SCG05D10052-27BB [JDSU]
Benchtop/Rackmount Programmable Switches; BENCHTOP / RACKMOUNT程控交换机型号: | SCG05D10052-27BB |
厂家: | JDSU |
描述: | Benchtop/Rackmount Programmable Switches |
文件: | 总9页 (文件大小:1142K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
Benchtop/Rackmount Programmable Switches
SB/SC/SCG Series
Key Features
SB and SC series
• SB series can accommodate up to 48 channels and offer up
to two input channels
• SC series can accommodate up to 180 channels and offer
up to four input channels
• Low IL, 0.4 dB typical
• Excellent repeatability, +/- 0.003 dB typical
• High return loss (RL) > 65 dB typical
• GPIB and RS-232 remote control
SCG series
• Offer up to 45 input channels and 90 output channels
• Mass input reconfiguration possible
• Low IL, 0.5 dB typical for D configuration
• High RL > 65 dB typical
• Excellent repeatability, +/- 0.005 dB typical
• Replaces multiple switch elements with one switch instrument
Applications
The JDSU SB, SC, and SCG series of Benchtop/Rackmount Programmable Switches
can be controlled using the front panel keys and a numeric pad or via GPIB and
serial RS-232 interface. The SCG series ganged input switches allow a single
switch instrument to replace multiple switch elements while maintaining low loss.
In this series of switches, the inputs are ganged together in a particular sequence
and are thus able to offer three different modes of operation.
• Fiberoptic component testing and
measurement
• System testing
• Research and development (R&D)
• Mass reconfiguration of large numbers
of inputs/outputs with SCG series
(D configuration)
The SB, SC, and SCG series switches are available in four basic configurations:
• C configuration - is a single common input model (SB, SC)
• Connection of multiple wavelength
sources to any one of a number of
devices with SCG series (F configuration)
• Network monitoring
• D configuration - provides simultaneous connection of a bank of input fibers
to output fibers (SB, SC, SCG)
• E configuration - allows any input to be connected to any output while other
inputs/outputs are aligned to subsequent/adjacent channels. The switch is
non-blocking in this mode and other inputs/outputs are aligned (SB, SC, SCG)
• F configuration - enables one of the inputs to be aligned with an output in a
blocking sense, with a result in reduction of available output channels and a
low-loss M x N blocking switch. (SB, SC, SCG)
Safety Information
• Complies to CE requirements plus
UL3101-1 and CAN/CSA-C22.2 No.
1010.1
Operation of these switches is based upon JDSU's proven expanded beam lens
technology, which utilizes a precision stepper-motor to align optical channels.
The use of collimating lenses minimizes insertion loss (IL) and improves
repeatability and performance. Internal temperature control of the switching
mechanism ensures excellent operational stability.
WEBSITE: www.jdsu.com/test
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
2
Continued
Both single-mode (SM) and multimode (MM) versions of the SB, SC, and SCG
series switches are available. The series features the high level of performance
required for multi-unit testing in R&D and in manufacturing environments. The
compact, portable SB switch and the standard rackmount enclosure SC and SCG
switches are highly suited for applications in telecommunications, manufacturing,
and test environments.
JDSU's SB, SC and SCG switches are known in the fiberoptic industry for their
low IL and excellent repeatability. In addition to the many standard options
available, we also customize switches in this series to meet your specific applica-
tion needs.
Configurations
1x N Switching: C Configuration (SB and SC)
The 1xN configuration allows a single common input to be switched to
any of the outputs.
Ganged Switching: D Configuration (SB/SC/SCG)
The MxN configuration allows for mass reconfiguration of optical paths.
It provides simultaneous connections of a bank of inputs to outputs, and
replaces several 1xN with single switch element.
Sequential Switching: E Configuration (SB/SC/SCG)
The MxN configuration aligns any input with any output, while other
inputs are aligned to adjacent outputs.
Blocking Switching: F Configuration (SB/SC/SCG)
The MxN configuration allows any one of a bank of inputs to connect
with any output with only one active connection at a time.
