USEQFSK1000000 [KEMET]
QFS Pyroelectric Infrared Flame Sensors, I2C-SMD;型号: | USEQFSK1000000 |
厂家: | KEMET CORPORATION |
描述: | QFS Pyroelectric Infrared Flame Sensors, I2C-SMD |
文件: | 总11页 (文件大小:646K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Flame Sensors
QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Overview
Applications
KEMET’sꢀQFSꢀpyroelectricꢀflameꢀsensorsꢀcombineꢀhighꢀ
sensitivity with fast response times and high dynamic range
to ensure rapid and accurate detection of small and large
flames,ꢀnearbyꢀorꢀoverꢀlargerꢀdistances.
• Smart home
• Smart building
• Industrial IoT
• Transportation
These high quality sensors, in their small SMD package,
integrate a digital, current mode read-out offering high
responsivityꢀoverꢀtheꢀfullꢀfrequencyꢀrangeꢀofꢀflameꢀflickerꢀ
from 3 – 30 Hz. Industry standard I2C communication
enables plug-and-play connectivity to microcontrollers and
allows easy tuning and calibration. Programmable gain
andꢀfilteringꢀofferꢀmaximumꢀflexibilityꢀinꢀsystemꢀdesign,ꢀ
andꢀvariousꢀopticalꢀfilterꢀoptionsꢀareꢀalsoꢀavailable.ꢀTheseꢀ
sensors can be connected toegther in linear series to allow
synchronized sampling across devices.
Their long and maintenance-free operational lifetime and
various low power modes makes it ideal for any smart or
IoT type of applications.
Benefits
• High sensitivity with fast response time
• High dynamic range
• Small SMD package
• I2C communication compatible
• Digital and analog output
•ꢀ Programmableꢀgainꢀandꢀfilltering
•ꢀ Variousꢀopticalꢀfilterꢀoptions
•ꢀ Integratedꢀconfigurableꢀamplifier,ꢀfilter,ꢀandꢀADC
• Low power comsumption
One world. One KEMET
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
1
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Ordering Information
USE
QFS
E
A
22L1
8
0
Product
Family
Series
Sensor Type
Mounting Type
Specification
Packaging
Version
0
Sensors
QFS =
SMD
Flame
Sensors
E = Serial Output
M = Serial Module
K = Evaluation Kit
A = Sensor Only
1 = Module Type 1
or Kit Type 1
0000ꢀ=ꢀFixed
0 = Bulk
8 = 7" Tape & Reel
22L1 = 2.2 µm long pass
50L1 = 5.00 µm long pass (human motion rejection)
3911 = 3.91 µm (rejection channel)
4641ꢀ=ꢀ4.64ꢀµmꢀ(flameꢀchannelꢀwithꢀwideꢀFoV)
4481ꢀ=ꢀ4.48ꢀµmꢀ(flameꢀchannelꢀwithꢀmainꢀdetector)
Environmental Compliance
All KEMET Flame Sensors are RoHS and REACH Compliant.
Article 33(1) of the REACH Regulation states that manufacturers and importers of articles (products) are required to notify
their customers of the presence of any Substances of Very High Concern (SVHC) in their products exceeding 0.1% by weight
and provide instructions on safe use of the product.
KEMET Corporation reports regarding the Article 33(1) of REACH Regulation as follows:
1. Applicable Product: Flame Sensors (QFC & QFS series)
2. Report for the content of REACH SVHC list:
The product(s) above contains a substance by more than 0.1wt% per product weight that was published in the 8th update of
the REACH SVHC substances (December 19, 2012).
3. Regarding the safety of the flame sensors (Piezoceramic products):
The Piezoceramic that is used in this product becomes ceramic by sintering powder containing PZT as the main ingredient. It
is chemically stable, with minimum risks toward the human body or environment within the intended use of the product. Please
note that risks could occur in the case of inhalation or accidental oral uptake of powder ceramics.
4. Technical product information on the flame sensors (Piezoceramic products):
The manufacturing technique of the “piezoceramic products” whose main ingredient is Lead Titanium Zirconium Oxide (PZT)
has been established, and there is no alternative material that can exhibit superior performance than PZT at this moment.
Please note that the piezoceramic is listed as an exempt on RoHS (2011/65/EU) AnnexIII (7c.1).
