U8903A [KEYSIGHT]

M9260A PXIe Audio Analyzer Module;
U8903A
型号: U8903A
厂家: Keysight Technologies    Keysight Technologies
描述:

M9260A PXIe Audio Analyzer Module

文件: 总13页 (文件大小:1316K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Keysight Technologies  
M9260A PXIe Audio Analyzer Module  
Data Sheet  
02 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
What is an audio analyzer?  
An audio analyzer is a test and measurement instrument that is used to quantify the  
audio quality of electronic and electro-acoustical devices, including but not limited to  
the following:  
– Radio  
– Mobile phone  
Bluetooth® audio device  
– Broadcasting system  
– Home theater  
– Speaker  
– Microphone  
– ADC/DAC  
– Audio/Low-frequency amplifier  
– Automotive infotainment system  
– Hearing aid  
Typically, audio quality metrics comprise the level gain, total harmonic distortion (THD),  
total harmonic distortion plus noise (THD+N), crosstalk, relative phase of signals and  
frequency response, among others.  
The two important characteristics in the selection of an audio analyzer:  
Test speed: How fast can the audio analyzer test multiple device under tests (DUTs)  
in the production line?  
Purity of signal generation: How certain are you that the signal received by the DUT  
is the signal generated by the audio analyzer?  
The M9260A PXIe audio analyzer is not your traditional  
digitizer  
The Keysight Technologies, Inc. M9260A PXIe audio analyzer module is designed for fast,  
high-performance audio measurement, unlike traditional general-purpose digitizers.  
The M9260A build includes two audio generator channels and two audio analyzer  
channels in a single 3U height PXIe module.  
Key features that make the M9260A uniquely fast and accurate include:  
Large 1-million-sample arbitrary waveform buffer that speeds up signal  
generation  
Large 1-million-sample input buffer that speeds up signal acquisition and analysis  
Gain of 5 amplifiers that increase signal sensitivity, leading to accurate replication of  
signals to and from the DUT  
– Super-linear, low-noise analog-to-digital converters (ADC) and digital-to-analog  
converters (DAC)  
– Signal generation with ultra-low residual distortion of -106 dB and 1% amplitude  
accuracy  
Additional built-in features of the M9260A PXIe audio analyzer that make it a worthy  
investment:  
Built-in loopback system helps with self-calibration of the “generator” and  
“analyzer” blocks, hence ensuring the quality and accuracy of signal used for test  
Built-in multiple impedance selection allows convenient impedance matching to  
avoid errors due to mismatched impedances in the test system  
www.keysight.com/find/M9260A  
03 | Keysight | Power Supply Testing – Application Note  
Pure audio signal generation  
A pure or clean audio signal is defined by a signal with very low distortion and noise. One  
of the common contributors to signal distortion in traditional digitizers is phase dis-  
continuity. Traditional digitizers typically come with relatively small arbitrary waveform  
buffers that can only house a maximum of 1K to 2K samples. For complex test signals  
that exceed this capacity, usually several hundred thousand samples, the signal needs  
to be ‘chopped’ up into multiple pieces and then ‘stitched back’ together to recreate the  
entire waveform. The ‘stitching back’ is where phase discontinuity inevitably happens.  
With the M9260A PXIe audio analyzer module, you can transmit up to 1 million samples  
of signal all at once, owing to its large arbitrary waveform buffer, which avoids the issue  
of distortion due to phase discontinuity.  
Distortion in audio signal generation can also be caused by the non-linearity of output  
amplifiers. Typically, this can be resolved by using an amplifier with a higher gain. While  
a traditional digitizer module typically has only three ranges (gain of 3), the M9260A PXIe  
