Be Ready for Winter  
Features  
Operational down to –40 °C  
temperature  
Increase productivity with Blue-  
tooth® wireless  
connectivity  
– OLED display with 2000:1 contrast  
ratio and 160 degrees viewing angle3,4  
– 30,000-count resolution  
– Measure up to 1000 V AC and DC  
– Measure up to 10 A (20 A for 30 s)  
– Resistance, diode test, temperature,  
capacitance  
– Low Impedance mode2,3,4 and Low  
Pass Filter  
– Peak detection of up to 250 µs  
– Continuity test with beeper and back-  
light1,2  
The U1273AX OLED handheld digital  
multimeter, the latest addition to U1270  
Series, is capable of operating in winter  
weather down to –40°C temperature. Even  
in frigid conditions, the U1273AX enables  
you to achieve immediate and accurate  
results without the need to warm up in  
advance.  
For wireless connectivity to smartphones  
and tablets, the U1270 Series is compat-  
ible with the U1177A infrared-to-Bluetooth  
adapter for maximum efficiency and  
productivity in completing measure-  
ments tasks. Adding the optional U1177A  
to a U1270 Series you can easily perform  
remote monitoring and data  
logging via Android devices or Windows-  
based PC.  
– Seven readings/s measurement rate  
for voltage and current  
– Smooth function for accurately stable  
readings  
– Up to 10,000 points internal memory  
for data logging  
Bluetooth wireless connectivity with  
optional U1177A Bluetooth  
– PC connectivity with optional U1173A  
IR-USB cable  
IP 54 certified – water and dust resis-  
tant  
– CAT III 1000 V, CAT IV 600 V safety  
rating  
– Up to 3000m operating altitude  
– –40 to 55 °C operating temperature4  
OLED for more display clarity  
Designed with OLED display, you can ex-  
perience crystal-clear measurement read-  
ings with its outstanding 2000:1 contrast  
ratio. The display also allows wider viewing  
angles up to 160 degrees ensuring you get  
the right readings at the first glance even  
in poorly lit environments.  
1. U1271A  
2. U1272A  
3. U1273A  
4. U1273AX  
3 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Key Functions  
Water and dust resistance (IP54) High measurement rate at seven Up to 10,000 recording points  
readings per second for Voltage  
and Current  
for manual, auto and event log-  
ging  
The series’ tightly sealed design helps  
protect against water, dust and damage.  
Each handheld DMM is certified with IP 54  
ratings so that you can carry out tests and  
measurements with confidence, even in  
harsh working conditions.  
You can detect even the slightest change  
in your sensitive signals (Voltage and Cur-  
rent) with its high measurement rate capa- huge internal memory of up to 10,000  
bility. By clicking the resettable smooth  
function button, you may customize the  
readings’ sensitivity suitable for various  
tests.  
Record measurements on-the-go and  
transfer data to PC conveniently with the  
recording points. The GUI Data Logging  
software and optional U1173A IR-USB  
cable are required to transfer data or per-  
form real time data logging on a PC.  
Operational up to 3000  
meters altitude  
For high altitude applications such as  
wind farm maintenance, you can measure  
with confidence using the U1270 Series,  
capable of measuring up to 3000 meters  
above sea level.  
Visual alert for continuity test  
(for U1271A and U1272A only)  
Built-in Low Pass Filter  
The U1270 Series offers a 1 kHz LPF or  
Low Pass Filter to provide accurate Vari-  
able Frequency Drive (VFD) output mea-  
surements. This function eliminates high  
frequency noise and harmonics, ensuring  
motor filter efficiency.  
Continuity detection in noisy and dark  
environments is made easy with U1270  
Series’ loud beeper and flashing backlight  
that indicates continuity and thus im-  
proves safety.  
Figure 1. Comparison of voltage output from industrial motor VFD without and with Low Pass Filter functionality.  
4 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Key Functions  
Low impedance mode  
Peak detect at 250 µs  
Stray voltages are usually found in non-  
energized electrical wiring adjacent to  
powered wires due to capacitive or induc-  
tive coupling between these wires. The low  
impedance mode serves to eliminate false  
readings by dissipating these stray voltag-  
es thus improves safety and measurement  
efficiency during voltage measurement.  
The peak detect function allows you to  
capture the engine or motor startup tran-  