5. The responsibility of piezoceramic manufacturers:
Piezoceramic manufacturers report information regarding PZT containment in their products to the customers to obey the
article 33 of the REACH regulation
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
2
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Dimensions – Millimeters
Sensor
ꢁꢂꢈꢅꢅ
ꢇꢂꢈꢅꢅ
2ꢉ
2ꢊ
2ꢇ
ꢁ
ꢁꢄ
ꢆ
ꢁꢉ
ꢁꢅ
ꢅꢂꢄꢅꢅ
ꢀꢁꢂꢃꢄꢅ or ꢀꢅꢂꢆꢅ
ꢇꢂꢅꢄꢅ
ꢅꢂꢄꢄꢅ
ꢁꢂꢇꢈꢅ
ꢁꢂꢄꢄ Maꢋimꢌm
Pin Configuration of Sensor
Pin ꢎ
Indication
ꢐSꢑꢒꢒly - ꢎ
CꢉP - ꢃ
ꢁꢂD - ꢊ
ꢁꢂD - ꢅ
2ꢃ - CS
2ꢎ - Cꢇꢏ
ꢎꢀ - ꢁꢂD
ꢎꢅ - ꢁꢂD
2ꢀ - ꢁꢂD
ꢃꢄ - ꢁꢂD
TꢀANSPAꢀENT TꢁP ꢂꢃEꢄ
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
3
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Dimensions – Millimeters cont.
Module
ꢀꢄꢂꢄꢄꢄ
ꢃꢂꢆ
ꢀꢅꢂꢄꢄꢄ
ꢁꢂꢅ
ꢀꢅ
ꢀꢁꢂꢃꢄꢄ
Field of View
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
4
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Performance Characteristics
Signal Filtering & Power Modes
Fixed
Analog
Low Pass Pass Filter
Filter (Hz)
Fixed
Digital Low
Maximum
ADC
Sampling Rate
(sps)
Power Mode
(base sample rate)
High Pass Filter – Analog
(Hz)
Digital Low Pass
Filter (Hz)
(Hz)
250
42
Normal Power Mode
Low Power Mode
Off
Off
1.0
2.0
4.0
8.0
600
180.0 90.0 45.0 22.5
30.00 15.00 7.50 3.75
1,000
0.17 0.33 0.66 1.30
100
166
Typical Current
Consumption
Item
Mode
Description
(1.8 V, room temperature)
Normal Power Mode
Low Power Mode
Normalꢀpowerꢀconsumption,ꢀ1ꢀkHzꢀmaximumꢀsampleꢀrate
Lowꢀpowerꢀconsumption,ꢀ166ꢀHzꢀmaximumꢀsampleꢀrate
Sensor signal readout over I2C
22 µA
3.5 µA
22 µA
Power consumption
Normal Operation Mode
21 µA (Normal Power Mode)
3.5 µA (Low Power Mode)
Operational state
Sleep Mode
Hardware interrupt on infrared trigger
Sensor is disabled
Power Down Mode
1.1 µA
Infrared Frequency Characteristics
Typical Frequency Response in
Normal Power Mode
Typical Frequency Response in
Low Power Mode
Typical Frequency Response at
Different Gain Settings
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
5
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Performance Characteristics cont.
Filter Transmission Profiles
Typical 2.2 µm LP Filter Transmission
Typical 5.0 µm LP Filter Transmission
Part Number Specifications
Sensor Characteristics
D*1
(cm√Hz/W)
Typical
NEP1
(W/√Hz)
Typical
Time Constant
(ms) at 10-20
Hz peak
Filter Aperture Element Size
SMD Package
(mm)
Field of View
(mm)
(mm2)
φꢀ1.65
0.64ꢀxꢀ0.64
5.65ꢀxꢀ3.70ꢀxꢀ1.55
2.5ꢀxꢀ108.0
2.7ꢀxꢀ10.0-10.0
~10
~90°
1 10 Hz, 500 K, room temperature, without window and optics.
Electrical Characteristics
Supply
Voltage
(V)
Supply
Current
(μA) Typical
Operating
Temperature Temperature
Range (°C)
Storage
ΔΣ ADC
at 1 ksp
Sensor
Read-out
Digital I/O
Configurable
Range (°C)
Gain
I2C
Digitalꢀfilterin
Sampling rate
Power modes
1.75 to 3.60
1 to 23
15 bit
−40ꢀtoꢀ+85
−40ꢀtoꢀ+110
Current mode
(FM+ compatible)
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
6
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Part Number Specifications cont.
