IS42VM32160C-10BI [ISSI]

512Mb Mobile Synchronous DRAM;
IS42VM32160C-10BI
型号: IS42VM32160C-10BI
厂家: INTEGRATED SILICON SOLUTION, INC    INTEGRATED SILICON SOLUTION, INC
描述:

512Mb Mobile Synchronous DRAM

动态存储器
文件: 总17页 (文件大小:358K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
IS42VM32160C  
16Mx32  
Preliminary Information  
JULY 2010  
512Mb Mobile Synchronous DRAM  
FEATURES:  
DESCRIPTION:  
ISSI's IS42VM32160C is a 512Mb Mobile Synchronous  
DRAM configured as a quad 4M x32 DRAM. It achieves  
high-speed data transfer using a pipeline architecture  
with a synchronous interface. All inputs and outputs sig-  
nals are registered on the rising edge of the clock input,  
CLK. The 512Mb SDRAM is internally configured by  
stacking two 256Mb, 16Mx16 devices. Each of the 4M  
x32ꢀbanksꢀisꢀorganizedꢀasꢀ8192ꢀrowsꢀbyꢀ512ꢀcolumnsꢀ  
by 32 bits.  
•ꢀ Fully synchronous; all signals referenced to a  
positive clock edge  
•ꢀ Internal bank for hiding row access and pre-  
charge  
•ꢀ Programmable CAS latency: 2, 3  
•ꢀ Programmable Burst Length: 1, 2, 4, 8, and Full  
Page  
•ꢀ Programmable Burst Sequence:  
•ꢀ Sequential and Interleave  
•ꢀ Auto Refresh (CBR)  
•ꢀ TCSR (Temperature Compensated Self Refresh)  
KEY TIMING PARAMETERS  
Parameter  
-10  
Unit  
•ꢀ PASR (Partial Arrays Self Refresh): 1/16, 1/8,  
1/4, 1/2, and Full  
•ꢀ Deep Power Down Mode (DPD)  
•ꢀ Driver Strength Control (DS): 1/4, 1/2, and Full  
CLK Cycle Time  
CAS Latency = 3  
CAS Latency = 2  
CLK Frequency  
CAS Latency = 3  
CAS Latency = 2  
Access Time from CLK  
CAS Latency = 3  
CAS Latency = 2  
10  
12  
ns  
ns  
OPTIONS:  
•ꢀ Configuration:ꢀ16Mx32  
•ꢀ PowerꢀSupply:  
Vd d /Vd d q = 1.8V  
•ꢀ Package:ꢀ90ꢀBallꢀBGAꢀ(8mmx13mm)  
•ꢀ TemperatureꢀRange:ꢀ  
Commercial (0oC to +70oC)  
Industrial (-40oC to +85oC)  
100  
83  
Mhz  
Mhz  
8.0  
ns  
ns  
9.0  
•ꢀ Dieꢀrevision:ꢀC  
ADDRESS TABLE  
Parameter  
16Mx32  
Configuration  
4M x 32 x 4 banks  
BA0, BA1  
A10/AP  
A0 – A12  
A0 – A8  
Bank Address Pins  
Autoprecharge Pins  
Row Addresses  
Column Addresses  
Refresh Count  
8K / 64ms  
Copyright © 2010 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without  
notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the lat-  
est version of this device specification before relying on any published information and before placing orders for products.  
Integrated Silicon Solution, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reason-  
ably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications  
unless Integrated Silicon Solution, Inc. receives written assurance to its satisfaction, that:  
a.) the risk of injury or damage has been minimized;  
b.) the user assume all such risks; and  
c.) potential liability of Integrated Silicon Solution, Inc is adequately protected under the circumstances  
Integrated Silicon Solution, Inc.  
1
Rev. 00B  
07/21/2010  
IS42VM32160C  
FUNCTIONAL BLOCK DIAGRAM (16Mx16)  
CLK  
CKE  
CS  
RAS  
CAS  
WE  
DQML  
DQMH  
DATA IN  
BUFFER  
COMMAND  
DECODER  
&
CLOCK  
GENERATOR  
16  
16  
REFRESH  
CONTROLLER  
MODE  
REGISTER  
2
DQ 0-15  
13  
V
V
DD/VDDQ  
ss/Vss  
SELF  
DATA OUT  
BUFFER  
REFRESH  
A10  
A12  
A11  
A9  
Q
CONTROLLER  
16  
16  
A8  
A7  
REFRESH  
COUNTER  
A6  
A5  
8192  
A4  
A3  
A2  
A1  
A0  
BA0  
BA1  
8192  
MEMORY CELL  
ARRAY  
8192  
8192  
13  
BANK 0  
ROW  
ADDRESS  
LATCH  
ROW  
ADDRESS  
BUFFER  
13  
13  
SENSEꢀAMPꢀI/OꢀGATE  
512  
(x 16)  
COLUMN  
ADDRESS LATCH  
BANK CONTROLꢀLOGIC  
9
BURST COUNTER  
COLUMN DECODER  
COLUMN  
ADDRESS BUFFER  
9
FUNCTIONAL BLOCK DIAGRAM (16Mx32)  
CS  
CLK  
CKE  
Die 01  
Die 02  
Command  
Addresses  
DQ0 –DQ31  
2
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
PIN DESCRIPTIONS  
Symbol  
CLK  
Type  
Input  
Description  
Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive edge of  
CLK. CLK also increments the internal burst counter and controls the output registers.  
CKE  
Input  
ClockꢀEnable:ꢀCKEꢀactivatesꢀ(HIGH)ꢀandꢀdeactivatesꢀ(LOW)ꢀtheꢀCLKꢀsignal.ꢀIfꢀCKEꢀgoesꢀlowꢀsynchronouslyꢀ  
with clock (set-up and hold time same as other inputs), the internal clock is suspended from the next clock  
cycle and the state of output and burst address is frozen as long as the CKE remains low. When all banks  
