CGE High Power Connectors  
HS-5/1199  
CGE  
The contacts made of copper or a copper  
alloy with hard silver finish are designed  
for crimping or termination to solid copper  
conductors with threaded bolts. The  
mechanical durability is a minimum of 500  
mating cycles. The crimp contacts accept  
wires according to DIN 46438 (25 – 240  
mm2). Contact retention is achieved by the  
two-piece insulator which is fixed to the  
shell with a snap-in ring. This allows  
unlimited exchange of the crimp contacts.  
Contents  
Introduction  
Introduction .......................................... 2  
Connector Design ..............................  
The Cannon CGE connectors are designed  
to transm it very high current at low  
voltage, as for example in the electrical  
equipment of military land- and sea-borne  
vehicles and in industrial applications. The  
connectors meet the mating dimensions,  
m ech an ical feat u res an d rear p an el  
installation requirements of VG 95234.  
Ultraflexible shielded welding cables acc  
to MTV 6145-005 are terminated to the  
connectors.  
2
How to order ....................................... 3  
Mateability ......................................... 3  
Polarization ........................................... 3  
Technical Data ...................................... 4  
Panel Cut-Outs ..................................... 5  
Connector Dimensions .......................... 6  
Accessories ........................................... 9  
Contacts and Tools ............................... 10  
Product Safety Information .................. 11  
The bayonet coupling assures fast and  
reliable mating and unmating. Audible  
snap-in and colour-coded snap-in points  
in d icat e p o sit ive m at in g . Plug s an d  
receptacles are waterproof in m ated  
condition up to 1 bar (35 feet of water).  
Connector Design  
The high power connectors CGE feature  
one contact in a two-piece rigid insulator.  
The aluminum shell has a chromate finish  
over cadmium. The operating temperature  
ranges from –55 to 125°C.  
O-Ring  
Shell  
Insulator Cylindrical O-Ring  
Insulator  
Contact  
rear side  
Spring ring  
Connector Design  
Contact  
Contact  
front side  
Spring ring Insulator  
Contact  
O-Ring  
contact  
Spring  
Insulator  
Contact  
Barrel assembly  
rear side  
front side  
Dimensions are mm (inches)  
Subject to changes  
2
CGE  
CGE 6 E 32 H 24 F W B *  
Polarization  
How to order  
To avoid mismating of identic connectors  
the keyways of CGE connectors are avail-  
able in two different positions:  
Series  
Cannon Designation  
Shell style  
Standard position  
Position W  
= 180°  
= 120°  
0 - wall mounting receptacle with flange  
1 - cable connecting plug  
2 - box mounting receptacle with flange  
6 - straight plug  
8 - plug 90°  
9 - bulkhead  
Class  
E - environmental, JP07 acc to DIN 40050  
Shell size  
16 - 18 - 22 - 28 - 32  
Contact arrangem ent  
16H2 - shell size 16, 1 contact H2  
18H5 - shell size 18, 1 contact H5  
22H9 - shell size 22, 1 contact H9  
28H15 - shell size 28, 1 contact H15  
32H24 - shell size 32, 1 contact H24  
Contact size  
H2 - 25 mm2  
H5 - 50 mm2  
H15 - 150 mm2  
H24 - 240 mm2  
Keyway positions of receptacles  