Part Number (Sensor)
Part Number
USEQFSEA22L180
USEQFSEA50L180
USEQFSEA391180
USEQFSEA464180
USEQFSEA448180
Filter(μm)
2.20
Filter BW (nm)
Comment
Weight (gr)
0.07
Long pass
Long pass
90
5.00
Human motion rejection
Rejection channel
0.07
3.91
0.07
4.64
180
Flame channel (wide FoV)
0.07
Flame channel (main
detector)
4.48
620
0.07
Part Number (Module)
Part Number
Comment
Weight (gr)
5.40
USEQFSM122L100
USEQFSM150L100
USEQFSM1391100
USEQFSM1464100
USEQFSM1448100
Includes sensor: USEQFSEA22L180
Includes sensor: USEQFSEA50L180
Includes sensor: USEQFSEA391180
Includes sensor: USEQFSEA464180
Includes sensor: USEQFSEA448180
5.40
5.40
5.40
5.40
Part Number (Evaluation Kit)
Part Number
Comment
Weight (gr)
Includes 4 sensors: USEQFSEA50L180,
USEQFSEA391180, USEQFSEA464180 and
USEQFSEA448180
USEQFSK1000000
USEQCSK0000000
350
Controlꢀboardꢀforꢀmodules,ꢀmaximumꢀ4ꢀmodulesꢀ
250
can be connected on one control board
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
7
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Landing Pattern
Recommended PCB Landing Pattern
Part Schematic
Block Diagram
CS
Diꢁital Filter
Iꢏꢔ
SDꢀ
SCꢒ
M
C
ꢑ
ꢈꢛꢜ
∆Σ
ꢀDC
FIFꢘ
ꢀnaloꢁ
Front-ꢂnd
ꢔiminꢁ Ctrl
Interrꢅꢙt Ctrl
ꢚaꢗe-ꢅꢙ
Cꢒꢓ
SꢐꢏC
ꢃeferenceꢄꢃeꢁꢅlator
ꢆCC ꢇꢈꢉꢊ - ꢋꢉꢌ ꢆꢍ
Clocꢗ ꢎenerator
ꢆDD
ꢎꢏD
ꢕꢈꢖꢖnF
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
8
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Soldering Process
Recommended Reflow Soldering Profile
Profile Feature
Pb-Free Assembly
ꢀP
ꢀꢃ
tP
ꢀC −ꢁꢉC
Maꢂimꢄm ꢅamꢆ-ꢄꢆ ꢅate ꢇ ꢈꢉCꢊsecond
Maꢂimꢄm ꢅamꢆ-doꢋn ꢅate ꢇ ꢌꢉCꢊsecond
Preheat/Soak
Temperature Minimum (TSmin
)
150°C
200°C
tꢃ
TemperatureꢀMaximumꢀ(TSmax
Time (ts) from Tsmin to Tsmax
Ramp-Up Rate (TL to TP)
Liquidous Temperature (TL)
Time Above Liquidous (tL)
Peak Temperature (TP)
Time within 5°C of
)
ꢀsmaꢂ
ꢀsmin
60 – 120 seconds
3°C/secondꢀmaximum
217°C
ts
60 – 150 seconds
260°C
2ꢁ
2ꢁꢉC to Peaꢍ
Tꢀꢁꢂ
30ꢀsecondsꢀmaximum
MaximumꢀPeakꢀTemperatureꢀ(t)1
Ramp-Down Rate (TP to TL)
6°C/secondꢀmaximum
8ꢀminutesꢀmaximum
Time 25°C to Peak Temperature
1 Tolerance for peak profile temperature (TP) is defined as a supplier minimum and as a user maximum.
Packaging
Series
Packaging Type
Pieces per Reel
QFS
7" Tape & Reel
800
Taping Specification
Dimensions (mm)
A0 B0
P0
P
T
P2
W
K0
E
F
D0
Minimum
Typical
3.90
4.00
4.10
7.90
8.00
8.10
0.25
0.30
0.35
1.90
2.00
2.10
11.70
12.00
12.30
3.90
4.00
4.10
5.85
5.95
6.05
1.65
1.75
1.85
1.65
1.75
1.85
5.40
5.50
5.60
1.50
1.50
1.60
Maximum
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
9
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
Reel Specification
Dimensions (mm)
C1
C2
A
B
H
T
D
Tolerance
Nominal
±1.0
±0.2
13.5
±0.2
2.3
±0.2
10.4
±0.5
12.5
±0.2
1.6
±0.5
Ø54
Ø178
Handling Precautions
Pyroelectric Infrared Sensors should be kept away from indirect and direct sunlight, the headlights of cars, wind, and
exposureꢀtoꢀstrongꢀvibrationꢀandꢀstrongꢀshock.
Do not use in water, alcohol ETA, corrosive gas or under sea breeze.
Doꢀnotꢀbeꢀexposeꢀtoꢀcorrosiveꢀsubstances.
Do not drop or apply any mechanical stress.
The performance of this device can be affected by ESD. Precautions should be used when handling and installing the
sensor.ꢀPrecisionꢀdevicesꢀsuchꢀasꢀthisꢀsensorꢀcanꢀbeꢀdamagedꢀorꢀcausedꢀnotꢀtoꢀmeetꢀpublishedꢀspecificationꢀdueꢀtoꢀESD.ꢀ
Please note that there is limited ESD protection built-in as the device is optimised for low power consumption and low noise
operation. Human Body Model (HBM), per JS-001: 2,000 V.
