GEN12.5-60 [LAMBDA]
Programmable DC Power Supplies 750W/1500W; 可编程直流电源750W / 1500W型号: | GEN12.5-60 |
厂家: | DENSEI-LAMBDA |
描述: | Programmable DC Power Supplies 750W/1500W |
文件: | 总7页 (文件大小:185K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TM
The Genesys
family of programmable power supplies sets a new standard for flexible, reliable,
AC/DC power systems in OEM, Industrial and Laboratory applications.
Features include:
•Highest Power Density available 1500W in 1U
•Wide Range Input 85 - 265Vac Continuous, single phase, 47/63Hz
•Active Power Factor Correction 0.99
•Output up to 600V, Current up to 200A
•Built in RS232/RS485 Interface
•Software Calibration
•Last Setting Memory
•High Resolution 16 bits ADCs & DACs
•Reliable Encoders for Voltage and Current Adjustment
•Constant Voltage/Constant Current auto crossover
•Parallel Operation with Active Current Sharing
•Independent Remote ON/OFF and Remote Enable/Disable
•External Analog Programming and Monitoring
•Reliable Modular and SMT Design
•19" Rack Mounted ATE and OEM applications
•Five Year Warranty
•Optional Isolated Analog Programming and Monitoring
•Optional GPIB (SCPI) Interface
•LabView® drivers ( LabView® is registered trademark of National Instruments Corporation )
Worldwide Safety Agency Approvals CE Mark for LVD and EMC Regulation
Applications
Genesys™ power supplies have been designed to meet the demands of a wide variety of applications.
Test and Measurement
Last setting memory simplifies test design and requires no battery backup.
Built in RS232/RS485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming
Wide range of available inputs allows testing of many different devices.
Semiconductor Burn-in
Safe Start may be enabled to restart at zero output to protect load.
Wide range input (85-265VAC) with Active Power Factor correction rides through input transients easily.
Component Test
High power density, zero stacking and single wire parallel operation give maximum system flexibility
Laser Diode
OVP is directly set on Voltage Meter, assuring accurate protection settings.
Current Limit Fold Back assures load is protected from current surges.
Heater Supplies
Smooth, reliable encoders enhance front panel control.
Remote analog programming is user selectable 0-5V or 0-10V.
RF Amplifiers and Magnets
Robust design assures stable operation under a wide variety of loads.
Excellent linearity in voltage and current mode.
1| Genesys™ 750W/1500W-1U
Front Panel Description
1. AC On/Off
2. Air Intake allows zero stacking for maximum system flexibility and power density
3. Reliable encoder controls Output Voltage and sets Address.
4. Volt Meter shows Output Voltage and directly displays OVP, UVL and Address settings.
5. Amp Meter also displays baud rate.
6. Reliable encoder controls Output Current and sets baud rate.
7. Function/Status LED's
• Alarm
• Fine Control
• Foldback Mode
• Remote Mode
• Preview Settings • Output On
8. Pushbuttons allow flexible user configuration
Coarse and Fine Voltage and Current Adjustment of Output
Preview Settings and Set Voltage while in Current Mode or with Output OFF
Set OVP and UVL Limits
Set Current Foldback
Local/Remote Mode and select Address and Baud Rate
Output ON/OFF and Auto Start/Safe Start Mode
Rear Panel Description
1. Remote/Local Output Voltage Sense Connections
2. DIP Switches select 0-5V or 0-10V Programming and other functions.
3. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor as well as other functions.