sient as fast as 250 µs.  
Figure 2. U1272A helps you identify the presence of stray voltage on a disconnected wire running parallel with the wire powering up the  
VFD to an industrial motor. The image on the right shows the U1272A in low impedance mode.  
5 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Front and Back Panel Description  
OLED display with 2000:1  
contrast ratio and 160  
degree viewing angle  
30,000 counts resolution  
Smart 1 removes residual  
Peak detect records tran-  
sients as fast as 250 μs  
voltage of up to 1000 mV  
Measure up to  
1000 V AC and DC  
Auto diode1 automatically  
determines diode polarity  
Low Pass Filter (LPF)  
removes unwanted high  
frequency signals  
Temperature measurement:  
J type thermocouple  
–210 to 1200 °C1, K type ther-  
mocouple –200 to 1732 °C  
ZLOW 1 provides both high  
and low impedance modes  
to eliminate stray voltages  
Measure up to 10 A  
(20 A for 30 s)  
Front panel  
1. U1272A, U1273A and U1273AX only  
Once connected to any HH DMM via Bluetooth adapter you are able to log and view measurements  
graphically from smart phones and tablets.  
6 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Front and Back Panel Description  
Hang hole  
Probe holder/storage  
IR-USB connectivity with  
optional IR-USB cable  
Slim, ergonomic design  
for better grip  
Easy fuse and battery  
access from battery cover  
beneath the stand  
Back panel  
7 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Choose Among These Four Models  
U1271A  
U1272A  
U1273A  
U1273AX  
Basic Features  
Display resolution  
Display  
30,000 counts  
30,000 counts  
30,000 counts  
30,000 counts  
LCD  
Yes  
AC  
LCD  
OLED  
N/A  
OLED  
N/A  
Backlight  
Yes  
True RMS  
AC + DC  
AC + DC  
AC + DC  
Measurements  
Voltage  
Up to 1000 V AC, DC  
0.05% + 2 counts  
Up to 1000 V AC, DC  
0.05% + 2 counts  
Up to 1000 V AC, DC  
0.05% + 2 counts  
Up to 1000 V AC, DC  
0.05% + 2 counts  
Basic dcV accuracy  
Up to 10 A  
(20 A for 30 s)  
Up to 10 A  
(20 A for 30 s)  
Up to 10 A  
(20 A for 30 s)  
Up to 10 A  
(20 A for 30 s)  
Current  
Resistance  
Up to 100 MΩ  
Up to 300 MΩ  
Up to 300 MΩ  
Up to 300 MΩ  
Frequency, capacitance,  
temperature, continuity,  
diode test  
Frequency, capacitance,  
temperature, continuity,  
diode test  
Frequency, capacitance,  
temperature, continuity,  
diode test  
Frequency, capacitance,  
temperature, continuity,  
diode test  
Other measurements  
AC bandwidth  
20 kHz  
Yes  
100 kHz  
Yes  
100 kHz  
Yes  
100 kHz  
Yes  
Low pass filter  
Low impedance mode  
Smart Ohm  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Safety and Regulatory  
Over-voltage safety  
protection  
CAT III 1000 V,  
CAT IV 600 V  
CAT III 1000 V,  
CAT IV 600 V  
CAT III 1000 V,  
CAT IV 600 V  
CAT III 1000 V,  
CAT IV 600 V  
General  
Logging memory  
200 points  
10,000 points  
10,000 points  
10,000 points  
Optional IR-USB and  
Bluetooth  
Optional IR-USB and  
Bluetooth  
Optional IR-USB and  
Bluetooth  
Optional IR-USB and  
Bluetooth  
Connectivity  
Operating temperature  
Altitude  
–20 to 55 °C  
3000 meters  
–20 to 55 °C  
3000 meters  
–20 to 55 °C  
3000 meters  
–40 to 55 °C  
3000 meters  
Water and dust ingress  
protection  
IP 54  
IP 54  
IP 54  
IP 54  
Up to 300 hours 4X AAA  
Alkaline  
Up to 300 hours 4X AAA  
Alkaline  
Up to 60 hours 4X AAA  
Alkaline  
Up to 100 hours 4X AAA  
Lithium  
Battery life  
Warranty  
3 years  
3 years  
3 years  
3 years  
8 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
General Specifications  
Display  
U1271A and U1272A: Liquid crystal display (LCD) (with maximum reading of 33,000 counts)  
U1273A/U1273AX: Organic LED (OLED) display (with maximum reading of 33,000 counts)  
Power consumption  
Battery type  
U1271A/U1272A: 460 mVA maximum (with backlight enabled)  
U1273A/U1273AX: 180 mVA maximum (with maximum brightness)  
4 × 1.5 V Alkaline battery (ANSI/NEDA 24A or IEC LR03), or  
4 × 1.5 V Zinc Chloride battery (ANSI/NEDA 24D or IEC R03)  
4 × 1.5 V Lithium battery (ANSI/NEDA 24LF or IEC FR03)  
Battery life  
U1271A and U1272A: 300 hours typical (based on new Alkaline batteries for DC voltage measurement)  
U1273A/U1273AX:  
Based on new Alkaline batteries for DC voltage measurement:  
30/45/60 hours typical at High/Medium/Low brightness, respectively  
Based on new Lithium batteries for DC voltage measurement:  
50/100 hours typical at High/Low brightness, respectively  
