DSO6014L [KEYSIGHT]
Low-Profile Oscilloscopes;型号: | DSO6014L |
厂家: | Keysight Technologies |
描述: | Low-Profile Oscilloscopes |
文件: | 总17页 (文件大小:4303K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Keysight Technologies
InfiniiVision 6000L Series
Low-Profile Oscilloscopes
The most space efficient, and affordable
LXI C compliant oscilloscopes
Data Sheet
Introduction
Four channels in only 1U space
Industry-leading performance:
– 4-channel digital storage oscilloscope (DSO) models
– Low profile, high density 1U (4.45 cm, 1.75 inches) package
– LXI class C compliant
– 100 MHz, 500 MHz and 1 GHz analog bandwidth
– Up to 4 GSa/s sample rate
– Standard 8 Mpts MegaZoom III deep memory
– Full-scale connectivity – Standard USB, LAN, GPIB interface with XGA video output
– 8-bit vertical resolution (extensible to 12 bits)
– Built-in Web browser control
– IVI-COM driver
– 100% software compatible with 6000A Series portable oscilloscopes
– Optional segmented memory application
– Optional secure environment mode
The highest performance and lowest cost automated
test oscilloscope in its class.
03 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Low-profile, high-density
package saves rack space
The InfiniiVision 6000L Series
oscilloscopes provide up to 1-GHz
bandwidth in a space-saving
1U-high 19-inch wide package so
it saves your valuable rack space.
The oscilloscopes have side and
rear air vents (no top or bottom
air vents) so other instruments
can be mounted directly above or
below them. Rack mount brackets
and rack rails are standard with
every unit.
LXI class C compliant
LAN eXtensions for
Instrumentation (LXI) is the
architecture for test systems
that’s based on proven, widely
used standards such as Ethernet.
By specifying the interaction of
those standards, LXI enables
fast, efficient, cost-effective
creation and reconfiguration of
test systems. The InfiniiVision
6000L Series oscilloscopes are
fully LXI class C compliant.
The InfiniiVision 6000L Series
oscilloscopes follow specified
LAN protocols, and adhere to LXI
requirements such as a built-in
Web control server, IVI driver
software, and more.
Make the most of your rack space with an InfiniiVision 6000L Series oscilloscope.
Easy system integration
and configuration
To simplify system development,
the InfiniiVision 6000L Series
oscilloscopes come standard with
an IVI-COM (Interchangeable
Virtual Instruments) driver,
and they support easy-to-use
SCPI commands. The standard
Keysight Technologies, Inc. I/O
Library Suite makes it easy
Establish instrument connection faster with Keysight I/O Library Suite.
to configure and integrate
instruments into your system
– even if your system includes
instruments from other vendors.
04 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Built-in Web control
The built-in Web server provides
remote access and control of
the instrument via a standard
Java-enabled Web browser
on your computer. You can
communicate with the scope
over the scope’s built-in LAN
interface. Using the Web browser
you can set up measurements,
monitor waveforms, capture
screen images and operate
the scope remotely. Through
the remote front panel you
have access to the built-in help
system that is available in eleven
languages. Simply right click
on the soft keys to see help for
Remotely display and control your InfiniiVision 6000L oscilloscope from any
that function. You can also send
SCPI commands over the LAN
to control your scope. Wherever
you are, your InfiniiVision 6000L
Series scope is as close as the
nearest Web browser.
Java-enabled web browser over the oscilloscope’s built-in LAN interface.
Up to 12 bits of resolution
High resolution mode offers up
to 12 bits of resolution in real-
time mode, which reduces noise
and increases vertical resolution.
When operating at slow time
base ranges, the InfiniiVision
6000L Series oscilloscopes
serially filter sequential data
points and map the filtered
results to the display. In certain
situations, user-controlled
averaging can also be used to
obtain greater than 8-bits of
resolution.
Optional secure
environment mode
The optional secure environment
mode provides the highest
level of security by ensuring
that internal memory is clear
of all setup and trace settings
in compliance with National
Industrial Security Program
Operating Manual (NISPOM)
Chapter 8 requirements. You
can move the instrument out of
a secure area with confidence.
When this option is installed, it
will store setups and traces to
internal volatile memory only. To
permanently store data, you can
save it to an external memory
device via the oscilloscope’s
front-panel USB port.
