,
COL x
DOUT
n
DOUT
b
DOUT
m
DOUT
x
CAS Latency - 3
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.comꢀ
23
Rev. C
08/07/09
IS42S16400E
RW1 - READ to WRITE
T0
T1
T2
T3
T4
T5
T6
CLK
DQM
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
NOP
NOP
WRITE
BANK,
COL n
BANK,
COL b
t
HZ
DOUT n+1
DOUT n+2
D
OUT
n
DIN b
CAS Latency - 2
t
DS
DON'T CARE
RW2 - READ to WRITE
T0
T1
T2
T3
T4
T5
CLK
DQM
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
NOP
WRITE
BANK,
COL n
BANK,
COL b
t
HZ
DOUT
n
DIN
b
CAS Latency - 3
t
DS
DON'T CARE
24
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
READ to PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
t
RP
PRECHARGE
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
NOP
NOP
ACTIVE
x = 1 cycle
BANK a,
COL n
BANK
BANK a,
ROW
(a or all)
D
OUT
n
DOUT n+1
DOUT n+2
DOUT n+3
CAS Latency - 2
DON'T CARE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
COMMAND
ADDRESS
DQ
t
RP
PRECHARGE
READ
NOP
NOP
NOP
NOP
x = 2 cycles
NOP
ACTIVE
BANK,
COL n
BANK,
COL b
BANK a,
ROW
DOUT
n
DOUT n+1
D
OUT n+2
DOUT n+3
CAS Latency - 3
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.comꢀ
25
Rev. C
08/07/09
IS42S16400E
READ Burst Termination
T0
T1
T2
T3
T4
T5
T6
CLK
BURST
TERMINATE
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
NOP
NOP
x = 1 cycle
BANK a,
COL n
D
OUT
n
DOUT n+1
DOUT n+2
DOUT n+3
CAS Latency - 2
DON'T CARE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
COMMAND
ADDRESS
DQ
BURST
TERMINATE
READ
NOP
NOP
NOP
NOP
x = 2 cycles
NOP
NOP
BANK,
COL n
DOUT
n
DOUT n+1
DOUT n+2
DOUT n+3
CAS Latency - 3
DON'T CARE
26
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
precharge.TheꢀdisadvantageꢀofꢀtheꢀPRECHARGEcommand
IS42S16400E
AnꢀexampleꢀisꢀshownꢀinꢀWRITEꢀtoꢀWRITEꢀdiagram.ꢀDataꢀ
n +ꢀ1ꢀisꢀeitherꢀtheꢀlastꢀofꢀaꢀburstꢀofꢀtwoꢀorꢀtheꢀlastꢀdesiredꢀ
ofꢀaꢀlongerꢀburst.ꢀTheꢀ64MbꢀSDRAMꢀ usesꢀ aꢀ pipelinedꢀ
architectureꢀandꢀthereforeꢀdoesꢀnotꢀrequireꢀtheꢀ2n rule as-
sociatedꢀwithꢀaꢀprefetchꢀarchitecture.ꢀAꢀWRITEꢀcommandꢀ
can be initiated on any clock cycle following a previous
WRITEꢀcommand.ꢀFull-speedꢀrandomꢀwriteꢀaccessesꢀwithinꢀ
a page can be performed to the same bank, as shown in
RandomꢀWRITEꢀCycles,ꢀorꢀeachꢀsubsequentꢀWRITEꢀmayꢀ
be performed to a different bank.
WRITEs
WRITEꢀburstsꢀareꢀinitiatedꢀwithꢀaꢀWRITEꢀcommand,ꢀasꢀ
shownꢀinꢀWRITEꢀCommandꢀdiagram.
WRITE Command
CLK
HIGH - Z
CKE
DataꢀforꢀanyꢀWRITEꢀburstꢀmayꢀbeꢀtruncatedꢀwithꢀaꢀsubse-
quentꢀREADꢀcommand,ꢀandꢀdataꢀforꢀaꢀfixed-lengthꢀWRITEꢀ
burstꢀmayꢀbeꢀimmediatelyꢀfollowedꢀbyꢀaꢀsubsequentꢀREADꢀ
command.ꢀOnceꢀtheꢀREADꢀcommandꢀisꢀregistered,ꢀtheꢀ
dataꢀinputsꢀwillꢀbeꢀignored,ꢀandꢀWRITEsꢀwillꢀnotꢀbeꢀex-
ecuted.ꢀAnꢀexampleꢀisꢀshownꢀinꢀWRITEꢀtoꢀREAD.ꢀDataꢀn
+ꢀ1ꢀisꢀeitherꢀtheꢀlastꢀofꢀaꢀburstꢀofꢀtwoꢀorꢀtheꢀlastꢀdesiredꢀ
of a longer burst.
CS
RAS
CAS
WE
Dataꢀ forꢀ aꢀ fixed-lengthꢀ WRITEꢀ burstꢀ mayꢀ beꢀ followedꢀ
by,ꢀorꢀtruncatedꢀwith,ꢀaꢀPRECHARGEꢀcommandꢀtoꢀtheꢀ
same bank (provided that auto precharge was not acti-
vated),ꢀandꢀaꢀfull-pageꢀWRITEꢀburstꢀmayꢀbeꢀtruncatedꢀ
withꢀaꢀPRECHARGEꢀcommandꢀtoꢀtheꢀsameꢀbank.ꢀTheꢀ
PRECHARGEꢀcommandꢀshouldꢀbeꢀissuedꢀtw r after the
clock edge at which the last desired input data element
isꢀregistered.ꢀTheꢀautoꢀprechargeꢀmodeꢀrequiresꢀaꢀtw r of
atꢀleastꢀoneꢀclockꢀplusꢀtime,ꢀregardlessꢀofꢀfrequency.ꢀInꢀ
addition,ꢀwhenꢀtruncatingꢀaꢀWRITEꢀburst,ꢀtheꢀDQMꢀsignalꢀ
must be used to mask input data for the clock edge prior
to,ꢀandꢀtheꢀclockꢀedgeꢀcoincidentꢀwith,ꢀtheꢀPRECHARGEꢀ
command.ꢀAnꢀexampleꢀisꢀshownꢀinꢀtheꢀWRITEꢀtoꢀPRE-
CHARGEꢀdiagram.ꢀDataꢀn+1ꢀisꢀeitherꢀtheꢀlastꢀofꢀaꢀburstꢀ
ofꢀtwoꢀorꢀtheꢀlastꢀdesiredꢀofꢀaꢀlongerꢀburst.ꢀFollowingꢀtheꢀ
PRECHARGEꢀcommand,ꢀaꢀsubsequentꢀcommandꢀtoꢀtheꢀ
same bank cannot be issued until tr p is met.