are in the idle state, deactivating the clock controls the entry to the Power Down and Self Refresh modes.  
CKE is synchronous except after the device enters Power Down and Self Refresh modes, where CKE  
becomes asynchronous until exiting the same mode.The input buffers, including CLK, are disabled during  
Power Down and Self Refresh modes, providing low standby power.  
BA0, BA1  
A0-A12  
Input  
Input  
Bank Select: BA0 and BA1 defines to which bank the BankActivate, Read, Write, or BankPrecharge  
command is being applied.  
Address Inputs:A0-A12 are sampled during the BankActivate command (row address A0-A12) and Read/  
Write command (column address A0-A8 with A10 defining Auto Precharge) to select one location in the  
respectivebank.DuringaPrechargecommand,A10issampledtodetermineifallbanksaretobeprecharged  
(A10ꢀ=HIGH).  
The address inputs also provide the op-code during a Mode Register Set .  
CS  
Input  
Input  
ChipSelect:CSenables(sampledLOW)anddisables(sampledHIGH)thecommanddecoder.Allcommandsꢀ  
are masked when CSꢀisꢀsampledꢀHIGH.ꢀCS provides for external bank selection on systems with multiple  
banks. It is considered part of the command code.  
RAS  
Row Address Strobe: The RAS signal defines the operation commands in conjunction with the CAS and  
WE signals and is latched at the positive edges of CLK. When RAS and CS are asserted “LOW” and CAS  
isꢀassertedꢀ“HIGH,eitherꢀtheꢀBankActivateꢀcommandꢀorꢀtheꢀPrechargeꢀcommandꢀisꢀselectedꢀbyꢀtheꢀWE  
signal. When the WEꢀisꢀassertedꢀ“HIGH,”ꢀtheꢀBankActivateꢀcommandꢀisꢀselectedꢀandꢀtheꢀbankꢀdesignatedꢀ  
by BA is turned on to the active state.When the WE is asserted “LOW,the Precharge command is selected  
and the bank designated by BA is switched to the idle state after the precharge operation.  
CAS  
Input  
Column Address Strobe: The CAS signal defines the operation commands in conjunction with the RAS  
and WE signals and is latched at the positive edges of CLK. When RASꢀisꢀheldꢀ“HIGH”ꢀandꢀCS is asserted  
“LOW,the column access is started by asserting CAS ”LOW.Then, the Read orWrite command is selected  
by asserting WEꢀ“LOW”ꢀorꢀ“HIGH.”  
WE  
Input  
Input  
Write Enable:The WE signal defines the operation commands in conjunction with the RAS and CAS signals  
and is latched at the positive edges of CLK.The WE input is used to select the BankActivate or Precharge  
command and Read or Write command.  
DQM0-3  
Data Input/Output Mask: DQM0-DQM3 are byte specific, nonpersistent I/O buffer controls. The I/O buffers  
areꢀplacedꢀinꢀaꢀhigh-zꢀstateꢀwhenꢀDQMꢀisꢀsampledꢀHIGH.ꢀInputꢀdataꢀisꢀmaskedꢀwhenꢀDQMꢀisꢀsampledꢀ  
HIGHꢀduringꢀaꢀwriteꢀcycle.ꢀOutputꢀdataꢀisꢀmaskedꢀ(two-clockꢀlatency)ꢀwhenꢀDQMꢀisꢀsampledꢀHIGHꢀduringꢀ  
a read cycle.DQM3 masks DQ31-DQ24, DQM2 masks DQ23-DQ16, DQM1 masks DQ15-DQ8, and DQM0  
masks DQ7-DQ0  
DQ0-31  
Input/ Data I/O: The DQ0-31 input and output data are synchronized with the positive edge of CLK. The I/Os are  
Output byte-maskable during Reads and Writes.  
Integrated Silicon Solution, Inc.  
3
Rev. 00B  
07/21/2010  
IS42VM32160C  
PIN CONFIGURATION  
PACKAGEꢀCODE:ꢀBꢀ90ꢀBALLꢀFBGAꢀ(TopꢀView)ꢀ(8.00ꢀmmꢀxꢀ13.00ꢀmmꢀBody,ꢀ0.8ꢀmꢀBallꢀPitch)  
1 2 3 4 5 6 7 8 9  
A
DQ26 DQ24 VSS  
DQ28 VDDQ VSSQ  
VSSQ DQ27 DQ25  
VSSQ DQ29 DQ30  
VDDQ DQ31 NC  
VSS DQM3 A3  
VDD DQ23 DQ21  
VDDQ VSSQ DQ19  
DQ22 DQ20 VDDQ  
DQ17 DQ18 VDDQ  
NC DQ16 VSSQ  
A2 DQM2 VDD  
B
C
D
E
F
G
H
J
A4  
A7  
A5  
A8  
A6  
A10  
NC  
A0  
A1  
A12  
BA1 A11  
CLK CKE A9  
DQM1 NC NC  
BA0  
CS RAS  
K
L
CAS WE DQM0  
VDD DQ7 VSSQ  
DQ6 DQ5 VDDQ  
DQ1 DQ3 VDDQ  
VDDQ VSSQ DQ4  
VDD DQ0 DQ2  
VDDQ DQ8 VSS  
VSSQ DQ10 DQ9  
VSSQ DQ12 DQ14  
DQ11 VDDQ VSSQ  
DQ13 DQ15 VSS  
M
N
P
R
PIN DESCRIPTIONS  
A0-A12  
A0-A8  
Row Address Input  
Column Address Input  
Bank Select Address  
WE  
Write Enable  
DQM0-DQM3 x32 Input/Output Mask  
BA0, BA1  
Vd d  
Vss  
Vd d q  
Vs s q  
NC  
Power  
DQ0 to DQ31 Data I/O  
Ground  
CLK  
CKE  
CS  
System Clock Input  
Power Supply for I/O Pin  
GroundꢀforꢀI/OꢀPin  
No Connect  
Clock Enable  
Chip Select  
RAS  
CAS  
Row Address Strobe Command  
Column Address Strobe Command  
4
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
Mobile SDRAM Functionality  
