DSOXT3CXPI [KEYSIGHT]

X-Series Oscilloscopes;
DSOXT3CXPI
型号: DSOXT3CXPI
厂家: Keysight Technologies    Keysight Technologies
描述:

X-Series Oscilloscopes

文件: 总26页 (文件大小:2792K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Keysight Technologies  
Serial Bus Options for InfiniiVision  
X-Series Oscilloscopes  
Data Sheet  
Introduction  
Serial buses are pervasive in today’s digital designs and are used for a variety of purposes including on-  
board chip-to-chip communication, CPU to peripheral control, as well as for remote sensor data transfer  
and control.  
Without intelligent oscilloscope serial bus triggering and protocol decode, it can be difficult to debug  
these buses and correlate data transfers with other mixed signal interactions in your system. Keysight  
Technologies, Inc. InfiniiVision X-Series oscilloscopes (DSOs) and mixed-signal oscilloscopes (MSOs) offer  
optional integrated serial bus triggering and hardware-based protocol decoding solutions that give you the  
tools you need to accelerate debug of your designs that include serial bus communication.  
Supported Protocols and Features  
– I2C  
– SPI  
– RS232/UART  
– CAN  
– CAN FD (except 2000 X-Series)  
– CAN-dbc symbolic decode and trigger (except 2000 X-Series)  
– LIN  
– LIN-ldf symbolic decode and trigger (except 2000 X-Series)  
– SENT (3000T, 4000 and 6000 X-Series only)  
– CXPI (3000T and 4000 X-Series only)  
– FlexRay (except 2000 X-Series)  
– USB 2.0 low- and full-speed (4000 and 6000 X-Series)  
– USB 2.0 hi-speed (4000 and 6000 X-Series only)  
– USB 2.0 signal quality (4000 and 6000 X-Series only)  
– I2S (except 2000 X-Series)  
– MIL-STD 1553 (except 2000 X-Series)  
– ARINC 429 (except 2000 X-Series)  
– Hardware-based decoding  
– Multi-bus analysis (except 2000 X-Series)  
– Automatic search and navigation  
– Compatibility with segmented memory acquisition  
– Eye-diagram mask files available for CAN, FlexRay, MIL-STD 1553, and ARINC 429 (requires  
DSOX2MASK/DSOX3MASK/DSOX4MASK/DSOX6MASK mask test option)  
– FlexRay physical layer conformance test software (except 2000 X-Series)  
03 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Hardware-Based Decoding  
Automatic Search and Navigation  
Figure 1. Hardware-based decoding quickly reveals serial communication  
errors.  
Figure 3. Automatic “Search &  
Navigation” quickly finds user-  
specified serial bus frames/bytes of  
interest.  
Keysight’s InfiniiVision Series oscilloscopes are the industry’s only  
Keysight’s InfiniiVision Series oscilloscopes are the industry’s only  
scopes to use hardware-based decoding. Most other vendor’s  
scopes with serial bus triggering and protocol decode, use  
software post-processing techniques to decode serial packets/  
frames. With these software techniques, waveform- and decode-  
update rates tend to be slow (sometimes seconds per update.)  
That’s especially true when using deep memory, which is often  
required to capture multiple packetized serial bus signals. And  
when analyzing multiple serial buses simultaneously, software  
techniques can make decode update rates even slower.  
After capturing a long record of serial bus communication using  
the InfiniiVision scope’s MegaZoom deep memory, you can  
easily perform a search operation based on specific criteria  
that you enter. Then, you can quickly navigate to bytes/frames  
of serial data that satisfy the entered search criteria. Figure 3  
shows an example of searching on captured I2C data to find all  
occurrences of Read or Write operations with “No Ack.” In this  
case, the scope found five occurrences of data transfers with “No  
Ack,” and marked each occurrence with a white triangle to show  
where in time they happened relative to the captured waveform.  
Navigating and zooming-in on each marked byte/frame is quick  
and easy using the scope’s front panel navigation keys. Search  
and Navigation not available for DSOXT3CXPI/DSOX4CXPI.  
Faster decoding with hardware-based technology enhances  
scope usability, and more importantly, the probability of  
capturing infrequent serial communication errors. Figure 1 shows  
an example of a Keysight InfiniiVision X-Series scope capturing  
a random and infrequent CAN error frame. The upper half of the  
scope’s display shows the decoded data in a “Lister” format,  
along with a time-correlated decode trace shown below the  
waveform.  
Symbolic Trigger and Decode  
With the DSOXT3AUTO, DSOX4AUTO or DSOX6AUTO option  
licensed on a 3000T, 4000 or 6000 X-Series oscilloscope, you  
can import a .dbc file that defines your multi-node CAN network.  
The oscilloscope can then trigger on and decode the CAN bus  
symbolically as shown in Figure 2. LIN symbolic trigger and  
decode is also supported on the 3000T, 4000, and 6000 X-Series  
oscilloscopes by importing an industry-standard .ldf file.  
Figure 2. Symbolically decoding the CAN bus.  
04 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Multi-bus Analysis  
Using Segmented Memory to Capture  
Multiple Serial Bus  
Figure 4. An interleaved “Lister” makes it easier to time-correlate activity  
between two decoded serial buses.  
Figure 5. Segmented memory acquisition selectively captures more  
packets/bytes of serial bus activity.  
Many of today’s designs include multiple serial buses. Sometimes  
it may be necessary to correlate data from one serial bus to  
another. Keysight’s InfiniiVision 3000, 4000 and 6000 X-Series  
oscilloscopes can decode two serial buses simultaneously using  
hardware-based decoding. Plus they are the only scopes on  
the market that can also display the captured data in a time-  
interleaved “Lister” display, as shown in Figure 4. In this particular  
example, the scope has simultaneously decoded and interleaved  
a CAN and LIN bus in an automotive system.  
PacketsThe segmented memory option for Keysight’s InfiniiVision  
X-Series oscilloscopes (standard in 3000T, 4000 and 6000  
X-Series) can optimize your scope’s memory, letting you  
capture more packets/frames of serial bus activity. Segmented  
memory acquisition optimizes the number of packetized serial  
communication frames that can be captured consecutively.  