and cable connecting plugs  
Contact type  
F - spring contact  
Z - cylindrical contact  
Keyway polarization  
W - 120°  
Bayonet coupling  
Modification  
05 - through-holes in flange  
03 - adapter for heat shrink boots, metric crimp contact  
04 - rear panel mounting, threaded holes, metric crimp contact  
04-05 - same as -04, however, with through-holes  
14 - shielded version, metric crimp contact  
16 - thread bolt termination, front panel mounting, O ring for sealing  
between wall and receptacle (for CGE2EB only)  
Mateability  
Keyway positions of straight and 90°plugs  
Receptacles and cable connecting plugs mate with  
CGE2E-B04, CGE-B-04-05  
CGE2E-B-16  
à
Plugs, straight / 90°  
CGE6E-B-03  
CGE6E-B-14  
CGE0E-B-03, CGE-B-05-05  
CGE1E-B-03  
CGE8E-B-03  
CGE8E-B-14  
3
CGE  
Technical Data  
Electrical Data  
Adm issible am bient tem perature  
Current rating  
–55/125°C  
(A) at 125°C ambient temperature  
Class  
Shell size  
Contact size  
Max Current rating (A) 225  
Max Short-time load,  
16  
H2  
18  
H5  
350  
22  
H9  
570  
28  
H15  
750  
32  
H24  
950  
JP07 acc to DIN 40050  
Test pressure  
1 bar overpressure  
appr 0,5 – 1 sec (A)  
750  
1000  
2000  
3000  
5000  
Test duration  
12 h  
Air and creepage paths  
Air path  
Creepage path  
Insulator resistance  
min 5000 MOhm  
3 mm min  
5 mm min  
Vibration  
200 m/s2 for 10 – 2000 Hz  
Mechanical durability  
500 mating cycles  
Contact resistance  
(mOhm max)  
Coupling torque  
in wired condition acc to VG95319, Part  
2, Test No 5.8.2.  
Shell size  
max closing / max opening  
opening Nm  
5,5  
8,0  
11,0  
17,0  
Nm  
0,5  
0,6  
0,8  
0,9  
1,0  
16  
18  
22  
28  
32  
19,0  
Contact size  
Contact resistance 0,6  
H2  
H5  
0,3  
H9  
0,15  
H15  
0,1  
H24  
0,07  
Contact retention  
acc to VG 95319, Part 2, Test No 5.4.  
Contact size  
H2  
H5  
H9  
H15  
H24  
Test force N min  
Cables  
100  
120  
140  
160  
200  
The connectors are designed for ultraflexible welding cable acc to MTV 6145-005.  
Shell size  
Wire size  
MTV 6145-005 designation  
shielded  
unshielded  
16  
18  
22  
28  
32  
25  
50  
95  
150  
240  
MTV 6145-005 H001  
MTV 6145-005 H002  
MTV 6145-005 H003  
MTV 6145-005 H004  
MTV 6145-005 H005  
MTV 6145-005 G001  
MTV 6145-005 G002  
MTV 6145-005 G003  
MTV 6145-005 G004  
MTV 6145-005 G005  
Materials  
Shell  
– Finish  
Aluminum alloy  
Olive chromate over  
cadmium  
When selecting a cable type please consider self-heating of cable at the maximum  
operating voltage and the maximum ambient temperature (see page 5).  
Insulator  
Contact  
– Finish  
O ring  
PTFE  
Copper or copper alloy  
Hard silver  
FKM  
Dimensions are mm (inches)  
Subject to changes  
4
CGE  
Cable Data  
Approx. values for cable self-heating  
Wire size  
mm2  
Max admissible  
operating voltage  
Approx over-temperature due to current load: T in °C  
1/3 of max admissible  
2/2 of max admissible max admissible  
operating voltage  
operating voltage  
operating voltage  
25  
50  
95  
150  
240  
250  
300  
500  
600  
1000  
35  
15  
10  
5
52  
25  
33  
23  
30  
95  
55  
70  
60  
75  
8
Cable Dim ensions  
Outer jacket  
Shielding braid, tinned  
Inner jacked  