ISSI’s 512Mb Mobile SDRAMs are pin compatible and have similar functionality with ISSI’s standard SDRAMs, but  
offer lower operating voltages and power saving features. For detailed descriptions of pin functions, command truth  
tables, functional truth tables, device operation as well as timing diagrams please refer to ISSI document “Mobile  
Synchronous DRAM Device Operations & Timing Diagrams” listed at www.issi.com  
REGISTER DEFINITION  
Mode Register (MR) & Extended Mode Register (EMR)  
There are two mode registers in the Mobile SDRAM; Mode Register (MR) and Extended Mode Register (EMR). The  
Mode Register is discussed below, followed by the Extended Mode Register. The Mode Register is used to define  
the specific mode of operation of the SDRAM. This definition includes the selection of burst length, a burst type, CAS  
Latency,ꢀoperatingꢀmode,ꢀandꢀaꢀwriteꢀburstꢀmode.ꢀTheꢀmodeꢀregisterꢀisꢀprogrammedꢀviaꢀtheꢀLOADꢀMODEꢀREGISTERꢀ  
command and will retain the stored information until it is programmed again or the device loses power.  
The EMR controls the functions beyond those controlled by the MR. These additional functions are special features  
of the Mobile SDRAM. They include temperature-compensated self refresh (TCSR) control, partial-array self refresh  
(PASR),ꢀandꢀoutputꢀdriveꢀstrength.ꢀTheꢀEMRꢀisꢀprogrammedꢀviaꢀtheꢀMODEꢀREGISTERꢀSETꢀcommandꢀwithꢀBA1ꢀ  
= 1 and BA0 = 0 and retains the stored information until it is programmed again or the device loses power. Not  
programming the extended mode register upon initialization will result in default settings for the low-power features.  
The extended mode will default with the temperature sensor enabled, full drive strength, and full array (all 4 banks)  
refresh.  
Mode Register Definition  
The MR is used to define the specific mode of operation of the SDRAM. This definition includes the selection of a  
burst length, a burst type, a CAS latency, an operating mode and a write burst mode, as shown in Figure MODE  
REGISTERꢀDEFINITION.ꢀTheꢀmodeꢀregisterꢀisꢀprogrammedꢀviaꢀtheꢀLOADꢀMODEꢀREGISTERꢀcommandꢀandꢀwillꢀ  
retain the stored information until it is programmed again or the device loses power.  
Mode register bits M0 - M2 specify the burst length, M3 specifies the type of burst (sequential or interleaved), M4 -  
M6ꢀspecifyꢀtheꢀCASꢀlatency,ꢀM7ꢀandꢀM8ꢀspecifyꢀtheꢀoperatingꢀmode,ꢀM9ꢀspecifiesꢀtheꢀWRITEꢀburstꢀmode,ꢀandꢀM10,ꢀ  
M11, and M12 are reserved for future use.  
The mode register must be loaded when all banks are idle, and the controller must wait the specified time before  
initiating the subsequent operation. Violating either of these requirements will result in unspecified operation.  
Integrated Silicon Solution, Inc.  
5
Rev. 00B  
07/21/2010  
IS42VM32160C  
MODE REGISTER DEFINITION  
Address Bus (Ax)  
BA1 BA0 A12 A11 A10 A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
Mode Register (Mx)  
Reserved(1)  
Burst Length  
M2 M1 M0  
M3=0  
M3=1  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1
2
4
8
1
2
4
8
Reserved Reserved  
Reserved Reserved  
Reserved Reserved  
Full Page Reserved  
Burst Type  
M3  
Type  
0
1
Sequential  
Interleaved  
Latency Mode  
M6 M5 M4  
CAS Latency  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reserved  
Reserved  
2
3
Reserved  
Reserved  
Reserved  
Reserved  
Operating Mode  
M8 M7 M6-M0 Mode  
0
0
Defined Standard Operation  
All Other States Reserved  
Write Burst Mode  
M9 Mode  
BA1  
BA0  
Mode Register Definition  
Program Mode Register  
Reserved  
To ensure compatibility with future devices,  
should program A12, A11, A10 = "0"  
0
0
0
1
0
1
Programmed Burst Length  
Single Location Access  
1
1
0
1
Program Extended Mode Register  
Reserved  
Burst Length  
Read and write accesses to the SDRAM are burst oriented, with the burst length being programmable, as shown in  
MODEꢀREGISTERꢀDEFINITION.ꢀTheꢀburstꢀlengthꢀdeterminesꢀtheꢀmaximumꢀnumberꢀofꢀcolumnꢀlocationsꢀthatꢀcanꢀ  
be accessed for a given READ or WRITE command. Burst lengths of 1, 2, 4 or 8 locations are available for both the  
sequential and the interleaved burst types, and a full-page burst is available for the sequential type. The full-page burst  
is used in conjunction with the BURST TERMINATE command to generate arbitrary burst lengths. Reserved states  
