C987U472JZSDAA7317
更新时间:2024-09-18 21:39:26
品牌:KEMET
描述:Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
C987U472JZSDAA7317 概述
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
C987U472JZSDAA7317 数据手册
通过下载C987U472JZSDAA7317数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated,
AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Overview
KEMET’s 900 Series encapsulated radial leaded ceramic
disc capacitors are specifically designed for interference-
suppression AC line filtering applications. Having interna-
tionally recognized safety certifications, these capacitors
are well-suited for applications that require keeping poten-
tially disruptive or damaging line transients and EMI out
of susceptible equipment. They are also an ideal solution
in situations where there is a need to suppress line distur-
bances at the source.
With a working voltage of 440 VAC in line-to-line (Class X)
and 300 VAC in line-to-ground (Class Y) applications, these
safety capacitors meet the impulse test criteria outlined in
IEC Standard 60384. Meeting subclass X1 and Y2 require-
ments, these devices are certified to withstand impulses up
to 4 KV (X1) and 5 KV (Y2) respectively. These encapsulated
devices also meet the flame test requirements outlined in UL
Standard 94V–0.
Safety Certified Capacitors are classified as either X and/or
Y capacitors. Class X capacitors are primarily used in line-to-
line (across-the-line) applications. In this application there is
no danger of electric shock to humans should the capacitor
fail, but could result in a risk of fire. The class Y capacitor is
primarily used in line-to-ground (line by-pass) applications. In
this application, failure of the capacitor could lead to danger
of electric shock.
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Ordering Information
C9
7
1
U
472
M
Z
W
D
A
A
7317
Ceramic
Series
Body
Diameter
Lead
Spacing1,2,4
Capacitance Capacitance Rated Dielectric/
Lead
Config.1,3,4
Failure Packaging
Spec.
Design
Code (pF)
Tolerance
Voltage Temp. Char.
Rate
(C-Spec)
C9 =
0 = 7.0 mm
7 = 7.5 mm
1 = 10.0
mm
U =
Two
J = ±5%
Z = X1 S = SL
440 VAC Y = Y5P
/Y2 300 W = Y5U
D = A = Straight
Disc B = Vertical
Kink
A =
N/A
See
"Packaging
C-Spec
Ordering
Options
Table"
Ceramic 1 = 8.0 mm
900 2 = 9.0 mm
Series 3 = 10.0 mm
4 = 11.0 mm
Safety significant K = ±10%
digits and M = ±20%
number of
VAC
V = Y5V
C = Outside
Kink
D = Inside
Kink
zeroes
6 = 13.0 mm
8 = 15.0 mm
below
1 Due to a high risk of arcing, "Inside Kink" lead configuration cannot be combined with the 5 mm lead spacing option. The "Inside Kink" option is only
available on capacitors with lead spacing of 7.5 mm or greater. A potential for arcing may exist when combining the "Inside Kink" lead configuration
with a 7.5mm lead spacing option, especially in high humidity environments and/or when exposure to voltages and transients may impact creepage and
clearance requirements.
2 Capacitor body diameter will limit available lead spacing and packaging options. See "Dimensions" and "Product Ordering Codes and Ratings" sections
of this document to determine availability.
3 "Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
4 Bulk packaging lead length availability is dependent upon "Lead Configuration" and "Lead Spacing." See "Dimensions" section of this document to
verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
1
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Packaging C-Spec Ordering Options Table
Lead Length
(mm)2,3
Packaging
Ordering Code (C-Spec)
Packaging Type
20.0+1.5/−1.0 (straight leads)
18.0+2.0/−0 (preformed leads1)
Ammo Pack
7317
3.0±1.0
3.5±1.0
WL30
WL35
WL40
WL45
WL50
WL20
4.0±1.0
Bulk Bag
4.5±1.0
5.0±1.0
20.0 minimum4
1 Preformed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"
sections of this document for further details.