audio analyzer module has five, resulting in an output that’s relatively more linear and  
accurate. With the M9260A, you can achieve:  
THD+N (20 Hz to 20 kHz): –103 dB (≥ 1 Vp)  
– THD (20 Hz to 20 kHz): –106 dB  
– Amplitude accuracy: ±0.087 dB (±1%)  
High-performance audio measurement  
Leveraging the design of the high performance Keysight U8903B audio analyzer, the  
M9260A PXIe audio analyzer module provides reliable audio measurement capabilities  
that matches its pure signal generation.  
– Amplitude accuracy: ±0.58% for AC, ±1% for DC  
– Low input residual distortion and noise: –95 dB @1 kHz, 20 Hz to 20 kHz BW  
– Residual THD: –101 dB @1 kHz, 20 Hz to 20 kHz BW  
Max input amplitude: 46 Vp  
Flatness: ±0.08 dB (20 Hz to 88 kHz BW, ≤ 10 Vp)  
– Ultra-low crosstalk for multi-channel measurement: –123 dB (20 kHz BW)  
04 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
High-speed production testing  
In high-throughput production testing, speed is critical. The M9260A PXIe audio analyzer module is designed to optimize  
testing speed in two ways: fast signal generation and fast signal analysis. Figure 1 illustrates the blocks within the M9260A  
that define its unique high-throughput capability.  
Fast audio signal generation  
There are two ways for a signal to be generated by the M9260A. The first method is to have the test signal created via the  
PC software and then loaded to the M9260A arbitrary waveform buffer. The M9260A PXI module then generates the test  
signal according to the arbitrary waveform description, to the Device Under Test (DUT).  
Large 1-million-sample arbitrary waveform buffer  
Traditional digitizers typically come with relatively small arbitrary waveform buffers that can only house a maximum of 1K to  
2K samples. For complex test signals that exceed this capacity, usually several hundred thousand samples, the signal needs  
to be first ‘chopped’ up into multiple pieces, and then sequentially sent to the PXIe module. The total processing time can  
be significantly reduced with the M9260A PXIe audio analyzer module, as it comes with a large 1-million-sample arbitrary  
waveform buffer. This means you can transmit any waveform of up to 1 million samples, to the M9260A module once,  
without having to face buffer and speed limitations that are common with traditional digitizers.  
Built-in waveforms  
In addition to the large arbitrary waveform buffer, Figure 1 also shows that the M9260A PXIe audio analyzer module comes  
with built-in waveforms that speed up the signal generation process further. Commonly used waveforms that are built into  
the M9260A include the sinewave, dual-sinewave, variable-phase sinewave, DC, Gaussian noise, rectangular noise and  
pink noise. Having these waveforms built in means you do not need to generate the test signal with a PC software. All you  
need to do is send a software command to the PXIe module and indicate which of the built-in waveforms you would like to  
generate. The PXIe module then sends the signal almost immediately to the DUT, reducing significant signal generation time.  
Fast audio signal analysis  
For signal measurement, the M9260A receives the incoming test signal from the DUT, after which the signal goes through  
signal conditioning and the analog-to-digital converter before it is sent to the input buffer where the signal ‘waits’ to be  
streamed back to the PC for analysis.  
Large 1-million-sample input buffer  
As with its large arbitrary waveform buffer for signal generation, the M9260A PXIe audio analyzer has a large 1-million-sam-  
ple input buffer, which means a virtually ‘limitless’ memory for acquisition and seamless streaming to PC. This is unlike  
traditional digitizers that typically provide a smaller 1K input buffer size that limits the signal measurement capability to just  
1 thousand samples at any one time. With the M9260A module, you can achieve fast audio signal acquisition and analysis  