COLUMN ADDRESS
AUTO PRECHARGE
A0-A7
A8, A9, A11
A10
NO PRECHARGE
BANK ADDRESS
BA0, BA1
Theꢀstartingꢀcolumnꢀandꢀbankꢀaddressesꢀareꢀprovidedꢀwithꢀ
theꢀWRITEꢀcommand,ꢀandꢀautoꢀprechargeꢀisꢀeitherꢀenabledꢀ
or disabled for that access. If auto precharge is enabled,
the row being accessed is precharged at the completion of
theꢀburst.ꢀForꢀtheꢀgenericꢀWRITEꢀcommandsꢀusedꢀinꢀtheꢀ
following illustrations, auto precharge is disabled.
Inꢀtheꢀcaseꢀofꢀaꢀfixed-lengthꢀburstꢀbeingꢀexecutedꢀtoꢀcomple-
tion,ꢀaꢀPRECHARGEꢀcommandꢀissuedꢀatꢀtheꢀoptimumꢀ
time (asꢀdescribedꢀabove) provides the same operation that
wouldꢀresultꢀfromꢀtheꢀsameꢀfixed-lengthꢀburstꢀwithꢀautoꢀ
DuringꢀWRITEꢀbursts,ꢀtheꢀfirstꢀvalidꢀdata-in element will be
registeredcoincidentwiththeWRITEꢀcommand.ꢀSubsequentꢀ
data elements will be registered on each successive posi-
tiveꢀclockꢀedge.ꢀUponꢀcompletionꢀofꢀaꢀfixed-lengthꢀburst,ꢀ
assuming no other commands have been initiated, the
DQsꢀwillꢀremainꢀHigh-Zꢀandꢀanyꢀadditionalꢀinputꢀdataꢀwillꢀ
beꢀignoredꢀ(seeꢀWRITEꢀBurst).ꢀAꢀfull-pageꢀburstꢀwillꢀcon-
tinue until terminated. (At the end of the page, it will wrap
toꢀcolumnꢀ0ꢀandꢀcontinue.)
isꢀthatꢀitꢀrequiresꢀthatꢀtheꢀcommandꢀandꢀaddressꢀbusesꢀbeꢀ
availableꢀatꢀtheꢀappropriateꢀtimeꢀtoꢀissueꢀtheꢀcommand;ꢀtheꢀ
advantageꢀofꢀtheꢀPRECHARGEꢀcommandꢀisꢀthatꢀitꢀcanꢀbeꢀ
usedꢀtoꢀtruncateꢀfixed-lengthꢀorꢀfull-pageꢀbursts.
Fixed-lengthꢀorꢀfull-pageꢀWRITEꢀburstsꢀcanꢀbeꢀtruncatedꢀ
withꢀtheꢀBURSTꢀTERMINATEꢀcommand.ꢀWhenꢀtruncat-
ingꢀaꢀWRITEꢀburst,ꢀtheꢀinputꢀdataꢀappliedꢀcoincidentꢀwithꢀ
theꢀBURSTꢀTERMINATEꢀcommandꢀwillꢀbeꢀignored.ꢀTheꢀ
lastꢀdataꢀwrittenꢀ(providedꢀthatꢀDQMꢀisꢀLOWꢀatꢀthatꢀtime)ꢀ
will be the input data applied one clock previous to the
BURSTꢀTERMINATEꢀcommand.ꢀThisꢀisꢀshownꢀinꢀWRITEꢀ
BurstꢀTermination,ꢀwhereꢀdataꢀn is the last desired data
element of a longer burst.
DataꢀforꢀanyꢀWRITEꢀburstꢀmayꢀbeꢀtruncatedꢀwithꢀaꢀsubse-
quentꢀWRITEꢀcommand,ꢀandꢀdataꢀforꢀaꢀfixed-lengthꢀWRITEꢀ
burstꢀmayꢀbeꢀimmediatelyꢀfollowedꢀbyꢀdataꢀforꢀaꢀWRITEꢀ
command.ꢀTheꢀnewꢀWRITEꢀcommandꢀcanꢀbeꢀissuedꢀonꢀ
anyꢀclockꢀfollowingꢀtheꢀpreviousꢀWRITEꢀcommand,ꢀandꢀtheꢀ
data provided coincident with the new command applies to
the new command.