4. RS485 Out to other Genesys Power Supplies
5. RS232/RS485 IN Remote Serial Programming
6. Output Terminals are rugged bus bars for 6-60V Output, higher output voltage models have terminal block connector.
7. Exit air assures reliable operation when zero stacked
8. Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99)
AC Input Connector 750W: IEC320, 1500W: Screw terminal Model Shown
9. Position for Optional Isolated Analog Programming or GPIB Digital Interface model shown
| 2
Genesys ™ 750W/1500W Specifications
30-50 40-38 60-25 80-19 100-15 150-10 300-5 600-2.6
750W
1500W
1.0 MODEL
GEN
6-200
6
8-180 12.5-120 20-76
X
X
X
X
X
1.Rated output voltage(*1)
V
8
12.5
20
30
40
60
80
100
150
300
600
2.Rated Output Current(*2)
3.Rated Output Power
4.Efficiency at 100/200Vac (*3)
A
W
%
200
1200
77/80
180
1440
78/81
120
1500
81/84 83/86
76
1520
50
38
25
1500
19
15
10
1500
84/88
5
2.6
1560
83/87
1500 1520
83/86 84/88 84/88 84/88 84/88
1520 1500
1500
83/87
X
1.0 MODEL
GEN
V
A
6-100
6
100
600
8-90
8
90
12.5-60 20-38
30-25 40-19 60-12.5 80-9.5 100-7.5 150-5 300-2.5 600-1.3
X
X
X
X
1.Rated output voltage (*1)
2.Rated Output Current (*2)
3.Rated Output Power
12.5
60
20
38
30
25
40
19
60
12.5
750
80
9.5
760
100
7.5
150
5
300
2.5
600
1.3
W
720
750
760
750
760
750
750
750
780
1.1 CONSTANT VOLTAGE MODE
1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4)
2.Max load regulation ( 0.01% of Vo+2mV )(*5)
3.Ripple and noise p-p 20MHz
4.Ripple r.m.s 5Hz~1MHz
5.Remote sense compensation/line
6.Temp. coefficient
7.Up-prog. response time, 0~Vomax
8.Down-prog response time full-load
9.Down-prog response time no-load
10.Transient response time (*8)
mV
mV
mV
mV
V
2.6
2.6
60
8
2.8
2.8
60
8
3.3
3.3
60
8
4
4
60
8
5
5
60
8
6
6
60
8
8
8
60
8
10
10
80
8
12
12
80
8
17
17
100
10
5
32
32
125
25
5
62
62
300
60
5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
1
1
1
1.5
2
3
4
5
PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up
mS
mS
mS
80mS , N.L/F.L , resistive load
10
500
150mS , N.L/F.L , resistive load
50
700
80
1000
150
2000
600
800
900
1100
1200 1500
2500
4000
Less than 1mSec for models up to and including 100V. 2msec for models above 100V
1.2 CONSTANT CURRENT MODE
1.Max.line regulation (0.01% of Io+ 2mA)(*4)
2.Max.load regulation (0.01% of Io+5mA)(*6)
3.Ripple r.m.s 5Hz~1MHz . (*7)
1.Max.line regulation (0.01% of Io+ 2mA)(*4)
2.Max.load regulation (0.01% of Io+5mA)(*6)
3.Ripple r.m.s 5Hz~1MHz .(*7)
mA
mA
mA
mA
mA
mA
12
15
200
2
5
400
11
14
180
2
5
360
8
11
120
2
5
240
5.8
8.8
76
2
5
152
4.5
7.5
63
2
5
125
3.9
6.9
48
2
5
95
3.25
6.25
38
2
5
75
2.95
5.95
29
2
5
57
2.75
5.75
23
2
5
45
2.5
5.5
18
2
5
35
2.25
5.25
13
2
5
25
2.13
5.13
8
2
5
X
X
X
X
X
X
X
12
4.Temp. coefficient
PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up
X
1.3 PROTECTIVE FUNCTIONS
1. OCP
2. OCP Foldback
3. OVP type
4. OVP trip point
5. Over Temp. Protection
0~105% Constant Current
Output shut down when power supply change from CV to CC. User selectable.
Inverter shut-down, manual reset by AC input recycle or by OUT button
0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V
User selectable , latched or non latched
X
X
X
X
X
X
X
X
X
X
1.4 ANALOG PROGRAMMING AND MONITORING
1.Vout Voltage Programming
2.Iout Voltage Programming
3.Vout Resistor Programming
4.Iout Resistor Programming
5.On/Off control (rear panel)
6.Output Current monitor
7.Output Voltage monitor
8.Power Supply OK signal
9. CV/CC indicator
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout.
