SC-04-D050 [KEMET]

General Purpose Inductor,;
SC-04-D050
型号: SC-04-D050
厂家: KEMET CORPORATION    KEMET CORPORATION
描述:

General Purpose Inductor,

电感器
文件: 总6页 (文件大小:580K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC Line Filters  
SC Coils, SC-D High Frequency Type  
Overview  
Applications  
TheꢀKEMETꢀSCꢀCoils,ꢀSC-DꢀHighꢀFrequencyꢀTypeꢀACꢀlineꢀfiltersꢀ  
areꢀofferedꢀinꢀaꢀwideꢀvarietyꢀofꢀsizesꢀandꢀspecifications.  
• Consumer Electronics  
• Common mode choke  
Benefits  
•ꢀ Wideꢀvarietyꢀofꢀsizesꢀandꢀspecifications  
• Inductances up to 100 mH  
• Rated Currents up to 20 A  
•ꢀ DCꢀResistancesꢀasꢀlowꢀasꢀ8ꢀmΩ  
Part Number System  
SC-  
Series  
SC-  
10-  
D
050  
Rated Current (A)  
Type  
Minimum Inductance (µH)  
0x = x A (e.g., 05 = 5 A)  
xx = xx A (e.g., 10 = 10 A)  
D = Ni-Zn ferrite core, high frequency xxx = xxx mH (e.g., 100 = 100 mH)  
0xx = xx mH (e.g., 060 = 60 mH)  
One world. One KEMET  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
1
AC Line Filters – SC Coils, SC-D High Frequency Type  
Dimensions – Millimeters  
Vertical Type (≤ 5 A)  
Horizontal Type (≥ 8 A)  
OD  
T
OD  
(a)  
15 ±2.0  
T
1
3
2
4
1 3 4 2  
(a)  
(b)  
Mounting Pitch  
(a)  
2
1
4
3
Environmental Compliance  
All KEMET AC Line Filters are RoHS Compliant.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
2
AC Line Filters – SC Coils, SC-D High Frequency Type  
Table 1 – Ratings & Part Number Reference  
Pin Pitch1  
DC  
Finished  
Dimensions (mm) (reference)  
Rated Inductance  
Temperature  
Rise (K)  
Maximum  
Wire  
Diameter  
(mm)  
Resistance/  
Line (mΩ)  
Maximum  
Weight (g)  
Approximate  
Part Number Current  
(µH)  
OD  
(Maximum)  
T
AC (A) Minimum  
a
b
(Maximum)  
SC-02-D100  
SC-03-D050  
SC-04-D050  
SC-05-D030  
SC-08-D060  
SC-10-D050  
SC-15-D030  
SC-20-D010  
2
3
4
5
8
10  
15  
20  
100  
50  
50  
30  
60  
50  
30  
10  
70  
40  
25  
20  
30  
16  
12  
8
40  
40  
40  
40  
45  
45  
50  
50  
23  
23  
25  
25  
34  
34  
34  
34  
13  
13  
19  
19  
23  
23  
23  
23  
10  
10  
10  
10  
22  
22  
22  
22  
13  
13  
19  
19  
21  
21  
21  
21  
0.5  
0.5  
0.7  
0.8  
1.0  
1.2  
1.4  
1.7  
7
8
14  
14  
30  
34  
34  
33  
1 Pin pitch listed above for reference only. Values not guaranteed.  
SC-  
10-  
D
050  
Series  
Rated Current (A)  
Type  
Minimum Inductance (µH)  
S
SC-  
0x = x A (e.g., 05 = 5 A)  
xx = xx A (e.g., 10 = 10 A)  
D = Ni-Zn ferrite core, high frequency xxx = xxx mH (e.g., 100 = 100 mH)  
0xx = xx mH (e.g., 060 = 60 mH)  
R
Withstanding Voltage  
Insulation Resistance  
Thermal Class  
2400 V (2 seconds, between lines)  
>ꢀ100ꢀMΩꢀ@ꢀ500ꢀVDCꢀ(betweenꢀlines)  
A (105°C)  
Operating Temperature Range  
-25ºC to T (T = 105 - temperature rise)  
100 kHz, 1 mA, KC547  
Inductance Measurement Condition  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
3
Roll Over for  
Order Info.  
AC Line Filters – SC Coils, SC-D High Frequency Type  
Frequency Characteristics  
1M  
1
1M  
100k  
10k  
1k  
1
6
3
6
3
03-D050  
100K  
1
1
6
3
08-D060  
6
3
04-D050  
10K  
1
6
3
1
6
3
10-D050  
1K  
1
1
6
3
02-D100  
6
3
15-D030  
100  
100  
10  
1
6
3
1
6
3
05-D030  
20-D010  
10  
1
6
3
1
6
3
3
6
1
3
6
1
3
6
1
3
6
1
3
3
6
1
3
6
1
3
6
1
3
6
1
3
1
1
1K  
10K  
100K  
1M  
10M 30M  
1k  
10k  
100k  
1M  
10M 30M  
Frequency (Hz)  
Frequency (Hz)  
Notes on Use  
Shelf Life  
Useꢀwithinꢀ6ꢀmonths.ꢀIfꢀtheꢀproductꢀisꢀusedꢀafterꢀaꢀstorageꢀperiodꢀofꢀ6ꢀmonthsꢀorꢀlonger,ꢀconfirmꢀitsꢀsolderabilityꢀbeforeꢀuse.  
Storage Condition  
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external  
electrode.  
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the  
