USEQFCEA448100 [KEMET]
QFCE Pyroelectric Infrared Flame Sensors, I2C-TO;型号: | USEQFCEA448100 |
厂家: | KEMET CORPORATION |
描述: | QFCE Pyroelectric Infrared Flame Sensors, I2C-TO |
文件: | 总7页 (文件大小:563K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Flame Sensors
QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Overview
Applications
KEMET’sꢀQFCEꢀpyroelectricꢀflameꢀsensorsꢀcombineꢀhighꢀ
• Industrial
sensitivityꢀwithꢀfastꢀresponseꢀtimesꢀandꢀhighꢀdynamicꢀrangeꢀ • Industrial IoT
toꢀensureꢀrapidꢀandꢀaccurateꢀdetectionꢀofꢀsmallꢀandꢀlargeꢀ
flames,ꢀnearbyꢀorꢀoverꢀlargerꢀdistances.
• Oil and gas
•ꢀ Infrastructureꢀprotection
• Forest protection
• Smart home
•ꢀ Smartꢀbuilding
•ꢀ Outdoorꢀfireꢀdetectors
These high quality sensors, in their industry standard TO-39
package,ꢀintegrateꢀaꢀdigital,ꢀcurrentꢀmodeꢀread-outꢀofferingꢀ
highꢀresponsivityꢀoverꢀtheꢀfullꢀfrequencyꢀrangeꢀofꢀflameꢀ
flickerꢀfromꢀ3ꢀ-ꢀ30ꢀHz.ꢀIndustryꢀstandardꢀI2Cꢀcommunicationꢀ • Transportation
enablesꢀplug-and-playꢀconnectivityꢀtoꢀmicrocontrollersꢀandꢀ
allowsꢀeasyꢀtuningꢀandꢀcalibration.ꢀProgrammableꢀgainꢀandꢀ
filteringꢀofferꢀmaximumꢀflexibilityꢀinꢀsystemꢀdesign.
• Water cannon
Theirꢀlongꢀandꢀmaintenance-freeꢀoperationalꢀlifetimeꢀandꢀ
variousꢀlowꢀpowerꢀmodesꢀmakeꢀtheseꢀsensorsꢀidealꢀforꢀanyꢀ
smartꢀorꢀIoTꢀtypeꢀofꢀapplications.
Forꢀadditonalꢀsourcesꢀofꢀinformation,ꢀpleaseꢀreferꢀtoꢀ
https://ec.kemet.com/environmental-sensors/
Benefits
• Exceptionally high responsivity
•ꢀ Wideꢀfieldꢀofꢀview,ꢀtypicallyꢀ100°ꢀ(subjectꢀtoꢀfilterꢀband
passꢀspecification)
•ꢀ Rapidꢀrecoveryꢀfromꢀthermalꢀandꢀelectricalꢀshockꢀ(<1
secondꢀdowntime)
• TO39 package
• Digital output and I2C communication
•ꢀ Programmableꢀgainꢀandꢀfiltering
•ꢀ Variousꢀopticalꢀfilterꢀoptions
•ꢀ Integratedꢀconfigurableꢀamplifier,ꢀfilterꢀandꢀADC
• Low power comsumption
•ꢀ EvaluationꢀkitꢀforꢀdigitalꢀTOꢀinfraredꢀflame
sensing evaluation
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
1
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Ordering Information
USE
QFC
E
A
3911
0
0
Product
Family
Series
Sensor Type
Mounting Type
Specification
Packaging
0 = Bulk
Version
0
Sensors
QFC =
TO39 IR
Flame
E = Serial output,
digital
K = Evaluation kit
A = Sensor Only
9 = Evaluation Kit
Type 9
0000 = Fixed
3911ꢀ=ꢀ3.91ꢀµmꢀbandpass
4481ꢀ=ꢀ4.48ꢀµmꢀbandpass
4551ꢀ=ꢀ4.55ꢀµmꢀbandpass
5001 = 5.0 µm cut on
Sensors
Environmental Compliance
AllꢀKEMETꢀFlameꢀSensorsꢀareꢀRoHSꢀandꢀREACHꢀCompliant.