By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic
0~5V or 0~10V , accuracy:1% , user selectable
0~5V or 0~10V ,accuracy:1% ,user selectable
5V-OK, 0V-Fail 500ohm impedance
CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.4V):10mA
Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
10. Enable/Disable
1.5 FRONT PANEL
1.Control functions
Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable)
OVP/UVL manual adjust by Volt. Adjust encoder
AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control
Address selection by Voltage (or current) adjust encoder. No of addresses:31
RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch
Baud rate selection: 1200,2400,4800,9600 and 19,200 bps
Voltage 4 digits , accuracy: 0.5%+/-1 count
Current 4 digits, accuracy: 0.5%+/-1 count
Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2.Display
3.Indications
1.6 Interface RS232&RS485 or Optional GPIB Interface
750W
X
1500W
X
Model
V
6
8
12.5
20
30
40
60
80
100
150
300
600
Remote Voltage Programming (16 bit)
Resolution (0.012% of Vomax)
Accuracy (0.05%Vomax+0.05% of Vo Actual Output)
mV
mV
0.72
6.0
0.96
8.0
1.50
12.5
2.40
20
3.60
30
4.80
40
7.2
60
9.6
80
12
100
18
150
36
300
72
600
X
X
X
X
Remote Current Programming (16 bit)
Resolution (0.012% of Iomax)
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)
Resolution (0.012% of Iomax)
mA
mA
mA
mA
12
10
24
20
10.8
9
21.6
18
7.2
6
14.4
12
4.56
3.8
9.12
7.6
3.0
2.5
6
2.28
1.9
4.56
3.8
1.50
1.25
3.0
1.14
0.95
2.28
1.9
0.90
0.75
1.80
1.50
0.60
0.5
1.20
1
0.30
0.25
0.60
0.5
0.16
0.13
0.32
0.26
X
X
X
X
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)
5
2.5
Readback Voltage
Resolution (0.012% of Vomax)
Accuracy (0.1%Vomax+0.1% of Vo Actual Output)
mV
mV
0.72
12
0.96
16
1.50
25
2.40
40
3.60
60
4.80
80
7.2
120
9.6
160
12
200
18
300
36
600
72
1200
X
X
X
X
Readback Current
Resolution (0.012% of Iomax )
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)
Resolution (0.012% of Iomax )
mA
mA
mA
mA
12
400
24
10.8
360
21.6
720
7.2
240
14.4
480
4.56
152
9.12
304
3.0
100
6
2.28
76
4.56
152
1.50
50
3.0
1.14
38
2.28
76
0.9
30
1.80
60
0.60
20
1.20
40
0.30
10
0.60
20
0.16
5.2
0.32
10.4
X
X
X
X
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)
800
200
100
OVP Programming
Resolution (0.1% of Vomax)
Accuracy (1% of Vomax)
mV
mV
6
60
8
80
12
125
20
200
29
300
39
400
59
600
78
98
146
1500
293
3000
586
6000
X
X
X
X
800 1000
*1: Minimum voltage is guaranteed to maximum 0.2% of Vomax. *3: At maximum output power.
*5: From No-load to Full-load, constant input voltage.
*2: Minimum current is guaranteed to maximum 0.4% of Iomax. *4: 85~132Vac or 170~265Vac, constant load. *6: For load voltage change, equal to the unit voltage rating, constant input voltage.
*7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current.
*8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%.
Accuracy -Values have been calculated at Vomax & Io max
3| Genesys™ 750W/1500W-1U
General Specifications Genesys™ 750W/1500W
2.1 INPUT CHARACTERISTICS
1. Input voltage/freq. (*1)
2. Power Factor
85~265Vac continuous, 47~63Hz, single phase
0.99 @100/200Vac, rated output power.
3. EN61000-3-2,3 compliance
4. Input current 100/200Vac
5. Inrush current 100/200Vac
6. Hold-up time
Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power.
750W :10.5A / 5A,
1500W :21A / 11A
750W :Less than 25A,
1500W :Less than 50A
More than 20mS , 100Vac , at 100% load.
