COMMUNICATIONS MODULES & SUBSYSTEMS  
Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol,  
DWDM, 3R Transponder  
WaveReady™ Transponder 740 XLR  
Key Features  
• Client-side SFP modules support either single-mode  
fiber (SMF) or multimode fiber (MMF)  
• Automatic bit-rate detection and reporting  
• Multiple protocols supported at discrete bit rates of  
125 Mb/s to 3.125 Gb/s  
• Network optics support 16 ITU wavelengths on a 100 GHz  
grid over distances up to 180 km, without dispersion  
compensation or amplification  
• Facility loopback functionality on both network and  
client sides  
• Remote management via SNMP traps or TL1  
• 3R functionality at all supported bit rates and protocols  
Applications  
The WaveReady Transponder 740 (WRT-740) is a multi-rate, multi-protocol,  
auto-lock module that translates optical signals between a variety of client-side  
interfaces into a long-reach, single-mode, dense wavelength division multiplexing  
(DWDM) interface. This module includes small form factor pluggable (SFP)  
modules on the client side, loopback, and 3R (reshape, retime and re-  
amplify/regenerate) functionality.  
Wavelength services  
• Metro optical access overlay  
• Storage area network (SAN) and  
GigE extension services  
SFP modules optimized for a wide range of protocols are available for single-  
mode and multimode fiber. Supported protocols include 100Base-FX Ethernet,  
Gigabit Ethernet (GigE), ESCON, Fibre channel, FICON, and OC-3 to OC-48.  
Supported data rates range from 125 Mb/s to 3.125 Gb/s. The WRT-740's bit-rate  
and protocol independence gives service providers the flexibility to meet the  
shifting service demands of customers without changing installed equipment.  
Compliance  
• FCC Part 15 (Class A); UL 60950  
3rd Edition, December 2000;  
CAN/CSA-C22.2 No. 950-95;  
NEBS Level 3; GR-63-CORE;  
GR-1089-CORE; GR-78-CORE; CE;  
IEC 60950; ETS300-386; EN 55022  
(Class B); 73/23/EEC  
Remote management lowers operating, administration and management  
expenditures (OPEX). A WaveReady communications module manages the WRT-  
740 with TL1 and a command line or telnet interface, or with TL1 or simple  
network management protocol (SNMP) and the JDSU Node Manager software.  
An embedded supervisory channel on the network side is also available for remote  
management of standalone modules without the cost of extra fiber or an extra  
WaveReady communications module.  
Full 3R functionality allows multiple WRT-740 modules to be deployed in series  
for very long reach applications. Loopback facilitates fault isolation and  
troubleshooting.  
NORTH AMERICA: 800 498-JDSU (5378)  
WORLDWIDE: +800 5378-JDSU  
WEBSITE: www.jdsu.com  
WRT-740  
2
Point-to-Point Four-Channel DWDM Link  
WaveReady 3500-F Shelf  
WaveReady 3500-F Shelf  
MON  
MON  
RX  
TX  
RX  
TX  
RX  
RX  
WTX  
WTX  
TX WRXTX  
TX WRXTX  
RX  
RX  
TX WTX  
TWTX  
TWRT-740  
TXWRT-740  
TX  
RX  
TX  
RX  
MON  
MON  
Typical Link Budget  
Data Rate  
Minimum Rx Power  
Total Power Budget  
Maximum Distance  
OC-48  
Gigabit Ethernet  
-28.5 dBm  
-30 dBm  
27.9 dB  
29.4 dB  
111 km  
117 km  
Point-to-point Single Channel DWDM Link  
Typical Link Budget  
Data Rate  
Minimum Rx Power  
Total Power Budget  
Maximum Distance  
OC-48  
Gigabit Ethernet  
-28.5 dBm  
-30 dBm  
33.5 dB  
35 dB  
134 km  
140 km  
WRT-740  
3
Network Optical Specifications  
Parameter  
Specifications  