Article 33(1) of the REACH Regulation states that manufacturers and importers of articles (products) are required to notify
their customers of the presence of any Substances of Very High Concern (SVHC) in their products exceeding 0.1% by weight
and provide instructions on safe use of the product.
KEMET Corporation reports regarding the Article 33(1) of REACH Regulation as follows:
1. Applicable Product: Flame Sensors (QFC, QFCE, QFS & QFSM series)
2. Report for the content of REACH SVHC list:
The product(s) above contains a substance by more than 0.1wt% per product weight that was published in the 8th update of
the REACH SVHC substances (December 19, 2012).
3. Regarding the safety of the flame sensors (Piezoceramic products):
The Piezoceramic that is used in this product becomes ceramic by sintering powder containing PZT as the main ingredient. It
is chemically stable, with minimum risks toward the human body or environment within the intended use of the product. Please
note that risks could occur in the case of inhalation or accidental oral uptake of powder ceramics.
4. Technical product information on the flame sensors (Piezoceramic products):
The manufacturing technique of the “piezoceramic products” whose main ingredient is Lead Titanium Zirconium Oxide (PZT)
has been established, and there is no alternative material that can exhibit superior performance than PZT at this moment.
Please note that the piezoceramic is listed as an exempt on RoHS (2011/65/EU) AnnexIII (7c.1).
5. The responsibility of piezoceramic manufacturers:
Piezoceramic manufacturers report information regarding PZT containment in their products to the customers to obey the
article 33 of the REACH regulation
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
2
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Dimensions – Millimeters
Cross Section View
Filter
Top View
Sensor Pixel
Sensor Die
Sensor Die
5.2 ±0.1
StandꢀOffꢀonꢀGNDꢀPinꢀ
1.96
0.38 Maximum
Bottom View
SCL
GND
Φ 0.43 +0.06, -0.025
Φꢀ9.14 +0.05, -0.06
(Notꢀtoꢀscale)
Dimensions are typical, unless tolerance stated.
V+
SDA
Recommended Circuit Diagram
Single Device Block Diagram
CS
Digital Filter
FIFO
Timing Ctrl
Interrupt Ctrl
Wake-up
INT
SDA
SCL
M
C
U
15b
Analog
∆Σ
Front-End
ADC
CLK
SYNC
Reference/Regulator
VCC (1.8 - 3.6 V)
Clock Generator
VDD
GND
>100 nF
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
3
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Field of View
FoV across horizontal
window aperture
FoV across vertical
window aperture
FoV across diagonal
window aperture
Note: Normalised polar plots show typical FoV along x, y axis and diagonal with 4.48 μm/620 nm filter applied, with infrared source being a blackbody
radiator at 500 K temperature.
Performance Characteristics
Signal Filtering & Power Modes
Fixed
Analog Low
Pass Filter
(Hz)
Fixed
Digital Low
Pass Filter
(Hz)
Maximum
ADC
Sampling Rate
(sps)
Power Mode
(Base Sample