should not be used, as unknown operation or incompatibility with future versions may result.  
When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected. All  
accesses for that burst take place within this block, meaning that the burst will wrap within the block if a boundary is  
reached. The block is uniquely selected by A1-A8 (x32) when the burst length is set to two; by A2-A8 (x32) when the  
burst length is set to four; and by A3-A8 (x32) when the burst length is set to eight. The remaining (least significant)  
address bit(s) are used to select the starting location within the block. Full-page bursts wrap within the page if the  
boundary is reached.  
6
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
Burst Type  
Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the  
burst type and is selected via bit M3.  
The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column  
address, as shown in BURST DEFINITION table.  
BURST DEFINITION  
Burst  
Starting Column  
Address  
Order of Accesses Within a Burst  
Type = Sequential Type = Interleaved  
Length  
A 0  
2
4
0
1
0-1  
1-0  
0-1  
1-0  
A 1  
0
A 0  
0
0-1-2-3  
1-2-3-0  
2-3-0-1  
3-0-1-2  
0-1-2-3  
1-0-3-2  
2-3-0-1  
3-2-1-0  
0
1
1
0
1
1
A 2  
0
A 1  
0
A 0  
0
0-1-2-3-4-5-6-7  
1-2-3-4-5-6-7-0  
2-3-4-5-6-7-0-1  
3-4-5-6-7-0-1-2  
4-5-6-7-0-1-2-3  
5-6-7-0-1-2-3-4  
6-7-0-1-2-3-4-5  
7-0-1-2-3-4-5-6  
0-1-2-3-4-5-6-7  
1-0-3-2-5-4-7-6  
2-3-0-1-6-7-4-5  
3-2-1-0-7-6-5-4  
4-5-6-7-0-1-2-3  
5-4-7-6-1-0-3-2  
6-7-4-5-2-3-0-1  
7-6-5-4-3-2-1-0  
NotꢀSupportedꢀ  
0
0
1
0
1
0
8
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Fullꢀ ꢀꢀꢀnꢀ=ꢀA0-A9ꢀ(x8)ꢀꢀ  
Cn,ꢀCnꢀ+ꢀ1,ꢀCnꢀ+ꢀ2ꢀ  
Cn + 3, Cn + 4...  
…Cn - 1,  
Page  
(y)  
(location 0-y)  
Cn…  
CAS Latency  
The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the  
first piece of output data. The latency can be set to two or three clocks.  
If a READ command is registered at clock edge n, and the latency is m clocks, the data will be available by clock  
edge n + m. The DQs will start driving as a result of the clock edge one cycle earlier (n + m - 1), and provided that  
the relevant access times are met, the data will be valid by clock edge n + m. For example, assuming that the clock  
cycle time is such that all relevant access times are met, if a READ command is registered at T0 and the latency  
is programmed to two clocks, the DQs will start driving after T1 and the data will be valid by T2, as shown in CAS  
Latency diagrams.  
Reserved states should not be used as unknown operation or incompatibility with future versions may result.  
Operating Mode  
The normal operating mode is selected by setting M7 and M8 to zero; the other combinations of values for M7 and M8  
are reserved for future use and/or test modes. The programmed burst length applies to both READ and WRITE bursts.  
Integrated Silicon Solution, Inc.  
7
Rev. 00B  
07/21/2010  
IS42VM32160C  
Test modes and reserved states should not be used because unknown operation or incompatibility with future  
versions may result.  
Write Burst Mode  
WhenꢀM9ꢀ=ꢀ0,ꢀtheꢀburstꢀlengthꢀprogrammedꢀviaꢀM0-M2ꢀappliesꢀtoꢀbothꢀREADꢀandꢀWRITEꢀbursts;ꢀwhenꢀM9ꢀ=ꢀ1,ꢀtheꢀ  
programmed burst length applies to READ bursts, but write accesses are single-location (nonburst) accesses.  
CAS LATENCY  
T0  
T1  
T2  
T3  
CLK  
READ  
NOP  
NOP  
COMMAND  
DQ  
t
AC  
D
OUT  
OH  
t
LZ  
t
CAS Latency - 2  
T0  
T1  
T2  
T3  
T4  
CLK  
READ  
NOP  
NOP  
NOP  
COMMAND  
DQ  
tAC  
D
OUT  
OH  
t
LZ  
t
CAS Latency - 3  
DON'T CARE  
UNDEFINED  
8
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
EꢀTENDED MODE REGISTER DEFINITION  
Address Bus (Ax)  
BA1 BA0  
A12  
A11  
A10  
A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
Ext. Mode Reg. (Ex)  
PASR  
E2 E1 E0 Partial Array Self Refresh  
Coverage  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Fully array (4 banks) - (Default)  
Half array (banks 0, 1)  
Quarter array (bank 0)  
Reserved  
Reserved  
One-eighth array (1/2 bank 0)  
One-sixteenth array (1/4 bank 0)  
Reserved  
TCSR  
E4 E3 Max. Case Temp.  
0
0
1
1
0
1
0
1
70oC  
45oC  
15oC  
85oC (Default)  
DS  
E6 E5 Driver Strength  
0
0
1
1
0
1
0
1
Full strength driver (Default)  