Segmented memory does this by capturing just the selective  
frames/bytes of interest while ignoring (not digitizing) idle time  
and other unimportant frames/bytes. Figure 5 shows an example  
of the oscilloscope capturing 500 consecutive hi-speed USB split  
packets for a total acquisition time of approximately  
200 ms. Capturing this much data using conventional  
oscilloscope acquisition memory would require 1G bytes of  
memory.  
Keysight’s InfiniiVision X-Series oscilloscopes are the only  
scopes on the market today that can acquire segments on up  
to four analog channels of acquisition, and time-correlated  
segments on digital channels (using an MSO model), along with  
automatic hardware-based serial bus decoding for each segment.  
In addition, you can use the scope’s Search and Navigation  
capability after a segmented memory acquisition has been  
performed.  
05 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Serial Bus Eye-diagram and Pulse Mask Testing  
With the addition of the DSOX2MASK, DSOX3MASK, DSOX4MASK or DSOX6MASK mask test option, which can perform over 200,000  
pass/fail tests (50,000 on 2000 X-Series) per second, you can perform eye-diagram and pulse mask testing on CAN signals on all  
InfiniiVision X-Series oscilloscopes. Eye-diagram mask testing on FlexRay, MIL-STD 1553, and ARINC 429 signals can be performed  
using an InfiniiVision 3000, 4000 or 6000 X-Series oscilloscope. Eye-diagram measurements provide a comprehensive signal quality  
test of the integrity of your transmitted and received signals. Keysight provides various mask files that you can download at no charge.  
The mask files are based on published industry mask standards and/or derived from physical layer/electrical specifications.  
The following CAN mask files are available:  
– 125 kbps – 400 meters  
– 250 kbps – 200 meters  
– 500 kbps – 10 meters  
– 500 kbps – 80 meters  
– 800 kbps – 40 meters  
– 1000 kbps – 25 meters  
Mask files for CAN FD are also available (3000, 4000, and 6000  
X-Series only). CAN FD eye-diagrams are based on the first  
10 bits of the FD phase from all frames.  
Figure 6. CAN 500 kbps mask test on 10 meter system.  
The following FlexRay mask test files are available:  
– TP1 standard voltage (10 Mbps only)  
– TP1 increased voltage (10 Mbps only)  
– TP11 standard voltage (10 Mbps only)  
– TP11 increased voltage (10 Mbps only)  
– TP4 10 Mbps  
– TP4 5 Mbps  
– TP4 2.5 Mbps  
Figure 7. FlexRay TP4 eye-diagram mask test.  
The following MIL-STD 1553 mask test files are available:  
– System xfmr-coupled Input  
– System direct-coupled Input  
– BC xfmr-coupled Input  
– BC direct-coupled Input  
– RT xfmr-coupled Input  
– RT direct-coupled Input  
Figure 8. MIL-STD 1553 BC to RT xfrm-coupled input mask test reveals a  
shifted bit that violates the pass/fail mask.  
06 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Serial Bus Eye-diagram and Pulse Mask Testing  
The following ARINC 429 mask/pulse test files are available:  
– 100 kbps Eye Test  
– 100 kbps 1’s Pulse Test  
– 100 kbps 0’s Pulse Test  
– 100 kbps Null Level Test  
– 12.5 kbps Eye Test  
– 12.5 kbps 1’s Pulse Test  
– 12.5 kbps 0’s Pulse Test  
– 12.5 kbps Null Level Test  
For additional information about eye-diagram mask testing on  
CAN, FlexRay, MIL-STD 1553, and ARINC 429 signals, refer to the  
application notes listed at the end of this document.  
Figure 9. ARINC 429 100 kbps eye-diagram mask test.  
Automated Physical Layer Conformance  
Testing  
To perform USB 2.0 signal quality testing based on USB-IF  
compliance standards, Keysight offers the DSOX4USBSQ or  
DSOX6USBSQ options on InfiniiVision 4000 or 6000 X-Series  
oscilloscopes. Figure 10 shows an example of the USB 2.0  
real-time eye test. Also included with this option is complete  
signal quality test report generation in HTML format. To see the  
complete list of supported tests, refer to the DSOX4USBSQ/  
DSOX6USBSQ signal quality test option data sheet listed at the  
ended of this document.  
To perform physical layer conformance testing on the differential  
FlexRay bus, Keysight provides a PC-based software package  
that you can download from Keysight’s website at no additional  
charge. If the InfiniiVision X-Series scope is licensed with the  
FlexRay, mask test, and segmented memory, you can perform  
automated physical layer tests at either receiver input or  
Figure 10. USB 2.0 signal quality eye test based on USB-IF physical layer  
compliance standards.  
transmitter output test points. Figure 10 shows an example of the  
generated report from a signal integrity voting test on a 10-Mbs  
isolated “1” pulse. The test report includes comprehensive pass/  
fail and margin analysis based on published specifications.  
Refer to the tables in the Specifications/Characteristics section  
of this document on page 17 to see the entire list of 33 available  
FlexRay tests that can be selected and performed using the  
FlexRay physical layer conformance test software package.  
Figure 11. FlexRay signal integrity voting test performed on an isolated  
“1” bit.  
07 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Probing Differential Serial Buses  
Many of today’s serial buses are based on differential signaling including USB, CAN, CAN FD, FlexRay, MIL-STD 1553, and ARINC 429.  
In addition, serial buses based on the RS232/UART protocol are often differential if implemented with RS422 or RS485 output drivers/  
transceivers. Keysight offers a wide range of differential active probes compatible with the InfiniiVision X-Series oscilloscopes for  
various bandwidth and dynamic range applications. Table 1 shows the differential probes that Keysight recommends for each of the  
listed differential serial buses.  