Rate)
Digital Low
Pass Filter
(Hz)
High Pass Filter – Analog
(Hz)
NormalꢀPowerꢀMode
Off
Off
1.0
2.0
4.0
8.0
600
250
180.0 90.0 45.0 22.5
30.00 15.00 7.50 3.75
1,000
Low Power Mode
0.17 0.33 0.66 1.30
100
42
166
Typical Current
Consumption
Item
Mode
Description
(1.8 V, Room Temperature)
NormalꢀPowerꢀMode
Normalꢀpowerꢀconsumption,ꢀ1ꢀkHzꢀmaximumꢀsampleꢀrate
Lowꢀpowerꢀconsumption,ꢀ166ꢀHzꢀmaximumꢀsampleꢀrate
Sensor signal readout over I2C
22 µA
3.5 µA
22 µA
Power Consumption
Low Power Mode
NormalꢀOperationꢀMode
Sleep Mode
21ꢀµAꢀ(NormalꢀPowerꢀMode)
3.5ꢀµAꢀ(LowꢀPowerꢀMode)
Operational State
Hardwareꢀinterruptꢀonꢀinfraredꢀtrigger
Sensorꢀisꢀdisabled
Power Down Mode
1.1 µA
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
4
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Part Number Specifications
Sensor Characteristics
Time Constant
(ms)
at 10 – 20 Hz Peak
Filter Aperture
(mm)
Element Size
(mm2)
Package
Field of View
5.2 x 4.2
1 x 1
TO39
~10
~100°
Electrical Characteristics
Supply
Operating
Temperature Temperature
Storage
Supply
Current
Voltage
(μA)
Digital
I/O
ΔΣ ADC
at 1 ksp
Sensor
Read-out
Configurable
Range
(°C)
Range
(°C)
(V)
Typical
Gain
I2Cꢀ(FM+ꢀ
compatible)
Digitalꢀfiltering
Sampling rate
Power modes
1.75 to 3.60
1 to 23
15ꢀ–ꢀ23ꢀbit
−40ꢀtoꢀ+85
−40ꢀtoꢀ+110
Current mode
Part Number (Sensor)
Part Number
Cut On Wavelength
Cut Off Wavelength
(μm) Typical
Weight
Filter Name
(μm) Typical
(gr)
0.95
0.95
0.95
0.95
USEQFCEA391100
USEQFCEA448100
USEQFCEA455100
USEQFCEA500100
3.91ꢀμmꢀbandpass
4.48ꢀμmꢀbandpass
4.55ꢀμmꢀbandpass
5.00ꢀμmꢀcutꢀon
3.865
3.955
4.790
4.760
–
4.170
4.340
5.000
Filters block up to 8 μm.
Evaluation Kits
• Quick prototype development
• Easy way to evaluate
•ꢀꢀꢀEasyꢀtoꢀinstallꢀsoftware
• Digital output
TheꢀdigitalꢀTOꢀInfraredꢀFlameꢀSensingꢀkitꢀisꢀtoꢀenableꢀtheꢀusersꢀtoꢀcarryꢀoutꢀaꢀsimpleꢀandꢀeffectiveꢀevaluationꢀofꢀtheꢀKEMETꢀ
QFCEꢀTO-39ꢀpackagedꢀflameꢀsensors,ꢀexperimentꢀwithꢀtheꢀsampleꢀflameꢀdetectionꢀratioꢀbasedꢀalgorithm,ꢀandꢀtoꢀcaptureꢀ
measuredꢀdataꢀtoꢀaꢀPC.ꢀTheꢀkitꢀisꢀbasedꢀonꢀtheꢀSTꢀmicroelectronicsꢀSTM32F303K8ꢀmicrocontrollerꢀwithꢀaꢀhighꢀprecisionꢀA-Dꢀ
converterꢀandꢀprogrammableꢀgainꢀamplifier.
Part Number
Use
Includes
Weight
Flame Detection Demonstrator Kit
SensorꢀUSEQFCEA500100ꢀ5.00ꢀμmꢀLongꢀPassꢀfilter
SensorꢀUSEQFCEA391100ꢀ3.91ꢀμmꢀ/ꢀ90ꢀnmꢀfilter
SensorꢀUSEQFCEA448100ꢀ4.48ꢀμmꢀ/ꢀ620ꢀnmꢀfilter
USBꢀcommunicationsꢀcable
Digital TO
Flame Sensing
Evaluation Kit
USEQFCK9000000
360 gr
USBꢀstickꢀwithꢀevaluationꢀsoftware
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
5
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
Packaging
Part Number
Packaging Type
Pieces per Tube
USEQFCE*******
Tube
50
Part Number
Packaging Type
Pieces per Box
USEQFCK9000000
CardboardꢀBox
1
Handling Precautions
PyroelectricꢀInfraredꢀSensorsꢀshouldꢀbeꢀkeptꢀawayꢀfromꢀindirectꢀandꢀdirectꢀsunlight,ꢀtheꢀheadlightsꢀofꢀcars,ꢀwind,ꢀandꢀ
exposureꢀtoꢀstrongꢀvibrationꢀandꢀstrongꢀshock.