for high-speed production testing.  
PXI chassis  
Built-in  
waveform  
M9260A  
Arbitrary  
waveform  
buffer  
Waveform  
generation  
Device  
Under Test  
(DUT)  
Input  
Data  
buffer  
acquisition  
PC with test  
software  
Figure 1. M9260A PXIe audio analyzer signal generation and acquisition building blocks  
www.keysight.com/find/M9260A  
05 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Loopback and multiple impedance selection  
The M9260A PXIe audio analyzer module includes built-in features that aim to provide  
you with greater convenience and confidence in your audio measurement tasks. Figure 2  
illustrates the loopback and multiple impedance selection within the M9260A.  
Loopback: The M9260A module has a loopback from the generator to the analyzer. This  
enables an automatic self-test and self-calibration of the audio analyzer module. This  
avoids the need for manual calibration via an external BNC cable, which could inevitably  
introduce errors due to the external connector or cable. For automated test systems, the  
loopback is a critical feature as manual calibration via an external BNC cable is not an  
allowed procedure.  
Multiple impedance selection: Unmatched impedances can create errors in test, which is  
why it is necessary to ensure exact impedance matches to the DUT. Typical digitizers do  
not provide a selection of impedances – usually only one – hence you often need to use  
external impedance converters to achieve the required impedance. The M9260A output  
impedance selection includes the 50 impedance that’s commonly used for audio devices,  
and 600 impedance to match legacy audio devices. The M9260A input impedance in-  
cludes three selections: 50 , 600 , and 1 Mto match the output of most audio devices.  
In addition to this selection, the Keysight U8903A-109 BNC accessory kit is available if you  
need to convert the M9260A impedance to any other required value.  
Output impedance  
50Ω  
600Ω  
M9260A  
Loopback  
Generator  
Input impedance  
1MΩ  
Analyzer  
50Ω  
600Ω  
Figure 2. M9260A PXIe audio analyzer loopback and multiple impedance selection features  
www.keysight.com/find/M9260A  
06 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
The M9260A PXIe audio analyzer for your radio testing  
Keysight Radio Test Solution  
The M9260A PXIe audio analyzer module is a critical part of the Keysight Radio Test  
Solution, specifically in the audio signal generation and analysis. The Keysight Radio Test  
Solution is a combination of hardware and software building blocks in a single, scalable  
chassis, aimed at providing military, public safety, and avionics radio communication  
departments with reliable, quality RF and audio signal generation and analysis.  
More info on the Keysight Radio Test Solution: www.keysight.com/find/solution-radiotest  
Radio Test Audio Library (M9560A-1TP)  
The M9560A-1TP Radio Test Audio Library provides audio analysis software components  
(.NET classes) for Keysight Radio Test Solution. You can also use the M9560A-1TP for  
audio signal generation and analysis in usage with the M9260A PXIe audio analyzer  
module. The M9560A-1TP audio signal generation library includes pseudo-voice with  
ITU-T G227 filter and baseband audio waveforms such as single tone, dual tone and  
Gaussian noise. The M9560A-1TP audio signal analysis library includes audio spectrum  
with selectable FFT windows, audio measurement results (THD, SINAD, SNR, max  
voltage), and audio filtering (low pass, high pass, band pass and Bit Error Rate (BER).  
More info on the Keysight Radio Test Audio Library: www.keysight.com/find/M9560A  
Figure 3. M9560A-1TP software interface  
www.keysight.com/find/M9260A  
07 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Software: Drivers and Soft Front Panel (SFP)  
Included in the M9260A software installer that you can download from Keysight.com are  