Low battery indicator will flash when the battery voltage drops:  
For non-rechargeable batteries: 4.4 V (approximately)  
For rechargeable batteries: 4.5 V (approximately)  
Fuse  
10 × 35 mm 440 mA/1000 V 30 kA fast-acting fuse  
10 × 38 mm 11 A/1000 V 30 kA fast-acting fuse  
Input impedance at off mode  
Operating environment  
1.67 kΩ (protected by positive temperature coefficient resistor)  
(U1272A, U1273A and U1273AX only)  
Operating temperature:  
U1271A/ U1272A/U1273A: –20 to 55 °C, 0% to 80% RH  
U1273AX: –40 to 55 °C, 0% to 80% RH (using Lithium batteries)  
Full accuracy up to 80% RH for temperatures up to 30 °C, decreasing linearly to  
50% RH at 55 °C  
Altitude up to 3000 meters  
Pollution degree II  
Storage compliance  
Safety compliance  
–40 to 70 °C, 0 to 80% RH  
CAN/CSA-C22.2 No. 61010-1-04  
EN/IEC 61010-1:2001  
ANSI/UL 61010-1:2004  
Measurement category  
CAT III 1000 V/CAT IV 600 V  
Commercial limits compliance with EN61326-1  
IP-54  
Electromagnetic compatibility (EMC)  
Ingress protection rating  
Temperature coefficient  
U1271A/U1272A/U1273A: 0.05 × (specified accuracy)/°C (from –20 to 18 °C, or 28 to 55 °C)  
U1273AX: 0.05 x (specified accuracy/ °C (from –40 to 18 °C, or 28 to 55 °C)  
Common Mode Rejection Ratio (CMRR)  
Normal Mode Rejection Ration (NMRR)  
Dimensions (W x H x D)  
> 120 dB at DC, 50/60 Hz ± 0.1% (1 kΩ unbalanced)  
> 60 dB at 50/60 Hz ± 0.1%  
92 × 207 × 59 mm  
Weight  
U1271A: 518 grams (with batteries)  
U1272A: 520 grams (with batteries)  
U1273A: 500 grams (with batteries)  
U1273AX: 500 grams (with batteries)  
Warranty  
Three years for product  
Three months for product’s accessories  
Calibration cycle  
One year  
9 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Specification Assumptions  
Accuracy is given as ±(% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than  
80% RH.  
AC V and AC μA/mA/A specifications are AC coupled, true RMS and are valid from 5% of range to 100% of range.  
– The crest factor may be up to 3.0 at full scale except for the 1000 V range where it is 1.5 at full scale.  
– For non-sinusoidal waveforms, add (2% reading + 2% full scale) typical, for crest factors up to 3.  
– After ZLOW voltage measurements, wait at least 20 minutes for thermal impact to cool before proceeding with any  
other measurement.  
10 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
DC specifications for U1271A, U1272A, U1273A and U1273AX  
Accuracy ± (% of reading +  
counts of least significant digit)  
Test current/  
Burden voltage  
Function  
Range  
Resolution  
U1271A  
U1272A  
0.05 + 20  
0.05 + 5  
0.05 + 5  
0.05 + 2  
0.05 + 2  
0.05 + 2  
U1273A/U1273AX  
0.05 + 20  
0.05 + 5  
30 mV  
300 mV  
3 V  
0.001 mV  
0.01 mV  
0.0001 V  
0.001 V  
0.01 V  
0.05 + 5  
0.05 + 5  
0.05 + 2  
0.05 + 2  
0.05 + 2  
0.05 + 5  
30 V  
0.05 + 2  
300 V  
1000 V  
0.05 + 2  
0.1 V  
0.05 + 2  
Voltage1  
ZLOW (low  
input  
impedance)  
enabled, ap-  
plicable for  
1000 V range  
and resolu-  
tion only  
0.1 V  
1 + 20  
1 + 20  
30 Ω  
300 Ω  
3 kΩ  
0.001 Ω  
0.01 Ω  
0.2 + 10  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.6 + 5  
1.2 + 5  
0.2 + 10  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.6 + 5  
1.2 + 5  
0.65 mA  
0.65 mA  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.6 + 5  
1.2 + 5  
2.0 +10  
0.0001 kΩ  
0.001 kΩ  
0.01 kΩ  
65 µA  
30 kΩ  
300 kΩ  
3 MΩ  
6.5 µA  
0.65 µA  
Resistance2  
0.0001 MΩ  
0.001 MΩ  
0.01 MΩ  
93 nA/10 MΩ  
93 nA/10 MΩ  
93 nA/10 MΩ  
30 MΩ  
100 MΩ  
2.0 + 10 @ < 100 MΩ  
8.0 + 10 @ > 100 MΩ  
2.0 + 10 @ < 100 MΩ  
8.0 + 10 @ > 100 MΩ  
300 MΩ  
0.01 MΩ  
93 nA/10 MΩ  
300 nS  
300 µA  
3000 µA  
30 mA  
300 mA  
3 A  
0.01 nS  
0.01 µA  
0.1 µA  
1 + 10  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.3 +10  
0.3 +10  
1 + 10  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.3 +10  
0.3 +10  
1 + 10  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.2 + 5  
0.3 +10  
0.3 +10  
93 nA/10 MΩ  
< 0.04 V/100 Ω  
< 0.4 V/100 Ω  
< 0.08 V/1 Ω  
0.001 mA  
0.01 mA  
0.0001 A  
0.001 A  
Current3  
< 1.00 V/1 Ω  
< 0.1 V/0.01 Ω  
< 0.3 V/0.01 Ω  
10 A  
Approximately  
1 to 2 mA  
3 V  
0.0001 V  
0.0001 V  
0.5 + 5  
0.5 + 5  
0.5 + 5  
0.5 + 5  
0.5 + 5  
Diode Test4  
Approximately  
0.1 to 0.3 mA  
Auto  
See notes on next page.  
11 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
Notes for DC specifications (previous page)  
