C44HKGP6100ZASJ

更新时间:2024-09-18 21:58:56
品牌:KEMET
描述:C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter

C44HKGP6100ZASJ 概述

C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter

C44HKGP6100ZASJ 数据手册

通过下载C44HKGP6100ZASJ数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC,  
for PFC and AC Filter  
Overview  
Applications  
The C44H Series are a polypropylene metallized film with  
cylindrical aluminium can type filled with liquid resin, screw  
terminals, plastic deck and overpressure safety device.  
Typical applications include commutation, power factor  
correction and AC harmonic filtering.  
Benefits  
• Overpressure safety device  
• High peak current capability  
• Long lifetime  
• Self-healing  
Part Number System  
C44H  
Series  
L
G
P
6100  
A
A
S
J
Case & Fixing  
Bolt Code  
Rated Voltage  
Terminal Style Capacitance Code (pF) Internal Code  
Internal Code  
Tolerance  
C44H = MKP  
Capacitors for K = 440 Vrms  
L = 330 Vrms  
G = Cylindrical P = M6  
Digits 9-11 indicate the A = Standard  
Z = Special  
J = 5%  
K = 10%  
aluminum  
Threaded Posts first three digits of the  
AC filtering  
case with M12 R = M10  
capacitance value.  
Digit 8 indicates the  
number of zeros to be  
added.  
bolt  
Threaded Posts  
It is not possible to manufacture every part number which could be created from coding description. Please refer to table of standard part numbers and  
ask KEMET for other possibilities.  
One world. One KEMET  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
1
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
Dimensions – Millimeters  
Diameter  
P
M
W
W1  
M1  
H1  
Ø = 65  
22.5  
6
13  
5
12  
12.5  
Ø ≥ 75  
35  
10  
25  
10  
12  
16  
All dimensions are in mm  
Maximum Driving Torque  
Terminals M6  
5 [N*m]  
Terminals M10  
Bolt M12  
8 [N*m]  
12 [N*m]  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
2
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
General Technical Data  
Reference Standards  
Dielectric  
IEC 61071  
Polypropylene film  
Non-inductive type winding  
25/70/56 – IEC 60068-1  
Climatic Category  
Maximum hot spot temperature  
Endurance Test IEC 61071  
Installation  
+75°C  
+65°C @ Case Temperature  
Whatever position  
Self extinguishing UL94 V0 plastic deck  
Electrical Characteristics  
Rated Voltage  
Surge Voltage  
Urms = (see table) VAC  
Us = (see table) VDC  
±5% or ±10%  
Capacitance Tolerance  
Dissipation Factor PP typical  
≤ 0.0002 at 25°C  
(tgδ0)  
Annual average ≤ 80% at 24°C  
On 30 days/year permanently 100%. on other days occasionally  
90%.  
Relative Humidity  
Dewing not admitted  
Capacitance deviation in  
temperature range (-40 +50°C)  
±1.5% maximum on capacitance value at 20°C  
Life Expectancy  
Life Expectancy  
Capacitance drop at end of life  
Failure Rate IEC 61709  
100,000 hours @ VRMS with THS ≤ 70°C  
- 5% (typical)  
See FIT Graph  
Test Methods  
Test voltage term to term (Utt)  
Test voltage term to case (Utc)  
Damp Heat  
1.5 x VRMS for 10 seconds at 25°C  
3,600 V ~ 50 Hz for 10 seconds  
IEC 60068-2-78  
Change of Temperature  
Vibration Strength  
IEC 60068-2-14  
IEC 60068-2-6  
NOTICE: Care should be taken to ensure that there still is electrical clearance of 15 mm between terminations and other live or earthed parts above the  
capacitor, in case of safety device activation.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
3
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
Table 1 – Ratings & Part Number Reference  
Cap  
Value  
(µF)  
Rth  
hs/amb  
°C/W  
Vrms  
Un  
Us  
Irms  
ESL <  
nH  
Rs  
Case  
dV/dt  
(V/µs)  
Part Number  
VAC  
VDC  
VDC  
A
mW  
Ø
H
100  
200  
300  
400  
500  
600  
100  
133  
133  
150  
200  
250  
330  
330  
330  
330  
330  
330  
440  
440  
440  
440  
440  
440  
700  