Copper conductor  
Cable designation  
Shell  
Wire size  
mm2  
25  
50  
95  
Straight plug  
Plug 90°  
e2  
-
-
20,0  
25,0  
25,0  
+ /–1,0  
size  
16  
18  
22  
28  
32  
a
b max  
13,5  
c max  
10,2  
14,3  
19,7  
25,4  
32,5  
d+ /–10,5  
e1 + /–1,0  
31,0  
31,0  
42,0  
-
f1 + /–1,0  
f2 + /–1,0  
-
-
35,0  
40,0  
40,0  
MTV6145-005+ 001  
MTV6145-005+ 001  
MTV6145-005+ 001  
MTV6145-005+ 001  
MTV6145-005+ 001  
7,5+ /–0,5  
14,0  
15,0  
20,5  
30,0  
30,0  
46,0  
46,0  
57,0  
-
11,0+ /–0,5 18,0  
16,0+ /–0,5 23,5  
20,5+ /–0,5 30,0  
26,5+ /–0,5 36,0  
150  
240  
54,0  
69,0  
Panel Cut-Outs  
Panel cut-outs for rear and front panel  
mounting of receptacles  
Shell size  
Receptacles, rear panel mounting  
Receptacles, front panel mounting  
CGE2E-B-16  
CGE0E-B-03/14  
CGE2E-B-04  
H13  
H12  
d
H13  
c
H12  
thread  
M4  
+ 0,15  
+ 0,15  
± 0,15  
± 0,15  
c
d
d
c
16  
18  
22  
28  
32  
4,5  
4,5  
4,5  
5,5  
5,5  
27,7  
31,1  
37,8  
47,1  
53,8  
24,6  
27,0  
31,8  
39,7  
44,5  
4,5  
4,5  
4,5  
4,5  
4,5  
22,5  
27,4  
33,7  
43,5  
49,7  
24,6  
27,0  
31,8  
39,7  
44,5  
M4  
M4  
M4  
M4  
5
CGE  
CGE0E...B-03  
Wall m ounting receptacle,  
acc to VG 96929B1,  
rear panel mounting,  
four threaded holes in flange,  
adapter for heat shrink boot,  
metric crimp contacts  
Shell  
size  
16  
22  
32  
a
d1  
d2  
d3  
e
g
h
l1  
l4  
l5  
l6  
– 0,15  
27,4  
37,4  
53,4  
± 0,15  
20,0  
45,8  
45,8  
± 0,3  
22,1  
49,2  
49,2  
± 0,1  
24,6  
31,8  
44,5  
± 0,1  
3,2  
3,2  
3,5  
± 0,2  
12,0  
20,8  
28,0  
± 0,3  
41,0  
55,0  
66,8  
± 0,3  
20,0  
23,15  
29,0  
± 0,15  
3,2  
4,0  
± 0,3  
32,5  
41,0  
57,0  
M4  
M4  
M5  
4,0  
CGE1E...B-03  
Cable connecting plug, straigt,  
adapter for heat shrink boots,  
metric crimp contacts  
Shell size  
a
d1  
d2  
g
h
l1  
– 0,15  
30,8  
37,4  
53,4  
46,7  
± 0,15  
25,0  
31,5  
45,8  
41,0  
± 0,15  
± 0,1  
3,2  
3,2  
3,5  
3,5  
± 0,15  
20,0  
20,5  
28,0  
25,0  
± 0,3  
18  
22  
28  
32  
27,0  
34,9  
50,0  
44,4  
50,0  
54,0  
66,8  
65,8  
CGE1E...B-14  
Cable connecting plug,  
shielded version,  
metric crimp contacts  
Shell size  
18  
a
b
c
d
g
h
max  
48,5  
l1  
max  
95,5  
SW1  
34  
SW2  
38  
± 0,15  
37,4  
± 0,3  
25,5  
± 0,2  
22,5  
42,0  
37,0  
Dimensions are mm (inches)  
Subject to changes  
6
CGE  
CGE2E...B-04  
CGE2E...B-04-05  
Box m ounting receptacle,  
rear panel mounting,  
-04 – four threaded holes in flange,  
-04-05 – four through holes in flange  
Shell size  
a
d1  
d
e
h
l1  
l2  
n
– 0,15  
27,4  
30,8  
37,4  
46,6  
53,4  
± 0,15  
22,1  
27,0  
34,9  
42,7  
49,2  
Mod 04  
M4  
M4  
M4  
M4  
Mod 05  
4,3  
4,3  
4,3  
4,3  
± 0,1  
24,6  
27,0  
31,8  
39,7  
44,5  
± 0,2  
20,0  
23,15  
23,15  
-
± 0,3  
41,0  
50,0  
54,0  
65,3  
66,8  
± 0,3  
32,5  
35,0  
41,0  
50,8  
57,0  
± 0,1  
3,2  
4,0  
4,0  
4,0  
4,0  
16  
18  
22  
28  
32  
M5  
5,3  
29,0  
CGE2E...B-16  
Box m ounting receptacle,  
front panel mounting,  
four through holes in flange,  
threaded bolt termination for  
solid copper rail  
Shell  
size  
18  
22  
28  
a
d1  
d2  
d
e
g
h
l1  
l2  
l5  
l7  
n
SW  
– 0,15  
30,8  
37,4  
46,6  
53,4  
– 0,15 + 0,2  
± 0,1  
27,0  