Integrated Silicon Solution, Inc. — www.issi.com
27
Rev. C
08/07/09
IS42S16400E
WRITE Burst
T0
T1
T2
T3
CLK
COMMAND
ADDRESS
DQ
WRITE
NOP
NOP
NOP
BANK,
COL n
DIN
n
DIN n+1
DON'T CARE
WRITE to WRITE
T0
T1
T2
CLK
COMMAND
ADDRESS
DQ
WRITE
NOP
WRITE
BANK,
COL n
BANK,
COL b
DIN
n
DIN n+1
DIN b
DON'T CARE
Random WRITE Cycles
T0
T1
T2
T3
CLK
COMMAND
ADDRESS
DQ
WRITE
WRITE
WRITE
WRITE
BANK,
COL n
BANK,
COL b
BANK,
COL m
BANK,
COL x
DIN
n
DIN
b
DIN
m
DIN x
28
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
WRITE to READ
T0
T1
T2
T3
T4
T5
CLK
COMMAND
ADDRESS
DQ
WRITE
NOP
READ
NOP
NOP
NOP
BANK,
COL n
BANK,
COL b
DIN
n
DIN n+1
D
OUT
b
DOUT b+1
CAS Latency - 2
DON'T CARE
WP1 - WRITE to PRECHARGE
T0
T1
T2
T3
T4
T5
T6
CLK
DQM
t
RP
PRECHARGE
COMMAND
ADDRESS
DQ
WRITE
NOP
NOP
ACTIVE
NOP
NOP
BANK a,
COL n
BANK
BANK a,
ROW
(a or all)
t
WR
DIN
n
DIN n+1
CAS Latency - 2
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.com
29
Rev. C
08/07/09
IS42S16400E
WP2 - WRITE to PRECHARGE
T0
T1
T2
T3
T4
T5
T6
CLK
DQM
tRP
PRECHARGE
COMMAND
ADDRESS
DQ
WRITE
NOP
NOP
NOP
ACTIVE
NOP
BANK a,
COL n
BANK
BANK a,
ROW
(a or all)
t
WR
DIN
n
D
IN n+1
CAS Latency - 3
DON'T CARE
WRITE Burst Termination
T0
T1
T2
CLK
BURST
TERMINATE
NEXT
COMMAND
ADDRESS
DQ
WRITE
COMMAND
BANK,
COL n
(ADDRESS)
DIN
n
(DATA)
DON'T CARE
30
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
allꢀbanks.Theꢀbank(s)ꢀwillꢀbeꢀavailableꢀforꢀaꢀsubsequentꢀrowꢀ
IS42S16400E
PRECHARGE
PRECHARGE Command
TheꢀPRECHARGEꢀcommandꢀ(seeꢀfigure)ꢀisꢀusedꢀtoꢀdeac-
tivate the open row in a particular bank or the open row in
CLK
HIGH - Z
access some specified time (tr p )ꢀafterꢀtheꢀPRECHARGEꢀ
command is issued.Input A10 determines whether one or
all banks are to be precharged, and in the case where only
oneꢀbankꢀisꢀtoꢀbeꢀprecharged,ꢀinputsꢀBA0,ꢀBA1ꢀselectꢀtheꢀ
bank.ꢀWhenꢀallꢀbanksꢀareꢀtoꢀbeꢀprecharged,ꢀinputsꢀBA0,ꢀ
BA1ꢀareꢀtreatedꢀasꢀ“Don’tꢀCare.”ꢀOnceꢀaꢀbankꢀhasꢀbeenꢀ
precharged, it is in the idle state and must be activated
priorꢀtoꢀanyꢀREADꢀorꢀWRITEꢀcommandsꢀbeingꢀissuedꢀtoꢀ
that bank.
CKE
CS
RAS
CAS
WE
POWER-DOWN
A0-A9, A11
ALL BANKS
Power-downꢀoccursꢀifꢀCKEꢀisꢀregisteredꢀLOWꢀcoincidentꢀ
withꢀaꢀNOPꢀorꢀCOMMANDꢀINHIBITꢀwhenꢀnoꢀaccessesꢀ
areꢀinꢀprogress.ꢀIfꢀpower-downꢀoccursꢀwhenꢀallꢀbanksꢀareꢀ
idle,ꢀthisꢀmodeꢀisꢀreferredꢀtoꢀasꢀprechargeꢀpower-down;ꢀ
ifꢀpower-downꢀoccursꢀwhenꢀthereꢀisꢀaꢀrowꢀactiveꢀinꢀeitherꢀ
bank,ꢀ thisꢀ modeꢀ isꢀ referredꢀ toꢀ asꢀ activeꢀ power-down.ꢀ
Enteringꢀ power-downꢀ deactivatesꢀ theꢀ inputꢀ andꢀ outputꢀ
buffers,ꢀexcludingꢀCKE,ꢀforꢀmaximumꢀpowerꢀsavingsꢀwhileꢀ
inꢀstandby.ꢀTheꢀdeviceꢀmayꢀnotꢀremainꢀinꢀtheꢀpower-downꢀ
stateꢀlongerꢀthanꢀtheꢀrefreshꢀperiodꢀ(64ms)ꢀsinceꢀnoꢀrefreshꢀ
operations are performed in this mode.
A10
BANK SELECT
BANK ADDRESS
BA0, BA1
Theꢀpower-downꢀstateꢀisꢀexitedꢀbyꢀregisteringꢀaꢀNOPꢀorꢀ
COMMANDꢀINHIBITꢀandꢀCKEꢀHIGHꢀatꢀtheꢀdesiredꢀclockꢀ
edge (meeting tc k s ).ꢀSeeꢀfigureꢀbelow.
POWER-DOWN
CLK
t
CKS
≥ tCKS
CKE
COMMAND
NOP
NOP
ACTIVE
tRCD
tRAS
t
RC
All banks idle
Input buffers gated off
Enter power-down mode
Exit power-down mode
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.comꢀ
31
Rev. C
08/07/09
IS42S16400E
CLOCK SUSPEND
ofꢀaꢀsuspendedꢀinternalꢀclockꢀedgeꢀisꢀignored;ꢀanyꢀdataꢀ
presentꢀonꢀtheꢀDQꢀpinsꢀremainsꢀdriven;ꢀandꢀburstꢀcountersꢀ
are not incremented, as long as the clock is suspended.
(Seeꢀfollowingꢀexamples.)