Table 1. Recommended probes for differential buses  
Differential bus (max bit rate)  
CAN (1 Mbps)  
CAN FD (10 Mbps data phase)  
FlexRay (10 Mbps)  
MIL-STD 1553 (1 Mbps)  
ARINC 429 (100 kbps)  
RS422/RS485 (10 Mbps)  
Hi-speed USB (480 Mbps)  
N2791A (25-MHz bandwidth)  
X
N2818A 1 (200-MHz bandwidth)  
N2750A (1.5-GHz bandwidth)  
X
X
X
X
X
X
X
X
X
X
1. The N2818A differential probe is not compatible with Keysight’s InfiniiVision 2000 X-Series oscilloscopes.  
If you need to connect to DB9-SubD connectors on your  
differential CAN, CAN FD and/or FlexRay bus, Keysight also offers  
the CAN/FlexRay DB9 probe head (part number 0960-2926) is  
shown in the inset picture of Figure 12.  
When probing differential signals inside of environmental  
chambers at extreme temperatures, Keysight offers the N7013A  
extreme temperature extension kit shown in Figure 13. The  
N7013A is compatible with the N2791A and N2818A differential  
probes and can operate in temperatures ranging from -40  
degrees to +85 degree Celsius. To learn more about this probing  
solution, refer the Extreme Temperature Probing Solutions  
selection guide (publication number 5991-3504EN) listed at the  
end of this document.  
Figure 12. Keysight’s N2818A 200-MHz differential active probe.  
The N2750A differential active probe shown in Figure 14, which is  
recommended for hi-speed USB 2.0 measurement applications,  
is based on Keysight’s InfiniiMode technology. With the press of  
a button, you can quickly toggle between viewing the differential  
signal, high-side signal, low-side signal, or the common mode  
signal on the USB 2.0 hi-speed bus without moving probe  
connections.  
Figure 14. Keysight’s N2750A 1.5-GHz InfiniiMode differential active  
probe.  
Figure 13. The N7013A extreme temperature probing kit for differential  
probes.  
08 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics  
I2C specifications/characteristics (DSOX2EMBD, DSOX3EMBD, and DSOX4EMBD  
Clock and data input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 (3000, 4000 and 6000 X-Series only)  
Up to 3.4 Mbps  
Start condition  
Max clock/data rate  
Triggering  
Stop condition  
Missing acknowledge  
Address with no acknowledge  
Restart  
EEPROM data read  
Frame (Start:Addr7:Read:Ack:Data)  
Frame (Start:Addr7:Write:Ack:Data)  
Frame (Start:Addr7:Read:Ack:Data:Ack:Data2)  
Frame (Start:Addr7:Write:Ack:Data:Ack:Data2)  
10-bit write  
Hardware-based decode  
Data (HEX digits in white)  
Address decode size: 7 bits (excludes R/W bit) or 8 bits (includes R/W bit)  
Read address (HEX digits followed by “R” in yellow)  
Write address (HEX digits followed by “W” in light-blue)  
Restart addresses (“S” in green, followed by HEX digits, followed by “R” or “W”)  
Acknowledges (suffixes “A” or “~A” in the same color as the data or address preceding it)  
Idle bus (mid-level bus trace in dark blue)  
Active bus (bi-level bus trace in dark blue)  
Unknown/error bus (bi-level bus trace in red)  
I2C plus one other serial bus, including another I2C bus. (3000, 4000 and 6000 X-Series only)  
Multi-bus analysis  
09 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
SPI specifications/characteristics (DSOX2EMBD, DSOX3EMBD, DSOX4EMBD and DSOX6EMBD)  
MOSI, MISO, Clock, and CS input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 (3000, 4000 and 6000 X-Series only)  
Up to 25 Mb/s  
4- to 64-bit data pattern during a user-specified framing period  
Framing period can be a positive or negative chip select (CS or ~CS) or clock idle time (timeout)  
Number of decode traces: 2 independent traces (MISO and MOSI)  
Data (hex digits in white)  
Unknown/error bus (bi-level bus trace in red)  
Number of clocks/packet (“XX CLKS” in light-blue above data packet)  
Idle bus (mid-level bus trace in dark blue)  
Max clock/data rate  
Triggering  
Hardware-based decode  
Multi-bus analysis  
Active bus (bi-level bus trace in dark blue)  
SPI plus one other serial bus, excluding another SPI bus. (3000, 4000 and 6000 X-Series only)  
10 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
RS232/UART specifications/characteristics (DSOX2COMP, DSOX3COMP, DSOX4COMP and DSOX6COMP)  
Tx and Rx input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 (3000, 4000 and 6000 X-Series only)  
Bus configuration  
Baud rates  
Number of bits  
Parity  
Polarity  
Bit order  
100 b/s up to 8 Mb/s  
5 to 9  
None, odd, or even  
Idle low or idle high  
LSB out first or MSB out first  
Rx start bit  
Triggering  
Rx stop bit  
Rx data  
Rx 1:data (9-bit format)  
Rx 0:data (9-bit format)  
Rx X:data (9-bit format)  
Rx or Tx parity error  
Tx start bit  
Tx stop bit  
Tx data  
Tx 1:data (9-bit format)  
Tx 0:data (9-bit format)  
Tx X:data (9-bit format)  
Burst (nth frame within burst defined by timeout)  
Hardware-based decode  
Number of decode traces  
Data format  
2 independent traces (Tx and Rx)  
Binary, hex, or ASCII-code characters  
Data byte display  
Idle bus trace  
White characters if no parity error, red characters if parity or bus error  
Mid-level bus trace in blue  
Active bus trace  
Multi-bus analysis  
Bi-level trace in blue  
RS232/UART plus one other serial bus, including another RS232/UART bus. (3000, 4000 and 6000 X-Series  
only)  
Totalize/counter function  
Total received frames  
Total transmitted frames  
Total parity error frames (with percentage)  
11 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
USB 2.0 low- and full-speed specifications/characteristics (DSOX4USBFL and DSOX6USBFL)  
USB input source (D+ & D-)  
Analog channels 1, 2, 3, 4  
