EK21HRA [IVO]

Ceramic Sensor, Absolute, Round;
EK21HRA
型号: EK21HRA
厂家: BAUMER IVO GMBH & CO. KG    BAUMER IVO GMBH & CO. KG
描述:

Ceramic Sensor, Absolute, Round

文件: 总4页 (文件大小:220K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
EK-ED-EP-ER-ET-EC-EL Pressure Sensors  
Measurement of gauge or absolute pressure  
From 250 mbar to 600 bar full scale  
Corrosion resistant  
Excellent long term stability  
Low cost - excellent performances / price ratio  
TheTRANSBAR® technology is a spin off of the «thick film technology» used worldwide  
to produce so called «hybrid electronic circuits».  
Patterns of conductive and resistive pasts, or «inks», are deposited on a substrate,  
generally ceramics, using screen printing techniques.  
The uniqueness of the «TRANSBAR®» technology is to use the piezoresistive charac-  
teristics of specific resistive inks, i.e. the fact that their resistance values vary when  
submitted to dimensional changes.  
These resistors, called strain gauges, judiciously positionned on the deformable  
structure (diaphragm), are connected together in a four arms Wheatstone bridge  
configuration.  
A regulated voltage source is connected to one diagonal of the bridge.  
A pressure applied to the diaphragm will deform it and therefore unbalance the bridge,  
resulting in an electrical signal, on the other diagonal of the bridge, proportional to  
the applied pressure.  
This low level signal, some mV., will have to be amplified to a suitable level to be connected to a display, controller, recorder, PLC or whatever required peripheric equipment.  
Constructed entirely of ceramics (Al203, 96 %), comparable to a cristal, these sensors have a quasi perfect mechanical behaviour : good linearity, low hysteresis. They can  
withstand tens of millions of cycles. Chemically inert, ceramics accepts most industrial media, even aggressive ones.  
Their simple geometry allows their easy integration in OEM’s mechanical structures.  
The field of their applications is very wide, from basic research to general industry.  
Models  
EK (CS) : Open bridge, unbalanced.  
Bridge impedance :15 k+30%  
ED (CA) : Closed bridge, balanced.  
Electrical connections  
1
+ Supply  
The integrated bridge balancing circuitry eliminates  
possible induced parasites due to connections to an  
external circuit.  
2
5
EK11 / 21  
(CS1 /2)  
+ Signal  
EP (CP) : Closed bridge, balanced .  
Interchangeability :  
Output signal to 1%  
4
3
- Signal  
- Supply  
1
+ Supply  
ED-EP 11 / 21  
(CA - CP 1 / 2)  
ER (CTi) : Closed bridge, balanced .  
Thermal drifts compensation :  
zero and output signal.  
+ Signal  
5
ER-ET 11 / 21  
(CTi - CT 1 / 2)  
4
3
- Supply  
ET (CT) : Closed bridge, balanced .  
Thermal drifts compensation :  
zero and output signal .  
- Signal  
1
3
+ Supply  
Output signal to 1%  
Interchangeability .  
ED71 (CA7)  
+ Signal  
4
2
- Signal  
- Supply  
Other models, EC-EL with high level output signal, 0-10 V, or 0-5 V, or 4-20 mA:  