700  
700  
700  
700  
1050  
1050  
1050  
1050  
1050  
1050  
1500  
1500  
1500  
1500  
1500  
1500  
12.5  
12.5  
12.5  
12.5  
12.5  
12.5  
20  
20  
20  
20  
20  
25  
40  
45  
50  
55  
65  
30  
35  
40  
45  
50  
55  
100  
120  
160  
160  
170  
180  
145  
155  
170  
160  
175  
190  
3.4  
1.7  
1.6  
2.3  
2.1  
1.9  
4.1  
3.3  
1.9  
1.8  
2.7  
2.4  
8
65  
75  
75  
75  
75  
85  
75  
85  
75  
75  
75  
85  
98  
C44HLGP6100AASJ  
C44HLGR6200AASJ  
C44HLGR6300AASJ  
C44HLGR6400AASJ  
C44HLGR6500AASJ  
C44HLGR6600AASJ  
C44HKGR6100AASJ  
C44HKGR6133AASJ  
C44HKGR6133ZASJ  
C44HKGR6150AASJ  
C44HKGR6200AASJ  
C44HKGR6250AASJ  
6.1  
3.6  
3
2.7  
2.6  
5
4.5  
4
3.8  
3
117  
194  
242  
242  
242  
142  
142  
194  
194  
242  
242  
700  
1000  
1000  
1000  
1000  
1000  
1000  
20  
2.8  
Cap  
Value  
dV/dt  
(V/µs)  
Rth hs/amb  
ºC/W  
VAC  
VDC  
VDC  
Irms  
ESL  
Rs  
Case  
Part Number  
1 Maximum admissible RMS current THS ≤ 70°C.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
4
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
Lifetime Expectancy/Failure Quota Graphs  
Power Losses and Hot Spot Temperature Calculation  
At each frequency, the Power Losses are the sum of:  
1. Dielectric Power Losses  
Lifetime curve C44H series  
Hot Spot  
temperature  
[°C]  
1,40  
PD(fi) = 2 * π * fi* C * V(fi)2* tgδ0  
1,30  
≤60°C  
1,20  
which can be alternatively calculated as  
70°C  
1,10  
I(fi)2  
1,00  
PD(fi) =  
* tgδ0  
75°C  
2 * π * fi* C  
0,90  
0,80  
0,70  
0,60  
where: tgδ0 = 2 * 10-4  
2. Joule Power Losses:  
PJ(fi) = Rs * I(fi)2  
100  
1.000  
10.000  
100.000  
1.000.000  
Lifetime Expectancy [h]  
The Total Power Losses are the sum of the components at each frequency:  
P =  
T
[
P
(
fi  
)
+ P  
fi  
( )  
]
D
J
i
The Thermal Jump in the Hot Spot is:  
ΔTHS = PT * Rth-hs  
V = Operating Voltage [VAC]  
V
rms = Rated Voltage [VAC]  
The Hot Spot Temperature is:  
T
HS = Ta + ΔTHS  
FIT @ Hot Spot Temperatures  
Limits for the formulas  
75  
70  
≤60  
The limits listed below should not be exceeded:  
1.  
1000  
100  
10  
V ( f )2 V  
i
RMS  
RMS  
i
2.  
I( f )2 I  
i
i
T
HS =Ta + ΔTHS ≤ (THS )  
MAX  
Where Ta is the ambient temperature (steady state temperature of the  
cooling air flowing around the capacitor, measured at 100 mm of distance  
from the capacitor and at a height of 2/3 height of the capacitor).  
1
0,6  
0,7  
0,8  
0,9  
1
1,1  
Voltage Ratio [U/Urms]  
3. Maximum case temperature (TCASE) ≤ 70°C  
IRMS = √(13.82 + 272) = 30 ≤ 30 Admitted  
V
Example of calculation  
Part Number: C44HKGR6100AASJ  
RMS = √(4402 + 6.12) = 440 ≤ 440 Admitted  
PD(50) = 2 * π * 50 * 100 * 10-6 * 4402 * 2 * 10-4 = 1.22 [W]  
PD(7000) = [272/(2 * π * 7000 * 100 * 10-6)] * 2 * 10-4 = 0.03 [W]  
PJ(50) = 3.5 * 10-3 * [(2 *π * 50 * 100 * 10-6 * 440)2] = 0.67 [W]  
PJ(7000) = 3.5 * 10-3 * 272 = 2.55 [W]  
Rated VRMS = 440 [VRMS  
Rated IRMS = 30 [A]  
Rs = 4.1 [mΩ]  
]
Rth = 5.0 [°C/W]  
PT = 1.22 + 0.03 + 0.78 + 3 = 5 [W]  
ΔTHS = 5 * 5 = 25 [°C]  
THS = Ta + ΔTHS  
THS = 35 + 25 = 60 [°C] OK since hot spot temperature is less  
than maximum admitted  
Expected Life @ THS = 70°C 100,000 hours (see lifetime curve)  
Expected Life @ THS = 60°C 140,000 hours (see lifetime curve)  
Fundamental Frequency F1 = 50 [Hz]  
Ripple Frequency F2 = 7000 [Hz]  
Fundamental Voltage V1 = 440 [V~]  
Ripple Current I2 = 27 [A]  
Ta = 35°C  
I1 = I(50) = 2 * π * 50 * 100 * 10-6 * 440 = 13.8 [A]  
V2 = V(7000) = [27/(2 * π * 7000 * 100 * 10-6)] = 6.14 [V]  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
5
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
Marking  
Dissipation Factor  
Dissipation factor is a complex function involved with the inefficiency of the capacitor. The tgδ may change up and down  
