IS43R32400A-6B [ISSI]

4Meg x 32 128-MBIT DDR SDRAM; 4Meg ×32 128兆位的DDR SDRAM
IS43R32400A-6B
型号: IS43R32400A-6B
厂家: INTEGRATED SILICON SOLUTION, INC    INTEGRATED SILICON SOLUTION, INC
描述:

4Meg x 32 128-MBIT DDR SDRAM
4Meg ×32 128兆位的DDR SDRAM

动态存储器 双倍数据速率
文件: 总25页 (文件大小:1286K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
IS43R32400A  
ISSI  
PRELIMINARY INFORMATION  
FEBRUARY 2006  
4Meg x 32  
128-MBIT DDR SDRAM  
FEATURES  
DEVICE OVERVIEW  
ISSI’s 128-Mbit DDR SDRAM achieves high-speed  
data transfer using pipeline architecture and two data  
word accesses per clock cycle. The 134,217,728-bit  
memory array is internally organized as four banks of  
32M-bit to allow concurrent operations. The pipeline  
allows Read and Write burst accesses to be virtually  
continuous, with the option to concatenate or truncate  
the bursts. The programmable features of burst  
length, burst sequence and CAS latency enable  
further advantages. The device is available in 32-bit  
data word size. Input data is registered on the I/O pins  
on both edges of Data Strobe signal(s), while output  
data is referenced to both edges of Data Strobe and  
both edges of CLK. Commands are registered on the  
positive edges of CLK. Auto Refresh, Active Power  
Down, and Pre-charge Power Down modes are  
enabled by using clock enable (CKE) and other inputs  
in an industry-standard sequence. All input and  
output voltage levels are compatible with SSTL 2.  
Clock Frequency: 200, 166, 100 MHz  
Power supply (VDD and VDDQ): 2.5V  
SSTL 2 interface  
Four internal banks to hide row Pre-charge  
and Active operations  
Commands and addresses register on positive  
clock edges (CLK)  
Bi-directional Data Strobe signal for data cap-  
ture  
Differential clock inputs (CLK and CLK) for  
two data accesses per clock cycle  
Data Mask feature for Writes supported  
DLL aligns data I/O and Data Strobe transitions  
with clock inputs  
Half-strength and Matched drive strength  
options  
IS43R32400A  
1M x32x4 Banks  
VDD: 2.5V  
Programmable burst length for Read and Write  
operations  
Programmable CAS Latency (3, 4, 5 clocks)  
VDDQ: 2.5V  
Programmable burst sequence: sequential or  
144-ballBGA  
interleaved  
Burst concatenation and truncation supported  
for maximum data throughput  
KEY TIMING PARAMETERS  
Auto Pre-charge option for each Read or Write  
burst  
Parameter  
-5  
-6  
Unit  
CLK Cycle Time (min.)  
CAS Latency = 5  
4096 refresh cycles every 32ms  
Auto Refresh and Self Refresh Modes  
5
5
5
6
6
6
ns  
ns  
ns  
CAS Latency = 4  
Pre-charge Power Down and Active Power  
CAS Latency = 3  
Down Modes  
CLK Frequency (max.)  
CAS Latency = 5  
Industrial Temperature Availability  
Lead-free Availability  
200  
200  
200  
166  
166  
166  
MHz  
MHz  
MHz  
CAS Latency = 4  
CAS Latency = 3  
Copyright © 2006 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time  
without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to  
obtain the latest version of this device specification before relying on any published information and before placing orders for products.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
1
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
FUNCTIONAL BLOCK DIAGRAM (X32)  
CLK  
CLK  
CKE  
CS  
RAS  
CAS  
COMMAND  
DECODER  
DM0-DM3  
4
DATA IN  
BUFFER  
&
CLOCK  
GENERATOR  
32  
32  
I/O 0-31  
REFRESH  
CONTROLLER  
DQS0-DQS3  
WE  
MODE  
4
REGISTER  
V
DD/VDDQ  
ss/Vss  
SELF  
DATA OUT  
BUFFER  
REFRESH  
V
Q
A11  
A10  
CONTROLLER  
14  
32  
32  
A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
REFRESH  
COUNTER  
2
4096  
4096  
12  
MEMORY CELL  
ARRAY  
4096  
4096  
12  
BANK 0  
ROW  
ROW  
ADDRESS  
BUFFER  
12  
BA0  
ADDRESS  
BA1  
LATCH  
12  
14  
SENSE AMP I/O GATE  
256  
(x 32)  
COLUMN  
ADDRESS LATCH  
BANK CONTROL LOGIC  
8
BURST COUNTER  
COLUMN DECODER  
COLUMN  
ADDRESS BUFFER  
8
2
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
PIN CONFIGURATION  
PACKAGE CODE: B 144-BALL FBGA (Top View)  
(12.00 mm x 12.00 mm Body, 0.8 mm Ball Pitch)  
1 2 3 4 5 6 7 8 9 10 11 12  
A
B
C
D
E
F
DQS0 DM0 VSSQ DQ3 DQ2 DQ0 DQ31 DQ29 DQ28 VSSQ DM3 DQS3  
DQ4 VDDQ NC VDDQ DQ1 VDDQ VDDQ DQ30 VDDQ NC VDDQ DQ27  
DQ6 DQ5 VSSQ VSSQ VSSQ VDD VDD VSSQ VSSQ VSSQ DQ26 DQ25  
DQ7 VDDQ VDD VSS VSSQ VSS VSS VSSQ VSS VDD VDDQ DQ24  
DQ17 DQ16 VDDQ VSSQ VSS VSS VSS VSS VSSQ VDDQ DQ15 DQ14  
DQ19 DQ18 VDDQ VSSQ VSS VSS VSS VSS VSSQ VDDQ DQ13 DQ12  
G
H
J
DQS2 DM2  
NC VSSQ VSS VSS VSS VSS VSSQ NC  
DM1 DQS1  
DQ21 DQ20 VDDQ VSSQ VSS VSS VSS VSS VSSQ VDDQ DQ11 DQ10  
DQ22 DQ23 VDDQ VSSQ VSS VSS VSS VSS VSSQ VDDQ DQ9 DQ8  
K
L
CAS  
RAS  
CS  
WE VDD VSS A10 VDD VDD  
NC VSS VDD  
NC  
NC  
NC  
NC  
NC  
NC  
BA1  
A0  
A2  
A1  
A11  
A3  
A9  
A5  
A6  
NC  
A7  
CK  
A8  
CK  
M
BA0  
A4  
CKE VREF  
Note: Vss balls inside the dotted box are optional for purposes of thermal dissipation.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
3
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
PIN FUNCTIONS  
Symbol  
A0-A11  
Type  
Input Pin  
Function (In Detail)  
Address inputs are sampled during several commands. During an Active  
command, A0-A11 select a row to open. During a Read or Write command,  
A0-A7 select a starting column for a burst. During a Pre-charge command,  
A8 determines whether all banks are to be pre-charged, or a single bank.  
During a Load Mode Register command, the address inputs select an  
operating mode.  
BA0, BA1  
Input Pin  
Bank Address inputs are used to select a bank during Active, Pre-charge,  
Read, or Write commands. During a Load Mode Register command, BA0  
and BA1 are used to select between the Base or Extended Mode Register  
CAS  
Input Pin  
Input Pin  
CAS is Column Access Strobe, which is an input to the device command  
along with RAS and WE. See “Command Truth Table” for details.  
CKE  
Clock Enable: CKE High activates and CKE Low de-activates internal clock  