Clock suspend mode occurs when a column access/burst
isꢀinꢀprogressꢀandꢀCKEꢀisꢀregisteredꢀLOW.ꢀInꢀtheꢀclockꢀ
suspendꢀmode,ꢀtheꢀinternalꢀclockꢀisꢀdeactivated,ꢀ“freezing”ꢀ
the synchronous logic.
ClockꢀsuspendꢀmodeꢀisꢀexitedꢀbyꢀregisteringꢀCKEꢀHIGH;ꢀ
the internal clock and related operation will resume on the
subsequentꢀpositiveꢀclockꢀedge.
ForꢀeachꢀpositiveꢀclockꢀedgeꢀonꢀwhichꢀCKEꢀisꢀsampledꢀ
LOW,ꢀtheꢀnextꢀinternalꢀpositiveꢀclockꢀedgeꢀisꢀsuspended.ꢀ
Any command or data present on the input pins at the time
Clock Suspend During WRITE Burst
T0
T1
T2
T3
T4
T5
CLK
CKE
INTERNAL
CLOCK
COMMAND
ADDRESS
DQ
NOP
WRITE
NOP
NOP
BANK a,
COL n
DIN
n
DIN n+1
DIN n+2
DON'T CARE
Clock Suspend During READ Burst
T0
T1
T2
T3
T4
T5
T6
CLK
CKE
INTERNAL
CLOCK
COMMAND
ADDRESS
DQ
READ
NOP
NOP
NOP
NOP
NOP
BANK a,
COL n
DOUT
n
D
OUT n+1
DOUT n+2
DOUT n+3
DON'T CARE
32
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
BURST READ/SINGLE WRITE
Theꢀburstꢀread/singleꢀwriteꢀmodeꢀisꢀenteredꢀbyꢀprogrammingꢀ
the write burst mode bit (M9) in the mode register to a logic
1. In this mode, all WRITE commands result in the access
ofꢀaꢀsingleꢀcolumnꢀlocationꢀ(burstꢀofꢀone),ꢀregardlessꢀofꢀ
theꢀprogrammedꢀburstꢀlength.ꢀREADꢀcommandsꢀaccess
columns according to the programmed burst length and
sequence,ꢀjustꢀasꢀinꢀtheꢀnormalꢀmodeꢀofꢀoperationꢀ(M9ꢀ
=ꢀ0).
SDRAMsꢀsupportꢀCONCURRENTꢀAUTOꢀPRECHARGE.ꢀ
FourꢀcasesꢀwhereꢀCONCURRENTꢀAUTOꢀPRECHARGEꢀ
occurs are defined below.
READ with Auto Precharge
1.ꢀInterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge):ꢀ
AꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀaꢀREADꢀonꢀbankꢀn,ꢀ
CASꢀlatencyꢀlater.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀ
beginꢀwhenꢀtheꢀREADꢀtoꢀbankꢀmꢀisꢀregistered.
CONCURRENT AUTO PRECHARGE
2.ꢀInterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge):ꢀ
AꢀWRITEꢀtoꢀbankꢀmꢀwillꢀinterruptꢀaꢀREADꢀonꢀbankꢀnꢀ
whenꢀregistered.ꢀDQMꢀshouldꢀbeꢀusedꢀtwoꢀclocksꢀpriorꢀ
toꢀtheꢀWRITEꢀcommandꢀtoꢀpreventꢀbusꢀcontention.ꢀTheꢀ
PRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀwhenꢀtheꢀWRITEꢀtoꢀ
bank m is registered.
Anꢀaccessꢀcommandꢀ(READꢀorꢀWRITE)ꢀtoꢀanotherꢀbankꢀ
while an access command with auto precharge enabled is
executingꢀisꢀnotꢀallowedꢀbyꢀSDRAMs,ꢀunlessꢀtheꢀSDRAMꢀ
supportsꢀ CONCURRENTꢀ AUTOꢀ PRECHARGE.ꢀ ISSI
Fig CAP 1 - READ With Auto Precharge interrupted by a READ
T0
T1
T2
T3
T4
T5
T6
T7
CLK
READ - AP
BANK n
READ - AP
BANK m
NOP
NOP
NOP
NOP
NOP
NOP
Idle
COMMAND
BANK n
Page Active
READ with Burst of 4
Page Active
Interrupt Burst, Precharge
t
RP - BANK n
tRP - BANK m
Internal States
BANK m
READ with Burst of 4
Precharge
BANK n,
COL a
BANK m,
COL b
ADDRESS
DQ
D
OUT
a
DOUT a+1
DOUT
b
DOUT b+1
CAS Latency - 3 (BANK n)
CAS Latency - 3 (BANK m)
DON'T CARE
Fig CAP 2 - READ With Auto Precharge interrupted by a WRITE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
WRITE - AP
BANK n
WRITE - AP
BANK m
COMMAND
NOP
NOP
NOP
NOP
NOP
NOP
Idle
BANK n
READ with Burst of 4
Page Active
Interrupt Burst, Precharge
Page Active
tRP - BANK n
tRP - BANK m
Internal States
BANK m
WRITE with Burst of 4
Write-Back
BANK n,
COL a
BANK m,
COL b
ADDRESS
DQM
DQ
D
OUT
a
DIN
b
DIN b+1
DIN b+2
DIN b+3
CAS Latency - 3 (BANK n)
DON'T CARE
Integrated Silicon Solution, Inc. — www.issi.comꢀ
33
Rev. C
08/07/09
IS42S16400E
WRITE with Auto Precharge
4.ꢀInterruptedꢀbyꢀaꢀWRITEꢀ(withꢀorꢀwithoutꢀautoꢀprecharge):ꢀ
WRITE tobankmwillinterruptaWRITE onbanknwhen
3.ꢀInterruptedꢀbyꢀaꢀREADꢀ(withꢀorꢀwithoutꢀautoꢀprecharge):ꢀ
AꢀREADꢀtoꢀbankꢀmꢀwillꢀinterruptꢀaꢀWRITEꢀonꢀbankꢀnꢀ
whenꢀregistered,ꢀwithꢀtheꢀdata-outꢀappearingꢀCASlatency
later.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀafterꢀtw r
is met, where tw r ꢀbeginsꢀwhenꢀtheꢀREADꢀtoꢀbankꢀmꢀisꢀ
registered.ꢀTheꢀlastꢀvalidꢀWRITEꢀtoꢀbankꢀnꢀwillꢀbeꢀdata-inꢀ
registeredꢀoneꢀclockꢀpriorꢀtoꢀtheꢀREADꢀtoꢀbankꢀm.