31,8  
39,7  
44,5  
± 0,3  
4,0  
4,4  
4,0  
6,0  
max  
55,0  
65,5  
61,0  
73,0  
± 0,3  
23,15  
23,15  
24,15  
29,0  
± 0,5  
+ 0,3  
35,0  
41,0  
50,8  
57,0  
± 0,15  
4,0  
4,0  
4,0  
4,0  
M8  
26,9  
33,2  
42,8  
49,2  
4,3  
4,3  
4,3  
4,3  
27,5  
38,0  
32,0  
44,5  
15,0  
25,3  
20,0  
22,0  
3
6
6
8
M12  
M12  
M16  
32  
CGE6E...B-03  
Straight plug  
acc to VG 96929A2,  
adapter for heat shrink boots,  
metric crimp contacts  
Shell size  
d1  
d2  
d3  
g
h
l1  
max  
32,0  
36,5  
43,1  
60,1  
– 0,1  
20,2  
25,8  
31,5  
45,4  
max  
22,3  
28,0  
35,0  
49,2  
± 0,2  
27,0  
31,8  
39,7  
44,5  
max  
44,0  
53,0  
57,0  
65,0  
16  
18  
22  
32  
4,3  
4,3  
4,3  
4,3  
7
CGE  
CGE6E...B-14  
Straight plug  
acc to VG 96929F,  
360° HF shielding by grounding fingers,  
endbells for clamp connection of shielding  
braid and for heat shrink boots,  
metric crimp contacts  
Shell size  
c
d1  
d2  
d4  
g
h
l1  
SW  
± 0,3  
26,0  
32,0  
37,0  
44,0  
31,0  
max  
32,0  
36,5  
43,1  
53,0  
60,1  
± 0,15  
24,0  
28,7  
33,7  
40,0  
47,2  
± 0,1  
15,5  
20,0  
25,5  
32,0  
38,0  
± 0,1  
1,0  
1,0  
1,0  
1,0  
1,0  
± 0,4  
25,5  
26,0  
26,0  
26,0  
28,0  
max  
68,0  
73,5  
84,0  
98,0  
95,5  
16  
18  
22  
28  
32  
26  
32  
38  
50  
54  
CGE8E...B-03  
90° plug  
with adapter for heat shrink boots,  
metric crimp contacts  
CGE8E...B-14  
90° plug  
acc to VG 96929E,  
with grounding fingers, adapter for  
shielding braid and for use with heat  
shrink boots, metric crimp contacts  
Shell size  
d1  
d3  
max  
42,0  
48,0  
52,5  
l1  
l3  
max  
41  
41  
41  
l4  
max  
56  
56  
56  
l6  
l
SW  
max  
43,1  
53,0  
60,1  
± 1,0  
80,0  
78,0  
84,0  
± 0,2  
3,2  
3,2  
max  
22  
28  
32  
101,0  
102,0  
112,0  
38  
50  
52  
3,2  
CGE9E...X-B-04  
Bulkhead  
acc to VG 96929C2,  
with through holes in flange  
Shell size  
a
d1  
e
l1  
l2  
l3  
l4  
– 0,15  
46,7  
± 0,1  
39,7  
max  
51,5  
± 0,3  
20,6  
± 0,1  
4,0  
± 0,3  
50,8  
22  
5,3  
Dimensions are mm (inches)  
Subject to changes  
8
CGE  
Accessories  
Dust cap 121004  
for plugs  
Order reference  
Size  
a
b
c
d
+ 0,5  
4,3  
4,3  
4,3  
4,3  
5,5  
± 10,0  
113  
127  
140  
197  
197  
max  
29,0  
30,0  
30,0  
30,0  
30,0  
max  
29,9  
33,3  
39,9  
49,2  
55,9  
CA121004-4  
CA121004-6  
CA121004-8  
CA121004-10  
CA121004-11  
16S  
18  
22  
28  
32  
Dust cap 121003  
for receptacles  
Order reference  
Size  
a
b
c
d
+ 0,5  
4,3  
4,3  
4,3  
5,5  
± 10,0  
100  
113  
127  
169  
169  
max  
19,5  
25,4  
25,4  
25,4  
25,4  
max  
32,6  
36,7  
43,3  
52,6  
59,3  
CA121003-4  
CA12100436  
CA121003-8  
CA121003-10  
CA121004311  
16S  
18  
22  
28  
32  
5,5  
Dum m y receptacle  
Order ref.  
Size  
a
b
d
d1  
e
f
g
h
± 0,3  
32,5  
35,0  
41,0  
50,8  
57,0  
± 0,15  
24,6  
27,0  
31,8  
39,7  
44,5  
+ 0,2  
3,2  
3,2  
3,2  
3,7  
4,4  
± 0,2  
21,5  
27,2  
27,2  
28,2  
28,2  
+ 0,3 / – 0,1 + 0,1  
+ 0,15  
27,4  
30,8  
37,4  
46,7  
53,4  
248-8504-000  
248-8506-000  
248-8508-000  
248-8510-000  
248-8511-000  
16S  
18  
22  
28  
32  
M4  
M4  
M4  
M5  
M5  
18,3  
29,6  
23,8  
30,0  
38,8  
45,2  
23,15  
23,15  
24,15  
24,15  
9
CGE  
Contacts  