signals and input/output buffers. When CKE goes Low, it can allow Self  
Refresh, Pre-charge Power Down, and Active Power Down. CKE must be  
High during entire Read and Write accesses. Input buffers except CLK,  
CLK, and CKE are disabled during Power Down. CKE uses an SSTL 2  
input, but will detect a LVCMOS Low level after VDD is applied.  
CLK, CLK  
CS  
Input Pin  
Input Pin  
Input Pin  
All address and command inputs are sampled on the rising edge of the  
clock input CLK and the falling edge of the differential clock input CLK.  
Output data is referenced from the crossings of CLK and CLK.  
The Chip Select input enables the Command Decoding block of the device.  
When CS is disabled, a NOP occurs. See “Command Truth Table” for  
details. Multiple DDR SDRAM devices can be managed with CS.  
These are the Data Mask inputs. During a Write operation, the Data Mask  
input allows masking of the data bus. DM is sampled on each edge of DQS.  
There are four Data Mask input pins for the x32 DDR SDRAM. Each input  
applies to DQ0-DQ7, DQ8-DQ15, DQ16-DQ23, or DQ24-DQ31.  
DM0-DM3  
DQS0-DQS3 Input/Output Pin  
These are the Data Strobe inputs. The Data Strobe is used for data capture.  
During a Read operation, the DQS output signal from the device is edge-  
aligned with valid data on the data bus. During a Write operation, the DQS  
input should be issued to the DDR SDRAM device when the input values on  
DQ inputs are stable. There are four Data Strobe pins for the x32 DDR  
SDRAM. Each of the four Data Strobe pins applies to DQ0-DQ7, DQ8-  
DQ15, DQ16-DQ23, or DQ24-DQ31.  
DQ0-DQ31  
Input/Output Pin  
The pins DQ0 to DQ31 represent the data bus. For Write operations, the  
data bus is sampled on Data Strobe. For Read operations, the data bus is  
sampled on the crossings of CK and CK.  
NC  
No Connect: This pin should be left floating. These pins could be used for  
256Mbit or higher density DDR SDRAM.  
RAS  
WE  
Input Pin  
Input Pin  
RAS is Row Access Strobe, which is an input to the device command  
along with CAS and WE. See “Command Truth Table” for details.  
WE is Write Enable, which is an input to the device command along with  
RAS and CAS. See “Command Truth Table” for details.  
VDDQ  
VDD  
VREF  
VSSQ  
VSS  
Power Supply Pin  
Power Supply Pin  
Power Supply Pin  
Power Supply Pin  
Power Supply Pin  
VDDQ is the output buffer power supply.  
VDD is the device power supply.  
VREF is the reference voltage for SSTL 2.  
VSSQ is the output buffer ground.  
VSS is the device ground.  
4
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
COMMAND TRUTH TABLE  
Function  
CKE (n - 1) CKE (n)  
CS  
H
L
RAS  
x
CAS  
x
WE  
x
BA1  
x
BA0 Address  
Device Deselect (NOP)  
No Operation (NOP)  
Burst Stop(2)  
Read(3)  
Write(3)  
H
H
H
H
H
H
H
H
H
H
H
L
x
x
H
x
x
x
x
x
x
x
x
x
x
x
x
x
H
H
H
H
L
H
H
L
H
L
x
L
x
x
x
L
H
L
V
V
V
V
x
V
V
V
V
x
V
V
V
x
L
L
Bank and Row Activate  
Pre-charge select bank  
Pre-charge all banks  
Load Mode Register (Base)  
Load Extended Mode Register  
Auto Refresh  
L
H
H
H
L
H
L
L
L
L
L
L
x
L
L
L
L
L
H
x
V
V
x
L
L
L
L
L
L
L
L
H
H
x
Self Refresh  
L
L
L
x
x
x
Notes:  
1. H = VIH, L = VIL, x = VIH or VIL, V = Valid Data.  
2. This command only applies to Read command with Auto Pre-charge disabled.  
3. Auto Pre-charge is enabled with A8 = H (x32).  
DATA MASK TRUTH TABLE  
Function  
CKE (n - 1) CKE (n)  
DM0  
DM1  
DM2  
DM3  
Write Enable for Data Byte DQ0-DQ7  
Write Disable for Data Byte DQ0-DQ7  
Write Enable for Data Byte DQ8-DQ15  
Write Disable for Data Byte DQ8-DQ15  
Write Enable for Data Byte DQ16-DQ23  
Write Disable for Data Byte DQ16-DQ23  
Write Enable for Data Byte DQ24-DQ31  
Write Disable for Data Byte DQ24-DQ31  
H
H
H
H
H
H
H
H
x
x
x
x
x
x
x
x
L
H
x
x
x
x
x
x
x
x
L
H
x
x
x
x
x
x
x
x
L
H
x
x
x
x
x
x
x
x
L
H
Notes:  
1. H = VIH, L = VIL, x = VIH or VIL, V = Valid Data.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
5
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
DETAILED COMMAND TRUTH TABLE - SAME BANKS  
Function (n)  
Command (n)  
Prior State (n - 1) CKE (n - 1) CKE (n) CS RAS CAS WE  
NOP or Continue  
previous operation  
NOP or Continue  
previous operation  
Activate row  
Deselect  
Any  
H
H
H
X
X
X
NOP  
Any  
H
H
L
H
H
H
Active  
Idle  
Idle  
Idle  
H
H
H
H
H
H
L
L
L
L
L
L
H
L
L
H
H
L
Issue Auto Refresh  
Load the Base/  
Auto Refresh  
Load Mode Register  
Extended Mode Register  
Start Read Burst  
Read  
Row active  
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
L
Read  
Read underway  
Write underway  
Row active  
Read  
Start Write Burst  
Write  
Write(1)  
Read underway  
Write underway  
Row active  
L
Write  
L
De-activate Row,  
start Pre-charge  
Pre-charge  
L
Truncate Read Burst,  
start Pre-charge  
Pre-charge  
Read underway  
Write underway  
Read underway  
H
H
H
H
H
H
L
L
L
L
L
H
H
H
L
L
L
Truncate Write Burst,  
start Pre-charge  
Pre-charge  
Terminate Read Burst  
Burst Terminate  
H
Note:  
1. A Write command may be terminated only at the completion of the Read burst. However, a Burst Terminate can be transmitted  
to end the Read burst early so that a Write command can be asserted.  
6
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
DETAILED COMMAND TRUTH TABLE - DIFFERENT BANKS (bank b, then bank g)  
Function (n)  
Command (n)  
Prior State (n - 1) CKE (n - 1) CKE (n) CS RAS CAS WE  
NOP or Continue  
previous operation  
NOP or Continue  
previous operation  
Issue any command to  
bank g otherwise valid  
Start Read Burst in  
bank g  
Deselect  
Any  
Any  
Idle  
H
H
H
H
H
H
H
H
H
X
H
X
H
X
H
X
L
X
H
X
H
NOP  
L
Any command  
Read  
X
L
Row in bank b  
active, activating,  
or pre-charging  
Read  
Read  
Read  
Read  
Write  
Read underway in  
bank b (Auto Pre-  
charge disabled)  
Write underway in  
bank b (Auto Pre-  
charge disabled)  
Read underway in  
bank b (Auto Pre-  
charge enabled)  