1. Notes for voltage specifications:  
The accuracy of the 30 to 300 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the  
test leads).  
– For ZLOW measurements, autoranging is disabled and the multimeter’s range is set to 1000 volts in the manual ranging mode.  
2. Notes for resistance specifications:  
– Overload protection: 1000 Vrms for short circuits with < 0.3 A current.  
– Maximum open voltage is < +3.3 V.  
Built-in buzzer beeps when the resistance measured is less than 25 Ω ± 10 Ω. The multimeter can capture intermittent measure-  
ments longer than 1 ms.  
The accuracy of the 300 Ω to 3 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal  
effect (by shorting the test leads).  
U1273AX only: The accuracy for all resistance ranges is specified after the Null function is used when measuring at temperatures  
below –20 °C. The Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads).  
For the ranges of 30 MΩ and 100 MΩ, the RH is specified for < 60%.  
The accuracy for ranges < 50 nS is specified after the Null function is used on an open test lead.  
The temperature coefficient of the 100 MΩ and 300 MΩ range is 0.1 × (specified accuracy)/°C (from –40 to 18 °C or 28 to 55 °C).  
3. Notes for current specifications:  
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.  
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.  
Specification for 300 mA range: 440 mA continuous.  
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30  
seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before  
proceeding with low current measurements.  
4. Notes for diode specifications:  
– Overload protection: 1000 Vrms for short circuits with < 0.3 A current.  
– Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or  
semiconductor junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).  
– Open voltage for diode: < +3.3 V DC.  
Open voltage for Auto diode: < +2.5 V DC and > –1.0 V DC.  
12 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
AC specifications for U1271A  
Accuracy ± (% of reading + counts of least significant digit)  
Function  
Range  
Resolution  
45 Hz to  
65 Hz  
30 Hz to  
1 kHz  
1 kHz to  
5 kHz  
5 kHz to  
20 kHz  
300 mV  
3 V  
0.01 mV  
0.0001 V  
0.001 V  
0.01 V  
0.7 + 20  
0.7 + 20  
0.7 + 20  
0.7 + 20  
0.7 + 20  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
2.0 + 25  
2.0 + 25  
2.0 + 25  
2.0 + 25  
2.0 + 40  
2.0 + 40  
2.0 + 40  
30 V  
True RMS AC  
Voltage1  
300 V  
1000 V  
0.1 V  
LPF (low pass filter) enabled,  
applicable for all voltage  
ranges and resolution  
1.0 + 25 @ < 200 Hz  
5.0 + 25 @ < 440 Hz  
0.7 + 20  
Accuracy ± (% of reading + counts of least  
significant digit)  
Function  
Range  
Resolution  
Burden voltage/Shunt  
45 Hz to 2 kHz  
300 µA  
3000 µA  
30 mA  
300 mA  
3 A  
0.01 µA  
0.1 µA  
0.9 + 25  
0.9 + 25  
0.9 + 25  
0.9 + 25  
1.0 + 25  
1.0 + 25  
< 0.04 V/100 Ω  
< 0.4 V/100 Ω  
< 0.08 V/1 Ω  
< 1.00 V/1 Ω  
0.001 mA  
0.01 mA  
0.0001 A  
0.001 A  
True RMS AC  
Current2  
< 0.1 V/0.01 Ω  
< 0.3 V/0.01 Ω  
10 A  
1. Notes for voltage specifications:  
- Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.  
- Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.  
2. Notes for current specifications:  
- Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.  
- Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.  
- Specification for 300 mA range: 440 mA continuous.  
- Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds maximum. After  
measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements.  
13 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
AC specifications for U1272A/U1273A and U1273AX  
Accuracy ± (% of reading + counts of least significant digit)  
Function  
Range  
Resolution  
45 Hz to  
65 Hz  
20 Hz to  
1 kHz  
1 kHz to  
5 kHz  
5 kHz to  
20 kHz  
20 kHz to  
100 kHz  
30 mV  
300 mV  
3 V  
0.001 mV  
0.01 mV  
0.0001 V  
0.001 V  
0.01 V  
0.6 + 20  
0.6 + 20  
0.6 + 20  
0.6 + 20  
0.6 + 20  
0.6 + 20  
0.7 + 25  
0.7 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.0 + 25  
1.5 + 25  
1.5 + 25  
1.5 + 25  
1.5 + 25  
1.0 + 40  
1.0 + 40  
2.0 + 40  
2.0 + 40  
2.0 + 40  
3.5 + 40  
3.5 + 40  
3.5 + 40  
3.5 + 40  
30 V  
True RMS AC  
Voltage1  
300 V  
1000 V  
0.1 V  
1.0 + 25 @ <  
200 Hz  
5.0 + 25 @ <  
440 Hz  
LPF (low pass filter) enabled,  
applicable for all voltage  
ranges and resolution  
0.6 + 20  
2.0 + 40  
2 + 40 @ < 440  
Hz  