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
3
SB Model Specifications
Parameter1
Single Common
C Configuration
Multiple Common
D Configuration
Multiple Common
E and F Configurations
Typical
Maximum
Typical
Maximum
Typical
Maximum
Insertion loss (IL)
Single-mode (SM)
Multimode (MM)
Return loss (RL)2
0.4 dB
0.4 dB
0.7 dB
0.7 dB
0.4 dB
0.4 dB
0.7 dB
0.7 dB
0.5 dB
0.5 dB
1.0 dB
1.0 dB
SM standard/analog
MM3 standard/analog
Polarization dependent loss (PDL) SM
IL stability4
> 65 dB
25/35 dB
0.02 dB
0.03 dB
60/65 dB
20/30 dB
0.05 dB
0.05 dB
> 65 dB
25/35 dB
0.02 dB
0.03 dB
60/65 dB
20/30 dB
0.05 dB
0.05 dB
65 dB
60 dB
20 dB
0.07 dB
0.05 dB
> 25 dB
0.03 dB
0.03 dB
Repeatability5
Sequential switching
Random switching
Crosstalk (maximum) SM
Maximum input power (optical)
Lifetime
0.003 dB
0.01 dB
0.005 dB
0.025 dB
0.005 dB
0.02 dB
-80 dB
300 mW
> 80 million cycles
0.01 dB
0.04 dB
0.005 dB
0.02 dB
0.01 dB
0.04 dB
Switching time
One channel
Each additional channel
Power supply
Power consumption
Control
300 ms
12 ms
100 to 240 V, 50 to 60 Hz
100 V A maximum
Local and remote via GPIB and serial RS-232 interfaces
Drivers for external switch modules
Operation temperature
Storage temperature
Humidity
Dimensions (W x H x D)
with rackmount kit (optional)6
Weight
Four open collector drivers with maximum 100 mA sink current
0 to 55 °C
- 40 to 70 °C
maximum 95 % RH from 0 to 55 °C non-condensing
21.2 x 8.9 x 35.5 cm
48.3 x 8.9 x 35.5 cm
3.75 kg
1. Excluding connectors. All optical measurements taken after temperature has been stabilized for one hour, at ambient (room) conditions.
2. RL specification based on 1 m pigtail length.
3. Values shown for 62.5 µm diameter maximum fiber core.
4. Drift of any channel relative to reference channel at 3 °C deviation of ambient temperature over a seven-day period.
5. Measured between two consecutive readings over 100 cycles.
6. ED000899-A-00 standard rackmount kit, ED000899-A-01 Japan rackmount kit. Requires two kits to mount two units side-by-side.
Please specify part number when ordering (if needed).
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
4
SC and SCG Models Specifications
Parameter1
Single Common
C Configuration
(SC model only)
Multiple Common
D Configuration
Multiple Common
E and F Configurations
Typical
Maximum
Typical
Maximum
Typical
Maximum
IL
SM
0.4 dB
-
0.4 dB
-
0.7 dB
-
0.7 dB
-
0.4 dB
0.5 dB
0.4 dB
0.5 dB
0.7 dB
1.0 dB
0.7 dB
1.0 dB
0.5 dB
0.7 dB
0.5 dB
0.7 dB
1.0 dB
1.5 dB
1.0 dB
1.5 dB
SC with 3 and 4 inputs and SCG models
MM
SC with 3 and 4 inputs and SCG models
RL2
SM standard/analog
MM4 standard/analog
PDL SM
> 65 dB
25/35 dB
0.02 dB
0.03 dB
60/65 dB
20/30 dB
0.05 dB
0.05 dB
> 65 dB
25/35 dB3
0.02 dB
0.03 dB
60/65 dB3
20/30 dB3
0.05 dB
> 65 dB
> 25 dB
0.03 dB
0.03 dB
60 dB
20 dB
0.07 dB
0.05 dB
IL stability5
0.05 dB
Repeatability7
Sequential switching
Random switching
Crosstalk (maximum) SM
Maximum input power (optical)
Lifetime
0.003 dB
0.01 dB
0.005 dB
0.025 dB
0.005 dB
0.02 dB
0.01 dB
0.04 dB
0.005 dB
0.02 dB
0.01 dB
0.04 dB
-80 dB
300 mW
> 80 million cycles (> 10 million cycles on SCG)
Switching time
One channel (SCG model)
Each additional channel (SCG model)
Power supply
300 ms (420 ms)
12 ms (20 ms)
100 to 240 V, 50 to 60 Hz
Power consumption
Control
100 V A maximum
Local and remote via GPIB and serial RS-232 interfaces
Drivers for external switch modules
Operation temperature
Storage temperature
Humidity
Dimensions (W x H x D) single (double height6)
Weight single (double height6)
Four open collector drivers with maximum 100 mA sink current
0 to 55 °C
-40 to 70 °C
Maximum 95 % RH from 0 to 55 °C non-condensing
48 x 13 x 37 cm (48 x 26.6 x 37 cm) excluding handles
9 kg (14 kg)
1. Excluding connectors. All optical measurements taken after temperature has been stabilized for one hour, at ambient (room) conditions.