Optical Path between Transmitter and Receiver Connectors  
Dispersion at OC-48  
Optical return loss of cable plant, including any connectors  
Discrete reflectance between transmit and receive connectors  
Maximum link budget at OC-48 including dispersion  
Maximum  
3240 ps/nm  
24 dB  
27 dB  
31.5 dB  
36 dB  
Minimum  
Maximum  
Minimum  
Typical  
Transmitter  
Wavelength range on ITU grid  
Frequency range (32 frequencies, 100 GHz spacing)  
Wavelength accuracy  
1530 to 1561 nm  
192.1 to 195.9 THz  
100 pm  
5 dBm  
7 dBm  
Maximum  
Minimum  
Typical  
Mean output power  
Maximum  
Minimum  
Typical  
10 dBm  
8.2 dB  
9.5 dB 1  
Extinction ratio  
Receiver  
Sensitivity at 100BaseF to GE, BER=1x10-10  
Sensitivity at OC-48, BER=1x10-10  
Overload  
OSNR tolerance at BER=1x10-12  
Optical path penalty on standard single-mode fiber  
Reflectance of receiver at receiver connector  
LOS activation threshold  
Minimum  
Minimum  
Minimum  
Minimum  
Maximum  
Maximum  
Typical  
-30 dBm  
-28.5 dBm  
-8 dBm 2  
20 dB 3  
2 dB 4  
-27 dB  
-32 dBm  
-30 dBm  
LOS deactivation threshold  
Typical  
Note: All specifications are guaranteed over the life, operating temperatures, wavelength range, and input voltage range specified. This product should be deployed in  
accordance with each company's deployment directives.  
1. At OC-48  
2. Management communications at OC-3 require input power less than -15 dBm  
3. With receive power of -27 dBm with no other signal impairments at EOL over all temperature ranges  
4. Dispersion penalty only  
WRT-740  
4
Other Specifications  
Parameter  
Condition  
Specifications  
Electrical  
Power consumption  
Over temperature range EOL  
Typical  
16.5 W  
20 W  
38 V  
Maximum  
Minimum  
Typical  
Supply voltage1  
48 V  
Maximum  
60 V  
Environmental  
Storage temperature  
Ambient operating temperature  
-40 to 85 °C  
-5 to 55 °C  
-5 to 55 °C short term, 96 hours continuous.  
No more than 15 days per year.  
Non-condensing  
Humidity  
5 to 95%  
Mechanical  
Weight (approximate)  
Dimensions (WxHxD)  
1.4 kg (3.1 pounds)  
25.4 x 223.5 x 175 mm  
(1.0 x 6.89 x 8.8 inches)  
WaveReady 3500-F or fan-equipped  
WaveReady 3100 shelf in standard  
19- or 24-inch rack  
Mounting options  
1. The DC power supply must be -48 V SELV output and certified by a nationally recognized test laboratory (NRTL)  
Interface Specifications  
Parameter  
Specification  
Provisioning, operations, administration, maintenance  
Via the WaveReady Communication Module 200. Remote management:  
SNMP and TL1 command mode through JDS Uniphase Node Manager  
software or TL1 through telnet or command-line application or SNMP.  
Communication with remote modules through an embedded supervisory channel.  
CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm),  
LOS B, LOS D, LOS F (loss of lock) LOOPBK (loopback), MGT (management).  
Client side ports A and B single mode or multimode fiber (SMF or MMF),  
SFP1, SFP2, SFP3, SFP4 or SFP5.  
Front panel LEDs  
Front panel ports  
Network side ports: C and D, SMF.  
Alarms  
CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm),  
LOS B, LOS D (loss of lock). Alarm relay open under normal operation.  
Relay closed when power is off and alarm is active.  
WRT-740  
5
Compatibility of Client SFPs  
Protocol  
Bit Rate  
SFP  
SMF Fiber  
100Base-FX Ethernet  
OC-3 IR-1/STM-1 S-1.1  
ESCON  
125 Mb/s  
155.52 Mb/s  
200 Mb/s  
SFP1 and SFP2  
SFP1 and SFP2  