consult us.  
Sectionned wiew  
Soldered contacts  
Screen printed gauges  
Ceramic diaphragm  
www.baumer.com/process  
Data sheet A12.20  
Page 1  
Design and specifications subject to change without notice  
Options  
Particular technical specifications  
Zitex humidity protector (gauge pressure models only). Code 0811  
Polyester flat cable, 5 wires, 50 mm soldered on sensors serie 1 or 2. Code 2251  
Kapton flat cable, 4 wires, 25 mm. Standard for ED71 (soldered). Code 2252  
Flexible single wires, soldered on sensor, length to be specified. Code 2253  
All other options : please consult us.  
Pressure sensors, high level output signal models EC - EL  
Above described pressure sensors address OEM users, taking in charge the electronic conditioning of the sensor (excitation, signal amplification)  
depending upon their actual needs.  
For those who would not have such capacities, or for whom, the annual requirement would not allow a satisfying playback on the cost of development  
of such electronic circuitry, BAꢀMER can supply sensors associated with p.c.boards usually fitted in transmitters, delivering a normalised high level  
output signal for the rated range : 4-20 mA, 1-5 V, 0-10V, directly usable by peripheric equipments as : displays, recorders, controllers, P.L.C.s, etc.  
Ordering Details - EK-ED-EP-ER-ET  
Exxxxxx  
Serie 1 - Ø 42 mm  
Model  
Pressure sensors  
1´ digit  
Range bar  
0.2  
code  
E
RB  
RC  
RD  
RE  
RG  
R
R
R
R
R
0.5  
0.75  
1.5  
2
A
A
A
Type  
Serie 1 - Ø 42 mm  
2´...4´ digit  
K11  
D11  
P11  
R11  
T11  
Serie 2 - Ø 34 mm  
Range bar  
code  
MB  
MC  
LC  
LE  
LI  
LL  
LR  
HR  
ER  
EZ  
EP  
0.6  
1
A
A
A
A
A
A
A
A
A
A
A
R
R
R
R
R
R
R
R
Serie 2 - Ø 34 mm  
2
K21  
D21  
P21  
R21  
T21  
5
10  
20  
50  
100  
200  
350  
400  
D71  
Serie 7 - Ø 18 mm  
Serie 7 - Ø 18 mm  
Pressure range  
See codes in tables  
5´...6´ digit  
7´ digit  
Range bar  
code  
xx  
FA  
FB  
DB  
FE  
DE  
DG  
CG  
DL  
CL  
CQ  
CR  
CU  
CZ  
2
4
A
A
A
A
A
A
A
A
A
A
A
A
A
R
R
R
R
R
R
R
R
R
R
R
R
R
Pressure type  
Absolute  
Gauge  
6
A
10  
R
16  
25  
40  
60  
100  
160  
250  
400  
600  
Be careful :  
Max. operating temperature range is limited  
to 70°C for absolute pressure versions.  
www.baumer.com/process  
Data sheet A12.20  
Page 2  
Design and specifications subject to change without notice  
Technical Data (20°C)  
SERIE 1 - Ø 42 mm - Low pressure ranges  
MODELS SPECIFICATIONS EK11 - ED11 - EP11 - ER11 - ET11  
RANGE IDENTIFICATION :  
RB (1)  
RC (1)  
RD  
RE  
RG  
RATED RANGE (R.R.) :  
(bar)  
0.2  
2.9  
0.22  
0.4  
0.5  
7.25  
0.55  
1  
0.75  
10.9  
0.83  
1.5  
1.5  
21.75  
1.65  
3  
2
29  
2.2  
4  
(≅ psi)  
(bar)  
(bar)  
Max. admissible pressure, without derating of specs :  
Burst pressure :  
OUTPUT SIGNAL AT RATED RANGE: (2)  
EK11  
(mV)  
( 30%)  
ED11  
EP11  
ER11  
ET11  
25  
22  
18  
20  
15  
50  
45  
35  
40  
30  
45  
42  
35  
38  
30  
65  