Half strength driver  
Quarter strength driver  
Reserved  
set to "0"  
E12 E11 E10 E9 E8 E7 E6-E0  
0
0
0
0
0
0
Valid Normal operation  
All other states reserved  
BA1 BA0 Mode Register Definition  
0
0
1
1
0
1
0
1
Program Mode Register  
Reserved  
Program Extended mode Register  
Reserved  
TheꢀextendedꢀmodeꢀregisterꢀisꢀprogrammedꢀviaꢀtheꢀMODEꢀREGISTERꢀSETꢀcommandꢀ(BA1ꢀ=ꢀ1,ꢀBA0ꢀ=ꢀ0)ꢀandꢀ  
retains the stored information until it is programmed again or the device loses power. The extended mode register  
must be programmed with E7 through E12 set to “0.The extended mode register must be loaded when all banks are  
idle and no bursts are in progress, and the controller must wait the specified time before initiating any subsequent  
operation. Violating either of these requirements results in unspecified operation. The extended mode register must be  
programmed to ensure proper operation.  
Temperature-Compensated Self Refresh (TCSR)  
TCSR allows the controller to program the refresh interval during self refresh mode, according to the case temperature  
of the mobile device. This allows great power savings during self refresh during most operating temperature ranges.  
Only during extreme temperatures would the controller have to select a higher TCSR level that will guarantee data  
during self refresh.  
Integrated Silicon Solution, Inc. ꢀ  
9
Rev. 00B  
07/21/2010  
IS42VM32160C  
Every cell in the DRAM requires refreshing due to the capacitor losing its charge over time. The refresh rate is  
dependent on temperature. At higher temperatures a capacitor loses charge quicker than at lower temperatures,  
requiring the cells to be refreshed more often. Historically, during self refresh, the refresh rate has been set to  
accommodate the worst case, or highest temperature range, expected. Thus, during ambient temperatures, the  
power consumed during refresh was unnecessarily high because the refresh rate was set to accommodate the higher  
temperatures. Setting E4 and E3 allows the DRAM to accommodate more specific temperature regions during self  
refresh. The default for ISSI 512Mb Mobile SDRAM is TCSR = 85°C to guarantee refresh operation. This mode of  
operation has a higher current consumption because the self refresh oscillator is set to refresh the SDRAM cells  
more often than needed. By using an external temperature sensor to determine the operating temperature the Mobile  
SDRAM can be programmed for lower temperature and refresh rates, effectively reducing current consumption by  
a significant amount. There are four temperature settings, which will vary the self refresh current according to the  
selected temperature. This selectable refresh rate will save power when the Mobile DRAM is operating at normal  
temperatures.  
Partial-Array Self Refresh (PASR)  
For further power savings during self refresh, the PASR feature allows the controller to select the amount of memory  
that will be refreshed during self refresh. The refresh options are all banks (banks 0, 1, 2, and 3); two banks (banks  
0 and 1); and one bank (bank 0). In addition partial amounts of bank 0 (half or quarter of the bank) may be selected.  
WRITE and READ commands occur to any bank selected during standard operation, but only the selected banks in  
PASR will be refreshed during self refresh. It’s important to note that data in banks 2 and 3 will be lost when the two-  
bank option is used. Data will be lost in banks 1, 2, and 3 when the one-bank option is used.  
Driver Strength (DS)  
Bits E5 and E6 of the EMR can be used to select the driver strength of the DQ outputs. This value should be set  
according to the application’s requirements. The default is Full Driver Strength.  
Deep Power Down (DPD)  
Deep power down mode is for maximum power savings and is achieved by shutting down power to the entire memory  
array of the mobile device. Data will be lost once deep power down mode is executed.  
DPDꢀmodeꢀisꢀenteredꢀbyꢀhavingꢀallꢀbanksꢀidle,ꢀCSꢀandꢀWEꢀheldꢀlow,ꢀwithꢀRASꢀandꢀCASꢀHIGHꢀatꢀtheꢀrisingꢀedgeꢀofꢀ  
the clock, while CKE is LOW. CKE must be held LOW during DPD mode. To exit DPD mode, CKE must be asserted  
HIGH.ꢀUponꢀexitꢀfromꢀDPDꢀmode,ꢀatꢀleastꢀ200ms of valid clocks with either NOP or COMMAND INHIBIT commands  
