DSO6014L [KEYSIGHT]

Low-Profile Oscilloscopes;
DSO6014L
型号: DSO6014L
厂家: Keysight Technologies    Keysight Technologies
描述:

Low-Profile Oscilloscopes

文件: 总17页 (文件大小:4303K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Keysight Technologies  
InfiniiVision 6000L Series  
Low-Profile Oscilloscopes  
The most space efficient, and affordable  
LXI C compliant oscilloscopes  
Data Sheet  
Introduction  
Four channels in only 1U space  
Industry-leading performance:  
4-channel digital storage oscilloscope (DSO) models  
Low profile, high density 1U (4.45 cm, 1.75 inches) package  
LXI class C compliant  
100 MHz, 500 MHz and 1 GHz analog bandwidth  
Up to 4 GSa/s sample rate  
Standard 8 Mpts MegaZoom III deep memory  
Full-scale connectivity – Standard USB, LAN, GPIB interface with XGA video output  
8-bit vertical resolution (extensible to 12 bits)  
Built-in Web browser control  
IVI-COM driver  
100% software compatible with 6000A Series portable oscilloscopes  
Optional segmented memory application  
Optional secure environment mode  
The highest performance and lowest cost automated  
test oscilloscope in its class.  
03 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Low-profile, high-density  
package saves rack space  
The InfiniiVision 6000L Series  
oscilloscopes provide up to 1-GHz  
bandwidth in a space-saving  
1U-high 19-inch wide package so  
it saves your valuable rack space.  
The oscilloscopes have side and  
rear air vents (no top or bottom  
air vents) so other instruments  
can be mounted directly above or  
below them. Rack mount brackets  
and rack rails are standard with  
every unit.  
LXI class C compliant  
LAN eXtensions for  
Instrumentation (LXI) is the  
architecture for test systems  
that’s based on proven, widely  
used standards such as Ethernet.  
By specifying the interaction of  
those standards, LXI enables  
fast, efficient, cost-effective  
creation and reconfiguration of  
test systems. The InfiniiVision  
6000L Series oscilloscopes are  
fully LXI class C compliant.  
The InfiniiVision 6000L Series  
oscilloscopes follow specified  
LAN protocols, and adhere to LXI  
requirements such as a built-in  
Web control server, IVI driver  
software, and more.  
Make the most of your rack space with an InfiniiVision 6000L Series oscilloscope.  
Easy system integration  
and configuration  
To simplify system development,  
the InfiniiVision 6000L Series  
oscilloscopes come standard with  
an IVI-COM (Interchangeable  
Virtual Instruments) driver,  
and they support easy-to-use  
SCPI commands. The standard  
Keysight Technologies, Inc. I/O  
Library Suite makes it easy  
Establish instrument connection faster with Keysight I/O Library Suite.  
to configure and integrate  
instruments into your system  
– even if your system includes  
instruments from other vendors.  
04 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Built-in Web control  
The built-in Web server provides  
remote access and control of  
the instrument via a standard  
Java-enabled Web browser  
on your computer. You can  
communicate with the scope  
over the scope’s built-in LAN  
interface. Using the Web browser  
you can set up measurements,  
monitor waveforms, capture  
screen images and operate  
the scope remotely. Through  
the remote front panel you  
have access to the built-in help  
system that is available in eleven  
languages. Simply right click  
on the soft keys to see help for  
Remotely display and control your InfiniiVision 6000L oscilloscope from any  
that function. You can also send  
SCPI commands over the LAN  
to control your scope. Wherever  
you are, your InfiniiVision 6000L  
Series scope is as close as the  
nearest Web browser.  
Java-enabled web browser over the oscilloscope’s built-in LAN interface.  
Up to 12 bits of resolution  
High resolution mode offers up  
to 12 bits of resolution in real-  
time mode, which reduces noise  
and increases vertical resolution.  