Time base
Bits of resolution
< 100 nsec/div
500 nsec/div
2 µsec/div
8
9
10
11
12
10 µsec/div
≥ 50 µsec/div
05 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
resolution. This lets you quickly
The fast sample rate and deep
memory ensure that all high-
frequency signal components,
up to the full bandwidth of the
scope, are captured.
Powerful acquisition with
MegaZoom-III deep memory
zoom in on areas of interest.
In single-channel mode with
8 Mpts of memory, the DSO6104L
can capture a signal over a 2-msec
period with a sampling rate
of 4-GSa/s (0.25-nsec period).
8 Mpt of MegaZoom deep
memory comes standard so you
can capture long, non-repeating
signals, while maintaining high
sample rates and good timing
MegaZoomIIIdeepmemoryhelpsyoufinddetailsburiedincomplexsignals.Youcanviewfastwaveformupdatesofsignalsbymeansof
an external dislpay connected to the oscilloscope’s XGA out port.
06 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Mixed signal analysis option
If you work with both analog and
digital circuitry, the InfiniiVision
6000L Series oscilloscope can
help you see more signal activity
in your designs. You can upgrade
the 6000L Series oscilloscope to
a 4 scope +16 logic timing channel
mixed signal oscilloscope (MSO).
With the MSO you can trigger on
any combination of its scope and
logic channels.
Easy programming transition
One of the biggest challenges in
a new product’s life cycle is the
transition of its test system from
development to manufacturing.
With LXI, the transition can
be achieved much more easily
and cost effectively than with
cardcage-based systems.
The MSO option lets you see the complex interactions among your signals on up
to 20 channels at the same time.
Engineers can use the LXI class
C compliant InfiniiVision 6000A
Series portable oscilloscope
during the R&D phase, using
the display, keypad and knobs
to quickly access a wealth of
measurement capabilities.
When your product moves to
manufacturing, you can use a
system-optimized 6000L Series
LXI oscilloscope without
a display. Because the
InfiniiVision 6000A and 6000L
are 100% software compatible,
your manufacturing system can
use the software and test routines
developed in R&D without any
modification, while you save cost
and rack space by moving from a
standard bench-top oscilloscope
to a 1U high oscilloscope without
a display.
The InfiniiVision 6000A and 6000L Series oscilloscopes are 100% software compatible,
enabling smooth test system transition.
07 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Keysight InfiniiVision 6000L Series Oscilloscopes:
The most space efficient LXI C compliant oscilloscopes
Four channels in only 1U space
Standard rack
mount brackets
Status indicators
Side air vents
Waveform intensity control
(for external display)
AutoProbe Interface
Built-in USB port
XGA video out port
Standard LAN, USB and GPIB ports
Optional 16 logic timing channels (MSO)
Ext Trig in, Trig out and
10 MHz ref in/out
08 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Performance characteristics
Scope input
Channels
Ch 1, 2, 3 and 4 simultaneous acquisition
Bandwidth (–3 dB)*
DSO6014L: DC to 100 MHz
DSO6054L: DC to 500 MHz
DSO6104L: DC to 1 GHz
Maximum input
Full Scale range1
Input impedance
CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk
With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
5 Vrms with 50 Ω input
DSO6014L: 1 mV/div to 5 V/div (1 MΩ)
DSO6054L: 2 mV/div to 5 V/div (1 MΩ or 50 Ω)
DSO6104L: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
DSO6014L2: 1 MΩ 1% ꢀꢀ 11pF
DSO6054L/6104L: 1 MΩ 1% ꢀꢀ 14pF or 50 Ω 1.5%, selectable
Coupling
AC, DC
Offset range
5 V on ranges < 10 mV/div
25 V on ranges 10 mV/div to 200 mV/div
75 V on ranges ≥ 200 mV/div
Connector
BW limit
BNC
DSO6014L: 20MHz
DSO6054L/6104L: 25 MHz selectable
Noise peak-to-peak
DSO6014L: 3% full scale or 2 mV, whichever is greater
DSO6054L: 3% full scale or 3.6 mV, whichever is greater
DSO6104L: 3% full scale or 4.5 mV, whichever is greater
DC Vertical
*
Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.
1
2
1 mV/div is a magnification of 2 mV/div. 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity
setting and 32 mV for 2 mV/div sensitivity setting.
Four 50 Ω termination adapters are supplied with DSO6014L.