are applied to the command bus, followed by a full Mobile SDRAM initialization sequence, is required.  
10  
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
ELECTRICAL SPECIFICATIONS  
ABSOLUTE MAꢀIMUM RATINGS(1)  
Symbol Parameters  
Rating  
-0.35 to +2.8  
-0.35 to +2.8  
-0.35 to Vd d +0.5  
-0.35 to Vd d +0.5  
50  
Unit  
V
V
V
V
Vd d  
Vd d q  
Vin  
Supply Voltage (with respect to Vss)  
Supply Voltage for Output (with respect to Vs s q )  
Input Voltage (with respect to Vss)  
Output Voltage (with respect to Vs s q )  
Short circuit output current  
Vo u t  
Ic s  
mA  
W
Pd  
Power Dissipation (Ta = 25oC)  
1
To p t  
Operating Temperature  
Com.  
Ind.  
0 to +70  
-40 to +85  
°C  
°C  
Ts t g  
Storage Temperature  
–65 to +150  
°C  
Note:  
1.ꢀ StressgreaterthanthoselistedunderABSOLUTEMAXIMUMRATINGSmaycausepermanentdamagetotheꢀ  
device. This is a stress rating only and functional operation of the device at these or any other conditions above  
those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating  
conditions for extended periods may affect reliability.  
2. All voltages are reference to Vss.  
CAPACITANCE  
Symbol  
Parameter  
Min.  
5.0  
5.0  
4
Max.  
7.0  
Unit  
pF  
Cin  
Input Capacitance, address and control pin  
Input Capacitance, CLK pin  
Data Input/Output Capacitance  
Cc l k  
Cio  
7.6  
pF  
6.5  
pF  
Integrated Silicon Solution, Inc.  
11  
Rev. 00B  
07/21/2010  
IS42VM32160C  
DC RECOMMENDED OPERATING CONDITIONS  
IS42VMxxx - 1.8V Operation  
Symbol Parameters  
Min.  
1.7  
1.7  
Typ.  
1.8  
1.8  
Max.  
1.95  
1.95  
Vd d q +0.3  
0.2  
Unit  
V
V
V
V
Vd d  
Supply Voltage  
Vd d q  
I/O Supply Voltage  
Input High Voltage  
Input Low Voltage  
(1)  
Vih  
0.8xVd d q  
-0.3  
(2)  
Vil  
Iil  
Input Leakage Current (0V Vin Vd d )  
Output Leakage Current (Output disabled, 0V Vo u t Vd d )  
Output High Voltage Current (Io h = -100mA)  
Output Low Voltage Current (Io l = 100mA)  
-1  
-1.5  
0.9xVd d q  
+1  
+1.5  
µA  
µA  
V
Io l  
Vo h  
Vo l  
0.2  
V
Notes:  
1. Vih (overshoot): Vih (max) = Vd d q +1.2V (pulse width < 3ns).  
2. Vil (undershoot): Vih (min) = -1.2V (pulse width < 3ns).  
3. All voltages are referenced to Vss.  
12  
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
DC ELECTRICAL CHARACTERISTICS VDD = 1.8V  
Symbol  
Parameter  
Test Condition  
–10  
Unit  
Id d 1(1)  
Operating Current  
One Bank Active, CL = 3, BL = 1,  
120  
mA  
tclk = tCLK(min), tRC = tRC(min)  
CKE Vil (max), tCK = 15ns  
(4)  
Id d 2p  
Precharge Standby Current  
2
2
mA  
mA  
(In Power-Down Mode)  
CS Vd d - 0.2V  
(4)  
Id d 2p s  
Precharge Standby Current  
CKE Vil (max), CLK Vil (max)  
With Clock Stop  
CS Vd d - 0.2V  
(In Power-Down Mode)  
(2)  
Id d 2n  
Precharge Standby Current  
CS Vd d - 0.2V, CKE Vih (min)  
30  
14  
mA  
mA  
(In Non Power-Down Mode)  
Precharge Standby Current  
tCK = 15 ns  
Id d 2n s  
CS Vd d - 0.2V, CKE Vih (min)  
With Clock Stop  
All Inputs Stable  
(In Non-Power Down Mode)  
Active Standby Current  
(2)  
Id d 3p  
CKE Vil (max), CS Vd d - 0.2V  
4
2
mA  
mA  
(In Power-Down Mode)  
Active Standby Current  
tCK = 15 ns  
Id d 3p s  
CKE Vil (max), CLK Vil (max)  
With Clock Stop  
CS Vd d - 0.2V  
(In Power-Down Mode)  
Active Standby Current  
(2)  
Id d 3n  
CS Vd d - 0.2V, CKE Vih (min)  
40  
20  
mA  
mA  
(In Non Power-Down Mode)  
Active Standby Current  
tCK = 15 ns  
Id d 3n s  
CS Vd d - 0.2V, CKE Vih (min)  
With Clock Stop  
All Inputs Stable  
(In Non Power-Down Mode)  
Operating Current  
Id d 4  
All Banks Active, BL =4, CL = 3  
150  
mA  
tCK = tCK(min)  
Id d 5  
Id d 6  
Id d 7  
Auto-Refresh Current  
Self-Refresh Current  
Self-Refresh: CKE = LOW; tc k = tc k (MIN); Full Array, 85oC  
Address, Control, and Data bus inputs are Full Array, 45oC  
tRC = tRC(min), tCLK = tCLK(min)  
220  
2.4  
mA  
mA  
mA  
CKE 0.2V  
2400  
1600  
2000  
1340  
1600  
1080  
1400  
940  
stable  
Half Array, 85oC  
Half Array, 45oC  
1/4th Array, 85oC  
1/4th Array, 45oC  
1/8th Array, 85oC  
1/8th Array, 45oC  
1/16th Array, 85oC  
1/16th Array, 45oC  
1200  
800  
(3,4)  
Iz z  
Deep Power Down Current  
CKE 0.2V  
40  
mA  
Notes:  
1. Id d (max) is specified at the output open condition.  