Digital channels D0-D15  
Speed  
Low (1.5 Mb/s) and Full (12 Mb/s)  
Triggering  
Start of packet (SOP)  
End of packet (EOP)  
Suspend – when bus is idle for > 3 ms  
Resume – when exiting an idle state > 10 ms  
Reset – when SE0 is > 10 ms  
Token packet with specified content  
Data packet with specified content  
Handshake packet with specified content  
Special packet with specified content  
All errors – any of the below error conditions  
PID error – if packet type field does not match check field  
CRC5 error – if 5 bit CRC error is detected  
CRC16 error – if 16 bit CRC error is detected  
Glitch error – if two transitions occur in half a bit time  
Bit stuff error – if >6 consecutive “ones” are detected  
SE1 error – if SE1 > 1 bit time  
Hardware-based decode  
Base format  
Token packets (excluding SOF, 3 bytes)  
Hex, Binary, ASCII, or Decimal data decode  
PID (yellow, “OUT”, “IN”, “SETUP”, “PING”)  
PID Check (yellow when valid, red when error detected) – numeric value  
Address (blue, 7 bits)  
Endpoint (green, 4 bits)  
CRC (blue when valid, red when error detected, 5 bits)  
PID (yellow, “SOF”)  
Token packets (SOF, 3 bytes)  
PID Check (yellow when valid, red when error detected, 5 bits)  
Frame (green, 11-bits) – the frame number  
CRC (blue when valid, red when error detected, 5 bits)  
PID (yellow, “DATA0”, “DATA1”, DATA2”, “MDATA”)  
PID Check (yellow when valid, red when error detected, 16 bits)  
PID (yellow, “ACK”, “NAK”, “STALL”, “NYET”, “PRE”, “ERR”)  
PID Check (yellow when valid, read when error detected) – numeric value  
Hub Addr (green, 7 bits)  
Data packets (3 to 1027 bytes)  
Handshake packets (1 byte)  
SC (blue, 1 bit)  
Port (green, 7 bits)  
S & E|U (blue, 2 bits)  
ET (green, 2 bits)  
CRC (blue when valid, red when error detected, 5 bits  
USB low-full-speed plus one other serial bus (including another USB bus)  
Multi-bus analysis  
12 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
USB 2.0 high-speed specifications/characteristics (DSOX4USBH and DSOX6USBH)  
USB differential input source  
Analog channels 1, 2, 3, 4 (using a differential active probe)  
Speed  
High (480 Mb/s)  
Triggering  
Token packet with specified content  
Data packet with specified content  
Handshake packet with specified content  
Special packet with specified content  
All errors – any of the below error conditions  
PID error – if packet type field does not match check field  
CRC5 error – if 5 bit CRC error is detected  
CRC16 error – if 16 bit CRC error is detected  
Glitch error – if two transitions occur in half a bit time  
Hardware-based decode  
Base format  
Token packets (excluding SOF, 3 bytes)  
Hex, Binary, ASCII, or Decimal data decode  
PID (yellow, “OUT”, “IN”, “SETUP”, “PING”)  
PID check (yellow when valid, red when error detected) – numeric value  
Address (blue, 7 bits)  
Endpoint (green, 4 bits)  
CRC (blue when valid, red when error detected, 5 bits)  
PID (yellow, “SOF”)  
Token packets (SOF, 3 bytes)  
Data packets (3 to 1027 bytes)  
PID check (yellow when valid, red when error detected, 5 bits)  
Frame (green, 11-bits) – the frame number  
CRC (blue when valid, red when error detected, 5 bits)  
PID (yellow, “DATA0”, “DATA1”, DATA2”, “MDATA”)  
PID check (yellow when valid, red when error detected, 16 bits)  
PID (yellow, “ACK”, “NAK”, “STALL”, “NYET”, “PRE”, “ERR”)  
PID check (yellow when valid, read when error detected) – numeric value  
Hub Addr (green, 7 bits)  
Handshake packets (1 byte)  
SC (blue, 1 bit)  
Port (green, 7 bits)  
S & E|U (blue, 2 bits)  
ET (green, 2 bits)  
CRC (blue when valid, red when error detected, 5 bits  
N/A  
Multi-bus analysis  
13 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
CAN specifications/characteristics (DSOX2AUTO and DSOX3AUTO)  
CAN input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 non-differential. (3000 X-Series only)  
Rx, Tx, CAN_L, CAN_H, Diff (L-H), Diff (H-L)  
10 kb/s up to 5 Mb/s  
Signal types  
Baud rates  
Triggering  
Start-of-frame (SOF)  
Remote frame ID (RMT)  
Data frame ID (~RMT)  
Remote or data frame ID  
Data frame ID and data  
Error frame  
All errors (includes protocol “form” errors that may not generate flagged error frames)  
Acknowledge errors  
Overload frames  
ID length: 11 bits or 29 bits (extended)  
Frame ID (hex digits in yellow)  
Hardware-based decode  
Remote frame (RMT in green)  
Data length code (DLC in blue)  
Data bytes (hex digits in white)  
CRC (hex digits in blue = valid, hex digits in red = error)  
Error frame (bi-level bus trace and ERR message in red)  
Form error (bi-level bus trace and “?” in red)  
Overload frame (“OVRLD” in blue)  
Idle bus (mid-level bus trace in dark blue)  
Active bus (bi-level bus trace in dark blue)  
CAN plus one other serial bus, including another CAN bus. (3000 X-Series only)  
Total frames, total overload frames, total error frames, bus utilization (bus load)  
Various downloadable mask files available based on differential probing polarity, baud rate, and network  
length  
Multi-bus analysis  
Totalize function  
Eye-diagram mask testing (3000 X-Series  
only, requires DSOX3MASK)  
14 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
CAN/CAN FD specifications/characteristics (DSOXT3AUTO, DSOX4AUTO, and DSOX6AUTO)  
Note: “Classic” CAN 2.0 is a subset of CAN FD. CAN FD trigger and decode supports ISO and non-ISO CAN FD specifications. Both of these protocol  
standards are supported with the DSOXT3AUTO, DSOX4AUTO, and DSOX6AUTO option in an InfiniiVision 3000T, 4000, and 6000 X-Series oscilloscope.  