ZLOW 1000 V  
Accuracy ± (% of reading +  
counts of least significant digit)  
Function  
Range  
Resolution  
Burden voltage/Shunt  
45 Hz to 65 Hz  
20 Hz to 2 kHz  
300 µA  
3000 µA  
30 mA  
300 mA  
3 A  
0.01 µA  
0.1 µA  
0.6 + 25  
0.6 + 25  
0.6 + 25  
0.6 + 25  
0.8 + 25  
0.8 + 25  
0.9 + 25  
0.9 + 25  
0.9 + 25  
0.9 + 25  
1.0 + 25  
1.0 + 25  
< 0.04 V/100 Ω  
< 0.4 V/100 Ω  
< 0.08 V/1 Ω  
< 1.00 V/1 Ω  
0.001 mA  
0.01 mA  
0.0001 A  
0.001 A  
True RMS AC  
Current2  
< 0.1 V/0.01 Ω  
< 0.3 V/0.01 Ω  
10 A  
1. Notes for voltage specifications:  
- Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.  
- Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.  
- ZLOW impedance: 2 kΩ (nominal).  
- The input signal is lower than the product of 20,000,000 V×Hz.  
- For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies > 20 kHz and signal inputs < 10% of range.  
- U1273AX only: For all AC voltage ranges, the accuracy is specified at 2.5% + 25 counts when measuring below –20 °C for 20 to 45 Hz AC signals.  
2. Notes for current specifications:  
- Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.  
- Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.  
- Specification for 300 mA range: 440 mA continuous.  
- Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds maximum. After  
measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements.  
- U1273AX only: The accuracy for the 300 μA range, 3000 μA range, and 30 mA is specified after the Null function is used when measuring at temperatures  
below –20 °C. The Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads).  
- U1273AX only: For all AC current ranges, the accuracy is specified at 2.5% + 25 counts when measuring below –20 °C for 20 to 45 Hz AC signals.  
14 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
AC + DC specifications for U1272A/U1273A and U1273AX  
Accuracy ± (% of reading + counts of least significant digit)  
Function  
Range  
Resolution  
45 Hz to  
65 Hz  
20 Hz to  
1 kHz  
1 kHz to  
5 kHz  
5 kHz to  
20 kHz  
20 kHz to  
100 kHz  
30 mV  
300 mV  
3 V  
0.001 mV  
0.01 mV  
0.0001 V  
0.001 V  
0.01 V  
0.7 + 40  
0.7 + 25  
0.7 + 25  
0.7 + 25  
0.7 + 25  
0.7 + 25  
0.8 + 45  
0.8 + 30  
1.1 + 30  
1.1 + 30  
1.1 + 30  
1.1 + 30  
1.1 + 45  
1.1 + 30  
1.6 + 30  
1.6 + 30  
1.6 + 30  
1.6 + 30  
1.1 + 60  
1.1 + 45  
2.1 + 45  
2.1 + 45  
2.1 + 45  
3.6 + 60  
3.6 + 45  
3.6 + 45  
3.6 + 45  
True RMS  
AC + DC Voltage1  
30 V  
300 V  
1000 V  
0.1 V  
Accuracy ± (% of reading +  
counts of least significant digit)  
Function  
Range  
Resolution  
Burden voltage/Shunt  
45 Hz to 65 Hz  
20 Hz to 2 kHz  
300 µA  
3000 µA  
30 mA  
300 mA  
3 A  
0.01 µA  
0.1 µA  
0.8 + 30  
0.8 + 30  
0.8 + 30  
0.8 + 30  
0.9 + 35  
0.9 + 35  
1.1 + 30  
1.1 + 30  
1.1 + 30  
1.1 + 30  
1.3 + 35  
1.3 + 35  
< 0.04 V/100 Ω  
< 0.4 V/100 Ω  
< 0.08 V/1 Ω  
< 1.00 V/1 Ω  
0.001 mA  
0.01 mA  
0.0001 A  
0.001 A  
True RMS  
AC + DC Current2  
< 0.1 V/0.01 Ω  
< 0.3 V/0.01 Ω  
10 A  
1. Notes for voltage specifications:  
- Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.  
- Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.  
- For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies > 20 kHz and signal inputs < 10% of range  
- U1273AX only: For all AC+DC voltage ranges, the accuracy is specified at 2.5% + 30 counts when measuring below –20 °C for 20 to 45 Hz AC+DC signals.  
2. Notes for current specifications:  
- Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.  
- Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.  
- Specification for 300 mA range: 440 mA continuous.  
- Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds maximum. After  
measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements.  
- U1273AX only: The accuracy for the 300 μA range, 3000 μA range, and 30 mA is specified after the Null function is used when measuring at temperatures  
below –20 °C. The Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads).  
- U1273AX only: For all AC+DC current ranges, the accuracy is specified at 2.5% + 30 counts when measuring below –20 °C for 20 to 45 Hz AC+DC signals.  
15 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
Temperature specifications1 - 4  
Accuracy ± (% of reading +  
Thermocouple  
as specified below)  
Range  
Resolution  
type  
U1271A  
U1272A  
U1273A/U1273AX  
1% of reading  
+ 1 °C  
1% of reading  
+ 1 °C  
1% of reading  
+ 1 °C  
–200 to 1372 °C  