the IVI-C, IVI-COM and LabVIEW G drivers. Also included in the installer is the intuitive  
M9260A PXIe module soft front panel (SFP) software that you can use to configure and  
control the PXIe module.  
SFP features:  
– Module maintenance allows self-test, module reset and firmware upgrades  
– Audio generator settings allow sine-wave generation, with amplitude frequency and DC  
offset adjustments. You can also select differential or pseudo-differential output, and  
50 or 600 output impedance.  
– Audio analyzer settings allow loopback control, and selection of differential or pseudo-  
differential input, AC or DC input coupling, and 50 , 600 or 1 Minput impedance.  
– Basic audio measurements: AC voltage, DC voltage, frequency, THD+N ratio, THD ratio,  
SINAD and SNR  
– Filter options: 20 kHz low-pass filter, 20 Hz high-pass filter, A-weight filter or no filter  
Figure 4. M9260A PXIe module soft front panel interface  
www.keysight.com/find/M9260A  
08 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Product Characteristics  
Description  
Operating environment  
Operating temperature  
Storage temperature  
Operating humidity  
Storage humidity  
0 to 55 °C  
–40 to 71 °C  
Up to 95% RH at 40 °C (non-condensing )  
Up to 90% RH at 65 °C (non-condensing )  
Up to 3000 m  
Operating altitude  
Non-operating altitude  
Up to 4600 m  
Meets or exceeds Keysight ETM requirements on class GP where  
applicable. These include EMC, ESD, shock and vibration, power  
tolerances from PXI chassis, etc.  
Other  
Form factor  
Type/dimension: PXIe, 1 slot, 3U  
1 year  
Calibration period  
Support and complies with Keysight CCE requirements for  
PXI modular: IVI-COM, IVI-C, LabVIEW  
Drivers  
Trigger - Digital  
Trigger connector  
Trigger level  
Polarity  
SMB male  
3.3 V TTL  
Rising or falling edge  
Trigger source  
Pulse width  
External trigger input (available at front panel), PXI trigger bus  
Min 10 µs  
Trigger - Analog  
Trigger connector  
Trigger level  
Polarity  
SMB male  
±full-scale  
Rising or falling edge  
24 bits  
Resolution  
www.keysight.com/find/M9260A  
09 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Performance Specifications  
The following specifications are based on performance following 30 minutes of warm-up  
time and at operating temperatures between 0 °C to 55 °C, and sample rate of 192 kS/s  
unless stated otherwise.  
Analog Generator Specifications  
Connector type  
Impedance  
BNC  
50 Ω, 600 Ω (nom)  
Differential, pseudo-differential (50 connected from  
negative input to chassis ground)  
Input configuration  
Number of output channels  
Built-in waveform  
2 channels per module  
Sine, Dual Sine, Variable Phase, Gaussian Noise,  
Rectangular Noise, Pink Noise  
Dual sine amplitude ratio  
Variable phase  
0% to 100%  
–180º to 179.99º  
Sample rate (fs)  
1.024 kS/s to 204.8 kS/s (363.8 μHz resolution)  
Arbitrary waveform buffer  
DAC resolution  
Max 1,048,576 samples/download  
24 bits  
Max output amplitude  
Output range  
10 Vp  
0.1 Vp, 0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp in 10 dB steps  
50 mA (nom)  
Max output current  
±1% (–0.087 dB to 0.086 dB)  
±0.32% (±0.028 dB) (typ)  
DC accuracy  
±1% (–0.087 dB to 0.086 dB)  
±0.4% (±0.035 dB) (typ)  
AC accuracy @1 kHz  
AC flatness (refer to 1 kHz)  
5 Hz to 20 kHz BW  
@0.1 Vp  
±0.2500% (±0.0217 dB)  
±0.1440% (±0.0125 dB) (typ)  
±0.0925% (±0.008 dB)  
±0.0560% (±0.0049 dB) (typ)  
±0.1% (±0.0087 dB)  
@0.316 Vp, 1 Vp, 3.16 Vp,  
@10 Vp  
±0.0560% (±0.0049 dB) (typ)  
±0.9250% (–0.081 dB to 0.080 dB)  
±0.64% (±0.055 dB) (typ)  
20 kHz to 80 kHz BW  
All ranges  
Residual THD+N (@1 kHz)  
20 Hz to 20 kHz BW  
@0.316 V  
< 0.0017% (<–95 dB)  
< 0.0012% (<–98.4 dB) (typ)  
< 0.0007% (<–103 dB)  
@1 Vp, 3.16 Vp, 10 Vp  
< 0.00056% (<–105 dB) (typ)  
Residual THD (@1 kHz)  
20 Hz to 20 kHz BW  
@0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp  