CAN input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 non-differential  
Rx, Tx, CAN_L, CAN_H, Diff (L-H), Diff (H-L)  
10 kb/s up to 5 Mb/s  
10 kb/s up to 10 Mb/s  
SOF (Start-of-frame)  
Signal types  
Standard baud rates  
FD baud rates  
Triggering  
EOF (End-of-frame, filtered by ID)  
Data frame ID (11 bits or 29 bits: Extended)  
Data frame ID and data – non FD  
Data frame ID and data - FD  
Remote frame ID (RTR)  
Remote or data frame ID  
Error frame (filtered by ID)  
Acknowledge error (filtered by ID)  
Form error (filtered by ID)  
Stuff error (filtered by ID)  
CRC error (filtered by ID)  
Spec error (includes Ack, Form, Stuff, or CRC error; filter by ID)  
All errors (includes any Spec error or Error frame; filtered by ID)  
BRS bit (filtered by ID of FD frames only)  
CRC delimiter bit (filtered by ID of FD frames only)  
ESI bit active (filtered by ID of FD frames only)  
ESI bit passive (filtered by ID of FD frame only)  
Overload frames  
Symbolic triggering (based on .dbc file)  
Message names  
Message and signal values/encoded states (first 8 bytes)  
Hardware-based decode  
Frame ID (hex digits in yellow)  
Remote frame (RMT in green)  
Data length code (DLC = with decimal digits in blue)  
Data bytes (hex digits in white)  
ESI bit passive (frame type column in lister shaded yellow; FD frames only)  
Error frame (bi-level red bus trace with ERR FRAME in red)  
Stuff bit error (bi-level red bus trace with STUFF ERR in red)  
Form error (bi-level red bus trace with FORM ERR in red)  
Acknowledge error (bi-level red bus trace with ACK ERR in red)  
CRC (hex digits in blue = valid, hex digits in red = error)  
Overload frame (“OVRLD” in blue)  
Idle bus (mid-level dark blue bus trace)  
Active bus (bi-level dark blue bus trace with embedded decode within)  
Symbolic decode (based on .dbc file)  
Message names (alpha-numeric characters in yellow)  
Signal names, value/encoded state (first 8 bytes), and units (alpha-numeric characters in white)  
CAN/CAN FD plus one other serial bus, including another CAN/CAN FD bus  
Total frames, total error frames with %, total spec errors, bus load in %  
Various downloadable mask files available based on differential probing polarity, baud rate, and network  
length  
Multi-bus analysis  
Totalize function (real time)  
CAN/CAN FD Eye-diagram mask testing  
(requires DSOX3MASK/DSOX4MASK/  
DSOX6MASK)  
15 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
LIN specifications/characteristics (DSOX2AUTO, DSOX3AUTO, DSOXT3AUTO, DSOX4AUTO and DSOX6AUTO)  
LIN input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 except 2000 X-Series  
LIN 1.3 or LIN 2.X  
2400 b/s to 625 kb/s  
LIN standards  
Baud rates  
Triggering  
Sync break  
Frame ID (0X00HEX to 0X3FHEX)  
Frame ID and data  
Parity error  
Checksum error  
Symbolic decode (except 2000X)(based on  
.ldf file)  
Hardware-based decode  
Message names (alpha-numeric characters in yellow)  
Signal names, value/encoded state and units (alpha-numeric characters in white)  
Frame ID (6-bit hex digits in yellow)  
Frame ID and optional parity bits (8-bit hex digits in yellow if valid, red if parity bit error)  
Data bytes (hex digits in white)  
Check sum (hex digits in blue = valid, hex digits in red = error)  
Sync error (“SYNC” in red)  
THeader-max (“THM” in red)  
TFrame-max (“TFM” in red)  
Parity error (“PAR” in red)  
LIN 1.3 wake-up error (“WUP” in red)  
Idle bus (mid-level bus trace in dark blue)  
Active bus (bi-level bus trace in dark blue)  
Symbolic triggering (except 2000X) (based on Message names  
.dbc file)  
Message and signal values/encoded states  
Multi-bus analysis  
LIN plus one other serial bus, including another LIN bus. (except 2000X)  
16 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
SENT specifications/characteristics (DSOXT3SENSOR, DSOX4SENSOR, and DSOX6SENSOR)  
CAN input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15 non-differential  
Clock period  
Number of nibbles  
Idle state  
1 µs to 300 µs with user-defined tolerance setting from 3 to 30%  
1 to 6  
High or low  
CRC format  
2008 or 2010 standards  
Pause pulse  
On/Off  
Message format  
Fast Nibbles (All)  
Fast Signals (only)  
Fast + Short Serial  
Fast + Enhanced Serial (automatically detects bit format: 12-bit data/8-bit ID or 16-bit data/4-bit ID)  
Short Serial (only)  
Enhanced Serial (only)  
Number of defined signals  
Numerical format of signals  
1 to 6 (each specified by start bit #, number of bits, and nibble order)  
Hexadecimal, unsigned decimal, or transfer function with user-defined multiplier and offset for each  
defined signal  
Triggering  
Start of fast channel message  
Start of slow channel message  
Fast channel status & communication nibble + data  
Slow channel message ID  
Slow channel message ID + data  
Tolerance violation (sync pulse width exceeds user-specified tolerance)  
Fast channel CRC error  
Slow channel CRC error  
All CRC errors  
Pulse period error (if nibbles are < 12 or > 27 ticks wide)  
Successive sync pulses error (if consecutive sync pulse widths are greater than 1/64 difference)  
Status & communication nibble (binary digits in green)  
Data (hex, unsigned decimal, or transfer function digits in white based on user-defined signal format)  
CRC error (hex digit in blue = valid, hex digit in red = error)  
Pulse period error (< or > in red)  
Fast channel decode  
Slow channel decode  
Multi-bus analysis  
Message ID (hex digits in yellow)  
Data (hex digits in white)  
CRC (hex digits in blue = valid, hex digits in red = error)  
SENT plus one other serial bus, including another SENT bus  
17 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
CXPI specifications/characteristics (DSOXT3CXPI and DSOX4CXPI)  