SFP1 and SFP2  
SFP1 and SFP2  
SFP1 and SFP2  
SFP1  
SFP1  
SFP1  
SFP1  
SFP1  
D1 video  
270 Mb/s  
OC-12/STM-4 S-4.1  
FICON LX single mode  
Fibre channel 100-SMLL-L  
Gigabit Ethernet 1000Base-LX  
Fibre channel 200-SMLL-I  
OC-48/STM-16 I-16  
OC-48 FEC  
622.08 Mb/s  
1.0625 Gb/s  
1.0625 Gb/s  
1.250 Gb/s  
2.125 Gb/s  
2.48832 Gb/s  
2.7 Gb/s  
SFP1  
MMF Fiber  
100Base-FX Ethernet  
ESCON  
FICON LX  
FICON SX  
Fibre channel 100-M5-SN-I  
Gigabit Ethernet 1000Base-SX  
125 Mb/s  
200 Mb/s  
1.0625 Gb/s  
1.0625 Gb/s  
1.0625 Gb/s  
1.250 Gb/s  
SFP2  
SFP2 or SFP11  
SFP3 or SFP11  
SFP4  
SFP4  
SFP4  
1. Due to the dual media (single-mode and multimode) support of this transmitter, fulfillment of this protocol requires a single-mode fiber offset launch mode conditioning  
patch cord. The offset launch mode conditioning cable lowers the launch power by 0.5 dB and incurs a similar penalty on the sensitivity.  
WRT-740  
6
Ordering Information  
For more information on this or other products and their availability, please contact your local JDSU account manager or  
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at  
customer.service@jdsu.com.  
Sample: WRT-740DT240B-153  
WRT-740DT240B-  
Code  
135  
137  
144  
145  
146  
147  
148  
149  
152  
153  
154  
155  
156  
157  
158  
159  
ITU Channel/Frequency1  
193.5 THz/1549.32 nm  
193.7 THz/1547.72 nm  
194.4 THz/1542.14 nm  
194.5 THz/1541.35 nm  
194.6 THz/1540.56 nm  
194.7 THz/1539.77 nm  
194.8 THz/1538.98 nm  
194.9 THz/1538.19 nm  
195.2 THz/1535.82 nm  
195.3 THz/1535.04 nm  
195.4 THz/1534.25 nm  
195.5 THz/1533.47 nm  
195.6 THz/1532.68 nm  
195.7 THz/1531.90 nm  
195.8 THz/1531.12 nm  
195.9 THz/1530.33 nm  
1. Other channels are available upon request.  
SFP Sample: WRT-SFPS12SB1310  
WRT-SFP  
Code  
Model  
S24SB1310  
S12SB1310  
M20SB0850  
S20SB1310  
SFP1  
SFP2  
SFP3  
SFP4  
All statements, technical information and recommendations related to the products herein are based upon information believed to be  
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any  
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves  
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, includ-  
ing withdrawal at any time of  
a product offered for sale herein. JDSU makes no representations that the products  
herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU, Waveready, and the  
JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. ©2005 JDS  
Uniphase Corporation. All rights reserved. 10143107 Rev. 004 0808 WRT740.DS.CMS.AE  
NORTH AMERICA: 800 498-JDSU (5378)  
WORLDWIDE: +800 5378-JDSU  
WEBSITE: www.jdsu.com  

相关型号:

WRT-740DT240B-148

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-149

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-152

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-153

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-154

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-155

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-156

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-157

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-158

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-159

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-760DT240B-035

Path Protected, Client-Side SFP, Multi-Rate,Multi-Protocol, 3R DWDM Transponder
JDSU

WRT-760DT240B-037

Path Protected, Client-Side SFP, Multi-Rate,Multi-Protocol, 3R DWDM Transponder
JDSU