2.2 POWER SUPPLY CONFIGURATION
1. Parallel Operation
Up to 4 units in master/slave mode with single wire current balance connection
2. Series Operation
Up to 2 units. with external diodes.
600V Max to Chassis ground
2.3 ENVIRONMENTAL CONDITIONS
1. Operating temp
2. Storage temp
0~50 °C, 100% load.
-20~70°C
3. Operating humidity
4. Storage humidity
5. Vibration
30~90% RH (no condensation).
10~95% RH (no condensation).
MIL-810E, method 514.4 , test cond. I-3.3.1 . The EUT is fixed to the vibrating surface.
Less than 20G , half sine , 11mSec. Unit is unpacked.
6. Shock
7. Altitude
Operating: 10000ft (3000m) , Non operating: 40000ft (12000m).
2.4 EMC
1.Applicable standards:
2.ESD
EN55024
IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV
IEC1000-4-4. 2KV
3.Fast transients
4.Surge immunity
5.Conducted immunity
6.Radiated immunity
7.Conducted emission
8.Radiated emission
9.Voltage dips
IEC1000-4-5. 1KV line to line, 2KV line to ground
IEC1000-4-6, 3V
IEC1000-4-3, 3V/m
EN55022B,FCC part 15J-B,VCCI-2
EN55022A,FCC part 15-A,VCCI-1
EN61000-4-11
10. Conducted emission
11. Radiated emission
EN55022B, FCC part 15-B, VCCI-2.
EN55022A, FCC part 15-A, VCCI-1.
2.5 SAFETY
1.Applicable standards:
CE Mark, UL60950,EN60950 listed. Vout<60V:Output is SELV , IEEE/Isolated analog are SELV.
60<Vout<400V: Output is hazardous, IEEE/Isolated analog are SELV.
400<Vout<600V:Output is hazardous, IEEE/Isolated analog are not SELV.
Vout<60V models :Input-Outputs (SELV): 3.0KVrms 1min, Input-Ground: 2.0KVrms 1min.
2.Withstand voltage
60<Vout<600V models: Input-Haz. Output: 2.5KVrms 1min, Input-SELV: 3KVrms 1min.
Hazardous Output.-SELV: 1.9KVrms 1min, Hazardous Output-Ground:1.9KVrms 1min.
Input-Ground: 2KVrms 1min.
3.Insulation resistance
More than 100Mohm at 25°C , 70% RH.
2.6 MECHANICAL CONSTRUCTION
1. Cooling
Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis Variable fan speed.
W: 422.8mm, H: 43.6mm, D: 432.8mm (excluding connectors, encoders, handles etc..)
2. Dimensions (WxHxD)
3. Weight
750W: 7Kg (15.4 Lbs)
1500W: 8.5Kg (18.7 Lbs)
4. AC Input connector
750W: AC Inlet IEC320.
1500W: screw terminal block, Phoenix P/N: FRONT-4-H-7.62 , with strain relief
6V to 60V models: bus-bars (hole Ø 8.5mm).
80V to 600V models :terminal block ,Phoenix P/N: FRONT-4-H-7.62
5.Output connectors
2.7 RELIABILITY SPECS
1. Warranty
5 years.
*1: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100-240Vac (50/60Hz).
Outline Drawing Genesys™ 750W/1500W Units
NOTE
1. PLUG CONNECTORS INCLUDED WITH THE POWER SUPPLY
2. CHASSIS SLIDES MOUNTING HOLES #10-32 MARKED "A"
GENERAL DEVICES P/N: CC301-00-S160 OR EQUIVALENT
| 4
Genesys™ Power Parallel and Series Configurations
Parallel operation - Master/ Slave:
Active current sharing allows up to 4 units to be connected in an auto
parallel configuration for four times the output power.