When operating at slow time  
base ranges, the InfiniiVision  
6000L Series oscilloscopes  
serially filter sequential data  
points and map the filtered  
results to the display. In certain  
situations, user-controlled  
averaging can also be used to  
obtain greater than 8-bits of  
resolution.  
Optional secure  
environment mode  
The optional secure environment  
mode provides the highest  
level of security by ensuring  
that internal memory is clear  
of all setup and trace settings  
in compliance with National  
Industrial Security Program  
Operating Manual (NISPOM)  
Chapter 8 requirements. You  
can move the instrument out of  
a secure area with confidence.  
When this option is installed, it  
will store setups and traces to  
internal volatile memory only. To  
permanently store data, you can  
save it to an external memory  
device via the oscilloscope’s  
front-panel USB port.  
Time base  
Bits of resolution  
< 100 nsec/div  
500 nsec/div  
2 µsec/div  
8
9
10  
11  
12  
10 µsec/div  
≥ 50 µsec/div  
05 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
resolution. This lets you quickly  
The fast sample rate and deep  
memory ensure that all high-  
frequency signal components,  
up to the full bandwidth of the  
scope, are captured.  
Powerful acquisition with  
MegaZoom-III deep memory  
zoom in on areas of interest.  
In single-channel mode with  
8 Mpts of memory, the DSO6104L  
can capture a signal over a 2-msec  
period with a sampling rate  
of 4-GSa/s (0.25-nsec period).  
8 Mpt of MegaZoom deep  
memory comes standard so you  
can capture long, non-repeating  
signals, while maintaining high  
sample rates and good timing  
MegaZoomIIIdeepmemoryhelpsyoufinddetailsburiedincomplexsignals.Youcanviewfastwaveformupdatesofsignalsbymeansof  
an external dislpay connected to the oscilloscope’s XGA out port.  
06 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Mixed signal analysis option  
If you work with both analog and  
digital circuitry, the InfiniiVision  
6000L Series oscilloscope can  
help you see more signal activity  
in your designs. You can upgrade  
the 6000L Series oscilloscope to  
a 4 scope +16 logic timing channel  
mixed signal oscilloscope (MSO).  
With the MSO you can trigger on  
any combination of its scope and  
logic channels.  
Easy programming transition  
One of the biggest challenges in  
a new product’s life cycle is the  
transition of its test system from  
development to manufacturing.  
With LXI, the transition can  
be achieved much more easily  
and cost effectively than with  
cardcage-based systems.  
The MSO option lets you see the complex interactions among your signals on up  
to 20 channels at the same time.  
Engineers can use the LXI class  
C compliant InfiniiVision 6000A  
Series portable oscilloscope  
during the R&D phase, using  
the display, keypad and knobs  
to quickly access a wealth of  
measurement capabilities.  
When your product moves to  
manufacturing, you can use a  
system-optimized 6000L Series  
LXI oscilloscope without  
a display. Because the  
InfiniiVision 6000A and 6000L  
are 100% software compatible,  
your manufacturing system can  
use the software and test routines  
developed in R&D without any  
modification, while you save cost  
and rack space by moving from a  
standard bench-top oscilloscope  
to a 1U high oscilloscope without  
a display.  
The InfiniiVision 6000A and 6000L Series oscilloscopes are 100% software compatible,  
enabling smooth test system transition.  
07 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Keysight InfiniiVision 6000L Series Oscilloscopes:  
The most space efficient LXI C compliant oscilloscopes  
Four channels in only 1U space  
Standard rack  
mount brackets  
Status indicators  
Side air vents  
Waveform intensity control  
(for external display)  
AutoProbe Interface  
Built-in USB port  
XGA video out port  
Standard LAN, USB and GPIB ports  
Optional 16 logic timing channels (MSO)  