–328 to 2502 °F  
0.1 °C  
0.1 °F  
K
J
1% of reading  
+ 1.8 °F  
1% of reading  
+ 1.8 °F  
1% of reading  
+ 1.8 °F  
1% of reading  
+ 1 °C  
1% of reading  
+ 1 °C  
–210 to 1200 °C  
–346 to 2192 °F  
0.1 °C  
0.1 °F  
1% of reading  
+ 1.8 °F  
1% of reading  
+ 1.8 °F  
1. The specifications above is specified after 60 minutes of warm-up time.  
2. The accuracy does not include the tolerance of the thermocouple probe.  
3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltages pose a shock hazard.  
4. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1 and NIST175.  
Capacitance specifications5, 6  
Accuracy ± (% of reading +  
counts of least significant digit)  
Range  
Resolution  
U1271A  
1 + 5  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
U1272A  
1 + 5  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
U1273A/U1273AX  
10 nF  
100 nF  
1000 nF  
10 μF  
0.001 nF  
0.01 nF  
0.1 nF  
1 + 5  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
1 + 2  
0.001 μF  
0.01 μF  
0.1 μF  
100 μF  
1000 μF  
10 mF  
0.001 mF  
5. Overload protection: 1000 Vrms for short circuits with < 0.3 A current.  
6. The accuracy for all ranges is specified based on a film capacitor or better, and after the Null function is used to subtract the test lead resistance and ther-  
mal effect (by opening the test leads).  
16 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
Frequency specifications1, 2  
Accuracy ± (% of reading +  
counts of least significant digit)  
Range  
Resolution  
Minimum input frequency  
99.999 Hz  
999.99 Hz  
9.9999 kHz  
99.999 kHz  
999.99 kHz  
> 1 MHz  
0.001 Hz  
0.01 Hz  
0.1 Hz  
0.02 + 5  
0.005 + 5  
0.005 + 5  
0.5 Hz  
1 Hz  
0.005 + 5  
0.01 kHz  
0.1 kHz  
0.005 + 5  
0.005 + 5 @ < 1 MHz  
1. Overload protection: 1000 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency).  
2. The frequency measurement is susceptible to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise pickup is criti-  
cal for minimizing measurement errors. Turning on the low pass filter may help you to filter out the noise and achieve a stable reading.  
Duty Cycle3  
Mode  
Range  
99.99%  
99.99%  
Accuracy at full scale  
0.3 % per kHz + 0.3 %  
0.3 % per kHz + 0.3 %  
DC coupling  
AC coupling  
3. Notes for duty cycle specifications:  
- The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range. For AC couplings, the duty cycle  
range can be measured within the range of 10% to 90% for signal frequencies > 20 Hz.  
- The range of the duty cycle is determined by the frequency of the signal: {10 μs × frequency × 100%} to {[1 – (10 μs × frequency)] × 100%}.  
- The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.  
Pulse Width4  
Range  
Resolution  
0.01 ms  
0.1 ms  
Accuracy at full scale  
999.99 ms  
2000.0 ms  
(duty cycle accuracy/frequency) + 0.01 ms  
(duty cycle accuracy/frequency) + 0.1 ms  
4. Notes for pulse width specifications:  
- The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range.  
- The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.  
17 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
U1271A and U1272A frequency sensitivity for voltage measurements1, 2, 3  
Minimum sensitivity (RMS sine wave)  
Trigger level for DC coupling  
0.5 Hz to 200 kHz  
Input range  
15 Hz to  
100 kHz  
0.5 Hz to  
200 kHz  
Up to  
1 MHz  
U1271A  
U1272A  
5 mV  
30 mV  
300 mV  
3 V  
3 mV  
6 mV  
0.12 V  
0.6 V  
6 V  
3 mV  
8 mV  
40 mV  
0.4 V  
2.6 V  
10 mV  
0.15 V  
15 mV  
0.15 V  
0.2 V  
30 V  
0.8 V  
1.5 V  
1.5 V  
300 V  
1000 V  
8 V @ < 100 kHz  
50 V @ < 100 kHz  
9 V @ < 100 kHz  
90 V @ < 100 kHz  
9 V @ < 100 kHz  
90 V @ < 100 kHz  
50 V  
1. Maximum input for specified accuracy, refer to “AC specifications” on page 12.  
2. 30 mV range applicable for U1272A only.  
3. 200 kHz to 1 MHz range applicable for U1272A only.  
U1273A/U1273AX sensitivity for voltage measurements4  
Frequency sensitivity and trigger level  
Minimum sensitivity (RMS sine wave) Trigger level for DC coupling  
Input range  
Maximum input for specified  
accuracy, refer to AC voltage  
15 Hz to  
100 kHz  
0.5 Hz to  
200 kHz  
Up to  
1 MHz  
0.5 Hz to 200 kHz  
30 mV  
300 mV  
3 V  
3 mV  
7 mV  
0.12 V  
0.8 V  
6.7 V  
67 V  
3 mV  
8 mV  
38 mV  
0.48 V  
3.5 V  
5 mV  
15 mV  
0.12 V  
0.15 V  
30 V  
0.8 V  
1.5 V  
300 V  
1000 V  
8 V < 100 kHz  
67 V < 100 kHz  
11 V < 100 kHz  
110 V < 100 kHz  