2. RL specification based on 1 m pigtail length.
3. Analog version available on one and two input SC model switches (C and D configurations).
4. Values shown for 62.5 µm diameter maximum fiber core.
5. Drift of any channel relative to reference channel at 3 °C deviation of ambient temperature over a seven-day period.
6. Applies to SC model only.
7. Measured between two consecutive readings over 100 cycles.
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
5
SB Switch Configuration
Configuration
C
D
E
F
1xN
2xN
2xN
2xN
Output Channel
Counts (N)
2 to 48
4 to 44
2 to 44
2 to 20
SC Switch Configuration
Configuration
C
D
D
D
E
E
E
F
F
F
1xN
2xN
3xN
4xN
2xN
3xN
4xN
2xN
3xN
4xN
Output Channel
Counts (N)
2 to 180 4 to 180 6 to 180 8 to 180 2 to 180 3 to 180 4 to 180 2 to 90
3 to 60
4 to 45
SCG Switch Configurations
Configuration Restrictions
D: Up to 45 x 90 such that 'number of outputs' [N] is divisible by 'number of inputs' [M]
E: Up to 45 inputs [M] and up to 84 outputs [N], such that M + N is not more than 90
F: Up to 13 inputs [M] and up to 14 outputs [N], such that M x (N + 1) is not more than 93
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
6
SB Model Dimensions Diagram
(Specifications in inches [mm] unless otherwise noted.)
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
7
Ordering Information
SB Model Sample: SB2E10141+27XF000FP
SB
+ 2
Code
1C
Number of Input Channels
1 input channel, C config.
2 input channels, D config.
2 input channels, E config.
2 input channels, F config.
Code
Output Port Type1
Bulkheads on front
Pigtails on back
Code
Return Loss
Standard
Code
FP
Connector Type
1
4
X
A
B
FC/PC (bulkhead max. 24)
FC/APC (bulkhead max. 24)
SC/PC (bulkhead max. 24)
SC/APC (bulkhead max. 24)
No connector
2D
Analog
FA
2E
Bidirectional,
standard RL2
Bidirectional
analog RL2
SC
2F
SU
Code
Number of Output Channels
C
NC
002
2 output channels
Code
Input Port Type1
Bulkheads on front
Pigtails on back
:
:
1
4
Code
001
Cable Length (3mm diameter)
020
:
20 output channels
1 m
:
Code
Fiber Type (µm)
9/125
003
3 m
024
:
24 output channels
7
1
2
009
9 m
:
50/125
000
Not applicable (bulkheads only)
048
48 output channels
62.5/125
Code
Wavelength Range (nm)
1270 to 1670
F
1. Bulkheads and pigtails cannot be mixed in the same panel unless custom ordered.
2. For reverse direction, use bidirectional.
Q
B
850 to 1350 (MM only)
750 to 940 (MM only)
SB Switch Package Information
Connector Type
Bulkhead
Bulkhead
Pigtail
Chassis Size
2U bench top
2U bench top
2U bench top
2U bench top
Switch Configuration
Max Channel Counts (input + output)
C, D, E
24
22
49
22
F
C, D
F
Pigtail
If the configurations available do not meet your performance
requirements, please contact our global sales and customer
service team to discuss the potential for specialized solutions.
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
8
Ordering Information
Continued
SC Model Sample: SC2D30043+22XB009FP
SC
+ 2
Code
Input Port Type1
Bulkheads on front
Bulkheads on back
Pigtails on front
Pigtails on back
Code
Output Port Type1
Bulkheads on front
Bulkheads on back
Pigtails on front
Code
Return Loss
Standard
Code
001
Cable Length (3mm diameter)
1
2
3
4
1
2
3
4
X
A
B
1 m
Analog
003
3 m
Bidirectional,
standard RL2
Bidirectional
analog RL2
009
9 m
Pigtails on back
000
Not applicable (bulkheads only)
C
Code
002
:
Number of Output Channels2
Code
FP
Connector Type
Code
1C
2D
2E
Number of Input Channels
1 input channel, C config.
2 input channels, D config.
2 input channels, E config.
2 input channels, F config.
3 input channels, D config.
3 input channels, E config.
3 input channels, F config.
4 input channels, D config.
4 input channels, E config.
4 input channels, F config.