Ext Trig in, Trig out and  
10 MHz ref in/out  
08 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Performance characteristics  
Scope input  
Channels  
Ch 1, 2, 3 and 4 simultaneous acquisition  
Bandwidth (–3 dB)*  
DSO6014L: DC to 100 MHz  
DSO6054L: DC to 500 MHz  
DSO6104L: DC to 1 GHz  
Maximum input  
Full Scale range1  
Input impedance  
CAT I 300 Vrms, 400 Vpk, CAT II 100 Vrms, 400 Vpk  
With 10073C/10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk  
5 Vrms with 50 Ω input  
DSO6014L: 1 mV/div to 5 V/div (1 MΩ)  
DSO6054L: 2 mV/div to 5 V/div (1 MΩ or 50 Ω)  
DSO6104L: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)  
DSO6014L2: 1 MΩ 1% ꢀꢀ 11pF  
DSO6054L/6104L: 1 MΩ 1% ꢀꢀ 14pF or 50 Ω 1.5%, selectable  
Coupling  
AC, DC  
Offset range  
5 V on ranges < 10 mV/div  
25 V on ranges 10 mV/div to 200 mV/div  
75 V on ranges ≥ 200 mV/div  
Connector  
BW limit  
BNC  
DSO6014L: 20MHz  
DSO6054L/6104L: 25 MHz selectable  
Noise peak-to-peak  
DSO6014L: 3% full scale or 2 mV, whichever is greater  
DSO6054L: 3% full scale or 3.6 mV, whichever is greater  
DSO6104L: 3% full scale or 4.5 mV, whichever is greater  
DC Vertical  
*
Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.  
1
2
1 mV/div is a magnification of 2 mV/div. 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity  
setting and 32 mV for 2 mV/div sensitivity setting.  
Four 50 Ω termination adapters are supplied with DSO6014L.  
Logic channels (with MSO option)  
Number of channels  
Maximum input frequency  
Sample rate  
16 logic timing channels – labeled D15 - D0  
250 MHz  
2 GSa/sec one pod*, 1 GSa/sec each pod  
Memory depth  
1 pod /both pod  
8 Mpts/4 Mpts  
Standard memory  
Vertical resolution  
Threshold selections  
Maximum input voltage  
Glitch detection  
1 bit  
TTL, CMOS, ECL, user-definable (selectable by pod)  
40 V peak CAT I  
2 ns (min pulse width)  
* A pod is a group of 8 digital channels. either 0-8 or 9-16  
09 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Performance characteristics (continued)  
Analog to digital conversion  
Vertical resolution  
8 bits  
Sample rate  
DSO6014L: 2 GSa/sec  
DSO6054L/6104L: 4 GSa/sec half channel, 2 GSa/sec each channel  
Equivalent-time sample rate: 400 GSa/s (when realtime mode is turned off)  
Memory depth  
Standard  
2 channels/4 channels  
8 Mpts/4 Mpts  
Time range  
5 nsec/div to 50 sec/div (DSO6014L)  
1 nsec/div to 50 sec/div (DSO6054L)  
500 psec/div to 50 sec/div (DSO6104L)  
Acquisition  
Acquisition mode  
Normal, Peak Detect, Averaging, High Resolution  
Peak detection  
DSO6014L: 1 nsec peak detect  
DSO6054L/6104L: 250 psec peak detect  
Averaging  
Selectable from 2,4,8,16,32,64… to 65536  
High resolution mode  
Time base  
Bits of resolution  
< 100 nsec/div  
500 nsec/div  
2 µsec/div  
10 µsec/div  
≥ 50 µsec/div  
8
9
10  
11  
12  
Filter  
Sinx/x interpolation  
Trigger system  
Sources  
DSO6xx4L: Ch 1, 2, 3, 4, line, ext and D0 - D15 for MSO enabled DSO  
Modes  
Auto, Normal, Single  
Holdoff time range  
Trigger jitter  
Selections  
~60 ns to 10 seconds  
15 psec rms  
Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I2C, SPI, Nth edge burst  
Scope channel triggering  
Range (internal)  
6 div from center screen  
Sensitivity*  
< 10 mV/div: greater of 1 div or 5 mV  
≥ 10mV/div: 0.6 div  
Coupling  
AC (~10 Hz), DC, noise reject, HF reject and LF reject (~ 50 kHz)  
*
Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.  
10 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Performance characteristics (continued)  
Logic (D15 - D0) channel triggering (with MSO option)  
Threshold range (user defined)  
Threshold accuracy*  
8.0 V in 10 mV increments  
(100 mV + 3% of threshold setting)  
TTL = 1.4 V, CMOS = 2.5 V, ECL = –1.3 V  
Predefined thresholds  
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and 10 ꢁC from firmware calibration temperature.  
External (EXT) triggering  
Input resistance  
1.015 kΩ 5% (DSO6014L)  