CXPI input source  
Baud rates  
Triggering  
Analog channels 1, 2, 3 or 4  
9.6 kb/s to 40 kb/s (20 kb/s typical) with tolerance setting  
SOF (Start-of-frame)  
EOF (End-of-frame)  
PTYPE  
Frame ID (PTPYE present or not present)  
Frame ID + info + data  
Frame ID + info + data (long frame)  
CRC field error (filtered by ID)  
Parity error  
Inter-byte space error (filtered by ID)  
Inter-frame space error (filtered by ID)  
Framing error (filtered by ID)  
Data length error (filtered by ID)  
Sample error  
All errors  
Sleep frame  
Wakeup pulse  
Hardware-based decode  
Frame ID (hex digits in yellow if valid or red if parity error)  
Data length code (DLC = with decimal digits in blue)  
Network management (NM) bits (binary digits in green)  
Counter (CT) bits (binary digits in yellow)  
Data (hex digits in white)  
CRC (hex digits in blue = valid, hex digits in red = error)  
Idle bus (mid-level dark blue bus trace)  
Active bus (bi-level dark blue bus trace with embedded decode within)  
Inter-byte space error (IBS ERR in red)  
Data length error (LEN ERR in red)  
Sleep mode (SLEEP MODE in orange within bi-level orange bus trace)  
Wakeup pulse (WAKEUP PULSE in blue with bi-level blue bus trace)  
CXPI plus one other serial bus  
Multi-bus analysis  
18 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
FlexRay specifications/characteristics (DSOX3FLEX, DSOX4FLEX and DSOX6FLEX)  
FlexRay input source  
FlexRay channels  
Baud rates  
Channel 1, 2, 3, or 4 (using differential probe)  
A or B  
2.5 Mbps, 5.0 Mbps, and 10 Mbps  
Frame type: Startup (SUP), not startup (~SUP), sync (SYNC), not sync (~SYNC), null (NULL), not null  
(~NULL), normal (NORM), and All  
Frame triggering  
Frame ID: 1 to 2047 (decimal format), and All  
Cycle -  
Base: 0 to 63 (decimal format), and All  
Repetition: 1, 2, 4, 8, 16, 32, 64 (decimal format), and All  
All errors  
Header CRC error  
Frame CRC error  
Error triggering  
Event triggering  
Wake-up  
TSS (transmission start sequence)  
BSS (byte start sequence)  
FES/DTS (frame end or dynamic trailing sequence)  
Frame type (NORM, SYNC, SUP, NULL in blue)  
Frame ID (decimal digits in yellow)  
Payload-length (decimal number of words in green)  
Header CRC (hex digits in blue if valid, or red digits if invalid)  
Cycle number (decimal digits in yellow)  
Data bytes (HEX digits in white)  
Frame decoding  
Frame CRC (hex digits in blue if valid, or red digits  
Total frames  
Totalize function  
Total synchronization frames  
Total null frames  
Eye-diagram mask testing (requires  
DSOX3MASK mask test option plus  
downloadable mask files)  
TP1 standard voltage (10 Mbps only)  
TP1 increased voltage (10 Mbps only)  
TP11 standard voltage (10 Mbps only)  
TP11 increased voltage (10 Mbps only)  
TP4 10 Mbps, TP4 5 Mbps and TP4 2.5 Mbps  
FlexRay plus one other serial bus (including another FlexRay bus)  
Multi-bus analysis  
19 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
FlexRay Physical Layer Conformance Test software  
Requires FlexRay option (DSOX3FLEX/DSOX4FLEX/DSOX6FLEX)  
Mask test option (DSOX3MASK/DSOX4MASK/DSOX6MASK)  
Segmented memory option (DSOX3SGM or standard on 3000T, 4000 and 6000 X-Series)  
Table 1. Receiver input tests  
Parameter tested  
Eye-diagram mask tests:  
TP4 – All  
Test description  
Receiver mask test on all frames  
TP4 – ID  
Receiver mask test on specified frame  
Signal integrity voting tests on 13 MHz low-pass filtered Isolated “1”:  
uData1Top  
dBitShort  
dBitLengthVariation  
dEdge01  
dEdge10  
dEdgeMax  
Sq1  
Required maximal level  
Shortest single bit  
Bit asymmetry  
Rising edge duration (-300 mV to +300 mV)  
Falling edge duration (+300 mV to -300 mV)  
Slowest edge  
Isolated “1” voted signal quality  
Signal integrity voting tests on 13 MHz low-pass filtered Isolated “0”:  
uData0Top  
dBitShort  
Required minimal level  
Shortest single bit  
dBitLengthVariation  
dEdge01  
dEdge10  
Bit asymmetry  
Rising edge duration (-300 mV to +300 mV)  
Falling edge duration (+300 mV to -300 mV)  
Slowest edge  
dEdgeMax  
Sq0  
Isolated “0” voted signal quality  
Advanced diagnostic tests:  
gdTSSTransmitter  
MCT  
uBusRx-Data  
-uBusRx-Data  
uRx-Idle  
Transmitted TSS width @ receiver  
Mean corrected cycle time  
Data 1 amplitude  
Data 0 amplitude  
Mean idle level  
dBusRx01  
dBusRx10  
Rise time Data0 to Data1 (–300 mV to +300 mV)  
Fall time Data1 to Data0 (+300 mV to -300 mV)  
Table 2. Transmitter output tests  
Parameter tested  
Eye-diagram mask tests (10 Mbs only):  
TP1 – Std V  
TP1 – Incr V  
TP11 – Std V  
Test description  
Mask test on standard voltage bus driver output  
Mask test on increased voltage bus driver output  
Mask test on standard voltage active star output  
Mask test on increased voltage active star output  
P11 – Incr V  
Advanced diagnostic tests:  
gdTSSTransmitter  
uBusTx-Data  
Transmitted TSS width  
Data 1 amplitude  
-uBusTx-Data  
uRx-Idle  
Data 0 amplitude  
Mean idle level  
dBusTx01  
dBusTx10  
Rise time Data0 to Data1 (20 to 80%)  
Fall time Data1 to Data0 (80 to 20%)  
20 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
I2S specifications/characteristics (DSOX3AUDIO, DSOX4AUDIO, and DSOX6AUDIO)  
SCLK, WS, and SDATA input source  
Analog channels 1, 2, 3, or 4  
Digital channels D0 to D15  
Bus configuration:  
Transmitted word size  
Decoded/receiver word size  
Alignment  
Word select - low  
SCLK slope  
4 to 32 bits (user selectable)  
4 to 32 bits (user selectable)  
Standard, left-justified, or right-justified  
Left-channel or right-channel  
Rising edge or falling edge  
Decoded base  
Baud rates  
Hex (2’s complement) or signed decimal  
2400 b/s to 625 kb/s  
Triggering:  
Audio channel  
Trigger modes  
