LCA125STR [IXYS]

Transistor Output SSR, 1-Channel, 3750V Isolation, DIP-6;
LCA125STR
型号: LCA125STR
厂家: IXYS CORPORATION    IXYS CORPORATION
描述:

Transistor Output SSR, 1-Channel, 3750V Isolation, DIP-6

输出元件 光电
文件: 总7页 (文件大小:129K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LCA125  
Single-Pole, Normally Open  
OptoMOS® Relay  
INTEGRATED  
CIRCUITS  
DIVISION  
Parameter  
Blocking Voltage  
Load Current  
Ratings  
300  
Units  
Description  
VP  
mArms / mADC  
LCA125 is a 300V, 170mA, 16, normally open  
(1-Form-A) solid state relay that uses optically coupled  
MOSFET technology to provide 3750Vrms of input to  
output isolation.  
170  
On-Resistance (max)  
16  
Its optically coupled outputs, which use the patented  
OptoMOS architecture, are controlled by a highly  
efficient GaAIAs infrared LED.  
Features  
3750Vrms Input/Output Isolation  
Low Drive Power Requirements (TTL/CMOS  
Compatible)  
High Reliability  
Arc-Free With No Snubbing Circuits  
FCC Compatible  
VDE Compatible  
Use the LCA125 to replace mechanical relays,  
and gain the superior reliability associated with  
semiconductor devices. Because they have no moving  
parts, they offer faster, bounce-free switching in a more  
compact surface mount or through hole package.  
No EMI/RFI Generation  
Small 6-Pin Package  
Machine Insertable, Wave Solderable  
Surface Mount Tape & Reel Version Available  
Approvals  
UL Recognized Component: File # E76270  
CSA Certified Component: Certificate 1172007  
Certified to:  
EN60950-1: 2006  
EN60950-1: 2005  
Applications  
TUV Certificate: B 09 07 49410 004  
Telecommunications  
Telecom Switching  
Tip/Ring Circuits  
Modem Switching (Laptop, Notebook,  
Pocket Size)  
Ordering Information  
Part #  
LCA125  
Description  
6-Pin DIP (50/Tube)  
Hook Switch  
Dial Pulsing  
Ground Start  
LCA125S  
LCA125STR  
6-Pin Surface Mount (50/Tube)  
6-Pin Surface Mount (1,000/Reel)  
Ringing Injection  
Instrumentation  
Multiplexers  
Pin Configuration  
AC/DC Configuration  
Data Acquisition  
Electronic Switching  
I/O Subsystems  
Meters (Watt-Hour, Water, Gas)  
Medical Equipment—Patient/Equipment Isolation  
Security  
1
2
3
6
5
4
+ Control  
– Control  
Load  
Do Not Use  
Load  
Do Not Use  
DC Only Configuration  
1
2
3
6
5
4
+ Control  
– Control  
+ Load  
– Load  
Aerospace  
Industrial Controls  
Do Not Use  
Switching Characteristics of  
Normally Open (Form A) Devices  
Form-A  
IF  
90%  
10%  
ILOAD  
t
t
off  
on  
Pb  
e3  
DS-LCA125-R09  
1
www.ixysic.com  
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
Absolute Maximum Ratings @25ºC  
Absolute Maximum Ratings are stress ratings. Stresses in  
excess of these ratings can cause permanent damage to  
the device. Functional operation of the device at conditions  
beyond those indicated in the operational sections of this  
data sheet is not implied.  
Parameter  
Blocking Voltage  
Ratings  
300  
Units  
VP  
Reverse Input Voltage  
5
50  
V
Input Control Current  
Peak (10ms)  
mA  
A
1
Input Power Dissipation 1  
Total Power Dissipation 2  
Isolation Voltage, Input to Output  
Operational Temperature  
Storage Temperature  
150  
mW  
mW  
Vrms  
°C  
800  
3750  
-40 to +85  
-40 to +125  
°C  
1
2
Derate linearly 1.33 mW / ºC  
Derate linearly 6.67 mW / ºC  
Electrical Characteristics @25ºC (Unless Otherwise Noted)  
Parameter  
Conditions  
Symbol  
Min  
Typ  
Max  
Units  
Output Characteristics  
Load Current  
AC/DC Configuration, Continuous 1  
DC Configuration, Continuous 1  
Peak  
-
-
-
-
-
-
-
170  
300  
400  
mArms / mADC  
mADC  
IL  
-
t=10ms  
ILPK  
mAP  
On-Resistance 2  
AC/DC Configuration  
DC Configuration  
IL=170mA  
IL=300mA  
VL=300V  
-
-
-
10  
4
16  
5
RON  
Off-State Leakage Current  
Switching Speeds  
ILEAK  
-
1
µA  
Turn-On  
ton  
toff  
-
-
-
-
-
5
5
-
ms  
ms  
pF  
IF = 5mA, VL = 10V  
50V, f=1MHz  
Turn-Off  
Output Capacitance  
COUT  
50  
Input Characteristics  
Input Control Current to Activate  