Write underway in  
bank b (Auto Pre-  
charge enabled)  
Row in bank b active,  
activating, or  
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
H
H
H
H
L
Start Write Burst in bank g  
pre-charging  
Write(1)  
Write  
Read underway in  
bank b (Auto Pre-  
charge disabled)  
Write underway in  
bank b (Auto Pre-  
charge disabled)  
Read underway in  
bank b (Auto Pre-  
charge enabled)  
Write underway in  
bank b (Auto Pre-  
charge enabled)  
L
L
Write(1)  
Write  
L
L
Integrated Silicon Solution, Inc. — 1-800-379-4774  
7
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
DETAILED COMMAND TRUTH TABLE - DIFFERENT BANKS (bank b, then bank g) -cont.  
Function (n)  
Command (n)  
Prior State (n - 1) CKE (n - 1) CKE (n) CS RAS CAS WE  
Start Pre-charge  
Pre-charge  
Row in bank b active,  
activating, or  
pre-charging  
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
H
H
H
H
H
L
L
L
L
L
Pre-charge  
Pre-charge  
Pre-charge  
Pre-charge  
Read underway in  
bank b (Auto Pre-  
charge disabled)  
Write underway in  
bank b (Auto Pre-  
charge disabled)  
Read underway in  
bank b (Auto Pre-  
charge enabled)  
Write underway in  
bank b (Auto Pre-  
charge enabled)  
Note:  
1. A Write command may be terminated only at the completion of the Read burst. However, a Burst Terminate can be transmitted  
to end the Read burst early so that a Write command can be asserted.  
DETAILED COMMAND TRUTH TABLE - LOW POWER MODES  
Function (n)  
Command (n)  
Prior State (n - 1) CKE (n - 1) CKE (n) CS  
RAS CAS WE  
Maintain Power Down don’t care  
Power Down Mode  
Self Refresh Mode  
L
L
L
L
H
L
L
H
H
L
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Maintain Self Refresh  
Exit Power Down  
don’t care  
Deselect or NOP Power Down  
Exit Self Refresh Mode Deselect or NOP Self Refresh Mode  
Enter Pre-Charge  
Power Down Mode  
Enter Active Power  
Down Mode  
Deselect or NOP All Banks Idle  
Deselect or NOP Bank(s) Active  
H
H
L
L
X
L
X
L
X
L
X
H
Enter Self Refresh  
Mode  
Auto Refresh  
All Banks Idle  
8
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
ABSOLUTE MAXIMUM RATINGS(1)  
Symbol  
Parameters  
Rating  
Unit  
VDD MAX  
VDDQ MAX  
VIN, VREF  
VOUT  
Maximum Supply Voltage  
–0.3 to +3.6  
0.3 to +3.6  
–0.3 to VDDQ + 0.3  
–0.3 to VDDQ + 0.3  
2
V
V
V
Maximum Supply Voltage for Output Buffer  
Input Voltage, Reference Voltage  
Output Voltage  
Allowable Power Dissipation  
Output Shorted Current  
V
PD MAX  
ICS  
W
mA  
°C  
50  
0 to +70  
–40 to +85  
TOPR  
Operating Temperature  
Com.  
Ind.  
TSTG  
Storage Temperature  
–55 to +150  
°C  
Notes:  
1. Stress greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This  
is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the  
operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods  
may affect reliability.  
2. All voltages are referenced to Vss.  
RECOMMENDED DC OPERATING CONDITIONS (SSTL_2 Input/Output, TA = 0oC to +70oC)  
Symbol Parameter  
Test Condition  
Min  
2.375  
2.375  
Typ.  
2.500  
2.500  
VREF  
Max  
2.625  
2.625  
Unit  
V
V
VDD  
VDDQ  
VTT  
VIH  
Supply Voltage  
I/O Supply Voltage  
I/O Termination Voltage  
Input High Voltage  
VREF - 0.04  
VREF + 0.15  
VSSQ - 0.3  
0.49 x VDDQ  
-5  
VREF + 0.04  
VDDQ + 0.3  
VDDQ - 0.15  
V
V
VIL  
Input Low Voltage  
V
VREF  
IIL  
I/O Reference Voltage  
Input Leakage Current  
0.5 x VDDQ 0.51 x VDDQ  
V
µA  
0
VREF  
VDD, with all inputs  
at VSS, except tested input  
Output Leakage Current Output disabled;  
0V  
5
IOL  
-5  
VTT + 0.76  
5
µA  
V
VOUT VDDQ  
VOH  
Output High Voltage  
Level  
IOH = -15.2mA  
VOL  
Output Low Voltage  
Level  
IOL = +15.2mA  
VREF - 0.76  
V
Note:  
1. VDDQ must always be less than or equal to VDD.  
CAPACITANCE CHARACTERISTICS (At TA = 0 to +25°C, VDD = VDDQ = 2.5V, f = 1 MHz)  
Symbol  
Parameter  
Min.  
Max.  
Unit  
CIN1  
CIN2  
CIN3  
COUT  
Input Capacitance: Address, B0, B1  
Input Capacitance:All other input pins  
Data Mask Input/Output Capacitance: DM0  
4
3
6
6
5
5
8
8
pF  
pF  
pF  
pF  
-
DM3  
Data Input/Output Capacitance: DQ and DQS  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
9
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
DC ELECTRICAL CHARACTERISTICS (VDD = 2.5V +/- 5%, TA = 0oC to +70oC)  
SymbolParameter  
Test Condition  
Unit  
IDD0  
Operating Current  
One bank operation; Active-Precharge; DQ, DM and DQS  
inputs change once per clock cycle; Address and Control  
inputs change once per two clock cycles; tRC = tRC (min);  
tCK = tCK (min)  
160 mA  
IDD1  
Operating Current  
One bank operation; Active-Read-Precharge; BL = 4; CL = 4;  
Address and Control inputs change once per clock cycle;  
tRCDRD = 4 x tCK; tRC = tRC (min); tCK = tCK (min);  
IOUT = 0mA;  
240 mA  
40 mA  
IDD2P  
IDD2N  
Precharge Power-Down  
Standby Current  
All banks Idle; tCK = tCK (min); CKE = Low  
Idle Standby Current  
All banks idle; Address and control inputs change once per  
clock cycle; CKE = High; CS = High (Deselect); VIN = VREF  
for DQ, DQS, and DM; tCK = tCK (min)  
80 mA  
40 mA  
IDD3P  
IDD3N  
Active Power-Down  
Standby Current  
One bank Active; CKE = Low; tCK = tCK (min)  
Active Standby Current  
One bank Active; CS = High; CKE = High; Address and  
Control inputs change once per clock cycle; DQ, DQS, and  
DM change twice per clock cycle; tRC = tRC (max);  
tCK = tCK (min)  
100 mA  
420 mA  
IDD4R  
IDD4W  
Operating Current  
Burst Read  
One bank Active; BL = 2; Address and Control inputs  
change once per clock cycle; tCK = tCK (min); IOUT = 0mA  
One bank Active; BL = 2; Address and Control inputs change  
once per clock cycle; DQ, DQS, DM change twice per clock  
cycle; tCK = tCK (min)  
Operating Current  
Burst Write  
270 mA  
280 mA  
IDD5  
IDD6  
IDD7  
Auto Refresh Current  
Self Refresh Current  
Operating Current  
tRC = tRFC (min); tCK = tCK (min)  
CKE  
0.2V; tCK = tCK (min)  
3
mA  