< 0.0005% (<–106 dB) (typ)  
< 0.00036% (<–108.9 dB) (typ)  
Frequency range (fs = 192 kS/s)  
Frequency accuracy  
5 Hz to 79.8 kHz (up to 0.416 Fs)  
±2 ppm + 100 μHz  
Note: The voltage levels indicated in the specifications are at the full-scale of each respective range.  
www.keysight.com/find/M9260A  
10 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Analog Analyzer Specifications  
Connector type  
BNC  
Impedance  
50 Ω, 600 Ω, 1 MΩ (nom)  
AC, DC  
Input coupling  
Number of input channels  
Sample rate  
2 channels per module  
1.024 kS/s to 204.8 kS/s (363.8 µHz resolution)  
Max 1,048,576 samples/acquisition  
24 bits  
Acquisition buffer  
ADC resolution  
Measurement bandwidth  
Max input amplitude  
90 kHz @ 192 kS/s (up to 0.47 SR)  
46 Vp  
0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp, 31.6 Vp, 46 Vp in 10 dB  
steps  
Input range  
Overload protection for all ranges, with overload status  
registers (each channel) that enables the software to be  
informed of the overload status  
Input protection  
±1% (–0.087 dB to 0.086 dB)  
±0.24% (±0.021 dB) (typ)  
DC accuracy  
AC accuracy  
±0.58% (±0.05 dB)  
±0.12% (±0.010 dB) (typ)  
AC flatness (ref to 1 kHz)  
10 Hz to 20 kHz BW  
@0.316 Vp  
±0.13% (±0.011 dB)  
±0.072% (±0.0062 dB) (typ)  
±0.0925% (±0.008 dB)  
±0.056% (±0.0049 dB) (typ)  
±0.8000% (0.07 dB to 0.069 dB)  
±0.32% (±0.0278 dB) (typ)  
@1 Vp, 3.16 Vp, 10 Vp  
@31.6 Vp, 46 Vp  
20 Hz to 88 kHz BW  
@0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp  
±0.9250% (0.081 dB to 0.080 dB)  
±0.520% (±0.045 dB) (typ)  
@31.6 Vp, 46 Vp  
±5.2000% (0.46 dB to 0.44 dB)  
±3% (0.26 dB to 0.257 dB) (typ)  
Residual THD+N (@1 kHz)  
20 Hz to 20 kHz BW  
@0.316 Vp  
< 0.0017% (<95 dB)  
< 0.00136%(<97 dB) (typ)  
< 0.00085% (<101 dB)  
< 0.00068% (<–103.3 dB) (typ)  
@1 Vp, 3.16 Vp, 10 Vp  
Residual THD (@1 kHz)  
20 Hz to 20 kHz BW  
@0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp  
< 0.00085% (<101 dB)  
< 0.00048% (<106 dB) (typ)  
Residual noise (@0.316 Vp)  
20 Hz to 20 kHz BW  
≤ 1.3 µVrms  
Note: The voltage levels indicated in the specifications are at the full-scale of each respective range.  
www.keysight.com/find/M9260A  
11 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Performance Characteristics  
Generator Output Characteristics  
Crosstalk  
100 Hz to 20 kHz  
@0.316 Vp, 1 Vp, 3.16 Vp, 10 Vp  
< 0.00136% (< –97.3 dB) (typ)  
SMPTE IMD  
≤ 20 kHz BW  
< 0.002% (< –94 dB) (typ)  
DFD (IEC60118 / IEC60268)  
≤ 20 kHz BW  
< 0.0008% (< –101.9 dB) (typ)  
Phase Offset  
≤ 20 kHz  
20 kHz to 80 kHz  
±2º (typ)  
±5º (typ)  
Analyzer Input Characteristics  
Crosstalk  
≤ 20 kHz  
@0.316 Vp  
@1 Vp  
@3.16 Vp, 10 Vp  
@31.6 Vp, 46 Vp  
< 0.000064% (< –123 dB) (typ)  
< 0.0000253% (< –131 dB) (typ)  
< 0.0000142% (< –136 dB) (typ)  
< 0.0000142% (< –136 dB) (typ)  
SMPTE IMD  
≤ 20 kHz BW  
< 0.0036% (< –88 dB) (typ)  
< 0.0008% (< –102 dB) (typ)  
> 70 dB (typ)  
DFD (IEC60118 / IEC60268)  
≤ 20 kHz BW  
CMRR  
≤ 20 kHz BW, ≤ 10 Vp  
Phase Accuracy (@1 Vp)  
≤ 20 kHz  
20 kHz to 90 kHz  
±0.15° (typ)  
±0.6° (typ)  
Note: The voltage levels indicated in the specifications are at the full-scale of each respective range.  
www.keysight.com/find/M9260A  
12 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
Definitions  
Specification (spec)  
The warranted performance of a calibrated instrument that has been stored for a  
minimum of 2 hours within the operating temperature range of 0º- 55ºC and after a  
30-minute warm up period. All specifications include measurement uncertainty and  
were created in compliance with ISO-17025 methods. Data published in this document  
are specifications (spec) unless otherwise noted.  
Typical (typ)  
The characteristic performance, which 80% or more of the manufactured instruments  
will meet. This data is not warranted, does not include measurement uncertainty, and is  