Order references for single contacts  
Accessories  
Shell size  
H24  
Spring contact  
031-8564-000  
031-8567-000  
031-8658-000  
031-8663-000  
031-8669-000  
031-8701-004  
031-8649-000  
031-8660-000  
031-8659-000  
031-8655-000  
031-8656-000  
031-8616-000  
Cylindrical contact  
330-8697-000  
330-8696-000  
031-8701-002  
330-8719-000  
031-8701-000  
430-8561-009  
330-8698-000  
330-8695-000  
031-8701-000  
330-8710-000  
330-8712-000  
330-8623-000  
031-8705-000  
Contact type  
Crimp with  
Crimp sleeve  
Sealing gaskets  
for rear panel mounting only  
threaded bolt  
for 90° plug  
with threaded bolt  
for 90° plug  
Crimp version  
Crimp with  
threaded bolt  
for 90° plug  
crimp with  
252-8583-000  
252-8583-000  
Shell  
size  
Order references Order references  
Polychloroprene  
H15  
H9  
Alu-Flex  
(shielded version)  
075-8504-001  
075-8505-001  
075-8507-001  
075-8509-001  
075-8510-001  
16  
18  
22  
28  
32  
075-8504-000  
075-8505-000  
075-8507-000  
075-8509-000  
075-8510-000  
252-8583-000  
H5  
threaded bolt  
crimp version  
for bulkhead  
H2  
H9  
O Rings  
for sealing of front mounting receptacles  
are included in shipment  
Note: When choosing the contacts please make sure that the voltage carrying side of the connection  
is quipped with the cylindrical contact.  
Description  
Designation  
Order reference  
121586-0027  
121586-0008  
121586-0023  
121586-0031  
121086-3079  
Crimp Tools  
1
2
3
4
5
6
Hand pump  
4601.00000.330  
4601.51000.330  
4604.00000.020  
4632.00000.601  
CT121086-3079  
Foot operation for hand pump  
High pressure hose, length 2 m  
Crimp head  
Safety device incl. bench mounting  
Positioner (to be used with  
121086-3079 only)  
CT121086-3080  
121086-3080  
Right hand photograph:  
Electro-hydraulic crimp tool HK12EL.  
Available upon request please consult  
factory  
Crim p dies  
Special Allen Wrenches  
for endbell assembly  
Contact Order reference  
size  
H2  
H5  
H9  
H15  
H24  
upper crimp dies lower crimp dies  
Shell size  
Order reference  
CGE-SW26  
CGE-SW26  
CGE-SW26  
CGE-SW26  
317-8578-006  
317-8578-008  
317-8578-004  
317-8578-002  
317-8578-000  
317-8578-007  
317-8578-009  
317-8578-005  
317-8578-003  
317-8578-001  
16  
18  
22  
28  
Dimensions are mm (inches)  
Subject to changes  
10  
CGE  
Product safety Information  
THIS NOTE SHOULD BE READ IN CONJUNCTION  
WITH THE PRODUCT DATA SHEET/CATALOGUE.  
FAILURE TO OBSERVE THE ADVICE IN THIS INFOR-  
MATION SHEET AND THE OPERATING CONDITIONS  
SPECIFIED IN THE PRODUCT DATA SHEET/  
CATALOGUE COULD RESULT IN HAZARDOUS  
SITUATIONS.  
3. HANDLING  
Always use the correct application tools as specified  
in the Data Sheet/Catalogue.  
Care must be taken to avoid damage to any  
component parts of electrical connectors during  
installation and use. Although there are normally  
no sharp edges, care must be taken when handling  
certain components to avoid injury to fingers.  
Electrical connectors may be damaged in transit to  
the customers, and damage may result in creation  
of hazards. Products should therefore be examined  
prior to installation/use and rejected if found to be  
damaged.  
Do not permit untrained personnel to wire, assemble  