Four bank interleaved Reads with Auto Precharge; BL = 4;  
Address and Controls inputs change per Read, Write, or  
Active command; tRC = tRC (min); tCK = tCK (min)  
550 mA  
Notes:  
1.Operating outside the “Absolute Maximum Ratings” may lead to temporary or permanent device failure.  
2.Power up sequence describe in “Initialization” section.  
3. All voltages are referenced to VSS.  
10  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
AC ELECTRICAL CHARACTERISTICS (VDD = 2.5V +/- 5%, TA = 0oC to +70oC)  
-5  
-6  
Min. Max.  
Symbol Parameter  
TestCondition  
CL = 3  
Min.  
5
Max.  
10  
10  
Unit  
ns  
tCK  
Clock Cycle Time  
6
6
10  
10  
CL = 4  
5
ns  
CL = 5  
5
10  
6
10  
ns  
tCH  
Clock High Level Width  
Clock Low Level Width  
0.45  
0.45  
0.55  
0.55  
0.7  
0.85  
0.45  
1.1  
0.6  
1.15  
0.45  
0.45  
-0.7  
-0.85  
0.9  
0.4  
0.85  
0
0.55  
0.55  
0.7  
0.85  
0.45  
1.1  
0.6  
1.15  
tCK  
tCK  
ns  
tCL  
tDQSCK  
tAC  
DQS-Out Access Time from CLK, CLK  
Output Access Time from CLK, CLK  
DQS-DQSkew  
ReadPreamble  
ReadPostamble  
CLK to Valid DQS-In  
DQS-In Setup Time  
DQS-In Hold Time  
DQS Write Post Postamble  
DQS-In High Level Pulse Width  
DQS-In Low Level Pulse Width  
Address and Control Input Setup Time  
DQ and DM Setup Time to DQS  
DQ and DM Hold Time to DQS  
Clock Half Period  
Output DQS Valid Window  
Row Cycle Time  
Refresh Row Cycle Time  
Row Active Time  
-0.7  
-0.85  
0.9  
0.4  
0.85  
0
0.35  
0.4  
0.4  
0.4  
0.9  
0.5  
ns  
ns  
tDQSQ  
tRPRE  
tRPST  
tDQSS  
tWPRES  
tWPREH  
tWPST  
tDQSH  
tDQSL  
tIS  
tCK  
tCK  
tCK  
ns  
0.35  
0.4  
0.4  
0.4  
0.9  
0.5  
0.7  
tCH or tCL  
tHP - 0.55  
11  
ns  
0.6  
0.6  
0.6  
0.6  
0.6  
0.6  
tCK  
tCK  
tCK  
ns  
tDS  
ns  
ns  
ns  
ns  
tDH  
0.7  
tHP  
tCH or tCL  
tQH  
tHP - 0.5  
tRC  
12  
14  
8
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
ns  
tRFC  
12  
7
tRAS  
tRCDRD  
tRCDWR  
tRP  
100K  
120K  
RAS to CAS Delay in Read  
RAS to CAS Delay in Write  
RowPre-chargeTime  
Row Active to Row Active Delay  
Write Recovery Time  
Last Data-In to Read Command  
Column Address to Column Address Delay  
ModeRegisterLoadDelay  
4
4
2
3
2
2
2
1
2
7
200  
2
3
2
2
2
1
2
7
tRRD  
tWR  
tCDLR  
tCCD  
tMRD  
tDAL  
Auto Pre-charge Write Recovery + Pre-charge  
Self Refresh Exit to Read Command Delay  
Power Down Exit Time  
tXSA  
tPDEX  
tREF  
7.8  
200  
tIS + 2 x tCK  
tIS + 2 x tCK —  
Refresh Interval Time  
7.8  
µs  
Notes:  
1. Operating outside the “Absolute Maximum Ratings” may lead to temporary or permanent device failure.  
2. Power up sequence describe in “Initialization” section.  
3. All voltages are referenced to Vss.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
11  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
AC TEST CONDITIONS  
OutputLoad  
V
TT = 0.5 x VDDQ  
25Ω  
Z = 25Ω  
Output  
30 pF  
VREF = 0.5 x VDDQ  
AC TEST CONDITIONS  
Parameter  
Unit  
Input Signal Levels  
Input Signal Slew Rate  
Input Timing Reference Level  
Output Timing Measurement Reference Level  
CLK and CLK Signal Maximum Peak Swing  
Reference Level of Input/Ouput Signals  
VREF + 0.4V / VREF - 0.4V  
1V / ns  
VREF  
VTT  
1.5V  
0.5 x VDDQ  
12  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
INITIALIZATION  
FUNCTIONAL DESCRIPTION  
The DDR SDRAM must be powered-on and initial-  
The 128Mbit DDR SDRAM is a high-speed CMOS  
device with four banks that operate at 2.5V. Each  
32Mbit bank is organized as 4,096 rows of 256  
columns for the x32 options. Pre-fetch architecture  
allows Read and Write accesses to be double-data  
rate and burst oriented. Accesses start at a selected  
column location and continue every half-clock cycle  
for a programmed number of times. The Read or  
Write operation begins with an Active command to  
transmit the selected bank and row (A0-A11 bits are  
sampled). This is followed by a Read or Write  
command to sample the address bits again to  
determine the first column to access. When access  
to the memory is not necessary, the device can be  
put into a Power Down mode in which current con-  
sumption is minimized. Prior to normal operation, the  
device must be initialized in a defined procedure to  
function properly. The following sections describe  
the steps of initialization, the mode register defini-  
ized in a series of defined steps for proper operation.  
First, power is applied simultaneously to VDD and  
VDDQ. After these reaching stable values, a VREF  
is ramped up. If this sequence is not followed, latch-  
up could occur and cause damage to the device.  
The input CKE must be asserted and held to a  
LVCMOS Low level during this time to prevent  
unwanted commands from being executed. The  
outputs I/O and DQS remain in high impedance until  
driven during a normal operation. Once VDD, VDDQ,  
VREF, and CKE are stable values, the clock inputs  
can begin to be applied. For a time period of at least  
200µs, valid CLK and CLK cycles must be applied  
prior to any command being issued to the device.  
CKE needs to then be raised to SSTL 2 logic High  
and issue a NOP or Deselect command to initialize  
the internal logic of the DRAM. Next, a Pre-charge  
All command is given to the device, followed by a  
NOP/Deselect command on each clock cycle for at  
least tRP. The Load Extended Mode Register  
should be issued to enable DLL, followed by another  
series of NOP/Deselect commands for at least tMRD.  
After this time, the Load Mode Register command  
should be issued to reset the DLL, again followed by  
a series of NOP or Deselect commands for at least  
tMRD. (Note: whenever the DLL is reset, 200 clock  
cycles must occur prior to any Read command.) The  
Pre-charge command is then issued, with NOP/  
Deselect commands for at least tRP. Next, two Auto-  
Refresh commands are issued, each followed by  
NOP/Deselect commands for at least tRFC. At this  