solderability of external electrode.  
Avoidꢀstorageꢀnearꢀstrongꢀmagneticꢀfield,ꢀasꢀsuchꢀconditionꢀmayꢀmagnetizeꢀtheꢀproduct.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
4
AC Line Filters – SC Coils, SC-D High Frequency Type  
KEMET Corporation  
World Headquarters  
Europe  
Asia  
Southern Europe  
Paris, France  
Tel: 33-1-4646-1006  
Northeast Asia  
Hong Kong  
Tel: 852-2305-1168  
2835 KEMET Way  
Simpsonville, SC 29681  
Sasso Marconi, Italy  
Tel: 39-051-939111  
Shenzhen, China  
Tel: 86-755-2518-1306  
Mailing Address:  
P.O. Box 5928  
Greenville, SC 29606  
Beijing, China  
Central Europe  
Landsberg, Germany  
Tel: 49-8191-3350800  
Tel: 86-10-5829-1711  
www.kemet.com  
Tel: 864-963-6300  
Fax: 864-963-6521  
Shanghai, China  
Tel: 86-21-6447-0707  
Kamen, Germany  
Tel: 49-2307-438110  
Corporate Offices  
Fort Lauderdale, FL  
Tel: 954-766-2800  
Taipei, Taiwan  
Tel: 886-2-27528585  
Northern Europe  
Bishop’s Stortford, United Kingdom  
Tel: 44-1279-460122  
North America  
Southeast Asia  
Singapore  
Southeast  
Tel: 65-6586-1900  
Lake Mary, FL  
Tel: 407-855-8886  
Espoo, Finland  
Tel: 358-9-5406-5000  
Penang, Malaysia  
Tel: 60-4-6430200  
Northeast  
Wilmington, MA  
Tel: 978-658-1663  
Bangalore, India  
Tel: 91-806-53-76817  
Central  
Novi, MI  
Tel: 248-994-1030  
West  
Milpitas, CA  
Tel: 408-433-9950  
Mexico  
Guadalajara, Jalisco  
Tel: 52-33-3123-2141  
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not  
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of  
KEMET Electronics Corporation.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
5
AC Line Filters – SC Coils, SC-D High Frequency Type  
Disclaimer  
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market  
and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin.  
Allꢀproductꢀspeci ꢀcations,ꢀstatements,ꢀinformationꢀandꢀdataꢀ(collectively,ꢀtheꢀ“Information”)ꢀinꢀthisꢀdatasheetꢀareꢀsubjectꢀtoꢀchange.ꢀTheꢀcustomerꢀisꢀresponsibleꢀforꢀcheckingꢀandꢀ  
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.  
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
StatementsꢀofꢀsuitabilityꢀforꢀcertainꢀapplicationsꢀareꢀbasedꢀonꢀKEMETꢀElectronicsꢀCorporation’sꢀ(“KEMET”)ꢀknowledgeꢀofꢀtypicalꢀoperatingꢀconditionsꢀforꢀsuchꢀapplications,ꢀbutꢀareꢀ  
notꢀintendedꢀtoꢀconstituteꢀ–ꢀandꢀKEMETꢀspeci ꢀcallyꢀdisclaimsꢀ–ꢀanyꢀwarrantyꢀconcerningꢀsuitabilityꢀforꢀaꢀspeci ꢀcꢀcustomerꢀapplicationꢀorꢀuse.ꢀTheꢀInformationꢀisꢀintendedꢀforꢀuseꢀonlyꢀ  
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise  
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still  
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective  
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not  
be required.  
Digitally signed by Marcy Brand  
DN: c=US, st=FL, l=Fort Lauderdale, o=KEMET Corporation, ou=Marketing Communications, cn=Marcy Brand, email=marcybrand@kemet.com  
Date: 2013.08.28 13:27:05 -04'00'  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com  
LF0013_SC-D • 8/23/2013  
6

相关型号:

SC-04-E17J

Common Mode SC Coils, SC-J Series, Terminal Base Type
KEMET

SC-04-E2000

Common Mode SC Coils, Standard Series
KEMET

SC-04-E50J

Common Mode SC Coils, SC-J Series, Terminal Base Type
KEMET

SC-05-06J

Common Mode SC Coils, SC-J Series, Terminal Base Type
KEMET

SC-05-100

AC Line FIlters
NEC

SC-05-100

Common Mode SC Coils, Standard Series
KEMET

SC-05-100J

SINGLE PHASE EMI FILTER,
KEMET

SC-05-100JV

AC Line FIlters
NEC

SC-05-103

Common Mode SC Coils, Standard Series
KEMET

SC-05-10J

AC Line FIlters
NEC

SC-05-10J

Common Mode SC Coils, SC-J Series, Terminal Base Type
KEMET

SC-05-1100

Common Mode SC Coils, Standard Series
KEMET