Series operation
Up to two units may be connected in series to increase the output
voltage or to provide bipolar output. (Max 600V to Chassis Ground)
Remote Programming via RS232&RS485 Interface
Standard Serial Interface allows chain control of up to 31 power
supplies on the same bus with built in RS232&485 Interface
Programming Options (Factory installed)
Digital Programming via IEEE Interface
P/N: IEEE
• IEEE 488.2 Compliant
• Program Voltage
• SCPI Compliant
• Program Current
• Measure Voltage
• Measure Current
• Over Voltage setting and shutdown
• Error and Status Messages
• Current Foldback shutdown
Isolated Analog Programming
Four Channels to Program and Monitor Voltage and Current
Isolation allows operation with floating references and difficult electrical environments.
Choose between programming with Voltage or Current.
Connection via Removable terminal block P/N: Phoenix MC1,5/8-ST-3.81
P/N: IS510 - Voltage Programming, user selectable 0-5V or 0-10V signal
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
P/N: IS420 - Current Programming with 4-20mA signal
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
5| Genesys™ 750W/1500W-1U
Power Supply Identification / Accessories
How to order
-
GEN
600
-
2.6
-
Factory Options
AC Cable option is 750W only
Region:
Series
Name
Output
Voltage
(0~600V)
Output
Current
(0~2.6A)
Option:
IEEE
IS510
IS420
E - Europe
J - Japan
I - Middle East
U- North America
Models 750/1500W
Output
Voltage
VDC
Output
Current
( A )
Output
Power
( W )
600
Output
Voltage
VDC
Output
Current
( A )
Output
Power
( W )
750
Model
Model
GEN6-100
GEN6-200
GEN8-90
0~100
0~200
0~90
GEN60-12.5
GEN60-25
GEN80-9.5
GEN80-19
GEN100-7.5
GEN100-15
GEN150-5
GEN150-10
GEN300-2.5
GEN300-5
GEN600-1.3
GEN600-2.6
0~12.5
0~25
0~9.5
0~19
0~7.5
0~15
0~5
0~6V
0~8V
1200
720
0~60V
0~80V
1500
760
GEN8-180
GEN12.5-60
GEN12.5-120
GEN20-38
GEN20-76
GEN30-25
GEN30-50
GEN40-19
GEN40-38
0~180
0~60
1440
750
1520
750
0~12.5V
0~20V
0~30V
0~40V
0~120
0~38
1500
760
0~100V
0~150V
0~300V
0~600V
1500
750
0~76
1520
750
0~10
0~2.5
0~5
1500
750
0~25
0~50
1500
760
1500
780
0~19
0~1.3
0~2.6
0~38
1520
1560
Factory option
P/N
RS232/485 Interface built in Standard
-
GPIB Interface
Voltage Programming Isolated analog interface
Current Programming Isolated analog interface
IEEE
IS510
IS420
AC Cords sets (750W only)
Region
Europe
Japan
Middle East
North America
Output Power
AC Cords
750W
750W
750W
750W
10A/250 Vac L=2m 13A/125 Vac L=2m 10A/250 Vac L=2m 13A/125 Vac L=2m
Wall Plug
INT'L 7/VII
SI-32
NEMA 5-15P
IEC320-C13
Power Supply
Connector
IEC320-C13
IEC320-C13
P/N: GEN/J
IEC320-C13
Part Number
P/N: GEN/E
P/N: GEN/I
P/N : GEN/U
Accessories
1.Communication cable
RS232/RS485 Cable is used to connect the power supply to the PC Controller
RS485
RS232
RS232
DB-25F
Mode
PC Connector
DB-9F
DB-9F
Communication Cable
Power Supply Connector
Shield Ground L=2m
EIA/TIA-568A (RJ-45)
Shield Ground L=2m
EIA/TIA-568A (RJ-45)
FShield Ground L=2m
EIA/TIA-568A (RJ-45)
P/N
GEN/485-9
GEN/232-9
GEN/232-25
Serial link cable*
Chaining Power Supply to Power Supply up to 31 GEN units
Power Supply Connector
EIA/TIA-568A (RJ-45)
Communication Cable
Shield Ground L=50cm
Mode
P/N
RS485
GEN/RJ45
* Included with the power supply
| 6