or tramper with connectors.  
For operation voltage please see appropriate national  
regulations.  
1. MATERIAL CONTENT AND PHYSICAL  
FORM  
Electrical connectors do not usually contain  
hazardous materials. They contain conducting and  
non-conducting materials and can be divided into  
two groups.  
IMPORTANT GENERAL INFORMATION.  
1. Air and creepage paths/Operating voltage  
The admissible operating voltages depend on the  
individual applications and the valid national and  
other applicable safety regulations.  
4. DISPOSAL  
Incineration of certain materials may release  
noxious or even toxic fumes.  
a) Printed circuit types and low cost audio types  
which employ all plastic insulators and casings.  
5. APPLICATION  
For this reason the air and creepage path data  
are only reference values. Observe reduction of air  
and creepage paths due to PC board and/or harness-  
ing.  
Connectors with exposed contacts should not be  
selected for use on the current supply side of an  
electrical circuit, because an electric shock could  
result from touching exposed contacts on an  
unmated connector. Voltages in excess of 30 V ac  
or 42.5 V dc are potentially hazardous and care  
should be taken to ensure that such voltages can  
not be transmitted in any way to exposed metal parts  
of the connector body. The connector and wiring  
should be checked, before making live, to have no  
damage to metal parts or insulators, no solder blobs,  
loose strands, conducting lubricants, swarf, or any  
other undesired conducting particles. Insulation  
resistance should be checked to make certain that  
no low resistance joints or spurious conducting path  
are existing between contacts and exposed metal  
parts of the connector body. Further the contact  
resistance of the connectors should be measured  
within the electrical circuit in order to identify high  
resistances which result in excessive connector  
heating.  
b) Rugged, Fire Barrier and High Reliability types  
with metal casings and either natural rubber,  
synthetic rubber, plastic or glass insulating  
materials.  
2. Temperature  
All information given are temperature limits. The  
operation temperature depends on the individual  
application.  
Contact materials vary with type of connector and  
also application and are usually manufactured from  
either copper, copper alloys, nickel, alumel, chromel  
or steel. In special applications, other alloys may  
be specified.  
3. Other important information  
Cannon continuously endeavours to improve their  
products. Therefore, Cannon products may deviate  
from the description, technical data and shape as  
shown in this catalogue and data sheets.  
2. FIRE CHARACTERISTICS AND ELECTRIC  
SHOCK HAZARD  
There is no fire hazard when the connector is  
correctly wired and used within the specified  
parameters. Incorrect wiring or assembly of the  
connector or careless use of metal tools or  
conductive fluids, or transit damage to any of the  
component parts may cause electric shock or  
burns. Live circuits must not be broken by sepa-  
rating mated connectors as this may cause arcing,  
ionisation and burning.  
4. Harnessing and Assembly Instructions  