2. Input signals are changed one time during 30ns.  
3. Izz values shown are nominal at 25oC. Izz is not tested.  
4. Tested after 500ms delay  
Integrated Silicon Solution, Inc.  
13  
Rev. 00B  
07/21/2010  
IS42VM32160C  
AC ELECTRICAL CHARACTERISTICS(1, 2, 3)  
-10  
Symbol Parameter  
Min.  
Max. Unit  
tCK3  
Clock Cycle Time  
CAS Latency = 3  
10  
ns  
tCK2  
tAC3  
CAS Latency = 2  
CAS Latency = 3  
12  
8
ns  
ns  
Access Time From CLK  
tAC2  
tCHI  
tCL  
CAS Latency = 2  
9
ns  
ns  
ns  
ns  
CLKꢀHIGHꢀLevelꢀWidth  
CLK LOW Level Width  
Output Data Hold Time  
2.5  
2.5  
2.7  
tOH3  
CAS Latency = 3  
CAS Latency = 2  
tOH2  
tLZ  
2.7  
0
ns  
ns  
ns  
Output LOW Impedance Time  
tHZ  
OutputꢀHIGHꢀImpedanceꢀTime CAS Latency = 3  
2.7  
8.0  
CAS Latency = 2  
Input Data Setup Time (2)  
Input Data Hold Time (2)  
Address Setup Time (2)  
Address Hold Time (2)  
CKE Setup Time (2)  
2.7  
1.5  
1.0  
1.5  
1.0  
1.5  
1.0  
1.5  
9.0  
tDS  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tDH  
tAS  
tAH  
tCKS  
tCKH  
tCS  
CKE Hold Time (2)  
Command Setup Time (CS,  
RAS, CAS, WE, DQM)(2)  
Command Hold Time (CS,  
RAS, CAS, WE, DQM)(2)  
Command Period (REF to REF  
/ ACT to ACT)  
tCH  
1.0  
90  
60  
24  
24  
20  
20  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
tRC  
tRAS  
tRP  
Command Period (ACT to  
PRE)  
100K  
Command Period (PRE to  
ACT)  
tRCD  
tRRD  
tDPL  
tDAL  
Active Command to Read/  
Write Command Delay Time  
Command Period (ACT [0] to  
ACT [1])  
Input Data to Precharge  
Command Delay Time  
Input Data to Active/Refresh  
Command Delay Time (During  
Auto-Precharge)  
48  
ns  
tMRD  
tDDE  
tSRX  
tT  
Mode Register Program Time  
Power Down Exit Setup Time  
Self-Refresh Exit Time  
Transition Time  
20  
10  
80  
0.3  
ns  
ns  
ns  
ns  
ms  
1.2  
64  
tREF  
RefreshꢀCycleꢀTimeꢀ(8192)  
Notes:  
1. The power-on sequence must be executed before starting memory operation.  
2. Measured with tT = 1 ns. If clock rising time is longer than 1ns, (tR /2 - 0.5) ns should be added to the parameter.  
3. The reference level is 1.4V when measuring input signal timing. Rise and fall times are measured between  
Vih(min.) and Vil (max).  
14  
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
OPERATING FREQUENCY / LATENCY RELATIONSHIPS  
SYMBOL PARAMETER  
-10  
10  
100  
3
UNITS  
ns  
Clock Cycle Time  
Operating Frequency  
MHz  
tc a c  
tr c d  
tr a c  
tr c  
CAS Latency  
cycle  
cycle  
cycle  
cycle  
cycle  
cycle  
cycle  
cycle  
Active Command To Read/Write Command Delay Time  
RAS Latency (tr c d + tc a c )  
3
CAS Latency = 3  
6
Command Period (REF to REF / ACT to ACT)  
Command Period (ACT to PRE)  
Command Period (PRE to ACT)  
Command Period (ACT[0] to ACT [1])  
9
tr a s  
tr p  
6
3
tr r d  
tc c d  
2
Column Command Delay Time  
(READ, READA, WRIT, WRITA)  
1
td p l  
td a l  
Input Data To Precharge Command Delay Time  
2
5
cycle  
cycle  
Input Data To Active/Refresh Command Delay Time  
(During Auto-Precharge)  
BurstꢀStopꢀCommandꢀToꢀOutputꢀinꢀHIGH-ZꢀDelayꢀTimeꢀ  
tr b d  
tw b d  
tr q l  
tw d l  
CAS Latency = 3  
CAS Latency = 3  
CAS Latency = 3  
3
0
3
0
cycle  
cycle  
cycle  
cycle  
(Read)  
Burst Stop Command To Input in Invalid Delay Time  
(Write)  
PrechargeꢀCommandꢀToꢀOutputꢀinꢀHIGH-ZꢀDelayꢀTimeꢀ  
(Read)  
Precharge Command To Input in Invalid Delay Time  
(Write)  
Last Output To Auto-Precharge Start Time (Read)  
DQM To Output Delay Time (Read)  
tp q l  
tq m d  
td m d  
tm r d  
-2  
2
cycle  
cycle  
cycle  
cycle  
DQM To Input Delay Time (Write)  
0
Mode Register Set To Command Delay Time  
2
Integrated Silicon Solution, Inc.  
15  
Rev. 00B  
07/21/2010  
IS42VM32160C  
Ordering Information – Vd d = 1.8V  
Commercial Range: (0°C to +70°C)  
Frequency  
Speed (ns) Order Part No.  
10 IS42VM32160C-10BL  
Package  
100 MHz  
8x13mmꢀBGA,ꢀLead-free  
Industrial Range: (-40°C to +85°C)  
Frequency  
Speed (ns) Order Part No.  
10 IS42VM32160C-10BLI  
IS42VM32160C-10BI  
Package  
100 MHz  
8x13mmꢀBGA,ꢀLead-free  
8x13mmꢀBGA  
*Contact ISSI for leaded parts support.  
16  
Integrated Silicon Solution, Inc.  
Rev. 00B  
07/21/2010  
IS42VM32160C  
Integrated Silicon Solution, Inc.  
17  
Rev. 00B  
07/21/2010  