A
registered.ꢀTheꢀPRECHARGEꢀtoꢀbankꢀnꢀwillꢀbeginꢀafterꢀ
tw r is met, where tw r ꢀbeginsꢀwhenꢀtheꢀWRITEꢀtoꢀbankꢀ
mꢀisꢀregistered.ꢀTheꢀlastꢀvalidꢀdataꢀWRITEꢀtoꢀbankꢀnꢀ
willꢀbeꢀdataꢀregisteredꢀoneꢀclockꢀpriorꢀtoꢀaꢀWRITEꢀtoꢀ
bank m.
Fig CAP 3 - WRITE With Auto Precharge interrupted by a READ
T0
T1
T2
T3
T4
T5
T6
T7
CLK
COMMAND
BANK n
WRITE - AP
BANK n
READ - AP
BANK m
NOP
NOP
NOP
NOP
NOP
NOP
Page Active
WRITE with Burst of 4 Interrupt Burst, Write-Back
WR - BANK n
Precharge
t
tRP - BANK n
Internal States
tRP - BANK m
BANK m
Page Active
READ with Burst of 4
Precharge
BANK n,
COL a
BANK m,
COL b
ADDRESS
DQ
DIN
a
DIN a+1
DOUT
b
DOUT b+1
CAS Latency - 3 (BANK m)
DON'T CARE
Fig CAP 4 - WRITE With Auto Precharge interrupted by a WRITE
T0
T1
T2
T3
T4
T5
T6
T7
CLK
COMMAND
BANK n
WRITE - AP
BANK n
WRITE - AP
BANK m
NOP
NOP
NOP
NOP
NOP
NOP
Page Active
WRITE with Burst of 4
Interrupt Burst, Write-Back
WR - BANK n
Precharge
t
t
RP - BANK n
Internal States
tRP - BANK m
BANK m
Page Active
WRITE with Burst of 4
Write-Back
BANK n,
COL a
BANK m,
COL b
ADDRESS
DQ
DIN
a
DIN a+1
DIN a+2
D
IN
b
DIN b+1
DIN b+2
DIN b+3
DON'T CARE
34
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
INITIALIꢀE AND LOAD MODE REGISTER(1)
T0
T1
Tn+1
To+1
t
CL
Tp+1
Tp+2
Tp+3
tCK
t
CH
CLK
CKE
tCKS t
CKH
t
CMH
tCMS
t
CMH
tCMS
tCMH tCMS
AUTO
REFRESH
AUTO
Load MODE
REGISTER
COMMAND
NOP
PRECHARGE
NOP
NOP
NOP
ACTIVE
REFRESH
DQM/
DQML, DQMH
t
t
AS
tAH
A0-A9, A11
A10
ROW
ROW
BANK
CODE
AS
tAH
ALL BANKS
CODE
SINGLE BANK
ALL BANKS
BA0, BA1
DQ
t
RP
t
RC
t
RC
tMRD
T
Power-up: VCC
Precharge AUTO REFRESH
AUTO REFRESH
Program MODE REGISTER(2, 3, 4)
and CLK stable all banks
At least 2 Auto-Refresh Commands
DON'T CARE
T = 100µs Min.
Notes:
1. If CSꢀisꢀHighꢀatꢀclockꢀHighꢀtime,ꢀallꢀcommandsꢀappliedꢀareꢀNOP.
2.ꢀꢀTheꢀModeꢀregisterꢀmayꢀbeꢀloadedꢀpriorꢀtoꢀtheꢀAuto-Refreshꢀcyclesꢀifꢀdesired.
3.ꢀꢀJEDECꢀandꢀPC100ꢀspecifyꢀthreeꢀclocks.
4.ꢀꢀOutputsꢀareꢀguaranteedꢀHigh-Zꢀafterꢀtheꢀcommandꢀisꢀissued.