If applicable, our special harnessing and/or assem-  
bly instruction has to be adhered to. This is provid-  
ed at request.  
Heat dissipation is greater at maximum resistance  
in a circuit. Hot spots may occur when resistance  
is raised locally by damage, e.g. cracked or  
deformed contacts, broken strands of wire. Local  
overheating may also result from the use of the  
incorrect application tools or from poor quality  
soldering or slack screw terminals. Overheating may  
occur if the ratings in the Product Data Sheet/  
Catalogue are exceeded and can cause breakdown  
of insulation and hence electric shock.  
If heating is allowed to continue it intensifies by  
further increasing the local resistance through loss  
of temper of spring contacts, formation of oxide  
film on contacts and wires, and leakage currents  
through carbonisation of insulation and tracking  
paths. Fire can then result in the presence of  
combustible materials and this may release noxious  
fumes. Overheating may not be visually apparent.  
Burns may result from touching overheated  
components.  
ITT Cannon manufactures the highest quality products available in the marketplace; however these products are intended  
to be used in accordance with the specifications in this catalog. Any use or application that deviates from stated operating  
specifications is not recommended and may be unsafe. No information and data contained in this catalog shall be construed  
to create any liability on the part of Cannon. Any new issue of this catalog shall automatically invalidate and supersede  
any and all previous issues. A limited warranty applies to Cannon products. Except for obligations assumed by Cannon  
under this warranty, Cannon shall not be liable for any loss, damage, cost of repairs, incidental or consequential  
damages of any kind, whether or not based on express or implied warranty, contract, negligence or strict liability  
arising in connection with the design, manufacture, sale, use or repair of the products. Product availability, prices and  
delivery dates are exclusively subject to our respective order confirmation form; the same applies to orders based on  
development samples delivered. This catalog is not be construed as an offer. It is intended merely as an invitation to make  
an offer. By this publication, Cannon does not assume responsibility or any liability for any patent infringements or other  
rights of third parties which may result from its use. Reprinting this catalog is generally permitted, indicating the source.  
However, Cannon's prior consent must be obtained in all cases.  
Cannon is a trademark of ITT Industries, Inc  
11  

相关型号:

CGE1E1818H5H24FWB05

High Power Connectors
ITT

CGE1E1818H5H2FWB03

High Power Connectors
ITT

CGE1E1818H5H2FWB05

High Power Connectors
ITT

CGE1E1818H5H5FWB03

High Power Connectors
ITT

CGE1E1818H5H5FWB05

High Power Connectors
ITT

CGE1E1822H9H15FWB03

High Power Connectors
ITT

CGE1E1822H9H15FWB05

High Power Connectors
ITT

CGE1E1822H9H24FWB03

High Power Connectors
ITT

CGE1E1822H9H24FWB05

High Power Connectors
ITT

CGE1E1822H9H2FWB03

High Power Connectors
ITT

CGE1E1822H9H2FWB05

High Power Connectors
ITT

CGE1E1822H9H5FWB03

High Power Connectors
ITT