4. Maximum input for specified accuracy, refer to “AC specifications” on page 13.  
Frequency sensitivity for current measurements5  
Minimum sensitivity (RMS sine wave)  
Input range  
2 Hz to 30 kHz  
U1271A/U1272A  
100 µA  
70 µA  
U1273A/U1273AX  
70 μA  
300 µA  
3000 µA  
30 mA  
300 mA  
3 A  
120 μA  
1.2 mA  
1.2 mA  
12 mA  
12 mA  
0.12 A  
0.12 A  
10 A  
1.2 A  
1.2 A  
5. Maximum input for specified accuracy, refer to “AC specifications” on page 12 and 13.  
18 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Electrical Specifications  
Peak hold  
Signal width  
Accuracy for DC Voltage and Current  
Specified accuracy + 400  
Single event >1 ms  
Repetitive >250 µs  
Specified accuracy + 1000  
Decibel (dB) for U1272A and U1273A1, 2, 3  
dB base  
Reference  
Default reference  
1 mW (dBm)  
1 V (dBV)  
1 to 9999 Ω  
50 Ω  
1 V  
1 V  
1. The reading of dBm is indicated in decibels of power above or below 1 mW, or decibels of voltage above or below 1 V. The formula is calculated according  
to the voltage measurement and specified reference impedance. Its accuracy is depended on the accuracy of the voltage measurement. See Decibel (dBV)  
accuracy table below.  
2. Auto-ranging mode is used.  
3. The bandwidth is according to voltage measurement.  
Decibel (dBV) accuracy  
dBV range  
Accuracy  
Range  
45 Hz to  
65 Hz  
20 Hz to  
1 kHz  
1 Hz to  
5 kHz  
5 kHz to  
20 kHz  
20 Hz to  
100 kHz  
Minimum  
Maximum  
30 mV  
300 mV  
3 V  
–56.48  
–36.48  
–16.48  
+3.52  
–30.46  
–10.46  
+9.54  
+29.54  
+49.54  
+60  
0.06  
0.06  
0.06  
0.06  
0.06  
0.06  
0.07  
0.07  
0.09  
0.09  
0.09  
0.09  
0.09  
0.09  
0.14  
0.14  
0.14  
0.14  
0.1  
0.1  
0.32  
0.32  
0.32  
0.32  
0.19  
0.19  
0.19  
30 V  
300 V  
1000 V  
+23.52  
+33.98  
Measurement rate (approximate)  
Times/second  
Function  
U1271A  
U1272A/U1273A/U1273AX  
ACV  
DCV  
7
7
7
7
14  
14  
Ω with offset compensation  
Diode  
-
3
14  
14  
Auto Diode  
Capacitance  
DCA  
-
3
4 (< 100 µF)  
4 (< 100 µF)  
7
7
ACA  
7
7
Temperature  
Frequency  
Duty cycle  
Pulse width  
7
7
2 (> 10 Hz)  
1 (> 10 Hz)  
1 (> 10 Hz)  
2 (> 10 Hz)  
1 (> 10 Hz)  
1 (> 10 Hz)  
19 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Ordering Information  
U1271A  
U1272A  
U1273A  
U1273AX  
Standard shipped accessories  
Standard test leads, test probes with 4-mm tips, K-type thermocouple and adapter, 4x AAA alkaline batteries (4x AAA lithium batteries for U1273AX only),  
Certificate of Calibration, UK 6 (test report), Quick Start Guide  
Optional accessories  
Measuring accessories (non-temperature)  
U1161A  
Extended test  
lead kit  
Includes two test leads (red and black), two test probes, medium-sized alligator clips  
and 4-mm banana plugs.  
Test leads: CAT III 1000 V, CAT IV 600 V, 15 A  
Test probes (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A  
Medium-sized alligator clips: CAT III 1000 V/CAT IV 600 V, 15 A  
4-mm banana plugs: CAT II 600 V, 10 A  
U1162A  
Alligator clips  
One pair of insulated alligator clips (red and black). Recommended for use with  
Keysight standard test leads.  
CAT III 1000 V, CAT IV 600 V, 15 A  
U1163A  
One pair of SMT grabbers (red and black). Recommended for use with Keysight  
SMT grabbers  
standard test leads.  
Rated CAT II 300 V, 3 A  
U1164A  
Fine-tip test  
probes  
One pair of fine-tip test probes (red and black). Recommended for use with  
Keysight standard test leads.  
Rated CAT II 300 V, 3 A  
U1168A  
Standard test  
lead kit  
Includes two test leads (red and black), 4-mm test probes, alligator clips, fine-tip test  
probes, SMT grabbers and mini grabber (black).  
Test leads: CAT III 1000 V, CAT IV 600 V, 15 A  
Test probe (19-mm tips): CAT II 1000 V, 15 A  
Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A  
(highly recommended for CAT IV environment)  
Alligator clips: CAT III 1000 V, CAT IV 600 V, 15 A  
Fine-tip test probes: CAT II 300 V, 3 A  
SMT grabber: CAT II 300 V, 3 A  
Mini grabber: CAT II 300 V, 3 A  
U1583B  
Dual range: 40 A and 400 A  
AC current clamp  
Rated CAT III 600 V  
BNC-to-banana-plug adapter provided for use with DMMs  
-40 to 55 °C operating temperature  
20 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Ordering Information  
Optional accessories  
Measuring accessories (temperature)  
U1180A  
Includes thermocouple adapter, thermocouple bead J-type and thermocouple bead  
Thermocouple  
adapter+lead kit,  
J and K types  
K-type.  
T/C adapter J/K-type  