Integrated Silicon Solution, Inc. — www.issi.comꢀ
35
Rev. C
08/07/09
IS42S16400E
POWER-DOWN MODE CYCLE
T0
T1
T2
Tn+1
Tn+2
tCK
t
CL
t
CH
CLK
t
CKS
t
CKH
t
CKS
tCKS
CKE
tCMS
tCMH
COMMAND
PRECHARGE
NOP
NOP
NOP
ACTIVE
DQM/
DQML, DQMH
A0-A9, A11
A10
ROW
ROW
ALL BANKS
SINGLE BANK
tAS
tAH
BA0, BA1
DQ
BANK
BANK
High-Z
Two clock cycles
Input buffers gated
All banks idle
off while in
power-down mode
Precharge all
active banks
All banks idle, enter
power-down mode
DON'T CARE
Exit power-down mode
CASꢀꢀlatencyꢀ=ꢀ2,ꢀ3
36
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
CLOCK SUSPEND MODE
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
t
CK
tCL
tCH
CLK
CKE
tCKS
t
CKH
t
CKS
t
CKH
t
CMS
tCMH
COMMAND
READ
NOP
NOP
NOP
NOP
NOP
WRITE
NOP
t
CMS tCMH
DQM/
DQML, DQMH
tAS
tAH
COLUMN n(2)
A0-A9, A11
A10
COLUMN m(2)
tAS
t
AH
tAS
t
AH
BA0, BA1
BANK
BANK
tDS
tDH
tAC
t
AC
tHZ
DQ
D
OUT
m
DOUT m+1
DOUT e
D
OUT e+1
tLZ
tOH
DON'T CARE
UNDEFINED
Notes:
1. CASꢀꢀlatencyꢀ=ꢀ3,ꢀburstꢀlengthꢀ=ꢀ2
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
37
Rev. C
08/07/09
IS42S16400E
AUTO-REFRESH CYCLE
T0
T1
T2
Tn+1
To+1
tCK
t
CL
t
CH
CLK
t
CKS CKH
t
CKE
t
CMS
tCMH
Auto
Refresh
Auto
COMMAND
PRECHARGE
NOP
NOP
NOP
ACTIVE
Refresh
DQM/
DQML, DQMH
A0-A9, A11
A10
ROW
ROW
BANK
ALL BANKS
SINGLE BANK
BANK(s)
BA0, BA1
DQ
tAS
tAH
High-Z
t
RP
t
RC
t
RC
DON'T CARE
CASꢀꢀlatencyꢀ=ꢀ2,ꢀ3
38
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
SELF-REFRESH CYCLE
T0
T1
T2
Tn+1
To+1
To+2
t
CK
tCH
t
CL
CLK
CKE
t
CKS
t
CKH
t
CKS
≥ tRAS
t
CKS
tCMS
tCMH
Auto
Auto
COMMAND
PRECHARGE
NOP
NOP
NOP
Refresh
Refresh
DQM/
DQML, DQMH
A0-A9, A11
A10
ALL BANKS
SINGLE BANK
t
AS
tAH
BA0, BA1
DQ
BANK
High-Z
tXSR
tRP
Precharge all
active banks
Enter self
refresh mode
CLK stable prior to exiting
Exit self refresh mode
(Restart refresh time base)
DON'T CARE
CASꢀꢀlatencyꢀ=ꢀ2,ꢀ3
Integrated Silicon Solution, Inc. — www.issi.comꢀ
39
Rev. C
08/07/09
IS42S16400E
READ WITHOUT AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
tCK
t
CL
tCH
CLK
CKE
tCKS tCKH
tCMS tCMH
COMMAND
ACTIVE
NOP
READ
NOP
NOP
NOP
PRECHARGE
ALL BANKS
NOP
ACTIVE
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
ROW
ROW
BANK
AS
t
AH
ROW
AS
t
AH
DISABLE AUTO PRECHARGE
SINGLE BANK
BANK
BA0, BA1
DQ
BANK
BANK
t
AC
t
AC
tAC
tAC
tHZ
DOUT
m
D
OUT m+1
D
OUT m+2
D
OUT m+3
t
LZ
tOH
tOH
tOH
tOH
tRCD
tRAS
t
RC
CAS Latency
DON'T CARE
t
RP
UNDEFINED
Notes:
1. CASꢀꢀlatencyꢀ=ꢀ2,ꢀburstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
40
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
READ WITH AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
tCK
tCL
tCH
CLK
CKE
t
CKS tCKH
tCMS tCMH
COMMAND
ACTIVE
NOP
READ
NOP
NOP
NOP
NOP
NOP
ACTIVE
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
ROW
ROW
BANK
AS
t
AH
ENABLE AUTO PRECHARGE
ROW
AS
t
AH
BA0, BA1
DQ
BANK
BANK
tAC
t
AC
t
AC
t
AC
tHZ
D
OUT
m
D
OUT m+1
D
OUT m+2
D
OUT m+3
t
LZ
t
OH
t
OH
tOH
tOH
tRCD
tRAS
t
RC
CAS Latency
DON'T CARE
tRP
UNDEFINED
Notes:
1. CASꢀꢀlatencyꢀ=ꢀ2,ꢀburstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
41
Rev. C
08/07/09
IS42S16400E
SINGLE READ WITHOUT AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
tCK
tCL
tCH
CLK
CKE
tCKS tCKH
tCMS tCMH
COMMAND
ACTIVE
NOP
READ
NOP
NOP
PRECHARGE
NOP
ACTIVE
NOP
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
ROW
ROW
BANK
AS
t
AH
ALL BANKS
ROW
SINGLE BANK
BANK
AS
t
AH
DISABLE AUTO PRECHARGE
BA0, BA1
DQ
BANK
BANK
t
OH
tAC
D
OUT m
t
LZ
tHZ
DON'T CARE
UNDEFINED
tRCD
tRAS
t
RC
CAS Latency
tRP
Notes:
1. CAS latency = 2, burst length = 1
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
42
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
SINGLE READ WITH AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
tCK
tCL
tCH