point, the JEDEC specification recommends that a  
DDR SDRAM receive another Load Mode Register  
command to clear the DLL, with NOP/Deselect  
commands for at least tMRD. The device is now  
ready to receive a valid command for normal opera-  
tions, command descriptions, and device operation.  
tion.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
13  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
loaded only if all banks are idle. After the Load  
MODE REGISTER DEFINITION  
Mode Register command, a minimum time of tMRD  
must pass before the subsequent command is  
issued.  
The mode register allows configuration of the operat-  
ing mode of the DDR SDRAM. This register is loaded  
as a step in the normal initialization of the device.  
The Load Mode Register command samples the  
values on inputs A0-A11, BA0 (Low) and BA1 (Low)  
and stores them as register values M0-M13. The  
values in the register determine the burst length,  
burst type, CAS latency timing, and DLL Reset/Clear.  
It should be noted that some bit values are reserved  
and should not be loaded into the register. The data  
in the mode register is retained until it is re-loaded or  
the DDR SDRAM loses its power (except for bit M8,  
which is cleared automatically). The register can be  
CAS LATENCY  
After a Read command is issued to the device, a  
latency of several clock cycles is necessary prior to  
the validity of data on the data bus. Also known as  
CAS Latency (CL), the value can be configured as 3,  
4, or 5 depending on the bits M4-M6 loaded into the  
register. Some CL values are not defined for certain  
speed ratings, and if they are used, the device may  
not function properly.  
MODE REGISTER DEFINITION  
Address Bus (Ax)  
BA1 BA0 A11 A10 A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
Mode Register (Mx)  
Burst Length  
M2 M1 M0  
M3=0  
M3=1  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reserved Reserved  
2
4
8
2
4
8
Reserved Reserved  
Reserved Reserved  
Reserved Reserved  
Full Page Reserved  
Burst Type  
M3  
Type  
0
1
Sequential  
Interleaved  
Latency Mode  
M6 M5 M4  
CAS Latency  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reserved  
Reserved  
Reserved  
3
4
5
Reserved  
Reserved  
Operating Mode  
M8 M7 M6-M0 Mode  
0
0
Defined Standard Operation  
1
0
Defined Standard Operation w/DLL Reset  
All Other States Reserved  
Operating Mode  
M13 M12  
M11  
0
M10  
0
M9  
Mode  
0
0
0
Standard operation  
All Other States Reserved  
14  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
BURST LENGTH  
BURST TYPE  
The highest access throughput of this device can be  
achieved by using a burst of either Read or Write  
accesses. The number of accesses in each burst  
would be pre-configured to be 2, 4, 8, or full page as  
shown in Mode Register Definition (bits M0-M2).  
When a Read or Write command is given to the  
device, the address bits A0-A7 (x32) select the block  
of columns and the starting column for the subsequent  
burst. The accesses in this burst can only reference  
the selected block, and may wrap-around if a bound-  
ary is reached. The Burst Definition table indicates  
the relationship between the least significant address  
bits and the starting column. The most significant  
address bits can select any unique block of columns  
in the currently activated row. (Note: Full page bursts  
are possible only in Sequential Mode, with the starting  
address even.)  
Bursts can be made in either of two types: sequential  
or interleaved. The burst type is programmed during a  
Load Mode Register command (bit M3). During a  
Read or Write burst, the order of accesses is deter-  
mined by burst length, starting column, and burst type,  
as indicated in the Burst Definition table.  
DLL RESET/CLEAR  
To cause a DLL reset, the bit M8 is set to 1 in the  
Load Mode Register command. When the DLL is  
reset, 200 clock cycles are required to occur prior to  
any Read operation. To clear the DLL for normal  
operation, the bit M8 is set to 0. This device does not  
require it, but JEDEC specifications require that any  
time that the DLL is reset, it later be cleared prior for  
normal operation.  
BURST DEFINITION  
Burst  
Starting Column  
Address  
Order of Accesses in a Burst  
Length  
Sequential  
Interleaved  
A2  
A1  
A0  
2
4
0
1
0
1
0
1
0
1
0-1  
0-1  
1-0  
1-0  
0
0
1
1
0
0
1
1
0
0
1
1
0-1-2-3  
0-1-2-3  
1-2-3-0  
1-0-3-2  
2-3-0-1  
2-3-0-1  
3-0-1-2  
3-2-1-0  
0
0
0
0
1
1
1
1
0-1-2-3-4-5-6-7  
1-2-3-4-5-6-7-0  
2-3-4-5-6-7-0-1  
3-4-5-6-7-0-1-2  
4-5-6-7-0-1-2-3  
5-6-7-0-1-2-3-4  
6-7-0-1-2-3-4-5  
7-0-1-2-3-4-5-6  
0-1-2-3-4-5-6-7  
1-0-3-2-5-4-7-6  
2-3-0-1-6-7-4-5  
3-2-1-0-7-6-5-4  
4-5-6-7-0-1-2-3  
5-4-7-6-1-0-3-2  
6-7-4-5-2-3-0-1  
7-6-5-4-3-2-1-0  
Not Supported  
0
8
1
0
1
0
1
Full  
Page  
Starting  
address  
Cn, Cn + 1, Cn + 2  
…Cn - 1,  
0
(up to 256) n = A0-A7  
Cn…  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
15  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
EXTENDED MODE REGISTER DEFINITION  
DLL Enable/Disable  
The Extended Mode Register is a second register to  
enable additional functions of the DDR SDRAM. This  
register is loaded as a step in the normal initialization  
of the device. The Load Extended Mode Register  
command samples the values on inputs A0-A11, BA0  
(High) and BA1 (Low) and stores them as register  
values E0-E13. The additional functions are DLL  
enable/disable and output drive strength. Similarly to  
the Load Mode Register, the Load Extended Mode  
Register has reserved bit values, a bank idle pre-  
requisite, and a tMRD time requirement. The data in  
the mode register is retained until it is reloaded or the  
device loses its power.  
When the Load Extended Mode Register command is  
issued, DLL should be enabled (E0 = 0). Normal  
operation of the device requires this, but DLL can be  