相关型号:

IS42VM32160C-10BL

512Mb Mobile Synchronous DRAM
ISSI

IS42VM32160C-10BL-TR

Synchronous DRAM, 16MX32, 8ns, CMOS, PBGA90,
ISSI

IS42VM32160C-10BLI

Synchronous DRAM, 16MX32, 8ns, CMOS, PBGA90, 13 X 8 MM, 0.80 MM PITCH, LEAD FREE, MS-207, FBGA-90
ISSI

IS42VM32160C-10BLI-TR

Synchronous DRAM, 16MX32, 8ns, CMOS, PBGA90,
ISSI

IS42VM32160C-75BI

Synchronous DRAM, 16MX32, 5.4ns, CMOS, PBGA90, 8 X 13 MM, 0.80 MM PITCH, MS-207, FBGA-90
ISSI

IS42VM32160C-75BL

Synchronous DRAM, 16MX32, 5.4ns, CMOS, PBGA90, 8 X 13 MM, 0.80 MM PITCH, LEAD FREE, MS-207, FBGA-90
ISSI

IS42VM32160C-75BLI

Synchronous DRAM, 16MX32, 5.4ns, CMOS, PBGA90, 8 X 13 MM, 0.80 MM PITCH, LEAD FREE, MS-207, FBGA-90
ISSI

IS42VM32160D-6BLI

Synchronous DRAM, 16MX32, 5.4ns, CMOS, PBGA90, 8 X 13 MM, LEAD FREE, MO-207, TFBGA-90
ISSI

IS42VM32160D-75BLI

Synchronous DRAM, 16MX32, 6ns, CMOS, PBGA90, 8 X 13 MM, LEAD FREE, MO-207, TFBGA-90
ISSI

IS42VM32160E-6BLA1

Synchronous DRAM, 16MX32, 6ns, CMOS, PBGA90, 8 X 13 MM, LEAD FREE, MO-207, TFBGA-90
ISSI

IS42VM32160E-6BLA2

Synchronous DRAM, 16MX32, 6ns, CMOS, PBGA90, 8 X 13 MM, LEAD FREE, MO-207, TFBGA-90
ISSI

IS42VM32160E-6BLI

Synchronous DRAM, 16MX32, 5.5ns, CMOS, PBGA90, 8 X 13 MM, LEAD FREE, MO-207, TFBGA-90
ISSI