CLK
CKE
tCKS tCKH
tCMS
tCMH
COMMAND
ACTIVE
NOP
NOP
NOP
READ
NOP
NOP
ACTIVE
NOP
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
ROW
ROW
BANK
AS
t
AH
ENABLE AUTO PRECHARGE
ROW
AS
t
AH
BA0, BA1
BANK
BANK
tOH
tAC
DOUT m
DQ
t
HZ
DON'T CARE
UNDEFINED
tRCD
tRAS
t
RC
CAS Latency
tRP
Notes:
1. CAS latency = 2, burst length = 1
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
43
Rev. C
08/07/09
IS42S16400E
ALTERNATING BANK READ ACCESSES
T0
T1
T2
T3
T4
T5
T6
T7
T8
tCK
tCL
tCH
CLK
CKE
tCKS tCKH
tCMS tCMH
COMMAND
ACTIVE
NOP
READ
NOP
ACTIVE
NOP
READ
NOP
ACTIVE
tCMS tCMH
DQM/
DQML, DQMH
tAS tAH
COLUMN m(2)
ROW
ROW
COLUMN b(2)
ROW
ROW
A0-A9, A11
A10
ROW
tAS tAH
ENABLE AUTO PRECHARGE
ENABLE AUTO PRECHARGE
ROW
tAS tAH
BANK 0
BANK 3
BANK 3
BANK 0
BA0, BA1
BANK 0
t
LZ
t
OH
t
OH
tOH
tOH
t
OH
DQ
D
OUT
m
D
OUT m+
1
D
OUT m+
2
D
OUT m+
3
D
OUT
b
tAC
tAC
tAC
tAC
tAC
tAC
tRCD - BANK 0
tRRD
CAS Latency - BANK 0
tRP - BANK 0
tRCD - BANK 0
tRCD - BANK 3
CAS Latency - BANK 3
tRAS - BANK 0
tRC - BANK 0
DON'T CARE
Notes:
1. CASꢀꢀlatencyꢀ=ꢀ2,ꢀburstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
44
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
READ - FULL-PAGE BURST
T0
T1
T2
T3
T4
T5
T6
Tn+1
Tn+2
Tn+3
Tn+4
t
CK
tCL
tCH
CLK
CKE
tCKS tCKH
t
CMS
tCMH
COMMAND
ACTIVE
NOP
READ
CMS CMH
NOP
NOP
NOP
NOP
NOP
BURST TERM
NOP
NOP
t
t
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
AS
t
AH
ROW
AS
t
AH
BA0, BA1
BANK
BANK
tAC
tAC
tAC
tAC
tAC
tAC
tHZ
D
OUT
m
D
OUT m+
1
D
OUT m+
2
D
OUT m-
1
D
OUT
m
D
OUT m+1
DQ
t
LZ
t
OH
tOH
t
OH
tOH
t
OH
tOH
tRCD
CAS Latency
each row (x4) has
1,024 locations
DON'T CARE
UNDEFINED
Full page Full-page burst not self-terminating.
completion Use BURST TERMINATE command.
Notes:
1. CAS latency = 2, burst length = full page
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
45
Rev. C
08/07/09
IS42S16400E
READ - DQM OPERATION
T0
T1
T2
T3
T4
T5
T6
T7
T8
t
CK
t
CL
tCH
CLK
CKE
t
CKS tCKH
t
CMS tCMH
COMMAND
ACTIVE
NOP
READ
NOP
NOP
NOP
NOP
NOP
NOP
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
A0-A9, A11
A10
ROW
AS
tAH
ENABLE AUTO PRECHARGE
ROW
DISABLE AUTO PRECHARGE
AS
tAH
BA0, BA1
BANK
BANK
t
OH
tOH
tOH
t
AC
tAC
D
OUT
m
D
OUT m+
2
D
OUT m+
3
DQ
t
LZ
tLZ
t
HZ
tAC
t
HZ
DON'T CARE
UNDEFINED
t
RCD
CAS Latency
Notes:
1. CASꢀꢀlatencyꢀ=ꢀ2,ꢀburstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
46
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
WRITE - WITHOUT AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
t
CK
t
CL
tCH
CLK
CKE
t
CKS tCKH
t
CMS tCMH
COMMAND
ACTIVE
NOP
WRITE
NOP
NOP
NOP
PRECHARGE
NOP
ACTIVE
t
CMS tCMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
ROW
ROW
BANK
A0-A9, A11
A10
ROW
AS
t
AH
ALL BANKS
ROW
AS
t
AH
SINGLE BANK
BANK
DISABLE AUTO PRECHARGE
BANK
BA0, BA1
BANK
tDS
t
DH
t
DS
t
DH
t
DS
tDH
tDS
tDH
DQ
DIN
m
D
IN m+
1
D
IN m+
2
D
IN m+3
tRCD
tRAS
t
RC
t
WR(3)
t
RP
DON'T CARE
Notes:
1. burstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
3.ꢀtr a s must not be violated
Integrated Silicon Solution, Inc. — www.issi.comꢀ
47
Rev. C
08/07/09
IS42S16400E
WRITE - WITH AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
t
CK
tCL
tCH
CLK
CKE
t
CKS tCKH
t
CMS
tCMH
COMMAND
ACTIVE
NOP
WRITE
NOP
NOP
NOP
NOP
NOP
NOP
ACTIVE
t
CMS tCMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
ROW
ROW
BANK
A0-A9, A11
A10
ROW
AS
t
AH
ENABLE AUTO PRECHARGE
ROW
AS
t
AH
BA0, BA1
BANK
BANK
tDS
t
DH
t
DS
t
DH
t
DS
tDH
t
DS
tDH
DQ
DIN
m
D
IN m+
1
D
IN m+
2
D
IN m+3
tRCD
tRAS
t
RC
t
WR
tRP
DON'T CARE
Notes:
1. burstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
48
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
SINGLE WRITE - WITHOUT AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
t
CK
tCL
tCH