FC/PC (bulkheads max. 60/120)
FC/APC (bulkheads max. 60/120)
SC/PC (bulkheads max. 60/120)
SC/APC (bulkheads max. 60/120)
No connector
2 output channels
FA
:
Code
Fiber Type (µm)
9/125
SC
084
:
84 output channels
7
1
2
SU
2F
:
50/125
NC
3D
3E
180
180 output channels
62.5/125
3F
Code
Wavelength Range (nm)
1270 to1670
4D
4E
F
Q
B
850 to 1350 (MM only)
750 to 940 (MM only)
4F
1. Bulkheads and pigtails cannot be mixed in the same panel unless custom ordered.
2. Single height: 84 output channel maximum. Double height: 180 output channel maximum.
3. For reverse direction, use bidirectional.
SC Switch Package Information
Connector Type
Chassis Size
Switch Configuration
Max Channel Counts (input + output)
Bulkhead
3U 19” rack mount
3U 19” rack mount
3U 19” rack mount
3U 19” rack mount
3U 19” rack mount
6U 19” rack mount
6U 19” rack mount
6U 19” rack mount
6U 19” rack mount
6U 19” rack mount
C, D, E
C, D, E
F 2xN
F 3xN
F 4xN
C, D, E
C, D, E
F 2xN
F 3xN
F 4xN
60
85
Pigtail
Bulkhead / Pigtail
Bulkhead / Pigtail
Bulkhead / Pigtail
Bulkheads
46
29
24
120
181
92
Pigtails
Bulkhead / Pigtail
Bulkhead / Pigtail
Bulkhead / Pigtail
63
49
If the configurations available do not meet your performance
requirements, please contact our global sales and customer
service team to discuss the potential for specialized solutions.
BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
Ordering Information
Continued
SCG Model Sample: SCG06D20241+27XF000FP
SCG
+
2
Code
Number of Output
Channels2
Code
Number of Output
Channels2
Code
Fiber Type (µm)
9/125
Code
Cable Length
(3mm diameter)
7
1
2
05
:
5 input channels
005
5 output channels
001
003
009
000
1 m
50/125
:
:
:
3 m
62.5/125
08
:
8 input channels
048
:
48 output channels
9 m
:
:
Not applicable
(bulkheads only)
16
:
16 input channels
072
:
72 output channels
Code
Return Loss
Standard
:
:
X
B
45
45 input channels
090
90 output channels
Bidirectional,
standard RL3
Code
FP
Connector Type
FC/PC (maximum 60)
FC/APC (maximum 60)
SC/PC (maximum 60)
SC/APC (maximum 60)
No connector
Code
Output Port Type1
Bulkheads on front2
Bulkheads on back2
Pigtails on back
FA
Code
Configuration
D configuration
E configuration
F configuration
SC
D
E
1
2
4
Code
Wavelength Range (nm)
1270 to 1670
SU
F
NC
F
Q
B
850 to 1350 (MM only)
750 to 940 (MM only)
Code
Input Port Type1
Bulkheads on front2
Bulkheads on back2
Pigtails on back
1
2
4
1. The inputs and outputs must exit on opposite sides. (For example, if inputs exit from the
front, then the outputs must exit from the rear.)
2. For exact layout of bulkheads and labeling, contact JDSU.
3. For reverse direction, use bidirectional.
SCG Switch Package Information
Connector Type
Chassis Size
Switch Configuration
C, D, E, F
Max Channel Counts (input + output)
60 front panel; 60 rear panel
Bulkhead
3U 19” rack mount
3U 19” rack mount
Pigtail
C, D, E, F
90 front panel; 90 rear panel
If the configurations available do not meet your
performance requirements, please contact our global
sales and customer service team to discuss the
potential for specialized solutions.
UL is a registered trademark of Underwriters Laboratories Inc.
LabVIEW is a registered trademark of National Instruments Corporation.
All statements, technical information and recommendations related to the products herein are based upon information believed to be
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including
withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products herein are free from any
intellectual property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are trademarks of JDS
Uniphase Corporation. Other trademarks are the property of their respective holders. ©2006 JDS Uniphase Corporation. All rights
reserved. 10109644 Rev. 009 09/07 BTRKMTPROGSW.DS.TM.AE
Test & Measurement Regional Sales
www.jdsu.com/test
NORTH AMERICA
LATIN AMERICA
ASIA PACIFIC
EMEA
TEL: 1 866 228 3762
FAX: +1 301 353 9216
TEL: +55 11 5503 3800
FAX: +55 11 5505 1598
TEL: +852 2892 0990
FAX: +852 2892 0770
TEL: +49 7121 86 2222
FAX: +49 7121 86 1222
相关型号:
©2020 ICPDF网 联系我们和版权申明