disabled for debugging or evaluation, if necessary.  
Output Drive Strength  
Normal drive strength for the outputs is specified as  
SSTL 2. However, there are options for reduced drive  
strength included.  
EXTENDED MODE REGISTER DEFINITION  
Address Bus (Ax)  
Mode Register (Ex)  
BA1 BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0  
Operating Mode  
DLL  
E13 E12 E11 E10 E9  
E8  
0
E7 Mode  
E0  
0
Status  
Enable  
Disable  
0
1
0
0
0
0
Standard Operation  
All Other States Reserved  
1
Drive Strength  
E6  
0
E5  
0
E4  
0
E3  
0
E2  
0
E1  
0
Type  
Full Strength  
0
0
0
0
0
1
Weak-60%  
1
0
0
0
0
1
Matched Impedence  
All Other States Reserved  
16  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
Write  
COMMANDS  
The Write command is used to begin a burst write  
access. When the command is given to the device,  
All commands described in this section should be  
issued only when the initialization sequence is  
obeyed.  
the BA0 and BA1 inputs select the bank, and address  
bits A0-A7 (x32) select the block of columns and the  
starting column for the subsequent burst. The rising  
edge on the Data Strobe input(s) will cause the input  
values on the Data Mask pin(s) and I/O pins to be  
sampled for the write operation. The Auto Pre-charge  
function is one option in the Write command. If the  
Auto Pre-charge is enabled, the currently selected row  
will be Pre-charged following the Write burst. If the  
function is not enabled, the selected row will remain  
open for further accesses at the end of the Write  
burst.  
Deselect  
This feature blocks unwanted commands from being  
executed. Chip select (CS) must be taken High to  
cause Deselect. Operations that are underway are  
not affected.  
No Operation (NOP)  
NOP is a command that prevents new commands from  
being executed. CS must be Low, while RAS, CAS,  
and WE must be High to issue NOP. NOP or Deselect  
commands must be issued during wait states to allow  
operations that are underway to continue uninter-  
rupted.  
Pre-charge  
A Pre-charge command will de-activate an open row in  
a bank. The input A8 (x32) is sampled at this time to  
determine whether Pre-charge is applied to a single  
bank or all banks. After tRP, the bank has been pre-  
charged. It is de-activated, and goes into the idle  
state and must be activated before any Read or Write  
command can be issued to it. A Pre-charge command  
is treated as a NOP if either (a) the specified bank is  
already undergoing Pre-charge, or (b) the specified  
bank has no open row.  
Load Mode Register  
The Base Mode Register is loaded during a step of  
initialization to configure the DDR SDRAM. Load  
Mode Register (LMR) is issued when BA0 and BA1  
are Low, and A0-A11 are selected according to the  
Mode Register Definition.  
Load Extended Mode Register  
The Extended Mode Register is loaded during a step  
of initialization to enable the DLL of the device. Load  
Extended Mode Register (LMR) is issued when BA0 is  
High, BA1 is Low, and A0-A11 are selected according  
to the Extended Mode Register Definition.  
Auto Pre-charge  
Auto Pre-charge is a feature that can be enabled as  
an option in a Read or Write command. If the input  
value on A8 (x32) is High during a Read or Write  
command, an automatic Pre-charge will occur just  
after the memory burst is completed. If the input value  
on A8 (x32) is Low, no Pre-charge will occur. With  
Auto Pre-charge, a minimum time of tRP must pass  
before the next command is issued to the same bank.  
Read  
The Read command is used to begin a burst read  
access. When the command is given to the device,  
the BA0 and BA1 inputs select the bank, and address  
bits A0-A7 (x32) select the block of columns and the  
starting column for the subsequent burst. The cross-  
ing of the CLK and CLK signals will cause the output  
values on the I/O pins to be valid. The Auto Pre-  
charge function is one option in the Read command. If  
the Auto Pre-charge is enabled, the currently selected  
row will be pre-charged following the Read burst. If  
the function is not enabled, the selected row will  
remain open for further accesses at the end of the  
Read burst.  
Active  
The Active command opens a row in preparation for a  
Read or Write burst. The row stays open for accesses  
until the bank receives a Pre-charge command. Other  
rows in the bank cannot be opened until the bank is  
de-activated with a Pre-charge command and another  
Active command is issued.  
Burst Terminate  
The Burst Terminate command truncates the burst of  
the most recently issued Read command (with Auto  
Pre-charge disabled). The open row being accessed  
in the Read burst remains open.  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
17  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
open row will be pre-charged after completion of the  
Read burst. Unless stated otherwise, all timing dia-  
grams for Read operations have disabled Auto Pre-  
charge.  
Auto Refresh  
The DDR SDRAM is issued the Auto Refresh com-  
mand during normal operation to maintain data in the  
memory array. All the banks must be idle for the  
command to be executed. The device has 4096  
refresh cycles every 32ms.  
The Read command causes data to be retrieved and  
placed in the pipeline. The subsequent command can  
be NOP, Read, or Terminate Burst. The data from the  
starting column specified in the Read command  
appears on I/O pins following a CAS latency of after  
the Read command. On each CLK and CLK crossing,  
the data from the next column in the burst sequence is  
output from the pipeline until the burst is completed  
(see Read Burst, Non-consecutive Read Burst, and  
Consecutive Read Burst). There are two cases in  
which a full Read burst length is not completed. The  
first is when the data retrieved from a subsequent  
Read burst interrupts the previous burst (see Random  