Logic channels (with MSO option)
Number of channels
Maximum input frequency
Sample rate
16 logic timing channels – labeled D15 - D0
250 MHz
2 GSa/sec one pod*, 1 GSa/sec each pod
Memory depth
1 pod /both pod
8 Mpts/4 Mpts
Standard memory
Vertical resolution
Threshold selections
Maximum input voltage
Glitch detection
1 bit
TTL, CMOS, ECL, user-definable (selectable by pod)
40 V peak CAT I
2 ns (min pulse width)
* A pod is a group of 8 digital channels. either 0-8 or 9-16
09 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Performance characteristics (continued)
Analog to digital conversion
Vertical resolution
8 bits
Sample rate
DSO6014L: 2 GSa/sec
DSO6054L/6104L: 4 GSa/sec half channel, 2 GSa/sec each channel
Equivalent-time sample rate: 400 GSa/s (when realtime mode is turned off)
Memory depth
Standard
2 channels/4 channels
8 Mpts/4 Mpts
Time range
5 nsec/div to 50 sec/div (DSO6014L)
1 nsec/div to 50 sec/div (DSO6054L)
500 psec/div to 50 sec/div (DSO6104L)
Acquisition
Acquisition mode
Normal, Peak Detect, Averaging, High Resolution
Peak detection
DSO6014L: 1 nsec peak detect
DSO6054L/6104L: 250 psec peak detect
Averaging
Selectable from 2,4,8,16,32,64… to 65536
High resolution mode
Time base
Bits of resolution
< 100 nsec/div
500 nsec/div
2 µsec/div
10 µsec/div
≥ 50 µsec/div
8
9
10
11
12
Filter
Sinx/x interpolation
Trigger system
Sources
DSO6xx4L: Ch 1, 2, 3, 4, line, ext and D0 - D15 for MSO enabled DSO
Modes
Auto, Normal, Single
Holdoff time range
Trigger jitter
Selections
~60 ns to 10 seconds
15 psec rms
Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I2C, SPI, Nth edge burst
Scope channel triggering
Range (internal)
6 div from center screen
Sensitivity*
< 10 mV/div: greater of 1 div or 5 mV
≥ 10mV/div: 0.6 div
Coupling
AC (~10 Hz), DC, noise reject, HF reject and LF reject (~ 50 kHz)
*
Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.
10 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Performance characteristics (continued)
Logic (D15 - D0) channel triggering (with MSO option)
Threshold range (user defined)
Threshold accuracy*
8.0 V in 10 mV increments
(100 mV + 3% of threshold setting)
TTL = 1.4 V, CMOS = 2.5 V, ECL = –1.3 V
Predefined thresholds
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.
External (EXT) triggering
Input resistance
1.015 kΩ 5% (DSO6014L)
2.14 kΩ 5% (DSO6054L/6104L)
Maximum input
Range
15 V
5 V
Sensitivity
DC to 100 MHz: 500 mV (DSO6014L)
DC to 500 MHz: 500 mV (DSO6054L/6104L)
AC (~ 3.5 Hz), DC, noise reject, HF reject and LF reject (~ 50 kHz)
Auto probe sense (DSO6014L)
Coupling
Probe ID
Auto probe sense and AutoProbe interface (DSO6054L/6104L)
Measurement features
Automatic measurements
Measurements are continuously updated. Cursors track last selected measurement
Voltage (scope channels only)
Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS,
standard deviation (AC RMS)
Time
Frequency, period, + width, – width and duty cycle on any channels
Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and
phase on scope channels only
Counter
Built-in 5-digit frequency counter on any scope channel. Counts up to the scope’s bandwidth
(1 GHz max). The counter resolution can be increased to 8 digits with an external 10 MHz
reference.
Threshold definition
Cursors
Variable by percent and absolute value; 10%, 50%, 90% default for time measurements
Manually or automatically placed readout of horizontal (X, ∆X, 1/∆X) and vertical (Y, ∆Y).
Tracking cursors provide an additional mode for cursor positioning beyond the current manual
method. When cursor tracking is enabled, changing a cursor's x-axis position results in the y-
axis cursor tracking the corresponding y-axis (voltage, current, etc.) value. Additionally logic or
scope channels can be displayed as binary or hex values
f (g(t))
Waveform math
g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}
f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square root
√g(t) } Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4
Note: Channels 3 and 4 only available on DSO6xx4L models
Measurement statistics
Statisticaldataforenabledmeasurementssuchasmean,min,max,standarddeviationandcount.