2 "Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
3 For nonstandard lead length inquiries, please contact KEMET.
4 Lead length of 20.0 mm minimum only available for straight leads.
Benefits
• Safety Standard Recognized (IEC 60384–14)
• Reliable operation up to 125°C
• Class X1/Y2
• 7.5 mm and 10 mm lead spacing
• Lead (Pb)-free and RoHS Compliant
• Halogen free
• Capacitance offerings ranging from 10 pF up to 10 nF
• Available capacitance tolerances of ±5%, ±10% and ±20%
• High reliability
• Preformed (crimped) or straight lead configurations
• Non-polar device, minimizing installation concerns
• Encapsulation meets flammability standard UL 94V–0
Applications
Typical applications include:
• Line-to-line (Class X) filtering
• Line-to-ground (Class Y) filtering
• Antenna coupling
• Primary and secondary coupling (switching power supplies)
• Line disturbances suppression (motors and motor controls, relays, switching power supplies, and inverters)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
2
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Lead Configurations
Straight
Vertical Kink
Outside Kink
Inside Kink1
D
T
D
T
D
T
D
T
3ꢁ0
ꢂaꢃimum
3ꢁ0
ꢂaꢃimum
3ꢂ0
ꢃaꢄimum
3ꢂ0
ꢃaꢄimum
ꢁꢂ0 ꢃaꢄimum
4ꢁ0 ꢂaꢃimum
ꢁꢂ0 ꢃaꢄimum
LL
LL
LL
LL
ꢀ
ꢀ
ꢀ
ꢀ
S
S
S
S
1 Due to a high risk of arcing, the "Inside Kink" lead configuration option cannot be combined with 5 mm lead spacing ("S" dimension above). The "Inside
Kink" option is only available on devices with lead spacing of 7.5 mm or 10 mm.
Dimensions – Millimeters
S
D
T
e
ØF
Lead
Lead
Spacing
Tolerance
Lead
Configuration
Configuration
Lead
Body
Body
Thickness
Lead
Meniscus
Lead
Diameter
Ordering Code1
Spacing2
Diameter2
7.5
10.0
7.5
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
Straight
A
B
C
D
Vertical Kink
(Preformed)
See Table 1 -
"Product Ordering Codes
and Ratings"
10.0
7.5
3.0
maximum
0.55±0.1
Outside Kink
(Preformed)
10.0
7.5
Inside Kink
(Preformed)
10.0
1 Lead Configuration is identified in the 13th character of the ordering code. See "Lead Configuration" and "Ordering Information" sections of this
document for further details.
2 Body diameter of capacitor will limit available lead spacing and packaging options. See "Product Ordering Codes and Ratings" sections of this
document for further details.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
3
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Approval Standard and Certification No.
Safety Standard
Standard No.
Subclass
Working Voltage
440 VAC
Certificate No.
X1
Y2
X1
Y2
VDE
(ENEC)
IEC 60384–14
40036415
300 VAC
440 VAC
UL
CAN/CSA
UL 60384–14 and
E356389
E60384–14
300 VAC
These devices are VDE/ENEC and UL recognized for antenna coupling and AC line-to-line (Class X) and line-to-ground (Class Y) applications per
IEC60384–14 and UL 60384–14.
Environmental Compliance
These devices are Halogen free and RoHS Compliant. They meet all requirements set forth by both EU and China RoHS
directives.
General Specifications/Performance Characteristics
Dielectric/Temperature Characteristic
SL
Y5P
Y5U
Y5V
Operating Temperature Range:
−40°C to +125°C
Capacitance Change with Reference to +25°C
and 0 VDC Applied (TCC):
−1,000 ~ +350 ppm/
±10%
+20%/−55%
~ +30%/−80%
ºC
Dielectric Withstanding Voltage
(7.5 mm and 10 mm Lead Spacing)
2,600 VAC
(60±5 seconds at 25ºC)
30 pF and above:
≥ 1,000
Below 30 pF: ≥ 400
+(20xC)*
Quality Factor (Q)
See “Dissipation Factor”
Dissipation Factor (tanδ) at +25ºC1
2.50%
2.50%
5.0%
See “Quality Factor”
10,000 MΩ Minimum
(500 VDC applied for 60±5 seconds at 25°C)
Insulation Resistance (IR) Limit at +25°C
*C = Nominal capacitance
1 Capacitance and Dissipation Factor (DF) measured under the following conditions:
SL: 1 MHz ± 100 kHz and 1.0 ±0.2 Vrms
X5P, Y5U and Y5V: 1 kHz ± 50 Hz and 1.0 ±0.2 Vrms
Note: When measuring capacitance, it is important to ensure the set voltage level is held constant. The HP4284 and Agilent E4980 have a feature known
as Automatic Level Control (ALC). The ALC feature should be switched to "ON."