60  
45  
55  
40  
55  
50  
40  
45  
30  
( 30%)  
( 1%)  
( 30%)  
( 1%)  
GLOBAL ERROR (max.) :  
(non linearity + hysteresis + repeatability)  
( % R.R.)  
1
0.4  
0.4  
0.4  
0.4  
DIMENSIONS  
See fig. 1  
(1) Gauge pressure only.  
SPECIFICATIONS : ALL MODELS  
EK11  
ED11  
EP11  
ER11  
ET11  
EXCITATION VOLTAGE :  
Nominal :  
Maximum :  
(Volt)  
(Volt)  
10  
30  
10  
30  
10  
30  
10 (3)  
10 (3)  
10 (3)  
10 (3)  
BRIDGE IMPEDANCE  
Input :  
Ouput :  
(kOhm)  
30% (kOhm)  
15 30%  
15  
6  
15  
6  
10  
6  
15  
6  
10  
TEMPERATURE LIMITS :  
Operating :  
Compensated :  
(°C)  
(°C)  
-55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125  
n.a. n.a. n.a. -10 to +55 -10 to +55  
THERMAL DRIFTS : (2)  
Zero :  
Output signal :  
(µV / °C)  
(% / °C)  
30  
-0.04  
30  
-0.04  
30  
-0.04  
0.2 (non cumulative)  
6
0.01  
6
0.01  
LONGTERM ZERO DRIFT :  
(% R.R. / year)  
INITIAL ZERO UNBALANCE (2)  
(mV)  
5ꢀꢀ  
2
2
1
1
(2) Under nominal excitation voltage : 1ꢀ V  
(3) 5 V. optional.  
SERIE 2 - Ø 34 mm - Low, medium and high pressure ranges  
MODELS SPECIFICATIONS EK21 - ED21 - EP21 - ER21 - ET21  
RANGE IDENTIFICATION :  
RATED RANGE : (R.R.) :  
MB MC LC  
0.6  
9
0.66 1.1 2.2  
1.8 3 6  
LE  
5
LI  
LL  
20  
LR HR ER* EZ* EP*  
50 100 200 350 400  
(bar)  
(psi)  
(bar)  
1
15  
2
30  
10  
75 150 300 750 1500 3000 5250 6000  
5.5 11 22 55 110 220 385 440  
12 25 50 125 250 450 550 600  
Max. admissible pressure, without derating of specs :  
Burst pressure :  
(bar)  
OUTPUT SIGNAL AT RATED RANGE : (2)  
(mV)  
( 30%)  
( 30%)  
( 1%)  
( 30%)  
( 1%)  
EK21  
ED21  
EP21  
ER21  
ET21  
27  
25  
20  
24  
15  
35  
33  
26  
27  
20  
55  
50  
40  
37  
30  
65  
60  
50  
48  
40  
70  
65  
50  
52  
40  
70  
65  
50  
52  
40  
70  
65  
50  
52  
40  
70  
65  
50  
52  
40  
65  
60  
50  
48  
40  
45  
40  
35  
36  
20  
35  
30  
20  
24  
15  
GLOBAL ERROR (max.)  
(non linearity + hysteresis + repeatability)  
( % R.R.)  
0.8 0.4 0.4  
0.4 0.3  
0.3  
0.2 0.2  
0.2 0.4  
0.4  
DIMENSIONS  
See fig. 2  
Models with* : absolute pressure only.  
SPECIFICATIONS : ALL MODELS  
EK21  
ED21  
EP21  
ER21  
ET21  
EXCITATION VOLTAGE :  
Nominal :  
Maximum :  
(Volt)  
(Volt)  
10  
30  
10  
30  
10  
30  
10 (3)  
10 (3)  
10 (3)  
10 (3)  
BRIDGE IMPEDANCE :  
Input :  
Ouput :  
(kOhm)  
30% (kOhm)  
15 30%  
15  
6  
15  
6  
10  
6  
15  
6  
10  
TEMPERATURE LIMITS :  
Operating :  
Compensated :  
(°C)  
(°C)  
-55 to +125 -55 to +125 -55 to +125 -55 to +125 -55 to +125  
n.a. n.a. n.a. -10 to +55 -10 to +55  
THERMAL DRIFTS : (2)  
Zero :  
Ouput signal :  
(µV / °C)  
(% / °C)  
30  
-0.04  
30  
-0.04  
30  
-0.04  
0.2 (non cumulative)  
6
0.01  
6
0.01  
LONGTERM ZERO DRIFT :  
(% R.R. / year)  
(mV)  
INITIAL BRIDGE UNBALANCE : (2)  
500  
2
2
1
1
(2) ꢀnder nominal excitation voltage 10 V  
www.baumer.com/process  
(3) 5 V optional.  
Data sheet A12.20  
Page 3  