Audio left, audio right, or either  
= (Equal to entered data value)  
≠ (Not equal to entered data value)  
< (Less than entered data value)  
> (Greater than entered data value)  
>< (Within range of entered data values)  
<> (Out of range of entered data values)  
Increasing value that crosses armed (<=) and trigger (>=) entered data values  
Decreasing value that crosses armed (>=) and trigger (<=) entered data values  
Hardware-based decode:  
Left channel  
L: “decoded value” in white  
Right channel  
Error  
Word size indicator  
Multi-bus analysis  
R: “decoded value” in green  
ERR in red (mismatch between transmitted and received word size, or invalid input signaling)  
“# of TX / # of RX” CLKS in blue displayed above each decoded work  
I2S plus one other serial bus (excluding another I2S bus)  
21 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
MIL-STD 1553 specifications/characteristics (DSOX3AERO, DSOX4AERO, and DSOX6AERO)  
MIL-Std 1553 input source  
Triggering  
Analog channels 1, 2, 3, or 4 (using a differential active probe)  
Data word start  
Data word stop  
Command/status word start  
Command/status word stop  
Remote terminal address (hex)  
Remote terminal address (hex) + 11 bits (binary)  
Parity error  
Sync error  
Manchester error  
Color-coded, hardware-accelerated decode  
Base: HEX or binary  
Command or status word (“C/S” in green)  
Remote terminal address (hex or binary digits in green)  
11 Bits following RTA (hex or binary digits in green)  
Data word (“D” in white)  
Data word bits (hex or binary digits in white)  
Parity error (all decoded text in red)  
Synchronization error (“Sync” in red)  
Manchester error (“Manch“ in red)  
System xfmr-coupled input  
Eye-diagram mask testing (requires  
DSOX3MASK mask test option plus  
downloadable mask files)  
System direct-coupled input  
BC xfmr-coupled input  
BC direct-coupled input  
RT xfmr-coupled input  
RT xfmr-coupled input  
Multi-bus analysis  
MIL-STD 1553 plus one other serial bus, (including another MIL-STD 1553 bus)  
22 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Specifications/Characteristics (Continued)  
ARINC 429 specifications/characteristics (DSOX3AERO, DSOX4AERO and DSOX6AERO)  
ARINC 429 input source  
Analog channels 1, 2, 3, or 4 (using a differential active probe)  
High (100 kbps)  
Baud rates  
Triggering  
Low (12.5 kbps)  
Word start  
Word stop  
Label (octal)  
Label (octal) + bits (binary)  
Label range (octal)  
Parity error  
Word error  
Gap error  
Word or gap error  
All errors  
All bits (useful for eye-diagram testing)  
All 0 bits  
All 1 bits  
Color-coded, hardware-accelerated decode  
Word format: Label/SDI/data/SSM or label/data/SSM or label/data  
Label (octal digits in yellow)  
SDI (binary digits in blue)  
Data (hex or binary digits in white)  
SSM (binary digits in green)  
Errors (text in red)  
Totalize function  
Total words  
Total errors  
Eye-diagram and pulse mask testing (requires 100 kbps eye test  
DSOX3MASK plus downloadable mask files)  
100 kbps 1’s test  
100 kbps 0’s test  
100 kbps null test  
12.5 kbps eye test  
12.5 kbps 1’s test  
12.5 kbps 0’s test  
12.5 kbps null test  
Multi-bus analysis  
ARINC 429 plus one other bus (including another ARINC 429 bus)  
23 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Ordering Information  
The various serial bus options are compatible on most models of the Keysight InfiniiVision 3000, 4000 and 6000 X-Series  
oscilloscopes. The entry-level 2000 X-Series oscilloscopes support only the I2C/SPI, RS232/UART, and CAN/LIN options. Existing  
InfiniiVision X-Series oscilloscopes can also be upgraded with these options.  
For most model numbers, the number after DSOX tells you to which series of oscilloscope it applies. For example, DSOX2EMBD applies  
to the 2000 X-Series and DSOX3EMBD applies to the 3000 X-Series. “T” in the model number indicates that this option is available in  
the 3000T X-Series, but not in the 3000A X-Series.  
Model number  
DSOX2EMBD, DSOX3EMBD, DSOX4EMBD or  
DSOX6EMBD  
Description  
I2C and SPI trigger and decode  
DSOX2COMP, DSOX3COMP, DSOX4COMP or  
DSOX6COMP  
RS232/UART trigger and decode  
DSOX2AUTO or DSOX3AUTO  
DSOXT3AUTO, DSOX4AUTO, or DSOX6AUTO  
DSOXT3SENSOR, DSOX4SENSOR, or  
DSOX6SENSOR  
CAN and LIN trigger and decode  
CAN, CAN FD, and LIN trigger and decode, including CAN-dbc and LIN-ldf symbolic decoding  
Single Edge Nibble Transmission (SENT) trigger and decode  
DSOX3TCXPI or DSOX4CXPI  
DSOX3FLEX, DSOX4FLEX or DSOX6FLEX  
DSOX3AERO, DSOX4AERO or DSOX6AERO  
DSOX3AUDIO, DSOX4AUDIO or DSOX6AUDIO  
DSOX4USBFL or DSOX6USBFL  
DSOX4USBH or DSOX6USBH  
DSOX4USBSQ or DSOX6USBSQ  
DSOX2SGM and DSOX3SGM  
DSOX2MASK, DSOX3MASK, DSOX4MASK or  
DSOX6MASK  
Clock extension peripheral interface (CXPI) trigger and decode  
FlexRay trigger and decode  
MIL-STD 1553 and ARINC 429 trigger and decode  
I2S trigger and decode  
USB 2.0 low- and full-speed trigger and decode  
USB 2.0 hi-speed trigger and decode (1 GHz and 1.5 GHz bandwidth models of 4000 X-Series only)  
USB 2.0 signal quality test (hi-speed tests require 1.5 GHz bandwidth models)  
Segmented memory (standard on 3000T, 4000 and 6000 X-Series models)  
Mask test option  
N2791A  
25-MHz differential active probe  
N2818A  
200-MHz differential active probe  
N7013A  
N2750A  
0960-2926  
Extreme temperature probing kit for differential active probes  
1.5 GHz differential active probe (recommended for USB 2.0 hi-speed applications)  
DB9 probe head adapter for N2791A and N2818A  
Additional options and accessories are available for Keysight’s InfiniiVision oscilloscopes. Refer to the first four documents in the list  
below for ordering information about these additional options and accessories.  