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
4
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 1 – Product Ordering Codes and Ratings
Dimensions (mm)
Lead Spacing
Dielectric/
Temp.
Char.
KEMET
Part Number
Capacitance
Tolerance
Body
Body
Thickness
Capacitance
Lead
Bulk
Ammo
Packaging
Diameter
Diameter Packaging
(Maximum) (Maximum)
C90(1)U100JZSD(2)A(3)
C90(1)U120JZSD(2)A(3)
C90(1)U150JZSD(2)A(3)
C90(1)U180JZSD(2)A(3)
C90(1)U200JZSD(2)A(3)
C90(1)U220JZSD(2)A(3)
C90(1)U240JZSD(2)A(3)
C90(1)U270JZSD(2)A(3)
C90(1)U300JZSD(2)A(3)
C90(1)U330JZSD(2)A(3)
C90(1)U360JZSD(2)A(3)
C90(1)U390JZSD(2)A(3)
C90(1)U470JZSD(2)A(3)
C90(1)U500JZSD(2)A(3)
C90(1)U510JZSD(2)A(3)
C91(1)U560JZSD(2)A(3)
C91(1)U620JZSD(2)A(3)
C91(1)U680JZSD(2)A(3)
C91(1)U750JZSD(2)A(3)
C92(1)U820JZSD(2)A(3)
C93(1)U101JZSD(2)A(3)
10 pF
12 pF
15 pF
18 pF
20 pF
22 pF
24 pF
27 pF
30 pF
33 pF
36 pF
39 pF
47 pF
50 pF
51 pF
56 pF
62 pF
68 pF
75 pF
82 pF
100 pF
7.0
7.5 mm
or
10 mm
SL
±5%
5.0
0.55 ±0.1
8.0
9.0
10.0
C90(1)U101KZYD(2)A(3)
C90(1)U151KZYD(2)A(3)
C90(1)U221KZYD(2)A(3)
C90(1)U331KZYD(2)A(3)
C90(1)U471KZYD(2)A(3)
C91(1)U561KZYD(2)A(3)
C91(1)U681KZYD(2)A(3)
C92(1)U821KZYD(2)A(3)
C92(1)U102KZYD(2)A(3)
100 pF
150 pF
220 pF
330 pF
470 pF
560 pF
680 pF
820 pF
1,000 pF
7.0
7.5 mm
or
10 mm
Y5P
±10%
5.0
0.55 ±0.1
8.0
9.0
C90(1)U102MZWD(2)A(3)
C92(1)U152MZWD(2)A(3)
C92(1)U222MZWD(2)A(3)
C94(1)U332MZWD(2)A(3)
C96(1)U392MZWD(2)A(3)
C96(1)U472MZWD(2)A(3)
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
7.0
9.0
7.5 mm or 10 mm
Y5U
±20%
±20%
5.0
0.55 ±0.1
7.5 mm or 10 mm
11.0
13.0
10 mm only
C90(1)U102MZVD(2)A(3)
C90(1)U152MZVD(2)A(3)
C90(1)U222MZVD(2)A(3)
C92(1)U332MZVD(2)A(3)
C94(1)U392MZVD(2)A(3)
C94(1)U472MZVD(2)A(3)
C96(1)U682MZVD(2)A(3)
C98(1)U103MZVD(2)A(3)
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
6,800 pF
10,000 pF
7.0
7.5 mm or 10 mm
9.0
Y5V
5.0
0.55 ±0.1
7.5 mm or 10 mm
11.0
13.0
15.0
10 mm only
Capacitance
Tolerance
Body Diameter
(Maximum)
Body Thickness
(Maximum)
KEMET Part Number
Capacitance
Lead Diameter
Lead Spacing
(1) To properly complete ordering code, insert the one-digit numeric code to reflect required lead spacing: (Note that select capacitance values and
packaging options may limit lead spacing availability. See table above to verify availability.)