Doꢀnotꢀuseꢀinꢀwater,ꢀalcoholꢀETA,ꢀcorrosiveꢀgasꢀorꢀunderꢀseaꢀbreeze.
Doꢀnotꢀbeꢀexposeꢀtoꢀcorrosiveꢀsubstances.
Do not drop or apply any mechanical stress.
TheꢀperformanceꢀofꢀthisꢀdeviceꢀcanꢀbeꢀaffectedꢀbyꢀESD.ꢀPrecautionsꢀshouldꢀbeꢀusedꢀwhenꢀhandlingꢀandꢀinstallingꢀtheꢀ
sensor.ꢀPrecisionꢀdevicesꢀsuchꢀasꢀthisꢀsensorꢀcanꢀbeꢀdamagedꢀorꢀcausedꢀnotꢀtoꢀmeetꢀpublishedꢀspecificationꢀdueꢀtoꢀESD.ꢀ
PleaseꢀnoteꢀthatꢀthereꢀisꢀlimitedꢀESDꢀprotectionꢀbuilt-inꢀasꢀtheꢀdeviceꢀisꢀoptimisedꢀforꢀlowꢀpowerꢀconsumptionꢀandꢀlowꢀnoiseꢀ
operation.ꢀHumanꢀBodyꢀModelꢀ(HBM),ꢀperꢀJS-001:ꢀ2,000ꢀV.
PyroelectricꢀInfraredꢀSensorsꢀshouldꢀbeꢀstoredꢀinꢀnormalꢀworkingꢀenvironments.
Solderabilityꢀwillꢀbeꢀdegradedꢀbyꢀexposureꢀtoꢀhighꢀtemperatures,ꢀhighꢀhumidity,ꢀcorrosiveꢀatmospheres,ꢀandꢀlong-termꢀ
storage.
KEMETꢀrecommendsꢀthatꢀambientꢀstorageꢀconditionsꢀareꢀ<ꢀ30°Cꢀandꢀ<ꢀ60%ꢀrelativeꢀhumidityꢀandꢀthatꢀmaximumꢀstorageꢀ
temperatureꢀdoesꢀnotꢀexceedꢀ110°C.ꢀAtmospheresꢀshouldꢀbeꢀfreeꢀofꢀchlorineꢀandꢀsulfur-bearingꢀcompounds.
Temperatureꢀfluctuationsꢀshouldꢀbeꢀminimizedꢀtoꢀavoidꢀcondensationꢀonꢀtheꢀparts.
Forꢀoptimizedꢀsolderabilityꢀsensorsꢀstockꢀshouldꢀbeꢀusedꢀpromptly,ꢀpreferablyꢀwithinꢀ24ꢀmonthsꢀofꢀreceipt.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
6
Flame Sensors – QFCE Pyroelectric Infrared Flame Sensors, I2C-TO
KEMET Electronics Corporation Sales Offices
Forꢀaꢀcompleteꢀlistꢀofꢀourꢀglobalꢀsalesꢀo ꢀꢀces,ꢀpleaseꢀvisitꢀwww.kemet.com/sales.
Disclaimer
Allꢀproductꢀspeci ꢀcations,ꢀstatements,ꢀinformationꢀandꢀdataꢀ(collectively,ꢀtheꢀ“Information”)ꢀinꢀthisꢀdatasheetꢀareꢀsubjectꢀtoꢀchange.ꢀTheꢀcustomerꢀisꢀresponsibleꢀforꢀ
checkingꢀandꢀverifyingꢀtheꢀextentꢀtoꢀwhichꢀtheꢀInformationꢀcontainedꢀinꢀthisꢀpublicationꢀisꢀapplicableꢀtoꢀanꢀorderꢀatꢀtheꢀtimeꢀtheꢀorderꢀisꢀplaced.ꢀAllꢀInformationꢀgivenꢀ
hereinꢀisꢀbelievedꢀtoꢀbeꢀaccurateꢀandꢀreliable,ꢀbutꢀitꢀisꢀpresentedꢀwithoutꢀguarantee,ꢀwarranty,ꢀorꢀresponsibilityꢀofꢀanyꢀkind,ꢀexpressedꢀorꢀimplied.
StatementsꢀofꢀsuitabilityꢀforꢀcertainꢀapplicationsꢀareꢀbasedꢀonꢀKEMETꢀElectronicsꢀCorporation’sꢀ(“KEMET”)ꢀknowledgeꢀofꢀtypicalꢀoperatingꢀconditionsꢀforꢀsuchꢀ
applications,ꢀbutꢀareꢀnotꢀintendedꢀtoꢀconstituteꢀ–ꢀandꢀKEMETꢀspeci ꢀcallyꢀdisclaimsꢀ–ꢀanyꢀwarrantyꢀconcerningꢀsuitabilityꢀforꢀaꢀspeci ꢀcꢀcustomerꢀapplicationꢀorꢀuse.ꢀ
TheꢀInformationꢀisꢀintendedꢀforꢀuseꢀonlyꢀbyꢀcustomersꢀwhoꢀhaveꢀtheꢀrequisiteꢀexperienceꢀandꢀcapabilityꢀtoꢀdetermineꢀtheꢀcorrectꢀproductsꢀforꢀtheirꢀapplication.ꢀAnyꢀ
technicalꢀadviceꢀinferredꢀfromꢀthisꢀInformationꢀorꢀotherwiseꢀprovidedꢀbyꢀKEMETꢀwithꢀreferenceꢀtoꢀtheꢀuseꢀofꢀKEMET’sꢀproductsꢀisꢀgivenꢀgratis,ꢀandꢀKEMETꢀassumesꢀnoꢀ
obligationꢀorꢀliabilityꢀforꢀtheꢀadviceꢀgivenꢀorꢀresultsꢀobtained.
AlthoughꢀKEMETꢀdesignsꢀandꢀmanufacturesꢀitsꢀproductsꢀtoꢀtheꢀmostꢀstringentꢀqualityꢀandꢀsafetyꢀstandards,ꢀgivenꢀtheꢀcurrentꢀstateꢀofꢀtheꢀart,ꢀisolatedꢀcomponentꢀ
failuresꢀmayꢀstillꢀoccur.ꢀAccordingly,ꢀcustomerꢀapplicationsꢀwhichꢀrequireꢀaꢀhighꢀdegreeꢀofꢀreliabilityꢀorꢀsafetyꢀshouldꢀemployꢀsuitableꢀdesignsꢀorꢀotherꢀsafeguardsꢀ
(suchꢀasꢀinstallationꢀofꢀprotectiveꢀcircuitryꢀorꢀredundancies)ꢀinꢀorderꢀtoꢀensureꢀthatꢀtheꢀfailureꢀofꢀanꢀelectricalꢀcomponentꢀdoesꢀnotꢀresultꢀinꢀaꢀriskꢀofꢀpersonalꢀinjuryꢀorꢀ
property damage.
Althoughꢀallꢀproduct–relatedꢀwarnings,ꢀcautionsꢀandꢀnotesꢀmustꢀbeꢀobserved,ꢀtheꢀcustomerꢀshouldꢀnotꢀassumeꢀthatꢀallꢀsafetyꢀmeasuresꢀareꢀindictedꢀorꢀthatꢀotherꢀ
measuresꢀmayꢀnotꢀbeꢀrequired.
WhenꢀprovidingꢀKEMETꢀproductsꢀandꢀtechnologiesꢀcontainedꢀhereinꢀtoꢀotherꢀcountries,ꢀꢀtheꢀcustomerꢀmustꢀabideꢀbyꢀtheꢀproceduresꢀandꢀprovisionsꢀstipulatedꢀinꢀallꢀ
applicableꢀexportꢀlawsꢀandꢀregulations,ꢀincludingꢀwithoutꢀlimitationꢀtheꢀInternationalꢀTra ꢀꢀcꢀinꢀArmsꢀRegulationsꢀ(ITAR),ꢀtheꢀUSꢀExportꢀAdministrationꢀRegulationsꢀ
(EAR)ꢀandꢀtheꢀJapanꢀForeignꢀExchangeꢀandꢀForeignꢀTradeꢀAct.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0221_QFCE • 7/8/2021
7