Input Control Current to Deactivate  
Input Voltage Drop  
IL = 170mA  
-
IF  
IF  
-
-
5
-
mA  
mA  
V
0.4  
0.9  
-
0.7  
1.2  
-
IF = 5mA  
VR = 5V  
VF  
IR  
1.4  
10  
Reverse Input Current  
Common Characteristics  
Capacitance, Input to Output  
µA  
-
CI/O  
-
3
-
pF  
1 If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded.  
2 Measurement taken within 1 second of on-time.  
R09  
2
www.ixysic.com  
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*  
Typical LED Forward Voltage Drop  
(N=50, IF=5mA)  
Typical Turn-On Time  
(N=50, IF=5mA, IL=170mADC  
Typical Turn-Off Time  
(N=50, IF=5mA, IL=170mADC)  
)
35  
30  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
25  
20  
15  
10  
5
0
0
0
1.17  
1.19  
1.21  
1.23  
1.25  
0.875 1.225 1.575 1.925 2.275 2.625 2.975  
0.35 0.40 0.45 0.50 0.55 0.60 0.65  
LED Forward Voltage (V)  
Turn-On Time (ms)  
Turn-Off Time (ms)  
Typical IF for Switch Operation  
(N=50, IL=170mADC  
Typical IF for Switch Dropout  
Typical On-Resistance Distribution  
)
(N=50, IL=170mADC  
)
(N=50, IF=5mA, IL=170mADC)  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
0
0
0
0.30  
0.42  
0.54  
0.66  
0.78  
0.90  
0.18  
0.30  
0.42  
0.54  
0.66  
0.78  
8.25  
8.75  
9.25  
9.75  
10.25  
LED Current (mA)  
LED Current (mA)  
On-Resistance (:)  
Typical Blocking Voltage Distribution  
(N=50)  
25  
20  
15  
10  
5
0
302.5 311.5 320.5 338.5 338.5 347.5  
Blocking Voltage (VP)  
Typical Turn-Off Time  
Typical Turn-On Time  
vs.LED Forward Current  
vs. LED Forward Current  
Typical LED Forward Voltage Drop  
vs.Temperature  
(IL=170mADC  
)
(IL=170mADC  
)
0.80  
0.75  
0.70  
0.65  
0.60  
0.55  
0.50  
0.45  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
IF=50mA  
I =10mA  
IFF=5mA  
0
5
10 15 20 25 30 35 40 45 50  
-40 -20  
0
20  
40  
60  
80 100 120  
0
5
10 15 20 25 30 35 40 45 50  
LED Forward Current (mA)  
Temperature (ºC)  
LED Forward Current (mA)  
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R09  
www.ixysic.com  
3
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*  
Typical Turn-On Time  
vs.Temperature  
Typical On-Resistance  
Typical Turn-Off Time  
vs.Temperature  
vs.Temperature  
(IL=170mADC  
)
(IF=5mA, IL=170mADC  
)
(IF=5mA, IL=170mADC  
)
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0
60  
50  
40  
30  
20  
10  
0
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
IF=5mA  
IF=10mA  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (ºC)  
Temperature (ºC)  
Temperature (ºC)  
Typical IF for Switch Operation  
vs.Temperature  
Typical IF for Switch Dropout  
vs.Temperature  
Typical Load Current vs. Load Voltage  
(IF=5mA)  
(IL=170mADC  
)
(IL=170mADC)  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
200  
150  
100  
50  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
0
-50  
-100  
-150  
-200  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-2.0 -1.5 -1.0 -0.5  
0
0.5 1.0 1.5 2.0  
Temperature (ºC)  
Temperature (ºC)  
Load Voltage (V)  
Maximum Load Current  
vs.Temperature  
Typical Blocking Voltage  
vs.Temperature  
Typical Leakage vs.Temperature  
Measured across Pins 4&6  
(IL=170mADC  
)
300  
250  
200  
150  
100  
50  
0.025  
0.020  
0.015  
0.010  
0.005  
0
340  
335  
330  
325  
320  
315  
310  
305  
DC Configuration  
IF=10mA  
IF=5mA  
AC/DC Configuration  
IF=10mA  
IF=5mA  
-40 -20  
0
20  
40  
60  
80 100 120  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (ºC)  
Temperature (ºC)  
Temperature (ºC)  
Energy Rating Curve  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
10Ps 100Ps 1ms 10ms 100ms 1s  
10s 100s  
Time  
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R09  
4
www.ixysic.com  
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
Manufacturing Information  
Moisture Sensitivity  
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated  
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to  
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product  