7 = 7.5 mm
1 = 10.0 mm
(2) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section
of this document, page 2, for further details.)
A = Straight
B = Vertical Kink
C = Outside Kink
D = Inside Kink
(3) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of
this document, page 2, for available options.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
5
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions
Item
Specification
Test Method
−40ºC to +125ºC
Operating Temperature Range
Between lead
wires
The capacitor shall not be damaged when 2,600 VAC(rms) is
applied between the lead wires for 60 seconds.
No failures
The terminals (leads) of the capacitor
shall be connected together. A metal foil
is tightly wrapped around the body of the
capacitor at a distance of about 3 to 4 mm
Dielectric
Strength
ꢀetal
ꢁoil
Body Insulation
No failures
from each terminal. The capacitor is then
aꢃout
3 to 4 mm
inserted into a container filled with metal
balls approximately 1 mm in diameter. 2,600
VAC(rms) is applied for 60 seconds between
the capacitor lead wires and metal balls.
ꢀetal
ꢂalls
The insulation resistance shall be measured with 500±50 VDC
applied after 60±5 seconds of charging.
Insulation Resistance (IR)
10,000 MΩ minimum
Capacitance
Within specified tolerance
Temperature
Characteristics
Specification
Y5P, Y5U
Y5V
DF ≤ 2.5%
DF ≤ 5.0%
Y5P, Y5U and Y5V: Capacitance is measured at 1 kHz ±20% and 5
Vrms or less. (20±2°C)
SL: Capacitance is measured at 1 MHz ±20% and 1.0±0.2 Vrms
(25°C)
Dissipation Factor (DF) or Q
SL
≥ 30 pF: Q ≥ 1000
< 30 pF: Q ≥ 400
+(20 x C)
C = Nominal
capacitance
A capacitance measurement is made at each step specified:
Temperature
Characteristics
Capacitance
Change
Step
Temperature
+20±2ºC
1
Y5P
Y5U
Y5V
Within ±10%
2
−25±2ºC
Within +20%/−55%
3
+20±2ºC
Temperature Characteristics
Within
~+30%/−80%
4
+85±2ºC
+20±2ºC
5
SL
−1,000 ~+350
ppmºC
(+20ºC ~+85ºC)
Pre-treatment:
Capacitor is stored at 85±2ºC for 1 hour and then placed at room
condition1 for 24±2 hours before measurement.
With the termination in its normal position, the specimen is held
by its body in such a manner that the axis of the termination is
vertical; a tensile force of 10 N is applied to the termination in the
direction of its axis and acting in a direction away from the body
of the specimen.
Lead wire or capacitor body shall not
break.
Tensile
With the termination in its normal position, the specimen is held
by its body in such a manner that the axis of the termination is
vertical; a mass force of 5 N is then suspended from the end of
the termination. The body of the specimen is then inclined within
a period of 2 to 3 seconds, through an angle of approximately 90°
in the vertical plane and then resumed to its initial position over
the same period of time; this operation constitutes one bend.
One bend immediately followed by a second bend in the opposite
direction.
Terminal
Strength
Lead wire or capacitor body shall not
break.
Bending
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
6
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd
Item
Specification
Test Method
The lead wire of the capacitor is dipped into molten solder for
5±0.5 seconds. The depth of immersion is up to 1.5 mm
(+5/−0 mm) from the root of lead wires.
Solder Temperature: Lead free solder (Sn-3Ag – 0.5Cu)
245°C ±5°C.
Lead wire should have a uniform coating
of solder in the axial direction and over
3/4 of its circumference.
Solderability
As shown in the figure below, the lead wires are immersed in
molten solder up to 1.5 mm (+5/−0 mm) from the end of the
epoxy meniscus (root of lead wire).