11 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Performance characteristics (continued)
FFT
Points
Fixed at 1000 points
Source of FFT
Window
Scope channels 1, 2, 3 or 4, 1+2, 1-2, 1x2
Rectangular, flattop, Hanning
–50 to –90 dB depending on averaging
Display in dBV, dBm at 50 Ω
0.05/(time per div)
Noise floor
Amplitude
Frequency resolution
Maximum frequency
50/(time per div)
Storage
Save/recall (non-volatile)
10 setups and traces can be saved and recalled internally. Secure environment mode (-SEC)
ensures setups and traces are stored to volatile memory.
Storage type and format
USB 1.1 drive on front (/drive0) and rear (/drive5) panels
Image formats: BMP (8 bit), BMP (24 bit) and PNG (24 bit)
Data formats: X and Y (time/voltage) values in CSV, ASCII XY and binary format
Trace/setup formats: Recalled
I/O
Standard ports
USB 2.0 high speed, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output
Max transfer rate
IEEE488.2 GPIB: 500 kbytes/sec
USB (USBTMC-USB488): 3.5 Mbytes/sec
100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Remote front panel
Built-in help
language support for English, German, French, Russian, Japanese, Traditional
Chinese, Simplified Chines, Korean, Spanish, Portuguese and Italian
Throughput of scope channels
Resolution of video output
Waveform controls
100,000 waveforms/sec in real-time mode to remote monitor
XGA
Waveform intensity of 256 levels, vectors on/off, infinite persistence on/off
General characteristics
Rack mounting
Suppliedwithallnecessaryhardware(excepttools)forinstallationintoastandardEIA19-inch
rack
Physical size
Weight
43.5 cm W x 27 cm D x 4.2 cm H (without brackets)
Net: 2.45 kg (5.4 lbs.)
Shipping: 6.2 kg (13.6 lbs.)
Probe comp output
Frequency ~1.2 kHz
Amplitude ~2.5 V
12 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Performance characteristics (continued)
General characteristics (continued)
Trigger out
When Triggers is selected
(delay ~17 ns)
0 to 5 V into high impedance
0 to 2.5 V into 50 Ω
When Source Frequency or
Source Frequency/8 is selected
0 to 580 mV into high impedance
0 to 290 mV into 50 Ω
Max frequency output
10 MHz ref in/out
350 MHz (in source frequency mode when terminated in 50 Ω)
125 MHz (in source frequency/8 mode when terminated in 50 Ω)
TTL out, 180 mV to 1 V amplitude within 0 to 2 V offset
Power requirements
Line voltage range
100-240 V, 50/60 Hz auto ranging
Line frequency
Power usage
50/60 Hz
80 W max
Environmental characteristics
Ambient temperature
Operating -10 ꢁC to +50 ꢁC; non-operating -40 ꢁC to +70 ꢁC
Humidity
Altitude
Vibration
Operating 95% RH at 40 ꢁC for 24 hours; Non-operating 90% RH at 65 ꢁC for 24 hours
Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft)
Keysight class GP and MIL-PRF-28800F; Class 3 random
Shock
axis
Keysight class GP and MIL-PRF-28800F; (operating 30 g, 1/2 sine, 11-ms duration, 3 shocks/
along major axis. Total of 18 shocks)
Pollution degree
Indoor use
Normally only dry non-conductive pollution occurs.
Occasionally a temporary conductivity caused by condensation must be expected.
This instrument is rated for indoor use only
Other
Installation categories
CAT I
EMC
IEC 61326-1:1997, EN 61326-1:1997
Safety
IEC 61010-1:2001, EN 61010-1:2001
Canada: CSA-C22.2 No. 1010.1:1992
UL 61010-1:2003
Supplementary information
TheproductherewithcomplieswiththerequirementsoftheLowVoltageDirective73/23/EEC
and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.
13 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Ordering information
Model number
DSO6104L
Description
1 GHz 4-ch DSO
500 MHz 4-ch DSO
100 MHz 4-ch DSO
DSO6054L
DSO6014L
Accessories included:
Model number
DSO6104L/6054L
√
DSO6014L
√
User’s guide, Service guide,
Programmer’s guide
Power cord
√
√
√
√
10:1 divider passive probe per
scope channel
Keysight IO Libraries Suite 14.2
GPIB extender
√
√
√
√
√
√
√
50 Ω termination adapter
Crossover LAN cable
√
√
Rack mount hardware
Available options
Option number
Description
DSO6014L
DSO6054L/6104L
N2914A*
MSO upgrade kit
√
N2915A*
MSO upgrade kit
√
√
√
√
√
√
√
√
N5427A(-SEC)
N5423A(-LSS)
N5424A(-AMS)
N5454A(- SGM)
N5457A (- 232)
N5468A
Secure environment mode
√
√
√
√
√
√
√
I2C/SPI triggering and decode option
CAN/LIN triggering and decode option
Segmented memory application
RS-232/UART triggering and decode
I2S Triggering and decode option
Mask testing- limit
N5455A
*
Includes a 54620-68701 logic cable kit, a label and an upgrade key code to activate the MSO features
14 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Ordering information (continued)
Warranty and calibration options
Contact local sales office for prices of extended options.