CLK
CKE
tCKS tCKH
t
CMS tCMH
NOP(4)
NOP(4)
PRECHARGE
NOP
ACTIVE
NOP
COMMAND
ACTIVE
NOP
WRITE
tCMS tCMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
ROW
A0-A9, A11
A10
ROW
AS
t
AH
ALL BANKS
ROW
ROW
SINGLE BANK
AS
t
AH
DISABLE AUTO PRECHARGE
BANK
BA0, BA1
BANK
BANK
BANK
t
DS
t
DH
DQ
DIN
m
t
t
t
RCD
RAS
RC
t
WR(3)
tRP
DON'T CARE
Notes:
1. burst length = 1
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
3.ꢀtr a s must not be violated
Integrated Silicon Solution, Inc. — www.issi.comꢀ
49
Rev. C
08/07/09
IS42S16400E
SINGLE WRITE - WITH AUTO PRECHARGE
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
t
CK
tCL
tCH
CLK
CKE
t
CKS tCKH
t
CMS tCMH
NOP(3)
NOP(3)
NOP(3)
WRITE
NOP
NOP
NOP
ACTIVE
NOP
COMMAND
ACTIVE
tCMS tCMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
ROW
ROW
BANK
A0-A9, A11
A10
ROW
AS
t
AH
ENABLE AUTO PRECHARGE
ROW
AS
t
AH
BA0, BA1
BANK
BANK
tDS
t
DH
DQ
DIN
m
tRCD
tRAS
t
RC
t
WR
tRP
DON'T CARE
Notes:
1. burst length = 1
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
50
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
ALTERNATING BANK WRITE ACCESS
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
tCK
tCL
tCH
CLK
CKE
t
CKS tCKH
tCMS
tCMH
COMMAND
ACTIVE
NOP
WRITE
NOP
ACTIVE
NOP
WRITE
NOP
NOP
ACTIVE
t
CMS tCMH
DQM/
DQML, DQMH
t
t
t
AS
tAH
COLUMN m(2)
ROW
ROW
COLUMN b(2)
ROW
ROW
A0-A9, A11
A10
ROW
AS
t
AH
ENABLE AUTO PRECHARGE
ENABLE AUTO PRECHARGE
ROW
AS
tAH
BANK 0
BANK 1
BANK 1
BANK 0
BA0, BA1
BANK 0
tDS
t
DH
t
DS
t
DH
tDS
t
DH
t
DS
t
DH
t
DS
t
DH
tDS
t
DH
tDS
tDH
t
DS
tDH
DQ
DIN
m
D
IN m+
1
D
IN m+
2
D
IN m+
3
D
IN
b
D
IN b+
1
D
IN b+
2
DIN b+3
t
t
t
t
RCD - BANK 0
RRD
t
WR - BANK 0
t
RP - BANK 0
t
RCD - BANK 0
t
RCD - BANK 1
tWR - BANK 1
RAS - BANK 0
RC - BANK 0
DON'T CARE
Notes:
1. burstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
51
Rev. C
08/07/09
IS42S16400E
WRITE - FULL PAGE BURST
T0
T1
T2
T3
T4
T5
Tn+1
Tn+2
t
CK
t
CL
tCH
CLK
CKE
t
CKS CKH
t
t
CMS
tCMH
COMMAND
ACTIVE
NOP
WRITE
NOP
NOP
NOP
NOP
BURST TERM
NOP
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
t
AH
COLUMN m(2)
A0-A9, A11
A10
ROW
AS
tAH
ROW
AS
tAH
BA0, BA1
BANK
BANK
t
DS
t
DH
t
DS
t
DH
tDS
t
DH
tDS
t
DH
t
DS
t
DH
t
DS
t
DH
D
IN
m
D
IN m+
1
D
IN m+
2
D
IN m+
3
DIN m-1
DQ
t
RCD
Full page completed
DON'T CARE
Notes:
1. burst length = full page
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
52
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
WRITE - DQM OPERATION
T0
T1
T2
T3
T4
T5
T6
T7
t
CK
t
CL
tCH
CLK
CKE
t
CKS CKH
t
tCMS
tCMH
COMMAND
ACTIVE
NOP
WRITE
NOP
NOP
NOP
NOP
NOP
t
CMS
t
CMH
DQM/
DQML, DQMH
t
t
t
AS
t
AH
COLUMN m(2)
A0-A9, A11
A10
ROW
AS
tAH
ENABLE AUTO PRECHARGE
ROW
DISABLE AUTO PRECHARGE
AS
tAH
BA0, BA1
BANK
BANK
t
DS
t
DH
t
DS
t
DH
t
DS
t
DH
D
IN
m
D
IN m+
2
DIN m+3
DQ
t
RCD
DON'T CARE
Notes:
1. burstꢀlengthꢀ=ꢀ4
2. A8, A9, and A11ꢀ=ꢀ"Don'tꢀCare"
Integrated Silicon Solution, Inc. — www.issi.comꢀ
53
Rev. C
08/07/09
IS42S16400E
ORDERING INFORMATION
Commercial Range: 0°C to +70°C
Frequency
ꢀ166ꢀMHzꢀ
ꢀ166ꢀMHzꢀ
ꢀ143ꢀMHzꢀ
ꢀ143ꢀMHzꢀ
Speed (ns)
Order Part No.
Package
6ꢀ
6ꢀ
7ꢀ
7ꢀ
IS42S16400E-6Tꢀ
IS42S16400E-6TLꢀ
IS42S16400E-7Tꢀ
IS42S16400E-7TLꢀ
400-milꢀTSOPꢀII
400-milꢀTSOPꢀII,ꢀLead-free
400-milꢀTSOPꢀII
400-milꢀTSOPꢀII,ꢀLead-freeꢀ
Industrial Range: -40°C to +85°C
Frequency
ꢀ166ꢀMHzꢀ
ꢀ143ꢀMHzꢀ
Speed (ns)
Order Part No.
Package
6ꢀ
7ꢀ
IS42S16400E-6TLIꢀ
IS42S16400E-7TLIꢀ
400-milꢀTSOPꢀII,ꢀLead-free
400-milꢀTSOPꢀII,ꢀLead-freeꢀ
54
www.issi.com — Integrated Silicon Solution, Inc.
Rev. C
08/07/09
IS42S16400E
Integrated Silicon Solution, Inc. — www.issi.comꢀ
55
Rev. C
08/07/09
相关型号:
IS42S16400F-5BLI
Synchronous DRAM, 4MX16, 5ns, CMOS, PBGA54, 8 X 8 MM, 0.80 MM PITCH, ROHS COMPLIANT, TFBGA-54
ISSI
©2020 ICPDF网 联系我们和版权申明