Duration/Solder Temperature: 3.5±0.5 seconds/350°C ±10°C or
10±1 seconds/260°C ±5°C
Appearance
No visual defect
1,000 MΩ
IR
Dielectric
Strength
Per item 1
Tꢃermal
Screen
Capacitor
Soldering Effect
(Non-Preheat)
1ꢁꢂ to
2ꢁ0 mm
ꢀolten
Solder
Y5P, Y5U and Y5V: Within ±10%
SL: Within ±2.5% or ±0.25 pF, whichever
is larger.
Capacitance
Pre-treatment: Capacitor is stored at 85°C ±2°C for 1 hour and
then placed at room condition1 for 24 ±2 hours before initial
measurements.
Post-treatment: Capacitor is stored for 1 to 2 hours at room
condition1.
Capacitor is stored at 120°C +0/−5°C for 60 +0/−5 seconds.
Then, as shown in the figure below, the lead wires are immersed
in molten solder up to 1.5 mm (+5/-0mm) from the end of the
epoxy meniscus (root of lead wire).
Appearance
No visual defect
1,000 MΩ
IR
Dielectric
Strength
Per item 1
Duration/Solder Temperature: 7.5 +0/−1 seconds/260°C ±5°C
Tꢃermal
Screen
Capacitor
Soldering Effect
(Preheat)
1ꢁꢂ to
2ꢁ0 mm
ꢀolten
Solder
Y5P, Y5U and Y5V: Within ±10%
SL: Within ±2.5% or ±0.25 pF, whichever
is larger.
Capacitance
Appearance
Pre-treatment: Capacitor is stored at 85°C ±2°C for 1 hour and
then placed at room condition1 for 24 ±2 hours before initial
measurements.
Post-treatment: Capacitor is stored for 1 to 2 hours at room
condition1.
No visual defect
Steady State Humidity:
Load Humidity:
Temperature
Characteristics
Capacitance
Change
Y5P
Y5U
Y5V
SL
Within ±10%
Within ±20%
Within ±30%
Capacitance
90 to 95% humidity at 40°C
±2°C for 500 ±12 hours with
full rated voltage applied.
Within ±2.5% or
±0.25 pF, whichever
is larger.
90 to 95% humidity at 40°C
±2°C for 500 ±12 hours.
Biased Humidity
Post Treatment:
Post Treatment:
Y5P and Y5U: 5.0% maximum
Capacitor is stored for 1 to 2
DF
Q
Capacitor is stored for 1 to 2
Y5V: 7.5% maximum
SL: Less than 30 pF:
hours at room condition1.
hours at room condition1.
Q ≥ 100 + 10 × C/3
More than 30 pF: Q ≥ 200
C = Nominal capacitance
Y5P, Y5V and Y5U: 3,000 MΩ minimum
SL: 1,000 MΩ minimum
IR
Dielectric
Strength
No failures
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
7
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd
Item
Specification
Test Method
Impulse Voltage: Each individual capacitor is subjected to three 5
No visual defect
Appearance
kv impulses prior to life testing.
Y5P, Y5V and Y5U: Within ±20%
SL: Within ±3 or ±0.3 pF,
whichever is larger.
Capacitance
Change
Cꢀ tr td
ꢀꢀR
Vp
(uꢀ) (uS) (uS)
0ꢀ01 1ꢀ2 4ꢀ
0ꢀ1 1ꢀꢁ 4ꢀ
0ꢀ9Vp
ꢀꢀꢀ
3,000 MΩ minimum
SL: 1,000 MΩ minimum
IR
0ꢀꢁVp
High
Temperature
Life
tr
td
Dielectric
Strength
Time
No failures
Capacitors are placed in a circulating air oven for a period of
1,000 hours. The air in the oven is maintained at a temperature of
125°C ±2 throughout the test. The capacitors are subjected to AC
510 Vrms. Each hour the voltage is increased to 1,000 Vrms for
0.1 seconds.
The capacitor is exposed to a flame for 15 seconds and then
The capacitor flame extinguishes as
follows:
removed for 15 seconds. This test is repeated for 5 cycles.