24 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
Related Keysight Literature  
Publication title  
InfiniiVision 2000 X-Series Oscilloscopes - Data Sheet  
InfiniiVision 3000T X-Series Oscilloscopes - Data Sheet  
InfiniiVision 4000 X-Series Oscilloscopes - Data Sheet  
Publication number  
5990-6618EN  
5992-0140EN  
5991-1103EN  
5991-4087EN  
5968-8153EN  
5990-3504EN  
5990-4753EN  
5991-0560EN  
5991-1762EN  
5990-5817EN  
5991-1148EN  
5991-2847EN  
5991-0484EN  
5992-0437EN  
5991-4166EN  
5990-4923EN  
5990-9324EN  
5990-9325EN  
InfiniiVision 6000 X-Series Oscilloscopes - Data Sheet  
InfiniiVision Oscilloscope Probes and Accessories - Selection Guide  
Extreme Temperature Probing Solutions for Oscilloscope Measurements - Data Sheet  
N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes - Data Sheet  
N2750A/51A/52A InfiniiMode Differential Active Probes - Data Sheet  
DSOX4USBSQ and DSOX6USBSQ USB 2.0 Signal Quality Test Option for 4000 and 6000 X-Series - Data Sheet  
Using Oscilloscope Segmented Memory for Serial Bus Applications - Application Note  
Characterizing Hi-Speed USB 2.0 Serial Buses In Embedded Designs - Data Sheet  
Debug Automotive Designs Faster with CAN-dbc Symbolic Trigger and Decode - Application Note  
CAN Eye-Diagram Mask Testing - Application Note  
CAN FD Eye-Diagram Mask Testing - Application Note  
Characterizing CAN Bus Arbitration Using InfiniiVision 4000/6000 X-Series Oscilloscope - Application Note  
FlexRay Physical Layer Eye-diagram Mask Testing - Application Note  
MIL-STD 1553 Eye-diagram Mask Testing – Application Note  
ARINC 429 Eye-diagram and Pulse-shape Mask Testing – Application Note  
To download these documents, insert the publication number in the URL:  
http://cp.literature.keysight.com/litweb/pdf/xxxx-xxxxEN.pdf  
Product web site  
For the most up-to-date and complete application and product information, please visit our product Web sites at:  
www.keysight.com/find/2000X-Series  
www.keysight.com/find/3000TX-Series  
www.keysight.com/find/4000X-Series  
www.keysight.com/find/6000X-Series  
Keysight Oscilloscopes  
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications  
25 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
www.axiestandard.org  
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an  
open standard that extends the AdvancedTCA for general purpose and  
semiconductor test. The business that became Keysight was a founding  
member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo  
are registered US trademarks of the PCI Industrial Computer Manufacturers  
Group.  
www.lxistandard.org  
LAN eXtensions for Instruments puts the power of Ethernet and the Web  
inside your test systems. The business that became Keysight was a founding  
member of the LXI consortium.  
www.pxisa.org  
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a  
rugged, PC-based high-performance measurement and automation system.  
26 | Keysight | Serial Bus Options for InfiniiVision X-Series Oscilloscopes - Data Sheet  
For more information on Keysight  
Evolving  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Our unique combination of hardware, software, support, and people can help  
you reach your next breakthrough. We are unlocking the future of technology.  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
From Hewlett-Packard to Agilent to Keysight  
myKeysight  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
Other AP Countries  
Keysight Infoline  
Europe & Middle East  
Austria  
Belgium  
Finland  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
www.keysight.com/find/Infoline  
Keysight’s insight to best in class information management. Free access to  
your Keysight equipment company reports and e-library.  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
Keysight Services  
www.keysight.com/find/service  
Our deep offering in design, test, and measurement services deploys an  
industry-leading array of people, processes, and tools. The result? We help  
you implement new technologies and engineer improved processes that  
lower costs.  
KEYSIGHT  
SERVICES  
Three-Year Warranty  
www.keysight.com/find/ThreeYearWarranty  
Spain  
Sweden  
Switzerland  
Keysight’s committed to superior product quality and lower total cost  
of ownership. Keysight is the only test and measurement company with  
three-year warranty standard on all instruments, worldwide. And, we provide  
a one-year warranty on many accessories, calibration devices, systems and  
custom products.  
Opt. 2 (FR)  
Opt. 3 (IT)  
0800 0260637  
United Kingdom  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure your  
instruments are operating to specification, so you can rely on accurate  
measurements.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-06-08-16)  
Keysight Channel Partners  
www.keysight.com/find/channelpartners  
Get the best of both worlds: Keysight’s measurement expertise and product  
breadth, combined with channel partner convenience.  
DEKRA Certified  
ISO9001 Quality Management System  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
www.keysight.com/find/2000X-Series  
www.keysight.com/find/3000X-Series  
www.keysight.com/find/4000X-Series  
www.keysight.com/find/6000X-Series  
This information is subject to change without notice.  
© Keysight Technologies, 2012 - 2016  
Published in USA, June 9, 2016  
5990-6677EN  
www.keysight.com  

相关型号:

DSOXT3DVMCTR

InfiniiVision 3000T X- Series
KEYSIGHT

DSOXT3MSO

InfiniiVision 3000T X- Series
KEYSIGHT

DSOXT3SENSOR

InfiniiVision 3000T X- Series
KEYSIGHT

DSOZ204A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ254A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ334A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ504A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ592A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ594A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ632A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSOZ634A

Infiniium Z-Series Oscilloscopes
KEYSIGHT

DSP

DSP RELAYS
PANASONIC