Read Accesses). The second is when a subsequent  
Burst Terminate command truncates the burst (see  
Terminating a Read Burst and Read to Write). The  
Burst Terminate and Read commands obey the same  
CAS latency timing such that they should be issued x  
cycles after a previous Read command, where x is the  
number of pairs of columns to output. By following a  
desired command sequence, continuous data can be  
output with either whole Read bursts or truncated  
Read bursts. Whenever a Read burst finishes and no  
other commands have been initiated, the I/O returns to  
High-Z.  
Self Refresh  
To issue the Self Refresh command, CKE must be  
Low. When the DDR SDRAM is in Self Refresh mode,  
it retains the data contents without external clocking,  
and ignores other input signals. The DLL is disabled  
upon entering the Self Refresh mode, and is enabled  
again upon leaving the mode. To exit Self Refresh, all  
inputs must be stable prior to CKE going High. Next,  
a NOP command command must be issued on each  
clock cycle for at least tXSNR to ensure that internal  
refresh operations are completed. To prepare for a  
memory access, the DDR SDRAM must receive a DLL  
reset followed by a NOP command for 200 clock  
cycles.  
DEVICE OPERATION  
Bank and Row Activation  
An Active command must be issued to the DDR  
SDRAM to open a bank and row prior to an access.  
The row will be available for a Read or Write com-  
mand once a time tRCD has occurred. The Active  
command is depicted in the figure. As CLK goes  
High, CS and RAS are Low, while CKE, WE, and CAS  
are High. Upon issuing the Active command, the  
values on the address inputs specify the row, and BA0  
and BA1 specify the bank. When an Active command  
is issued for a bank and row, another row in that same  
bank may be activated after a time tRC. When an  
Active command is issued for a bank and row, a row in  
a different bank may be activated after a time tRRD.  
(Note: to ensure that time requirement tRCD, tRC, or  
tRRD is met, NOP commands should be issued for a  
whole number of clock cycles that is greater than the  
time requirement (ie. tRCD) divided by the clock  
period.)  
If Auto Pre-charge is not enabled in the Read burst,  
the Pre-charge command can be issued separately  
following the Read command. The Pre-charge com-  
mand should be received by the device x cycles after  
the Read command, where x is the desired number of  
pairs of columns to output during the Read burst.  
After the Pre-charge command, it is necessary to wait  
until both tRAS and tRP have been met before issuing  
a new command to the same bank.  
Data Strobe output is driven synchronously with the  
output data on the I/O pins. The Low portion of the  
Data Strobe just prior to the first output data is the  
Read Pre-amble; and the Low portion coinciding with  
the last output data is the Read Post-amble. Before  
any Write command can be executed, any previous  
Read burst must have been completed normally or  
truncated by a Burst Terminate command. In the  
diagram Read to Write, a Burst Terminate command is  
issued to truncate a Read Burst early, and begin a  
Write operation. After the Write command, a time  
tDQSS is required prior to latching the data on the I/O.  
Read Operation  
A Read command starts a burst from an activated row.  
The Read command is depicted in the figure. As CLK  
goes High, CS and CAS are Low, while RAS, CKE,  
and WE are High. The values on the inputs BA0 and  
BA1 specify the bank to access, and the address  
inputs specify the starting column in the open row. If  
Auto Pre-charge is enabled in the Read command, the  
18  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
truncating the input data, the timing parameter tWR  
should be obeyed before issuing the Pre-charge  
command (see Write to Pre-charge, Non-truncated).  
Write Operation  
A Write command starts a burst from an activated row.  
The Write command is depicted in the figure. As CLK  
goes High, CS, WE, and CAS are Low, while CKE and  
RAS are High. The values on the inputs BA0 and BA1  
specify the bank to access, and the address inputs  
specify the starting column in the open row. If Auto  
Pre-charge is enabled in the Write command, the  
open row will be pre-charged after completion of the  
Write burst and time tWR. Unless stated otherwise, all  
timing diagrams for Write operations have disabled  
Auto Pre-charge.  
The period tWR begins on the first positive clock edge  
after the last data input has been latched. The Write  
burst can be truncated deliberately by using the Data  
Mask feature and a Pre-charge command with an  
earlier timing (see Write to Pre-charge, Truncated).  
After the Pre-charge command, it is necessary to wait  
until tRP has been met before issuing a new command  
to the same bank.  
Power Down Operation  
The Write command in conjunction with Data Strobe  
inputs causes data to be latched and placed in the  
pipeline. The Low portion of the Data Strobe between  
the Write command and the first rising edge of the  
strobe is the Write Pre-amble; and the Low portion  
following the last input data is the Write Post-amble.  
A minimum time of tDQSS after the Write, the next  
command can be NOP or Write. The data that is to be  
written to the starting column specified in the Write  
command will be latched upon the first rising edge of  
Data Strobe input(s) DQS0-DQS3 (x32) after that  
Write command. On each Data Strobe transition from  
Low-to-High or High-to-Low, the input values on the I/  
O are sampled, and enter pipeline to be written in the  
pre-determined burst sequence (see Write Burst,  
Consecutive Write to Write, and Non-consecutive  
Write to Write). A new Write command can be issued  
x cycles after a previous Write command, where x is  
the number of pairs of columns to input. By following a  
desired command sequence, continuous data can be  