The sensor is classed as Moisture Sensitivity Level 3 (MSL-3). The package should be handled according to IPC/JEDEC
J-STD-20.
Pyroelectric Infrared Sensors should be stored in normal working environments.
Solderabilityꢀwillꢀbeꢀdegradedꢀbyꢀexposureꢀtoꢀhighꢀtemperatures,ꢀhighꢀhumidity,ꢀcorrosiveꢀatmospheres,ꢀandꢀlong-termꢀ
storage.
KEMETꢀrecommendsꢀthatꢀambientꢀstorageꢀconditionsꢀareꢀ<ꢀ30°Cꢀandꢀ<ꢀ60%ꢀrelativeꢀhumidityꢀandꢀthatꢀmaximumꢀstorageꢀ
temperatureꢀdoesꢀnotꢀexceedꢀ110°C.ꢀAtmospheresꢀshouldꢀbeꢀfreeꢀofꢀchlorineꢀandꢀsulfur-bearingꢀcompounds.
Temperatureꢀfluctuationsꢀshouldꢀbeꢀminimizedꢀtoꢀavoidꢀcondensationꢀonꢀtheꢀparts.
For optimized solderability sensors stock should be used promptly, preferably within 24 months of receipt.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
10
Flame Sensors – QFS Pyroelectric Infrared Flame Sensors, I2C-SMD
KEMET Electronics Corporation Sales Offices
Forꢀaꢀcompleteꢀlistꢀofꢀourꢀglobalꢀsalesꢀoffiꢀꢀces,ꢀpleaseꢀvisitꢀwww.kemet.com/sales.
Disclaimer
Allꢀproductꢀspecifiꢀcations,ꢀstatements,ꢀinformationꢀandꢀdataꢀ(collectively,ꢀtheꢀ“Information”)ꢀinꢀthisꢀdatasheetꢀareꢀsubjectꢀtoꢀchange.ꢀTheꢀcustomerꢀisꢀresponsibleꢀforꢀ
checkingꢀandꢀverifyingꢀtheꢀextentꢀtoꢀwhichꢀtheꢀInformationꢀcontainedꢀinꢀthisꢀpublicationꢀisꢀapplicableꢀtoꢀanꢀorderꢀatꢀtheꢀtimeꢀtheꢀorderꢀisꢀplaced.ꢀAllꢀInformationꢀgivenꢀ
hereinꢀisꢀbelievedꢀtoꢀbeꢀaccurateꢀandꢀreliable,ꢀbutꢀitꢀisꢀpresentedꢀwithoutꢀguarantee,ꢀwarranty,ꢀorꢀresponsibilityꢀofꢀanyꢀkind,ꢀexpressedꢀorꢀimplied.
StatementsꢀofꢀsuitabilityꢀforꢀcertainꢀapplicationsꢀareꢀbasedꢀonꢀKEMETꢀElectronicsꢀCorporation’sꢀ(“KEMET”)ꢀknowledgeꢀofꢀtypicalꢀoperatingꢀconditionsꢀforꢀsuchꢀ
applications,ꢀbutꢀareꢀnotꢀintendedꢀtoꢀconstituteꢀ–ꢀandꢀKEMETꢀspecifiꢀcallyꢀdisclaimsꢀ–ꢀanyꢀwarrantyꢀconcerningꢀsuitabilityꢀforꢀaꢀspecifiꢀcꢀcustomerꢀapplicationꢀorꢀuse.ꢀ
TheꢀInformationꢀisꢀintendedꢀforꢀuseꢀonlyꢀbyꢀcustomersꢀwhoꢀhaveꢀtheꢀrequisiteꢀexperienceꢀandꢀcapabilityꢀtoꢀdetermineꢀtheꢀcorrectꢀproductsꢀforꢀtheirꢀapplication.ꢀAnyꢀ
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all
applicableꢀexportꢀlawsꢀandꢀregulations,ꢀincludingꢀwithoutꢀlimitationꢀtheꢀInternationalꢀTraffiꢀꢀcꢀinꢀArmsꢀRegulationsꢀ(ITAR),ꢀtheꢀUSꢀExportꢀAdministrationꢀRegulationsꢀ
(EAR)ꢀandꢀtheꢀJapanꢀForeignꢀExchangeꢀandꢀForeignꢀTradeꢀAct.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0211_QFS • 11/21/2019
11
相关型号:
©2020 ICPDF网 联系我们和版权申明