Capacitor
ꢂlame
Cycle
Time
ꢀꢁ
Flame Test
30 seconds
maximum
3ꢃ
1 ~ 4
12ꢀ
60 seconds
maximum
Gas ꢅurner
5
20ꢄ
(ꢆnitꢇmm)
The capacitors are individually wrapped in at least one, but not
more than two, complete layers of cheesecloth. They are then
subjected to 20 discharges. The interval between successive
discharges is 5 seconds. The VAC is maintained for 2 minutes
after the last discharge.
ꢀ
L1
L2
R
S1
C1
Vac
C2
L3
C3 CX
L4
Ct
Vt
S2
Tr
ꢁscilloscope
C1, 2
L1-4
R
1 μF ±10%
C3
0.033 μF ±5% 10 kV
Test capacitor
VR ±5%
Active Flammability
The cheesecloth should not ignite.
1.5 Mh ±20% 16A Rod core choke
100±2%
Cx
VAC
VR
Ct
F
3 μF ±5% 10 kV
Rated Voltage
Voltage applied to Ct
Fuse, Rated 10A
Vt
Vꢀ
ꢁꢂV
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
8
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd
Item
Specification
Test Method
The capacitor under test is held into a flame and in a position
which best promotes burning. Each specimen is exposed to the
flame one time.
Test Specimen
200
ꢀꢁmm
4ꢁꢄ
Tissue
The burning time should not exceed 30
seconds.
The tissue paper should not ignite.
Passive Flammability
Aꢂout 10mm
Tꢅicꢆ ꢇoard
Time of exposure to flame:
Length of flame:
30 seconds
12±1 mm
35 mm minimum
0.5±0.1 mm
Gas burner length:
Inside diameter:
Outside diameter:
Gas butane gas purity:
0.9 mm maximum
95% minimum
Appearance
No visual defect
Temperature
Characteristics
Capacitance
Change
The capacitor is subjected to 5 temperature cycles.
Temperature Cycle
Dwell
SL
Y5P
Within ±5%
Within ±10%
Within ±20%
Capacitance
Transition
Time
Step Temperature (°C)
Time
Y5U, Y5V
(minutes) (minutes)
1
2
3
4
−40+0/−3
Room temperature
125+3/−0
30
SL
≥ 30 pF: Q ≥ 350
< 30 pF: Q ≥ 275
+5/2C
C = Nominal
capacitance
Temperature
3
Cycle
3
30
DF/Q
IR
Room temperature
3
Y5P
DF ≤ 5%
Pre-treatment: Capacitor shall be stored at 85±2 for 1 hour then
placed at room condition1 for 24±2 hours.
Post-treatment: Capacitor is stored for 1 to 2 hours at room
condition1.
Y5U, Y5V
DF ≤ 7.5%
3,000 MΩ minimum
No failures
Dielectric
Strength
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017
9
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Soldering and Mounting Information
Soldering:
When soldering this product to a PCB/PWB, do not exceed the solder heat resistance specification of the capacitor.
Subjecting this product to excessive heating could reflow the solder joint between the lead and ceramic element and/or may
result in thermal shocks that can crack the ceramic element.
When soldering these capacitors with a soldering iron, it should be performed under the following conditions:
• Temperature of iron-tip: 400ºC maximum
• Soldering iron wattage: 50 W maximum
• Soldering time: 3.5 seconds maximum
Cleaning (ultrasonic cleaning):
To perform ultrasonic cleaning, observe the following conditions:
• Rinse bath capacity: Output of 20 watts per liter or less
• Rinsing time: 5 minute maximum
• Do not vibrate the PCB/PWB directly
• Excessive ultrasonic cleaning may lead to fatigue destruction of the lead wires
Construction
Detailed Cross Section
Epoꢀy Encapsulation
(0ꢁ4 mm ꢂinimum Tꢃicꢄness,
ꢅigment ꢆ ꢇlue/ꢈL 94 Vꢉ0)
Lead Attacꢃ Solder
(Sn9ꢊꢁꢋ/Ag3/Cu0ꢁꢋ)
Dielectric
ꢂaterial (ꢇaTiꢒ3)
Electrode
Electrode
(Ag ꢌ Glass ꢍrit)
(Ag ꢌ Glass ꢍrit)
Lead ꢑire
Lead Attacꢃ Solder
(Sn9ꢊꢁꢋ/Ag3/Cu0ꢁ
Steel
Core ꢂetal
Dielectric
ꢂaterial
(ꢇaTiꢒ3)
Cu
ꢇarrier Layer
100ꢎ Sn
(3ꢉꢏ ꢐm)
ꢍinisꢃ Layer
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 10
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Marking
These capacitors shall be stamped or laser marked with KEMET's trademark, type designation, capacitor class, rated voltage,
rated capacitance and capacitance tolerance codes. In addition, all devices are marked with the recognized approval mark
and a date/lot code for traceability. Marking will be supplied either on one side or both sides of the encapsulated capacitor
body. All marking shall be legible to allow for clear identification of the component. Marking appears in legible contrast.