with increased temperature. For more information, please refer to Performance Characteristics.  
Sealing  
Hermetically Sealed Capacitors  
When the temperature increases, the pressure inside the capacitor increases. If the internal pressure is high enough, it can  
cause a breach in the capacitor which can result in leakage, impregnation, filling fluid or moisture susceptibility.  
Resin Encased/Wrap & Fill Capacitors  
The resin seals on resin encased and wrap and fill capacitors will withstand short-term exposure to high humidity  
environments without degradation. Resins and plastic tapes will form a pseudo-impervious barrier to humidity and  
chemicals. These case materials are somewhat porous and through osmosis can cause contaminants to enter the capacitor.  
The second area of contaminated absorption is the lead-wire/resin interface. Since resins cannot bond 100% to tinned wires,  
there can be a path formed up to the lead wire into the capacitor section. Aqueous cleaning of circuit boards can aggravate  
this condition.  
Barometric Pressure  
The altitude at which hermetically sealed capacitors are operated controls the voltage rating of the capacitor. As the  
barometric pressure decreases, the susceptibility to terminal arc-over increases. Non-hermetic capacitors can be affected  
by internal stresses due to pressure changes. This can be in the form of capacitance changes or dielectric arc-over as well  
as low insulation resistance. Heat transfer can also be affected by altitude operation. Heat generated in operation cannot be  
dissipated properly and can result in high RI2 losses and eventual failure.  
Radiation  
Radiation capabilities of capacitors must be taken into consideration. Electrical degradation in the form of dielectric  
embitterment can take place causing shorts or opens.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
6
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
Environmental Compliance  
As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental  
effects of both our capacitors and their production.  
In Europe (RoHS Directive) and in some other geographical areas like China, legislation has been put in place to prevent the  
use of some hazardous materials, like Lead (Pb), in electronic equipment. All products in this catalog are produced to help  
our customers' obligations to guarantee their products to fulfill these legislative requirements. The only material of concern  
in our products has been Lead (Pb), which has been removed from all designs to fulfill the requirement of containing less  
than 0.1% of Lead in any homogeneous material.  
KEMET will closely follow any changes in legislation world wide and makes any necessary changes in its products, whenever  
needed.  
Some customer segments like Medical, Military and Automotive Electronics may still require the use of Lead in electrode  
coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels  
for RoHS compatible capacitors.  
Because of customer requirements there may appear additional markings like LF = Lead Free or LFW = Lead Free Wires on  
the label.  
All KEMET power film products are RoHS Compliant.  
Materials & Environment  
The selection of materials used by KEMET for the production of capacitors is the result of extensive experience and  
constant attention to environmental protection. KEMET selects its suppliers according to ISO 9001 standards and carries out  
statistical analysis on the materials purchased before acceptance. All materials are, to the company's present knowledge,  
non-toxic and free from Cadmium, Mercury, Chrome and compounds, PCB (Polychlorine Triphenyl), Bromide and Chlorine  
Dioxins Bromurate Clorurate, CFC and HCFC and Asbestos.  
Green Products  
All KEMET power film products are ROHS Compliant.  
Insulation Resistance  