valid only at room temperature (approximately 23ºC).  
Nominal (nom)  
The mean or average characteristic performance, or the value of an attribute that  
is determined by design such as a connector type, connector impedance, physical  
dimension, or operating speed. This data is not warranted and is measured at room  
temperature (approximately 23ºC).  
Ordering Information  
Product Model  
M9260A-STD  
M9260A-UDF  
Optional Accessories  
U8903A-101  
Description  
PXIe audio analyzer, 2 channels  
PXIe audio analyzer for US Defense Force, 2 channels  
Description  
Male BNC to male BNC cable, 1.2 m, jade gray  
Male BNC to male RCA cable, 2 m, black  
BNC accessory kit  
U8903A-102  
U8903A-109  
M9260A-101  
Trigger cable, 1 m SMB female to BNC male, 50 Ω  
Trigger cable, 1 m SMB female to BNC female, 50 Ω  
Description  
M9260A-102  
Warranty and Service  
M9260A-1A7  
Calibration + Uncertainties + Guardbanding (not accredited)  
ANSI Z540-1-1994 calibration  
M9260A-A6J  
Related Products  
Product Model  
U8903B  
Description  
Performance audio analyzer, 2 channels  
Audio analyzer, 2 channels, discontinued on December 31, 2016  
U8903A  
www.keysight.com/find/M9260A  
13 | Keysight | M9260A PXIe Audio Analyzer Module – Data Sheet  
For more information on Keysight  
Evolving Since 1939  
Our unique combination of hardware, software, services, and people can help you  
reach your next breakthrough. We are unlocking the future of technology.  
From Hewlett-Packard to Agilent to Keysight.  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
myKeysight  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
http://www.keysight.com/find/emt_product_registration  
Register your products to get up-to-date product information and  
find warranty information.  
Other AP Countries  
Europe & Middle East  
Austria  
Belgium  
Finland  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
Keysight Services  
www.keysight.com/find/service  
Keysight Services can help from acquisition to renewal across your  
instrument’s lifecycle. Our comprehensive service offerings—one-  
stop calibration, repair, asset management, technology refresh,  
consulting, training and more—helps you improve product quality  
and lower costs.  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure  
your instruments are operating to specification, so you can rely on  
accurate measurements.  
Spain  
Sweden  
Switzerland  
Opt. 2 (FR)  
Opt. 3 (IT)  
Keysight Channel Partners  
United Kingdom  
0800 0260637  
www.keysight.com/find/channelpartners  
Get the best of both worlds: Keysight’s measurement expertise and  
product breadth, combined with channel partner convenience.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-9-7-17)  
Bluetooth® and the Bluetooth® logos are registered trademarks owned by Bluetooth SIG, Inc.,  
and any use of such marks by Keysight Technologies is under license.  
DEKRA Certified  
ISO9001 Quality Management System  
www.keysight.com/find/M9260A  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
This information is subject to change without notice.  
© Keysight Technologies, 2017  
Published in USA, December 21, 2017  
5992-1918EN  
www.keysight.com  

相关型号:

U8903A-101

M9260A PXIe Audio Analyzer Module
KEYSIGHT

U8903A-102

M9260A PXIe Audio Analyzer Module
KEYSIGHT

U8903A-109

M9260A PXIe Audio Analyzer Module
KEYSIGHT

U8903B

M9260A PXIe Audio Analyzer Module
KEYSIGHT

U891

Prescaler for TV and VTR purposes
ETC

U891BS

Prescaler for TV and VTR purposes
ETC

U891BS-FP

Prescaler for TV and VTR purposes
ETC

U893BSE

1.3 GHz Prescaler for PLL’s in TV, CATV and SAT TV Tuners
TEMIC

U893BSE-AFPG3

Prescaler/Frequency Divider
ETC

U893BSE-FP

1.3 GHz Prescaler for PLL’s in TV, CATV and SAT TV Tuners
TEMIC

U893BSE-SP

1.3 GHz Prescaler for PLL’s in TV, CATV and SAT TV Tuners
TEMIC

U89809-8000

D Type Connector, 9 Contact(s), Male, 0.109 inch Pitch, IDC Terminal, Hole .112-.124, Receptacle
3M