Passive probes
Product number
10070C
Description
1:1 passive probe with ID
10074C
10:1 150MHz passive probe with ID (shipped standard with DSO6014L model)
10:1 500 MHz passive probe with ID (shipped standard with DSO6054L/6104L models)
10073C
Current probes
Product number
1146A
Description
100-kHz current probe, ac/dc
1147B
50-MHz/15A current probe, ac/dc with AutoProbe interface
(power supply not required)
N2780A
N2781A
N2782A
N2783A
N2779A
2MHz/500A current probe, AC/DC
10MHz/150A current probe, AC/DC
50MHz/30A current probe, AC/DC
100MHz/30A current probe, AC/DC
Power supply for N278xA current probes
High-voltage probes
Product number
10076A
Description
100:1, 4 kV, 250-MHz probe with ID
N2771A
1000:1, 15 kV, 50-MHz high-voltage probe
Logic probes
Product number
10085-68701
54620-68701
Description
16:16 logic cable and terminator
16:2 x 8 logic input probe assembly
15 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Ordering information (continued)
Active single-ended probes
Product number
1144A
Description
800-MHz active probe
1145A
2-channel 750-MHz active probe
Power supply for 1144A and 1145A
1.5-GHz active probe with AutoProbe interface (power supply not required)
1142A
1156A
Active differential probes
Product number
N2791A
Description
25 MHz differential probe
1130A
1.5 GHz InfiniiMax differential probe amplifier with AutoProbe interface
(Order one or more InfiniiMax probe heads or connectivity kits per amplifier.)
16 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
Related Literature
Publication Title
Publication Type
Data sheet
Publication Number
5989-2000EN/EUS
5968-8153EN/EUS
Keysight 6000 Series Oscilloscopes
Keysight 6000 Series and 54600 Series
Oscilloscope Probes and Accessories
Data sheet
Option SEC N5427A Secure Environment
Mode Option
Data sheet
5968-5558EN
Next-Generation Test Systems
Application note
Application note
5989-2802EN
LXI: Going Beyond GPIB, PXI and VXI
5989-4371EN
Optimizing Test Systems for Highest Throughput,
Lowest Cost and Ease of Integration with
LXI Instruments
Application note59849-86EN
Open the Door to Simpler System Creation
Brochure
5989-2042EN
5989-7833EN
N5454A Segmented Memory Acquisition for
Keysight InfiniiVision Series Oscilloscopes
Data sheet
Keysight Triggering and Hardware-based Decode
(Option SND) for Keysight InfiniiVision
Oscilloscoopes
D a t a s h e e t 5990-4198EN
Keysight Technologies Oscilloscopes
Multiple form factors from ꢂꢃꢄMHz to >ꢅꢃꢄGHz ꢀ Industry leading specs ꢀ Powerful applications
17 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet
For more information on Keysight
Evolving Since 1939
Our unique combination of hardware, software, services, and people can help you
reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight.
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Other AP Countries
www.keysight.com/find/emt_product_registration
Register your products to get up-to-date product information and
find warranty information.
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Keysight Services
www.keysight.com/find/service
Keysight Services can help from acquisition to renewal across your
instrument’s lifecycle. Our comprehensive service offerings—one-
stop calibration, repair, asset management, technology refresh,
consulting, training and more—helps you improve product quality
and lower costs.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure
your instruments are operating to specification, so you can rely on
accurate measurements.
Spain
Sweden
Switzerland
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
Keysight Channel Partners
www.keysight.com/find/channelpartners
United Kingdom
Get the best of both worlds: Keysight’s measurement expertise and
product breadth, combined with channel partner convenience.
For other unlisted countries:
www.keysight.com/find/contactus
(BP-9-7-17)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2011 - 2017
Published in USA, December 1, 2017
5989-5470EN
www.keysight.com
相关型号:
©2020 ICPDF网 联系我们和版权申明