Design and specifications subject to change without notice  
Technical Data (20°C)  
SERIE 7 - Ø 18 mm - Low, medium and high pressure ranges  
SPECIFICATIONS  
RANGE IDENTIFICATION :  
RATED RANGE : (R.R.)  
ED71  
FA FB DB FE DE DG CG DL CL CQ CR Cꢀ CZ  
(bar)  
(psi)  
(bar)  
2
4
6
10 16 25 40 60 100 160 250 400 600  
30 60 90 150 250 350 600 900 500 2500 4000 6000  
12 20 32 50 80 120 200 320 500 800 800  
12 18 30 48 75 120 180 300 480 600 1000  
1
-
Max. admissible pressure, without derating of specs :  
Burst pressure : ≥  
OUTPUT SIGNAL AT R.R. : (1)  
5
7
8
(bar)  
-
30%  
(mV)  
20 20 20 20 22 22 25 22 25 27 25 30 25  
GLOBAL ERROR :  
(non linearity + hysteresis + repeatability)  
(% R.R.)  
0.4  
0.6  
EXCITATION  
Nominal :  
Maximum :  
(Volt)  
(Volt)  
10  
20  
BRIDGE IMPEDANCE  
Input :  
Output :  
(kOhm)  
(kOhm)  
Closed bridge : 6  
15 30%  
TEMPERATURE LIMITS  
Operating :  
Compensated :  
(°C)  
(°C)  
-55 to +125  
n.a.  
THERMAL DRIFTS  
Zero :  
Output signal :  
(µV / °C)  
(% / °C)  
30  
0.01  
LONGTERM ZERO DRIFT :  
INITIAL ZERO UNBALANCE (1)  
DIMENSIONS  
(% R.R. / year)  
(mV)  
0.2 (non cumulative)  
See fig. 3  
2
(1) ꢀnder nominal excitation voltage : 10 V  
Dimensions  
Tightening force loading  
area (ø 40)  
e
Figure 1  
Range identification  
Model  
identification  
e : mm  
1 ꢀ  
RB  
RC  
RD  
RE  
RG  
5.30  
5.35  
5.40  
5.45  
5.55  
Connecting pads  
2.54 mm pitch  
Option : ZITEX humidity protector  
(gauge pressure measurement only)  
Ventilation hole (gauge  
pressure measurement)  
Series 1  
e
Tightening force  
loading area (ø 30)  
Figure 2  
Range identification  
Model  
Identification  
e : mm  
1 ꢀ  
MB  
6.30  
6.35  
6.45  
6.625  
6.85  
7.30  
8.05  
8.55  
Connecting pads  
2.54 mm pitch  
MC LC  
LE  
LI  
LL  
LR HR ER  
EZ  
Option : ZITEX humidity  
protector (gauge pressure  
measurement only)  
Ventilation hole (gauge  
pressure measurement)  
EP  
Series 2  
Figure 3  
Model  
Identification  
e : mm  
1 ꢀ  
Tightening force  
loading area (ø 15)  
FA  
FB DB  
FE DE  
DG CG  
DL CL  
CQ  
6.25  
6.30  
6.45  
6.55  
6.85  
7.05  
7.30  
7.65  
7.82  
Connec
2.54 mm
Option : ZITEX humidity protector  
(gauge pressure measurement only)  
CR  
Ventilation hole (gauge  
pressure measurement)  
Series 7  
Cꢀ  
CZ  
www.baumer.com/process  
Design and specifications subject to change without notice  
Data sheet A12.20  
Page 4  

相关型号:

EK21LIA

Ceramic Sensor, Absolute, Round
IVO

EK21LLA

Ceramic Sensor, Absolute, Round
IVO

EK21LLR

Ceramic Sensor, Gage, Round
IVO

EK21LRA

Ceramic Sensor, Absolute, Round
IVO

EK21LRR

Ceramic Sensor, Gage, Round
IVO

EK21MBR

Ceramic Sensor, Gage, Round
IVO

EK21MCA

Ceramic Sensor, Absolute, Round
IVO

EK21MCR

Ceramic Sensor, Gage, Round
IVO

EK22

EVALUATION KIT FOR PA94/PA95
APEX

EK22210000J0G

Barrier Strip Terminal Block
AMPHENOL

EK22212000J0G

Barrier Strip Terminal Block
AMPHENOL

EK22214000J0G

Barrier Strip Terminal Block
AMPHENOL