input with either whole Write bursts or truncated Write  
bursts. Whenever a Write burst finishes and no other  
commands have been initiated, the I/O returns to  
High-Z.  
When the DDR SDRAM enters Power Down mode,  
power consumption is greatly reduced. To enter the  
mode, several conditions must be met. There must be  
neither a Read operation, nor a Write operation  
underway in the device at CLK positive edge n – 1,  
with CKE stable High. Prior to CLK positive edge n,  
CKE should go Low. A Power Down mode is entered  
if the appropriate command is issued as CLK n goes  
High. (If the command at CLK n is Auto Refresh, the  
SDRAM enters Self Refresh mode.) If the command at  
CLK n is NOP or Deselect, the device will enter Pre-  
charge Power Down mode or Active Power Down  
mode. While in a Power Down mode, CKE must be  
stable Low, and CLK and CLK signals maintained,  
while other inputs are ignored. Pre-charge Power  
Down mode conserves additional power by freezing  
the DLL. To exit the Power Down mode, normal  
voltages and clock frequency are applied. Prior to  
CLK positive edge n, CKE should go High. A NOP or  
Deselect command at CLK n, allows a valid command  
to be issued at CLK positive edge n + 1. (If exiting  
Self Refresh mode, the DLL is automatically enabled,  
and the device must be prepared according to the  
section describing Self Refresh.)  
A Write burst may be followed by Read command, with  
or without truncating the Write burst. To avoid truncat-  
ing the input data, the timing parameter tWTR should  
be obeyed before issuing the Read command (see  
Write to Read, Non-truncated). The period tWTR  
begins on the first positive clock edge after the last  
data input has been latched. The Write burst can be  
truncated deliberately by using the Data Mask feature  
and a Read command with an earlier timing (see Write  
to Read, Truncated).  
Pre-charge Operation  
When this command is issued, either a particular  
bank, or all four banks will be de-activated after a time  
period of tRP. The bank(s) will be available for a row  
access until that time has occurred. The Pre-charge  
command is depicted in the figure. As CLK goes  
High, CS, RAS, and WE are Low, while CKE and CAS  
are High. The values on the address inputs are Don’t  
Care, except for the input A8 (x32), which determines  
whether a single bank is selected for Pre-charge, or  
all four banks. If A8 is Low, the inputs BA0 and BA1  
select the single bank; however, if A8 is High, BA0  
and BA1 are Don’t Care. Once any bank has been  
pre-charged, it becomes idle. Before any row can  
have a Read or Write access, it must be activated.  
If Auto Pre-charge is not enabled in the Write burst,  
the Pre-charge command can be issued separately  
some time following the Write command. The proce-  
dure to execute it is similar to the procedure to transi-  
tion from a Write burst to a Read burst. To avoid  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
19  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
Timing Waveforms  
Figure 1. AC Parameters for Read Timing ( Burst Length =4)  
Figure 2. AC Parameters for Write Timing (Burst Length=4 )  
CK#  
CK  
CMD  
A0-11,  
DQS  
DM  
DQ  
20  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
21  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
Figure 6. Write with Auto Precharge (Burst Length = 4)  
Figure 7. Read Burst Interrupt by Read (CAS Letancy =5, Burst Length = 4 )  
Figure 8. Write Interrupted by Write (Burst Length =4)  
Figure 9. Auto Refresh Timing  
22  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
Figure 11. Precharge Command  
tMRD  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
23  
Rev. 00D  
02/15/06  
®
IS43R32400A  
ISSI  
ORDERING INFORMATION  
Commercial Range: 0°C to +70°C  
Frequency  
Speed(ns)  
Order Part No.  
Package  
200 MHz  
200 MHz  
5
5
IS43R32400A-5B  
IS43R32400A-5BL  
144-ballFBGA  
144-ballFBGA,Lead-free  
166 MHz  
166 MHz  
6
6
IS43R32400A-6B  
IS43R32400A-6BL  
144-ballFBGA  
144-ballFBGA,Lead-free  
Industrial Range: -40°C to +85°C  
Frequency  
Speed(ns)  
Order Part No.  
Package  
166 MHz  
166 MHz  
6
6
IS43R32400A-6BI  
IS43R32400A-6BLI  
144-ballFBGA  
144-ballFBGA,Lead-free  
24  
Integrated Silicon Solution, Inc. — 1-800-379-4774  
Rev. 00D  
02/15/06  
®
PACKAGING INFORMATION  
ISSI  
Mini Ball Grid Array  
Package Code: B (144-Ball)  
ø 0.45 +/− 0.05 (144X)  
12 11 10 9 8 7 6 5 4 3 2 1  
1
2 3 4 5 6 7 8 9 10 11 12  
A
B
C
D
E
F
A
B
C
D
E
F
e
G
H
J
G
H
J
D1  
K
L
D
K
L
M
M
e
E1  
E
A1  
A
Notes:  
1. Controlling dimensions are in millimeters.  
2. 0.8 mm Ball Pitch  
SEATING PLANE  
mBGA - 12mm x 12mm  
MILLIMETERS  
INCHES  
Sym. Min. Typ. Max.  
Min.  
Typ. Max.  
N0.  
Leads  
144  
A
1.17  
0.32  
1.25 1.40  
0.35 0.38  
0.046  
0.013  
0.049 0.055  
0.014 0.015  
A1  
D
11.95 12.00 12.05  
8.80  
11.95 12.00 12.05  
0.470 0.472 0.474  
0.346  
0.470 0.472 0.474  
D1  
E
E1  
e
8.80  
0.80  
0.346  
0.031  
Copyright © 2005 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time  
without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to  
obtain the latest version of this device specification before relying on any published information and before placing orders for products.  
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774  
Rev. A  
05/23/05  

相关型号:

IS43R32400A-6BI

4Meg x 32 128-MBIT DDR SDRAM
ISSI

IS43R32400A-6BL

4Meg x 32 128-MBIT DDR SDRAM
ISSI

IS43R32400A-6BLI

4Meg x 32 128-MBIT DDR SDRAM
ISSI

IS43R32400D

Four internal banks for concurrent operation
ISSI

IS43R32400D-4BL

Four internal banks for concurrent operation
ISSI

IS43R32400D-4BLI

Four internal banks for concurrent operation
ISSI

IS43R32400D-5BL

Four internal banks for concurrent operation
ISSI

IS43R32400D-5BLI

Four internal banks for concurrent operation
ISSI

IS43R32400D-6BL

Four internal banks for concurrent operation
ISSI