When the capacitor temperature increases, the insulation resistance decreases. This is due to increased electron activity.  
Low insulation resistance can also be the result of moisture trapped in the windings, caused by a prolonged exposure to  
excessive humidity.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
7
Power and AC Film Capacitors – Aluminum Can Power Film Capacitors  
C44H Series, 330 – 440 VAC, 700 – 1,000 VDC, for PFC and AC Filter  
KEMET Electronic Corporation Sales Offices  
For a complete list of our global sales offices, please visit www.kemet.com/sales.  
Disclaimer  
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for  
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.  
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such  
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.  
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any  
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no  
obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component  
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards  
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or  
property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other  
measures may not be required.  
Prototype Sample Disclaimer  
The Customer acknowledges the following limitations of the prototype samples:  
(1) Prototype samples are manufactured from preliminary designs and manufacturing processes; may not represent final designs; have not been  
released for commercial use and are not subject to the same quality control procedures applicable to released products.  
(2) Prototype samples are not qualified parts and are provided “as-is” by KEMET Electronics Corporation, which specifically disclaims any and all  
warranties and guarantees, explicit or implied, including, without limitation, the warranties of merchantability and fitness for a particular purpose or use.  
(3) Prototype samples are not intended for commercial use; are provided for engineering evaluation only and are not recommended for use in the  
Customer’s production line.  
(4) The Customer assumes the risk ofany and alluses that the Customer makes of the prototype samples.  
General Disclaimer  
“All product specifications, statements, information and data given herein are believed to be accurate and reliable, but are presented without guarantee,  
warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on our knowledge of typical  
operating conditions for such applications, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitability for  
a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to  
determine the correct products for their application.  
KEMET’s product warranty is set forth at www.kemet.com under Terms and Conditions of Sale.”  
KEMET is a registered trademark of KEMET Electronics Corporation.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
F3054_C44H_RADIAL • 9/20/2016  
8

C44HKGP6100ZASJ 相关器件

型号 制造商 描述 价格 文档
C44HKGP6100ZASK KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HKGR6100AASJ KEMET Film Capacitor, Polypropylene, 1000V, 5% +Tol, 5% -Tol, 100uF, Stud Mount 获取价格
C44HKGR6100AASK KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HKGR6100ZASJ KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HKGR6100ZASK KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HLGP6100AASJ KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HLGP6100AASJ_17 KEMET Film, Metallized Polypropylene, AC Filter, C44H, 100 uF, 5%, 700 V, 330 V 获取价格
C44HLGP6100AASK KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HLGP6100ZASJ KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格
C44HLGP6100ZASK KEMET C44H Series, 330 - 440 VAC, 700 - 1,000 VDC, for PFC and AC Filter 获取价格

C44HKGP6100ZASJ 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6