2.14 kΩ 5% (DSO6054L/6104L)  
Maximum input  
Range  
15 V  
5 V  
Sensitivity  
DC to 100 MHz: 500 mV (DSO6014L)  
DC to 500 MHz: 500 mV (DSO6054L/6104L)  
AC (~ 3.5 Hz), DC, noise reject, HF reject and LF reject (~ 50 kHz)  
Auto probe sense (DSO6014L)  
Coupling  
Probe ID  
Auto probe sense and AutoProbe interface (DSO6054L/6104L)  
Measurement features  
Automatic measurements  
Measurements are continuously updated. Cursors track last selected measurement  
Voltage (scope channels only)  
Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS,  
standard deviation (AC RMS)  
Time  
Frequency, period, + width, – width and duty cycle on any channels  
Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and  
phase on scope channels only  
Counter  
Built-in 5-digit frequency counter on any scope channel. Counts up to the scope’s bandwidth  
(1 GHz max). The counter resolution can be increased to 8 digits with an external 10 MHz  
reference.  
Threshold definition  
Cursors  
Variable by percent and absolute value; 10%, 50%, 90% default for time measurements  
Manually or automatically placed readout of horizontal (X, ∆X, 1/∆X) and vertical (Y, Y).  
Tracking cursors provide an additional mode for cursor positioning beyond the current manual  
method. When cursor tracking is enabled, changing a cursor's x-axis position results in the y-  
axis cursor tracking the corresponding y-axis (voltage, current, etc.) value. Additionally logic or  
scope channels can be displayed as binary or hex values  
f (g(t))  
Waveform math  
g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}  
f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square root  
√g(t) } Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4  
Note: Channels 3 and 4 only available on DSO6xx4L models  
Measurement statistics  
Statisticaldataforenabledmeasurementssuchasmean,min,max,standarddeviationandcount.  
11 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Performance characteristics (continued)  
FFT  
Points  
Fixed at 1000 points  
Source of FFT  
Window  
Scope channels 1, 2, 3 or 4, 1+2, 1-2, 1x2  
Rectangular, flattop, Hanning  
–50 to –90 dB depending on averaging  
Display in dBV, dBm at 50 Ω  
0.05/(time per div)  
Noise floor  
Amplitude  
Frequency resolution  
Maximum frequency  
50/(time per div)  
Storage  
Save/recall (non-volatile)  
10 setups and traces can be saved and recalled internally. Secure environment mode (-SEC)  
ensures setups and traces are stored to volatile memory.  
Storage type and format  
USB 1.1 drive on front (/drive0) and rear (/drive5) panels  
Image formats: BMP (8 bit), BMP (24 bit) and PNG (24 bit)  
Data formats: X and Y (time/voltage) values in CSV, ASCII XY and binary format  
Trace/setup formats: Recalled  
I/O  
Standard ports  
USB 2.0 high speed, 10/100-BaseT LAN, IEEE488.2 GPIB, XGA video output  
Max transfer rate  
IEEE488.2 GPIB: 500 kbytes/sec  
USB (USBTMC-USB488): 3.5 Mbytes/sec  
100 Mbps LAN (TCP/IP): 1 Mbytes/sec  
Remote front panel  
Built-in help  
language support for English, German, French, Russian, Japanese, Traditional  
Chinese, Simplified Chines, Korean, Spanish, Portuguese and Italian  
Throughput of scope channels  
Resolution of video output  
Waveform controls  
100,000 waveforms/sec in real-time mode to remote monitor  
XGA  
Waveform intensity of 256 levels, vectors on/off, infinite persistence on/off  
General characteristics  
Rack mounting  
Suppliedwithallnecessaryhardware(excepttools)forinstallationintoastandardEIA19-inch  
rack  
Physical size  
Weight  
43.5 cm W x 27 cm D x 4.2 cm H (without brackets)  
Net: 2.45 kg (5.4 lbs.)  
Shipping: 6.2 kg (13.6 lbs.)  
Probe comp output  
Frequency ~1.2 kHz  
Amplitude ~2.5 V  
12 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Performance characteristics (continued)  
General characteristics (continued)  
Trigger out  
When Triggers is selected  
(delay ~17 ns)  
0 to 5 V into high impedance  
0 to 2.5 V into 50 Ω  