T/C bead J-type: –20 to 200 °C  
T/C bead K-type: –20 to 200 °C  
U1181A  
Immersion tempera-  
ture probe  
Type-K T/C for use in oil and other liquids  
Measurement range: –50 to 700 ºC  
Includes adapter U1184A for connection to DMM  
U1182A  
Type-K T/C for use on still surfaces  
Industrial surface  
temperature probe  
Measurement range: –50 to 400 ºC  
Includes adapter U1184A for connection to DMM  
U1183A  
Air temperature  
probe  
Type-K T/C for use in air and non-caustic gas  
Measurement range: –50 to 800 ºC  
Includes adapter U1184A for connection to DMM  
U1184A  
Mini-connector-to-banana-plug adapter for use with DMM  
Temperature probe  
adapter  
U1185A  
T/C adapter J/K-type  
J-type thermocouple  
and adapter  
T/C bead J-type: –20 to 200 °C  
U1186A  
T/C adapter J/K-type  
K-type thermocou-  
ple and adapter  
T/C bead J-type: –20 to 200 °C  
21 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
Ordering Information  
Optional accessories  
U1171A  
For fastening the DMM to a steel surface so both hands are free  
Magnetic hanging kit  
U1173A  
IR-to-USB cable  
For remote control and data logging to PC  
Maximum baud rate: 19,200 bits per second  
U1174A  
The convenient way to carry your DMM and essential accessories  
Soft carrying case  
Dimension: 9 inches (H) x 5 inches (W) x 3 inches (D)  
U1177A  
Bluetooth Adapter  
Enables Bluetooth connection to Keysight handheld digital multimeters  
Support the U1230, U1240, U1250 and U1270 Series handheld multimeters  
Remote monitoring and data logging capabilities via Android devices or  
Windows-based PC  
Recommended to use Lithium battery in lower than -20°C in temperature for  
long hours of operation  
22 | Keysight | U1270 Series Handheld Digital Multimeters - Data Sheet  
For more information on Keysight  
From Hewlett-Packard through Agilent to Keysight  
For more than 75 years, we‘ve been helping you unlock measurement insights. Our  
unique combination of hardware, software and people can help you reach your next  
breakthrough. Unlocking measurement insights since 1939.  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
1939  
THE FUTURE  
Other AP Countries  
myKeysight  
Europe & Middle East  
Austria  
Belgium  
Finland  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
Spain  
Sweden  
Three-Year Warranty  
www.keysight.com/find/ThreeYearWarranty  
Keysight’s committed to superior product quality and lower total cost  
of ownership. Keysight is the only test and measurement company with  
three-year warranty standard on all instruments, worldwide. And, we provide  
a one-year warranty on many accessories, calibration devices, systems and  
custom products.  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure your  
instruments are operating to specification, so you can rely on accurate  
measurements.  
Switzerland  
Opt. 2 (FR)  
Opt. 3 (IT)  
United Kingdom  
0800 0260637  
Keysight Infoline  
www.keysight.com/find/service  
Keysight’s insight to best in class information management. Free access to  
your Keysight equipment company reports and e-library.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-02-10-16)  
Keysight Channel Partners  
www.keysight.com/find/channelpartners  
Get the best of both worlds: Keysight’s measurement expertise and product  
breadth, combined with channel partner convenience.  
DEKRA Certified  
ISO9001 Quality Management System  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
www.keysight.com/find/handhelddmm  
This information is subject to change without notice.  
© Keysight Technologies, 2013 - 2016  
Published in USA, May 24, 2016  
5990-6425EN  
www.keysight.com  

相关型号:

U1273AX

U1270 Series Handheld Digital Multimeters
KEYSIGHT

U12C05

POWER RECTIFIERS(12A,50-200V)
MOSPEC

U12C05_05

Switchmode Dual Ultrafast Power Rectifiers
MOSPEC

U12C10

POWER RECTIFIERS(12A,50-200V)
MOSPEC

U12C15

POWER RECTIFIERS(12A,50-200V)
MOSPEC

U12C20

POWER RECTIFIERS(12A,50-200V)
MOSPEC

U12C20A

12 Ampere Common Anode Ultra Fast Recovery Rectifier Diodes
THINKISEMI

U12C20A_18

12.0 Ampere Dual Common Anode Ultra Fast Recovery Rectifiers
THINKISEMI

U12C20C

12 Ampere Common Cathode Ultra Fast Recovery Rectifiers
THINKISEMI

U12C20C_18

12.0 Ampere Dual Common Cathode Ultra Fast Recovery Rectifiers
THINKISEMI

U12C20D

12.0 Ampere Dual Common Cathode Ultra Fast Recovery Rectifiers
THINKISEMI

U12C20S

12.0 Ampere Dual Common Cathode Ultra Fast Recovery Rectifiers
THINKISEMI