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper  
operation of our devices when handled according to the limitations and information in that standard as well as to any  
limitations set forth in the information or standards referenced below.  
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced  
product performance, reduction of operable life, and/or reduction of overall reliability.  
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according  
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.  
Device  
Moisture Sensitivity Level (MSL) Rating  
LCA125 / LCA125S  
MSL 1  
ESD Sensitivity  
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.  
Reflow Profile  
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020  
must be observed.  
Device  
MaximumTemperature xTime  
LCA125 / LCA125S  
250ºC for 30 seconds  
Board Wash  
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to  
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as  
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary  
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.  
Cleaning methods that employ ultrasonic energy should not be used.  
Pb  
e3  
R09  
www.ixysic.com  
5
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
MECHANICAL DIMENSIONS  
LCA125  
8.382 0.381  
(0.330 0.015)  
PCB Hole Pattern  
7.239 TYP  
2.54 0.127  
(0.100 0.005)  
(0.285 TYP)  
6 - 0.800 DIA.  
(6 - 0.031 DIA.)  
2.540 0.127  
(0.100 0.005)  
9.144 0.508  
(0.360 0.020)  
6.350 0.127  
(0.250 0.005)  
7.620 0.127  
(0.300 0.005)  
7.620 0.254  
(0.300 0.010)  
Pin 1  
0.254 0.0127  
(0.010 0.0005)  
1.651 0.254  
(0.065 0.010)  
6.350 0.127  
(0.250 0.005)  
5.080 0.127  
(0.200 0.005)  
3.302 0.051  
(0.130 0.002)  
4.064 TYP  
(0.160 TYP)  
Dimensions  
mm  
(inches)  
0.457 0.076  
(0.018 0.003)  
LCA125S  
0.635 0.127  
(0.025 0.005)  
PCB Land Pattern  
8.382 0.381  
(0.330 0.015)  
2.54 0.127  
(0.100 0.005)  
2.54  
(0.10)  
9.524 0.508  
(0.375 0.020)  
6.350 0.127  
(0.250 0.005)  
8.90  
(0.3503)  
1.65  
(0.0649)  
7.620 0.254  
(0.300 0.010)  
0.254 0.0127  
(0.010 0.0005)  
0.457 0.076  
(0.018 0.003)  
Pin 1  
1.651 0.254  
(0.065 0.010)  
0.65  
3.302 0.051  
(0.130 0.002)  
(0.0255)  
4.445 0.254  
(0.175 0.010)  
Dimensions  
mm  
(inches)  
1.651 0.254  
(0.065 0.010)  
R09  
6
www.ixysic.com  
LCA125  
INTEGRATED  
CIRCUITS  
DIVISION  
LCA125STR Tape & Reel  
330.2 Dia  
(13.00 Dia)  
Top Cover  
Tape Thickness  
0.102 Max  
W=16.00  
(0.63)  
B0 = 10.10  
(0.398)  
(0.004 Max)  
A0 = 10.10  
(0.398)  
P = 12.00  
(0.472)  
K0 = 4.90  
(0.19)  
K1 = 3.80  
(0.15)  
Dimensions  
mm  
(inches)  
User Direction of Feed  
Embossed  
Carrier  
NOTES:  
1. All dimensions carry tolerances of EIA Standard 481-2  
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2  
Embossment  
For additional information please visit our website at: www.ixysic.com  
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make  
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated  
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to  
its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.  
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other  
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe  
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.  
Specification: DS-LCA125-R09  
©Copyright 2012, IXYS Integrated Circuits Division  
OptoMOS® is a registered trademark of IXYS Integrated Circuits Division  
All rights reserved. Printed in USA.  
12/22/2012  
7

相关型号:

LCA125T/R

Transistor Output SSR, 1-Channel, 2500V Isolation,
IXYS

LCA126

Single Pole OptoMOS Relays
CLARE

LCA126

Single-Pole, Normally Open OptoMOS Relay
IXYS

LCA126L

Transistor Output SSR, 1-Channel
IXYS

LCA126LSTR

Transistor Output SSR, 1-Channel
IXYS

LCA126S

Single Pole OptoMOS Relays
CLARE

LCA126STR

Transistor Output SSR, 1-Channel, 3750V Isolation, SURFACE MOUNT, 6PIN
IXYS

LCA127

SINGLE POLE OptoMOS Relay
CLARE

LCA127L

SINGLE POLE OptoMOS Relay
CLARE