Illustrated below is an example of the marking format and content. (Two sided marking is limited to capacitors with body
diameters ≤ 8.0 mm.)
Single Sided
Rated Capacitance
(3 Numeric Characters)
KEMET ID
Type Designation
(2 Characters)
Capacitance Tolerance Code
(1 Character)
VDE & ENEC
approval marks
IEC 60384-14 3rd
(2005)
Capacitor Class
and Rated Voltage
UL approval mark
Date/Lot Code
(See Table Below)
Double Sided
Front
Back
UL approval mark
Rated Capacitance
(3 Numeric Characters)
KEMET ID
Capacitance
Tolerance Code
(1 Character)
Type Designation
(2 Characters)
VDE & ENEC
approval marks
IEC 60384-14 3rd
(2005)
Capacitor Class
and Rated Voltage
Date/Lot Code
(See Table Below)
Date/Lot Code Explanation
6
C
6
1234
Manufacturing
Month:
Last digit of year,
e.g.,
Manufacturing
Location Code
Last 4 digits of
1-9 = Jan - Sept
A = October
N = November
D = December
lot no.
6 = 2016
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 11
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Packaging Quantities
Ammo Pack (Carrier Tape)
Component pitch on carrier tape2
Capacitor
Body Diameter
(mm)
Body Diameter
Code1
Bulk Bag
(Loose)
12.7 mm
15 mm
25.4 mm
7.0
8.0
0
1
2
3
4
5
6
7
8
9.0
1,000 pieces/box
10.0
11.0
12.0
13.0
14.0
15.0
500 pieces/bag
1,000 pieces/box
500 pieces/box
1 The "Body Diameter Code" is located in the third character position of the ordering code. This code identifies the maximum diameter of the capacitor
body in millimeters. For more information regarding the ordering code, see "Ordering Information" section of this document.
2 For details regarding component pitch on carrier tape, see "Ammo Pack Taping Format" and "Ammo Pack Taping Specifications" sections of this
document.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 12
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Figure 1 - Ammo Pack Taping Format
5 mm and 7.5 mm Lead Spacing:
∆S
ꢀ2
ꢀ
D
e
ꢄd
ꢀ1
ꢂ2
ꢂ0
ꢁ
ꢃ0
∆ꢃ1 0 ∆ꢃ2
T maꢀimum
ꢁarꢂing Side
L
ꢂ1
ꢂ
ℓ
ꢄD0
ꢀ0
10 mm Lead Spacing:
∆S
ꢀ2
ꢀ
D
t2
t1
e
ꢀ1
ꢂ2
ꢂ0
ꢁ
ꢄd
ꢃ0
L
ꢂ1
ꢂ
ꢀ0
ꢄD0
ℓ
Table 3 – Ammo Pack Taping Specifications
Lead Spacing
5 mm
7.5 mm
10 mm
Lead Style
Item
Straight
Preformed1
Straight
Preformed1
Straight
Preformed1
Symbol
Dimensions (mm)
Lead Spacing
Component Pitch
Sprocket Hole Pitch
F
P
5.0+0.8/−0.2
7.5±1.0
15.0
10.0±1.0
12.7
25.4±2
P0
12.7±0.3
15.0±0.3
12.7±0.3
Sprocket Hole Center to
P2
P1
6.35±1.5
3.75±1.0
7.5±1.5
12.7±1.5
7.7±1.5
Component Center
Sprocket Hole Center to Lead
3.75±1.0
Center
Body Diameter
Component Alignment (side/side)
Carrier Tape Width
D
∆S
W
See "Product Ordering Codes and Ratings" section of this document.