When Source Frequency or  
Source Frequency/8 is selected  
0 to 580 mV into high impedance  
0 to 290 mV into 50 Ω  
Max frequency output  
10 MHz ref in/out  
350 MHz (in source frequency mode when terminated in 50 Ω)  
125 MHz (in source frequency/8 mode when terminated in 50 Ω)  
TTL out, 180 mV to 1 V amplitude within 0 to 2 V offset  
Power requirements  
Line voltage range  
100-240 V, 50/60 Hz auto ranging  
Line frequency  
Power usage  
50/60 Hz  
80 W max  
Environmental characteristics  
Ambient temperature  
Operating -10 ꢁC to +50 ꢁC; non-operating -40 ꢁC to +70 ꢁC  
Humidity  
Altitude  
Vibration  
Operating 95% RH at 40 ꢁC for 24 hours; Non-operating 90% RH at 65 ꢁC for 24 hours  
Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft)  
Keysight class GP and MIL-PRF-28800F; Class 3 random  
Shock  
axis  
Keysight class GP and MIL-PRF-28800F; (operating 30 g, 1/2 sine, 11-ms duration, 3 shocks/  
along major axis. Total of 18 shocks)  
Pollution degree  
Indoor use  
Normally only dry non-conductive pollution occurs.  
Occasionally a temporary conductivity caused by condensation must be expected.  
This instrument is rated for indoor use only  
Other  
Installation categories  
CAT I  
EMC  
IEC 61326-1:1997, EN 61326-1:1997  
Safety  
IEC 61010-1:2001, EN 61010-1:2001  
Canada: CSA-C22.2 No. 1010.1:1992  
UL 61010-1:2003  
Supplementary information  
TheproductherewithcomplieswiththerequirementsoftheLowVoltageDirective73/23/EEC  
and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.  
13 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Ordering information  
Model number  
DSO6104L  
Description  
1 GHz 4-ch DSO  
500 MHz 4-ch DSO  
100 MHz 4-ch DSO  
DSO6054L  
DSO6014L  
Accessories included:  
Model number  
DSO6104L/6054L  
DSO6014L  
User’s guide, Service guide,  
Programmer’s guide  
Power cord  
10:1 divider passive probe per  
scope channel  
Keysight IO Libraries Suite 14.2  
GPIB extender  
50 Ω termination adapter  
Crossover LAN cable  
Rack mount hardware  
Available options  
Option number  
Description  
DSO6014L  
DSO6054L/6104L  
N2914A*  
MSO upgrade kit  
N2915A*  
MSO upgrade kit  
N5427A(-SEC)  
N5423A(-LSS)  
N5424A(-AMS)  
N5454A(- SGM)  
N5457A (- 232)  
N5468A  
Secure environment mode  
I2C/SPI triggering and decode option  
CAN/LIN triggering and decode option  
Segmented memory application  
RS-232/UART triggering and decode  
I2S Triggering and decode option  
Mask testing- limit  
N5455A  
*
Includes a 54620-68701 logic cable kit, a label and an upgrade key code to activate the MSO features  
14 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Ordering information (continued)  
Warranty and calibration options  
Contact local sales office for prices of extended options.  
Passive probes  
Product number  
10070C  
Description  
1:1 passive probe with ID  
10074C  
10:1 150MHz passive probe with ID (shipped standard with DSO6014L model)  
10:1 500 MHz passive probe with ID (shipped standard with DSO6054L/6104L models)  
10073C  
Current probes  
Product number  
1146A  
Description  
100-kHz current probe, ac/dc  
1147B  
50-MHz/15A current probe, ac/dc with AutoProbe interface  
(power supply not required)  
N2780A  
N2781A  
N2782A  
N2783A  
N2779A  
2MHz/500A current probe, AC/DC  
10MHz/150A current probe, AC/DC  
50MHz/30A current probe, AC/DC  
100MHz/30A current probe, AC/DC  
Power supply for N278xA current probes  
High-voltage probes  
Product number  
10076A  
Description  
100:1, 4 kV, 250-MHz probe with ID  
N2771A  
1000:1, 15 kV, 50-MHz high-voltage probe  
Logic probes  
Product number  
10085-68701  
54620-68701  
Description  
16:16 logic cable and terminator  
16:2 x 8 logic input probe assembly  
15 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Ordering information (continued)  
Active single-ended probes  
Product number  
1144A  
Description  
800-MHz active probe  
1145A  
2-channel 750-MHz active probe  
Power supply for 1144A and 1145A  
1.5-GHz active probe with AutoProbe interface (power supply not required)  
1142A  
1156A  
Active differential probes  
Product number  
N2791A  
Description  
25 MHz differential probe  
1130A  
1.5 GHz InfiniiMax differential probe amplifier with AutoProbe interface  
(Order one or more InfiniiMax probe heads or connectivity kits per amplifier.)  
16 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
Related Literature  
Publication Title  
Publication Type  
Data sheet  
Publication Number  
5989-2000EN/EUS  
5968-8153EN/EUS  
Keysight 6000 Series Oscilloscopes  
Keysight 6000 Series and 54600 Series  
Oscilloscope Probes and Accessories  
Data sheet  
Option SEC N5427A Secure Environment  
Mode Option  
Data sheet  
5968-5558EN  
Next-Generation Test Systems  
Application note  
Application note  
5989-2802EN  
LXI: Going Beyond GPIB, PXI and VXI  
5989-4371EN  
Optimizing Test Systems for Highest Throughput,  
Lowest Cost and Ease of Integration with  
LXI Instruments  
Application note59849-86EN  
Open the Door to Simpler System Creation  
Brochure  
5989-2042EN  
5989-7833EN  
N5454A Segmented Memory Acquisition for  
Keysight InfiniiVision Series Oscilloscopes  
Data sheet  
Keysight Triggering and Hardware-based Decode  
(Option SND) for Keysight InfiniiVision  
Oscilloscoopes  
D a t a s h e e t 5990-4198EN  
Keysight Technologies Oscilloscopes  
Multiple form factors from ꢂꢃꢄMHz to >ꢅꢃꢄGHz ꢀ Industry leading specs ꢀ Powerful applications  
17 | Keysight | InfiniiVision 6000L Series Low-Profile Oscilloscopes - Data Sheet  
For more information on Keysight  
Evolving Since 1939  
Our unique combination of hardware, software, services, and people can help you  
reach your next breakthrough. We are unlocking the future of technology.  
From Hewlett-Packard to Agilent to Keysight.  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
myKeysight  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
Other AP Countries  
www.keysight.com/find/emt_product_registration  
Register your products to get up-to-date product information and  
find warranty information.  
Europe & Middle East  
Austria  
Belgium  
Finland  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
Keysight Services  
www.keysight.com/find/service  
Keysight Services can help from acquisition to renewal across your  
instrument’s lifecycle. Our comprehensive service offerings—one-  
stop calibration, repair, asset management, technology refresh,  
consulting, training and more—helps you improve product quality  
and lower costs.  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure  
your instruments are operating to specification, so you can rely on  
accurate measurements.  
Spain  
Sweden  
Switzerland  
Opt. 2 (FR)  
Opt. 3 (IT)  
0800 0260637  
Keysight Channel Partners  
www.keysight.com/find/channelpartners  
United Kingdom  
Get the best of both worlds: Keysight’s measurement expertise and  
product breadth, combined with channel partner convenience.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-9-7-17)  
DEKRA Certified  
ISO9001 Quality Management System  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
This information is subject to change without notice.  
© Keysight Technologies, 2011 - 2017  
Published in USA, December 1, 2017  
5989-5470EN  
www.keysight.com  

相关型号:

DSO6054L

Low-Profile Oscilloscopes
KEYSIGHT

DSO751S

SMD Crystal Oscillators
ETC

DSO751SA

SMD Crystal Oscillators
ETC

DSO751SB

SMD Crystal Oscillators
ETC

DSO90000A-01G

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-100

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-1A7

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-1CM

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-200

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-20M

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-500

Infiniium 90000 Series Oscilloscopes
KEYSIGHT

DSO90000A-50M

Infiniium 90000 Series Oscilloscopes
KEYSIGHT