0±2.0
18.0+1.0/−0.5
1 Prefromed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"
sections of this document for further details.
2 Also referred to as "lead length" in this document.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 13
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 3 – Ammo Pack Taping Specifications cont'd
Lead Spacing
5 mm
7.5 mm
10 mm
Lead Style
Item
Straight
Preformed1
Straight
Preformed1
Straight
Preformed1
Symbol
Dimensions (mm)
Sprocket Hole Position
W1
9.0±0.5
Height to Seating Plane2
(preformed leads1)
H0
H
N/A
18.0+2.0/−0
N/A
20.0+1.5/−1.0
18.0+2.0/−0
N/A
18.0+2.0/−0
Height to Seating Plane2
(straight leads)
20.0+1.5/−1.0
N/A
N/A
20.0+1.5/−1.0
N/A
Lead Protrusion
Diameter of Sprocket Hole
Lead Diameter
ℓ
D0
φd
t1
2.0 maximum
4.0±0.2
0.55±0.1
0.6±0.3
Carrier Tape Thickness
Total Thickness (Carrier Tape,
Hold-Down Tape and Lead)
t2
1.5 maximum
∆h1
∆h2
L
Component Alignment (front/
back )
2.0 maximum
11.0 maximum
Cut Out Length
Hold-Down Tape Width
Hold-Down Tape Position
W0
W2
11.0 minimum
3.0 maximum
11.5 minimum
1.5±1.5
1 Prefromed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"
sections of this document for further details.
2 Also referred to as "lead length" in this document.
Application Notes:
Storage and Operating Conditions:
The insulating coating of these devices does not form an air and moisture-tight seal. Avoid exposure to moisture and do not
use or store these devices in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt, or the like
are present. Before cleaning, bonding or molding these devices, it is important to verify that your process does not affect
product quality and performance. KEMET recommends testing and evaluating the performance of a cleaned, bonded or
molded product prior to implementing and/or qualifying any of these processes. Store the capacitors where the temperature
and relative humidity do not exceed 40 degrees Centigrade and 70% respectively. For optimum solderability, capacitor stock
should be used promptly, preferably within 6 months of receipt.
Working Voltage:
Application voltage (Vp-p or Vo-p) must not exceed the voltage rating of the capacitor. Irregular voltages can be generated
for a transient period of time when voltage is initially applied and/or removed from a circuit. It is important to choose a
capacitor with a voltage rating greater than or equal to these irregular voltages.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 14
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Operating Temperature and Self-Generating Heat:
The surface temperature of a capacitor should be kept below the upper limit of its rated operating temperature range. Be
sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current,
pulse current or similar current, it may self-generate heat due to dielectric loss. Temperature rise due to self-generated
heating should not exceed 20°C (while operated at an atmosphere temperature of 25°C).
Handling - Vibration and Impact:
Do not expose these devices or their leads to excessive shock or vibration during use.
FAILURE TO FOLLOW THE ABOVE CAUTIONS MAY RESULT, WORST CASE, IN A SHORT CIRCUIT AND CAUSE FUMING OR
PARTIAL DISPERSION WHEN THE PRODUCT IS USED.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 15
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
KEMET Electronic Corporation Sales Offices
For a complete list of our global sales offices, please visit www.kemet.com/sales.
Disclaimer
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 16
C987U472JZSDAA7317 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
C987U472JZSDBA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZSDCA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZSDDA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZVDAA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZVDBA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZVDCA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZVDDA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZWDAA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZWDBA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 | |
C987U472JZWDCA7317 | KEMET | Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade) | 获取价格 |
C987U472JZSDAA7317 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6